Engineering Papers⌕ Search

SEARCH · Engineering Papers

Results for “agreements”

Search indexed NASA NTRS and DOE OSTI research on propulsion, heat transfer, battery materials and energy systems. Follow report and document links to the original sources.

Quote a phrase for an exact phrase match. Source license links do not imply unrestricted reuse.

At least 433 records · Page 24

Development and validation of an automatic method to detect the latest contracting viable left ventricular segments to assist guide CRT therapy from gated SPECT myocardial perfusion imaging

Objectives: The purpose of this study is to use ECG-gated SPECT MPI to detect the latest contracting viable left ventricular (LV) segments to help guide the LV probe placement used in CRT therapy and to validate segment selection against the visual integration method by experts. Methods: For each patient, the resting ECG-gated SPECT MPI short-axis images were sampled in 3D to generate a polar map of the perfusion distribution used to determine LV myocardial viability, and to measure LV synchronicity using our phase analysis tool. In the visual integration method, two experts visually interpreted the LV viability and mechanical dyssynchrony from the short-axis images and polar maps of viability and phase, to determine the latest contracting viable segments using the 17-segment model. In the automatic method, the apical segments, septal segments, and segments with more than 50% scar were excluded as these are not candidates for CRT LV probe placement. Amongst the remaining viable segments, the segments, whose phase angles were within 10° of the latest phase angle (the most delayed contracting segment), were identified for potential CRT LV probe placement and ranked based on the phase angles of the segments. Both methods were tested in 36 pre-CRT patients who underwent ECG-gated SPECT MPI. The accuracy was determined as the percent agreement between the visual integration and automatic methods. The automatic method was performed by a second independent operator to evaluate the inter-operator processing reproducibility. Results: In all the 36 patients, the LV lead positions of the 1st choices recommended by the automatic and visual integration methods were in the same segments in 35 patients, which achieved an agreement rate of 97.2%. In the inter-operator reproducibility test, the LV lead positions of the 1st choices recommended by the two operators were in the same segments in 25 patients, and were in the adjacent segments in 7 patients, which achieved an overall agreement of 88.8%. Conclusions: An automatic method has been developed to detect the latest contracting viable LV segments to help guide the LV probe placement used in CRT therapy. The retrospective clinical study with 36 patients suggests that this method has high agreement against the visual integration method by experts and good inter-operator reproducibility. Consequently, this method is promising to be a clinical tool to recommend the CRT LV lead positions.

62 RADIOLOGY AND NUCLEAR MEDICINE↗

Load partitioning in Ai{sub 2}0{sub 3-}Al composites with three- dimensional periodic architecture.

Interpenetrating composites are created by infiltration of liquid aluminum into three-dimensional (3-D) periodic Al{sub 2}O{sub 3} preforms with simple tetragonal symmetry produced by direct-write assembly. Volume-averaged lattice strains in the Al{sub 2}O{sub 3} phase of the composite are measured by synchrotron X-ray diffraction for various uniaxial compression stresses up to -350MPa. Load transfer, found by diffraction to occur from the metal phase to the ceramic phase, is in general agreement with simple rule-of-mixture models and in better agreement with more complex, 3-D finite-element models that account for metal plasticity and details of the geometry of both phases. Spatially resolved diffraction measurements show variations in load transfer at two different positions within the composite.

43 PARTICLE ACCELERATORS↗

Oscillator strengths and transition probabilities from the Breit–Pauli R-matrix method: Ne IV

