Engineering Papers⌕ Search

SEARCH · Engineering Papers

Results for “camera system”

Search indexed NASA NTRS and DOE OSTI research on propulsion, heat transfer, battery materials and energy systems. Follow report and document links to the original sources.

Quote a phrase for an exact phrase match. Source license links do not imply unrestricted reuse.

At least 433 records · Page 24

Radiological Survey of Contaminated Installations of Research Reactor before Dismantling in High Dose Conditions with Complex for Remote Measurements of Radioactivity - 12069

Decontamination and decommissioning of the research reactors MR (Testing Reactor) and RFT (Reactor of Physics and Technology) has recently been initiated in the National Research Center (NRC) 'Kurchatov institute', Moscow. These research reactors have a long history and many installations - nine loop facilities for experiments with different kinds of fuel. When decommissioning nuclear facilities it is necessary to measure the distribution of radioactive contamination in the rooms and at the equipment at high levels of background radiation. At 'Kurchatov Institute' some special remote control measuring systems were developed and they are applied during dismantling of the reactors MR and RFT. For a survey of high-level objects a radiometric system mounted on the robotic Brokk vehicle is used. This system has two (4π and collimated) dose meters and a high resolution video camera. Maximum measured dose rate for this system is ∼8.5 Sv/h. To determine the composition of contaminants, a portable spectrometric system is used. It is a remotely controlled, collimated detector for scanning the distribution of radioactive contamination. To obtain a detailed distribution of contamination a remote-controlled gamma camera is applied. For work at highly contaminated premises with non-uniform background radiation, another camera is equipped with rotating coded mask (coded aperture imaging). As a result, a new system of instruments for remote radioactivity measurements with wide range of sensitivity and angular resolution was developed. The experience and results of measurements in different areas of the reactor and at its loop installations, with emphasis on the radioactive survey of highly-contaminated samples, are presented. These activities are conducted under the Federal Program for Nuclear and Radiation Safety of Russia. Adaptation of complex remote measurements of radioactivity and survey of contaminated installations of research reactor before dismantling in high dose conditions has proven successful. The radioactivity measuring devices for operation at high, non-uniform dose background were tested in the field and a new data of measurement of contamination distribution in the premises and installations were obtained. (authors)

12 MANAGEMENT OF RADIOACTIVE AND NON-RADIOACTIVE W↗

Real-Time Multi-Vehicle Multi-Camera Tracking with Graph-Based Tracklet Features

An essential application in intelligent transportation systems is multi-target multi-camera tracking (MTMCT), where the target’s activity is tracked from different cameras. Although the tracking-by-detection scheme is the primary paradigm in MTMCT, the object association information from the video frames is lost. This is mainly because the multi-camera multi-object matching uses the information from the video frames separately. To solve this problem and leverage this association information, we propose an MTMCT framework, where features are built in the form of a graph and a graph similarity algorithm is used to match multi-camera objects. In this paper, we focus on the real-time scenario, where only the past images are used to match an object. Our method achieves an IDF1 score (the ratio of the number of correctly identified objects to the number of ground truth and average objects) of 0.75 with a rate of 14 frames per second (fps).

Engineering↗

Real-time Awake Animal Motion Tracking System for SPECT Imaging

Enhancements have been made in the development of a real-time optical pose measurement and tracking system that provides 3D position and orientation data for a single photon emission computed tomography (SPECT) imaging system for awake, unanesthetized, unrestrained small animals. Three optical cameras with infrared (IR) illumination view the head movements of an animal enclosed in a transparent burrow. Markers placed on the head provide landmark points for image segmentation. Strobed IR LED s are synchronized to the cameras and illuminate the markers to prevent motion blur for each set of images. The system using the three cameras automatically segments the markers, detects missing data, rejects false reflections, performs trinocular marker correspondence, and calculates the 3D pose of the animal s head. Improvements have been made in methods for segmentation, tracking, and 3D calculation to give higher speed and more accurate measurements during a scan. The optical hardware has been installed within a Siemens MicroCAT II small animal scanner at Johns Hopkins without requiring functional changes to the scanner operation. The system has undergone testing using both phantoms and live mice and has been characterized in terms of speed, accuracy, robustness, and reliability. Experimental data showing these motion tracking results are given.

