Engineering Papers⌕ Search

SEARCH · Engineering Papers

Results for “cavities”

Search indexed NASA NTRS and DOE OSTI research on propulsion, heat transfer, battery materials and energy systems. Follow report and document links to the original sources.

Quote a phrase for an exact phrase match. Source license links do not imply unrestricted reuse.

At least 433 records · Page 24

Recent Progress of RF Cavity Study at Mucool Test Area

Summar of presentation is: (1) MTA is a multi task working space to investigate RF cavities for R&D of muon beam cooling channel - (a) Intense 400 MeV H{sup -} beam, (b) Handle hydrogen (flammable) gas, (c) 5 Tesla SC solenoid magnet, (d) He cryogenic/recycling system; (2) Pillbox cavity has been refurbished to search better RF material - Beryllium button test will be happened soon; (3) E x B effect has been tested in a box cavity - Under study (result seems not to be desirable); (4) 201 MHz RF cavity with SRF cavity treatment has been tested at low magnetic field - (a) Observed some B field effect on maximum field gradient and (b) Further study is needed (large bore SC magnet will be delivered end of 2011); and (5) HPRF cavity beam test has started - (a) No RF breakdown observed and (b) Design a new HPRF cavity to investigate more plasma loading effect.

43 PARTICLE ACCELERATORS↗

Higher Order Modes Damping Analysis for the SPX Deflecting Cavity Cyromodule

A single-cell superconducting deflecting cavity operating at 2.815 GHz has been proposed and designed for the Short Pulse X-ray (SPX) project for the Advanced Photon Source (APS) upgrade. A cryomodule of 4 such cavities will be needed to produce the required 2-MV deflecting voltage. Each deflecting cavity is equipped with one fundamental power coupler (FPC), one lower order mode (LOM) coupler, and two higher order mode (HOM) couplers to achieve the stringent damping requirements for the unwanted modes. The damping of the LOM/HOM below the beampipe cutoff has been analyzed in the single cavity geometry and shown to meet the design requirements. The HOM above the beampipe cutoff in the 4-cavity cyromodule, however, may result in cross coupling which may affect the HOM damping and potentially be trapped between the cavities which could produce RF heating to the beamline bellows. We have evaluated the HOM damping in the 4-cavity cryomodule using the parallel finite element EM code suite ACE3P developed at SLAC. We will present the results of the cryomodule analysis in this paper.

43 PARTICLE ACCELERATORS↗

Higher Order Modes Damping Analysis for the SPX Deflecting Cavity Cryomodule

A single-cell superconducting deflecting cavity operating at 2.812 GHz has been proposed and designed for the Short Pulse X-ray (SPX) project for the Advanced Photon Source upgrade. A cryomodule of 4 such cavities will be needed to produce the required 2-MV deflecting voltage. Each deflecting cavity is equipped with one fundamental power coupler (FPC), one lower order mode (LOM) coupler, and two higher order mode (HOM) couplers to achieve the stringent damping requirements for the unwanted modes. The damping of the HOM/LOM modes below the beampipe cutoff has been analyzed in the single cavity geometry and shown to meet the design requirements. The HOMs above beam pipe cutoff in the 4-cavity cyromodule, however, may result in cross coupling which may affect the HOM damping and potentially trapped modes between the cavities which could produce RF heating to the beamline bellows and even be detrimental to the beam. We have evaluated the HOM damping and trapped modes in the 4-cavity cryomodule using the parallel finite element EM code ACE3P developed at SLAC. We will present the results of the cryomodule analysis in this paper.

43 PARTICLE ACCELERATORS↗

Progress on a Cavity with Beryllium Walls for Muon Ionization Cooling Channel R&D.

The Muon Accelerator Program (MAP) collaboration is working to develop an ionization cooling channel for muon beams. An ionization cooling channel requires the operation of high-gradient, normal-conducting RF cavities in multi-Tesla solenoidal magnetic fields. However, experiments conducted at Fermilab?s MuCool Test Area (MTA) show that increasing the solenoidal field strength reduces the maximum achievable cavity gradient. This gradient limit is characterized by an RF breakdown process that has caused significant damage to copper cavity interiors. The damage may be caused by field-emitted electrons, focused by the solenoidal magnetic field onto small areas of the inner cavity surface. Local heating may then induce material fatigue and surface damage. Fabricating a cavity with beryllium walls would mitigate this damage due to beryllium?s low density, low thermal expansion, and high electrical and thermal conductivity. We address the design and fabrication of a pillbox RF cavity with beryllium walls, in order to evaluate the performance of high-gradient cavities in strong magnetic fields.