The atomic parameters–oscillator strengths, line strengths, radiative decay rates (A), and lifetimes–for fine structure transitions of electric dipole (E1) type for the astrophysically abundant ion Ne IV are presented. The results include 868 fine structure levels with n≤ 10, l≤ 9, and 1/2≤J≤ 19/2 of even and odd parities, and the corresponding 83,767 E1 transitions. The calculations were carried out using the relativistic Breit–Pauli R-matrix method in the close coupling approximation. The transitions have been identified spectroscopically using an algorithm based on quantum defect analysis and other criteria. The calculated energies agree with the 103 observed and identified energies to within 3% or better for most of the levels. Some larger differences are also noted. The A-values show good to fair agreement with the very limited number of available transitions in the table compiled by NIST, but show very good agreement with the latest published multi-configuration Hartree–Fock calculations. The present transitions should be useful for diagnostics as well as for precise and complete spectral modeling in the soft X-ray to infra-red regions of astrophysical and laboratory plasmas. -- Highlights: •The first application of BPRM method for accurate E1 transitions in Ne IV is reported. •Amount of atomic data (n going up to 10) is complete for most practical applications. •The calculated energies are in very good agreement with most observed levels. •Very good agreement of A-values and lifetimes with other relativistic calculations. •The results should provide precise nebular abundances, chemical evolution etc.

73 NUCLEAR PHYSICS AND RADIATION PHYSICS↗

SCALE capabilities for high temperature gas-cooled reactor analysis

The SCALE code system’s ability to address stochastic distributions of fuel particles within a graphite matrix has been revisited in both multigroup (MG) features and continuous-energy (CE) Monte Carlo methods. Furthermore, this paper describes current and emergent SCALE capabilities within the CSAS sequence to address double-heterogeneous systems and presents verification and validation studies of these methods and data. Good agreement was obtained for a high temperature gas-cooled reactor (HTGR) fuel pebble model between CSAS MG eigenvalue calculations and corresponding CE reference solutions. Code-to-code comparisons for this HTGR pebble model showed good agreement of CSAS-KENO and CSAS-Shift CE calculations and the Serpent and MCNP codes in terms of eigenvalues and reaction rate ratios. Validation studies based on two HTGR experiments resulted in good agreement between MG and CE results, as well as between experiment and calculation, although the level of agreement was significantly influenced by the applied ENDF/B nuclear data library.

22 GENERAL STUDIES OF NUCLEAR REACTORS↗

Soft costs and EVSE – Knowledge gaps as a barrier to successful projects

There has been a recent push to increase access to electric vehicle (EV) charging infrastructure. The National Electric Vehicle Infrastructure (NEVI) program, part of the Bipartisan Infrastructure Law (BIL) has made significant funding available for major charging infrastructure projects along state thruways, and many state and local incentives exist for EV owners to install chargers in their homes. However, deployment of these chargers has not kept up with demand, primarily due to issues in project planning, permitting processes, and unforeseen delays. This paper serves as a review of the current understanding of these and other non-hardware costs in EV charging infrastructure projects (collectively known as “soft costs”). We found that soft costs in EV charging infrastructure projects are not well understood. Specifically, there is little agreement on how soft costs should be categorized and tracked, and less agreement still on best practices for controlling these costs and lowering barriers to infrastructure deployment. A broader review of EV charging infrastructure cost analyses shows that these costs can have significant impacts on project outcomes. EV charging infrastructure projects may be able to examine the success of the solar industry in lowering soft costs, and a similar effort may lower project costs significantly. Further work on standardizing and collecting data on EV charging infrastructure costs is required to begin addressing and controlling these costs.

32 - ENERGY CONSERVATION, CONSUMPTION, AND UTILIZA↗

Elongation affinity, activation barrier, and stability of Aβ42 oligomers/fibrils in physiological saline

Amyloid-beta (Aβ) peptides, Aβ40 and the more neurotoxic Aβ42, have been the subject of many research efforts for Alzheimer's disease. In two recent independent investigations, the atomistic structure of Aβ42 fibril has been clearly established in the S-shaped conformation consisting of three β-sheets stabilized by salt bridges formed between the Lys28 sidechain and the C-terminus of Ala42. This structure distinctively differs from the long-known structure of Aβ40 in the β-hairpin shaped conformation consisting of two β-sheets. Recent in silico investigations based on all-atom models have reached closer agreement with the in vitro measurements of Aβ40 thermodynamics. In this study, we present an in silico investigation of Aβ42 thermodynamics. Using the established force field parameters in seven sets of all-atom simulations, we examined the stability of small Aβ42 oligomers in physiological saline. We computed the elongation affinity of the S-shaped Aβ42 fibril, reaching agreement with the experimental data. We also estimated the Arrhenius activation barrier along the elongation pathway (from the disordered conformation of a free Aβ42 peptide to its S-shaped conformation on a fibril) that amounts to about 16 kcal/mol, which is consistent with the experimental data. Based on these quantitative agreements, we conclude that aggregation of Aβ42 peptides into fibrils is thermodynamically slow without precipitation by extrinsic factors such as heparan sulfate proteoglycan and highlight the possibility to prevent Aβ42 aggregation by eliminating some precipitation factors or by increasing competitive agents to capture and transport free Aβ42 peptides from the cerebrospinal fluid. - Highlights: • Aβ42 fibril elongation affinity was computed with chemical accuracy, in agreement with in vitro data. • Small Aβ42 oligomers were found to be stable in physiological saline. • A long Aβ42 fibril-filament was shown to stabilize an Aβ dimer in its proximity.

