Testing a direction-dependent primordial power spectrum with observations of the cosmic microwave background

Statistical isotropy is often assumed in cosmology and should be tested rigorously against observational data. We construct simple quadratic estimators to reconstruct asymmetry in the primordial power spectrum from CMB temperature and polarization data and verify their accuracy using simulations with quadrupole power asymmetry. We show that the Planck mission, with its millions of signal-dominated modes of the temperature anisotropy, should be able to constrain the amplitude of any spherical multipole of a scale-invariant quadrupole asymmetry at the 0.01 level (2{sigma}). Almost independent constraints can be obtained from polarization at the 0.03 level after four full-sky surveys, providing an important consistency test. If the amplitude of the asymmetry is large enough, constraining its scale dependence should become possible. In scale-free quadrupole models with 1% asymmetry, consistent with the current limits from WMAP temperature data (after correction for beam asymmetries), Planck should constrain the spectral index q of power-law departures from asymmetry to {Delta}q=0.3. Finally, we show how to constrain models with axisymmetry in the same framework. For scale-free quadrupole models, Planck should constrain the direction of the asymmetry to a 1{sigma} accuracy of about 2 degrees using one year of temperature data.

72 PHYSICS OF ELEMENTARY PARTICLES AND FIELDS↗

SU-D-206-04: Iterative CBCT Scatter Shading Correction Without Prior Information

Purpose: To estimate and remove the scatter contamination in the acquired projection of cone-beam CT (CBCT), to suppress the shading artifacts and improve the image quality without prior information. Methods: The uncorrected CBCT images containing shading artifacts are reconstructed by applying the standard FDK algorithm on CBCT raw projections. The uncorrected image is then segmented to generate an initial template image. To estimate scatter signal, the differences are calculated by subtracting the simulated projections of the template image from the raw projections. Since scatter signals are dominantly continuous and low-frequency in the projection domain, they are estimated by low-pass filtering the difference signals and subtracted from the raw CBCT projections to achieve the scatter correction. Finally, the corrected CBCT image is reconstructed from the corrected projection data. Since an accurate template image is not readily segmented from the uncorrected CBCT image, the proposed scheme is iterated until the produced template is not altered. Results: The proposed scheme is evaluated on the Catphan©600 phantom data and CBCT images acquired from a pelvis patient. The result shows that shading artifacts have been effectively suppressed by the proposed method. Using multi-detector CT (MDCT) images as reference, quantitative analysis is operated to measure the quality of corrected images. Compared to images without correction, the method proposed reduces the overall CT number error from over 200 HU to be less than 50 HU and can increase the spatial uniformity. Conclusion: An iterative strategy without relying on the prior information is proposed in this work to remove the shading artifacts due to scatter contamination in the projection domain. The method is evaluated in phantom and patient studies and the result shows that the image quality is remarkably improved. The proposed method is efficient and practical to address the poor image quality issue of CBCT images. This work is supported by the Zhejiang Provincial Natural Science Foundation of China (Grant No. LR16F010001), National High-tech R&D Program for Young Scientists by the Ministry of Science and Technology of China (Grant No. 2015AA020917).

60 APPLIED LIFE SCIENCES↗

Search for $t\bar{t}H/A \rightarrow t\bar{t}t\bar{t}$ production in proton–proton collisions at $\sqrt{s}=13$ $\text {TeV}$ with the ATLAS detector

A search is presented for a heavy scalar (H) or pseudo-scalar (A) predicted by the two-Higgs-doublet models, where the H/A is produced in association with a top-quark pair $(t\bar{t}H/A),$ and with the H/A decaying into a $t\bar{t}$ pair. The full LHC Run 2 proton–proton collision data collected by the ATLAS experiment is used, corresponding to an integrated luminosity of $139~\text {fb}^{-1}.$ Events are selected requiring exactly one or two opposite-charge electrons or muons. Data-driven corrections are applied to improve the modelling of the $t\bar{t}$ +jets background in the regime with high jet and b-jet multiplicities. These include a novel multi-dimensional kinematic reweighting based on a neural network trained using data and simulations. An H/A-mass parameterised graph neural network is trained to optimise the signal-to-background discrimination. In combination with the previous search performed by the ATLAS Collaboration in the multilepton final state, the observed upper limits on the $t\bar{t}H/A \rightarrow t\bar{t}t\bar{t}$ production cross-section at 95% confidence level range between 14 fb and 5.0 fb for an H/A with mass between 400 GeV and 1000 GeV , respectively. Assuming that both the H and A contribute to the $t\bar{t}t\bar{t}$ cross-section, tan β values below 1.7 or 0.7 are excluded for a mass of 400 GeV or 1000 GeV , respectively. The results are also used to constrain a model predicting the pair production of a colour-octet scalar, with the scalar decaying into a $t\bar{t}$ pair.

