Engineering Papers⌕ Search

SEARCH · Engineering Papers

Results for “calibration”

Search indexed NASA NTRS and DOE OSTI research on propulsion, heat transfer, battery materials and energy systems. Follow report and document links to the original sources.

Quote a phrase for an exact phrase match. Source license links do not imply unrestricted reuse.

At least 433 records · Page 24

A deep learning-based Bayesian framework for high-resolution calibration of building energy models

Calibrating building energy models (BEMs), i.e., closing discrepancy between modeling and field measurements, is of significance to support its applications in building sustainability and resilience analysis. However, as being widely used in practice, current Bayesian calibration is mostly performed in low-resolution (annual or monthly), instead of high-resolution (hourly or sub-hourly), which is crucial to support emerging BEM applications, such as building-renewable energy integration (demand response) and smart control. This is attributable to the gaps in current Bayesian calibration process, including (1) difficulty in supporting reliable high-resolution calibration with over-parameterization and multi-solution issues, (2) inadequacy of meta-model to capture temporal building dynamics in high-resolution, and (3) excessive computational burdens of covariance matrix calculation in Bayesian inference. Therefore, to close these gaps, this research proposes a novel deep learning-based Bayesian calibration framework, involving pre-calibration mechanism, Long Short-Term Memory as surrogate models, and simplified covariance matrix calculation, to calibrate BEMs in high temporal resolution (i.e., hourly) with enhanced accuracy and computational efficiency. Finally, the case study demonstrates its effectiveness to match modeling outcomes with measurements and realize CV-RMSE of < 30 % and NMBE of < 6 % in hourly resolution, as well as a significant reduction of calibration time (by > 99 %, from > 600 h to ~ 1.5 h).

32 ENERGY CONSERVATION, CONSUMPTION, AND UTILIZATI↗

In situ broadband cryogenic calibration for two-port superconducting microwave resonators

We introduce an improved microwave calibration method for use in a cryogenic environment, based on a traditional three-standard calibration, the Thru-Reflect-Line (TRL) calibration. The modified calibration method takes advantage of additional information from multiple measurements of an ensemble of realizations of a superconducting resonator, as a new pseudo-Open standard, to correct errors in the TRL calibration. We also demonstrate an experimental realization of this in situ broadband cryogenic calibration system utilizing cryogenic switches. All calibration measurements are done in the same thermal cycle as the measurement of the resonator (requiring only an additional 20 min), thus avoiding 4 additional thermal cycles for traditional TRL calibration (which would require an additional 12 days). The experimental measurements on a wave-chaotic microwave billiard verify that the new method significantly improves the measured scattering matrix of a high-quality-factor superconducting resonator.

46 INSTRUMENTATION RELATED TO NUCLEAR SCIENCE AND ↗

The NASA OBPG 2020 On-Orbit Calibration of SNPP VIIRS for Ocean Color Applications

The NASA Ocean Biology Processing Group (OBPG) has continued monitoring the SNPP VIIRS on-orbit calibration for bands M1-M11 over its mission to optimize the calibration for ocean color applications. The OBPG has recently implemented several changes to the calibration scheme: using solar-derived f-factors to detrend the lunar observations; using long-term exponentials of time as basis vectors (along with libration angles) for radiometric fits to any resulting lunar temporal drifts; deriving gain adjustments to the solar f-factors from these exponentials; and deriving gain adjustments due to modulated RSRs outside of the solar/lunar calibration using TOA reference spectra. These calibration changes minimize the impact of uncertainties in any one component of the calibration on the derived f-factors. The final f-factors incorporate VIIRS solar diffuser measurements, h-factor BRDF corrections, lunar-derived gains, and modulated RSR gains. The combined BRDF corrections, lunar gain adjustments, and mRSR gain adjustments define effective h-factors for each band. The improvements in the on-orbit calibration are validated by evaluation of globally-derived anomaly plots of remote sensing reflectance for the ocean color bands. The ultimate goal of the OBPG calibration effort is incorporation of a consistent SNPP VIIRS ocean color data set into the NASA multi-mission ocean color climate data record.