60 APPLIED LIFE SCIENCES↗

A Comparison of In-Room Computerized Tomography Options for Detection of Fiducial Markers in Prostate Cancer Radiotherapy

Purpose: To compare volumetric in-room computed tomography (CT) and kilovoltage (kV) cone-beam CT (CBCT) to planar imaging with respect to their ability to localize fiducial markers (FMs) for radiotherapy of prostate cancer. Methods and Materials: Image guidance options from two linear accelerators were compared in terms of identifying the center of gravity (COG) of FMs from the isocenter: a Siemens Primatom, where the couch is rotated 180 degrees from the treatment isocenter to the in-room CT vs. electronic portal imaging (EPI); and a Varian OBI system, where kV CBCT, EPI, and planar kV radiographs were compared. In all, 387 image pairs (CBCT = 133; CT = 254) from 18 patients were analyzed. A clinical tolerance of 3 mm was predefined as the acceptable threshold for agreement. Results: COG location on in-room CT and EPI was in agreement 96.9%, 85.8%, and 89.0% of the time in the left-right (LR), superior-inferior (SI), and anterior-posterior (AP) directions, respectively, vs. 99.2%, 91.7%, and 93.2% for the CBCT and EPI analysis. The CBCT vs. kV radiographs were in agreement 100% (LR), 85.4% (SI), and 88.5% (AP), and EPI vs. kV radiographs were in agreement 100% (LR), 94.6% (SI), and 91.5% (AP) of the time. Conclusion: Identification of FMs on volumetric or planar images was found to be not equivalent ({+-}3 mm) using either linear accelerator. Intrafraction prostate motion, interpretation of FM location, and spatial properties of images are contributing factors. Although in-room CT has superior image quality, the process of realigning the treatment couch to acquire a CT introduces an error, highlighting the benefits of a single isocentric system.

62 RADIOLOGY AND NUCLEAR MEDICINE↗

Volumetric Modulation Arc Radiotherapy Compared With Static Gantry Intensity-Modulated Radiotherapy for Malignant Pleural Mesothelioma Tumor: A Feasibility Study

Purpose: A planning study was performed to evaluate RapidArc (RA), a volumetric modulated arc technique, on malignant pleural mesothelioma. The benchmark was conventional fixed-field intensity-modulated radiotherapy (IMRT). Methods and materials: The computed tomography data sets of 6 patients were included. The plans for IMRT with nine fixed beams were compared against double-modulated arcs with a single isocenter. All plans were optimized for 15-MV photon beams. The dose prescription was 54 Gy to the planning target volume. The planning objectives for the planning target volume were a minimal dose of >95% and maximal dose of <107%. For the organs at risk, the parameters were as follows: contralateral lung, percentage of volume receiving 5 Gy (V{sub 5Gy}) <60%, V{sub 20Gy} < 10%, mean <10.0 Gy; liver, V{sub 30Gy} <33%, mean <31 Gy; heart, V{sub 45Gy} <30%, V{sub 50Gy} <20%, dose received by 1% of the volume (D{sub 1%}) <60 Gy; contralateral kidney, V{sub 15Gy} <20%; spine, D{sub 1%} <45 Gy; esophagus, V{sub 55Gy} <30%; and spleen, V{sub 40Gy} <50%. The monitor units (MUs) and delivery time were scored to measure the treatment efficiency. The pretreatment portal dosimetry scored delivery to the calculation agreement with the Gamma Agreement Index. Results: RA and IMRT provided equivalent coverage and homogeneity. Both techniques fulfilled objectives on organs at risk with a tendency of RA to improve sparing. The conformity index was 1.9 {+-} 0.1 for RA and IMRT. The number of MU/2Gy was 734 {+-} 82 for RA and 2,195 {+-} 317 for IMRT. The planning vs. delivery agreement revealed a Gamma Agreement Index for IMRT of 96.0% {+-} 2.6% and for RA of 95.7% {+-} 1.5%. The treatment time was 3.7 {+-} 0.3min for RA and 13.4 {+-} 0.1min for IMRT. Conclusion: RA demonstrated compared with conventional IMRT, similar target coverage and better dose sparing to the organs at risks. The number of MUs and the time required to deliver a 2-Gy fraction were much lower for RA, allowing the possibility to incorporate this technique in the treatment options for mesothelioma patients.

