Engineering Papers⌕ Search

SEARCH · Engineering Papers

Results for “carbonate electrolytes”

Search indexed NASA NTRS and DOE OSTI research on propulsion, heat transfer, battery materials and energy systems. Follow report and document links to the original sources.

Quote a phrase for an exact phrase match. Source license links do not imply unrestricted reuse.

At least 433 records · Page 24

Oxygen‐Assisted Supercapacitive Swing Adsorption of Carbon Dioxide

Abstract We report on the supercapacitive swing adsorption (SSA) of carbon dioxide at different voltage windows in the presence of oxygen using activated carbon electrodes, and deliquescent, aqueous electrolytes. The presence of O 2 in the CO 2 /N 2 gas mixture results in an up to 11 times higher CO 2 adsorption capacity with 3 M MgBr 2 (at 0.6 V) and up to 4–5 times higher adsorption capacity with 3 M MgCl 2 (at 1 V). A tradeoff between high CO 2 adsorption capacities and lower coulombic efficiencies was observed at voltages above 0.6 V. The energetic and adsorptive performance of the electrodes in the presence of oxygen below 0.5 V was similar to the performance with a CO 2 /N 2 mixture without oxygen at 1 V. Cyclic voltammetry (CV) and electrochemical impedance spectroscopy (EIS) of the electrodes demonstrate that the specific capacitance increases while the diffusion resistance decreases in the presence of oxygen. Oxygen concentrations ranging between 5–20 % give similar energetic and adsorptive performance. The electrodes exhibit stable performance for up to 100 cycles of operation.

Bilal, Muhammad↗

Bridging interfacial properties and cell performance: A multiscale model for proton-exchange-membrane fuel cells

Here, to elucidate the impact of local interfaces on mass-transport resistance and overall cell performance of low-loaded proton-exchange-membrane fuel cells (PEMFCs), we present a multiscale modeling framework incorporating a novel modified agglomerate model. The model considers three distinct Pt-electrolyte interfaces: Pt on the carbon surface covered by either ionomer or water film and Pt inside carbon nanopores. Detailed mass-transport voltage-loss breakdowns reveal that coupled agglomerate-interface-scale mass transport dominates the mass-transport loss. The ionomer poisons the exterior-Pt surface through suppressing O 2 adsorption and intrinsic ORR activity, leading to low current-density performance. Conversely, interior-Pt interface enhances the kinetic performance but limits high current-density performance due to its low interfacial permeability. The exterior-Pt/water interface demonstrates superior kinetic performance and mass transport, though its practical implementation requires ensuring proton transport. By coupling the multiscale CL properties with ink parameters, the model identifies an optimal I to C ratio of approximately 0.5, a moderate value where the ionomer content is sufficient to guarantee proton transport without fully covering the Pt surface and forming large agglomeration, thus allowing the utilization of the Pt-water interface and avoiding high mass-transport loss. Overall, the model helps unravel limiting phenomena across different operating regimes and provides routes for optimizing performance.

Cell diagnostic↗

Selective Ligand Modification of Cobalt Porphyrins for Carbon Dioxide Electrolysis: Generation of a Renewable H2/CO Feedstock for Downstream Catalytic Hydrogenation

Catalytic hydrogenation is an attractive approach to produce green fuels and chemicals. The building blocks for these processes may be effectively produced from renewable power via direct electrochemical reduction of carbon dioxide in an aqueous media. For the first time, the impact of increasing the local proton concentration of cobalt porphyrin was examined by synthesizing new cobalt porphyrins 2, Co(o-OCH3)TPP and cobalt porphyrin 3, Co(o-OH)TPP. Cobalt porphyrins coated on carbon paper converted carbon dioxide and water into a mixture of hydrogen and carbon monoxide in an aqueous electrolyte at near neutral pH. Increasing the local proton availability of the commercial cobalt porphyrin 1, accelerates hydrogen generation under heterogeneous conditions across the range of potentials tested (-0.85 to -1.5 V vs. Ag/AgCl) and demonstrates high Faradaic efficiencies (ca. 90%) at low over-potentials (ca. 540 mV). The culmination of this work can help identify key parameters that facilitate generation of sustainable reagents for catalytic hydrogenation under practical and scalable conditions.

