Engineering Papers⌕ Search

SEARCH · Engineering Papers

Results for “core facility location”

Search indexed NASA NTRS and DOE OSTI research on propulsion, heat transfer, battery materials and energy systems. Follow report and document links to the original sources.

Quote a phrase for an exact phrase match. Source license links do not imply unrestricted reuse.

421 records · Page 24

Production of an impermeable composite of irradiated graphite and glass by hot isostatic pressing as a long term leach resistant waste form

Around 250,000 tons of irradiated graphite (i-graphite) exists worldwide and can be considered as a current waste or future waste stream. The largest national i-graphite inventory is located in UK (∼ 100,000 tons) with significant quantities also in Russia and France [5]. Most of the i-graphite remains in the cores of shutdown nuclear reactors including the MAGNOX type in UK and the UNGG in France. Whilst there are still operational power reactors with graphite cores, such as the Russian RBMKs and the AGRs in UK, all of them will reach their end of life during the next two decades. The most common reference waste management option of i-graphite is a wet or dry retrieval of the graphite blocks from the reactor core and the grouting of these blocks in a container without further conditioning. This produces large waste package volumes because the encapsulation capacity of the grout is limited and large cavities in the graphite blocks could reduce the packing densities. Packing densities from 0.5 to 1 tons per cubic meter have been assumed for grouting solutions. Furthermore the grout is permeable. This could over time allow the penetration of aqueous phases into the waste block and a potential dissolution and release of radionuclides. As a result particularly highly soluble radionuclides may not be retained by the grout. Vitrification could present an alternative, however a similar waste package volume increase may be expected since the encapsulation capacity of glass is potentially similar to or worse than that of grout. FNAG has developed a process for the production of a graphite-glass composite material called Impermeable Graphite Matrix (IGM) [3]. This process is also applicable to irradiated graphite which allows the manufacturing of an impermeable material without volume increase. Crushed i-graphite is mixed with 20 vol.% of glass and then pressed under vacuum at an elevated temperature in an axial hot vacuum press (HVP). The obtained product has zero or negligible porosity and a water impermeable structure. Structural analysis shows that the glass in the composite has replaced the pores in the graphite structure. The typical pore volume of a graphite material is in the range of 20 vol.%. Therefore no volume increase will occur in comparison with the former graphite material. This IGM material will allow the encapsulation of graphite with package densities larger than 1.5 ton per cubic meter. Therefore a huge volume saving can be achieved by such an alternative encapsulation method. Disposal performance is also enhanced since little or no leaching of radionuclides is observed due to the impermeability of the material NNL and FNAG have proved that IGM can be produced by hot isostatic pressing (HIP) which has several advantages for radioactive materials over the HVP process. - The sealed HIP container avoids the release of any radionuclides. - The outside of the waste package is not contaminated. - The HIP process time is shorter than the HVP process time. The isostatic press avoids anisotropic density distributions. - Simple filling of the HIP container has advantages over the filling of an axial die. (authors)

12 MANAGEMENT OF RADIOACTIVE AND NON-RADIOACTIVE W↗

Andra's strategy and approach for operational safety of French underground facility Cigeo - 15127