62 RADIOLOGY AND NUCLEAR MEDICINE↗

Preclinical Assessment of Volumetric Modulated Arc Therapy for Total Marrow Irradiation

Purpose: A preclinical investigation was undertaken to explore a treatment technique for total marrow irradiation using RapidArc, a volumetric modulated arc technique. Materials and Methods: Computed tomography datasets of 5 patients were included. Plans with eight overlapping coaxial arcs were optimized for 6-MV photon beams. Dose prescription was 12 Gy in 2 Gy per fraction, normalized so that 100% isodose covered 85% of the planning target volume (PTV). The PTV consisted of the whole skeleton (including ribs and sternum), from the top of the skull to the medium distal third of the femurs. Planning objectives for organs at risk (OARs) were constrained to a median dose <6 to 7 Gy. OARs included brain, eyes, oral cavity, parotids, thyroid, lungs, heart, kidneys, liver, spleen, stomach, abdominal cavity, bladder, rectum, and genitals. Pretreatment quality assurance consisted of portal dosimetry comparisons, scoring the delivery to calculation agreement with the gamma agreement index. Results: The median total body volume in the study was 57 liters (range, 49-81 liters), for an average diameter of 47 cm (range, 46-53 cm) and a total length ranging from 95 to 112 cm. The median PTV volume was 6.8 liters (range, 5.8-10.8 liters). The mean dose to PTV was 109% (range, 107-112%). The global mean of median dose to all OARs was 4.9 Gy (range, 4.5-5.1 Gy over the 5 patients). The individual mean of median doses per organ ranged from 2.3 Gy (oral cavity) to 7.3 Gy (bowels cavity). Preclinical quality assurance resulted in a mean gamma agreement index of 94.3 {+-} 5.1%. The delivery time measured from quality assurance runs was 13 minutes. Conclusion: Sparing of normal tissues with adequate coverage of skeletal bones was shown to be feasible with RapidArc. Pretreatment quality assurance measurements confirmed the technical agreement between expected and actually delivered dose distributions, suggesting the possibility of incorporating this technique in the treatment options for patients.

62 RADIOLOGY AND NUCLEAR MEDICINE↗

Variation in the Gross Tumor Volume and Clinical Target Volume for Preoperative Radiotherapy of Primary Large High-Grade Soft Tissue Sarcoma of the Extremity Among RTOG Sarcoma Radiation Oncologists

