Engineering Papers⌕ Search

SEARCH · Engineering Papers

Results for “carbon dioxide concentration”

Search indexed NASA NTRS and DOE OSTI research on propulsion, heat transfer, battery materials and energy systems. Follow report and document links to the original sources.

Quote a phrase for an exact phrase match. Source license links do not imply unrestricted reuse.

At least 433 records · Page 24

Lightweight Fiber Optic Gas Sensor for Monitoring Regenerative Food Production

In this final report, Physical Optics Corporation (POC) describes its development of sensors for oxygen, carbon dioxide, and relative humidity. POC has constructed a phase fluorometer that can detect oxygen over the full concentration range from 0 percent to 100 percent. Phase-based measurements offer distinct advantages, such as immunity to source fluctuation, photobleaching, and leaching. All optics, optoelectronics, power supply, and the printed circuit board are included in a single box; the only external connections to the fluorometer are the optical fiber sensor and a power cord. The indicator-based carbon dioxide sensor is also suitable for short-term and discrete measurements over the concentration range from 0 percent to 100 percent. The optical fiber-based humidity sensor contains a porous core for direct interaction of the light beam with water vapor within fiber pores; the detection range for the humidity sensor is 10 percent to 100 percent, and response time is under five minutes. POC is currently pursuing the commercialization of these oxygen and carbon dioxide sensors for environmental applications.

Schmidlin, Edward↗

Comparing the Use of High- to Low-Cost Black Carbon and Carbon Dioxide Sensors for Characterizing On-Road Diesel Truck Emissions

The exhaust plume capture method is a commonly used approach to measure pollutants emitted by in-use heavy-duty diesel trucks. Lower cost sensors, if used in place of traditional research-grade analyzers, could enable wider application of this method, including use as a monitoring tool to identify high-emitting trucks that may warrant inspection and maintenance. However, low-cost sensors have for the most part only been evaluated under ambient conditions as opposed to source-influenced environments with rapidly changing pollutant concentrations. This study compared black carbon (BC) emission factors determined using different BC and carbon dioxide (CO 2 ) sensors that range in cost from $200 to $20,000. Controlled laboratory experiments show that traditional zero and span steady-state calibration checks are not robust indicators of sensor performance when sampling short duration concentration peaks. Fleet BC emission factor distributions measured at two locations at the Port of Oakland in California with 16 BC/CO 2 sensor pairs were similar, but unique sensor pairs identified different high-emitting trucks. At one location, the low-cost PP Systems SBA-5 agreed on the classification of 90% of the high emitters identified by the LI-COR LI-7000 when both were paired with the Magee Scientific AE33. Conversely, lower cost BC sensors when paired with the LI-7000 misclassified more than 50% of high emitters when compared to the AE33/LI-7000. Confidence in emission factor quantification and high-emitter identification improves with larger integrated peak areas of CO 2 and especially BC. This work highlights that sensor evaluation should be conducted under application-specific conditions, whether that be for ambient air monitoring or source characterization.

47 OTHER INSTRUMENTATION↗

Investigation of Martian H2O and CO2 via gamma-ray spectroscopy

The evolution and present state of water and carbon dioxide on Mars are discussed. Researchers wished to determine how effectively questions regarding the distribution of water and carbon dioxide on Mars may be addressed with orbital gamma ray spectrometer data. Several simple, multi-layer models of the Martian surface were formulated to address problems such as the ice/dust ratio of layered deposits; the distribution, depth and concentration of ground ice; the thickness of north polar perennial ice; the thickness of the carbon dioxide layer over the south polar cap; the thickness of the seasonal carbon dioxide frost cap; and the water content of the seasonal frost cap. The results indicate that the Mars Observer gamma ray spectrometer will be a powerful tool for investigating the distribution and stratigraphy of volatiles on Mars.

Squyres, Steven W.↗

Photocatalytic post-treatment in waste water reclamation systems

A photocatalytic water purification process is described which effectively oxidizes organic impurities common to reclaimed waste waters and humidity condensates to carbon dioxide at ambient temperatures. With this process, total organic carbon concentrations below 500 ppb are readily achieved. The temperature dependence of the process is well described by the Arrhenius equation and an activation energy barrier of 3.5 Kcal/mole. The posttreatment approach for waste water reclamation described here shows potential for integration with closed-loop life support systems.

Cooper, Gerald↗

Photochemistry of biogenic gases

The relationship between the biosphere and the atmosphere is examined, emphasizing the composition and photochemistry and chemistry of the troposphere and stratosphere. The reactions of oxygen, ozone, and hydroxyl are reviewed and the fate of the biogenic gases ammonia, methane, reduced sulfur species, reduced halogen species, carbon monoxide, nitric oxide, nitrous oxide, nitrogen, and carbon dioxide are described. A list is given of the concentration and sources of the various gases.