BIOMASS FUELS,INORGANIC, ORGANIC, PHYSICAL, AND AN↗

Fe-Coated Optical Fiber for Distributed Corrosion Monitoring in Soil and Aqueous Environment

Natural gas pipeline corrosion represents a substantial cost and safety concern during normal operations. The effective and real-time monitoring of corrosion is important to detect and mitigate pipeline risks before corrosion-related catastrophic events happen. Here, we describe the use of iron (Fe) coated optical fiber sensors (OFS) for distributed corrosion monitoring where Fe acts as a corrosion proxy. By using an optical backscattering reflectometer (OBR), corrosion was monitored based on the increase in the backscattered intensity amplitude of the light being passed as Fe underwent corrosion. The Fe-coated OFSs were prepared with a film thickness between 25–225 nanometers (nm) by an electroless plating approach and corroded by a carbon dioxide (CO2)-saturated acidic electrolyte. The corrosion rate (CR) was approximately 2.5 millimeters (mm)/year for Fe with a film thickness of 30 nm and increased with film thickness. Backscattering-based CRs were supported by visible light transmission measurements, which have been previously demonstrated. Additionally, a correlation between the intermittent transmission and residual Fe film thickness during the corrosion of Fe was established. The corrosion sensor was also tested in soil at > 1 foot depth. Fe-coated OFS was loaded into a Draka cable, which provides mechanical support during fiber deployment and installation into either acidified soil, top-soil, or sandy soil (50/50).

corrosion↗

Fe-Coated Optical Fiber for Distributed Corrosion Monitoring in Soil and Aqueous Environments

Natural gas pipeline corrosion represents a substantial cost and safety concern during normal operations. The effective and real-time monitoring of corrosion is important to detect and mitigate pipeline risks before corrosion-related catastrophic events happen. Here, we describe the use of iron (Fe) coated optical fiber sensors (OFS) for distributed corrosion monitoring where Fe acts as a corrosion proxy. By using an optical backscattering reflectometer (OBR), corrosion was monitored based on the increase in the backscattered intensity amplitude of the light being passed as Fe underwent corrosion. The Fe-coated OFSs were prepared with a film thickness between 25–225 nanometers (nm) by an electroless plating approach and corroded by a carbon dioxide (CO2)-saturated acidic electrolyte. The corrosion rate (CR) was approximately 2.5 millimeters (mm)/year for Fe with a film thickness of 30 nm and increased with film thickness. Backscattering-based CRs were supported by visible light transmission measurements, which have been previously demonstrated. Additionally, a correlation between the intermittent transmission and residual Fe film thickness during the corrosion of Fe was established. The corrosion was measurable out to > 100 meters (m), which is a significant improvement over our previous work, which showed corrosion sensing at < 10 m. The corrosion sensor was also tested in soil at > 1 foot depth.

corrosion↗

The kinetics of the O2/CO2 reaction in molten carbonate - Reaction orders for O2 and CO2 on NiO

The kinetics of the O2/CO2 reaction in molten carbonate is investigated using paste electrolytes and nickel sinter electrodes. A two-step approach to the determination of reaction orders is employed. First, exchange currents at various P(CO2) and P(O2) were measured using the low polarization method. Second, alpha(+) and alpha(-) values were obtained from the slope of the Allen-Hickling plot for current densities low enough so that concentration polarization within the electrode can be neglected. The reaction orders are + 1/4 in CO2 and + 5/8 in O2 in the cathodic direction, and - 3/4 in CO2 and + 1/8 in O2 in the anodic direction.

Winnick, J.↗

Survey on aging on electrodes and electrocatalysts in phosphoric acid fuel cells

The processes which contribute to the decay in performance of electrodes used in phosphoric acid fuel cell systems are discussed. Loss of catalytic surface area, corrosion of the carbon support, electrode structure degradation, electrolyte degradation, and impurities in the reactant streams are identified as the major areas for concern.

Stonehart, P.↗

Extraterrestrial materials processing and related transport phenomena

Several concepts for significant cost reductions in extraterrestrial resource utilization are described. After an introduction of the desirability of in situ resource utilization, several candidate chemical processes are mentioned. It is brought out that many of the key processes require fluid dynamics and heat transfer processes under reduced- and microgravity. These aspects are discussed within the broad framework of a two-phase thermal control systems. Another important aspect of space processing is that reliability and self-repairability are mandatory; automation aspects are discussed. In addition to these general considerations, the paper includes several specific processes that vary from solid electrolytic production of oxygen from carbon dioxide, to plasma-augmented reactions for reducing ilmenite on the moon.