According to the French Act on radioactive waste of 28 June 2006, Andra shall design a reversible repository. In response to this demand, Andra is developing the industrial project namely 'Cigeo', a reversible geological disposal facility for HLW and ILW located in Meuse/Haute-Marne. The previous safety cases of 2005, 2009 and 2012 give a sound basis to assess Cigeo's safety both for the operational and post-closure periods. Regarding operational safety, in this new stage of the project, the challenging issues for the preparation of the safety case are the following: - To adapt the various regulatory frameworks (nuclear and non-nuclear) to the underground facility - To design the underground facility and handling equipment's to reduce at first risks in the underground facility as such radioactive particles release, gas explosion, fire and co-activity and limit their consequence. - To establish waste acceptance criteria to be fulfilled by waste producers in line with operational safety and design options. The objective of the paper is to present the experience of Andra in operation safety of the underground facility of Cigeo. Operational safety for Cigeo is assessed as much as possible according to the existing French regulations and guidance for nuclear facilities. Indeed, compared to existing nuclear facilities, a geological repository is a specific case due to the existence of underground facilities with particularities such as: - ventilation management in a large scale underground facility, - fire risk management. As an input for the industrial design of Cigeo for operation, Andra defined a fire guidance and a specific reference safety guidance, based on the adaptation of the French nuclear regulatory texts for and when feasible to mines and tunnels regulatory texts and on its own experience gained through safety operational reports since 2005 and their reviews by the Safety Authority. - underground co-activity of nuclear operation with construction works. According to the common 'defense-in depth' principle for nuclear facilities, these guidelines for the industrial design of Cigeo for operation consider the successive levels of defense of: - Preventing the risk and its spreading by design and construction; - Detecting incidents and early fighting by design and operation dispositions (detection and control systems, survey procedure); - Controlling incidents and limiting of their consequences by safeguarding systems, specific procedures. At that stage, design options for Cigeo constitute an adequate response to the operational safety functions and requirements: - Two levels of containment are set up: the first one is ensured by the waste package, the second one is ensured from the surface facility to the disposal vaults by the transfer cask during the transfer of waste packages in the disposal vaults by the disposal vault itself and a nuclear ventilation with HEPA filter; - Favorable options for fire risk prevention and mitigation: transport system minimizing heat load (cable car for the transfer from the surface, electric transfer engines), twin access tunnels to ease fire-fighting and evacuation...; - Permanent complete physical separation of nuclear zone and construction zone (including ventilation systems). In practice, operation safety assessment of Cigeo, designed following the aforesaid reference safety guidelines, follows a common risk analysis (internal aggressions such as auxiliary losses, chemical and toxic risks, fall or collision, fire, human factors and external aggressions such as earthquake, air traffic, flooding) with the following steps: - Identification of the major risks and the design basis scenarios that have to be considered for dimensioning of the installations and the safety devices; - On the basis of these different situations, those who will have to be quantified are identified; one or more representative and envelop situations are chosen in order to evaluate robustness of the installation. Quantitative evaluation of these situations permits to: - identify the consequences on man, environment and installation, and in particular to gain confidence in the maintaining of the safety functions; - identify or define the technic and/or organisational dispositions classified as 'important elements for protection' (IEP); - Situations beyond dimensioning permit to verify the robustness of the installation. They permit, on one hand to identify possible complementary material or organisational dispositions; on the other hand, to define the 'hard core' i.e. structures, systems and components that permit to maintain the confinement function of radioactive substance. (authors)

12 MANAGEMENT OF RADIOACTIVE AND NON-RADIOACTIVE W↗

RANGE AND DISTRIBUTION OF TECHNETIUM KD VALUES IN THE SRS SUBSURFACE ENVIRONMENT

Performance assessments (PAs) are risk calculations used to estimate the amount of low-level radioactive waste that can be disposed at DOE sites. Distribution coefficients (K{sub d} values) are input parameters used in PA calculations to provide a measure of radionuclide sorption to sediment; the greater the K{sub d} value, the greater the sorption and the slower the estimated movement of the radionuclide through sediment. Understanding and quantifying K{sub d} value variability is important for estimating the uncertainty of PA calculations. Without this information, it is necessary to make overly conservative estimates about the possible limits of K{sub d} values, which in turn may increase disposal costs. Finally, technetium is commonly found to be amongst the radionuclides posing potential risk at waste disposal locations because it is believed to be highly mobile in its anionic form (pertechnetate, TcO{sub 4}{sup -}), it exists in relatively high concentrations in SRS waste, and it has a long half-life (213,000 years). The objectives of this laboratory study were to determine under SRS environmental conditions: (1) whether and to what extent TcO{sub 4}{sup -} sorbs to sediments, (2) the range of Tc K{sub d} values, (3) the distribution (normal or log-normal) of Tc K{sub d} values, and (4) how strongly Tc sorbs to SRS sediments through desorption experiments. Objective 3, to identify the Tc K{sub d} distribution is important because it provides a statistical description that influences stochastic modeling of estimated risk. The approach taken was to collect 26 sediments from a non-radioactive containing sediment core collected from E-Area, measure Tc K{sub d} values and then perform statistical analysis to describe the measured Tc K{sub d} values. The mean K{sub d} value was 3.4 {+-} 0.5 mL/g and ranged from -2.9 to 11.2 mL/g. The data did not have a Normal distribution (as defined by the Shapiro-Wilk's Statistic) and had a 95-percentile range of 2.4 to 4.4 mL/g. The E-Area subsurface is subdivided into three hydrostratigraphic layers: Upper Vadose Zone (11 to 30 ft depth), Lower Vadose Zone (30 to 51 ft depth), and aquifer (51 to 95 ft depth). The Upper Vadose Zone generally contains more clay than the Lower Vadose Zone, and the Aquifer tends to be made up of mostly sand layers with clay strata. The mean K{sub d} values of each of these zones did not differ significantly and the K{sub d} values from each zone were not from the Normal distribution. The ranges of values were greatest in the Upper Vadose Zone and least in the Lower Vadose Zone. Previous Best Estimate Tc K{sub d} values for Sandy Sediment and Clayey Sediment were 0.1 and 0.2 mL/g, respectively (Kaplan 2007a). A more thorough review indicates that the Best Estimates for Sandy Sediment is 0.1 mL/g and for Clayey Sediment is 0.8 mL/g (Kaplan 2007b). This current dataset greatly increases the number of Tc K{sub d} values measured with SRS sediments, but perhaps more importantly, provides a better estimate for E-Area sediments, and provides a measure of Tc K{sub d} distributions. Based on this dataset, the best overall Tc K{sub d} value for E-Area is the mean, 3.4 mL/g, with a log-normal distribution between the 95 percentile values of 2.4 to 4.4 mL/g. This document version differs from the earlier version, SRNS-STI-2008-00286, in that it includes some editorial corrections. This version does not contain any technical changes or changes to the conclusions presented in the earlier version.