VIIRS↗

Independent Calibration Approach for the CLARREO Pathfinder Mission

A CLARREO (Climate Absolute Radiance and Refractivity Observatory) Pathfinder (CPF) mission has been funded to demonstrate retrieval of SI-traceable spectral reflectance with absolute uncertainty <0.3% (k=1). The mission consists of a Reflected Solar spectrometer that will be hosted on the International Space Station (ISS) in the 2023 timeframe and rely on a ratioing radiometer approach to retrieve the unprecedented accuracy. Demonstrating that the accuracy is achieved through an Independent Calibration effort similar in philosophy to the efforts in metrology laboratories relying on multiple, independent measurements to improve credibility for a sensor’s absolute and relative uncertainty error budgets. These measurements use different traceability paths and multiple instrument approaches and CPF’s Independent Calibration will be similar in this regard. The Independent Calibration relies on a pre-launch absolute radiometric calibration obtained from additional testing done after instrument thermal-vacuum (TVAC) testing. The added radiometric calibration is combined with a high fidelity instrument model to provide an on-orbit radiometric calibration independent from the ratioing radiometer approach. The current work describes the post-TVAC testing portion of the CPF Independent Calibration Plan and the Independent Model Development as well as planned on-orbit Evaluation of the Independent Calibration.

CLARREO Pathfinder↗

Aqua MODIS: 20 Years of On-orbit Calibration and Performance

Since its launch in May 2002, Aqua MODIS has successfully operated for more than 20 years and has continuously generated a wide range of data products that have enabled and supported the remote sensing community and users worldwide for their studies of the Earth’s system by monitoring changes in its key environmental parameters. Although Aqua MODIS, designed with a lifetime requirement of 6 years, is currently operated in its extended mission phase, it continues to make high quality global observations of the Earth’s surface via its 36 spectral bands that cover wavelengths from visible to long-wave infrared. To date, all instrument on-board calibrators (OBC) remain capable of performing their design functions, providing various calibration data sets to help monitor on-orbit changes in sensor responses and performance characteristics. In addition to the OBC, regularly scheduled lunar observations and select Earth-view targets are used extensively to support sensor on-orbit calibration, especially for the calibration of the visible channels (or bands). In this paper, we provide an overview of Aqua MODIS on-orbit calibration activities and methodologies for both reflective solar bands (RSB) and thermal emissive bands (TEB), illustrate its on-orbit performance over the past 20 years using examples derived from OBC measurements, lunar observations, and Earth-view response trends, and describe various calibration improvements made over its entire mission. We focus on key issues identified since launch, such as solar diffuser degradation, electronic crosstalk, and on-orbit changes in sensor response versus scan-angle, along with approaches and strategies developed to mitigate their impact on sensor calibration quality. Also discussed in this paper are some of the key calibration enhancements incorporated recently in the Collection 6.1 and the upcoming Collection 7 Level-1B algorithms.

Polarization↗

Radiometer calibration methods and resulting irradiance differences

Accurate solar radiation measured by radiometers depends on instrument performance specifications, installation method, calibration procedure, measurement conditions, maintenance practices, location, and environmental conditions. This study addresses the effect of different calibration methodologies and resulting differences provided by radiometric calibration service providers such as the National Renewable Energy Laboratory (NREL) and manufacturers of radiometers. Some of these methods calibrate radiometers indoors and some outdoors. To establish or understand the differences in calibration methodologies, we processed and analyzed field-measured data from radiometers deployed for 10 months at NREL's Solar Radiation Research Laboratory. These different methods of calibration resulted in a difference of ±1% to ±2% in solar irradiance measurements. Here by analyzing these differences will ultimately assist in determining the uncertainties of the field radiometer data and will help develop a consensus on a standard for calibration. Further advancing procedures for precisely calibrating radiometers to world reference standards that reduce measurement uncertainties will help the accurate prediction of the output of planned solar conversion projects and improve the bankability of financing solar projects.

14 SOLAR ENERGY↗

Subwavenumber charge-coupled device spectrometer calibration using molecular iodine laser-induced fluorescence

Spectrometers configured with charge-coupled devices (CCD) or other array-based detectors require calibration to convert from the pixel coordinate to a spectral coordinate. A CCD calibration method well suited for Raman spectroscopy has been developed based on the 514.5 nm Ar{sup +} laser-induced fluorescence (LIF) spectrum of room-temperature molecular iodine vapor. Over 360 primary and secondary I{sub 2} LIF calibration lines spanning 510-645 nm were identified as calibrant peaks using an instrumental resolution of 1 cm{sup -1}. Two instrument calibration functions were evaluated with these peaks: a second-order polynomial and a function derived from simple optomechanical considerations. The latter function provided better fitting characteristics. Calibration using I{sub 2} LIF was tested with measurements of both laser light scattering and Raman spectra. The I{sub 2} LIF reference spectra and the signal spectra were recorded simultaneously, with no cross talk, by separating the two signals spatially along the vertical axis of the CCD imager. In this way, every CCD image could be independently calibrated. An accuracy and a precision of {+-}0.05 cm{sup -1} were achieved with this calibration technique.