72 PHYSICS OF ELEMENTARY PARTICLES AND FIELDS↗

Nucleon momentum fraction, helicity and transversity from 2+1-flavor lattice QCD

A detailed analysis of the systematic uncertainties in the calculation of the isovector momentum fraction, ( x ) u - d , helicity moment, ( x ) Δ u - Δ d , and the transversity moment, ( x ) δu - δd , of the nucleon is presented using high-statistics data on seven ensembles of gauge configurations generated by the JLab/W&M/LANL/MIT collaborations using 2 + 1-flavors of dynamical Wilson-clover quarks. The much higher statistics have facilitated better control over all systematics compared to previous lattice calculations. The least understood systematic — excited-state contamination — is quantified by studying the variation of the results as a function of different estimates of the mass gap of the first excited state, obtained from two- and three-point correlation functions, and as a function of the pion mass M π . The final results are obtained using a simultaneous fit in the lattice spacing a , pion mass M π and the finite volume parameter M π L keeping leading order corrections. The data show no significant dependence on the lattice spacing and some evidence for finite-volume corrections. Our final results, in the $ \overline{\mathrm{MS}} $ scheme at 2 GeV, are ( x ) u - d = 0 . 155(17)(20), ( x ) Δ u - Δ d = 0 . 183(14)(20) and ( x ) δu - δd = 0 . 220(18)(20), where the first error is the overall analysis uncertainty assuming excited-state contributions have been removed, and the second is an additional systematic uncertainty due to possible residual excited-state contributions. These results are consistent with phenomenological global fit values.

72 PHYSICS OF ELEMENTARY PARTICLES AND FIELDS↗

PRIME: An evaluation framework for protein representation inference and generalization in viral mutation space

Background Protein language models (PLMs) have revolutionized protein fitness prediction, yet their application to rapidly evolving viral pathogens is often confounded by extreme sequence homology. This homology leads to “data leakage” in standard random validation splits, yielding inflated performance metrics that fail to translate into real-world biosurveillance utility. Results We present Protein Representation Inference for Mutation Evaluation (PRIME), a framework that integrates domain-specific fine-tuning with a rigorous position-stratified validation protocol to evaluate viral threats. Using a dataset of 347,432 SARS-CoV-2 receptor binding domain (RBD) sequences, we demonstrate that while random training data split yields deceptive R 2 values (> 0.90), they fail to generalize to novel mutational sites. By benchmarking models up to 650 M parameters, we show that domain-specific fine-tuning of the ESM-C 600 M model with correctly stratified data provides an initial demonstration of predictive signal for binding affinity and expression at unseen mutational sites of binding affinity and expression on unseen sites (R 2 ~0.23), a significant advancement over base foundation models which exhibit no predictive power (R 2 <0). PRIME’s embedding-based clustering identified 3.03% of bat coronavirus sequences as candidates for further experimental prioritization based on their functional similarity to human-infective strains in embedding space, offering a perspective complementary to traditional phylogenetic methods. Conclusion PRIME establishes a new benchmark for the application of PLMs in pathogen surveillance. Our findings demonstrate that state-of-the-art models and fine-tuning, when paired with stratified validation, provide biologically meaningful insights into pathogen evolution and zoonotic risk.

