Engineering Papers⌕ Search

SEARCH · Engineering Papers

Results for “cavity optimization”

Search indexed NASA NTRS and DOE OSTI research on propulsion, heat transfer, battery materials and energy systems. Follow report and document links to the original sources.

Quote a phrase for an exact phrase match. Source license links do not imply unrestricted reuse.

At least 433 records · Page 24

BEAM OPTIMIZATION STUDY FOR AN X-RAY FEL OSCILLATOR AT THE LCLS-II

The 4 GeV LCLS-II superconducting linac with high repetition beam rate enables the possibility to drive an X-Ray FEL oscillator at harmonic frequencies *. Compared to the regular LCLS-II machine setup, the oscillator mode requires a much longer bunch length with a relatively lower current. Also a flat longitudinal phase space distribution is critical to maintain the FEL gain since the X-ray cavity has extremely narrow bandwidth. In this paper, we study the longitudinal phase space optimization including shaping the initial beam from the injector and optimizing the bunch compressor and dechirper parameters. We obtain a bunch with a flat energy chirp over 400 fs in the core part with current above 100 A. The optimization was based on LiTrack and Elegant simulations using LCLS-II beam parameters.

Qin, Weilun↗

Time-drift Aware RF Optimization with Machine Learning Techniques

The Fermilab Linac delivers 400 MeV H- beam to the rest of the accelerator chain. Providing stable intensity, energy, and emittance is key since it directly affects downstream machines. To operate high current beam, accelerators must minimize uncontrolled particle loss; this can be accomplished by minimizing beam longitudinal emittance via RF parameter optimization. However, RF tuning is required daily since the resonance frequency of the accelerating cavities is affected by ambient temperature and humidity variations and thus drifts with time. In addition, the energy and phase space distribution of particles emerging from the ion source are subject to fluctuations. Such drift is not unique to Fermilab, but rather affects most laboratories. We are exploring machine learning (ML) algorithms for automated RF tuning for 2 objectives: optimization of Linac output energy and phase oscillation correction, with an emphasis on time-drift aware modeling that can account for conditions changing over time.

43 PARTICLE ACCELERATORS↗

Test cavity and Iris-to-Coax transition for tuning and high-power verification of SNS DTL iris couplers

The Spallation Neutron Source (SNS) Drift Tube Linac (DTL) employs iris couplers to efficiently deliver RF power into the accelerating structure. To support the development, tuning, and high‑power conditioning of these couplers prior to installation in the actual DTLs, a dedicated test cavity and an iris‑to‑coaxial transition structure have been designed. This work presents the electromagnetic design, simulation, and optimization of the test setup, enabling precise characterization of the iris coupler’s performance. The transition structure allows for tuning of the iris opening dimensions without requiring a waveguide taper or full‑size waveguide transitions, while maintaining impedance matching between the coaxial feed and the iris geometry to minimize reflection and power loss. During low‑power tests, the iris opening di-mensions can be evaluated using the iris‑to‑coax transi-tion attached to the test cavity. For high‑power condi-tioning, full‑size waveguides with ceramic vacuum win-dows are connected to the test cavity to replicate opera-tional conditions. Key design parameters were optimized using computer-aided simulation, and sensitivity studies were conducted to assess the impact of mechanical toler-ances on RF performance. The resulting test platform provides a reliable and efficient means for tuning and validating iris couplers, contributing to improved opera-tional stability in the SNS DTL.

Lee, Sung-Woo [ORNL] (ORCID:000000030915835X)↗

Cavity Design, Fabrication and Commission Performance of a 750MHz, 4-rod Separator for CEBAF 4-Hall Beam Delivery System

A short version of the original CEBAF normal conducting 4-rod separator cavity has been developed into a 750MHz one * since the concept of simultaneous 4-hall operation for CEBAF is introduced **. This work has been advanced further based on the EM design optimization, bench measurement and by conducting RF-thermal coupled simulation using CST and ANSYS to confirm the cavity tuning and thermal performance. The cavity fabrication used matured technology like copper plating and machining. The cavity flanges, couplers, tuners and cooling channels adopted consistent/compatible hardware with the existing 500MHz cavities. The electromagnetic and thermal design simulations have greatly reduced the prototyping and bench tuning time of the first prototype. Four production cavities have reached a typical 1.94MV kick voltage or 3.0kW wall loss on each cavity after a minor multipactoring or no processing, 7.5% overhead power than the design specification.