46 INSTRUMENTATION RELATED TO NUCLEAR SCIENCE AND ↗

Piezoelectric Shaker Development for High Frequency Calibration of Accelerometers

Calibration of vibration transducers requires sinusoidal motion over a wide frequency range with low distortion and low cross-axial motion. Piezoelectric shakers are well suited to generate such motion and are suitable for use with laser interferometric methods at frequencies of 3 kHz and above. An advantage of piezoelectric shakers is the higher achievable accelerations and displacement amplitudes as compared to electro-dynamic (ED) shakers. Typical commercial ED calibration shakers produce maximum accelerations from 100 m/s{sup 2} to 500 m/s{sup 2}. Very large ED shakers may produce somewhat higher accelerations but require large amplifiers and expensive cooling systems to dissipate heat. Due to the limitations in maximum accelerations by ED shakers at frequencies above 5 kHz, the amplitudes of the generated sinusoidal displacement are frequently below the resolution of laser interferometers used in primary calibration methods. This limits the usefulness of ED shakers in interferometric based calibrations at higher frequencies.Small piezoelectric shakers provide much higher acceleration and displacement amplitudes for frequencies above 5 kHz, making these shakers very useful for accelerometer calibrations employing laser interferometric measurements, as will be shown in this paper. These piezoelectric shakers have been developed and used at NIST for many years for high frequency calibration of accelerometers. This paper documents the construction and performance of a new version of these shakers developed at NIST for the calibration of accelerometers over the range of 3 kHz to 30 kHz and possibly higher. Examples of typical calibration results are also given.

46 INSTRUMENTATION RELATED TO NUCLEAR SCIENCE AND ↗

Dry calibration of electromagnetic flowmeters based on numerical models combining multiple physical phenomena (multiphysics)

This paper presents a method for dry calibration of an electromagnetic flowmeter (EMF). This method, which determines the voltage induced in the EMF as conductive liquid flows through a magnetic field, numerically solves a coupled set of multiphysical equations with measured boundary conditions for the magnetic, electric, and flow fields in the measuring pipe of the flowmeter. Specifically, this paper details the formulation of dry calibration and an efficient algorithm (that adaptively minimizes the number of measurements and requires only the normal component of the magnetic flux density as boundary conditions on the pipe surface to reconstruct the magnetic field involved) for computing the sensitivity of EMF. Along with an in-depth discussion on factors that could significantly affect the final precision of a dry calibrated EMF, the effects of flow disturbance on measuring errors have been experimentally studied by installing a baffle at the inflow port of the EMF. Results of the dry calibration on an actual EMF were compared against flow-rig calibration; excellent agreements (within 0.3%) between dry calibration and flow-rig tests verify the multiphysical computation of the fields and the robustness of the method. As requiring no actual flow, the dry calibration is particularly useful for calibrating large-diameter EMFs where conventional flow-rig methods are often costly and difficult to implement.

75 CONDENSED MATTER PHYSICS, SUPERCONDUCTIVITY AND↗

Towards improved local hybrid functionals by calibration of exchange-energy densities

A new approach for the calibration of (semi-)local and exact exchange-energy densities in the context of local hybrid functionals is reported. The calibration functions are derived from only the electron density and its spatial derivatives, avoiding spatial derivatives of the exact-exchange energy density or other computationally unfavorable contributions. The calibration functions fulfill the seven more important out of nine known exact constraints. It is shown that calibration improves substantially the definition of a non-dynamical correlation energy term for generalized gradient approximation (GGA)-based local hybrids. Moreover, gauge artifacts in the potential-energy curves of noble-gas dimers may be corrected by calibration. The developed calibration functions are then evaluated for a large range of energy-related properties (atomization energies, reaction barriers, ionization potentials, electron affinities, and total atomic energies) of three sets of local hybrids, using a simple one-parameter local-mixing. The functionals are based on (a) local spin-density approximation (LSDA) or (b) Perdew-Burke-Ernzerhof (PBE) exchange and correlation, and on (c) Becke-88 (B88) exchange and Lee-Yang-Parr (LYP) correlation. While the uncalibrated GGA-based functionals usually provide very poor thermochemical data, calibration allows a dramatic improvement, accompanied by only a small deterioration of reaction barriers. In particular, an optimized BLYP-based local-hybrid functional has been found that is a substantial improvement over the underlying global hybrids, as well as over previously reported LSDA-based local hybrids. It is expected that the present calibration approach will pave the way towards new generations of more accurate hyper-GGA functionals based on a local mixing of exchange-energy densities.

