Engineering Papers⌕ Search

SEARCH · Engineering Papers

Results for “calibration methods”

Search indexed NASA NTRS and DOE OSTI research on propulsion, heat transfer, battery materials and energy systems. Follow report and document links to the original sources.

Quote a phrase for an exact phrase match. Source license links do not imply unrestricted reuse.

At least 433 records · Page 24

A gain series method for accurate EMCCD calibration

Abstract Calibration of the gain and digital conversion factor of an EMCCD is necessary for accurate photon counting. We present a new method to quickly calibrate multiple gain settings of an EMCCD camera. Acquiring gain-series calibration data and analyzing the resulting images with the EMCCD noise model more accurately estimates the gain response of the camera. Furthermore, we develop a method to compare the results from different calibration approaches. Gain-series calibration outperforms all other methods in this self-consistency test.

36 MATERIALS SCIENCE↗

Determination of diffusion lengths in silicon by an X-ray method

By calibrating X-ray machine with cells of known diffusion lengths, measurements on test cells can be madeate rate of one every two minutes with standard deviation of less than two percent. test cells are compared with calibration cells whose diffusion lengths have been measured by an electron beam method.

Lamneck, J. H., Jr.↗

Measurements of Temperature Variations in the Atmosphere near the Tropopause with Reference to Airspeed Calibration by the Temperature Method

Measurements of temperature variations in the atmosphere near the tropopause over land in the vicinity of Langley Field, Va., are presented. This investigation was made for the purpose of obtaining information on the accuracy of the temperature method(NACA TN 2046) of airspeed calibration over the range of Mach number from 0.6 to .08. The temperature surveys and the description of a specially designed thermometer are also presented.

INSTRUMENTS, METEOROLOGICAL↗

Automatic PCM guard-band selector and calibrator

Automatic method for selection of proper guard band eliminates human error and speeds up calibration process. There is also an option which allows a single channel to be calibrated, independently of other channels. Entire system is designed on 3- by 4-inch printed-circuit cards and may be used with any pulse code modulation system.

Noda, T. T.↗

Utilizing Brightness Temperature Histograms for Microwave Radiometer High Frequency (150-183 Ghz) Calibration

Spaceborne microwave radiometers with high frequency channels (150-183 GHz) are important for retrieving many geophysical parameters such as snowfall, ice water path, and atmospheric water vapor profiles. In order to obtain accurate retrievals from the brightness temperature measurements, the radiometers must be properly calibrated. Several methods have been developed to analyze the on-orbit calibration, including comparisons with radiative transfer models, comparisons with radiosonde profiles, and cross-calibration with similar radiometers. This paper introduces a new method to calibrate high frequency channels that utilizes TB histograms. This new method gives an independent approach that can be used by itself to analyze radiometer calibration or in conjunction with other methods to corroborate results.

microwave radiometry↗

Application of a Semiparametric Statistical Method to Spacecraft Sensor and Calibration Data

A semiparametric statistical method is applied to spacecraft sensor data and spacecraft sensor residual data. The method stipulates a reference distribution and deviations from it. The problem is to estimate the reference distribution and the distorted distributions from all available data from all the sources under consideration. The problem can be solved by assuming a distortion form and independent data.

Kedem, Benjamin↗

Theoretical research program to study chemical reactions in AOTV bow shock tubes

The main focus was the development, implementation, and calibration of methods for performing molecular electronic structure calculations to high accuracy. These various methods were then applied to a number of chemical reactions and species of interest to NASA, notably in the area of combustion chemistry. Among the development work undertaken was a collaborative effort to develop a program to efficiently predict molecular structures and vibrational frequencies using energy derivatives. Another major development effort involved the design of new atomic basis sets for use in chemical studies: these sets were considerably more accurate than those previously in use. Much effort was also devoted to calibrating methods for computing accurate molecular wave functions, including the first reliable calibrations for realistic molecules using full CI results. A wide variety of application calculations were undertaken. One area of interest was the spectroscopy and thermochemistry of small molecules, including establishing small molecule binding energies to an accuracy rivaling, or even on occasion surpassing, the experiment. Such binding energies are essential input to modeling chemical reaction processes, such as combustion. Studies of large molecules and processes important in both hydrogen and hydrocarbon combustion chemistry were also carried out. Finally, some effort was devoted to the structure and spectroscopy of small metal clusters, with applications to materials science problems.