43 PARTICLE ACCELERATORS↗

RF breakdown of 805 MHz cavities in strong magnetic fields

Ionization cooling of intense muon beams requires the operation of high-gradient, normal-conducting RF structures in the presence of strong magnetic fields. We have measured the breakdown rate in several RF cavities operating at several frequencies. Cavities operating within solenoidal magnetic fields B > 0.25 T show an increased RF breakdown rate at lower gradients compared with similar operation when B = 0 T. Ultimately, this breakdown behavior limits the maximum safe operating gradient of the cavity. Beyond ionization cooling, this issue affects the design of photoinjectors and klystrons, among other applications. We have built an 805 MHz pillbox-type RF cavity to serve as an experimental testbed for this phenomenon. This cavity is designed to study the problem of RF breakdown in strong magnetic fields using various cavity materials and surface treatments, and with precise control over sources of systematic error. We present results from tests in which the cavity was run with all copper surfaces in a variety of magnetic fields.

43 PARTICLE ACCELERATORS↗

Quench Studies of Six High Temperature Nitrogen Doped 9 Cell Cavities for Use in the LCLS-II Baseline Prototype Cryomodule at Jefferson Laboratory

Jefferson Lab (JLab) processed six nine-cell cavities as part of a small-scale production for LCLS-II cavity processing development utilizing the promising nitrogen-doping process. Various nitrogen-doping recipes have been scrutinized to optimize process parameters with the aim to guarantee an unloaded quality factor (Q_0) of 2.7∙10 10 at an accelerating field (Eacc) of 16 MV/m at 2.0 K in the cryomodule. During the R&D phase the characteristic Q0 vs. Eacc performance curve of the cavities has been measured in JLab’s vertical test area at 2 K. The findings showed the characteristic rise of the Q0 with Eacc as expected from nitrogen-doping. Initially, five cavities achieved an average Q0 of 3.3·10 10 at the limiting Eacc averaging to 16.8 MV/m, while one cavity experienced an early quench accompanied by an unusual Q_0 vs. Eacc curve. The project accounts for a cavity performance loss from the vertical dewar test (with or without the helium vessel) to the horizontal performance in a cryomodule, such that these results leave no save margin to the cryomodule specification. Consequently, a refinement of the nitrogen-doping has been initiated to guarantee an average quench field above 20 MV/m without impeding the Q_0. This paper covers the refinement work performed for each cavity, which depends on the initial results, as well as a quench analysis carried out before and after the rework during the vertical RF tests as far as applicable.

43 PARTICLE ACCELERATORS↗

First Test Results of the bERLinPro 2-cell Booster Cavities

The bERLinPro Energy Recovery Linac (ERL) is currently being built at Helmholtz-Zentrum Berlin in order to study the physics of operating a high-current, a 100 mA, 50 MeV ERL utilizing all SRF cavity technology. This machine will utilize three unique SRF cryomodules for the photoinjector, booster and linac cryomodules respectively. The focus of this paper will be on the cavities contained within the booster cryomodule. Here there will be three 2-cell SRF cavities, based on the original design by Cornell University, but optimized to meet the needs of the project. All of the cavity fabrication, processing and testing was carried out at Jefferson Laboratory, where 4 cavities were produced, and the 3 cavities with the best RF performance were fitted with helium vessels for installation in the cryomodule. This paper will report on the test results of the cavities as measured in the vertical testing dewar at JLab after fabrication and again after outfitting with the helium vessels.

