Engineering Papers⌕ Search

SEARCH · Engineering Papers

Results for “controllable loads”

Search indexed NASA NTRS and DOE OSTI research on propulsion, heat transfer, battery materials and energy systems. Follow report and document links to the original sources.

Quote a phrase for an exact phrase match. Source license links do not imply unrestricted reuse.

At least 433 records · Page 24

Activating nano-bulk interplays for sustainable ammonia electrosynthesis

Small changes in a catalyst’s composition, modification, and/or integration into a reactor can have significant yet often poorly understood effects on (electro)catalysis. Here we demonstrate the careful tailoring of Ru/La 0.25 Ce 0.75 O 2-x catalysts through the post-synthesized hydrothermal treatment together with control over the Ru loadings to create hydroxyl groups and electronic restructuring for ammonia electrosynthesis. When integrated into a protonic ceramic electrolyzer, the in situ formed Ce 3+ -OH/Ru sites facilitate both the N≡N decoupling and N—H formation at 400 °C and 1 bar of N 2 , boosting the ammonia production rate (2.92 mol h -1 m -2 ) up to 100-fold higher than the current state-of-the-art electrolyzers. Moreover, such catalysts and electrolyzer design concepts can be readily tuned to more complex applications such as coproducing ammonia and other chemicals with hydrocarbons as direct hydrogen sources. Here, the creation of coordinated saturated support –OH/metal sites in the advanced electrolyzer offers an attractive approach for future clean-energy and green-chemical industries.

03 NATURAL GAS↗

Community structure and function during periods of high performance and system upset in a full-scale mixed microalgal wastewater resource recovery facility

Microalgae have the potential to exceed current nutrient recovery limits from wastewater, enabling water resource recovery facilities (WRRFs) to achieve increasingly stringent effluent permits. The use of photobioreactors (PBRs) and the separation of hydraulic retention and solids residence time (HRT/SRT) further enables increased biomass in a reduced physical footprint while allowing operational parameters (e.g., SRT) to select for desired functional communities. However, as algal technology transitions to full-scale, there is a need to understand the effect of operational and environmental parameters on complex microbial dynamics among mixotrophic microalgae, bacterial groups, and pests (i.e., grazers and pathogens) and to implement robust process controls for stable long-term performance. Here, we examine a full-scale, intensive WRRF utilizing mixed microalgae for tertiary treatment in the US (EcoRecover, Clearas Water Recovery Inc.) during a nine-month monitoring campaign. We investigated the temporal variations in microbial community structure (18S and 16S rRNA genes), which revealed that stable system performance of the EcoRecover system was marked by a low-diversity microalgal community (D INVSIMPSON = 2.01) dominated by Scenedesmus sp. (MRA = 55 %-80 %) that achieved strict nutrient removal (effluent TP < 0.04 mg·L -1 ) and steady biomass concentration (TSS monthly avg . = 400–700 mg·L −1 ). Operational variables including pH, alkalinity, and influent ammonium (NH 4 + ), correlated positively (p < 0.05, method = Spearman) with algal community during stable performance. Further, the use of these parameters as operational controls along with N/P loading and SRT allowed for system recovery following upset events. Importantly, the presence or absence of bacterial nitrification did not directly impact algal system performance and overall nutrient recovery, but partial nitrification (potentially resulting from NO 2 − accumulation) inhibited algal growth and should be considered during long-term operation. The microalgal communities were also adversely affected by zooplankton grazers (ciliates, rotifers) and fungal parasites (Aphelidium), particularly during periods of upset when algal cultures were experiencing culture turnover or stress conditions (e.g., nitrogen limitation, elevated temperature). Altogether, the active management of system operation in order to maintain healthy algal cultures and high biomass productivity can result in significant periods (>4 months) of stable system performance that achieve robust nutrient recovery, even in winter months in northern latitudes (WI, USA).