59 BASIC BIOLOGICAL SCIENCES↗

A compact neutron scatter camera for field deployment

Here, we describe a very compact (0.9 m high, 0.4 m diameter, 40 kg) battery operable neutron scatter camera designed for field deployment. Unlike most other systems, the configuration of the sixteen liquid-scintillator detection cells are arranged to provide omnidirectional (4π) imaging with sensitivity comparable to a conventional two-plane system. Although designed primarily to operate as a neutron scatter camera for localizing energetic neutron sources, it also functions as a Compton camera for localizing gamma sources. In addition to describing the radionuclide source localization capabilities of this system, we demonstrate how it provides neutron spectra that can distinguish plutonium metal from plutonium oxide sources, in addition to the easier task of distinguishing AmBe from fission sources.

46 INSTRUMENTATION RELATED TO NUCLEAR SCIENCE AND ↗

SU-E-J-12: An Image-Guided Soft Robotic Patient Positioning System for Maskless Head-And-Neck Cancer Radiotherapy: A Proof-Of-Concept Study

Purpose: We propose a surface-image-guided soft robotic patient positioning system for maskless head-and-neck radiotherapy. The ultimate goal of this project is to utilize a soft robot to realize non-rigid patient positioning and real-time motion compensation. In this proof-of-concept study, we design a position-based visual servoing control system for an air-bladder-based soft robot and investigate its performance in controlling the flexion/extension cranial motion on a mannequin head phantom. Methods: The current system consists of Microsoft Kinect depth camera, an inflatable air bladder (IAB), pressured air source, pneumatic valve actuators, custom-built current regulators, and a National Instruments myRIO microcontroller. The performance of the designed system was evaluated on a mannequin head, with a ball joint fixed below its neck to simulate torso-induced head motion along flexion/extension direction. The IAB is placed beneath the mannequin head. The Kinect camera captures images of the mannequin head, extracts the face, and measures the position of the head relative to the camera. This distance is sent to the myRIO, which runs control algorithms and sends actuation commands to the valves, inflating and deflating the IAB to induce head motion. Results: For a step input, i.e. regulation of the head to a constant displacement, the maximum error was a 6% overshoot, which the system then reduces to 0% steady-state error. In this initial investigation, the settling time to reach the regulated position was approximately 8 seconds, with 2 seconds of delay between the command start of motion due to capacitance of the pneumatics, for a total of 10 seconds to regulate the error. Conclusion: The surface image-guided soft robotic patient positioning system can achieve accurate mannequin head flexion/extension motion. Given this promising initial Result, the extension of the current one-dimensional soft robot control to multiple IABs for non-rigid positioning control will be pursued.

60 APPLIED LIFE SCIENCES↗

Model development for flash boiling spray and validations with isooctane, hexane, ethanol and their binary mixtures

The objective of this study is to develop a comprehensive model for spray atomization under the consideration of flash boiling, which includes nucleation, bubble growth, and droplet breakup. Although flash boiling has been previously studied, there is still no well-established analytical and numerical model of their mechanisms, or general guidelines on the implementation of this atomization strategy. In this study, detailed formulations are elaborated for the unified spray atomization model under both non-flash and flash boiling conditions. Next, the model was implemented into CFD software and 3-D simulations were performed for model validations. Two fuel blends are tested: ethanol-isooctane blends and hexane-isooctane blends. Simulation results were compared with the experimental measurements conducted using two methodologies, DBI (Diffuse Backlight Imaging) system for spray images captured by a high-speed camera, and a PDA (Phase Doppler Anemometry) system for droplet size measurement during the spray injection process. It was found that the current flash boiling model can accurately capture the spray characteristics under different environment conditions, such as the spray plume interactions and liquid penetration. The averaged Sauter mean diameter (SMD) calculations match the measurement sufficiently well. The spray structures for both single- and multi-component fuels during the injection process are well represented by current model.

42 ENGINEERING↗

Measurements of 3D slip velocities and plasma column lengths of a gliding arc discharge

A non-thermal gliding arc discharge was generated at atmospheric pressure in an air flow. The dynamics of the plasma column and tracer particles were recorded using two synchronized high-speed cameras. Whereas the data analysis for such systems has previously been performed in 2D (analyzing the single camera image), we provide here a 3D data analysis that includes 3D reconstructions of the plasma column and 3D particle tracking velocimetry based on discrete tomography methods. The 3D analysis, in particular, the determination of the 3D slip velocity between the plasma column and the gas flow, gives more realistic insight into the convection cooling process. Additionally, with the determination of the 3D slip velocity and the 3D length of the plasma column, we give more accurate estimates for the drag force, the electric field strength, the power per unit length, and the radius of the conducting zone of the plasma column.