Wang, Haipeng↗

Bayesian optimization of Fisher Information in nonlinear multiresonant quantum photonics gyroscopes

Abstract We propose an on-chip gyroscope based on nonlinear multiresonant optics in a thin film χ (2) resonator that combines high sensitivity, compact form factor, and low power consumption simultaneously. We theoretically analyze a novel holistic metric – Fisher Information capacity of a multiresonant nonlinear photonic cavity – to fully characterize the sensitivity of our gyroscope under fundamental quantum noise conditions. Leveraging Bayesian optimization techniques, we directly maximize the nonlinear multiresonant Fisher Information. Our holistic optimization approach orchestrates a harmonious convergence of multiple physical phenomena – including noise squeezing, nonlinear wave mixing, nonlinear critical coupling, and noninertial signals – all encapsulated within a single sensor-resonator, thereby significantly augmenting sensitivity. We show that ∼ 470 × $\sim 470{\times}$ improvement is possible over the shot-noise limited linear gyroscope with the same footprint, intrinsic quality factors, and power budget.

42 ENGINEERING↗

PHASE LAW OF A HIGH INTENSITY SUPERCONDUCTING LINAC

The importance of a proper phase law is recognized to tune the synchronous phase of each superconducting cavities of a high intensity proton superconducting linac such as the SNS linac. The factors to be optimized are 1) maximizing the longitudinal acceptance 2) better matching throughout the linac and 3) achieving maximum beam energy. The driving force behind this study is how to effectively control the large voltage fluctuation from cavity to cavity, achieving low beam loss and high beam quality.

43 PARTICLE ACCELERATORS↗

INVESTIGATION OF THE MULTILAYER SHIELDING EFFECT THROUGH NbTiN-AlN COATED BULK NIOBIUM

Superconducting radio frequency (SRF) cavities, composed of bulk niobium (Nb), are extensively utilized in particle accelerators. To optimize their performance and extend their operational range, thin films of superconducting materials are applied to the Nb surfaces. This study focuses on investigating the magnetic field penetration characteristics of NbTiN-AlN coating on bulk niobium. The experimental setup involves measuring the magnetic field penetration across flat superconducting samples at cryogenic temperatures. One key parameter of interest is the field just before the first flux penetration, Bp which enables the observation of the multilayer shielding effect on bulk niobium under high magnetic fields. The study reveals a significant enhancement in Bp of the NbTiN-AlN coated Nb samples compared to bare Nb samples. This property holds critical importance for achieving high field performance in SRF cavities. Furthermore, the study explores the relationship between coating thickness and Bp corroborating the theoretical predictions.

Senevirathne, I. H.↗

Evaluation of the diffusion coefficient of fluorine during the electropolishing of niobium

Future accelerators require unprecedented cavity performance, which is strongly influenced by interior surface nano-smoothness. Electropolishing (EP) is the technique of choice being developed for high–field SRF cavities. Previous study has shown that the mechanism of Nb electropolishing proceeds by formation and dissolution of a compact salt film under fluorine diffusion-limited mass transport control. We pursue an improved understanding of the microscopic conditions required for optimum surface finishing. The viscosity of the standard electrolyte has been measured using a commercial viscometer, and the diffusion coefficient of fluorine was derived at a variety of temperatures from 0ºC to 50ºC using an Nb rotating disk electrode. In addition, data indicate that electrode kinetics becomes competitive with the mass transfer current limitation and increases dramatically with temperature. These findings are expected to guide the optimization of EP process parameters for achieving controlled, reproducible and uniform nano-smooth surface finishing of SRF cavities.

43 PARTICLE ACCELERATORS↗

Impurity Content Optimization to Maximize Q-Factors of Superconducting Resonators

Quality factor of superconducting radio-frequency (SRF) cavities is degraded whenever magnetic flux is trapped in the cavity walls during the cooldown. In this contribution we study how the trapped flux sensitivity, defined as the trapped flux surface resistance normalized for the amount of trapped flux, depends on the mean free path. A systematic study of a variety of 1.3 GHz cavities with different surface treatments (EP, 120 C bake and different N-doping) is carried out. A bell shaped trend appears for the range of mean free path studied. Over-doped cavities fall at the maximum of this curve defining the largest values of sensitivity. In addition, we have studied the trend of the BCS surface resistance contribution as a function of mean free path, showing that N-doped cavities follow close to the theoretical minimum. Adding these results together we show that the 2/6 N-doping treatment gives the highest Q-factor values at 2 K and 16 MV/m, as long as the magnetic field fully trapped during the cavity cooldown is lower than 10 mG.