Levine, Joel S.↗

Carbon dioxide effects on potato growth under different photoperiods and irradiance

The effects of atmospheric CO2 concentration, photosynthetic photon flux (PPF), and the length of the photoperiod on the tuber yield were investigated for three potato cultivars (Norland, Russet Burbank, and Denali), by growing these cultivars for 90 days in atmospheres containing 350 or 1000 micromol/mol CO2, at photoperiods of 12- or 24-hr, and at PPFs of 400 or 800 micromol/sq m per sec. Air temperatures and relative humidity were kept at 16 C and 70 percent, respectively. It was found that the tuber yield of Denali potatoes showed the greatest increase (21 percent) in response to increased CO2 across all irradiance treatments, while the tuber yields of Russet and Norland were increased 18 and 9 percent, respectively. Greater plant growth from CO2 enrichment was observed under lower PPF and the shorter (12 hr) photoperiod.

Wheeler, Raymond M.↗

Optimization of A 2-Micron Laser Frequency Stabilization System for a Double-Pulse CO2 Differential Absorption Lidar

A carbon dioxide (CO2) Differential Absorption Lidar (DIAL) for accurate CO2 concentration measurement requires a frequency locking system to achieve high frequency locking precision and stability. We describe the frequency locking system utilizing Frequency Modulation (FM), Phase Sensitive Detection (PSD), and Proportional Integration Derivative (PID) feedback servo loop, and report the optimization of the sensitivity of the system for the feed back loop based on the characteristics of a variable path-length CO2 gas cell. The CO2 gas cell is characterized with HITRAN database (2004). The method can be applied for any other frequency locking systems referring to gas absorption line.

Chen, Songsheng↗

US Navy Submarine Sea Trial of NASA developed Multi-Gas Monitor

During a successful 2 year technology demonstration of the tunable diode laser spectroscopy (TDLS) based Multi-Gas Monitor (MGM) on the International Space Station (ISS), we began discussing with the US Navy the possibility of conducting a sea trial of an MGM on a submarine. The sea trial would also include a gas chromatography/differential mobility spectrometer based Air Quality Monitor (AQM), which is used operationally on ISS for select volatile organic compounds. AQM results will be the subject of a separate paper. The Navy’s interest in testing NASA equipment is in a planned update to the environmental monitoring equipment used aboard submarines. NASA’s goal is studying submarines as closed environment analogs to spacecraft. MGM’s core technology was developed by Vista Photonics Inc using Small Business Innovation Research (SBIR) grants and expanded for various applications using NASA program funding. The MGM measures oxygen, carbon dioxide, ammonia and water vapor in ambient air, displays concentrations with temperature and pressure, and stores 30 second moving averages. The sea trial involves colocating the instrument with the Central Air Monitor (CAM) and connecting it to rack power prior to departure, and letting it run during the entire sea trial of a few months duration. All data stored is inside MGM, with no connection to the vessel data bus. Crew intervention is limited to checking MGM periodically to see that it is working and power cycling if the display is OFF. After the trial is over, the unit with its data will be retrieved. Post sea trial calibration check and data analysis are planned and results will be compared with both CAM data and results from MGM’s ISS technology demonstration.

Mudgett, Paul D.↗

US Navy Submarine Sea Trial of NASA developed Multi-Gas Monitor

During a successful 2 year technology demonstration of the tunable diode laser spectroscopy (TDLS) based Multi-Gas Monitor (MGM) on the International Space Station (ISS), we began discussing with the US Navy the possibility of conducting a sea trial of an MGM on a submarine. The sea trial would also include a gas chromatography/differential mobility spectrometer based Air Quality Monitor (AQM), which is used operationally on ISS for volatile organic compound analysis. AQM preparation and results will be the subject of a separate paper. The Navy's interest in testing NASA equipment in general relates to their ongoing search for better air monitoring technology. NASA's goal is studying submarines as closed environment analogs to spacecraft. MGM's core technology was developed by Vista Photonics Inc. using Small Business Innovation Research (SBIR) grants and expanded for various applications using NASA program funding. The MGM measures oxygen, carbon dioxide, ammonia and water vapor in ambient air, displays concentrations with temperature and pressure, and stores 30 second moving averages. The sea trial involves collocating the instrument with the Central Atmosphere Monitoring System (CAMS Mk II) of the submarine, connecting it to rack power prior to departure, and letting it run during the entire 90 day patrol. All data is stored within MGM, with no connection to the vessel data bus. Crew intervention is limited to checking MGM periodically to see that it is working and power cycling if necessary. After the trial is over, the unit with its data will be retrieved. Post sea trial calibration check and data analysis are planned and results will be compared with both CAMS Mk II data and results from MGM's ISS technology demonstration. Since the sea trial itself has been delayed, this paper describes the preparation of MGM for the sea trial and also provides a summary of the latest data from the ISS MGM technology demonstration.