Purpose: To evaluate variability in the definition of preoperative radiotherapy gross tumor volume (GTV) and clinical target volume (CTV) delineated by sarcoma radiation oncologists. Methods and Materials: Extremity sarcoma planning CT images along with the corresponding diagnostic MRI from two patients were distributed to 10 Radiation Therapy Oncology Group sarcoma radiation oncologists with instructions to define GTV and CTV using standardized guidelines. The CT data with contours were then returned for central analysis. Contours representing statistically corrected 95% (V95) and 100% (V100) agreement were computed for each structure. Results: For the GTV, the minimum, maximum, mean (SD) volumes (mL) were 674, 798, 752 {+-} 35 for the lower extremity case and 383, 543, 447 {+-} 46 for the upper extremity case. The volume (cc) of the union, V95 and V100 were 882, 761, and 752 for the lower, and 587, 461, and 455 for the upper extremity, respectively. The overall GTV agreement was judged to be almost perfect in both lower and upper extremity cases (kappa = 0.9 [p < 0.0001] and kappa = 0.86 [p < 0.0001]). For the CTV, the minimum, maximum, mean (SD) volumes (mL) were 1145, 1911, 1605 {+-} 211 for the lower extremity case and 637, 1246, 1006 {+-} 180 for the upper extremity case. The volume (cc) of the union, V95, and V100 were 2094, 1609, and 1593 for the lower, and 1533, 1020, and 965 for the upper extremity cases, respectively. The overall CTV agreement was judged to be almost perfect in the lower extremity case (kappa = 0.85 [p < 0.0001]) but only substantial in the upper extremity case (kappa = 0.77 [p < 0.0001]). Conclusions: Almost perfect agreement existed in the GTV of these two representative cases. Tshere was no significant disagreement in the CTV of the lower extremity, but variation in the CTV of upper extremity was seen, perhaps related to the positional differences between the planning CT and the diagnostic MRI.

62 RADIOLOGY AND NUCLEAR MEDICINE↗

Use of EORTC Target Definition Guidelines for Dose-Intensified Salvage Radiation Therapy for Recurrent Prostate Cancer: Results of the Quality Assurance Program of the Randomized Trial SAKK 09/10

Purpose: Different international target volume delineation guidelines exist and different treatment techniques are available for salvage radiation therapy (RT) for recurrent prostate cancer, but less is known regarding their respective applicability in clinical practice. Methods and Materials: A randomized phase III trial testing 64 Gy vs 70 Gy salvage RT was accompanied by an intense quality assurance program including a site-specific and study-specific questionnaire and a dummy run (DR). Target volume delineation was performed according to the European Organisation for the Research and Treatment of Cancer guidelines, and a DR-based treatment plan was established for 70 Gy. Major and minor protocol deviations were noted, interobserver agreement of delineated target contours was assessed, and dose-volume histogram (DVH) parameters of different treatment techniques were compared. Results: Thirty European centers participated, 43% of which were using 3-dimensional conformal RT (3D-CRT), with the remaining centers using intensity modulated RT (IMRT) or volumetric modulated arc technique (VMAT). The first submitted version of the DR contained major deviations in 21 of 30 (70%) centers, mostly caused by inappropriately defined or lack of prostate bed (PB). All but 5 centers completed the DR successfully with their second submitted version. The interobserver agreement of the PB was moderate and was improved by the DR review, as indicated by an increased κ value (0.59 vs 0.55), mean sensitivity (0.64 vs 0.58), volume of total agreement (3.9 vs 3.3 cm{sup 3}), and decrease in the union volume (79.3 vs 84.2 cm{sup 3}). Rectal and bladder wall DVH parameters of IMRT and VMAT vs 3D-CRT plans were not significantly different. Conclusions: The interobserver agreement of PB delineation was moderate but was improved by the DR. Major deviations could be identified for the majority of centers. The DR has improved the acquaintance of the participating centers with the trial protocol.

62 RADIOLOGY AND NUCLEAR MEDICINE↗

Interrater Reliability of the Categorization of Late Radiographic Changes After Lung Stereotactic Body Radiation Therapy

