Engineering Papers⌕ Search

SEARCH · Engineering Papers

Results for “coherent detection”

Search indexed NASA NTRS and DOE OSTI research on propulsion, heat transfer, battery materials and energy systems. Follow report and document links to the original sources.

Quote a phrase for an exact phrase match. Source license links do not imply unrestricted reuse.

At least 433 records · Page 24

Design and characterization of a phonon-mediated cryogenic particle detector with an eV-scale threshold and 100 keV-scale dynamic range

We present the design and characterization of a cryogenic phonon-sensitive Si detector exploiting the Neganov-Tromov-Luke effect to detect single-charge excitations. This device achieved 2.65(2) eV phonon energy resolution when operated without a voltage bias across the crystal and a corresponding charge resolution of 0.03 electron-hole pairs at 100 V bias. With a continuous-readout data acquisition system and an oine optimum-filter trigger, we obtain a 9.2 eV threshold with a trigger rate of the order of 20 Hz. The detector's energy scale is calibrated up to 120 keV using an energy estimator based on the pulse area. The high performance of this device allows its application to different fields where excellent energy resolution, low threshold, and large dynamic range are required, including dark matter searches, precision measurements of coherent neutrino-nucleus scattering, and ionization yield measurements.

Ren, R↗

Forward Modeling the Orbits of Companions to Pulsating Stars from Their Light Travel Time Variations

Mutual gravitation between a pulsating star and an orbital companion leads to a time-dependent variation in path length for starlight traveling to Earth. These variations can be used for coherently pulsating stars, such as the δ Scuti variables, to constrain the masses and orbits of their companions. Observing these variations for δ Scuti stars has previously relied on subdividing the light curve and measuring the average pulsation phase in equally sized subdivisions, which leads to undersampling near periapsis. We introduce a new approach that simultaneously forward models each sample in the light curve and show that this method improves upon current sensitivity limits—especially in the case of highly eccentric and short-period binaries. We find that this approach is sensitive enough to observe Jupiter mass planets around δ Scuti stars under ideal conditions, and use gravity-mode pulsations in the subdwarf B star KIC 7668647 to detect its companion without radial velocity data. We further provide robust detection limits as a function of the signal-to-noise ratio of the pulsation mode and determine that the minimum detectable light travel time amplitude for a typical Kepler δ Scuti is around 2 s. This new method significantly enhances the application of light travel time variations to detecting short-period binaries with pulsating components, and pulsating A-type exoplanet host stars, especially as a tool for eliminating false positives.

79 ASTRONOMY AND ASTROPHYSICS↗

Design and Characterization of a Phonon-Mediated Cryogenic Particle Detector with an eV-Scale Threshold and 100 keV-Scale Dynamic Range

We present the design and characterization of a cryogenic phonon-sensitive Si detector exploiting the Neganov-Trofimov-Luke effect to detect single-charge excitations. This device achieved 2.65(2) eV phonon energy resolution when operated without a voltage bias across the crystal and a corresponding charge resolution of 0.03 electron-hole pairs at 100 V bias. With a continuous-readout data acquisition system and an offline optimum-filter trigger, we obtain a 9.2 eV threshold with a trigger rate of the order of 20 Hz. The detector's energy scale is calibrated up to 120 keV using an energy estimator based on the pulse area. The high performance of this device allows its application to different fields where excellent energy resolution, low threshold, and large dynamic range are required, including dark matter searches, precision measurements of coherent neutrino-nucleus scattering, and ionization yield measurements.