32 ENERGY CONSERVATION, CONSUMPTION, AND UTILIZATI↗

A synthetic building operation dataset

Abstract This paper presents a synthetic building operation dataset which includes HVAC, lighting, miscellaneous electric loads (MELs) system operating conditions, occupant counts, environmental parameters, end-use and whole-building energy consumptions at 10-minute intervals. The data is created with 1395 annual simulations using the U.S. DOE detailed medium-sized reference office building, and 30 years’ historical weather data in three typical climates including Miami, San Francisco, and Chicago. Three energy efficiency levels of the building and systems are considered. Assumptions regarding occupant movements, occupants’ diverse temperature preferences, lighting, and MELs are adopted to reflect realistic building operations. A semantic building metadata schema - BRICK, is used to store the building metadata. The dataset is saved in a 1.2 TB of compressed HDF5 file. This dataset can be used in various applications, including building energy and load shape benchmarking, energy model calibration, evaluation of occupant and weather variability and their influences on building performance, algorithm development and testing for thermal and energy load prediction, model predictive control, policy development for reinforcement learning based building controls.

24 POWER TRANSMISSION AND DISTRIBUTION↗

Advanced co-simulation framework for assessing the interplay between occupant behaviors and demand flexibility in commercial buildings

With buildings contributing significantly to electricity usage, enabling demand flexibility becomes a challenge, especially when accounting for occupant comfort. This study introduces an innovative co-simulation framework integrating multiple models: heating, ventilation, and air conditioning (HVAC) system, building zone load, indoor airflow, supervisory control, and occupant comfort and behavior. Uniquely, this framework allows for a comprehensive and dynamic analysis of building systems and occupant interactions in demand response events. Using this framework, we conducted a case study using a typical small office building model. Specifically, we focused on three areas: (1) the impact of indoor airflow modeling on energy use, occupant comfort, and behaviors forecasting, (2) the impact of occupant behaviors on demand flexibility, and (3) occupant comfort and behaviors under demand response events. Key performance indicators such as energy use, flexibility factor, durations of occupant discomfort and occupant behaviors were analyzed. Our findings indicated variations in energy usage and occupant comfort within demand flexibility events, marked by uncertainty boundaries, with variability in demand shedding up to 57.9%. Here, we concluded that this framework is suitable for analyzing typical commercial buildings and their HVAC systems in terms of demand flexibility potential under the impact of occupant behaviors.

32 ENERGY CONSERVATION, CONSUMPTION, AND UTILIZATI↗

The Inner Shell Spectroscopy beamline at NSLS-II: a facility for in situ and operando X-ray absorption spectroscopy for materials research

The Inner Shell Spectroscopy (ISS) beamline on the 8-ID station at the National Synchrotron Light Source II (NSLS-II), Upton, NY, USA, is a high-throughput X-ray absorption spectroscopy beamline designed for in situ, operando, and time-resolved material characterization using high monochromatic flux and scanning speed. This contribution discusses the technical specifications of the beamline in terms of optics, heat load management, monochromator motion control, and data acquisition and processing. Results of the beamline tests demonstrating the quality of the data obtainable on the instrument, possible energy scanning speeds, as well as long-term beamline stability are shown. The ability to directly control the monochromator trajectory to define the acquisition time for each spectral region is highlighted. Examples of studies performed on the beamline are presented. The paper is concluded with a brief outlook for future developments.

36 MATERIALS SCIENCE↗

A 1kV, 480V Power Electronics Hub for DER Integration in Commercial Buildings

Power electronic (PE) systems are increasingly being integrated into distribution and sub-distribution networks in support of distributed energy resource integration (DERs), electric vehicle (EV) charging (particularly in the case of fast charging infrastructure), and improvement in power quality for high performance computing and/or servers farms. This provides an opportunity to research and develop integrated PE systems that can function as single systems thereby bringing additional functionality and benefits to the overall system. The goal of this paper is to demonstrate foundational technologies and capabilities for a multiport power electronics energy hub that can intelligently coordinate and control integrated sources and loads. The focus for this digest is on a commercial building use case which is demonstrated in hardware.