Purpose: Radiographic changes after lung stereotactic body radiation therapy (SBRT) have been categorized into 4 groups: modified conventional pattern (A), mass-like fibrosis; (B), scar-like fibrosis (C), and no evidence of increased density (D). The purpose of this study was to assess the interrater reliability of this categorization system in patients with early-stage non-small cell lung cancer (NSCLC). Methods and Materials: Seventy-seven patients were included in this study, all treated with SBRT for early-stage (T1/2) NSCLC at a single institution, with a minimum follow-up of 6 months. Six experienced clinicians familiar with post-SBRT radiographic changes scored the serial posttreatment CT images independently in a blinded fashion. The proportion of patients categorized as A, B, C, or D at each interval was determined. Krippendorff's alpha (KA), Multirater kappa (M-kappa), and Gwet's AC1 (AC1) scores were used to establish interrater reliability. A leave-one-out analysis was performed to demonstrate the variability among raters. Interrater agreement of the first and last 20 patients scored was calculated to explore whether a training effect existed. Results: The number of ratings ranged from 450 at 6 months to 84 at 48 months of follow-up. The proportion of patients in each category was as follows: A, 45%; B, 16%; C, 13%; and D, 26%. KA and M-kappa ranged from 0.17 to 0.34. AC1 measure range was 0.22 to 0.48. KA increased from 0.24 to 0.36 at 12 months with training. The percent agreement for pattern A peaked at 12 month with a 54% chance of having >50% raters in agreement and decreased over time, whereas that for patterns B and C increased over time to a maximum of 20% and 22%, respectively. Conclusion: This post-SBRT radiographic change categorization system has modest interrater agreement, and there is a suggestion of a training effect. Patterns of fibrosis evolve after SBRT and alternative categorization systems should be evaluated.

62 RADIOLOGY AND NUCLEAR MEDICINE↗

Low Interrater Reliability in Grading of Rectal Bleeding Using National Cancer Institute Common Toxicity Criteria and Radiation Therapy Oncology Group Toxicity Scales: A Survey of Radiation Oncologists

Purpose: To measure concordance among genitourinary radiation oncologists in using the National Cancer Institute Common Toxicity Criteria (NCI CTC) and Radiation Therapy Oncology Group (RTOG) grading scales to grade rectal bleeding. Methods and Materials: From June 2013 to January 2014, a Web-based survey was sent to 250 American and Canadian academic radiation oncologists who treat prostate cancer. Participants were provided 4 case vignettes in which patients received radiation therapy and developed rectal bleeding and were asked for management plans and to rate the bleeding according to NCI CTC v.4 and RTOG late toxicity grading (scales provided). In 2 cases, participants were also asked whether they would send the patient for colonoscopy. A multilevel, random intercept modeling approach was used to assess sources of variation (case, respondent) in toxicity grading to calculate the intraclass correlation coefficient (ICC). Agreement on a dichotomous grading scale (low grades 1-2 vs high grades 3-4) was also assessed, using the κ statistic for multiple respondents. Results: Seventy-two radiation oncologists (28%) completed the survey. Forty-seven (65%) reported having either written or been principal investigator on a study using these scales. Agreement between respondents was moderate (ICC 0.52, 95% confidence interval [CI] 0.47-0.58) when using NCI CTC and fair using the RTOG scale (ICC 0.28, 95% CI 0.20-0.40). Respondents who chose an invasive management were more likely to select a higher toxicity grade (P<.0001). Using the dichotomous scale, we observed moderate agreement (κ = 0.42, 95% CI 0.40-0.44) with the NCI CTC scale, but only slight agreement with the RTOG scale (κ = 0.19, 95% CI 0.17-0.21). Conclusion: Low interrater reliability was observed among radiation oncologists grading rectal bleeding using 2 common scales. Clearer definitions of late rectal bleeding toxicity should be constructed to reduce this variability and avoid ambiguity in both reporting and interpretation.

62 RADIOLOGY AND NUCLEAR MEDICINE↗

Simple Method to Estimate Mean Heart Dose From Hodgkin Lymphoma Radiation Therapy According to Simulation X-Rays