46 INSTRUMENTATION RELATED TO NUCLEAR SCIENCE AND ↗

Multi-qubit nanoscale sensing with entanglement as a resource

Nitrogen vacancy (NV) centres in diamond are widely deployed as local magnetic sensors, using single-qubit control to measure both time-averaged fields and noise with nanoscale spatial resolution. Moving beyond single qubits to multi-qubit control enables new sensing modalities such as measuring nonlocal spatiotemporal correlators or using entangled states to enhance measurement sensitivity. Here, in this work, we describe protocols for using optically unresolved NV centre pairs and nuclear spins as multi-qubit sensors for measuring correlated noise at nanometre length scales. For noninteracting NV centres, we implement a phase-cycling protocol that disambiguates magnetic correlations from variance fluctuations, leveraging the presence of a third qubit, a 13 C nucleus, to effect coherent single-NV spin flips and enable phase cycling even for co-aligned NV centres that are spectrally unresolved. For length scales around 10 nm, we create maximally entangled Bell states through dipole–dipole coupling between two NV centres and use these entangled states to directly read out the magnetic field correlation, rather than reconstructing it from independent measurements of unentangled NV centres. Importantly, this changes the scaling of sensitivity with readout noise from quadratic to linear. For conventional off-resonant readout of the NV centre spin state (for which the readout noise is roughly 30 times the quantum projection limit), this results in more than an order of magnitude improvement in sensitivity. Finally, we demonstrate methods for detecting high spatial- and temporal-resolution correlators with pairs of strongly interacting NV centres.

condensed-matter physics↗

CHESS: The future direct geometry spectrometer at the second target station

CHESS, chopper spectrometer examining small samples, is a planned direct geometry neutron chopper spectrometer designed to detect and analyze weak signals intrinsic to small cross sections (e.g., small mass, small magnetic moments, or neutron absorbing materials) in powders, liquids, and crystals. CHESS is optimized to enable transformative investigations of quantum materials, spin liquids, thermoelectrics, battery materials, and liquids. The broad dynamic range of the instrument is also well suited to study relaxation processes and excitations in soft and biological matter. The 15 Hz repetition rate of the Second Target Station at the Spallation Neutron Source enables the use of multiple incident energies within a single source pulse, greatly expanding the information gained in a single measurement. Furthermore, the high flux grants an enhanced capability for polarization analysis. This enables the separation of nuclear from magnetic scattering or coherent from incoherent scattering in hydrogenous materials over a large range of energy and momentum transfer. This paper presents optimizations and technical solutions to address the key requirements envisioned in the science case and the anticipated uses of this instrument.

47 OTHER INSTRUMENTATION↗

Serendipitous Discovery of Three Millisecond Pulsars with the GMRT in Fermi-directed Survey and Follow-up Radio Timing

We report the discovery of three millisecond pulsars (MSPs): PSRs J1120–3618, J1646–2142, and J1828+0625 with the Giant Metrewave Radio Telescope (GMRT) at a frequency of 322 MHz using a 32 MHz observing bandwidth. These sources were discovered serendipitously while conducting the deep observations to search for millisecond radio pulsations in the directions of unidentified Fermi Large Area Telescope (LAT) γ-ray sources. We also present phase coherent timing models for these MSPs using ~5 yr of observations with the GMRT. PSR J1120–3618 has a 5.5 ms spin period and is in a binary system with an orbital period of 5.6 days and minimum companion mass of 0.18 M ⊙ , PSR J1646–2142 is an isolated object with a spin period of 5.8 ms, and PSR J1828+0625 has a spin period of 3.6 ms and is in a binary system with an orbital period of 77.9 days and minimum companion mass of 0.27 M ⊙ . The two binaries have very low orbital eccentricities, in agreement with expectations for MSP-helium white dwarf systems. Using the GMRT 607 MHz receivers having a 32 MHz bandwidth, we have also detected PSR J1646–2142 and PSR J1828+0625, but not PSR J1120–3618. PSR J1646–2142 has a wide profile, with significant evolution between 322 and 607 MHz, whereas PSR J1120–3618 exhibits a single peaked profile at 322 MHz and PSR J1828+0625 exhibits a single peaked profile at both the observing frequencies. These MSPs do not have γ-ray counterparts, indicating that these are not associated with the target Fermi LAT pointing emphasizing the significance of deep blind searches for MSPs.