12 MANAGEMENT OF RADIOACTIVE AND NON-RADIOACTIVE W↗

Review of the Oak Ridge National Laboratory (ORNL) Neutronic Calculations Regarding the Conversion of the High Flux Isotope Reactor (HFIR) to the Use of Low Enriched Uranium (LEU) Fuel

In awareness of the risk caused by the proliferation of nuclear materials, the international community initiated in 1978 the Reduced Enrichment for Research and Test Reactors (RERTR) Program. The goal of the RERTR program is to seek solutions to convert the reactors using High Enriched Uranium (HEU) fuel ( 235 U/U ≥ 20 wt. %) to the use of Low Enriched Uranium (LEU) Fuel ( 235 U/U < 20 wt. %). Among the 200 reactors worldwide currently in the scope of the program, about 70 have been converted or shut down prior to conversion. In the U.S., six high reactors remain to be converted. One of the U.S. reactors is the High Flux Isotope Reactor (HFIR) located at Oak Ridge National Laboratory (ORNL). This multipurpose reactor is mainly used for neutron scattering experiments and isotope production. It has two fuel elements made of involute-shaped fuel plates. The ORNL Research Reactor Division (RRD) has prepared during FY2011 two series of calculations, one neutronic and one thermal-hydraulic (TH), in support of the conversion activities for HFIR. The neutronic calculations cover mainly the evaluation of the matrix of performance (cycle length and flux), the distribution of power in the fuel elements, kinetics parameters and reactivity coefficients. As defined by the RRD procedures, the calculations have to be reviewed. Per internal decision, the RRD proposed an external reviewer, Argonne National Laboratory (ANL). The results of the Argonne neutronic review are presented in this report. The results of the TH review are presented in a separate report. The main conclusion of the ORNL reactor physics analyses is that the proposed reference HFIR LEU core (using the so-called monolithic UMo fuel) could maintain the current level of performance (obtained with a HEU core at 85MW) if it is operated at 100MW. However, to operate within the same safety limits as the current HEU core, the thermal hydraulic analyses show that the peaking of the power distribution occurring at the bottom of the fuel plates has to be reduced. The RRD has found a potential solution by reducing the fuel thickness at the bottom of the fuel plate. This would require addition of an axial grading to the already radially-graded fuel. Thus, the review has been focused on independently recalculating all of the ORNL calculations and making an as fair as possible comparison between the current 85MW HEU core and the reference 100MW LEU core design. ORNL and ANL have used the same computational tools to perform the work. The codes MCNP and ORIGEN have been used to perform the steady state and depletion calculations, respectively. The communication between the two codes has been carried out by the code VESTA. Even though the code MCNP is able to handle complex geometries, it cannot model the involute shape. Nonetheless, ANL has developed an innovative methodology to model the involute shape with MCNP with an approximation that can be made as accurate as desired. Thus, ANL has been able to perform the calculations using an explicit (or discrete) description of the fuel elements. The current modeling used by ORNL consists in homogenizing the different fuel element components (cladding, fuel, coolant…). Although this method is easier to implement, it may also affect the reactor physics which may have an impact on the calculated results. Even though some differences in the physics parameters (flux for instance) have been detected between the HEU explicit (ANL) and homogenized (ORNL) models, they are small enough to not significantly impact the performance parameters. However, this is not the case for the LEU core where the differences in the physics parameters lead to significant differences in the performance parameters, especially the cycle length (found to be considerably longer in the explicit model). Nonetheless, the others parameters calculated by ANL (power distribution, kinetics parameters…) are in good agreement with those calculated by ORNL. Some inconsistencies have been detected in the original ORNL inputs that have been corrected in the reference ones used by ANL for the review and, therefore, the cycle length difference between the LEU homogenized and explicit models has been amplified. Consequently, the ANL comparison of the HFIR HEU and LEU cores has given different results than the ORNL results. The ORNL matrix of performance for the 100MW LEU reference design shows that the reactor cycle length would be as long and the flux as high as the current 85MW HEU core. In contrast, the ANL matrix of performance shows that the 100MW LEU design would have a significantly longer cycle length (~33days) than the current 85MW HEU core (~25days). In addition, it has been shown that, if the reactor is operated for 33days, the neutron fluence would be high enough to increase the overall reactor performance by a significant factor. If the reactor is forced to shut down after 25days, calculations show that the neutron flux would be high enough to maintain the performance of the neutron scattering experiments but losses are predicted to occur in several irradiation facilities. Increasing the cycle length may not be possible for other reasons. For instance, a longer cycle length can increase the cumulative oxide layer thickness growth on the plate. The increase in the neutron fluence may affect the lifetime of the reactor vessel and, by reducing the time for maintenance, pose operational challenges. An assessment of these as well as other potential questions associated with a 33 day cycle length is needed. Since such an assessment has not been carried out, ANL cannot conclude that the ORNL reference LEU core should or could operate at 100MW. The conclusions of the ANL review are different than those of the ORNL investigation mainly because the explicit and homogenized methodologies used to model the core are different. In this report, an attempt is made to justify and explain as clearly as possible why the ANL methodology is thought to be better suited for HFIR analyses. It is acknowledged that because the ANL and ORNL LEU models have not been benchmarked against experiments, it is possible that doubts could be raised concerning the ability of the models to correctly capture all of the physics behavior of the reactor.