Taylor, Peter R.↗

Photometric calibration in u -band using blue halo stars

ABSTRACT We develop a method to calibrate u-band photometry based on the observed colour of blue Galactic halo stars. The Galactic halo stars belong to an old stellar population of the Milky Way and have relatively low metallicity. The ‘blue tip’ of the halo population – the main sequence turn-off (MSTO) stars – is known to have a relatively uniform intrinsic edge u-g colour with only slow spatial variation. In SDSS data, the observed variation is correlated with Galactic Latitude, which we attribute to contamination by higher metallicity disc stars and fit with an empirical curve. This curve can then be used to calibrate u-band imaging if g-band imaging of matching depth is available. Our approach can be applied to single-field observations at |b| > 30°, and removes the need for standard star observations or overlap with calibrated u-band imaging. We include in our method the calibration of g-band data with ATLAS-Refcat2. We test our approach on stars in KiDS DR 4, ATLAS DR 4, and DECam imaging from the NOIRLab Source Catalog (NSC DR2), and compare our calibration with SDSS. For this process, we use synthetic magnitudes to derive the colour equations between these data sets, in order to improve zero-point accuracy. We find an improvement for all data sets, reaching a zero-point precision of 0.016 mag for KiDS (compared to the original 0.033 mag), 0.020 mag for ATLAS (originally 0.027 mag), and 0.016 mag for DECam (originally 0.041 mag). Thus, this method alone reaches the goal of 0.02 mag photometric precision in u-band for the Rubin Observatory’s Legacy Survey of Space and Time (LSST).

79 ASTRONOMY AND ASTROPHYSICS↗

Remote Sensing Requirements Development: A Simulation-Based Approach

Earth science research and application requirements for multispectral data have often been driven by currently available remote sensing technology. Few parametric studies exist that specify data required for certain applications. Consequently, data requirements are often defined based on the best data available or on what has worked successfully in the past. Since properties such as spatial resolution, swath width, spectral bands, signal-to-noise ratio (SNR), data quantization and band-to-band registration drive sensor platform and spacecraft system architecture and cost, analysis of these criteria is important to optimize system design objectively. Remote sensing data requirements are also linked to calibration and characterization methods. Parameters such as spatial resolution, radiometric accuracy and geopositional accuracy affect the complexity and cost of calibration methods. However, few studies have quantified the true accuracies required for specific problems. As calibration methods and standards are proposed, it is important that they be tied to well-known data requirements. The Application Research Toolbox (ART) developed at the John C. Stennis Space Center provides a simulation-based method for multispectral data requirements development. The ART produces simulated datasets from hyperspectral data through band synthesis. Parameters such as spectral band shape and width, SNR, data quantization, spatial resolution and band-to-band registration can be varied to create many different simulated data products. Simulated data utility can then be assessed for different applications so that requirements can be better understood.

Zanoni, Vicki↗

Remote Sensing System Requirements Development: A Simulation-Based Approach

Earth science research and application requirements for multispectral data have often been driven by currently available remote sensing technology. Few parametric studies exist that specify data required for certain applications. Consequently, data requirements are often defined based on the best data available or on what has worked successfully in the past. Since properites such as spatial resolution, swath width, spectral bands, signal-to-noise ratio (SNR), data quantization, and band-to-band registration drive sensor platform and spaceraft system architecture and cost, analysis of these criteria is important to objectively optimize system design. Remote sensing data requirements are also linked to calibration and characterization methods. Parameters such as spatial resolution, radiometric accuracy, and geopositional accuracy affect the complexity and cost of calibration methods. However, there are few studies that quantify the true accuracies required for specific problems. As calibration methods and standards are proposed, it is important that they be tied to well-known data requirements. The Application Research Toolbox (ART) developed at Stennis Space Center provides a simulation-based method for multispectral data requirements development. The ART produces simulated data sets from hyperspectral data through band synthesis. Parameters such as spectral band shape and width, SNR, data quantization, spatial resolution, and band-to-band registration can be varied to create many different simulated data products. Simulated data utility can then be assessed for different applications so that requirements can be better understood. This paper describes the ART and its applicability for rigorously deriving remote sensing data requirements.

Zanoni, Vicki↗

Methods and apparatus for calibration and response time testing of level sensors

Systems and methods of diagnosing performance of a level sensor of a fluid test chamber, including a data acquisition and processing unit configured to receive output signals of one or more level sensors that are installed to a fluid chamber, the data acquisition and processing unit being configured to connect to the one or more level sensors to record and process the output signals to test operation of the one or more level sensors.

Hashemian, Alexander Hashem↗

A Non-Radiative Transfer Approach to Radiometric Vicarious Calibration

TOA (top-of-atmosphere) radiance from high-spatial-resolution satellite imagery systems is important for a wide variety of research and applications. Many research initiatives require data with absolute radiometric accuracy better than a few percent. The conversion of satellite digital numbers to radiance depends on accurate radiometric calibration. A common method for determining and validating radiometric calibrations is to rely upon vicarious calibration approaches. Historically, vicarious calibration methods use radiative transfer codes with ground-based atmosphere and surface reflectance or radiance inputs for estimating TOA radiance values. These TOA radiance values are compared against the satellite digital numbers to determine the radiometric calibration. However, the radiative transfer codes used depend on many assumptions about the aerosol properties and the atmospheric point spread function. A measurement-based atmospheric radiance estimation approach for high-spatial-resolution, multispectral, visible/near-infrared sensors is presented that eliminates the use of radiative transfer codes and many of the underlying assumptions. A comparison between the radiative transfer and non-radiative transfer approaches is made.

