Engineering Papers⌕ Search

SEARCH · Engineering Papers

Results for “controller”

Search indexed NASA NTRS and DOE OSTI research on propulsion, heat transfer, battery materials and energy systems. Follow report and document links to the original sources.

Quote a phrase for an exact phrase match. Source license links do not imply unrestricted reuse.

At least 433 records · Page 24

Controlling a power output of a nuclear reaction without control rods

A nuclear power system includes a reactor vessel that includes a reactor core mounted therein. The reactor core includes nuclear fuel assemblies configured to generate a nuclear fission reaction. The reaction vessel does not include any control rod assemblies therein. The nuclear power system further includes a riser positioned above the reactor core, a primary coolant flow path, a primary coolant that circulates through the primary coolant flow path to receive heat from the nuclear fission reaction and release the received heat to generate electric power in a power generation, and a control system communicably coupled to the power generation system and configured to control a power output of the nuclear fission reaction independent of any control rod assemblies.

Callaway, Allyson↗

Beyond PID Controllers: PPO with Neuralized PID Policy for Proton Beam Intensity Control in Mu2e

We introduce a novel Proximal Policy Optimization (PPO) algorithm aimed at addressing the challenge of maintaining a uniform proton beam intensity delivery in the Muon to Electron Conversion Experiment (Mu2e) at Fermi National Accelerator Laboratory (Fermilab). Our primary objective is to regulate the spill process to ensure a consistent intensity profile, with the ultimate goal of creating an automated controller capable of providing real-time feedback and calibration of the Spill Regulation System (SRS) parameters on a millisecond timescale. We treat the Mu2e accelerator system as a Markov Decision Process suitable for Reinforcement Learning (RL), utilizing PPO to reduce bias and enhance training stability. A key innovation in our approach is the integration of a neuralized Proportional-Integral-Derivative (PID) controller into the policy function, resulting in a significant improvement in the Spill Duty Factor (SDF) by 13.6%, surpassing the performance of the current PID controller baseline by an additional 1.6%. This paper presents the preliminary offline results based on a differentiable simulator of the Mu2e accelerator. It paves the groundwork for real-time implementations and applications, representing a crucial step towards automated proton beam intensity control for the Mu2e experiment.

43 PARTICLE ACCELERATORS↗

Prime Time for Model-Predictive Control? Assessing the Technical and Market Readiness of Advanced Controls in Buildings

Despite three decades of extensive research and field testing that have consistently validated the benefits of Model Predictive Control (MPC) in building applications, the technology has seen limited market adoption. This paper evaluates the readiness of MPC for widespread deployment, showcases recent demonstrations and field tests across diverse building types, including residential, small commercial, large commercial, and campus settings. Our results demonstrate that MPC can optimize system operations to achieve load shifting, minimize curtailment of on-site generation, and reduce energy costs by up to 80 %, while maintaining or improving occupant comfort. We also show that MPC can effectively control large assets, such as MW-sized thermal storage systems, and respond to dynamic pricing signals. However, achieving scale remains difficult due to labor-intensive workflows, reliance on a “PhD-in-the-loop” for MPC design and maintenance, susceptibility to fragile data infrastructure, and persistent workforce education and acceptance barriers. To bridge this gap, we outline a transition from bespoke, labor intensive prototypes toward streamlined, segment-targeted deployment strategies that leverage model templates, semantic tools, and generative AI. By automating control configuration and reducing engineering effort, these recommendations provide a pathway for transforming successful research demonstrations into scalable, market ready solutions for MPC-based controls.