59 BASIC BIOLOGICAL SCIENCES↗

Measurement of dijet cross-sections in pp collisions at 7 TeV centre-of-mass energy using the ATLAS detector

Double-differential dijet cross-sections measured in pp collisions at the LHC with a 7 TeV centre-of-mass energy are presented as functions of dijet mass and half the rapidity separation of the two highest-p T jets. These measurements are obtained using data corresponding to an integrated luminosity of 4.5 fb -1 , recorded by the ATLAS detector in 2011. The data are corrected for detector effects so that cross-sections are presented at the particle level. Cross-sections are measured up to 5TeV dijet mass using jets reconstructed with the anti- k t algorithm for values of the jet radius parameter of 0.4 and 0.6. The cross-sections are compared with next-to-leading-order perturbative QCD calculations by NLOJet++ corrected to account for non-perturbative effects. Comparisons with POWHEG predictions, using a next-to-leading-order matrix element calculation interfaced to a partonshower Monte Carlo simulation, are also shown. Electroweak effects are accounted for in both cases. The quantitative comparison of data and theoretical predictions obtained using various parameterizations of the parton distribution functions is performed using a frequentist method. In general, good agreement with data is observed for the NLOJet++ theoretical predictions when using the CT10, NNPDF2.1 and MSTW 2008 PDF sets. Disagreement is observed when using the ABM11 and HERAPDF1.5 PDF sets for some ranges of dijet mass and half the rapidity separation. An example setting a lower limit on the compositeness scale for a model of contact interactions is presented, showing that the unfolded results can be used to constrain contributions to dijet production beyond that predicted by the Standard Model.

72 PHYSICS OF ELEMENTARY PARTICLES AND FIELDS↗

Radiobiologic Parameters and Local Effect Model Predictions for Head-and-Neck Squamous Cell Carcinomas Exposed to High Linear Energy Transfer Ions

Purpose: To establish the radiobiologic parameters of head-and-neck squamous cell carcinomas (HNSCC) in response to ion irradiation with various linear energy transfer (LET) values and to evaluate the relevance of the local effect model (LEM) in HNSCC. Methods and Materials: Cell survival curves were established in radiosensitive SCC61 and radioresistant SQ20B cell lines irradiated with [33.6 and 184 keV/n] carbon, [302 keV/n] argon, and X-rays. The results of ion experiments were confronted to LEM predictions. Results: The relative biologic efficiency ranged from 1.5 to 4.2 for SCC61 and 2.1 to 2.8 for SQ20B cells. Fixing an arbitrary D{sub 0} parameter, which characterized survival to X-ray at high doses (>10 Gy), gave unsatisfying LEM predictions for both cell lines. For D{sub 0} = 10 Gy, the error on survival fraction at 2 Gy amounted to a factor of 10 for [184 keV/n] carbon in SCC61 cells. We showed that the slope (s{sub max}) of the survival curve at high doses was much more reliable than D{sub 0}. Fitting s{sub max} to 2.5 Gy{sup -1} gave better predictions for both cell lines. Nevertheless, LEM could not predict the responses to fast and slow ions with the same accuracy. Conclusions: The LEM could predict the main trends of these experimental data with correct orders of magnitude while s{sub max} was optimized. Thus the efficiency of carbon ions cannot be simply extracted from the clinical response of a patient to X-rays. LEM should help to optimize planning for hadrontherapy if a set of experimental data is available for high-LET radiations in various types of tumors.

62 RADIOLOGY AND NUCLEAR MEDICINE↗

Viability of the matter bounce scenario in Loop Quantum Cosmology from BICEP2 last data

The CMB map provided by the Planck project constrains the value of the ratio of tensor-to-scalar perturbations, namely r, to be smaller than 0.11 (95 % CL). This bound rules out the simplest models of inflation. However, recent data from BICEP2 is in strong tension with this constrain, as it finds a value r=0.20{sup +0.07}{sub -0.05} with 0r= disfavored at 7.0 σ, which allows these simplest inflationary models to survive. The remarkable fact is that, even though the BICEP2 experiment was conceived to search for evidence of inflation, its experimental data matches correctly theoretical results coming from the matter bounce scenario (the alternative model to the inflationary paradigm). More precisely, most bouncing cosmologies do not pass Planck's constrains due to the smallness of the value of the tensor/scalar ratio r≤ 0.11, but with new BICEP2 data some of them fit well with experimental data. This is the case with the matter bounce scenario in the teleparallel version of Loop Quantum Cosmology.