Purpose: To describe a new method to estimate the mean heart dose for Hodgkin lymphoma patients treated several decades ago, using delineation of the heart on radiation therapy simulation X-rays. Mean heart dose is an important predictor for late cardiovascular complications after Hodgkin lymphoma (HL) treatment. For patients treated before the era of computed tomography (CT)-based radiotherapy planning, retrospective estimation of radiation dose to the heart can be labor intensive. Methods and Materials: Patients for whom cardiac radiation doses had previously been estimated by reconstruction of individual treatments on representative CT data sets were selected at random from a case–control study of 5-year Hodgkin lymphoma survivors (n=289). For 42 patients, cardiac contours were outlined on each patient's simulation X-ray by 4 different raters, and the mean heart dose was estimated as the percentage of the cardiac contour within the radiation field multiplied by the prescribed mediastinal dose and divided by a correction factor obtained by comparison with individual CT-based dosimetry. Results: According to the simulation X-ray method, the medians of the mean heart doses obtained from the cardiac contours outlined by the 4 raters were 30 Gy, 30 Gy, 31 Gy, and 31 Gy, respectively, following prescribed mediastinal doses of 25-42 Gy. The absolute-agreement intraclass correlation coefficient was 0.93 (95% confidence interval 0.85-0.97), indicating excellent agreement. Mean heart dose was 30.4 Gy with the simulation X-ray method, versus 30.2 Gy with the representative CT-based dosimetry, and the between-method absolute-agreement intraclass correlation coefficient was 0.87 (95% confidence interval 0.80-0.95), indicating good agreement between the two methods. Conclusion: Estimating mean heart dose from radiation therapy simulation X-rays is reproducible and fast, takes individual anatomy into account, and yields results comparable to the labor-intensive representative CT-based method. This simpler method may produce a meaningful measure of mean heart dose for use in studies of late cardiac complications.

62 RADIOLOGY AND NUCLEAR MEDICINE↗

Lithium-ion battery physics and statistics-based state of health model

A pseudo-2d model using COMSOL Multiphysics® software is developed to simulate performance and performance degradation of Li-ion batteries consisting of layered and olivine cathodes with graphite anode when subjected to peak shaving grid service. Multiple degradation pathways are considered, including solid electrolyte interphase (SEI) formation and breakdown at the anode, cathode dissolution and its synergistic effect on SEI formation at the anode. The model is validated by simulating commercial cylindrical cell performance. A global model is developed to simulate performance across all chemistries, along with individual chemistry models using global model parameters as initial values. There is good agreement between these models for various optimization parameters such as SEI equilibrium potential, cathode dissolution exchange current density, solvent diffusivity in the SEI and SEI ionic conductivity. To circumvent time constraints related to the COMSOL model, a 0d global model is developed which fits data well and provides more clarity on differences in cathode dissolution exchange current density. Again, good agreement for various optimization parameters is obtained among the COMSOL global & individual chemistry models and the 0-d model. The lessons learned from the physics-based model is used to develop a top down statistics-based model using current, voltage and anode volumetric change per mole lithium intercalated, along with their interactions as degradation predictors. This model predicts out of sample degradation for multiple grid services and electric vehicle drive cycle with high accuracy and provides the pathway to develop an efficient battery management system combining machine learning and findings from physics-based computationally intensive algorithms.

Crawford, Aladsair J.↗

Plastic deformation of submicron-sized crystals studied by in-situ Kikuchi diffraction and dislocation imaging

The plastic deformation of submicron-size copper single crystals in the form of pillars has been characterized during in-situ compression in the transmission electron microscope up to strains of 28-33% using a state-of-the-art holder (PI-95 PicoIndenter). The dimensions of the crystals used were approx. 500 Multiplication-Sign 250 Multiplication-Sign 200 nm{sup 3} with the compression axis oriented 1.6 Degree-Sign from [110]. Local crystallographic orientations have been determined with high accuracy using a Kikuchi diffraction method and glide of dislocations over a pillar has also been observed directly by dark field imaging. The variation in the local orientation during deformation has been followed by in-situ convergent beam electron Kikuchi diffraction. The in-situ observations have been followed up by post-deformation measurements with the samples still mounted in the electron microscope. Crystal breakup following localized deformation was observed in two of three crystals examined, and for all crystals the direction of rotation during deformation is in agreement with slip taking place on a subset of the four slip systems, with the highest Schmid factors on the (111) and (- 1-11) slip planes. A diffraction-based Burgers vector analysis confirms that the active dislocations are from slip systems with the highest Schmid factors. These results from testing of micropillars are in good agreement with the deformation behaviour previously reported for both single- and poly-crystal samples with dimensions in the millimetre range. - Highlights: Black-Right-Pointing-Pointer We performed in-situ plastic deformation of submicron-sized copper single crystals. Black-Right-Pointing-Pointer We measured in-situ and ex-situ crystal rotation and imaged dislocation activities. Black-Right-Pointing-Pointer We measured crystallographic orientations and analyzed dislocation Burgers vectors. Black-Right-Pointing-Pointer Crystals' rotation in agreement with slip of dislocations with highest Schmid factor. Black-Right-Pointing-Pointer These results in good agreement with millimeter-scale samples' deformation behavior.

