Engineering Papers⌕ Search

SEARCH · Engineering Papers

Results for “analytical performance models”

Search indexed NASA NTRS and DOE OSTI research on propulsion, heat transfer, battery materials and energy systems. Follow report and document links to the original sources.

Quote a phrase for an exact phrase match. Source license links do not imply unrestricted reuse.

At least 433 records · Page 24

Methylmercury and Ethylmercury Analytical Performance in SRR Samples Measured by SRNL and Eurofins Frontier Global Sciences

Existing models and simulants of tank disposition media at the Savannah River Site (SRS) have presumed the presence of high concentrations of inorganic mercury. However, quarterly Tank 50 analyses have shown that mercury is present as organomercurial species at concentrations that may present challenges to its remediation and disposition and may challenge the Waste Acceptance Criteria (WAC) for Saltstone. Todate, methylmercury analyses for Savannah River Remediation (SRR) have been performed at an off-site laboratory by Eurofins Frontier Global Sciences (FGS) in Bothell, WA. Savannah River Remediation requested the development of methylmercury and ethylmercury determination capabilities at the Savannah River National Laboratory (SRNL) to support the Liquid Waste Operations at SRS. As part of that method development, SRR requested that SRNL Analytical Development (AD) compare their results with those obtained from their outside contract laboratory, Eurofins FGS. This document reports on this method development work as well as the comparative analyses conducted between the two laboratories. A series of optimization and validation experiments has been performed at SRNL, which has resulted in the development of on-site methylmercury and ethylmercury speciation capabilities using purge and trap (P&T) gas chromatography (GC) coupled with thermal desorption (TD) cold vapor – atomic fluorescence spectroscopy (CVAFS). Speciation has been achieved for both species, with a methylmercury method reporting limit (MRL) value of 1.13 pg and an overall uncertainty (1σ) of 5.1%. An ethylmercury MRL of 11.5 pg and an overall uncertainty (1σ) of 4.8% were obtained. These analytical parameters compare favorably with Eurofins FGS, which demonstrates uncertainties (1σ) for methylmercury and ethylmercury of 13% and 9.1%, respectively. Results obtained by SRNL from the routine analysis of Tanks 21, 40, 50, and 51 samples have provided statistically indistinguishable results compared with Eurofins FGS. Based upon the work performed by SRNL-AD and the data currently available, the following recommendations can be made: Further work should be performed to determine a “best practices” for sample holding time prior to analysis (both preserved and non-preserved samples), as well as any detrimental effects sample age may have on data quality. Analysis of ethylmercury is only recommended for tank samples that are reasonably expected to have significant quantities of ethylmercury, such as from the DWPF SMECT. Trace levels of ethylmercury in the presence of large quantities of methylmercury can be difficult or impossible to quantify. SRNL-AD development of methods for total mercury, purgeable mercury (which includes Hg(0) and dimethylmercury), inorganic mercury (Hg(I) and Hg(II)), dissolved mercury, and particulate mercury are underway and will be reported upon separately.

12 MANAGEMENT OF RADIOACTIVE AND NON-RADIOACTIVE W↗

Initialization and Simulation of Three-Dimensional Aircraft Wake Vortices

This paper studies the effects of axial velocity profiles on vortex decay, in order to properly initialize and simulate three-dimensional wake vortex flow. Analytical relationships are obtained based on a single vortex model and computational simulations are performed for a rather practical vortex wake, which show that the single vortex analytical relations can still be applicable at certain streamwise sections of three-dimensional wake vortices.

Ash, Robert L.↗

Electric-field-induced plasmon in AA-stacked bilayer graphene

The collective excitations in AA-stacked bilayer graphene for a perpendicular electric field are investigated analytically within the tight-binding model and the random-phase approximation. Such a field destroys the uniform probability distribution of the four sublattices. This drives a symmetry breaking between the intralayer and interlayer polarization intensities from the intrapair band excitations. A field-induced acoustic plasmon thus emerges in addition to the strongly field-tunable intrinsic acoustic and optical plasmons. At long wavelengths, the three modes show different dispersions and field dependence. The definite physical mechanism of the electrically inducible and tunable mode can be expected to also be present in other AA-stacked few-layer graphenes. -- Highlights: •The analytical derivations are performed by the tight-binding model. •An electric field drives the non-uniformity of the charge distribution. •A symmetry breaking between the intralayer and interlayer polarizations is illustrated. •An extra plasmon emerges besides two intrinsic modes in AA-stacked bilayer graphene. •The mechanism of a field-induced mode is present in AA-stacked few-layer graphenes.

