Engineering Papers⌕ Search

SEARCH · Engineering Papers

Results for “charge storage”

Search indexed NASA NTRS and DOE OSTI research on propulsion, heat transfer, battery materials and energy systems. Follow report and document links to the original sources.

Quote a phrase for an exact phrase match. Source license links do not imply unrestricted reuse.

418 records · Page 24

Polymer Composite Material Testing for a Cryotank Application

Composite cryotanks will play a key role in enabling the next generation of efficient aircraft. Carbon fiber reinforced polymer (CFRP) composites have the benefits of reduced weight and potentially higher structural strength compared to traditional metallic fuel tanks. A material screening study was conducted to inform material selection for liquid hydrogen (LH2) fuel storage. Three composite materials were considered because of their aerospace grade toughness, strength, and existing data to compare against. These materials were a thermoplastic low-melt polyaryletherketone (LM-PAEK)/carbon fiber (CF), thermoset/CF, and hybrid thermoset/thermoplastic polyurethane (TPU) veil/CF composite. Mechanical screening tests included tension, compression, in-plane shear (IPS), and tensile-tensile fatigue (TTF). Each material was tested at both a baseline (no liquid nitrogen/LN2 cycling) and 100 LN2-cycled conditions to determine the knockdown factor, if any, of each material when exposed to environmental loading effects in a cryotank. Results show minimal effects of the LN2-cycling compared against baseline values. The three materials behaved similarly in tension; however, the thermoplastic/CF had the highest IPS toughness. The hybrid thermoset/TPU/CF composite had the lowest IPS strength, compressive strength, and toughness. LN2-cycling had minimal effects on tensile-tensile fatigue performance of the thermoplastic/CF material. Mechanical data was captured to guide material down selection for future commercially viable hydrogen aircraft design. In its current state, there does not exist a consolidated, publicly available database for CFRP composite material performance data at cryogenic temperatures. The next step in this work is to test the thermoplastic and thermoset CFRP composites, as well as the neat resins, at LH2 relevant temperature (20 K) to capture this crucial material property data. These results are essential to inform cryotank design and modeling efforts. The process to start this next round of testing has begun. Planned mechanical tests include toughness (single-edge notched beam), tension (unidirectional and quasi-isotropic), thermal expansion, and thermal conductivity. Some tests will also be conducted at an intermediate temperature of 111 K relevant to liquid natural gas (LNG), another attractive fuel choice. The ultimate goal is to manufacture a sub-scale cryotank part that can pass relevant burst, fatigue, permeation, and thermal cycling tests. This work is a part of NASA’s Commercially viable Hydrogen Aircraft for Robust Growth in Efficiency (CHARGE) Project under the larger NASA Subsonic Vehicle Technologies and Tools (SVTT) Project.

composites↗

New Class of Flow Batteries for Terrestrial and Aerospace Energy Storage Applications

Future sustainable energy generation technologies such as photovoltaic and wind farms require advanced energy storage systems on a massive scale to make the alternate (green) energy options practical. The daunting requirements of such large-scale energy systems such as long operating and cycle life, safety, and low cost are not adequately met by state-of-the-art energy storage technologies such as vanadium flow cells, lead-acid, and zinc-bromine batteries. Much attention is being paid to redox batteries specifically to the vanadium redox battery (VRB) due to their simplicity, low cost, and good life characteristics compared to other related battery technologies. NASA is currently seeking high-specific- energy and long-cycle-life rechargeable batteries in the 10-to-100-kW range to support future human exploration missions, such as planetary habitats, human rovers, etc. The flow batteries described above are excellent candidates for these applications, as well as other applications that propose to use regenerative fuel cells. A new flow cell technology is proposed based on coupling two novel electrodes in the form of solvated electron systems (SES) between an alkali (or alkaline earth) metal and poly aromatic hydrocarbons (PAH), separated by an ionically conducting separator. The cell reaction involves the formation of such SES with a PAH of high voltage in the cathode, while the alkali (or alkaline earth metal) is reduced from such an MPAH complex in the anode half-cell. During recharge, the reactions are reversed in both electrodes. In other words, the alkali (alkaline earth) metal ion simply shuttles from one M-PAH complex (SES) to another, which are separated by a metal-ion conducting solid or polymer electrolyte separator. As an example, the concept was demonstrated with Li-naphthalene//Li DDQ (DDQ is 2,3-Dichloro-5,6-dicyano- 1,4-benzoquinone) separated by lithium super ion conductor, either ceramic or polymer (solid polymer or gel polymer) electrolytes. The reactants are Li-naphthalene dissolved in tetrahydrofuran (THF) with a lithium salt of 1M LiBF4 (lithium tetra fluoroborate) in the anode compartment, and DDQ again dissolved in THF and also containing 1M LiBF4 salt in the cathode half-cell. The solid electrolyte separator used in the first set of experiments is a ceramic solid electrolyte, available from a commercial source. The open circuit voltage of the cells is close to 3.0 V, as expected from the individual half-cell voltages of Li-naphthalene and Li-DDQ. Upon discharge, the cell shows steady discharge voltage of 2.7 V, which confirms that the electrochemical processes do involve lithium ion shuttling from the anodic compartment to the cathode half-cell. The reversibility or rechargeability is demonstrated by charging the partially discharged cells (i.e., with lithium present in the DDQ half). Once again, a steady voltage close to 3.0 V was observed during charge, indicating that the system is quite reversible. In the subsequent concept-demonstration studies, the ceramic electrolyte has been replaced with a gel polymer electrolyte, e.g., PVDF-HFP (poly vinylene difluoride hexafluoropropene) gel, which has several advantages such as high ionic conductivity (almost comparable to liquid electrolyte and about 2 orders of magnitude better than the ceramic equivalent), lower cost, and possibly higher chemical stability at the anode. In addition, it can be bonded to the electrode by thermal fusion to form membrane electrode assemblies (MEAs), as is done in fuel cells.