43 PARTICLE ACCELERATORS↗

Effect of Dosimetric Outliers on the Performance of a Commercial Knowledge-Based Planning Solution

Purpose: RapidPlan, a commercial knowledge-based planning solution, uses a model library containing the geometry and associated dosimetry of existing plans. This model predicts achievable dosimetry for prospective patients that can be used to guide plan optimization. However, it is unknown how suboptimal model plans (outliers) influence the predictions or resulting plans. We investigated the effect of, first, removing outliers from the model (cleaning it) and subsequently adding deliberate dosimetric outliers. Methods and Materials: Clinical plans from 70 head and neck cancer patients comprised the uncleaned (UC) Model{sub UC}, from which outliers were cleaned (C) to create Model{sub C}. The last 5 to 40 patients of Model{sub C} were replanned with no attempt to spare the salivary glands. These substantial dosimetric outliers were reintroduced to the model in increments of 5, creating Model{sub 5} to Model{sub 40} (Model{sub 5-40}). These models were used to create plans for a 10-patient evaluation group. Plans from Model{sub UC} and Model{sub C}, and Model{sub C} and Model{sub 5-40} were compared on the basis of boost (B) and elective (E) target volume homogeneity indexes (HI{sub B}/HI{sub E}) and mean doses to oral cavity, composite salivary glands (comp{sub sal}) and swallowing (comp{sub swal}) structures. Results: On average, outlier removal (Model{sub C} vs Model{sub UC}) had minimal effects on HI{sub B}/HI{sub E} (0%-0.4%) and sparing of organs at risk (mean dose difference to oral cavity and comp{sub sal}/comp{sub swal} were ≤0.4 Gy). Model{sub 5-10} marginally improved comp{sub sal} sparing, whereas adding a larger number of outliers (Model{sub 20-40}) led to deteriorations in comp{sub sal} up to 3.9 Gy, on average. These increases are modest compared to the 14.9 Gy dose increases in the added outlier plans, due to the placement of optimization objectives below the inferior boundary of the dose-volume histogram-predicted range. Conclusions: Overall, dosimetric outlier removal from or addition of 5 to 10 outliers to a 70-patient model had marginal effects on resulting plan quality. Although the addition of >20 outliers deteriorated plan quality, the effect was modest. In this study, RapidPlan demonstrated robustness for moderate proportions of salivary gland dosimetric outliers.

62 RADIOLOGY AND NUCLEAR MEDICINE↗

Extraction of depth-dependent perturbation factors for parallel-plate chambers in electron beams using a plastic scintillation detector

Purpose: This work presents the experimental extraction of the overall perturbation factor P{sub Q} in megavoltage electron beams for NACP-02 and Roos parallel-plate ionization chambers using a plastic scintillation detector (PSD). Methods: The authors used a single scanning PSD mounted on a high-precision scanning tank to measure depth-dose curves in 6, 12, and 18 MeV clinical electron beams. The authors also measured depth-dose curves using the NACP-02 and PTW Roos chambers. Results: The authors found that the perturbation factors for the NACP-02 and Roos chambers increased substantially with depth, especially for low-energy electron beams. The experimental results were in good agreement with the results of Monte Carlo simulations reported by other investigators. The authors also found that using an effective point of measurement (EPOM) placed inside the air cavity reduced the variation of perturbation factors with depth and that the optimal EPOM appears to be energy dependent. Conclusions: A PSD can be used to experimentally extract perturbation factors for ionization chambers. The dosimetry protocol recommendations indicating that the point of measurement be placed on the inside face of the front window appear to be incorrect for parallel-plate chambers and result in errors in the R{sub 50} of approximately 0.4 mm at 6 MeV, 1.0 mm at 12 MeV, and 1.2 mm at 18 MeV.

46 INSTRUMENTATION RELATED TO NUCLEAR SCIENCE AND ↗

Accelerator Physics at NSLS-II: Research Accomplishments in 2023

NSLS-II accelerator physicists provided operation support for user operations and machine start-ups, carried out routine lattice characterization, and produced regular reports on beam dynamics. The commissioning of a superconducting wiggler for the HEX beamline is complete, and the wiggler effects on beam dynamics have been studied. A Facility Improvement Project for absolute lattice characterization has been approved and funded. We implemented and tested a new orbit-based technique of lattice characterization and correction. We developed a theory to calculate the beam-induced power in ceramic vacuum chambers and a new convergence map technique for nonlinear lattice characterization. We continued working on the NSLS-II upgrade including lattice development, commissioning a low-energy complex bend prototype, analyzing beam sensitivity to various errors, implementing higher-harmonic RF cavities, studying collective effects, and assessing FEL options. We also supported lattice optimization and beam diagnostics development for the EIC project. Main research accomplishments achieved in 2023, are summarized in this report.