71 CLASSICAL AND QUANTUM MECHANICS, GENERAL PHYSIC↗

Selective consolidation of learning and memory via recall-gated plasticity

In a variety of species and behavioral contexts, learning and memory formation recruits two neural systems, with initial plasticity in one system being consolidated into the other over time. Moreover, consolidation is known to be selective; that is, some experiences are more likely to be consolidated into long-term memory than others. Here, we propose and analyze a model that captures common computational principles underlying such phenomena. The key component of this model is a mechanism by which a long-term learning and memory system prioritizes the storage of synaptic changes that are consistent with prior updates to the short-term system. This mechanism, which we refer to as recall-gated consolidation, has the effect of shielding long-term memory from spurious synaptic changes, enabling it to focus on reliable signals in the environment. We describe neural circuit implementations of this model for different types of learning problems, including supervised learning, reinforcement learning, and autoassociative memory storage. These implementations involve synaptic plasticity rules modulated by factors such as prediction accuracy, decision confidence, or familiarity. We then develop an analytical theory of the learning and memory performance of the model, in comparison to alternatives relying only on synapse-local consolidation mechanisms. We find that recall-gated consolidation provides significant advantages, substantially amplifying the signal-to-noise ratio with which memories can be stored in noisy environments. We show that recall-gated consolidation gives rise to a number of phenomena that are present in behavioral learning paradigms, including spaced learning effects, task-dependent rates of consolidation, and differing neural representations in short- and long-term pathways.

59 BASIC BIOLOGICAL SCIENCES↗

Selective consolidation of learning and memory via recall-gated plasticity

In a variety of species and behavioral contexts, learning and memory formation recruits two neural systems, with initial plasticity in one system being consolidated into the other over time. Moreover, consolidation is known to be selective; that is, some experiences are more likely to be consolidated into long-term memory than others. Here, we propose and analyze a model that captures common computational principles underlying such phenomena. The key component of this model is a mechanism by which a long-term learning and memory system prioritizes the storage of synaptic changes that are consistent with prior updates to the short-term system. This mechanism, which we refer to as recall-gated consolidation, has the effect of shielding long-term memory from spurious synaptic changes, enabling it to focus on reliable signals in the environment. We describe neural circuit implementations of this model for different types of learning problems, including supervised learning, reinforcement learning, and autoassociative memory storage. These implementations involve synaptic plasticity rules modulated by factors such as prediction accuracy, decision confidence, or familiarity. We then develop an analytical theory of the learning and memory performance of the model, in comparison to alternatives relying only on synapse-local consolidation mechanisms. We find that recall-gated consolidation provides significant advantages, substantially amplifying the signal-to-noise ratio with which memories can be stored in noisy environments. We show that recall-gated consolidation gives rise to a number of phenomena that are present in behavioral learning paradigms, including spaced learning effects, task-dependent rates of consolidation, and differing neural representations in short- and long-term pathways.

Lindsey, Jack W. (ORCID:0000000309307327)↗

Design and performance of optimal detectors for guided wave structural health monitoring

Ultrasonic guided wave measurements in a long term structural health monitoring system are affected by measurement noise, environmental conditions, transducer aging and malfunction. This results in measurement variability which affects detection performance, especially in complex structures where baseline data comparison is required. This paper derives the optimal detector structure, within the framework of detection theory, where a guided wave signal at the sensor is represented by a single feature value that can be used for comparison with a threshold. Three different types of detectors are derived depending on the underlying structure’s complexity: (i) Simple structures where defect reflections can be identified without the need for baseline data; (ii) Simple structures that require baseline data due to overlap of defect scatter with scatter from structural features; (iii) Complex structure with dense structural features that require baseline data. The detectors are derived by modeling the effects of variabilities and uncertainties as random processes. Analytical solutions for the performance of detectors in terms of the probability of detection and false alarm are derived. A finite element model is used to generate guided wave signals and the performance results of a Monte-Carlo simulation are compared with the theoretical performance. initial results demonstrate that the problems of signal complexity and environmental variability can in fact be exploited to improve detection performance.