36 MATERIALS SCIENCE↗

Clustering instabilities in sedimenting fluid–solid systems: critical assessment of kinetic-theory-based predictions using direct numerical simulation data

In this paper the quantitative and qualitative ability of a kinetic-theory-based two-fluid model (KT-TFM) is assessed in a state of fully periodic sedimentation (fluidization), with a focus on statistically steady, unstable (clustered) states. The accuracy of KT-TFM predictions is evaluated via direct comparison to direct numerical simulation (DNS) data. The KT-TFM and DNS results span a rather wide parameter space: mean-flow Reynolds numbers on the order of 1 and 10, mean solid volume fractions from 0.1 to 0.4, solid-to-fluid density ratios from 10 to 1000 and elastic and moderately inelastic (restitution coefficient of 0.9) conditions. Data from both KT-TFM and DNS display a rich variety of statistically steady yet unstable structures (clusters). Instantaneous snapshots of KT-TFM and DNS demonstrate remarkable qualitative agreement. This qualitative agreement is quantified by calculating the critical density ratio at which the structure transitions from a chaotic, dynamic state to a regular, plug-flow state, with good overall comparisons. Further quantitative assessments of mean and fluctuating velocities show good agreement at high density ratios but weaker agreement at intermediate to low density ratios depending on the mean-flow Reynolds numbers and solid fractions. Deviations of the KT-TFM results from the DNS data were traced to a breakdown in one of the underlying assumptions of the kinetic theory derivation: high thermal Stokes number. Surprisingly, however, even though the low Knudsen number assumption, also associated with the kinetic theory derivation, is violated throughout most of the parameter space, it does not seem to affect the good quantitative accuracy of KT-TFM simulations.

42 ENGINEERING↗

Quantum Chemical Calculations of the Cl- + CH3I → CH3Cl + I- Potential Energy Surface

Electronic structure theory calculations, using MP2 theory and the DFT functionals OPBE, OLYP, HCTH407, BhandH, and B97-1, were performed to characterize the structures, vibrational frequencies, and energies for stationary points on the Cl- + CH3I → ClCH3 + I- potential energy surface. The aug-cc-pVDZ and aug-cc-pVTZ basis sets, with an effective core potential (ECP) for iodine, were employed. Single-point CCSD(T) calculations were performed to obtain the complete basis set (CBS) limit for the reaction energies. DFT was found to give significantly longer halide ion/carbon atom bond lengths for the ion-dipole complexes and central barrier transition state, than MP2. BhandH, with either the aug-cc-pVDZ and aug-cc-pVTZ basis sets, gives good agreement with the experimental structures for both CH3I and CH3Cl. The frequencies of CH3I and CH3Cl, obtained with the different level of theory and basis sets, are in excellent agreement with experiment. The major difference between the MP2 and DFT frequencies is for the imaginary frequency of the central barrier. Using the aug-cc-pVTZ basis the MP2 value for this frequency ranges from 1.26 - 1.59 times larger than those for the DFT functional. Thus, the MP2 and DFT theories have different PES shapes in the vicinity of the [Cl--CH3--I]- central barrier. The CCSD(T)/CBS energies are in good agreement with experiments for the complexation energies and reaction exothermicity, with a small 1 kcal/mol difference for the latter. The CCSD(T)/CBS central barrier height is lower than values deduced by using statistical theoretical models to fit the Cl- + CH3I → ClCH3 + I- experimental rate constant, which is consistent with the expected non-statistical dynamics for the reaction. The BhandH energies are in overall best agreement with the CCSD(T) values, with a largest difference of only 0.7 kcal/mol.

37 INORGANIC, ORGANIC, PHYSICAL, AND ANALYTICAL CH↗