Pritoni, Marco↗

Quality Control of High-Dose-Rate Brachytherapy: Treatment Delivery Analysis Using Statistical Process Control

Purpose: Statistical process control (SPC) is a quality control method used to ensure that a process is well controlled and operates with little variation. This study determined whether SPC was a viable technique for evaluating the proper operation of a high-dose-rate (HDR) brachytherapy treatment delivery system. Methods and Materials: A surrogate prostate patient was developed using Vyse ordnance gelatin. A total of 10 metal oxide semiconductor field-effect transistors (MOSFETs) were placed from prostate base to apex. Computed tomography guidance was used to accurately position the first detector in each train at the base. The plan consisted of 12 needles with 129 dwell positions delivering a prescribed peripheral dose of 200 cGy. Sixteen accurate treatment trials were delivered as planned. Subsequently, a number of treatments were delivered with errors introduced, including wrong patient, wrong source calibration, wrong connection sequence, single needle displaced inferiorly 5 mm, and entire implant displaced 2 mm and 4 mm inferiorly. Two process behavior charts (PBC), an individual and a moving range chart, were developed for each dosimeter location. Results: There were 4 false positives resulting from 160 measurements from 16 accurately delivered treatments. For the inaccurately delivered treatments, the PBC indicated that measurements made at the periphery and apex (regions of high-dose gradient) were much more sensitive to treatment delivery errors. All errors introduced were correctly identified by either the individual or the moving range PBC in the apex region. Measurements at the urethra and base were less sensitive to errors. Conclusions: SPC is a viable method for assessing the quality of HDR treatment delivery. Further development is necessary to determine the most effective dose sampling, to ensure reproducible evaluation of treatment delivery accuracy.

62 RADIOLOGY AND NUCLEAR MEDICINE↗

Standard Library Plant Controller Model Specification for a Grid-Forming Hybrid Control Inverter-Based Resource (REPCGFM_C1)

This document describes a standard library plant controller model to interface with the grid-forming hybrid control inverter-based resource (IBR) model. The initial version of model specification was jointly developed by Pacific Northwest National Laboratory (PNNL), Tesla Energy, and EPRI, and it was revised multiple times later to incorporate suggestions from WECC MVS members. Tesla Energy provided main control algorithms to support the development of this model specification. This standard library model is developed to help the utility industry better understand the GFM technology. The model could be used to represent equipment for long-term planning studies where vendor-specific models are not available. As equipment matures and improves, standard library models will be updated to capture the new functionalities of GFMs. It is not intended that these models will always remain representative of all future GFM technologies.

24 POWER TRANSMISSION AND DISTRIBUTION↗

From occupants to occupants: A review of the occupant information understanding for building HVAC occupant-centric control

Occupants are the core of the built environment. Traditional Heating, Ventilation, and Air-Conditioning (HVAC) systems operate with predefined schedules and maximum occupancy assumptions with no consideration of specific occupant information. These generalized assumptions usually do not align with the actual demand and result in over-conditioning and occupant discomfort. In recent years, with the aid of Information & Communication Technology (ICT) and Computer Science (CS), it is possible to acquire real-time and accurate occupant information to satisfy the exact thermal requirement through specific HVAC control in one particular built environment. This mechanism is called HVAC “Occupant-centric Control (OCC).” HVAC OCC strategy starts with collecting the occupant’s information (e.g., presence/absence) and then applies it to meet the occupant’s requirement (e.g., thermal comfort). However, even though some research studies and field pilot demonstrations have been devoted to the field of OCC, there is a lack of systematic knowledge about occupant data, which is the principal component of OCC for HVAC researchers and practitioners. To fill this gap, this review paper discusses OCC with a particular emphasis on occupant information and investigates how this information can assist HVAC operation in providing an acceptable built environment in required spaces during the required time. Finally, we provide a fine-grained, comprehensive picture of occupant information, discuss its features, the modalities of information feed-in into the HVAC control, and the application of commonly utilized occupant information for OCC.

32 ENERGY CONSERVATION, CONSUMPTION, AND UTILIZATI↗

Detecting control system misbehavior by fingerprinting programmable logic controller functionality

In recent years, attacks such as the Stuxnet malware have demonstrated that cyberattacks against control systems cause extensive damage. These attacks can result in physical damage to the networked systems under their control. In this paper, we discuss our approach for detecting such attacks by distinguishing between programs running on a programmable logic controller (PLC) without having to monitor communications. Using power signatures generated by an attached, high-frequency power measurement device, we can identify what a PLC is doing and when an attack may have altered what the PLC should be doing. To accomplish this, we generated labeled data for testing our methods and applied feature engineering techniques and machine learning models. The results of this research demonstrate that Random Forests and Convolutional Neural Networks classify programs with up to 98% accuracy for major program differences and 84% accuracy for minor differences. Our results can be used for both online and offline applications.