43 PARTICLE ACCELERATORS↗

Pipeline Monitoring Using Highly Sensitive Vibration Sensor Based on Fiber Ring Cavity Laser

A vibration fiber sensor based on a fiber ring cavity laser and an interferometer based single-mode-multimode-single-mode (SMS) fiber structure is proposed and experimentally demonstrated. The SMS fiber sensor is positioned within the laser cavity, where the ring laser lasing wavelength can be swept to an optimized wavelength using a simple fiber loop design. To obtain a better signal-to-noise ratio, the ring laser lasing wavelength is tuned to the maximum gain region biasing point of the SMS transmission spectrum. A wide range of vibration frequencies from 10 Hz to 400 kHz are experimentally demonstrated. In addition, the proposed highly sensitive vibration sensor system was deployed in a field-test scenario for pipeline acoustic emission monitoring. An SMS fiber sensor is mounted on an 18” diameter pipeline, and vibrations were induced at different locations using a piezoelectric transducer. The proposed method was shown to be capable of real-time pipeline vibration monitoring.

47 OTHER INSTRUMENTATION↗

Fast Beam-Based BPM Calibration

The Alignment Diagnostic System (ADS) of the LCLS undulator system indicates that the 33 undulator quadrupoles have extremely high position stability over many weeks. However, beam trajectory straightness and lasing efficiency degrade more quickly than this. A lengthy Beam Based Alignment (BBA) procedure must be executed every two to four weeks to re-optimize the X-ray beam parameters. The undulator system includes RF cavity Beam Position Monitors (RFBPMs), several of which are utilized by an automatic feedback system to align the incoming electron-beam trajectory to the undulator axis. The beam trajectory straightness degradation has been traced to electronic drifts of the gain and offset of the BPMs used in the beam feedback system. To quickly recover the trajectory straightness, we have developed a fast beam-based procedure to recalibrate the BPMs. This procedure takes advantage of the high-precision monitoring capability of the ADS, which allows highly repeatable positioning of undulator quadrupoles. This report describes the ADS, the position stability of the LCLS undulator quadrupoles, and some results of the new recovery procedure.

43 PARTICLE ACCELERATORS↗

Utilization of the CW magnetrons as coherent RF sources for superconducting RF accelerators

CW magnetrons designed and optimized for industrial heaters, driven by an injection-locking signal, were suggested to power Superconducting RF (SRF) cavities. However, the CW magnetrons, which are regenerative generators, are intended to operate in self-excitation mode, so, for reliable starting they use a large regenerative gain, causing a large regenerative instability in operation. Thus, power supply ripple, even shot noise, etc., lead to multiple sidebands forming a quasi-continuous noise spectrum at the carrier frequency. Therefore, in the traditionally used mode of operation and control, such magnetrons are inapplicable for powering high Q-factor SRF cavities. A new approach to operation and control of CW magnetrons considering non-stationary processes during start-up and operation makes it possible to find a mode of almost coherent RF generation of tubes with a significant reduction in regenerative instability and noise and increased efficiency. In our work is presented substantiation for the newly developed mode with an analysis of the new approach based on experimental results. •In this article, for the first time, non-stationary, regenerative processes are considered during the start-up and operation of CW magnetrons for powering high-Q superconducting RF cavities.•An analytical study, confirmed by experiments, showed that the traditionally used modes of starting and operating CW magnetrons are not suitable for powering high-Q superconducting RF cavities.•In fact, to make CW magnetrons suitable for such cavities, the physics of starting and operating CW magnetrons must be changed. This has been demonstrated in our work.•In developing the Stimulated Coherent Generation Mode [NIM A 980 (2020) 164366], we have shown the suitability of this mode for starting and operating CW magnetrons for high-Q superconducting RF cavities.•Analytical analysis, verified experimentally, substantiates in our article the suitability of the “Mode of stimulated coherent generation” of CW magnetrons for powering high-Q superconducting cavities in pulsed and continuous modes.