Ramohalli, K. N. R.↗

Fe-Coated Optical Fiber for Distributed Corrosion Monitoring in Soil and Aqueous Environments

Natural gas pipeline corrosion represents a substantial cost and safety concern during normal operations. The effective and real-time monitoring of corrosion is important to detect and mitigate pipeline risks before corrosion-related catastrophic events happen. Here, we describe the use of iron (Fe) coated optical fiber sensors (OFS) for distributed corrosion monitoring where Fe acts as a corrosion proxy. By using an optical backscattering reflectometer (OBR), corrosion was monitored based on the increase in the backscattered intensity amplitude of the light being passed as Fe underwent corrosion. The Fe-coated OFSs were prepared with a film thickness between 25–225 nanometers (nm) by an electroless plating approach and corroded by a carbon dioxide (CO2)-saturated acidic electrolyte. The corrosion rate (CR) was approximately 2.5 millimeters (mm)/year for Fe with a film thickness of 30 nm and increased with film thickness. Backscattering-based CRs were supported by visible light transmission measurements, which have been previously demonstrated. Additionally, a correlation between the intermittent transmission and residual Fe film thickness during the corrosion of Fe was established. The corrosion was measurable out to > 100 meters (m), which is a significant improvement over our previous work, which showed corrosion sensing at < 10 m. The corrosion sensor was also tested in soil at > 1 foot depth.

aqueous environment↗

Electrolytes with Improved Safety Developed for High Specific Energy Li-Ion Cells with Si-Based Anodes

A number of electrolyte formulations that have improved safety characteristics have been developed for use with high capacity silicon-based anodes. To improve the compatibility with Si-based anodes, a number of technical approaches have been employed, including: (1) the use of mono-fluoroethylene carbonate (FEC) in conjunction with, or in lieu of, ethylene carbonate (EC), (2) the use of high proportions of fluorinated co-solvents, (3) the use of vinylene carbonate (VC) to stabilize the Si/C electrode, and (4) the use of lithium bis(oxalato)borate (LiBOB) to improve the compatibility of the electrolyte when Si/C electrodes are used in conjunction with high voltage cathodes. Candidate electrolytes were studied in Li/Si-C and Si-C/ Li(MnNiCo)O2 (NMC) coin cells, as well as in larger Si-C/NMC three-electrode cells equipped with lithium reference electrodes. In summary, many electrolytes that contain triphenyl phosphate (TPP), which is used as a flame retardant additive up to concentrations of 15 volume percent, and possess FEC as a co-solvent have been demonstrated to outperform the all-carbonate baseline electrolytes when evaluated in Si-C/ Li(MnNiCo)O2 cells.

Silicon-Based Anode↗

Research on oxygen recovery systems for use in space capsules

An improved electrochemical process was investigated for the recovery of oxygen from the atmospheres of manned space capsules. The objective of the proposed system is to recover the oxygen from CO2 with high efficiency and to recover the additional amount of oxygen from water that is required to provide a total oxygen makeup stream of about 2.0 lb/man-day. The carbon from the CO2 must be converted into a readily disposable or usable form. The results are given of initial experiments with a porous stainless steel cathode in a LiCl-KCl electrolyte with small additions of oxide, carbonate, and hydroxide.

Selman, J. R.↗

Quantifying SEI Reaction Rate in the Presence and Absence of Mn 2+

In this work, a methodology utilizing potentiostatic holds is developed for measuring side-reaction rates at graphite (Gr) electrodes. The influence of Mn 2+ on parasitic reactions is evaluated in the presence of various preformed solid-electrolyte interphases (SEI). Gr SEI preformation was carried out using vinylene carbonate (VC) or lithium difluoro(oxalato)borate (LiDFOB) as an additive. In addition, a highly fluorinated electrolyte, free of traditional non-fluorinated organic carbonates, was used. Parasitic current increases were observed for all preformed Gr SEIs when Mn 2+ was present. Of the preforming electrolytes, the VC-derived SEI showed the lowest parasitic currents both with and without Mn 2+ .

Tornheim, Adam [Argonne National Laboratory (ANL),↗

High Throughput Electrochemical Screening of Phosphate-Rich Nonflammable Electrolytes in Lithium-Ion Batteries

Frequent fires and explosions in lithium-ion batteries (LIBs) used in grid energy storage systems (ESS) highlight the necessity of revisiting nonflammable phosphate electrolytes as alternatives to the currently used flammable carbonates. However, previous studies have shown the difficulty of integrating phosphate solvents into LIB electrolytes due to compatibility issues with graphite. In this work, we developed a high-throughput (HTP) electrochemical characterization method, akin to pH test paper, to rapidly screen potential phosphate electrolytes and graphite materials. Through HTP screening, we identified 101 promising combinations out of 1,740. This number was reduced to 26 after testing in Li/Graphite half cells. The optimized phosphate-rich electrolyte (60 v% phosphate) with cosolvents demonstrated 300 stable cycles at 0.1 C in Graphite/LiFePO 4 (LFP) full cells with thick electrodes (∼3.0 mAh cm −2 ), surpassing prior research findings. This unique HTP method provides a powerful tool to expedite the development of safe LIBs for ESS applications.