60 APPLIED LIFE SCIENCES↗

Radio frequency verification tasks related to a multiple aperture reflector system

The establishment of analytical methods for predicting the electromagnetic performance of multiple offset fed apertures for multiple beam large space antenna systems is highlighted. The development of experimental modeling techniques for verifying the analytical methods used in predicting the effects of surface roughness (pillows), scattering, and aperture coupling on RF performance is discussed.

Campbell, T. G.↗

Coupling Big Data Analytics and Reactive Transport Modeling for Cost-effective Groundwater Monitoring - 17163

This study presents an innovative approach for sustainable and cost-effective groundwater monitoring. This approach takes advantage of recent advances in various technologies: (1) in situ autonomous sensors, (2) big data analytics, and (3) parallel high-performance computing for flow and reactive transport modeling. In situ sensors are used to periodically measure the key variables (such as pH, redox potential, electrical conductivity, and groundwater level), which control contaminant mobility and the plume spatial and temporal distribution. Based on a limited number of groundwater sampling, the data analytics methods-data mining and machine learning-allow us to identify and quantify the correlations between the in situ-measured variables and contaminant concentrations, and also to detect significant changes associated with the plume mobility. In addition, a state-of-the-art parallel numerical flow and reactive transport simulator Amanzi, and uncertainty quantification software Agni are used to provide an improved physical and mechanistic understanding of the contaminated groundwater system behavior, and to predict the long-term plume distribution for optimizing and adapting the monitoring strategy. Amanzi and Agni were developed as part of the Advanced Simulation Capability for Environmental Management (ASCEM) program of the DOE Office of Environmental Management. Such modeling is critical, particularly, for assessing the impact of climate change and associated hydrological shifts. The developed approach is expected to significantly reduce the groundwater sampling frequency and associated cost. In addition, the real-time information on plume mobility serves as an early warning system, improving the resiliency of contaminated or potentially contaminated sites. We demonstrate this approach using as an example the Savannah River Site (SRS) F-Area, where groundwater is contaminated by various radionuclides, including uranium, tritium and technetium. (authors)

12 MANAGEMENT OF RADIOACTIVE AND NON-RADIOACTIVE W↗

The NREL Sensor Laboratory Detection of Hydrogen Emissions

The development of a functional hydrogen detection system is a multifaceted process that integrates hardware, deployments strategies, and analytics which can be supported by the NREL Sensor Laboratory: 1. Support of the design, validation and optimization of sensing prototypes; 2. Guide optimized sensing element development, including control electronics; 3. Laboratory testing to validate/optimize metrological performance (measurement range, detection limit, etc.); 4. Provide test sites for field deployments representative of real-world scenarios with controlled hydrogen releases; 5. Develop sensor placement and operation guidance; 6. Provide guidance on electronics to accommodate facility integration; 7. Electrical safety designs to allow for operation within restricted zones; 8. Integration into facility monitoring and control systems; 9. Guide incorporation of cyber security elements to protect facilities from malicious attacks; 10. Modeling and application of advanced analytics to detect and quantify emissions; 11. Higher Order dispersion models to guide sensor placement for reliable detection; 12. Advanced analytics for improved metrological performances, and to inform inverse modeling; 13. Market support and commercialization (national and international markets); 14. Commercial deployments in H2@SCALE markets (e.g., HUBs and other large-scale hydrogen markets); and 15. Leverage off international collaborations/partnerships (e.g., NREL is on the advisory board for the European initiative "pre-Normative Research on Hydrogen Releases Assessment"-NHyRA).