Starke, Michael↗

A Cost-Effective Wave Energy Harvesting System with Maximum Power Point Tracking Capability

In this paper, we propose a low-cost bidirectional four-switch inverter that transfers three-phase energy between a permanent magnet synchronous generator (PMSG) driven by a wave energy collector and the power grid or a local ac load. To achieve high control performance, the machine-side inverter uses a high-gain observer for rotor position estimation and a Lyapunov-based approach for torque control. For the gridside inverter control, we estimate the filter capacitor voltage with a model reference adaptive system and control the dc-link voltage with a Lyapunov-based energy function. We also track the maximum power point from the sea waves with an integral control law that actively matches the generator impedance with that of the wave collection device. The proposed system supports both grid-following/forming modes. We validate our control design with simulation results on a 3-kW hardware setup.

wave energy, power systems integration, control de↗

Development of High Temperature (>700°C) molten Salt Pump Technology for Gen3 Solar Power Tower Systems

Generation 3 Concentrating Solar Power (CSP) Systems require thermal energy storage that can efficiently receive solar heat and deliver it to a working fluid at temperatures greater than 700°C. For liquid systems, the thermal transfer fluid must be phase stable over large temperature ranges. High temperature molten salts meet this criteria, but are difficult liquids to handle. The high heat and salt content can be very corrosive to several different materials that are wetted by the liquid salt. For power tower collectors, the molten salt must be pumped under high pressure to the top of the collector tower. These pumps have impellers and shafts as part of their rotating elements, and under load, require bearings to control shaft movement while rotating. These high temperature pumps require submerged bearings, and thus bearing materials that can withstand the temperature and molten salt contact over long periods of time. This is essential for keeping pump maintenance costs low, and downtime to a minimum. Long running bearing materials is an enabling technology for integrated liquid systems in Generation 3 CSP Systems. Keeping costs low and systems reliable are critical for the broad adoption of Gen 3 CSP Systems. Hayward Tyler, Inc (HTI) proposed development of journal bearing materials for use in vertical pumps designed for pumping high temperature molten salt on both the hot and cold sides of the solar power tower. To complete this objective, HTI utilized the testing capabilities of Oak Ridge National Laboratory (ORNL) and High Temperature System Design (HTSD). Materials would first be selected for static corrosion testing, then downselected for tribological testing. Successful tribologically tested materials would then be downselected for use in additional test regimes. Ten samples were selected for static corrosion testing. Three passed the static testing regime. Two of these materials were downselected for ball material in tribological testing against three metallic alloys: Sintered Y2O3 Partially Stabilized Zirconia YTZP and Silicon Nitride, Grade 147-31N. HTI also proposed collecting data from a thorough bearing test regime using a test rig designed and built as part of this project, and also a conceptual design for a high temperature molten salt vertical pump. HTI withdrew from the project prior to completion of this work and this report reflects only the work completed prior to withdrawal. The completed work produced two papers, one manuscript submitted for publication, and one paper published in the journal Solar Energy Materials and Solar Cells. The papers are: “Tribological behavior of ceramic-alloy bearing contacts in molten salt lubrication for concentrating solar power” and “Material Selection and Corrosion Studies Of Candidate Bearing Materials For Use In Molten Chloride Salt."

14 SOLAR ENERGY↗

VERA Enhancements for Cross Section Shielding and Geometry Capabilities

Two tasks were undertaken in FY22 that focus on VERA enhancements. The first task involved improvements to the new cross section shielding capability that was added to VERA in FY21. This cell-based capability solves the slowing down problem for each pin cell using Dancoff factors calculated from the whole-core problem. The Dancoff factors are determined for each subgroup level for important sets of materials such as fuel rods, control rods, fuel rods loaded with gad, etc. The cross-section shielding is then performed for each cell using a 1D cylindrical collision probabilities (CP) calculation to obtain the equivalence cross sections required for the core transport calculations. The advantage of this method over the whole-core subgroup calculations is efficiency, since far fewer sweeps of the entire core are required.

