Engineering Papers⌕ Search

SEARCH · Engineering Papers

Results for “cooling system”

Search indexed NASA NTRS and DOE OSTI research on propulsion, heat transfer, battery materials and energy systems. Follow report and document links to the original sources.

Quote a phrase for an exact phrase match. Source license links do not imply unrestricted reuse.

At least 433 records · Page 24

Progress in the HTTF Benchmark and RELAP5-3D Gas-Cooled Reactor Validation

This slide set presents results of analysis done in the first year after the kickoff of the HTTF benchmark. This work includes the development of a new RELAP5-3D model of the facility and collection and presentation of results from one of the exercises in the benchmark. Highlights include good agreement between the new and legacy models for full-power steady state and similar predictions of maximum block temperature during a pressurized conduction cooldown. Additionally, code-to-code comparisons of a full-power steady state and depressurized conduction cooldown (DCC) from full-power steady state as part of Problem 2 Exercises 1A and 1B show good agreement on temperatures predicted in the core but considerable spread in central reflector temperatures. During the DCC, temperature behavior is similar across all models, but cooldown rates are dictated by the performance of the reactor cavity cooling system

22 GENERAL STUDIES OF NUCLEAR REACTORS↗

Hydrogen Internal Combustion Engine - Franco Ocampo

This intern poster is personal research on a Hydrogen Internal Combustion Engine. The poster oversees the core problems with the idea of a HICE. The main problem addressed is abnormal combustion which can be a safety hazard firstly, but also mitigate the performance of the engine severely. Solutions include direct fuel injection, alternative cooling systems, and closer attention to valve timing and calibration in relation to fuel delivery.

08 - HYDROGEN↗

Evaluation of cooling setpoint setback savings in commercial buildings using electricity and exterior temperature time series data

Commercial buildings account for a significant amount of total energy produced in the US, and the Heating Ventilation and Cooling (HVAC) systems are one of the most significant components of their overall consumption. In this study, we proposed a new data-driven approach to evaluate HVAC cooling systems in commercial buildings and identify savings opportunities. The focus is an investigation of the impact of thermostat setpoint setback but using only whole building, electricity data taken at 15-min intervals for the analysis. We conducted a comparative study of setpoint setback characteristics on 432 commercial buildings with 5 building usage types across the United States. To accomplish this, both piecewise and Random Forest regression algorithms were employed using electricity and exterior temperature datasets to identify operational characteristics and the effective setpoints in the building to determine the corresponding savings opportunities. Both occupied and unoccupied time periods were studied across cooling degree days (CDD), when air conditioning is typically operational. Here the results show that in commercial buildings, on average, cooling systems account for 9.5% of total consumption. When a one degree setback during the cooling season is applied, an average of approximately 1.1% of annual consumption is achieved; retail and office buildings demonstrate the highest potential for savings. Additionally, we identified that the number of cooling degree days and base to peak ratio (BPR) are the most important variables for predicting the magnitude of the consumption of cooling systems.

32 ENERGY CONSERVATION, CONSUMPTION, AND UTILIZATI↗

Resilient cooling through geothermal district energy system

Decarbonization and resilience to heat waves have recently become high priorities for building and district energy systems. Geothermal coupled district heating and cooling systems that operate a water loop near ground temperature gain increasing adoption to support decarbonization. In these systems, vapor-compression machines, distributed in the energy transfer stations, lift the temperature up or down to the needs of the particular building. In principle, these systems can provide low-power, free cooling from the geothermal bore field during heat waves when electricity is often scarce. However, the performance of such a resilience operation mode and its implication on the energy system configuration and the sizing of the bore field and HVAC equipment is not yet understood. Consequently, we are assessing their resilience, power use and design implications under a scenario of a heat wave on five working days during which chillers are switched off to reduce electrical consumption. Our analysis is based on high-fidelity, coupled dynamic models of district energy, building-side HVAC and actual control logic, with whole building energy simulation used to assess thermal conditions in a 2004 vintage multi-zone office building in Chicago, IL. The results show that relying only on waterside economizer cooling, the indoor thermal conditions can be maintained in a tolerable range for the majority of the building zones with half the electrical energy compared to standard chiller operation. Thermal comfort in the hottest zones can be further improved by oversizing the cooling coil. However, the waterside economizer has significant implications on the system configuration and sizing: The geothermal bore field needs to be sized about 30% larger than the upper limit of the range observed for conventional geothermal systems. Nevertheless, if a central chiller plant is added, the bore field can be downsized to the typical design range. The latter configuration still allows compressor-less cooling during the heat wave with peak power reduced by 60% compared to the standard design and chiller operation.