08 HYDROGEN↗

Extraction of the proton radius from electron-proton scattering data

We perform a new analysis of electron-proton scattering data to determine the proton electric and magnetic radii, enforcing model-independent constraints from form factor analyticity. A wide-ranging study of possible systematic effects is performed. An improved analysis is developed that rebins data taken at identical kinematic settings and avoids a scaling assumption of systematic errors with statistical errors. Employing standard models for radiative corrections, our improved analysis of the 2010 Mainz A1 Collaboration data yields a proton electric radius r E = 0.895(20) fm and magnetic radius r M = 0.776(38) fm. A similar analysis applied to world data (excluding Mainz data) implies r E = 0.916(24) fm and r M = 0.914(35) fm. The Mainz and world values of the charge radius are consistent, and a simple combination yields a value r E = 0.904(15) fm that is 4σ larger than the CREMA Collaboration muonic hydrogen determination. The Mainz and world values of the magnetic radius differ by 2.7σ, and a simple average yields r M = 0.851(26) fm. As a result, the circumstances under which published muonic hydrogen and electron scattering data could be reconciled are discussed, including a possible deficiency in the standard radiative correction model which requires further analysis.

72 PHYSICS OF ELEMENTARY PARTICLES AND FIELDS↗

Comparing 3D and 2D CFD for Mars Helicopter Ingenuity Rotor Performance Prediction

Single and coaxial rotor performance simulations for the Mars Helicopter Ingenuity rotor are performed for representative Mars atmospheric conditions. Analyses are presented using both a high-fidelity 3D CFD model of the rotor and 2D CFD models of the airfoil sections for comprehensive analyses that use CAMRADII (Comprehensive Analytical Model of Rotorcraft Aerodynamics and Dynamics). When available, the airfoil performance calculations are generated using a numerical approach identical to that used in the high-fidelity 3D model, allowing for a direct comparison between the approaches. Experimental data from a validation campaign to explore higher thrust from an Ingenuity rotor is provided to substantiate a discussion on the simulation fidelity required for both coaxial and single rotor performance predictions. The data is in support of the Sample Recovery Helicopter (SRH) element that serves as the primary backup for tube retrieval as part of the Mars Sample Return (MSR) Campaign. Insights on modeling turbulence at low Reynolds numbers and its influence on the rotor figure of merit are discussed. Key rotor performance metrics are compared. A detailed investigation into differences between 2D and 3D rotor performance predictions, spanwise loading, and rotor stall behavior is included.

Mars Helicopter↗

Higher order finite element analysis of thick composite laminates

A higher order, sub-parametric, laminated, 3D solid finite element was used for the analysis of very thick laminated composite plates. The geometry of this element is defined by four nodes in the X-Y plane which define a prism of material through the thickness of the laminate. There are twenty-four degrees of freedom at each node; translations at the upper and lower surfaces of the laminate in each of the three coordinate directions, and the derivatives of these translations with respect to each coordinate. This choice of degrees of freedom leads to displacement and strain compatibility at the corners. Stacking sequence effects are accounted for by explicitly integrating the strain energy density through the thickness of the element. The laminated solid element was combined with a gap-contact element to analyze thick laminated composite lugs loaded through flexible pins. The resulting model accounts for pin bending effects that produce non-uniform bearing stresses through the thickness of the lug. A thick composite lug experimental test program was performed, and provided data that was used to validate the analytical model. Two lug geometries and three stacking sequences were tested.