25 ENERGY STORAGE↗

Study of Stable Cathodes and Electrolytes for High Specific Density Lithium-Air Battery

Future NASA missions require high specific energy battery technologies, greater than 400 Wh/kg. Current NASA missions are using "state-of-the-art" (SOA) Li-ion batteries (LIB), which consist of a metal oxide cathode, a graphite anode and an organic electrolyte. NASA Glenn Research Center is currently studying the physical and electrochemical properties of the anode-electrolyte interface for ionic liquid based Li-air batteries. The voltage-time profiles for Pyr13FSI and Pyr14TFSI ionic liquids electrolytes studies on symmetric cells show low over-potentials and no dendritic lithium morphology. Cyclic voltammetry measurements indicate that these ionic liquids have a wide electrochemical window. As a continuation of this work, sp2 carbon cathode and these low flammability electrolytes were paired and the physical and electrochemical properties were studied in a Li-air battery system under an oxygen environment.

cathodes↗

Carbon Dioxide Gas Sensors and Method of Manufacturing and Using Same

A gas sensor comprises a substrate layer; a pair of interdigitated metal electrodes, said electrodes include upper surfaces, the electrodes selected from the group consisting of Pt, Pd, Au, Ir, Ag, Ru, Rh, In, Os, and their alloys. A first layer of solid electrolyte staying in between electrode fingers and partially on said upper surfaces of said electrodes, said first layer selected from NASICON, LISICON, KSICON and.beta.''-Alumina. A second layer of metal carbonate(s) as an auxiliary electrolyte engaging said upper surfaces of the electrodes and the first solid electrolyte. The metal carbonates selected from the group consisting of the following ions Na.sup.+, K.sup.+, Li.sup.+, Ag.sup.+, H.sup.+, Pb.sup.2+, Sr.sup.2+, Ba.sup.2+, and any combination thereof. An extra layer of metal oxide selected from the group consisting of SnO.sub.2, In.sub.2O.sub.3, TiO.sub.2, WO.sub.3, ZnO, Fe.sub.2O.sub.3, ITO, CdO, U.sub.3O.sub.8, Ta.sub.2O.sub.5, BaO, MoO.sub.2, MoO.sub.3, V.sub.2O.sub.5, Nb.sub.2O.sub.5, CuO, Cr.sub.2O.sub.3, La.sub.2O.sub.3, RuO.sub.3, RuO.sub.2, ReO.sub.2, ReO.sub.3, Ag.sub.2O, CoO, Cu.sub.2O, SnO, NiO, Pr.sub.2O.sub.3, BaO, PdO.sub.2, HfO.sub.3, HfO.sub.3 or other metal oxide and their mixtures residing above and in engagement with the second electrolyte to improve sensor performance and/or to reduce sensor heating power consumption.

Hunter, Gary W.↗

Ambient Rare Earth Metal Electrodeposition in Nitrogen-Coordinated Silylamide Electrolyte

The transition to a sustainable, low-carbon economy demands energy-efficient and environmentally benign methods for rare earth metal (REM) production. Furthermore, while high-temperature molten salt electrolysis remains energy-intensive, corrosive, and environmentally unfriendly, emerging room-temperature processes based on conventional ionic liquids are also hindered by high viscosity and chemical instability. In this study, a nitrogen-coordinated, water-, oxygen-, and fluorine-free silylamide-based electrolyte is presented as a promising system for room-temperature REM electrodeposition. Derived from commercially available lithium silylamide precursors, the system enables facile synthesis, broad electrochemical stability, and tunable metal–ligand interactions. Electrochemical analysis reveals high voltammetric stripping reversibility, stable cathodic and anodic potentials, and selective neodymium (Nd) deposition at appreciable current densities (>1 mA/cm 2 ), with minimal parasitic reactions. Bulk experiments produced high-purity Nd with reproducible performance across multiple batches. Scaled deposition yielded over 1 g of Nd with near-theoretical mass efficiency (0.40 mg/C) and >90% purity. Using sacrificial dysprosium (Dy) and Nd metal anodes, the system maintained constant Nd loading during extended deposition and enabled cathodic codeposition of stripped anode material, demonstrating the electrolyte’s dual functionality for REM electrorefining. Collectively, this silylamide platform offers a compelling combination of electrochemical robustness, chemical resilience, and process scalability for sustainable ambient REM recovery.

36 - MATERIALS SCIENCE↗