71 CLASSICAL AND QUANTUM MECHANICS, GENERAL PHYSIC↗

Feasibility study of a high spatial and time resolution beam emission spectroscopy diagnostic for localized density fluctuation measurements in Lithium Tokamak eXperiment-β (LTX-β)

Trapped electron mode (TEM) is the main source of turbulence predicted for the unique operation regime of a flat temperature profile under low-recycling conditions in the LTX-β tokamak, while ion temperature gradient driven turbulence may also occur with gas fueling from the edge. To investigate mainly TEM scale density fluctuations, a high spatial and time resolution 2D beam emission spectroscopy (BES) diagnostic is being developed. Apart from spatially localized density turbulence measurement, BES can provide turbulence flow and flow shear dynamics. This BES system will be realized using an avalanche photodiode-based camera and narrow band interference filter. The system can acquire data at 2 MHz. Simulations with the Simulation of Spectra (SOS) code indicate that a high signal to noise ratio can be achieved with the proposed system. This will enable sampling the density fluctuations at this high time resolution. Finally, the design considerations and system optimization using the SOS code are presented.

70 PLASMA PHYSICS AND FUSION TECHNOLOGY↗

Determining Spatial Resolution of Gamma Cameras Using MATLAB

It is important to monitor the spatial resolution of a gamma camera on a weekly basis to acquire medical images with accurate quantitative information. A simple and fast computer program with a graphical user interface to analyze spatial resolution was successfully developed using MATLAB. The results were compared with those obtained from the standard processing system available in our gamma camera. The spatial resolution calculated using MATLAB was 1.24% lower than using the standard processing system. The developed program is cost effective, faster, and provides an easy platform for the physicists and technologists to analyze the spatial resolution based on the image of the line source.

46 INSTRUMENTATION RELATED TO NUCLEAR SCIENCE AND ↗

Management of the baseline shift using a new and simple method for respiratory-gated radiation therapy: Detectability and effectiveness of a flexible monitoring system

Purpose: In respiratory-gated radiation therapy, a baseline shift decreases the accuracy of target coverage and organs at risk (OAR) sparing. The effectiveness of audio-feedback and audio-visual feedback in correcting the baseline shift in the breathing pattern of the patient has been demonstrated previously. However, the baseline shift derived from the intrafraction motion of the patient's body cannot be corrected by these methods. In the present study, the authors designed and developed a simple and flexible system. Methods: The system consisted of a web camera and a computer running our in-house software. The in-house software was adapted to template matching and also to no preimage processing. The system was capable of monitoring the baseline shift in the intrafraction motion of the patient's body. Another marker box was used to monitor the baseline shift due to the flexible setups required of a marker box for gated signals. The system accuracy was evaluated by employing a respiratory motion phantom and was found to be within AAPM Task Group 142 tolerance (positional accuracy <2 mm and temporal accuracy <100 ms) for respiratory-gated radiation therapy. Additionally, the effectiveness of this flexible and independent system in gated treatment was investigated in healthy volunteers, in terms of the results from the differences in the baseline shift detectable between the marker positions, which the authors evaluated statistically. Results: The movement of the marker on the sternum [1.599 {+-} 0.622 mm (1 SD)] was substantially decreased as compared with the abdomen [6.547 {+-} 0.962 mm (1 SD)]. Additionally, in all of the volunteers, the baseline shifts for the sternum [-0.136 {+-} 0.868 (2 SD)] were in better agreement with the nominal baseline shifts than was the case for the abdomen [-0.722 {+-} 1.56 mm (2 SD)]. The baseline shifts could be accurately measured and detected using the monitoring system, which could acquire the movement of the marker on the sternum. The baseline shift-monitoring system with the displacement-based methods for highly accurate respiratory-gated treatments should be used to make most of the displacement-based gating methods. Conclusions: The advent of intensity modulated radiation therapy and volumetric modulated radiation therapy facilitates margin reduction for the planning target volumes and the OARs, but highly accurate irradiation is needed to achieve target coverage and OAR sparing with a small margin. The baseline shifts can affect treatment not only with the respiratory gating system but also without the system. Our system can manage the baseline shift and also enables treatment irradiation to be undertaken with high accuracy.