Bugga, Ratnakumar V.↗

Qualitative Headspace GCMS Analysis of Lunar Regolith and Volatile Simulant Mixtures

Introduction: Future Artemis missions aim to return the volatile-bearing samples collected near lunar polar craters. We, as advanced curation scientists, are responsible for developing techniques and methodologies for preserving the integrity of returned samples and the science value those samples contain. The extent to which that preservation is possible, and the trade-offs preservation requires (e.g. monetary costs, sample volume limitations) all must be considered. Even less-than pristine volatile-bearing samples will be of tremendous value to the scientific community seeking to unravel the history of lunar surface volatiles and, more broadly, volatiles in the solar system. A sample collected on the lunar surface will experience at least five distinctive periods during which any changes here referred to as “alteration” will certainly occur at some scale: collection on the lunar surface; transportation back to Earth; long-term storage; curatorial processing; and allocation/distribution. The Planetary Exploration and Astromaterials Research Lab (PEARL) seeks to understand temperature and pressure effects on returned volatile samples by working with high-fidelity volatile-containing regolith simulants, setting the foundation for the future of cold curation. This abstract is focused on gas-surface interactions between LCROSS volatiles and readily available lunar regolith simulants. Experiments involved analyzing differences in headspace gas composition for various combinations of volatile and regolith simulants using gas chromatography/mass spectrometry (GC/MS). Experimental Procedure: The volatile simulants were chosen based on the molecules detected during the LCROSS mission.1 Stock solutions of condensed lunar volatile analytes were: methanol, 7 N ammonia in methanol, and 0.4% hydrogen sulfide in water. The regolith simulants used were primarily JSC-1A and NU-LHT-4M. Additional regolith simulant control studies were conducted with <150 μm sieved sand and KBr. A nested vial sample preparation approach separated the liquid stock solutions from the regolith, eliminating potential matrix effects between liquid and solid phases. Fifteen microliter aliquots of liquid volatile simulants were added to a 2 mL liquid GC vial and capped in atmosphere. An 18G needle punctured the 2 mL GC vial immediately before being transferred and sealed in a 20 mL GC vial containing 0-0.3 g of regolith simulant, see Figure 1. Separating the analytes ensures any changes observed in the total headspace gases is a result of gas-surface and/or gas-gas interactions. Equipment and Method: Initial GC/MS method development for the separation and identification of relevant headspace gases can be found in Amick, et al. 2023.2 The only hardware change is a different column: a TG-1701MS 30 m × 0.25 mm × 1.00 μm column. The vials were sampled at 10°C, room temperature (~25°C) and 50°C. Low temperature samples were kept in a chilled autosampler stage for at least 1 hour prior to sampling. High temperature samples were agitated at 50°C for 5 minutes immediately prior to injection onto the column. Headspace chromatograms were collected for each combination of temperature, regolith, and volatile simulant, including controls without one or both types of analytes, in triplicate. The chromatogram elution window for each analyte or significant atmospheric gas was identified using the peak mass spectrum cross-referenced with Figure 1.Picture of the nested vial set-up. a NIST MS library search. Each analyte peak was integrated after filtering the mass spectrum trace for the parent or most unique mass-to-charge ratio. For example, the mass-to-charge ratio used to identify, filter for, and integrate the carbon dioxide peak was centered around 44 m/z. Results: Figure 2 shows the integrated peak area for hydrogen sulfide in all combinations of regolith simulants, temperatures, and the addition of ammonia in methanol solution. Multiple repeat experiments with H2S and regolith simulants have confirmed hydrogen sulfide is removed from the headspace within 1 hour when exposed to JSC-1A, NU-LHT-4M and sand (not pictured). The consumption of H2S by lunar regolith simulants at different temperatures indicates surface chemistry will be an integral component in sample integrity and preservation. It is important to note that while the effect of surface chemistry on gaseous hydrogen sulfide is intriguing, further investigation into more chemically accurate regolith simulants is necessary and ongoing. The sulfur in hydrogen sulfide is in its most reduced state while off-the-shelf, terrestrially sourced JSC-1A and NU-LHT-4M are more oxidized than most lunar materials,3which likely leads to different oxidation-reduction reactions than would be expected in lunar regolith. Figure 3 shows the integrated peak area of carbon dioxide for each sample combination that contained ammonia in methanol solution. The addition of ammonia to the GC vials results in a consistent and reproducible decrease in carbon dioxide gas, even at 50°C. The effect became more pronounced when JSC-1A or NU-LHT-4M were present. This set of experiments demonstrated that the sample composition will affect the chemical and physical state of each component present. Future spectroscopic and microscopy experiments will be geared towards identifying the cause for the CO2(g) concentration decrease and the consumption of hydrogen sulfide. As cold and volatile curation scientists, this information provides necessary insight on how to appropriately handle and analyze volatile bearing returned samples, as well as predict the effect chemical composition has on the various sample phases we will analyze upon return to Earth. Unlike traditional curation of geologic materials, the molecules in a sample cannot be identified or processed using the naked eye or even an optical microscope. Volatile curation will require a combination of analytical techniques, including but not limited to highly sensitive gas and solid/condensed phase spectroscopy. This set of experiments has demonstrated the need for more detailed studies of volatile mixtures with mineralogically and geochemically analogous lunar regolith simulants to prepare for the curation of volatile-rich lunar samples from the south polar region of the Moon. References: [1] Colaprete, A., et al. (2010) Science, 330, (463-468). [2] Amick, C. L., et al.(2023) Houston, Texas, [3] Heiken, G. H., et al.(1991) (778-778)