Goering, J.↗

Mass Transport within Soils

Contaminants in soil can impact human health and the environment through a complex web of interactions. Soils exist where the atmosphere, hydrosphere, geosphere, and biosphere converge. Soil is the thin outer zone of the earth's crust that supports rooted plants and is the product of climate and living organisms acting on rock. A true soil is a mixture of air, water, mineral, and organic components. The relative proportions of these components determine the value of the soil for agricultural and for other human uses. These proportions also determine, to a large extent, how a substance added to soil is transported and/or transformed within the soil (Spositio, 2004). In mass-balance models, soil compartments play a major role, functioning both as reservoirs and as the principal media for transport among air, vegetation, surface water, deeper soil, and ground water (Mackay, 2001). Quantifying the mass transport of chemicals within soil and between soil and atmosphere is important for understanding the role soil plays in controlling fate, transport, and exposure to multimedia pollutants. Soils are characteristically heterogeneous. A trench dug into soil typically reveals several horizontal layers having different colors and textures. As illustrated in Figure 1, these multiple layers are often divided into three major horizons: (1) the A horizon, which encompasses the root zone and contains a high concentration of organic matter; (2) the B horizon, which is unsaturated, lies below the roots of most plants, and contains a much lower organic carbon content; and (3) the C horizon, which is the unsaturated zone of weathered parent rock consisting of bedrock, alluvial material, glacial material, and/or soil of an earlier geological period. Below these three horizons lies the saturated zone - a zone that encompasses the area below ground surface in which all interconnected openings within the geologic media are completely filled with water. Similarly to the unsaturated zone with three major horizons, the saturated zone can be further divided into other zones based on hydraulic and geologic conditions. Wetland soils are a special and important class in which near-saturation conditions exist most of the time. When a contaminant is added to or formed in a soil column, there are several mechanisms by which it can be dispersed, transported out of the soil column to other parts of the environment, destroyed, or transformed into some other species. Thus, to evaluate or manage any contaminant introduced to the soil column, one must determine whether and how that substance will (1) remain or accumulate within the soil column, (2) be transported by dispersion or advection within the soil column, (3) be physically, chemically, or biologically transformed within the soil (i.e., by hydrolysis, oxidation, etc.), or (4) be transported out of the soil column to another part of the environment through a cross-media transfer (i.e., volatilization, runoff, ground water infiltration, etc.). These competing processes impact the fate of physical, chemical, or biological contaminants found in soils. In order to capture these mechanisms in mass transfer models, we must develop mass-transfer coefficients (MTCs) specific to soil layers. That is the goal of this chapter. The reader is referred to other chapters in this Handbook that address related transport processes, namely Chapter 13 on bioturbation, Chapter 15 on transport in near-surface geological formations, and Chapter 17 on soil resuspention. This chapter addresses the following issues: the nature of soil pollution, composition of soil, transport processes and transport parameters in soil, transformation processes in soil, mass-balance models, and MTCs in soils. We show that to address vertical heterogeneity in soils in is necessary to define a characteristic scaling depth and use this to establish process-based expressions for soil MTCs. The scaling depth in soil and the corresponding MTCs depend strongly on (1) the composition of the soil and physical state of the soil, (2) the chemical and physical properties of the substance of interest, and (3) transformation rates in soil. Our particular focus is on approaches for constructing soil-transport algorithms and soil-transport parameters for incorporation within multimedia fate models. We show how MTC's can be developed to construct a simple two-compartment air-soil system. We then demonstrate how a multi-layer-box-model approach for soil-mass balance converges to the exact analytical solution for concentration and mass balance. Finally, we demonstrate and evaluate the performance of the algorithms in a model with applications to the specimen chemicals benzene, hexachlorobenzene, lindane gammahexachlorocyclohexane, benzo(a)pyrene, nickel, and copper.

54 ENVIRONMENTAL SCIENCES↗

Determination of origin and intended use of plutonium metal using nuclear forensic techniques

Nuclear forensics techniques, including micro-XRF, gamma spectrometry, trace elemental analysis and isotopic/chronometric characterization were used to interrogate two, potentially related plutonium metal foils. These samples were submitted for analysis with only limited production information, and a comprehensive suite of forensic analyses were performed. Resulting analytical data was paired with available reactor model and historical information to provide insight into the materials’ properties, origins, and likely intended uses. Both were super-grade plutonium, containing less than 3% 240 Pu, and age-dating suggested that most recent chemical purification occurred in 1948 and 1955 for the respective metals. Additional consideration of reactor modelling feedback and trace elemental observables indicate plausible U.S. reactor origin associated with the Hanford site production efforts. In conclusion, based on this investigation, the most likely intended use for these plutonium foils was 239 Pu fission foil targets for physics experiments, such as cross-section measurements, etc.