37 INORGANIC, ORGANIC, PHYSICAL, AND ANALYTICAL CH↗

Development of two-band infrared radiometer for irradiance calibration of target simulators

A detector-based spectral radiometer has been developed for the calibration of target simulator. Unlike the conventional spectral irradiance calibration method based on radiance and irradiance, the new radiometer is calibrated using image-space temperature based method. The image-space temperature based method improves the reproducibility in the calibration of radiometer and reduces the uncertainties existing in the conventional calibration methods. The calibrated radiometer is then used to establish the irradiance transfer standard for the target simulator. With the designed radiometer in this paper, a highly accurate irradiance calibration for target simulators of wavelength from 2.05 to 2.55 μm and from 3.7 to 4.8 μm can be performed with an expanded uncertainty (k = 2) of calibration of 2.18%. Last but not least, the infrared radiation of the target simulator was measured by the infrared radiometer, the effectiveness and capability of which are verified through measurement of temperature and irradiance and a comparison with the thermal imaging camera.

46 INSTRUMENTATION RELATED TO NUCLEAR SCIENCE AND ↗

LONG-TERM CALIBRATION STABILITY OF A RADIO ASTRONOMICAL PHASED ARRAY FEED

There are many challenges associated with the implementation of a phased array feed for radio astronomy applications. Among these is the need to have an adequate set of calibration measurements so that reliable beamformers can be computed. Changes in the operating environment and temporal gain drift in the electronics contribute to calibration drift, which affects the beamformer performance. We will show that calibration measurements are relatively stable over a 5 day period and may remain so for up to 70 days or longer. We have incorporated the use of a calibration update system that has the potential to refresh a set of old calibrators, specifically correcting for electronic gain drift. However, the long-term variations that are present with fresh, current calibrators are greater than the degradation due to using an old calibration set, suggesting that, at this time, there is not a need for sophisticated calibration update systems or algorithms.

79 ASTRONOMY AND ASTROPHYSICS↗

IMPACT OF CHANDRA CALIBRATION UNCERTAINTIES ON GALAXY CLUSTER TEMPERATURES: APPLICATION TO THE HUBBLE CONSTANT

We perform a uniform, systematic X-ray spectroscopic analysis of a sample of 38 galaxy clusters with three different Chandra calibrations. The temperatures change systematically between calibrations. Cluster temperatures change on average by roughly {approx}6% for the smallest changes and roughly {approx}13% for the more extreme changes between calibrations. We explore the effects of the Chandra calibration on cluster spectral properties and the implications on Sunyaev-Zel'dovich effect (SZE) and X-ray determinations of the Hubble constant. The Hubble parameter changes by +10% and -13% between the current calibration and two previous Chandra calibrations, indicating that changes in the cluster temperature basically explain the entire change in H{sub 0}. Although this work focuses on the difference in spectral properties and resultant Hubble parameters between the calibrations, it is intriguing to note that the newer calibrations favor a lower value of the Hubble constant, H{sub 0} {approx} 60 km s{sup -1} Mpc{sup -1}, typical of results from SZE/X-ray distances. Both galaxy clusters themselves and the details of the instruments must be known precisely to enable reliable precision cosmology with clusters, which will be feasible with combined efforts from ongoing observations and planned missions and observatories covering a wide range of wavelengths.