79 ASTRONOMY AND ASTROPHYSICS↗

THE VIRUS-P EXPLORATION OF NEARBY GALAXIES (VENGA): SURVEY DESIGN, DATA PROCESSING, AND SPECTRAL ANALYSIS METHODS

We present the survey design, data reduction, and spectral fitting pipeline for the VIRUS-P Exploration of Nearby Galaxies (VENGA). VENGA is an integral field spectroscopic survey, which maps the disks of 30 nearby spiral galaxies. Targets span a wide range in Hubble type, star formation activity, morphology, and inclination. The VENGA data cubes have 5.''6 FWHM spatial resolution, {approx}5 A FWHM spectral resolution, sample the 3600 A-6800 A range, and cover large areas typically sampling galaxies out to {approx}0.7R{sub 25}. These data cubes can be used to produce two-dimensional maps of the star formation rate, dust extinction, electron density, stellar population parameters, the kinematics and chemical abundances of both stars and ionized gas, and other physical quantities derived from the fitting of the stellar spectrum and the measurement of nebular emission lines. To exemplify our methods and the quality of the data, we present the VENGA data cube on the face-on Sc galaxy NGC 628 (a.k.a. M 74). The VENGA observations of NGC 628 are described, as well as the construction of the data cube, our spectral fitting method, and the fitting of the stellar and ionized gas velocity fields. We also propose a new method to measure the inclination of nearly face-on systems based on the matching of the stellar and gas rotation curves using asymmetric drift corrections. VENGA will measure relevant physical parameters across different environments within these galaxies, allowing a series of studies on star formation, structure assembly, stellar populations, chemical evolution, galactic feedback, nuclear activity, and the properties of the interstellar medium in massive disk galaxies.

79 ASTRONOMY AND ASTROPHYSICS↗

Development of a Relational-Design Database for Preservation and Analysis of Historic Measurements of Radionuclides in Soil

Between 1981 and 1986, in situ spectral gamma measurements were made from tracked vehicles as part of the Radionuclide Inventory and Distribution Program (RIDP) to document the distribution and develop inventories of 16 man-made radionuclides in surface soil from nuclear testing at the Nevada Test Site. To preserve and permit more precise geospatial and other electronic analysis of the data, the raw spectral gamma measurements (units of nanocuries/m2) were recovered from nine-track magnetic tapes, transferred to a flat-file database, and finally converted into a relational-design, desktop application in Microsoft Access 2000. To test the reliability of the measurement locations, the Nevada Grid Coordinate information was imported into Environmental Systems Research Institute (ESRI) ArcMap to compare against plots in the 1991 RIDP summary report and against known field points. The resulting RIDP Database allows users to create files of the location and concentration where each radionuclide was detected, or files of all gamma measurements associated with a particular nuclear test. Maps can be generated showing where particular radionuclides were detected. For additional analysis, datasets can be exported to a hypertext markup language (HTML) format. Extensive use has been made of RIDP data prior to development of this database. However, there have been some inconsistencies in results because of use of interim results published prior to 1991, and because some half lives used when the data was collected are different than those used today. Two major steps were taken to standardize analysis using the RIDP database. First, only spectral gamma data decay corrected to January 1, 1990 was used. Second, currently accepted half lives for the radionuclides were incorporated into an option that allows decay correction of inventory and activity values since 1990. For long-lived radionuclides, changes in inventory have been inconsequential. However, for short-lived fission products (e.g., 60Co, half life of 5.27 years), changes because of radioactive decay were found to be significant. Comparison of spectral gamma data collected in 1994 from fixed winged aircraft to RIDP shows good correlation between areas of high contaminant concentration.