79 ASTRONOMY AND ASTROPHYSICS↗

A holey cavity for single-transducer 3D ultrasound imaging with physical optimization

Within the compressive sensing (CS) framework, one effective way to increase the likelihood of successful signal reconstruction is to employ random processes in the construction of the sensing matrix. This work presents a 3D holey cavity, with diverse frequency modes, to spectrally code, that is, randomize, the ultrasound wave fields. The simulated results show that the use of such a cavity enables imaging simple or complex targets, such as spheres or the letter E, by only a single transceiver—something that is not possible without the use of a coding structure like the cavity. The effect of noise on imaging results and the size of the targets on the first-order Born approximation (BA) are also investigated. Moreover, this study attempts to optimize the cavity, based on a single numerical metric, such as the sum of singular values (SSV) or mutual coherence (MC). Yet, it will be shown that neither of these metrics can consistently compare the norm-one imaging performance between two cavities of different materials or hole sizes. This leaves finding a quantitative metric for these kinds of optimizations an open problem.

42 ENGINEERING↗

Observations of Mantle Seismic Anisotropy Using Array Techniques: Shear-Wave Splitting of Beamformed SmKS Phases

Shear-wave splitting measurements are commonly used to resolve seismic anisotropy in both the upper and lowermost mantle. Typically, such techniques are applied to SmKS phases that have reflected (m-1) times off the underside of the core-mantle boundary before being recorded. Practical constraints for shear-wave splitting studies include the limited number of suitable phases as well as the large fraction of available data discarded because of poor signal-to-noise ratios (SNRs) or large measurement uncertainties. Array techniques such as beamforming are commonly used in observational seismology to enhance SNRs, but have not been applied before to improve SmKS signal strength and coherency for shear wave splitting studies. Here, we investigate how a beamforming methodology, based on slowness and backazimuth vespagrams to determine the most coherent incoming wave direction, can improve shear-wave splitting measurement confidence intervals. Through the analysis of real and synthetic seismograms, we show that (a) the splitting measurements obtained from the beamformed seismograms (beams) reflect an average of the single-station splitting parameters that contribute to the beam; (b) the beams have (on average) more than twice as large SNRs than the single-station seismograms that contribute to the beam; (c) the increased SNRs allow the reliable measurement of shear wave splitting parameters from beams down to average single-station SNRs of 1.3. Beamforming may thus be helpful to more reliably measure splitting due to upper mantle anisotropy. Moreover, here we show that beamforming holds potential to greatly improve detection of lowermost mantle anisotropy by demonstrating differential SKS–SKKS splitting analysis using beamformed USArray data.

54 ENVIRONMENTAL SCIENCES↗

Nonlinear spectral analysis of ion acoustic solitons arising from a streaming charged object using the numerical inverse scattering transform

Observations of nonlinear coherent plasma phenomena in spacecraft and terrestrial experiments often rely on visual identification of solitary modes because nonlinear coherent modes are broadband in a Fourier transform based analysis. We implement an alternative spectral decomposition known as the inverse scattering transform and demonstrate its ability to successfully isolate nonlinear modes on the homogeneous and forced Korteweg–De Vries equation which models these nonlinear modes. We also demonstrate for the first time that this decomposition is useful when forcing is applied. This is because the stable modes generated by localized forcing are similar to the homogeneous solutions where the inverse scattering transform is a rigorous decomposition. This spectral technique is then applied to simulations of ion acoustic waves generated by a 10 mm spherical debris object interacting with the ionospheric plasma orbiting at 2000 km altitude. The algorithm is found to successfully detect the resultant solitons. This demonstrates the feasibility of using this spectral technique as a real time analysis tool for screening spacecraft data for nonlinear solitary modes.

70 PLASMA PHYSICS AND FUSION TECHNOLOGY↗

Nitrogen thermometry in an inductively coupled plasma torch using broadband nanosecond coherent anti-Stokes Raman scattering