Ryan, Robert↗

Absolute mass calibration of fission product distributions measured with the E-$v$ method

The mass calibration of fission product distributions measured with the energy–velocity (E-v) method constitutes a technical challenge. The energy loss of the fission fragments in the various dead layers of the spectrometer and other sources of pulse-height defects of the energy detectors are a significant source of systematic uncertainty in the mass calculations used to determine the measured fission product yields. Here, in this study, the absolute calibration of the fission mass distributions is accomplished by measuring prompt γ-rays in coincidence with the fission fragments. This allows for the direct calibration of the mass spectra and eliminates any dependence on potentially complicated energy corrections. The first test measurement was performed at the Los Alamos Neutron Science Center employing the SPectrometer for Ion DEtermination in fission Research (SPIDER). SPIDER is a 2E-2v spectrometer designed for measuring independent fission product yields from neutron-induced fission. In this test, the single-arm SPIDER (E-v) system and an array of 252 Cf sources were used. The single-arm system consisted of two time pick-off detectors for measuring the time-of-flight of the fission fragments and a double-sided silicon strip detector (DSSD) for measuring the kinetic energy. Characteristic γ-rays from fission fragments were detected using three high-purity germanium (HPGe) detectors. For the mass calibration, γ–mass coincidence events from twelve product isotopes were used. The measured FPYs from 252 Cf spontaneous fission were found to be in excellent agreement with the evaluated data after applying the absolute mass calibration. From the γ–mass coincidence events, the mass resolution of the system was also extracted. An average mass resolution of ~1.4 AMU (FWHM) for the light fragments and ~2.4 AMU (FWHM) for the heavy fragments were found. This was the first in-situ calibration and characterization of the SPIDER spectrometer, which paves the way for high-quality FPY measurements with this instrument.

46 INSTRUMENTATION RELATED TO NUCLEAR SCIENCE AND ↗

Black carbon aerosol number and mass concentration measurements by picosecond short-range elastic backscatter lidar

Abstract Black carbon aerosol emissions are recognized as contributors to global warming and air pollution. There remains, however, a lack of techniques to remotely measure black carbon aerosol particles with high range and time resolution. This article presents a direct and contact-free remote technique to estimate the black carbon aerosol number and mass concentration at a few meters from the emission source. This is done using the Colibri instrument based on a novel technique, referred to here as Picosecond Short-Range Elastic Backscatter Lidar (PSR-EBL). To address the complexity of retrieving lidar products at short measurement ranges, we apply a forward inversion method featuring radiometric lidar calibration. Our method is based on an extension of a well-established light-scattering model, the Rayleigh–Debye–Gans for Fractal-Aggregates (RDG-FA) theory, which computes an analytical expression of lidar parameters. These parameters are the backscattering cross-sections and the lidar ratio for black carbon fractal aggregates. Using a small-scale Jet A-1 kerosene pool fire, we demonstrate the ability of the technique to quantify the aerosol number and mass concentration with centimetre range-resolution and millisecond time-resolution.

46 INSTRUMENTATION RELATED TO NUCLEAR SCIENCE AND ↗

Volumetric calibration of a propellant utilization system

Method of calibrating capacitance-type propellant mass sensors provides meaningful mass units accurate to within one percent of the total load. Neither special propellant loading nor test firing is required. Recalibration of the system is possible without special propellant loading. This method provides increased flexibility for vehicle operation.

Lenning, J. J.↗

Improved Calibration Of Acoustic Plethysmographic Sensors

Improved method of calibration of acoustic plethysmographic sensors involves acoustic-impedance test conditions like those encountered in use. Clamped aluminum tube holds source of sound (hydrophone) inside balloon. Test and reference sensors attached to outside of balloon. Sensors used to measure blood flow, blood pressure, heart rate, breathing sounds, and other vital signs from surfaces of human bodies. Attached to torsos or limbs by straps or adhesives.

Zuckerwar, Allan J.↗

Results from the first international AM0

AM0 solar cell calibration laboratories throughout the world are working together to create standard methods for AM0 calibration. In an effort to compare the results of different calibration methods, five different laboratories calibrated GaAs and Si solar cells. The results of this inter-comparison are presented herein.

round robin solar cells AM0 silicon GaAs internati↗

Calibration of the Urbana lidar system

A method for calibrating data obtained by the Urban sodium lidar system is presented. First, an expression relating the number of photocounts originating from a specific altitude range to the soodium concentration is developed. This relation is then simplified by normalizing the sodium photocounts with photocounts originating from the Rayleigh region of the atmosphere. To evaluate the calibration expression, the laser linewidth must be known. Therefore, a method for measuring the laser linewidth using a Fabry-Perot interferometer is given. The laser linewidth was found to be 6 + or - 2.5 pm. Problems due to photomultiplier tube overloading are discussed. Finally, calibrated data is presented. The sodium column abundance exhibits something close to a sinusoidal variation throughout the year with the winter months showing an enhancement of a factor of 5 to 7 over the summer months.

Cerny, T.↗