Mudgett, Paul D.↗

Facile, low-energy routes for the production of hydrated calcium and magnesium salts from alkaline industrial wastes

Divalent ions are extracted from solids by leaching to form a divalent ion-containing solution. The divalent ion-containing solution is subjected to concentration to form a concentrated divalent ion-containing solution. Precipitation of a divalent ion hydroxide salt is induced from the concentrated divalent ion-containing solution. In other cases, the concentrated divalent ion-containing solution is exposed to carbon dioxide to induce precipitation of a divalent ion carbonate salt.

Sant, Gaurav N.↗

Heat Transfer Characteristics of Particle and Air Flow Through Additively Manufactured Lattice Frame Material Based on Octet-Shape Topology

Particle-to-supercritical carbon dioxide (sCO 2 ) heat exchanger is a critical component in next-generation concentrating solar power (CSP) plants. The inherently low heat transfer between falling particles and sCO 2 imposes a challenge toward economic justification of levelized cost of electricity produced through solar energy. Introduction of integrated porous media with the walls bounding particle flow has the potential to enhance the overall particle-to-sCO 2 heat exchanger performance. Here, this paper presents an experimental study on heat transfer characterization of additively manufactured lattice frame material based on Octet-shaped unit cell with particles and air as working fluids. The lattice structures were additively manufactured in stainless steel (SS) 316L and SS420 (with 40% bronze infiltration) via Binder jetting process, where the lattice porosities were varied between 0.75 and 0.9. The mean particle diameters were varied from 266 μm to 966 μm. The effective thermal conductivity and averaged heat transfer coefficient were determined through steady-state experiments. It was found that the presence of lattice enhances the effective thermal conductivity by 2–4 times when compared to packed bed of particles alone. Furthermore, for gravity-assisted particle flow through lattice panel, significantly high convective heat transfer coefficients ranging from 200 W/m2K to 400 W/m2K were obtained for the range of particle diameters tested. The superior thermal transport properties of Octet-shape-based lattice frame for particle flow makes it a very promising candidate for particle-to-sCO 2 heat exchanger for CSP application.

14 SOLAR ENERGY↗

Increasing CO2 Conversion Efficiency with Optical Thermal Management in Concentrated Solar Reactors: New Dual-Stage Solar Reactor Design for Reduction of CO2 to Fuels

The proposed project will result in a new dual-stage solar chemical reactor designed to convert carbon dioxide (CO2) to value-added chemicals. Using sunlight as the main power source, a sustainable process will be developed that closes the loop on our industrial carbon cycle in an energy efficient and environmentally friendly manner. The hybrid photochemical and photothermal reactor design will vastly increase utilization of the solar spectrum and increase CO2 conversion efficiencies over Dimensional Energy’s current state-of-the-art.

10 SYNTHETIC FUELS↗

Effect of CO 2 Concentration on the Microbial Activity of Orenia metallireducens (Strain Z6) in Surface Inert Materials

Carbon dioxide (CO 2 ) sequestration has garnered widespread attention as a key strategy for mitigating CO 2 emissions and combating the greenhouse effect. However, the mechanisms underlying the interactions between CO 2 , widespread siliceous minerals and biological processes remain unclear. The present study explored the potential impacts of different CO 2 concentrations on microbial activity, environmental conditions and their feedback on the fate of CO 2 . A total of 20 experimental conditions was created, with the variables including different natural and synthetic siliceous minerals (e.g., quartz sand and a type of commercial glass beads), the presence or absence of the iron-reducing microorganism Orenia metallireducens (strain Z6) and varying CO 2 concentrations (0%, 20%, 50%, 100%) in the presence of ferrihydrite and pyruvate. Geochemical, microbial and mineralogical analyses revealed that elevated CO 2 concentrations significantly inhibited microbial Fe(III) reduction and pyruvate metabolism. Interestingly, compared to cultures without mineral amendments or those with glass beads alone, the addition of quartz sand enabled strain Z6 to better withstand the environmental stress caused by elevated CO 2 , promoting pyruvate fermentation and iron reduction. In addition to an increased pH, the formation of siderite, hematite and vivianite was also observed in the bioactive systems. Although both glass beads and quartz sand were primarily composed of silica, differences in the mineral structure, elemental composition and acid neutralization capacity rendered quartz sand more chemically active and unexpectedly led to greater CO 2 sequestration.