73 NUCLEAR PHYSICS AND RADIATION PHYSICS↗

OPENING ANGLES OF COLLAPSAR JETS

We investigate the jet propagation and breakout from the stellar progenitor for gamma-ray burst (GRB) collapsars by performing two-dimensional relativistic hydrodynamic simulations and analytical modeling. We find that the jet opening angle is given by θ{sub j} ∼ 1/5Γ{sub 0} and infer the initial Lorentz factor of the jet at the central engine, Γ{sub 0}, is a few for existing observations of θ{sub j}. The jet keeps the Lorentz factor low inside the star by converging cylindrically via collimation shocks under the cocoon pressure and accelerates at jet breakout before the free expansion to a hollow-cone structure. In this new picture, the GRB duration is determined by the sound crossing time of the cocoon, after which the opening angle widens, reducing the apparent luminosity. Some bursts violating the maximum opening angle θ{sub j,{sub max}} ∼ 1/5 ∼ 12° imply the existence of a baryon-rich sheath or a long-acting jet. We can explain the slopes in both Amati and Yonetoku spectral relations using an off-centered photosphere model, if we make only one assumption that the total jet luminosity is proportional to the initial Lorentz factor of the jet. We also numerically calibrate the pre-breakout model (Bromberg et al.) for later use.

79 ASTRONOMY AND ASTROPHYSICS↗

A modal approach to the numerical calculation of primordial non-Gaussianities

We propose a new method to numerically calculate higher-order correlation functions of primordial fluctuations generated from any early-universe scenario. Our key-starting point is the realization that the tree-level In-In formalism is intrinsically separable. This enables us to use modal techniques to efficiently calculate and represent non-Gaussian shapes in a separable form well suited to data analysis. We prove the feasibility and the accuracy of our method by applying it to simple single-field inflationary models in which analytical results are available, and we perform non-trivial consistency checks like the verification of the single field consistency relation. We also point out that the iε prescription is automatically taken into account in our method, preventing the need for ad-hoc tricks to implement it numerically.

79 ASTRONOMY AND ASTROPHYSICS↗

Analytic Neural Network Gaussian Process Enabled Chance-Constrained Voltage Regulation for Active Distribution Systems with PVs, Batteries and EVs

This paper proposes an analytic neural network Gaussian process (NNGP)-based chance-constrained real-time voltage regulation method for active distribution systems with photovoltaics (PVs), batteries, and electric vehicles (EVs). NNGP can utilize historical measurement data to achieve real-time probabilistic node voltage estimation through Bayesian inference. Then, NNGP is fully analytically embedded into the optimal power flow model to perform voltage regulation and adapt to various topological changes. The uncertainties of voltage estimations are easily considered via the chance constraint, and it has been shown that the adoption of this chance constraint can significantly improve the reliability of voltage regulation under various scenarios. The comparison results with other methods, carried out on a real 759-node distribution system located in western Colorado, U.S., show that the proposed method can achieve accurate voltage estimation across different topologies and reliably perform voltage regulation considering PVs, batteries, and EVs.

active distribution systems↗

MO-F-16A-02: Simulation of a Medical Linear Accelerator for Teaching Purposes

Purpose: Detailed functioning of linear accelerator physics is well known. Less well developed is the basic understanding of how the adjustment of the linear accelerator's electrical components affects the resulting radiation beam. Other than the text by Karzmark, there is very little literature devoted to the practical understanding of linear accelerator functionality targeted at the radiotherapy clinic level. The purpose of this work is to describe a simulation environment for medical linear accelerators with the purpose of teaching linear accelerator physics. Methods: Varian type lineacs were simulated. Klystron saturation and peak output were modelled analytically. The energy gain of an electron beam was modelled using load line expressions. The bending magnet was assumed to be a perfect solenoid whose pass through energy varied linearly with solenoid current. The dose rate calculated at depth in water was assumed to be a simple function of the target's beam current. The flattening filter was modelled as an attenuator with conical shape, and the time-averaged dose rate at a depth in water was determined by calculating kerma. Results: Fifteen analytical models were combined into a single model called SIMAC. Performance was verified systematically by adjusting typical linac control parameters. Increasing klystron pulse voltage increased dose rate to a peak, which then decreased as the beam energy was further increased due to the fixed pass through energy of the bending magnet. Increasing accelerator beam current leads to a higher dose per pulse. However, the energy of the electron beam decreases due to beam loading and so the dose rate eventually maximizes and the decreases as beam current was further increased. Conclusion: SIMAC can realistically simulate the functionality of a linear accelerator. It is expected to have value as a teaching tool for both medical physicists and linear accelerator service personnel.

43 PARTICLE ACCELERATORS↗