54 ENVIRONMENTAL SCIENCES↗

Large-scale shell-model calculations for even-odd {sup 61-65}Fe isotopes

Large-scale shell-model calculations have been performed to calculate the negative-parity states of even-odd {sup 61-65}Fe isotopes. The results are compared with the recent experimental data reported at Legnaro National Laboratories and also with earlier calculations with fpg interaction in a truncated configuration space. It is observed that negative parity states of {sup 61}Fe can be well reproduced with GXPF1A interaction in full fp space without truncation. For {sup 63}Fe the correct ordering of levels is not reproduced. The structure of the wave function for the ground state and first excited state suggests that the ordering of the single-particle energy levels gets modified due to monopole correction.

73 NUCLEAR PHYSICS AND RADIATION PHYSICS↗

Magnetic pair distribution function data using polarized neutrons and ad hoc corrections

Here, we report the first example of magnetic pair distribution function (mPDF) data obtained through the use of neutron polarization analysis. Using the antiferromagnetic semiconductor MnTe as a test case, we present high-quality mPDF data collected on the HYSPEC instrument at the Spallation Neutron Source using longitudinal polarization analysis to isolate the magnetic scattering cross section. Clean mPDF patterns are obtained for MnTe in both the magnetically ordered state and the correlated paramagnet state, where only short-range magnetic order is present. We also demonstrate significant improvement in the quality of high-resolution mPDF data through the application of ad hoc corrections that require only minimal human input, minimizing potential sources of error in the data processing procedure. We briefly discuss the current limitations and future outlook of mPDF analysis using polarized neutrons. Overall, this work provides a useful benchmark for mPDF analysis using polarized neutrons and provides an encouraging picture of the potential for routine collection of high-quality mPDF data.

72 PHYSICS OF ELEMENTARY PARTICLES AND FIELDS↗

A Method to Extract Soiling Loss Data from Soiling Stations with Imperfect Cleaning Schedules: Preprint

Typical PV soiling stations determine the natural soiling losses by comparing the output of a naturally soiled PV cell to that of a PV cell maintained in the clean state. Inadequate cleaning frequency or human error provides opportunity for the cleaned cell to soil, directly resulting in error in the reported soiling ratio. This work investigates an algorithm to automatically detect and correct the data stream for errors associated with soiling of the clean cell. The methodology is tested on several soiling stations with irregular cleaning schedules as well as a soiling station where both ideal and imperfect cleaning schedules are in place. The initial results show that the algorithm can reduce error associated with imperfect cleaning but also confirms the benefits of maintaining an optimal cleaning schedule.

14 SOLAR ENERGY↗

The Effects of Radiation and Emitted Light Transport on the Positional Response of 11 cm × 42.5 cm × 5.5 cm NaI(Tl) Detectors

Experiments were performed with 30 11 cm x 42.5 x cm 5.5 cm NaI(Tl) detectors to better understand their positional response. Spectra were collected using 0.02 to 0.15 MBq point sources of 241 Am, 137 Cs, 60 Co, and 133 Ba positioned on lines parallel and perpendicular to the long axis of the crystal along both the narrow and wide detector faces as well as at different distances from them. A greater density of positions was sampled at the ends of the detector, and repeated measurements were made to examine potential gain drifts during the experiment. Spectroscopic peak counts, spectroscopic pulse heights, and net counts were analyzed. Empirical equations were fit to the aforementioned data for each specific source energy as a function of source position. In addition, a Monte Carlo radiation transport code was used to simulate the expected positionally variable response based solely upon radiation absorption. The simulated radiation transport efficiency functions were compared to the experimental data. The effects of the geometric radiation efficiency, the attenuation and scattering of emitted light within the scintillation crystal, and combined effects such as non-uniformity of the photomultiplier tube photocathode response and crystal irregularities were then distinguished. Functions describing each effect were derived. The results suggest potential new corrections to data obtained with large scintillation detectors as well as a novel approach to partial positional gamma-ray detection with minimal collimation, given that the energy resolution is within reason for particular photopeaks.