CO2 stress↗

Patch-level CO2 and CH4 fluxes and porewater concentrations in experimental wetlands, 2 PPT saltwater intrusion simulations, Aug-Oct 2022: Louisiana

This dataset contains carbon dioxide (CO2) and methane (CH4) flux measurements from patches of wetland vegetation dominated by Typha domingensis and Panicum hemitomon, which were conducted to assess flux responses to acute saltwater intrusion. The measurements occurred before, during, and after simulated acute saltwater intrusion events of low concentrations of ~ 2 PPT. The measurements comprise gas fluxes from the wetland surface (i.e., soil-water column and vegetation) and fluxes from the soil-water column exclusively. These two sets of fluxes are separated into two files and are complemented with four more files containing porewater concentrations of CO2 and CH4 collected at 0-5 cm, 10-15 cm, and 20-25 cm depth increments, spectral indices measurements, biomass, and sediment elevation table measurements. The files can be opened with regular text editors or spreadsheet programs.

54 ENVIRONMENTAL SCIENCES↗

Internal Active Thermal Control System (IATCS) Sodium Bicarbonate/Carbonate Buffer in an Open Aqueous Carbon Dioxide System and Corollary Electrochemical/Chemical Reactions Relative to System pH Changes

The International Space Station (ISS) Internal Active Thermal Control System (IATCS) experienced a number of chemical changes driven by system absorption of CO2 which altered the coolant’s pH. The natural effects of the decrease in pH from approximately 9.2 to less than 8.4 had immediate consequences on system corrosion rates and corrosion product interactions with specified coolant constituents. The alkalinity of the system was increased through the development and implementation of a carbonate/bicarbonate buffer that would increase coolant pH to 9.0 – 10.0 and maintain pH above 9.0 in the presence of ISS cabin concentrations of CO2 up to twenty times higher than ground concentrations. This paper defines how a carbonate/bicarbonate buffer works in an open carbon dioxide system and summarizes the analyses performed on the buffer for safe and effective application in the on-orbit system. The importance of the relationship between the cabin environment and the IATCS is demonstrated as the dominant factor in understanding the system chemistry and pH trends before and after addition of the carbonate/bicarbonate buffer. The paper also documents the corollary electrochemical and chemical reactions the system has experienced and the rationale for remediation of these effects with the addition of the carbonate/bicarbonate buffer.

Stegman, Thomas W.↗

Carbon Capture and Conversion

Worldwide concern over climate change and its consequences has become a regular topic in the news. Extremes of weather appear to be more and more commonplace all over the planet. Release of man-made carbon dioxide, a greenhouse gas, has been associated with climate change, as the levels of CO 2 have continued to increase at a steady rate. In response to this change, many scientists and engineers have began research either to look at ways to sequester carbon dioxide from the atmosphere or to capture it at its source to avoid having to concentrate the CO 2 from the air. At the same time, CO 2 has been highlighted as an inexpensive C1 carbon source, and research efforts are underway to use CO 2 directly in chemical production.

10 SYNTHETIC FUELS↗

Nitrogen nutrition and temporal effects of enhanced carbon dioxide on soybean growth

Plants grown on porous media at elevated CO2 levels generally have low concentrations of tissue N and often appear to require increased levels of external N to maximize growth response. This study determines if soybean [Glycine max (L.) Merr. Ransom'] grown hydroponically at elevated CO2 requires increases in external NO3- concentrations beyond levels that are optimal at ambient CO2 to maintain tissue N concentrations and maximize the growth response. This study also investigates temporal influences of elevated CO2 on growth responses by soybean. Plants were grown vegetatively for 34 d in hydroponic culture at atmospheric CO2 concentrations of 400, 650, and 900 microliters L-1 and during the final 18 d at NO3- concentrations of 0.5, 1.0, 5.0 and 10.0 mM in the culture solution. At 650 and 900 microliters L-1 CO2, plants had maximum increases of 31 and 45% in dry weight during the experimental period. Plant growth at 900 microliters L-1 CO2 was stimulated earlier than at 650 microliters L-1. During the final 18 d of the experiment, the relative growth rates (RGR) of plants grown at elevated CO2 declined. Elevated CO2 caused increases in total N and total NO3(-)-N content and leaf area but not leaf number. Enhancing CO2 levels also caused a decrease in root:shoot ratios. Stomatal resistance increased by 2.1- and 2.8-fold for plants at the 650 and 900 microliters L-1 CO2, respectively. Nitrate level in the culture solutions had no effect on growth or on C:N ratios of tissues, nor did increases in CO2 levels cause a decrease in N concentration of plant tissues. Hence, increases in NO3- concentration of the hydroponic solution were not necessary to maintain the N status of the plants or to maximize the growth response to elevated CO2.

NASA Program CELSS↗