43 PARTICLE ACCELERATORS↗

Muon Capture, Phase Rotation, and Cooling in Pressurized RF Cavities

Gas-filled rf cavities can provide high-gradient accelerating fields for muons, and can be used for simultaneous acceleration and cooling of muons. In this paper we explore using these cavities in the front-end of the capture and cooling systems for neutrino factories and muon colliders. We consider using gas-filled rf cavities for the initial front end cooling systems. We also consider using them for simultaneous phase-energy rotation and cooling in a front-end system. We also consider using lower-density rf cavities, where the gas density is primarily for rf breakdown suppression, with less cooling effect. Pressurized rf cavities enable higher gradient rf within magnetic fields than is possible with evacuated cavities, enabling more options in the front-end. The status of designs of the capture, phase rotation, and precooling systems of muon beams in pressurized cavities is described.

43 PARTICLE ACCELERATORS↗

Superconducting RF Deflecting Cavity Design and Prototype for Short X-ray Pulse Generation

Deflecting RF cavities are proposed to be used in generating short x-ray pulses (on ~1-picosecond order) at the Advanced Photon Source (APS) at Argonne National Laboratory (ANL)* using a novel scheme by Zholents**. To meet the required deflecting voltage, impedance budget from higher order, lower order and the same order modes (HOM, LOM and SOM) of the APS storage ring, extensive deflecting cavity design studies have been conducted with numerical simulations and cavity prototypes. In this paper, we report recent progress on a single cell S-band (2.8-GHz) superconducting deflecting cavity design with waveguide damping. A copper and a niobium prototype cavity were fabricated and tested, respectively to benchmark the cavity and damping designs. A new damping scheme has been proposed which provides stronger damping to both HOM and LOM by directly coupling to a damping waveguide on the cavity equator.

43 PARTICLE ACCELERATORS↗

A clean pumping and venting system for SRF cavities and cryomodules.

A system based on a pair of mass flow controllers has been used to evacuate and vent a clean cavity rf space. The mass-flow system is used in both single cavity testing and with the ATLAS upgrade cryomodule at Argonne. It is similar schematically to that already in use at DESY, however, it is very compact and maintains the capability to precisely control both the pump out and venting rates. Initial tests of the system with both the ATLAS single cavity test cryostat and the ATLAS upgrade cryomodule show that pump down and venting cycles may be performed without introducing substantial particulates into the cavity rf space. The system, together with the ANL top loading cryomodule design with easy access to individual cavities, will allow an individual cavity to be removed and replaced in a cryomodule string without the need to re-clean the entire string. This capability would also remove the need to test every cavity individually before installation into the string, constituting a major savings for large projects.

75 CONDENSED MATTER PHYSICS, SUPERCONDUCTIVITY AND↗

A Hybrid Molecular–Nanophotonic Platform for On-Chip Cavity Quantum Electrodynamics and Collective Interactions

We present a hybrid solid-state cavity quantum electrodynamics (QED) platform that integrates a high density of coherent organic molecules with high-quality-factor nanophotonics. Thin anthracene crystals doped with dibenzoterrylene (DBT) are mechanically transferred onto prefabricated silicon nitride photonic crystal cavities, preserving both the cavity quality and molecular coherence. This approach decouples emitter synthesis from nanofabrication, providing a pathway for integrating other types of emitters. The high density of molecular emitters results in up to ten molecules being coupled to a single cavity. By tuning pairs of molecules into resonance within a single cavity mode, we observe cavity-mediated interactions in both dispersive and dissipative regimes. Furthermore, these results establish an accessible route to deterministic on-chip single- and multiphoton sources.

77 NANOSCIENCE AND NANOTECHNOLOGY↗

Quantum calculations of the cavity shift in electron magnetic moment measurements

The measurement of the anomalous electron magnetic moment g – 2 through quantum transitions of a single trapped electron is the most stringent test of quantum field theory. These experiments are now so precise that they must account for the effects of the cavity containing the electron. Classical calculations of this “cavity shift” must subtract the electron’s divergent self-field, and thus require knowledge of the exact Green’s function for the cavity’s electromagnetic field. We perform the first fully quantum calculation of the cavity shift in a closed cavity, which instead involves subtracting linearly divergent cavity mode sums and integrals. Using contour integration methods, we find perfect agreement with existing classical results for both spherical and cylindrical cavities, justifying their current use. Moreover, our mode-based results can be naturally generalized to account for systematic effects, necessary to push future measurements to the next order of magnitude in precision.