22 GENERAL STUDIES OF NUCLEAR REACTORS↗

Aeroelastic Modelling of Large Wind Turbines: Towards a Unified OpenFAST-SEAHOWL Approach

In recent years, the scale of wind turbines has significantly increased to maximize energy capture for a given site (particularly offshore), presenting new challenges in terms of structural design and dynamics. As towers grow taller and blades grow longer, flexion and torsion of the latter have a non-negligible impact on the behavior and performance of the turbine in terms of overall loads, power production, and control. When representing large-scale wind turbines numerically to capture these important effects, particular attention must therefore be given to the level of fidelity for representing each structural component, as well as the coupling scheme used between them to keep simulations accurate, stable, and efficient. To address this issue, we combine here the two following tools: (1) OpenFAST, the reference whole-turbine simulation tool from NREL with standalone modules covering each physics and the choice between loose coupling and a new tight coupling scheme for structural dynamics, and (2) SEAHOWL, the whole-turbine simulation tool from TotalEnergies with monolithic coupling of structural dynamics through Project Chrono and partitioned coupling for multiphysics interactions.

17 WIND ENERGY↗

Grid-Enhanced, Mobility-Integrated Network Infrastructures for Extreme Fast Charging (GEMINI-XFC)

GEMINI-XFC will use first-of-a-kind integrated high-fidelity grid and transport modeling to identify effective pathways for widespread electrification, to design and evaluate integrated vehicle-grid control schemes, and to optimize electric vehicle integration at a full regional scale with individual customer resolution. Control variables will include: Charging station design and planning (where and what kind of charging stations); EV route scheduling considering grid "status"; and Dispatch of behind-the-meter energy storage and legacy voltage control actuators (on-load tap changes, voltage regulators, capacitors).

DIRECT ENERGY CONVERSION,POWER TRANSMISSION AND DI↗

High Power Density, Carbon Neutral Electrical Power Generation for Air Vehicles

The synergistic integration of a Solid Oxide Fuel Cell-Combustor (SOFC-C) with a turbogenerator (TG) will provide a very high fuel-to-electricity conversion efficiency while maintaining high power-to-weight ratio during high-altitude flight. The proposed SOFC-C-TG power generation technology exceeds the REEACH technical performance targets (TPT). This unique concept addresses many of the challenges faced in all electric propulsion-based aviation. The system has high part-load efficiency (more than 65% lower heating value (LHV)) during long cruise times, load following capability, high-power capacity at high altitudes adapting to low temperatures and pressures, rapid startup time of less than 30 minutes (proven with current SOFC technology), high power density (more than 3.2 kW/kg), efficient thermal management, and a foundation for a compact, efficient electrical storage and power generation system (ESPG). The SOFC-C concept achieves the technology targets by reducing the complexity of traditional fuel cell-gas turbine hybrid systems (FC-GT). The SOFC-C does not require heat exchangers and dramatically reduces the balance of plant increasing power density and performance in efficiency. The reduction in mass through elimination of heat exchangers, external reformer, and other components dramatically decreases the overall thermal dampening of the system which enables rapid startup and load following capability. Direct control of the cathode inlet temperature of the SOFC-C enables rapid warm-up of the SOFC tubes with the ability to reach operating temperature and full power in less than 30 minutes.