62 RADIOLOGY AND NUCLEAR MEDICINE↗

Design and performance testing of a novel far field Gamma system to assay radioactive waste in 400 and 200 litre drums - 15339

A Far Field Gamma ray Measurement system has been developed for measuring and assaying both 400 and 200 litre waste drums with a wide range of activity at nuclear power stations. These include radioactive waste drums with surface dose-rates of less than 2 mSv/h (200 mrem/h) and, at the higher range of activity, 400 litre drums with surface dose-rates of up to 50 mSv/h (5 rem/h). The assay system incorporates an electro-mechanically cooled high purity Germanium profile detector and advanced digital spectroscopic analysis electronics. A novel optimised conical-trapezoidal collimator has been incorporated to reduce the effect of the radioactive background in addition to the conventional detector lead shield with tin and copper graded lining to reduce the effect of lead X-rays. Two features have been incorporated to reduce detector dead time and maintain detector resolution when measuring high activity drums. The first is the inclusion of two automated tungsten filters of different thickness as an integral part of the detector collimator. The filters are used in conjunction with an automated rail system on which the detector platform is mounted. The detector can be positioned at different distances from the drum surface in order to reduce detector dead time. The deployment of the filters and the adjustment of the drum - detector position are automatically controlled based on a user defined dose-rate limit table. The data is provided by two Geiger-Muller dose-rate detectors, which are used to measure the drum surface dose-rate. This data is subsequently used to adjust the detector position and in cases of higher dose-rate deploy one or other of the tungsten filters. The drum rotation platform incorporates a load cell to determine drum weight and hence the drum density. This information is used to calculate an attenuation correction based on the assumption of uniform drum density and uniform distribution of activity within the drum. Where the waste drums have a more complicated and known regular internal structure, such as a small radioactive region surrounded by an annulus of shielding material, the analysis algorithms incorporated into the far field geometry and attenuation correction spectroscopic data analysis code are able to make a more accurate determination of drum activity than would be possible assuming a completely uniform drum. The detector energy and efficiency calibration is achieved using a point source with multiple gamma ray energy peaks. The response of the high purity Germanium detector is also modelled using the Monte Carlo Neutron Photon code and the model is benchmarked using the measured point source calibration data. The performance of the instrument has been determined for a range of uniform density matrix drums containing a set of Eu-152 line or rod sources located in re-entrant tubes positioned on an equal volume basis. When rotated, the test drums with volume distributed line sources simulate waste drums of different density each with a uniformly distributed radioactive source. The measurements have been validated using Monte Carlo simulations. (authors)

12 MANAGEMENT OF RADIOACTIVE AND NON-RADIOACTIVE W↗

Phase curves of the Kepler-11 multi-planet system

The Kepler mission has allowed the detection of numerous multi-planet exosystems where the planetary orbits are relatively compact. The first such system detected was Kepler-11 which has six known planets at the present time. These kinds of systems offer unique opportunities to study constraints on planetary albedos by taking advantage of both the precision timing and photometry provided by Kepler data to monitor possible phase variations. Here we present a case study of the Kepler-11 system in which we investigate the phase modulation of the system as the planets orbit the host star. We provide predictions of maximum phase modulation where the planets are simultaneously close to superior conjunction. We use corrected Kepler data for Q1-Q17 to determine the significance of these phase peaks. We find that data quarters where maximum phase peaks occur are better fit by a phase model than a 'null hypothesis' model.

79 ASTRONOMY AND ASTROPHYSICS↗

Resolving root causes of experiment discrepancies guided by machine learning

Abstract Scientists rely on accurate experimental data to explain nature and then harness this knowledge for applications addressing human needs. However, discrepancies between experiments of the same observable can impede scientific progress if one does not understand the underlying causes. Here, we developed a process that unravels data discrepancies by first using Bayesian machine learning to relate discrepancies to few of many, potentially biasing metadata features that encode experiment procedures. This machine learning output guides human experts to study discrepancy causes by simulating suspicious aspects of historical experiments or designing modern ones to address open questions. The study findings then lead to rejecting or correcting historical data on firm scientific bases. This process is demonstrated for the energy spectrum of neutrons emitted promptly (<1 ns) after fission of 252 Cf, a trusted nuclear physics Standard. It reduces the spread in experimental 252 Cf spectra by up to a factor of 6.

Neudecker, D. (ORCID:0000000339200627)↗