The development of atmospheric hypersonic flight and re-entry capabilities requires the characterization of the thermo-chemical state of representative test environments. This study demonstrates the usage of multiplex nanosecond N 2 coherent anti-Stokes Raman scattering (CARS) to measure temperatures in an atmospheric, high-temperature (>6000K), air plasma plume, generated by an inductively coupled plasma torch. These are some of the highest temperatures ever accessed via gas-phase CARS, to our knowledge. Temperatures of N 2 in the equilibrium plasma plume are determined via theoretical fits to measured CARS spectra. We discuss the practical implementation of CARS at very high temperatures, including the scaling of the N 2 CARS signal strength from 300 to 6700 K, where the expected peak signal from the high-temperature plasma torch gases is two orders of magnitude less than commonly encountered in combustion environments. An intensified CCD camera enables single-laser-shot detection at temperatures as high as 6200 K, by increasing sensitivity and providing a time gate against intense background luminosity. We also discuss the impacts of unwanted two-beam CARS contributions from outside the nominal three-beam measurement volume. We present mean axial and radial temperature profiles, as well as time-series data derived from both single-laser-shot and accumulated CARS spectra. The single-laser-shot precision is 1.7%–2.6% at temperatures of 3500 to 6200 K. The presented results pave the way for the use of CARS at very high temperatures and the measurement of spatially resolved interface processes in high-enthalpy flows.

Fries, Dan (ORCID:0000000229513294)↗

Online and Offline Data Quality Monitoring for the Mu2e Calorimeter

This thesis presents the design, implementation, and validation of a calorimeter Data Quality Monitoring (DQM) toolchain for the Mu2e experiment at Fermilab. Mu2e searches for charged lepton flavor violation via coherent muon-to-electron conversion in the field of an aluminum nucleus, $\mu^- Al \rightarrow e^-Al$, a process whose observation would constitute clear evidence of physics beyond the Standard Model. Achieving target sensitivity requires stringent control of detector performance and data integrity during acquisition, as subtle issues in readout configuration, data formatting, or electronics behavior can compromise reconstruction and bias downstream analyzes. To address these challenges, this work develops a multi-layer DQM approach spanning both raw data validation and reconstructed digi-level diagnostics. At the low level, a fragment analysis component performs word- and bit-field decoding of calorimeter readout blocks, enabling sanity checks of the expected structure and producing detailed error and integrity statistics useful for commissioning and troubleshooting. At the digi level, the CaloDigiDQM analyzer is implemented within the art framework and transforms each CaloDigiCollection into a structured hierarchy of ROOT histograms designed for fast drill-down diagnostics. The module generates coherent monitoring views at global, disk, board, and channel granularity, including occupancy, waveform-derived features (baseline, RMS, peak amplitude and position), and left-right sensor consistency metrics. Detector-aware channel-to-electronics mapping is performed through the conditions system (CaloDAQMap), ensuring that diagnostics remain aligned with hardware identifiers used in operations. For end-to-end testing without reliance on live DAQ data, a synthetic CaloDigi producer is developed to generate realistic waveforms with controlled noise and pulse shapes. The resulting system supports both offline ROOT-file production and online operation, including optional histogram streaming through otsdaq via ots::HistoSender. This toolchain provides a practical and scalable foundation for calorimeter commissioning and stable data collection, enabling early detection of anomalies and reducing operational risk for Mu2e.

Vakulenko, Mark [Drew U.] (ORCID:0009000276197818)↗

Mitigation of nitrogen vacancy photoluminescence quenching from material integration for quantum sensing

The nitrogen-vacancy (NV) color center in diamond has demonstrated great promise in a wide range of quantum sensing. Recently, there have been a series of proposals and experiments using NV centers to detect spin noise of quantum materials near the diamond surface. This is a rich complex area of study with novel nano-magnetism and electronic behavior, that the NV center would be ideal for sensing. However, due to the electronic properties of the NV itself and its host material, getting high quality NV centers within nanometers of such systems is challenging. Band bending caused by space charges formed at the metal-semiconductor interface force the NV center into its insensitive charge states. Here, we investigate optimizing this interface by depositing thin metal films and thin insulating layers on a series of NV ensembles at different depths to characterize the impact of metal films on different ensemble depths. We find an improvement of coherence and dephasing times we attribute to ionization of other paramagnetic defects. The insulating layer of alumina between the metal and diamond provide improved photoluminescence and higher sensitivity in all modes of sensing as compared to direct contact with the metal, providing as much as a factor of 2 increase in sensitivity, decrease of integration time by a factor of 4, for NV T 1 relaxometry measurements.