03 NATURAL GAS↗

A bi-level advanced control framework for large-scale control of buildings with system-level impact

Increased electricity consumption combined with new forms of generation is testing the reliability of our grid infrastructure. This work describes a method to improve the reliability of the grid through large-scale advanced building control. This paper develops a bi-level distributed control framework to shift the load of 153 buildings to achieve a system-level objective of tracking a power reference signal. This bi-level control is based on the previously-developed ANPV-MPC, a predictive controller that uses a Bayesian neural network to generate an accurate control model and adapt to changing conditions over time. By shifting the building electricity demand to better match the available power, the grid system supplying the buildings is more reliable as evidenced by the analysis of node voltages across an IEEE 13-bus distribution system. The proposed bi-level control framework tracks the system-level power reference with enough accuracy to regulate node voltages across the IEEE 13-bus distribution system within ANSI limits of ±5%. Additionally, the adaptive nature of ANPV-MPC allows each building across the system to adapt to changing conditions, further amplifying the system-level reliability.

32 ENERGY CONSERVATION, CONSUMPTION, AND UTILIZATI↗

Rethinking PCMI Failures Under Transient Conditions

Under PCMI conditions, the cladding strain is driven by either pellet swelling during normal operation or pellet thermal expansion in transients. The loading in PCMI is displacement controlled because friction between the pellet and the cladding results in a strain compatibility at the pellet/cladding interface. Failure is known to occur under PCMI loading conditions during operation when normal power changes result in release of iodine (and other fission products) causing stress corrosion cracking where the crack-propagation rate is dependent upon the cladding stress but slow relative to strictly mechanical failures. Failures after normal power changes are often referred to as failure by pellet-cladding interaction or PCI to distinguish it from PCMI. Such failures are considered displacement-controlled failures, as noted above, and occur with limited plastic strain. This is different to what is typically thought of as PCMI failure under transient conditions, either Anticipated Operational Occurrences (AOOs) or Reactivity Insertion Accidents (RIAs), which is generally assumed to occur once the cladding reaches a mechanical strain limit. But there are two features in the typical PCMI failure in an RIA that are not consistent with the PCMI assumptions. The first is the ductile shear failure feature in cross section and the second is a large crack opening post failure (e.g., see OI-11 failure in NSRR program). The ductile feature is indicative of a plastic instability that requires very large local strains, and the large crack opening must be the result of a release of energy, both of which are not expected if stress in the cladding was only driven by thermal expansion in the pellet. It is concluded that there must be a mechanism (likely related to rod internal pressure) that eliminates strain compatibility between the pellet and cladding – allowing strain localization to occur in what are known as PCMI transient failures. In some sense, these PCMI failures may actually be early burst failures that occur when thermal expansion causes uniform strains greater than a defined limit and fission gas pressure eliminate the strain compatibility

Cantonwine, Paul↗

A Machine Learning-Assisted Framework to Control Thermally Anisotropic Building Envelopes in Residential Buildings

To curb the energy consumption of buildings and their related CO2 emissions, Oak Ridge National Laboratory (ORNL) has developed the thermally anisotropic building envelope (TABE) —a multi-layer design comprising insulation materials and metal foils connected to thermal loops. In this study, a machine learning-assisted framework was developed to control the TABE in residential buildings to reduce the computation load for future optimal rule-based control and application. First, a 2D finite element model was established in COMSOL to calculate the hourly heat flux through exterior walls installed with the TABE. Then, TABE wall heat fluxes were simulated for various given indoor and outdoor boundary conditions, as well as thermal loops fluid temperatures and flow rates. Since the finite element simulations are computationally expensive, an artificial neural network (ANN) was then trained to use as a proxy of the finite element (COMSOL) modeling. Finally, the trained ANN model was coupled with the EnergyPlus model to predict the energy consumption of a US Department of Energy prototype single-family house installed with the TABE. An optimal simple rule-based control was determined from predefined rules for a case study. The results demonstrate that the developed machine learning–assisted framework can reduce 99.9% of the computation time while efficiently managing residential building energy for installed TABE walls.