72 PHYSICS OF ELEMENTARY PARTICLES AND FIELDS↗

Cosmic Axion Background detection using resonant cavity arrays

The axion is a well-motivated and generic extension of the Standard Model. If produced in the early universe, axions may still be relativistic today, forming a Cosmic Axion Background (CaB) potentially detectable in direct detection experiments. Although CaB is expected to be broadband, which makes it challenging to be detected, a high-quality-factor microwave cavity acts as a narrowband filter with response peaked at its resonant frequency. We propose a new strategy using multi-cavity arrays to distinguish signal from background noise by exploiting spatial correlations of the axion-induced electric field which are set by the cavity quality factor. We compute the two-point correlation function for electric fields in spatially separated cavities sourced by an isotropic CaB. Analyzing various cavity geometries, we find that stacked, wide-base cavity arrays offer coherent enhancement of the axion signal. We apply our formalism to prospective upgrades of the ADMX experiment, including configurations with four and eighteen coupled cavities. Although these arrays do not achieve a coherent enhancement, optimizing the geometry could potentially yield an $\mathcal{O}(1)$ improvement in the sensitivity to the CaB.

Axions and ALPs↗

An analytical model for vertical dual-cavity quantum-dot optical amplifiers

Novel closed-form model for the threshold conditions and the optical gains of vertical dual-cavity semiconductor optical amplifier (VDC-SOA) is derived. Expressions for the transfer functions that relate the average photon density inside the two cavities to the incident photon density are derived. The model is simple, accurate and easy to use for designing dual-wavelength laser amplifiers. Good agreement is obtained between the analytical model and numerical calculations. The transmitted and reflective bistability characteristics of quantum dot VDC-SOA have been investigated. The threshold condition of each mode is expressed in terms of the top-cavity and the bottom-cavity currents. The dual modes λ{sub o}{sup +} and λ{sub o}{sup −} show different bistability behavior as a function of the top cavity current when the device operates at fixed operating point below the threshold curve. We find that the contrast ratio of mode λ{sub o}{sup +} is a weak function of the device currents, and the hysteresis width increases when the top cavity current is increased. For mode λ{sub o}{sup −} large contrast ratio and hysteresis width are obtained when the two cavities exhibit equal currents. Our analysis also reveals that the spectral characteristics of mode λ{sub o}{sup +} are different from that of mode λ{sub o}{sup −}.

71 CLASSICAL AND QUANTUM MECHANICS, GENERAL PHYSIC↗

Magnetic Resonance Image Guided Radiation Therapy for External Beam Accelerated Partial-Breast Irradiation: Evaluation of Delivered Dose and Intrafractional Cavity Motion

Purpose: To use magnetic resonance image guided radiation therapy (MR-IGRT) for accelerated partial-breast irradiation (APBI) to (1) determine intrafractional motion of the breast surgical cavity; and (2) assess delivered dose versus planned dose. Methods and Materials: Thirty women with breast cancer (stages 0-I) who underwent breast-conserving surgery were enrolled in a prospective registry evaluating APBI using a 0.35-T MR-IGRT system. Clinical target volume was defined as the surgical cavity plus a 1-cm margin (excluding chest wall, pectoral muscles, and 5 mm from skin). No additional margin was added for the planning target volume (PTV). A volumetric MR image was acquired before each fraction, and patients were set up to the surgical cavity as visualized on MR imaging. To determine the delivered dose for each fraction, the electron density map and contours from the computed tomography simulation were transferred to the pretreatment MR image via rigid registration. Intrafractional motion of the surgical cavity was determined by applying a tracking algorithm to the cavity contour as visualized on cine MR. Results: Median PTV volume was reduced by 52% when using no PTV margin compared with a 1-cm PTV margin used conventionally. The mean (± standard deviation) difference between planned and delivered dose to the PTV (V95) was 0.6% ± 0.1%. The mean cavity displacement in the anterior–posterior and superior–inferior directions was 0.6 ± 0.4 mm and 0.6 ± 0.3 mm, respectively. The mean margin required for at least 90% of the cavity to be contained by the margin for 90% of the time was 0.7 mm (5th-95th percentile: 0-2.7 mm). Conclusion: Minimal intrafractional motion was observed, and the mean difference between planned and delivered dose was less than 1%. Assessment of efficacy and cosmesis of this MR-guided APBI approach is under way.