79 ASTRONOMY AND ASTROPHYSICS↗

UNDERFLIGHT CALIBRATION OF SOHO/CDS AND HINODE/EIS WITH EUNIS-07

Flights of Goddard Space Flight Center's Extreme Ultraviolet Normal Incidence Spectrograph (EUNIS) sounding rocket in 2006 and 2007 provided updated radiometric calibrations for Solar and Heliospheric Observatory/Coronal Diagnostic Spectrometer (SOHO/CDS) and Hinode/Extreme Ultraviolet Imaging Spectrometer (Hinode/EIS). EUNIS carried two independent imaging spectrographs covering wavebands of 300-370 A in first order and 170-205 A in second order. After each flight, end-to-end radiometric calibrations of the rocket payload were carried out in the same facility used for pre-launch calibrations of CDS and EIS. During the 2007 flight, EUNIS, SOHO/CDS, and Hinode/EIS observed the same solar locations, allowing the EUNIS calibrations to be directly applied to both CDS and EIS. The measured CDS NIS 1 line intensities calibrated with the standard (version 4) responsivities with the standard long-term corrections are found to be too low by a factor of 1.5 due to the decrease in responsivity. The EIS calibration update is performed in two ways. One uses the direct calibration transfer of the calibrated EUNIS-07 short wavelength (SW) channel. The other uses the insensitive line pairs, in which one member was observed by the EUNIS-07 long wavelength (LW) channel and the other by EIS in either the LW or SW waveband. Measurements from both methods are in good agreement, and confirm (within the measurement uncertainties) the EIS responsivity measured directly before the instrument's launch. The measurements also suggest that the EIS responsivity decreased by a factor of about 1.2 after the first year of operation (although the size of the measurement uncertainties is comparable to this decrease). The shape of the EIS SW response curve obtained by EUNIS-07 is consistent with the one measured in laboratory prior to launch. The absolute value of the quiet-Sun He II 304 A intensity measured by EUNIS-07 is consistent with the radiance measured by CDS NIS in quiet regions near the disk center and the solar minimum irradiance recently obtained by CDS NIS and the Solar Dynamics Observatory/Extreme Ultraviolet Variability Experiment.

46 INSTRUMENTATION RELATED TO NUCLEAR SCIENCE AND ↗

Method to calibrate fission chambers in Campbelling mode

Fission chambers are neutron detectors which are widely used to instrument experimental reactors such as material testing reactors or zero power reactors. In the presence of a high level mixed gamma and neutron flux, fission chambers can be operated in Campbelling mode (also known as 'fluctuation mode' or 'mean square voltage mode') to provide reliable and precise neutron related measurements. Fission chamber calibration in Campbelling mode (in terms of neutron flux) is usually done empirically using a calibrated reference detector. A major drawback of this method is that calibration measurements have to be performed in a neutron environment very similar to the one in which the calibrated detector will be used afterwards. What we propose here is a different approach based on characterizing the fission chamber response in terms of fission rate. This way, the detector calibration coefficient is independent from the neutron spectrum and can be determined prior to the experiment. The fissile deposit response to the neutron spectrum can then be assessed independently by other means (experimental or numerical). In this paper, the response of CEA made miniature fission chambers in Campbelling mode is studied. We use a theoretical model of the signal to calculate the calibration coefficient. Input parameters of the model come from statistical distribution of individual pulses. Supporting measurements have been made in the CEA Cadarache zero power reactor MINERVE and results are compared to an empirical Campbelling mode calibration. The tested fission chamber calibration coefficient is about 2 10{sup -26} A{sup 2}/Hz/(c/s). Both numerical and empirical methods give consistent results, however a deviation of about 15 % was observed. (authors)

21 SPECIFIC NUCLEAR REACTORS AND ASSOCIATED PLANTS↗

Method to calibrate fission chambers in Campbelling mode

Fission chambers are neutron detectors which are widely used to instrument experimental reactors such as material testing reactors or zero power reactors. In the presence of a high level mixed gamma and neutron flux, fission chambers can be operated in Campbelling mode (also known as 'fluctuation mode' or 'mean square voltage mode') to provide reliable and precise neutron related measurements. Fission chamber calibration in Campbelling mode (in terms of neutron flux) is usually done empirically using a calibrated reference detector. A major drawback of this method is that calibration measurements have to be performed in a neutron environment very similar to the one in which the calibrated detector will be used afterwards. What is proposed here is a different approach based on characterizing the fission chamber response in terms of fission rate. This way, the detector calibration coefficient is independent from the neutron spectrum and can be determined prior to the experiment. The fissile deposit response to the neutron spectrum can then be assessed independently by other means (experimental or numerical). In this paper, the response of CEA-made miniature fission chambers in Campbelling mode is studied. A theoretical model of the signal is used to calculate the calibration coefficient. The model's input parameters come from statistical distribution of individual pulses. Supporting measurements were made in the CEA Cadarache zero power reactor MINERVE and results are compared to an empirical Campbelling mode calibration. The tested fission chamber calibration coefficient is roughly 2*10{sup -26} A{sup 2}/Hz/(c/s). Both numerical and empirical methods give consistent results, however a deviation of about 15% was observed. (authors)