36 MATERIALS SCIENCE↗

Optimizing infrasound observations for sample return capsule re-entry: Insights from OSIRIS-REx and Hayabusa2

The atmospheric entry of meteoroids presents a rare and unpredictable phenomenon, posing challenges for systematic observation and detailed characterization. Such events are nonetheless critical for advancing understanding of acoustic wave propagation, atmospheric structure, and entry dynamics. In contrast, sample return capsules (SRCs) from space missions follow well constrained re-entry trajectories, enabling planned observations of shock wave generation and propagation under controlled conditions. This study compares two SRC atmospheric entries, Hayabusa2 in 2020 and OSIRIS-REx in 2023, to assess how different infrasound array configurations influence shock wave detection and trajectory validation. Hayabusa2’s re-entry was monitored using a distributed network of 28 portable infrasound sensors across seven arrays in Woomera, Australia, permitting three-dimensional reconstruction of the trajectory and analysis of wave characteristics. For OSIRIS-REx, a compact four-sensor array deployed near Eureka Airport provided trajectory confirmation through arrival-time differences and back-azimuth estimates. Spectral and waveform analyses revealed differences in signal properties associated with variations in entry angle and velocity. The results illustrate both the strengths and the limitations of the deployed array configurations. The dense and distributed arrays during Hayabusa2’s re-entry enabled detailed trajectory reconstruction, whereas the compact array at Eureka primarily provided confirmation of signal coherence and back-azimuth consistency. These case studies highlight that even relatively small arrays, if located close to the predicted ground track, can still capture useful information on arrival direction and timing. Such insights provide practical guidance for planning future observational campaigns of SRC returns and other controlled atmospheric entries, and may also inform approaches to opportunistic observations of meteoroid events and other atmospheric acoustic phenomena.

celestial mechanics: orbit determination↗

Probing electromagnetic nonreciprocity with quantum geometry of photonic states

Reciprocal and nonreciprocal effects in dielectric and magnetic materials provide crucial information about the microscopic properties of electrons. However, experimentally distinguishing the two has proven to be challenging, especially when the associated effects are extremely small. To this end, we propose a contactless detection using a cross-cavity device where a material of interest is placed at its center. We show that the optical properties of the material, such as Kerr and Faraday rotation, or birefringence, manifest in the coupling between the cavity's electromagnetic modes and in the shift of their resonant frequencies. By calculating the dynamics of a geometrical photonic state, we formulate a measurement protocol based on the quantum metric and quantum process tomography that isolates the individual components of the material's complex refractive index and minimizes the quantum mechanical Cramér-Rao bound on the variance of the associated parameter estimation. Our approach is expected to be applicable across a broad spectrum of experimental platforms including Fock states in optical cavities, or coherent states in microwave and THz resonators. Published by the American Physical Society 2025

Petrides, Ioannis (ORCID:0000000174842444)↗

Data Summarization and Inference at Scale

This is the final report for the DOE ASCR grant SC-0022260, Data Summarization and Inference at Scale, PI: Alex Pothen, Purdue University. The goal of the project was to solve data-intensive and compute-intensive problems in the physical sciences, engineering, information science, data science, etc. by designing and implementing new algorithms that could work with a subset of the data. The four subgoals were: (a) The solution of problems where the data is too large to be stored in the memory of a computer. In this streaming model of computation, the data arrives as a stream of elements to the computer, each element is processed as it arrives, and a decision is made to discard the data or to store it; only a small subset of the data proportional to the size of the output solution is stored, and when all the data has been streamed, a solution to the problem is computed from the stored subset. (b) The use of machine learning methods to compute solutions to data-intensive problems. The use of GPUs is critical to obtain high performance on machine learning tasks, but their memory sizes are smaller relative to that of CPUs. For large-scale problems, the data is sampled many times, and small samples are used with repetition, for robustness, to compute solutions to inference tasks. This sampling reduces the memory required to solve the problem, but attention is needed to avoid slow convergence to the solutions, and reduced accuracy of inference. We propose submodular optimization, Large Language Models, and physics-informed neural networks to enable GPU computations here. (c) Modeling and visualization of high-dimensional data using interpretable features. Clinical proteomic data sets from immunology for the detection of cancer and other diseases are temporal and high-dimensional, and algorithms for visualizing these data sets using clinically interpretable features are lacking. We propose methods that compute distances based on the optimal transportation problem and graph edit distances to address this problem. We also propose the use of optimal transport-based distances, spatial statistics, and network structure to classify image data sets, We apply these algorithms to electron micrographs of the peripheral nervous system in the digestive tract. (d) The design of data-intensive algorithms on emerging architectures, specifically, noisy, intermediate-scale quantum (NISQ) devices. Quantum computers offer the possibility of exploring large solution spaces due to the principle of superposition, but current quantum computers are limited by few qubits, short coherence times due to noise, poor interconections among the qubits, etc. We propose the use of the divide and conquer paradigm to solve large-scale problems, wherein collections of small subproblems are solved on the quantum devices, and the solutions to the subproblems are integrated into a solution for the original problem on a classical computer.