Bergeron, A.↗

Spectral Induced Polarization-Biogeochemical Relationships for Remediation Amendment Monitoring

Geophysical tools such as electrical resistivity (ER) can indirectly monitor subsurface changes in response to remedial injections. These methods exhibit relatively low spatial resolution compared to sediment core characterization but are advantageous due to the ability to collect measurements non-intrusively over time across large volumes of the subsurface. Moreover, along with confirmatory groundwater or core sampling, geophysical methods can be used during active biogeochemical remedies to monitor short-term contaminant transformations and mobility, as well as part of an overall strategy for long-term monitoring of subsurface contaminated sites. The use of alternating current spectral induced polarization (SIP) provides significantly more information than conventional geophysical methods like direct current ER. SIP allows for monitoring changes in both solution and surface conductivity by separation of real and imaginary conductivity, respectively, as well as surface capacitance. In principle, SIP can measure indicators of remedy progression such as precipitation reactions that sequester contaminants, potentially providing a better indication of amendment delivery and reactivity as compared to conventional ER methods. However, multiple processes and material properties have overlapping (interacting) electrical responses across a range of frequencies. Hence, the purpose of this scoping study was to evaluate if SIP can be used to monitor (a) amendment delivery and (b) precipitation and reactivity of amendments under consideration at Hanford. SIP measurements were collected in fully saturated columns packed with sand and Hanford formation sediments containing (a) amendments that were highly conductive with significant capacitance (zero valent iron – ZVI, sulfur modified iron – SMI) and (b) amendments that exhibited low electrical conductivity with a small capacitance (calcite, apatite, bismuth). The sand was a quartz material with homogenous particle size that exhibited a relatively low surface conductivity. It was used as a control for comparison with the sediments from the Hanford Site, which have a greater surface conductivity because of their complex mineralogy and heterogeneous particle size distribution and may have complex interactions with amendments. The amendment mass fraction was varied to represent the different stages and subsurface locations associated with the delivery of a remedy. The primary objective was to identify the solution and solid surface changes associated with the delivery amendments and their secondary reactions within the subsurface. The figure below summarizes results for the amendments tested through this project. The SIP phase shift or imaginary conductivity change for the high conductivity amendments was more than 10 times that of the low conductivity amendments, highlighting the relative ease of detection of ZVI and SMI independent of the background signal from sand or Hanford sediments. The ZVI phase shift and imaginary conductivity changes occur primarily at high frequency (> 100 Hz) whereas SMI changes were at low frequency (0.01 to 10 Hz). SIP signals of SMI also increased over time and the maximum shifted to lower frequencies. The low conductivity amendments (calcite, abiotic and biotic apatite, bismuth subnitrate) exhibited relatively small phase and imaginary conductivity changes when added to sediments. The changes were above minimum detection limits (0.5 mrad for phase shift, 0.03 µS/cm for imaginary conductivity) for the highest concentration except for the commercial bismuth material. The lowest amendment concentration that can be detected is likely sediment specific, as minerals in sediments (clays, magnetite, Fe-oxides) have some capacitance and, therefore, exhibit a variable phase shift.