15 GEOTHERMAL ENERGY↗

A Novel Steam Condenser with Loop Thermosyphons and Film-Forming Agents for Improved Heat Transfer Efficiency and Durability

In this DOE/NETL BAA program, Advanced Cooling Technologies, Inc. (ACT), with Suez Water Technologies & Solutions (Suez), developed film-forming amine coatings applied to condenser surfaces that incorporated loop thermosyphons to enhance steam surface condenser performance and efficiency for coal-fired power plants. The condensation phenomenon resulting from these coatings promotes efficient dropwise condensation without additional thermal resistance through the use of film-forming amines (FFA). The loop thermosyphon technology was being developed to supplant current pumped cooling water systems to reduce operations and maintenance issues, reduce energy use, and promote high thermal performance. Both of ACT’s advanced coating and loop thermosyphon technologies were developed for application to wet cooling and indirect dry cooling systems. Internal steam condensation and subsequent heat dissipation complete the thermodynamic power cycle used by power plant cooling systems. The successful 3-year project period delved into understanding the experimental performance gain using film-forming amines applied to flat and tubular condenser surfaces under realistic operating conditions. The performance gain was used to create a technoeconomic analysis to more clearly understand the market value for power plants using FFA coatings to achieve dropwise condensation on condenser surfaces. A tall (50 ft.) loop thermosyphon was designed, fabricated, and tested to optimize the performance characteristics by tuning the working fluid charge and determining the temperature drop across the loop at different heat loads. Commercialization opportunities were explored to transition the loop thermosyphon work into the building HVAC market.

20 FOSSIL-FUELED POWER PLANTS↗

System and method for enclosing piston cooling gallery

A system includes a piston assembly. The piston assembly includes a crown portion having a crown, an outer wall coupled to the crown, a first inner wall disposed inside of the outer wall, a first fluid chamber disposed radially between the outer wall and the first inner wall, and an angled wall insert. An opening extends into the first fluid chamber in an axially inward direction. The outer wall, the first inner wall, the first fluid chamber, the opening, and the angled wall insert extend circumferentially about a central axis of the piston assembly. The angled wall insert is disposed in the opening, and the first fluid chamber is disposed axially between the crown and the angled wall insert.

Zimmerman, Daniel David↗

Optimal environmental and economic performance trade-offs for fifth generation district heating and cooling network topologies with waste heat recovery

Network topology greatly influences both the economic and environmental performance of fifth generation district heating and cooling (5GDHC) systems. In this study the optimal trade-offs between the environmental and economic performance of 5GDHC network topologies for a five-building district with waste heat recovery were explored. A life cycle assessment method was used to calculate the total life cycle CO 2 emissions (LCCO2) associated with the installation and operation of various network topologies. Twelve months of empirical data from a data center cooling system were analyzed to assess its suitability for integration into a 5GDHC system. The most suitable method for utilizing this waste heat was selected based on the ambient loop warm pipe setpoint, waste heat temperature, and district energy system configuration. A multi-objective optimization algorithm was used to select the 5GDHC network topology that provided the optimal trade-off between LCCO2 and life cycle cost (LCC). A trade-off parameter was employed to weigh the importance of each objective in the selection process. The results showed waste heat from the data center was suitable for integration into the 5GDHC system due to its availability and consistent temperature profile. When return temperatures of 25 °C or higher were available from the liquid-cooled system, direct pre-heating of the ambient loop warm pipe was found to be the most effective waste heat integration method. The selection of the network topology that provided the optimal trade-off between LCCO2 and LCC (optimal trade-off topology) was highly dependent on factors such as fuel prices, CO 2 prices, electricity CO 2 emissions factors, availability of waste heat, embodied CO 2 emissions associated with network installation and network infrastructure costs. Optimal trade-off topologies produced substantial LCCO2 reductions relative to corresponding LCC increases. LCCO2 reduction to LCC increase ratios from 5.78 to 117.79 were identified with CO 2 offset costs ranging from 4.77 to 60.08 ($/tCO 2 e).