62 RADIOLOGY AND NUCLEAR MEDICINE↗

Mechanical properties of niobium radio-frequency cavities

Radio-frequency cavities made of bulk niobium are one of the components used in modern particle accelerators. The mechanical stability is an important aspect of cavity design, which typically relies on finite-element analysis simulations using material properties from tensile tests on sample. This contribution presents the results of strain and resonant frequency measurements as a function of a uniform pressure up to 722 kPa, applied to single-cell niobium cavities with different crystallographic structure, purity and treatments. In addition, burst tests of high-purity multi-cell cavities with different crystallographic structure have been conducted up to the tensile strength of the material. Finite-element analysis of the single-cell cavity geometry is in good agreement with the observed behavior in the elastic regime assuming a Young's modulus value of 88.5 GPa and a Poisson's ratio of 0.4, regardless of crystallographic structure, purity or treatment. However, the measured yield strength and tensile strength depend on crystallographic structure, material purity and treatment. In particular, the results from this study show that the mechanical properties of niobium cavities with large crystals are comparable to those of cavities made of fine-grain niobium.

36 MATERIALS SCIENCE↗

Beam dynamics in independent phased cavities

Linear accelerators containing the sequence of independently phased cavities with constant geometrical velocity along each structure are widely used in practice. The chain of cavities with identical cell lengths is utilized within a certain beam velocity range, with subsequent transformation to the next chain with higher cavity velocity. Design and analysis of beam dynamics in this type of accelerator are usually performed using numerical simulations. A full theoretical description of particle acceleration in an array of independent phased cavities has not been developed. In the present paper, we provide an analytical treatment of beam dynamics in such linacs employing Hamiltonian formalism. We begin our analysis with an examination of beam dynamics in an equivalent traveling wave of a single cavity, propagating within accelerating section with constant phase velocity. We then consider beam dynamics in arrays of cavities, utilizing an effective traveling wave propagating along with the whole accelerator with the velocity of synchronous (reference) particle. The analysis concluded with the determination of the matched beam conditions. Finally, we present a beam dynamics study in 805 MHz Coupled Cavity Linac of the LANSCE accelerator facility.

46 INSTRUMENTATION RELATED TO NUCLEAR SCIENCE AND ↗

QM and QM/MM Studies of Uranyl Fluorides in the Gas and Aqueous Phases and in the Hydrophobic Cavities of Tetrabrachion

The structural properties and electronic structures of pentacoordinated uranyl complexes belonging to the [UO₂Fn(H₂O) 5-n ] 2-n series have been studied in the gas and aqueous phases using density functionals with relativistic pseudopotentials and all-electron basis sets in the gas-phase calculations in combination with COSMO in the aqueous phase. In addition, the conformational orientation and structural and electronic properties of [UO₂F₅]³¯ in the hydrophobic cavities of the right-handed coiled-coil (RHCC) protein of tetrabrachion have been determined using the hybrid QM/MM method. Although there is good agreement between the available experimental geometrical parameters and the values obtained in the aqueous phase using pseudopotentials or all-electron basis sets, variation of the uranyl U=O bond with the number of fluoride ligands is only truly captured after the inclusion of five water molecules in the second coordination sphere around the molecules. The docking procedure used in this work shows that there are only two possible orientations of the uranyl group of [UO₂F₅]³¯ embedded in the hydrophobic cavities of the RHCC protein. The two orientations are exclusively along the axes perpendicular to the protein axial channel with no possible orientation of the uranyl group along the axial channel because of both steric effects and interaction with the alkyl chain of the isoleucine residues pointing into the axial channel. In addition, the embedded complex is always positioned nearer to the isoleucine residues at the N-terminal ends of the hydrophobic cavities. Energy analysis, however, reveals that both conformations can only be observed in cavity 2, the largest hydrophobic cavity. The structural and electronic properties of the ligand embedded in this cavity are very similar to those of the gas-phase structure. A comparable study of [Pt(CN)₆]²¯ and the anticancer drug cisplatin, [PtCl₂(NH₃)₂], in cavity 2, revealed the existence of just two orientations for the former, similar to the uranyl complex, and multiple orientations for the latter.

37 INORGANIC, ORGANIC, PHYSICAL, AND ANALYTICAL CH↗