12 MANAGEMENT OF RADIOACTIVE AND NON-RADIOACTIVE W↗

The influence of humic acid and colloidal silica on the sorption of U(VI) onto SRS Sediments Collected from the F/H Area - 15499

Between 1955 and 1988, the F/H Area Seepage Basins located in the center of SRS received approximately 6,814,000 m{sup 3} of acidic waste solutions containing radionuclides and dissolved metals. Uranium (VI) is a key contaminant of concern in groundwater associated with the basins. The pump-and-treat water treatment unit designed and built in 1997 to remove metals and radionuclides eventually became less effective, prompting research for new remedial alternatives. The pump-and-treat system was discontinued in 2004, replaced with a funnel-and-gate system in which base solutions are injected at the gates to raise pH. To take advantage of the potential formation of uranium silicate minerals, Florida International University - Applied Research Center (FIU-ARC), in collaboration with Savannah River National Laboratory (SRNL), is conducting an investigation into a base containing sodium silicate to evaluate whether these solutions have sufficient alkalinity to correct the acidic nature of the aquifer sediments. The research was extended to investigate if U(VI) is bound to colloidal silica and if any synergy exists between humic acid (HA) and colloidal Si that would influence the removal of uranium. Humic substances (HS) are a major component of soil organic matter and are known for their abilities to influence the migration behavior and fate of heavy metals. Studies showed that HA function as an important ion exchange and metal-complexing ligand, carrying a large number of functional groups with high complexing capacity that can greatly affect the mobility behavior of actinides in natural systems. The study investigates if there are any synergistic interactions between U(VI) ions, humic acid and colloidal silica under oxidized conditions and studies the influence of HA and Si on the sorption of U(VI) onto sediments collected from the F/H Area. The experiments also evaluated the effects of different environmental variables such as pH, presence of U(VI) and varying concentrations of HA on the sorption behavior of U(VI) in multi-component batch systems in the pH range between 3 and 8. Several background sediment samples were collected at SRS from archived cores obtained during installation of the well FSB 91C and used for preparation of triplicate samples. The experimental matrix was set up as follows: - Batch 1: Si (3.5 mM) + U (VI) (0.5 ppm) (no sediments and no HA); - Batch 2: Si (3.5 mM) + U (VI) (0.5 ppm) + HA (10 ppm) (no sediments); - Batch 3: U (VI) (0.5 ppm) + HA (10 ppm) (no Si and no sediments); - Batch 4: Sediments + Si (3.5 mM) + U (VI) (0.5 ppm) (no HA); - Batch 5: Sediments + Si (3.5 mM) + U (VI) (0.5 ppm) + HA; - Batch 6: Sediments + U (VI) (0.5 ppm) + HA, (no Si); - Batch 7: Sediments + U (VI) (0.5 ppm) (no Si and no HA). All samples were prepared in triplicate 50-mL conical tubes. All control and experimental tubes were vortexed and kept on a shaker for 24 h at 100 rpm and room temperature. Results showed that the sediment-bearing batches typically exceeded the performance of non-sediment batches. Results showed that the sorption of U(VI) onto sediments was influenced by the pH and the presence of HA. At low pH 3, the addition of HA slightly enhances U(VI) sorption compared to the HA-free samples. This result is consistent with other studies; in the acidic pH range, the addition of HA slightly enhances U(VI) sorption relative to the HA-free system. Conversely, in the pH range of 4 to 7, the sorption of U(VI) on Si was reduced in the presence of HA in comparison to the system without HA. In subsequent experiments the concentration of HA will be increased to 50 ppm. (authors)

