Engineering Papers⌕ Search

SEARCH · Engineering Papers

Results for “conservative loads”

Search indexed NASA NTRS and DOE OSTI research on propulsion, heat transfer, battery materials and energy systems. Follow report and document links to the original sources.

Quote a phrase for an exact phrase match. Source license links do not imply unrestricted reuse.

At least 433 records · Page 24

The Thermal Response of TATB-Based PBXs

In the design mode of operation, TATB-­based PBXs, such as PBX 9502 or LX-­17, are promptly initiated by a detonator and booster system. In abnormal situations, such as accidents, a wide variety of non-­design-­mode insults can arise and it is desirable that these do not produce detonation but rather that, at most, they lead to a low chemical energy release. The most significant abnormal hazard is the direct shock initiation threat arising from high-­velocity fragment impact. This is quite well defined and may result in a detonative response if the fragment is large enough and fast enough. However, it is of considerably greater significance to the safety envelope of these explosives whether they are at all capable of DDT (deflagration-­to-­detonation transition), either at ambient or elevated temperatures since accidental insults to the explosive, either mechanical or thermal, that may produce local burning are both more numerous and more likely than shock loading. The purpose of this document is to demonstrate, based on the accumulated body of conservative experimental testing, that in explosive geometries and masses relevant to the Weapons Program, TATB-­based PBXs do not present a deflagration-­to-­detonation transition (DDT) hazard at any temperature. This is a significant statement since it removes detonative outcome concerns from the majority of insult scenarios on TATB-­based charges. It does not address the response of included detonator and booster assemblies, the response of which must be considered separately.

36 MATERIALS SCIENCE↗

Modeling, Analysis, and Control of Demand Response Resources

While the traditional goal of an electric power system has been to control supply to fulfill demand, the demand-side can plan an active role in power systems via Demand Response (DR), defined by the Department of Energy (DOE) as “a tariff or program established to motivate changes in electric use by end-use customers in response to changes in the price of electricity over time, or to give incentive payments designed to induce lower electricity use at times of high market prices or when grid reliability is jeopardized” [29]. DR can provide a variety of benefits including reducing peak electric loads when the power system is stressed and fast timescale energy balancing. Therefore, DR can improve grid reliability and reduce wholesale energy prices and their volatility. This dissertation focuses on analyzing both recent and emerging DR paradigms. Recent DR programs have focused on peak load reduction in commercial buildings and industrial facilities (C&I facilities). We present methods for using 15-minute-interval electric load data, commonly available from C&I facilities, to help building managers understand building energy consumption and ‘ask the right questions’ to discover opportunities for DR. Additionally, we present a regression-based model of whole building electric load, i.e., a baseline model, which allows us to quantify DR performance. We use this baseline model to understand the performance of 38 C&I facilities participating in an automated dynamic pricing DR program in California. In this program, facilities are expected to exhibit the same response each DR event. We find that baseline model error makes it difficult to precisely quantify changes in electricity consumption and understand if C&I facilities exhibit event-to-event variability in their response to DR signals. Therefore, we present a method to compute baseline model error and a metric to determine how much observed DR variability results from baseline model error rather than real variability in response. We find that, in general, baseline model error is large. Though some facilities exhibit real DR variability, most observed variability results from baseline model error. In some cases, however, aggregations of C&I facilities exhibit real DR variability, which could create challenges for power system operation. These results have implications for DR program design and deployment. Emerging DR paradigms focus on faster timescale DR. Here, we investigate methods to coordinate aggregations of residential thermostatically controlled loads (TCLs), including air conditioners and refrigerators, to manage frequency and energy imbalances in power systems. We focus on opportunities to centrally control loads with high accuracy but low requirements for sensing and communications infrastructure. Specifically, we compare cases when measured load state information (e.g., power consumption and temperature) is 1) available in real time; 2) available, but not in real time; and 3) not available. We develop Markov Chain models to describe the temperature state evolution of heterogeneous populations of TCLs, and use Kalman filtering for both state and joint parameter/state estimation. We present a look-ahead proportional controller to broadcast control signals to all TCLs, which always remain in their temperature dead-band. Simulations indicate that it is possible to achieve power tracking RMS errors in the range of 0.26–9.3% of steady state aggregated power consumption. Results depend upon the information available for system identification, state estimation, and control. We find that, depending upon the performance required, TCLs may not need to provide state information to the central controller in real time or at all. We also estimate the size of the TCL potential resource; potential revenue from participation in markets; and break-even costs associated with deploying DR-enabling technologies. We find that current TCL energy storage capacity in California is 8–11 GWh, with refrigerators contributing the most. Annual revenues from participation in regulation vary from $10 to $220 per TCL per year depending upon the type of TCL and climate zone, while load following and arbitrage revenues are more modest at $2 to $35 per TCL per year. These results lead to a number of policy recommendations that will make it easier to engage residential loads in fast timescale DR.