32 ENERGY CONSERVATION, CONSUMPTION, AND UTILIZATI↗

Closed-loop brayton cycle system with turbine blade cooling

A closed-loop Brayton cycle system utilizes supercritical carbon dioxide as the working fluid for the system to achieve higher efficiencies than can be achieved with traditional open-loop gas turbine engines. A bleed channel is used to direct a flow of cooling fluid to cool the turbine blades during operation of the system, preventing damage to the turbine blades during operation of the system. The bleed channel includes a bleed inlet fluidly coupled between a first recuperator and a second recuperator and a bleed outlet fluidly coupled to the turbine blades. The bleed channel is configured to direct the flow of cooling fluid to the turbine blades at a desired temperature and pressure.

Taylor, Stephen H.↗

CoolPINNs: A physics-informed neural network modeling of active cooling in vascular systems

Emerging technologies like hypersonic aircraft, space exploration vehicles, and batteries avail fluid circulation in embedded microvasculatures for efficient thermal regulation. Modeling is vital during the design and operational phases of these engineered systems. However, many challenges exist in developing a modeling framework. What is lacking is an accurate framework that (i) captures sharp jumps in the thermal flux across complex vasculature layouts, (ii) deals with oblique derivatives (involving tangential and normal components), (iii) handles nonlinearity because of radiative heat transfer, (iv) provides a high-speed forecast for real-time monitoring, and (v) facilitates robust inverse modeling. Here, this paper addresses these challenges by availing the power of physics-informed neural networks (PINNs). We develop a fast, reliable, and accurate Scientific Machine Learning (SciML) framework for vascular-based thermal regulation—called CoolPINNs: a PINNs-based modeling framework for active cooling. The proposed mesh-less framework elegantly overcomes all the mentioned challenges. The significance of the reported research is multi-fold. First, the framework is valuable for real-time monitoring of thermal regulatory systems because of rapid forecasting. Second, researchers can address complex thermoregulation designs since the approach is meshless. Finally, the framework facilitates systematic parameter identification and inverse modeling studies, perhaps the most significant utility of the current framework.

97 MATHEMATICS AND COMPUTING↗

Multiphysics analysis system for heat pipe cooled micro-reactors employing PRAGMA-OpenFOAM-ANLHTP

A multiphysics analysis system for neutronics/thermo-mechanical/heat-pipe analysis of heat pipe cooled micro-reactors was developed using the PRAGMA code as the neutronics engine. PRAGMA, which used to be a GPU-based continuous-energy MC code for power reactor applications, now has an extended geometry package to handle geometries with unstructured meshes generated by the ANSYS Design-Modeler and Meshing. The NVIDIA ray tracing engine OptiX was exploited for efficient neutron transport on unstructured geometry. On the multiphysics side, the open-source CFD tool OpenFOAM and one-dimensional heat pipe analysis code ANLHTP were adopted. The manager-worker system based on the MPI dynamic process management (DPM) model enables efficient coupling of codes employing different parallelization schemes. With all the features, the multiphysics analysis of the one-sixth symmetrical MegaPower 2D core was performed and it demonstrated the benefit of the tight integration of the three-way coupling system and one-to-one geometry coupling strategy. (authors)

21 SPECIFIC NUCLEAR REACTORS AND ASSOCIATED PLANTS↗

Evaluating direct vessel injection accident-event progression of AP1000 and key figures of merit to support the design and development of water-cooled small modular reactors

The passive safety systems (PSSs) within water-cooled reactors are meticulously engineered to function autonomously, requiring no external power source or manual intervention. They depend exclusively on inherent natural forces and the fundamental principles of reactor physics, such as gravity, natural convection, and phase changes, to manage, alleviate, and avert the release of radioactive materials into the environment during accident scenarios like a loss-of-coolant accident (LOCA). PSSs are already integrated into such operating commercial reactors as the Advanced Pressurized Reactor-1000 MWe (AP1000) and the Water-Water Energetic Reactor-1200 MWe (WWER-1200) are adopted in most of the upcoming small modular reactor (SMR) designs. Examples of water-cooled SMR PSSs are the passive emergency core-cooling system (ECCS), passive containment cooling system (PCCS), and passive decay-heat removal system, the designs of which vary based on reactor system-design requirements. However, understanding the accident-event progression and phases of a LOCA is pivotal for adopting a specific PSS for a new SMR design. This study covers the accident-event progression for direct vessel injection (DVI) small-break loss-of-coolant accident (SB-LOCA), associated physics phenomena, knowledge gaps, and important figures of merit (FOMs) that may need to be evaluated and assessed to validate thermal-hydraulics models with an available experimental dataset to support new SMR design and development.