12 MANAGEMENT OF RADIOACTIVE AND NON-RADIOACTIVE W↗

Installing Deep Groundwater Monitoring Wells in a Volcanic Dominated Rift Basin: Los Alamos National Laboratory, New Mexico - 17594

Los Alamos National Laboratory (LANL, or the Laboratory) is located in northern New Mexico near the west margin of the Espanola Basin. LANL is underlain by a complex basin-fill sequence of alluvial fan deposits, volcanic tuff, basaltic and dacitic lavas, and riverine deposits. On-going environmental remediation and characterization activities have evolved to improve the performance of groundwater monitoring wells, ensuring they yield representative groundwater and core samples. Groundwater occurs as canyon-fill alluvial water, perched intermediate-depth water associated with the basalts and other local-scale perching horizons, and as a regional-scale aquifer that is the main water supply for the area. Anthropogenic contaminants are found in all three groundwater zones. The regional aquifer below LANL is nominally 1000-1400 feet below ground surface (bgs). Monitoring wells at the Laboratory, are therefore, among the deepest routinely installed in the US. Logistical challenges at LANL include steep terrain, widespread cultural sites, and threatened and endangered species habitat restrictions. Additionally, the cost of installing monitoring wells is high because of groundwater depths and the variable drilling techniques that are required to characterize and install wells in a complex geologic environment. A major challenge to the characterization approach at LANL has been to meet sample quality requirements while minimizing drilling costs. In the late 1990's threaded drill-casing was advanced by rotary drilling methods using compressed air as the only circulation fluid. This resulted in relatively low impacts to the geochemical integrity of rock and groundwater samples, but led to frequent episodes of stuck casing. Additional fluids were introduced to the air-rotary program, improving penetration rates, but also resulting in non-representative groundwater samples due to long-term impacts to the aquifer in the vicinity of the well screen. Mud-rotary drilling was incorporated into the program, but it also had significant long-term impacts on groundwater quality, and often inhibited identification of perched groundwater zones and accurate identification of the water table in the regional aquifer. Current drilling practice makes limited use of fluid additives (e.g. foam) to supplement air circulation methods in order to advance drill casing through the vadose zone. Starting about 100 feet above the water table, drill casing is advanced to the target horizon in the regional aquifer using only air and municipal water (when needed) for circulation. Additionally, the threaded drill casing couplings have been replaced with welded connections, significantly reducing the occurrence of stuck casing. Careful observations of water production and water levels during drilling, coupled with the ability to retract casing for video and geophysical logs, now allows for robust characterization of perched groundwater systems and accurate definition of the top of regional saturation. Recent advances in the drilling program include combined dual-rotary/sonic drilling to depths up to 1150 feet and dual-rotary casing advance at angles up to 25 deg. from vertical. The former allows for core collection with minimal fluid addition, thereby preserving pore water chemistry. The latter method allows for well installation into portions of the aquifer otherwise inaccessible due to constraints at the surface (e.g., cultural sites or topography). Similar to the development of drilling techniques, both well design and groundwater sampling system design have evolved throughout the program. Current well design emphasizes a minimal annulus of filter pack, maximum screen slot size based on formation sieve analyses, and thorough well development to mitigate formation damage due to drilling. To sample groundwater at multiple levels in the same well, earlier sampling systems included Westbay{sup R} multi-zone systems and dual-screen single-pump and dual-screen dual-pump systems designed in collaboration with Baski, Inc. These multi-zone sampling systems proved difficult to develop and maintain given the depth to groundwater, and most current well installations are configured with a single screen and a submersible pump. The ability to purge from a well-developed single-screen well has substantially improved the collection of representative groundwater samples. A carefully crafted groundwater characterization program in target aquifers at depths ranging from 1,000 to 1,400 feet bgs within a complex geologic setting, while also retaining the ability to collect representative core and groundwater samples, may have application at a number of sites throughout the environmental industry. Optimizing each well to meet program objectives while reducing total project costs benefits all environmental investigations. (authors)

12 MANAGEMENT OF RADIOACTIVE AND NON-RADIOACTIVE W↗