32 ENERGY CONSERVATION, CONSUMPTION, AND UTILIZATI↗

Compact Buried Ducts in a Hot-Humid Climate House

"9A system of compact, buried ducts provides a high-performance and cost-effective solution for delivering conditioned air throughout the building. This report outlines research activities that are expected to facilitate adoption of compact buried duct systems by builders. The results of this research would be scalable to many new house designs in most climates and markets, leading to wider industry acceptance and building code and energy program approval. The primary research question with buried ducts is potential condensation at the outer jacket of the duct insulation in humid climates during the cooling season. Current best practices for buried ducts rely on encapsulating the insulated ducts with closed-cell spray polyurethane foam insulation to control condensation and improve air sealing. The encapsulated buried duct concept has been analyzed and shown to be effective in hot-humid climates. The purpose of this project is to develop an alternative buried duct system that performs effectively as ducts in conditioned space - durable, energy efficient, and cost-effective - in a hot-humid climate (IECC warm-humid climate zone 3A) with three goals that distinguish this project: 1) Evaluation of design criteria for buried ducts that use common materials and do not rely on encapsulation using spray foam or disrupt traditional work sequences; 2) Establishing design criteria for compact ducts and incorporate those with the buried duct criteria to further reduce energy losses and control installed costs; 3) Developing HVAC design guidance for performing accurate heating and cooling load calculations for compact buried ducts.

32 ENERGY CONSERVATION, CONSUMPTION, AND UTILIZATI↗

Managing Army Plug Load Equipment Energy Use: Vending Machines

Vending machines consume the most energy of individual plug load devices common to Army buildings. As a group, they rank fourth in total electricity consumption, behind only clothes dryers, laptop computers, and telecom loads. Upgrading 80% of the estimated 22,000 refrigerated vending machines on Army installations to the latest ENERGY STAR ® performance and optimizing their efficiency settings could save 31 million kWh and $2 million per year.

32 ENERGY CONSERVATION, CONSUMPTION, AND UTILIZATI↗

Fracture Test Methods for Plastically Responding COPV Liners

An experimental procedure for evaluating the validity of using uniaxial tests to provide a conservative bound on the fatigue crack growth rate behavior small cracks in bi-axially loaded Composite Overwrapped Pressure Vessel (COPV) liners is described. The experimental procedure included the use of a laser notch to quickly generate small surface fatigue cracks with the desired size and aspect ratios. An out-of-plane constraint system was designed to allow fully reversed, fully plastic testing of thin sheet uniaxial coupons. Finally, a method was developed to determine to initiate small cracks in the liner of COPVs.

Dawicke, David S.↗

System and method to determine electric motor efficiency using an equivalent circuit

A system and method for determining electric motor efficiency includes a monitoring system having a processor programmed to determine efficiency of an electric motor under load while the electric motor is online. The determination of motor efficiency is independent of a rotor speed measurement. Further, the efficiency is based on a determination of stator winding resistance, an input voltage, and an input current. The determination of the stator winding resistance occurs while the electric motor under load is online.

32 ENERGY CONSERVATION, CONSUMPTION, AND UTILIZATI↗

Split radiator design for heat rejection optimization for a waste heat recovery system

A cooling system provides improved heat recovery by providing a split core radiator for both engine cooling and condenser cooling for a Rankine cycle (RC). The cooling system includes a radiator having a first cooling core portion and a second cooling core portion. An engine cooling loop is fluidly connected the second cooling core portion. A condenser of an RC has a cooling loop fluidly connected to the first cooling core portion. A valve is provided between the engine cooling loop and the condenser cooling loop adjustably control the flow of coolant in the condenser cooling loop into the engine cooling loop. The cooling system includes a controller communicatively coupled to the valve and adapted to determine a load requirement for the internal combustion engine and adjust the valve in accordance with the engine load requirement.