62 RADIOLOGY AND NUCLEAR MEDICINE↗

Improving 3D reconstruction quality for root phenotyping: assessing the impact of camera calibration and imaging parameters

Arate 3D reconstruction is essential for high-throughput plant phenotyping, particularly for studying complex structures such as root systems. While photogrammetry and Structure from Motion (SfM) techniques have become widely used for 3D root imaging, the camera settings used are often underreported in studies, and the impact of camera calibration on model accuracyccu remains largely underexplored in plant science. In this study, we systematically evaluate the effects of focus, aperture, exposure time, and gain settings on the quality of 3D root models made with a multi-camera scanning system. We show through a series of experiments that calibration significantly improves model quality, with focus misalignment and shallow depth of field (DoF) being the most important factors affecting reconstruction accuracy. Our results further show that proper calibration has a greater effect on reducing noise than filtering it during post-processing, emphasizing the importance of optimizing image acquisition rather than relying solely on computational corrections. This work improves the repeatability and accuracy of 3D root imaging for phenotyping pipelines by giving useful calibration guidelines. This leads to better trait quantification for use in crop research and plant breeding in downstream analysis.

3D reconstruction↗

Video Camera Improvements to Support Hanford Tank Farms - 17141

Hanford Tank Farms consist of 177 underground storage tanks that contain 56 million gallons of radioactive waste. The current mission is to safely manage this waste in preparation to feed the Waste Treatment Plant. Fulfilling this mission includes inspecting each tank regularly to ensure tank integrity and support ongoing operations such as transferring waste from older single-shell tanks to the newer double-shell tanks. Video cameras derived from commercially available equipment have provided the ability to remotely see inside the tanks, reducing some of the challenges of fulfilling this mission. However, there are many challenges and limitations with the currently used video systems. Among some of the challenges are limited tank interior entry points for camera deployment, high radiation dose rates, limited equipment longevity in the environmental conditions, need for high resolution image quality, low light conditions, and in-tank obstructions. Washington River Protection Solutions (WRPS) has identified and tested new video systems that will effectively manage these challenges and increase capability, efficiency, and improve safety. The new camera systems are planned for deployment to support the next Single Shell Tank Retrieval Project in the A/AX tank Farm complex. (authors)

12 MANAGEMENT OF RADIOACTIVE AND NON-RADIOACTIVE W↗

Imaging vs. non-imaging in long range neutron detection scenarios.

Standoff neutron detection technology has advanced in recent years, primarily for counterterrorism applications. Sandia National Laboratories has developed the Neutron Scatter Camera -- a fast neutron imaging system using liquid scintillator with potential applications in long range neutron detection. This talk will explore the pros, cons and practical uses of the Neutron Scatter Camera versus more traditional neutron detectors such as He-3 proportional counters. Several applications for neutron detection and imaging will be explored. We will perform predictive calculations of the response of the Neutron Scatter Camera and traditional He-3 detectors. The applications range from counterterrorism to arms control to safeguards. We will discuss future evolution of the scatter camera to enhance long range detection.

46 INSTRUMENTATION RELATED TO NUCLEAR SCIENCE AND ↗

Active beam position stabilization of pulsed lasers for long-distance ion profile diagnostics at the Spallation Neutron Source (SNS)

A high peak-power Q-switched laser has been used to monitor the ion beam profiles in the superconducting linac at the Spallation Neutron Source (SNS). The laser beam suffers from position drift due to movement, vibration, or thermal effects on the optical components in the 250-meter long laser beam transport line. We have designed, bench-tested, and implemented a beam position stabilization system by using an Ethernet CMOS camera, computer image processing and analysis, and a piezo-driven mirror platform. The system can respond at frequencies up to 30 Hz with a high position detection accuracy. With the beam stabilization system, we have achieved a laser beam pointing stability within a range of 2 rad (horizontal) to 4 rad (vertical), corresponding to beam drifts of only 0.5 mm 1 mm at the furthest measurement station located 250 meters away from the light source.

43 PARTICLE ACCELERATORS↗

Final Scientific/Technical Report: Real Time Particle Size and Settling Velocity for In-Situ Monitoring of Deep-Sea Polymetallic Nodule Mining

In the coming decade, it is anticipated that deep-sea mining activities will commence throughout the deep ocean, at depths around 4000-6000m where vast deposits of baseball-sized rocks called polymetallic nodules lay on the seabed. These nodules contain resources such as cobalt, copper and nickel which are needed to produce batteries for electric vehicles. Collector machines driving on the seabed and gathering these nodules will stir up clouds of sediment, and there is concern about how the resulting concentration of sediment in the near-bottom ocean water will affect deep and mid-ocean biology. There is currently no technology capable of comprehensively monitoring the concentrations and properties of stirred up sediment in the deep. This project addressed this critical gap by developing a deep-sea particle measurement system (Real-Time Size and Settling Velocity, RTSSV) that uses a multi-camera high-resolution video imaging system, with accompanying image processing, to measure the concentration, size distribution and settling speed of sediment. Importantly, these measurements are made in-situ, so that delicate sediment aggregates will not be disturbed, as is the case when collecting samples at depth to be measured in the lab. The instrument can be mounted on a variety of established deep-sea platforms such as moorings, AUVs and ROVs, providing data in near real time, where the key measurements need to be made—from the source of the sediment disturbance and throughout the resulting plume—vital for determining if deep-sea mining can be done in an environmentally responsible manner. The developed system (RTSSV) will possess the only such capability worldwide, giving a US-based group a substantial competitive advantage as this newly evolving global industry develops. As added value, the technology will also have widespread application to the offshore oil and gas industry, dredging industry, and to sediment science research.