Cecilia L Amick↗

Curating NASA's Past, Present, and Future Extraterrestrial Sample Collections

As codified in NASA Policy Directive 7100.10F, the Astromaterials Acquisition and Curation Office at NASA Johnson Space Center (hereafter JSC Curation) is charged with curation of all extraterrestrial material under NASA control, including future NASA missions. JSC Curation curates all or part of nine astromaterial collections in seven clean room suites: (1) Apollo Samples (1969; ISO 6-7), (2) Luna Samples (from USSR; 1972; ISO 7), (3) Antarctic Meteorites (1976; ISO 7), (4) Cosmic Dust (1981; ISO 5), (5) Microparticle Impact Collection (formerly called Space Exposed Hardware; 1985; ISO 5), (6) Genesis Solar Wind Atoms (2004; ISO 4); (7) Stardust Comet Particles (2006; ISO 5), (8) Stardust Interstellar Particles (2006; ISO 5), (9) Hayabusa Asteroid Particles (from JAXA; 2010; ISO 5). In addition to the labs that house the samples, we have installed and maintained a wide variety of facilities and infrastructure required to support the clean-rooms: more than 10 different HEPA-filtered air-handling systems, ultrapure dry gaseous nitrogen systems, an ultrapure water system (UPW) and cleaning facilities to provide clean tools and equipment for the labs. We also have sample preparation facilities for making thin sections, microtome sections, and even focused ion-beam (FIB) sections to meet the research requirements of scientists. To ensure that we are keeping the samples as pristine as possible, we routinely monitor the cleanliness of our clean rooms and infrastructure systems. This monitoring includes: daily monitoring of the quality of our UPW, weekly airborne particle counts in the labs, monthly monitoring of the stable isotope composition of the gaseous N2 system, and annual measurements of inorganic or organic contamination in processing cabinets. We track within our databases the current and ever-changing characteristics of more than 250,000 individual samples across our various collections (including the 19,141 samples on loan to 433 Principal Investigators in 24 countries). The next sample return missions that NASA will participate in are Hayabusa2 and OSIRIS-REx (Origins Spectral Interpretation Resource Identification Security - Regolith Explorer). The designs for a new state-of-the-art suite of clean rooms to house these samples at JSC have been finalized. This includes separate ISO class 5 clean rooms to house each collection, a common ISO class 7 area for general use, an ISO class 7 microtome laboratory, and a separate thin section lab. Additionally, a new cleaning facility is being designed and procedures developed that will allow for enhanced cleaning of cabinets and tools in an inorganically, organically, and biologically clean manner. We are also designing a large multi-purpose Advanced Curation laboratory that will allow us to develop the techniques necessary to fully support the Hayabusa2 and OSIRIS-REx missions, as well as future possible sample return missions (e.g., Lunar Polar Volatiles, Mars, Comet Surface). A micro-CT (micro Computed Tomography) laboratory dedicated to the study of astromaterials has come online within JSC Curation, and we plan to add additional facilities that will enable non-destructive (or minimally-destructive) analyses of astromaterials in the near future (e.g., micro-XRF (micro X-Ray Fluorescence), confocal imaging Raman Spectroscopy). These facilities will be available to: (1) develop sample handling and storage techniques for future sample return missions, (2) be utilized by PET (Positron Emission Tomography) for future sample return missions, (3) for retroactive PET-style analyses of our existing collections, and (4) for periodic assessments of the existing sample collections.

Zeigler, Ryan A.↗