21 SPECIFIC NUCLEAR REACTORS AND ASSOCIATED PLANTS↗

Empirical dual energy calibration (EDEC) for cone-beam computed tomography

Material-selective imaging using dual energy CT (DECT) relies heavily on well-calibrated material decomposition functions. These require the precise knowledge of the detected x-ray spectra, and even if they are exactly known the reliability of DECT will suffer from scattered radiation. We propose an empirical method to determine the proper decomposition function. In contrast to other decomposition algorithms our empirical dual energy calibration (EDEC) technique requires neither knowledge of the spectra nor of the attenuation coefficients. The desired material-selective raw data p{sub 1} and p{sub 2} are obtained as functions of the measured attenuation data q{sub 1} and q{sub 2} (one DECT scan=two raw data sets) by passing them through a polynomial function. The polynomial's coefficients are determined using a general least squares fit based on thresholded images of a calibration phantom. The calibration phantom's dimension should be of the same order of magnitude as the test object, but other than that no assumptions on its exact size or positioning are made. Once the decomposition coefficients are determined DECT raw data can be decomposed by simply passing them through the polynomial. To demonstrate EDEC simulations of an oval CTDI phantom, a lung phantom, a thorax phantom and a mouse phantom were carried out. The method was further verified by measuring a physical mouse phantom, a half-and-half-cylinder phantom and a Yin-Yang phantom with a dedicated in vivo dual source micro-CT scanner. The raw data were decomposed into their components, reconstructed, and the pixel values obtained were compared to the theoretical values. The determination of the calibration coefficients with EDEC is very robust and depends only slightly on the type of calibration phantom used. The images of the test phantoms (simulations and measurements) show a nearly perfect agreement with the theoretical {mu} values and density values. Since EDEC is an empirical technique it inherently compensates for scatter components. The empirical dual energy calibration technique is a pragmatic, simple, and reliable calibration approach that produces highly quantitative DECT images.

62 RADIOLOGY AND NUCLEAR MEDICINE↗

Calibration of the Gamma Knife using a new phantom following the AAPM TG51 and TG21 protocols

Purpose: To compare calibration of the Leksell Gamma Knife according to the American Association of Physicists in Medicine Task Groups 21 and 51 protocols. A new phantom was fabricated for this purpose. Its design, physical properties, and composition are described. Materials and methods: The Gamma Knife TG-51 calibration phantom is designed to be filled with water and support an ionization chamber positioned at its center. The phantom is thimble-shaped, with a 2 mm plastic wall to contain water. The phantom and chamber assembly was mounted in a LeksellTM stereotactic frame. The location of the chamber's sensitive volume was determined using computed tomography. The chamber-phantom assembly was attached to the 18 mm helmet in the Gamma Knife by the stereotactic frame. The phantom's geometry allowed radiation beams from each of the 201 Gamma Knife cobalt-60 sources to converge after an 8 cm path to the ionization chamber's sensitive volume. This is similar to the arrangement by which one calibrates the Gamma Knife using the manufacturer-supplied polystyrene phantom. Results: The phantom was attached to the Gamma Knife so that the ionization chamber was reproducibly positioned at the convergence of the radiation beams. Because of the phantom's design, the phantom could be affixed to either trunnions or the automatic patient positioning system, once mounted in the LeksellTM stereotectic frame. Comparisons using different phantoms and protocols resulted in the following calibration ratios for TG-21 in the polystyrene sphere phantom, TG-21 in the water phantom, and TG-51 in the water phantom, respectively: 1.000, 1.008, 0.986, when corrected for transmission through the plastic water reservoir wall and using the same ionization chamber. Transmission measurements using a 1 cm thickness of the same material in the Co-60 beam determined that the phantom's 2 mm plastic wall resulted in a reduction in the measured the output by 0.5%. Conclusions: Calibration of the Gamma Knife can be performed in liquid water using the AAPM TG-51 protocol and this new phantom, thereby eliminating uncertainties with respect to the composition of the manufacturer's phantom. Perturbation of calibration measurements by nonwater materials was characterized and could be corrected. Calibration values for the Gamma Knife that were obtained using the three methods for our phantoms agree to within 1.4%. TG21 and TG51 calibration of the Gamma Knife using the water phantom agreed to within 2.2%.

62 RADIOLOGY AND NUCLEAR MEDICINE↗