47 OTHER INSTRUMENTATION↗

High Dose Rate Irradiations of Enduray Vision System for Nuclear Inspections

Higher radiation-hardened video cameras are needed in the operation and remote handling of equipment in nuclear reactor inspection and refueling applications. Vega Wave Systems, Inc. has developed a radiation-hardened vision system for nuclear energy applications. This vision system has been developed under several small business innovative research programs (SBIRs) from the U.S. Department of Energy, and the previous GAIN voucher program at Argonne National Laboratory (ANL) was successful in demonstrating that a prototype of the camera is radiation-hard up to at least 525 kGy (5.25 × 106 rad, Si equivalent) at dose rates of 10 kGy/hr with no measurable degradation in image quality and no measurable radiation-induced noise (RIN). Vega Wave Systems has developed a new version of the camera with more than 3X the resolution using a new design and new components, and this new design requires radiation-hardness qualification for marketplace acceptance. The program described in this report provided high radiation-hardness testing of this redesigned high-resolution vision system using the Argonne Low-Energy Accelerator Facility (LEAF). This report presents the results of irradiation tests performed on Vega Wave System’s redesigned high resolution vision system at a dose rate of 9.3 kGy/hr and up to total doses of 1823 kGy. This was an accumulation of 197 hours of irradiation. The results were excellent, providing proof of the redesigned high-resolution vision system’s immunity to high levels of radiation.

42 ENGINEERING↗

SU-F-T-640: Feasibility of Using a Commercially Available Surface Guided Radiotherapy System with An Open-Face SRS Immobilization System

Purpose: To evaluate the inherent accuracy of using a surface guided radiotherapy system (SGRT) in the setup and monitoring of patients receiving stereotactic radiosurgery with an open-face SRS immobilization system. Methods: An anthropomorphic head phantom was set up using the Qfix Encompass SRS Immobilization System on a Varian Edge with OSMS and Varian TrueBeam with AlignRT. The phantom was positioned at 0° gantry and couch. A reference image was acquired using the SGRT system and an ROI was created over the mask opening. The couch and gantry were rotated to different combinations focusing on clinically used SRS gantry/couch combinations and those blocking the SGRT cameras. Perceived surface deviation by the SGRT system from the reference image was recorded. A Winston-Lutz test was performed on couch angles tested and used to exclude couch walkout. The deviation magnitude was calculated using translational values and rotational raw values were recorded. Results: The maximum couch walkouts were: 0.4mm (Edge) and 0.5mm (TB). Solely rotating the gantry resulted in a median couch deviation of 0.2mm and range of 0.1–0.3mm for both linacs. Only rotating the couch (0° gantry) resulted in median deviations of 0.6mm and 0.5mm with ranges of 0.3–1.0mm and 0.3–0.7mm for the Edge and TB, respectively. Combining gantry and couch rotations, the median deviations were 0.7mm and 0.9mm with ranges of 0.3–1.1mm and 0.2–1.9mm for the Edge and TB, respectively. Including all combinations, rotation, roll, and pitch median deviations ranged from 0.1–0.3° with pitch demonstrating consistently higher values and a maximum deviation of 1.0° (both linacs). Conclusion: SGRT is a reliable monitoring tool, though taking into account system fluctuations, 1mm is too restrictive a site tolerance to use with the Qfix Encompass mask. Gantry rotation has little effect on system fluctuation even with camera blockage, whereas couch rotation has a larger effect.

43 PARTICLE ACCELERATORS↗

Spectrally resolved polarization angle across the motional Stark effect spectrum

A new diagnostic technique has been developed that couples a spectrometer and an image-intensified camera into the traditional motional Stark effect (MSE) system on DIII-D. The image-intensified camera syncs with the photo-elastic modulators to spectrally resolve the Stokes parameters across the Stark multiplet. Polarization dependent phase shift, likely from a plasma facing mirror, leads to the spectropolarimeter measuring a variation in the polarization angle across the MSE spectrum of ∼8°.

Victor, B. S. (ORCID:0000000212512922)↗