97 MATHEMATICS AND COMPUTING↗

Efficient prediction of attosecond two-colour pulses from an X-ray free-electron laser with machine learning

Abstract X-ray free-electron lasers are sources of coherent, high-intensity X-rays with numerous applications in ultra-fast measurements and dynamic structural imaging. Due to the stochastic nature of the self-amplified spontaneous emission process and the difficulty in controlling injection of electrons, output pulses exhibit significant noise and limited temporal coherence. Standard measurement techniques used for characterizing two-coloured X-ray pulses are challenging, as they are either invasive or diagnostically expensive. In this work, we employ machine learning methods such as neural networks and decision trees to predict the central photon energies of pairs of attosecond fundamental and second harmonic pulses using parameters that are easily recorded at the high-repetition rate of a single shot. Using real experimental data, we apply a detailed feature analysis on the input parameters while optimizing the training time of the machine learning methods. Our predictive models are able to make predictions of central photon energy for one of the pulses without measuring the other pulse, thereby leveraging the use of the spectrometer without having to extend its detection window. We anticipate applications in X-ray spectroscopy using XFELs, such as in time-resolved X-ray absorption and photoemission spectroscopy, where improved measurement of input spectra will lead to better experimental outcomes.

71 CLASSICAL AND QUANTUM MECHANICS, GENERAL PHYSIC↗

LCLS RF Station Anomaly Candidates, SLAC, Nov 2020 to Dec 2020, Version 1

The data consists of radio-frequency (RF) station process variables (amplitude and amplitude-mean-out-of-tolerance bit) and beam position monitor (BPM) values for about a month of Linac Coherent Light Source (LCLS) time. The data is all from normal conducting hard X-ray operation. The dataset contains roughly 5000 anomaly “candidates.” For each candidate, we include 3.5 minutes of data from the 82 RF stations and ~20 seconds of data from 4 BPMs. We also include several CSV files with additional information and labels for each candidate.

43 PARTICLE ACCELERATORS↗

Tunable phononic quantum interference induced by two-dimensional metals

Harnessing quantum interference among bosons provides opportunities due to their longer coherence time than fermions. Fano resonance, an example of quantum interference between discrete and continuous states, is marked by an asymmetric lineshape. While photon-based Fano resonance has enabled high-sensitivity molecule sensing, phonon-based Fano resonance remains underexplored because of ineffective interference between discrete phonons and electronic continuum. In this work, we report phonon-based Fano resonance in a graphene/2D Ag/SiC heterostructure, arising from frequency and lifetime matching between discrete and continuous phonons of SiC. The observed Fano asymmetry is tunable over two orders of magnitude, surpassing previously reported phonon-based systems. The 2D Ag layer restructures the interfacial SiC and facilitates resonant scattering to enhance Fano asymmetry, which is unattainable in conventional Ag. We further demonstrated that this Fano resonance allows ultrasensitive molecule detection at the single-molecule level. Our work highlights phonon-based Fano resonance, opening avenues for engineering quantum interference with phonons.

Science & Technology - Other Topics↗