32 ENERGY CONSERVATION, CONSUMPTION, AND UTILIZATI↗

Optimal Operation of a Hybrid Hydraulic Electric Architecture (HHEA) for Off-Road Vehicles Over Discrete Operating Decisions

Many off-highway machines including construction and agriculture equipment use hydraulics for power transmission and throttling as a means for control. Trends towards better efficiency and electrification have led to the creation of a novel Hybrid Hydraulic-Electric Architecture (HHEA) which could significantly reduce energy consumption and maintain control performance, even in machines that are too large to be directly electrified. This is achieved by using a set of common pressure rails to transmit the majority of power via power dense hydraulics and modulating the power with small electric motor-drives to achieve precise control. This paper proposes a computationally efficient method for computing the optimal sequence of pressure rail selections for the HHEA over finite drive cycles. This is useful for fairly comparing the novel architecture’s energy performance to existing architectures and for use in iterative optimal design of the architecture. The optimal control technique makes use of a static model of the architecture and losses. Constraints are enforced such that the drive cycle is repeatable. The constrained optimal operation is solved using a Lagrange multiplier technique that transforms the optimization into a small set of sub-problems by considering combinations of active constraints. Each of these sub-problems can be solved efficiently because loss calculations for all time steps can be computed in parallel. A case study of an off-road construction machine demon-strates that the HHEA reduces energy consumption by 2/3 compared to the baseline load sensing architecture.

32 ENERGY CONSERVATION, CONSUMPTION, AND UTILIZATI↗

Open-air Demolition: Validation of EPA Approved Alternative Method for Emission Estimation - 19397

Emissions from open-air demolition of US Department of Energy (DOE) facilities are regulated by the US Environmental Protection Agency (EPA) under 40 CFR 61 subpart H. This regulation requires that facilities estimate emissions using an EPA approved method from activities such as open-air demolition prior to commencing the activity. Should those emissions exceed certain thresholds, the facility may be required to obtain an Approval to Construct or Modify the facility and/or installed monitoring methods meeting methods acceptable to EPA. There are no EPA approved methods that are specific to open-air demolition methods. For this project the DOE and CH2M Hill BWXT elected to prepare an alternative method specific to open-air demolition. EPA conditionally approved the method but required validation of the method during the demolition of the Vitrification Facility at the West Valley Demonstration Project (WVDP) before use for open-air demolition at other WVDP structures. The validation method included detailed source characterization, close-in ambient samplers, and a comparison of measured results to predicted emissions using AERMOD (American Meteorological Society (AMS) and U.S. Environmental Protection Agency (EPA) Regulatory Model). The methods evaluated include hydraulic hammers, mechanical shears, load out of waste and handling of the debris piles. The validation method involved the collection and analysis of ambient air samples from air samplers located at strategic locations within the projected plume path of the demolition activities. The analytical results from the air samplers were then compared to ambient air concentrations predicted at the sampler locations with the EPA model AERMOD. The input to the AERMOD software is a source term developed weekly using the alternative method and material at risk disturbed during each week. To account for the building wake effects of the surrounding structures, virtual point sources were developed in the AERMOD model and placed at the locations of the demolition, debris piles, debris handling and load out areas. It was found that the factors used for hydraulic hammering were extremely conservative and that emissions from the debris pile were not only the primary emission source, but that the moisture content of the debris pile and the wind speed were critical factors that must be considered in future open-air demolition projects. Based on the results of the validation process, adjustments were made to the alternative method. The final validated alternative method provides an approach for estimating airborne emissions from open-air demolition methods and techniques. The method will be used in lieu of 40 CFR 61 Appendix D to estimate emissions from future open-air demolition projects at the WVDP. (authors)

12 MANAGEMENT OF RADIOACTIVE AND NON-RADIOACTIVE W↗

Paths Forward: Approaches to Achieve Plug and Process Load Efficiency and Control in Commercial Buildings: Preprint

To accomplish net-zero carbon in the built environment by 2050, we must equitably decarbonize commercial buildings, which includes reducing plug and process loads (PPLs). PPLs are plug-in or hardwired electric and gas loads that are not directly associated with major building end uses like lighting and heating, ventilating, and air conditioning. PPLs account for a growing portion of U.S. commercial building energy consumption. Although commercial building PPL strategies and technologies are available today, they have not been adopted at a level sufficient to achieve significant savings and load flexibility across the building stock. In our "Pathways to Plug and Process Load Efficiency and Control" study, we investigated why these technologies and strategies have not seen widespread adoption and identified five behavior and technology pathways to increase PPL reduction in commercial buildings. In this paper, we expand beyond identifying the pathways and discuss approaches for achieving them. We discuss the importance of collecting and sharing data and case studies on PPL energy consumption and savings from control technology implementation, including code-required measures, for increasing adoption. Centralizing case studies and data, engaging industry organizations, and promoting awareness of PPL efficiency benefits to relevant groups are also key approaches. Additionally, funding, incentives, and rebate programs play important roles in driving PPL efficiency and control adoption. Finally, we discuss integrating PPL efficiency into broader company goals, such as environmental, social and governance (ESG) strategies and green building certifications, to further drive adoption.