21 SPECIFIC NUCLEAR REACTORS AND ASSOCIATED PLANTS↗

Power generation-cooling water Nexus: Impacts of cooling water shortage on power system operation - a simulation case study in Illinois, U.S

Cooling water shortage, frequently attributed to drought and heat waves, poses a significant threat to the operations of thermoelectric power plants and further poses a challenge for the entire power system and environmental stakeholders. Recognizing the critical nexus between power generation and cooling water availability and the potential ability of power generations to adjust generation schedules during cooling water shortages, this paper introduces a security-constrained unit commitment and economic dispatch model considering water-energy nexus. In specific, the model is augmented with a unit-level cooling water requirement (CWR) model and multi-level cooling water availability (CWA) constraints. The unit-level CWR model quantifies the cooling water withdrawal per MWh of power generation, taking into account factors such as thermoelectric generation technologies, cooling system technologies, and environmental parameters. The multi-level CWA constraints incorporate pump-level, plant-level, watershed-level, and forced minimum power constraints, utilizing data derived from actual-based cooling water shortage scenarios. Using a simulation case study in Illinois, United States, this research examines the reliability, economic, and environmental implications of cooling water shortages on power system operations. The results show that Illinois may experience 10-15% daily load curtailment and severe congestion between certain regions from the east to central during cooling water shortages, while once-through and wet-tower units experience a 52% and 17% reduction in power generation. In conclusion, overall cooling water withdrawal decreases by 24-38% as severity intensifies.

Cooling water shortage↗

Feasibility of Deep Direct-Use Geothermal on the West Virginia University Campus-Morgantown, WV

In 2010, research completed by the Southern Methodist University (SMU) Geothermal Laboratory estimated temperatures at reasonable drilling depths in the state of West Virginia (WV) were in the temperature range desirable for district heating. This higher temperature region extends from north-central WV (Monongalia County) to southeastern WV (Greenbrier County). The Morgantown campus of West Virginia University (WVU) is located within the north-central region, and as part of the 2016 study on Low-temperature Geothermal Play Fairway Analysis for the Appalachian Basin (GPFA-AB), Morgantown is identified as one of the priority locations for further analysis of the potential for deep direct-use (DDU) of geothermal energy. In this project, the feasibility of developing a Geothermal District Heating and Cooling (GDHC) system for the WVU campus in Morgantown, WV, to replace the current coal-fired steam heating and cooling system, is evaluated.

15 GEOTHERMAL ENERGY↗

Integrated-photonics-based systems for polarization-gradient cooling of trapped ions

Trapped ions are a promising modality for quantum systems, with demonstrated utility as the basis for quantum processors and optical clocks. However, traditional trapped-ion systems are implemented using complex free-space optical configurations, whose large size and susceptibility to vibrations and drift inhibit scaling to large numbers of qubits. In recent years, integrated-photonics-based systems have been demonstrated as an avenue to address the challenge of scaling trapped-ion systems while maintaining high fidelities. While these previous demonstrations have implemented both Doppler and resolved-sideband cooling of trapped ions, these cooling techniques are fundamentally limited in efficiency. In contrast, polarization-gradient cooling can enable faster and more power-efficient cooling and, therefore, improved computational efficiencies in trapped-ion systems. While free-space implementations of polarization-gradient cooling have demonstrated advantages over other cooling mechanisms, polarization-gradient cooling has never previously been implemented using integrated photonics. In this paper, we design and experimentally demonstrate key polarization-diverse integrated-photonics devices and utilize them to implement a variety of integrated-photonics-based polarization-gradient-cooling systems, culminating in the first experimental demonstration of polarization-gradient cooling of a trapped ion by an integrated-photonics-based system. By demonstrating polarization-gradient cooling using an integrated-photonics-based system and, in general, opening up the field of polarization-diverse integrated-photonics-based devices and systems for trapped ions, this work facilitates new capabilities for integrated-photonics-based trapped-ion platforms.

atom optics↗