43 PARTICLE ACCELERATORS↗

Plasma Processing of Superconducting Radio Frequency Cavities

The development of plasma processing technology of superconducting radio frequency (SRF) cavities not only provides a chemical free and less expensive processing method, but also opens up the possibility for controlled modification of the inner surfaces of the cavity for better superconducting properties. The research was focused on the transition of plasma etching from two dimensional flat surfaces to inner surfaces of three dimensional (3D) structures. The results could be applicable to a variety of inner surfaces of 3D structures other than SRF cavities. Understanding the A r/C L plasma etching mechanism is crucial for achieving the desired modification of Nb SRF cavities. In the process of developing plasma etching technology, an apparatus was built and a method was developed to plasma etch a single cell Pill Box cavity. The plasma characterization was done with the help of optical emission spectroscopy. The Nb etch rate at various points of this cavity was measured before processing the SRF cavity. Cylindrical ring-type samples of Nb placed on the inner surface of the outer wall were used to measure the dependence of the process parameters on plasma etching. The measured etch rate dependence on the pressure, rf power, dc bias, temperature, CI2 concentration and diameter of the inner electrode was determined. The etch rate mechanism was studied by varying the temperature of the outer wall, the dc bias on the inner electrode and gas conditions. In a coaxial plasma reactor, uniform plasma etching along the cylindrical structure is a challenging task due to depletion of the active radicals along the gas flow direction. The dependence of etch rate uniformity along the cylindrical axis was determined as a function of process parameters. The formation of dc self-biases due to surface area asymmetry in this type of plasma and its variation on the pressure, rf power and gas composition was measured. Enhancing the surface area of the inner electrode to reduce the asymmetry was studied by changing the contour of the inner electrode. The optimized contour of the electrode based on these measurements was chosen for SRF cavity processing.

Upadhyay, Janardan↗

Design study of a transverse-to-longitudinal emittance exchange proof-of-principle experiment

Transverse-to-longitudinal emittance exchange can be achieved through certain arrangements of dipole magnets and a dipole mode rf cavity. Theory on such schemes has been developed in the past several years. In this paper we report our numerical simulations to optimize a low energy (E sime 15 MeV) proof-of-principle experiment planned at the Argonne Wakefield Accelerator (AWA). Parametric studies of the dipole magnets and cavity strengths, as well as initial beam parameters, are presented.

43 PARTICLE ACCELERATORS↗

SU-F-E-03: PET/CT Guided Dose Boost to Hypoxic Sub-Volume in Nasopharyngeal Carcinomas Using Self-Optimizing Non-Uniform VMAT

Purpose: This study is to evaluate the feasibility of simultaneously integrated boost (SIB) to hypoxic subvolume (HTV) in nasopharyngeal carcinomas under the guidance of 18F-Fluoromisonidazole (FMISO) PET/CT using a novel non-uniform volumetric modulated arc therapy (VMAT)technique. Methods: Eight nasopharyngeal carcinoma patients treated with conventional uniform VMAT were retrospectively analyzed. For each treatment, actual conventional uniform VMAT plan with two or more arcs (2–2.5 arcs, totally rotating angle < 1000o) was designed with dose boost to hopxic subvolume (total dose, 84Gy) in the gross tumor volme (GTV) under the guidance of 18F- FMISO PET/CT. Based on the same dataset, experimental single arc non-uniform VAMT plans were generated with the same dose prescription using customized software tools. Dosimetric parameters, quality assurance and the efficiency of the treatment delivery were compared between the uniform and non-uniform VMAT plans. Results: To develop the non-uniform VMAT technique, a specific optimization model was successfully established. Both techniques generate high-quality plans with pass rate (>98%) with the 3mm, 3% criterion. HTV received dose of 84.1±0.75Gy and 84.1±1.2Gy from uniform and non-uniform VMAT plans, respectively. In terms of target coverage and dose homogeneity, there was no significant statistical difference between actual and experimental plans for each case. However, for critical organs at risk (OAR), including the parotids, oral cavity and larynx, dosimetric difference was significant with better dose sparing form experimental plans. Regarding plan implementation efficiency, the average machine time was 3.5 minutes for the actual VMAT plans and 3.7 minutes for the experimental nonuniform VMAT plans (p>0.050). Conclusion: Compared to conventional VMAT technique, the proposed non-uniform VMAT technique has the potential to produce efficient and safe treatment plans, especially in cases with complicated anatomical structures and demanding dose boost to subvolumes.

60 APPLIED LIFE SCIENCES↗