adoption pathways↗

Cross-cutting strategies to lower electricity use of miscellaneous electric loads in the domestic sector

Miscellaneous Electric Loads (MELs) account for roughly one quarter of building electricity use in most developed countries. A product-specific approach to lowering MELs electricity use in this category takes too long and costs too much because there are so many MELs, each providing unique services. An alternative approach focusing on key functionalities was therefore explored. These functionalities include: (1) power management, (2) power scaling, and (3) power conversion. Cross-cutting efficiency improvements to these functionalities can be incorporated into broad categories of MELs, thus saving electricity and lowering costs. Even though the population of MELs is diverse and rapidly evolving, major technical opportunities exist to improve their efficiency in these functionalities. Research into energy-saving solutions within the cross-cutting technologies will probably have larger savings than focusing on single products.

32 ENERGY CONSERVATION, CONSUMPTION, AND UTILIZATI↗

Methods for Analyzing Electric Load Shape and its Variability

Current methods of summarizing and analyzing electric load shape are discussed briefly and compared. Simple rules of thumb for graphical display of load shapes are suggested. We propose a set of parameters that quantitatively describe the load shape in many buildings. Using the example of a linear regression model to predict load shape from time and temperature, we show how quantities such as the load?s sensitivity to outdoor temperature, and the effectiveness of demand response (DR), can be quantified. Examples are presented using real building data.

32 ENERGY CONSERVATION, CONSUMPTION, AND UTILIZATI↗

Cleanroom Energy Efficiency: Metrics and Benchmarks

Cleanrooms are among the most energy-intensive types of facilities. This is primarily due to the cleanliness requirements that result in high airflow rates and system static pressures, as well as process requirements that result in high cooling loads. Various studies have shown that there is a wide range of cleanroom energy efficiencies and that facility managers may not be aware of how energy efficient their cleanroom facility can be relative to other cleanroom facilities with the same cleanliness requirements. Metrics and benchmarks are an effective way to compare one facility to another and to track the performance of a given facility over time. This article presents the key metrics and benchmarks that facility managers can use to assess, track, and manage their cleanroom energy efficiency or to set energy efficiency targets for new construction. These include system-level metrics such as air change rates, air handling W/cfm, and filter pressure drops. Operational data are presented from over 20 different cleanrooms that were benchmarked with these metrics and that are part of the cleanroom benchmark dataset maintained by Lawrence Berkeley National Laboratory (LBNL). Overall production efficiency metrics for cleanrooms in 28 semiconductor manufacturing facilities in the United States and recorded in the Fabs21 database are also presented.

32 ENERGY CONSERVATION, CONSUMPTION, AND UTILIZATI↗

How Solar and Storage Can Reduce Coincident Peak Loads and Payments: A Case Study in Austin, TX

This study builds a generalized tool to forecast the change of 4 coincident peak (4CP) loads and payments based on varying amounts of solar, storage capacity, and population estimates over a 10-year period for utilities within the Electric Reliability Council of Texas (ERCOT). It also incorporates an optimization model for the energy storage systems (ESSs) that maximizes the sum of the revenue earned from their operation as well as the net 4CP payments received by the utility by attempting to arbitrage the ERCOT energy market. Here, the tool is illustrated by using empirical data from the municipally-owned utility in Austin, TX (Austin Energy). 4CP payments can be on the order of tens of millions of dollars. Results indicate that solar and storage capacity can substantially lower these payments. For example, a 20 MW increase in solar capacity in 2018 would reduce Austin Energy’s payment by an estimated $200,000 for each subsequent year. By using the novel approach of incorporating coincident peak demand charge reductions at the DSP level, this study highlights the economic value of local generation and storage.