97 MATHEMATICS AND COMPUTING↗

Surface-Engineered MXenes: Electric Field Control of Magnetism and Enhanced Magnetic Anisotropy

Controlling magnetism in two-dimensional (2D) materials via electric fields and doping enables robust long-range order by providing an external mechanism to modulate magnetic exchange interactions and anisotropy. Here in this report, we predict that transition metal carbide and nitride MXenes are promising candidates for controllable magnetic 2D materials. The surface terminations introduced during synthesis act as chemical dopants that influence the electronic structure, enabling controllable magnetic order. We show ground-state magnetic ordering in Janus M 2 XO x F 2–x (M is an early transition metal, X is carbon or nitrogen, and x = 0.5, 1, or 1.5) with asymmetric surface functionalization, where local structural and chemical disorder induces magnetic ordering in some systems that are nonmagnetic or weakly magnetic in their pristine form. The resulting magnetic states of these noncentrosymmetric structures can be robustly switched and stabilized by tuning the interlayer exchange couplings with small applied electric fields. Furthermore, bond directionality is enhanced by Janus functionalization, resulting in improved magnetic anisotropy, which is essential to stable 2D magnetic ordering. The mixed termination-induced anisotropy leads to robust Ising ferromagnetism with an out-of-plane easy axis over the full range of relevant termination compositions for Janus Mn 2 N. Janus Cr 2 C, V 2 C, and Ti 2 C were found to be robustly antiferromagnetic. Our results provide a strategy for exploiting asymmetric surface functionalization to achieve room-temperature nanoscale magnetism under ambient conditions in MXenes with currently available synthesis techniques.

2D materials↗

Syntheses of terminal control for nonlinear stationary controlled system under incomplete information

By constructing a Luenberger-type asymptotic observer, a method of finding the control function, that ensures the translation of a class of nonlinear stationary control systems of ordinary differential equations from the initial state to a given final state taking into account the actual measured values, was developed. A constructive criterion guaranteeing the existence of solution of this problem was found. An algorithm is proposed for constructing a control function that transfer wide class of nonlinear systems of ordinary differential equations from an initial state to an fixed state. The algorithm is convenient for numerical implementation. A constructive condition is obtained for which this transfer is possible.

71 CLASSICAL AND QUANTUM MECHANICS, GENERAL PHYSIC↗

Exact null controllability of degenerate evolution equations with scalar control

Necessary and sufficient conditions for the exact null controllability of a degenerate linear evolution equation with scalar control are obtained. These general results are used to examine the exact null controllability of the Dzektser equation in the theory of seepage. Bibliography: 13 titles.

97 MATHEMATICS AND COMPUTING↗

A Multifidelity Ensemble Kalman Filter with Reduced Order Control Variates

This work develops a new multi delity ensemble Kalman lter (MFEnKF) algorithm based on linear control variate framework. The approach allows for rigorous multi delity extensions of the EnKF, where the uncertainty in coarser delities in the hierarchy of models represent control variates for the uncertainty in ner delities. Small ensembles of high delity model runs are com- plemented by larger ensembles of cheaper, lower delity runs, to obtain much improved analyses at only small additional computational costs. We investigate the use of reduced order models as coarse delity control variates in the MFEnKF, and provide analyses to quantify the improvements over the traditional ensemble Kalman lters. We apply these ideas to perform data assimilation with a quasi-geostrophic test problem, using direct numerical simulation and a corresponding POD-Galerkin reduced order model. Numerical results show that the two- delity MFEnKF provides better analyses than existing EnKF algorithms at comparable or reduced computational costs.

97 MATHEMATICS AND COMPUTING↗