Shen, Zhenglai↗

Peak load reduction and load shaping in HVAC and refrigeration systems in commercial buildings by using a novel lightweight dynamic priority-based control strategy

Reducing peak power demand in a building can reduce electricity expenses for the building owner and contribute to the efficiency and reliability of the electrical power grid. For the building owner, reduced expenses come from the reduction or elimination of peak power charges on electricity bills. For the power system operator, reducing peak power demand leads to a more predictable load profile and reduces stress on the electric grid system. Herein we present a computationally inexpensive, dynamic, and retrofit-deployable control strategy to effect peak load reduction and load shaping. The effectiveness of the control strategy is examined in a simulation with 80 air-conditioning units and 40 refrigeration units. The results show that a peak demand reduction of 60 kW can be achieved relative to peak demand in a typical set point–based approach. The proposed strategy was deployed in a gymnasium building with four rooftop HVAC units, where it showed over 15% peak demand (kW) reduction savings while maintaining or lowering energy consumption (in kilowatt-hours) relative to the set point–based thermostat controls.

24 POWER TRANSMISSION AND DISTRIBUTION↗

Validation of new and existing methods for time-domain simulations of turbulence and loads

We seek to obtain a second-by-second match between the simulated and measured structural loads of a utility-scale wind turbine. To obtain the one-to-one load simulations, we start with the furthest upstream component of the modeling chain: the turbulent inflow. We consider new and existing methods to generate constrained-turbulence flow fields. The new method is based on large-eddy simulations (LES) and machine learning (ML). The existing methods include Kaimal-based TurbSim and the superstatistical wind field model. The inflow measurements used to constrain these simulations are obtained with a nacelle-mounted scanning lidar. We compare the flow fields for the different inflow simulation approaches and validate their associated load predictions against measurements collected in the Rotor Aero-dynamics, Aeroelastics, and Wake (RAAW) field campaign. We find that the rotor-position control developed for this study is key in enabling the time match between measurements and simulations. When this control approach is used, the load simulation performance tracks with the inflow simulation fidelity, with LES+ML yielding errors ≤ 4% for the damage-equivalent loads of flapwise bending moment, and tower fore-aft bending moments.

17 WIND ENERGY↗

TRIPOLI-4 neutronics calculations for IAEA-CRP benchmark of CEFR start-up tests using new libraries JEFF-3.3 and ENDF/B-VIII

Sodium-cooled Fast Reactors (SFR) are one of the promising Generation IV fast reactors. The China Experimental Fast Reactor (CEFR) is a 65 MWth pool-type SFR with a high neutron leakage core using high enriched uranium oxide fuel. The CEFR start-up tests in 2010 consist of series of neutronics experiments. Essential experimental data are available from the 2018 IAEA-CEFR-CRP benchmark document and useful for the validation of neutron transport codes and nuclear data libraries. The TRIPOLI-4 Monte Carlo transport code is a general-purpose neutronics code using continuous-energy nuclear data libraries. It has a rich validation database covering different computational and experimental benchmark data sets to assure the accuracy and credibility of numerical studies. Previous TRIPOLI-4 SFR core physics calculations used mainly MOX fuels. SFR control rod worth studies with TRIPOLI-4 were mainly on big-size cores. To test the modeling capability of TRIPOLI-4 on fuel loading patterns and on variable control rods positions for SFRs and to check recent nuclear data libraries, it is interesting to investigate the CEFR start-up tests in this work, including core states from subcritical to supercritical, control rods and rod group worth, point kinetics parameters, and radial foil activation measurements. TRIPOLI-4 calculation results using new data libraries JEFF-3.3, ENDF/B-VIII, and those of ENDF/B-VII.1 for different CEFR core states are reported here. By means of different options of TRIPOLI-4, control-rod SAs reactivity worth, point kinetics parameters, and radial {sup 237}Np(n,f) fission rate distribution were successfully evaluated. Both ENDF/B-VIII and JEFF-3.3 nuclear data libraries provided reliable results with a difference of 170 +/- 11 pcm in k{sub eff}.

21 SPECIFIC NUCLEAR REACTORS AND ASSOCIATED PLANTS↗