14 SOLAR ENERGY↗

The Role of Energy Storage in Commercial Building

Motivation and Background of Study This project was motivated by the need to understand the full value of energy storage (thermal and electric energy storage) in commercial buildings, the opportunity of benefits for building operations and the potential interactions between a building and a smart grid infrastructure. On-site or local energy storage systems are not new to the commercial building sector; they have been in place in US buildings for decades. Most building-scale storage technologies are based on thermal or electrochemical storage mechanisms. Energy storage technologies are not designed to conserve energy, and losses associated with energy conversion are inevitable. Instead, storage provides flexibility to manage load in a building or to balance load and generation in the power grid. From the building owner's perspective, storage enables load shifting to optimize energy costs while maintaining comfort. From a grid operations perspective, building storage at scale could provide additional flexibility to grid operators in managing the generation variability from intermittent renewable energy resources (wind and solar). To characterize the set of benefits, technical opportunities and challenges, and potential economic values of storage in a commercial building from both the building operation's and the grid operation's view-points is the key point of this project. The research effort was initiated in early 2010 involving Argonne National Laboratory (ANL), the National Renewable Energy Laboratory (NREL), and Pacific Northwest National Laboratory (PNNL) to quantify these opportunities from a commercial buildings perspective. This report summarizes the early discussions, literature reviews, stakeholder engagements, and initial results of analyses related to the overall role of energy storage in commercial buildings. Beyond the summary of roughly eight months of effort by the laboratories, the report attempts to substantiate the importance of active DOE/BTP R&D activities in this space.

14 SOLAR ENERGY↗

Modeling, control, and dynamic performance analysis of a reverse osmosis desalination plant integrated within hybrid energy systems

An RO (reverse osmosis) desalination plant is proposed as an effective, FLR (flexible load resource) to be integrated into HES (hybrid energy systems) to support various types of ancillary services to the electric grid, under variable operating conditions. To study the dynamic (transient) analysis of such system, among the various unit operations within HES, special attention is given here to the detailed dynamic modeling and control design of RO desalination process with a spiral-wound membrane module. The model incorporates key physical phenomena that have been investigated individually into a dynamic integrated model framework. In particular, the solution-diffusion model modified with the concentration polarization theory is applied to predict RO performance over a large range of operating conditions. Simulation results involving several case studies suggest that an RO desalination plant, acting as a FLR, can provide operational flexibility to participate in energy management at the utility scale by dynamically optimizing the use of excess electrical energy. Here, the incorporation of additional commodity (fresh water) produced from a FLR allows a broader range of HES operations for maximizing overall system performance and profitability. For the purpose of assessing the incorporation of health assessment into process operations, an online condition monitoring approach for RO membrane fouling supervision is addressed in the case study presented.

32 ENERGY CONSERVATION, CONSUMPTION, AND UTILIZATI↗

Energy Implications of Economizer Use in California Data Centers

In the US, data center operations currently account for about 61 billion kWh/y of electricity consumption, which is more than 1.5percent of total demand. Data center energy consumption is rising rapidly, having doubled in the last five years. A substantial portion of data-center energy use is dedicated to removing the heat generated by the computer equipment. Data-center cooling load might be met with substantially reduced energy consumption with the use of air-side economizers. This energy saving measure, however, has been shown to expose servers to an order-of-magnitude increase in indoor particle concentrations with an unquantified increase in the risk of equipment failure. An alternative energy saving option is the use of water-side economizers, which do not affect the indoor particle concentration but require additional mechanical equipment and tend to be less beneficial in high humidity areas. Published research has only presented qualitative benefits of economizer use, providing industry with inadequate information on which to base their design decisions. Energy savings depend on local climate and the specific building-design characteristics. In this paper, based on building energy models, we report energy savings for air-side and water-side economizer use in data centers in several climate zones in California. Results show that in terms of energy savings, air-side economizers consistently outperform water-side economizers, though the performance difference varies by location. Model results also show that conventional humidity restrictions must by relaxed or removed to gain the energy benefits of air-side economizers.

32 ENERGY CONSERVATION, CONSUMPTION, AND UTILIZATI↗

Development and Clustering of Rate-Oriented Load Metrics for Customer Price-Plan Analysis: Preprint

One of the few methods electric utilities can use to motivate and change customer energy consumption is through their retail rate structures. Utilities are increasingly moving towards more dynamic rate-plans to achieve the objectives of motivating energy conservation, increasing self-consumption from onsite renewable generation, reducing peak demand and to flattening the demand profiles. This paper presents a set of rate-oriented customer load metrics that are the determinants of customers bill under four unique rate-plans. These metrics are not only indicative of which rate structure a customer should choose based on their load profiles, but also convey useful information about load consumption behavior. With these metrics, the utility can analyze their customers and identify customer classes that are rewarded under each rate-plan. This can help inform utilities whether the customer profiles being rewarded under each rate-plans are meeting their original objectives. To develop these customer classes, we calculate these rate-oriented load metrics for each customer and perform k-means clustering. The analysis is conducted on from a set of 300 customer profiles, examining the impact of four different rate-plans, different numbers of clusters and looking at customer bills and cluster load profile characteristics.

24 POWER TRANSMISSION AND DISTRIBUTION↗