Engineering Papers⌕ Search

SEARCH · Engineering Papers

Results for “aberrations”

Search indexed NASA NTRS and DOE OSTI research on propulsion, heat transfer, battery materials and energy systems. Follow report and document links to the original sources.

Quote a phrase for an exact phrase match. Source license links do not imply unrestricted reuse.

At least 433 records · Page 24

Science Yield Estimates and Sensitivities With the AstroPIC Integrated Photonic Coronagraph for the Habitable Worlds Observatory

The Habitable Worlds Observatory (HWO) flagship has a goal to survey ~100 of the nearest stellar systems and their habitable zones in order to detector and spectroscopically characterize ~25 potentially “Earth-like planets” (or “Exoearths”). The HWO telescope will feature a >6-m diameter aperture and a coronagraph that will suppress starlight by ten orders of magnitude to enable the detection and characterization of Earth analogues in the habitable zone. Three Exploratory Analytic Cases (EACs) are currently considering different aperture configurations for HWO including on-axis and off-axis apertures and both different hexagonal and keystone segmentation configurations. Photonic Integrated Circuits (PICs) offer a path to miniaturize traditional, bulk optics coronagraph functionality reducing risk margins and increasing mission science exoearth yields for the HWO mission. We have developed a simulation pipeline that enables evaluation of the AstroPIC photonic integrated coronagraph through to estimates mission yields. We present sensitivities to aberrations for different types of segmentation and low-order aberrations for HWO EACs demonstrating that AstroPIC is suitable for both on-axis and off-axis configurations. We perform a parametric sweep of the exoearth science yield sensitivities in terms of key coronagraph parameters including coronagraphic end-to-end throughput, inner working angle, robustness to aberrations, and bandwidth. We consider both a hybrid and a pure photonic architecture; a pure integrated photonic architecture provides the greatest potential in science yield improvements, although a hybrid PIC limited in its numbers of modes can provide complementary science to a traditional, bulk-optic coronagraph and increasing the estimated science yield when operated jointly.

Photonics↗

Performance predictions of a focused ion beam from a laser cooled and compressed atomic beam

Focused ion beams are indispensable tools in the semiconductor industry because of their ability to image and modify structures at the nanometer length scale. Here, we report on performance predictions of a new type of focused ion beam based on photo-ionization of a laser cooled and compressed atomic beam. Particle tracing simulations are performed to investigate the effects of disorder-induced heating after ionization in a large electric field. They lead to a constraint on this electric field strength which is used as input for an analytical model which predicts the minimum attainable spot size as a function of, amongst others, the flux density of the atomic beam, the temperature of this beam, and the total current. At low currents (I < 10 pA), the spot size will be limited by a combination of spherical aberration and brightness, while at higher currents, this is a combination of chromatic aberration and brightness. It is expected that a nanometer size spot is possible at a current of 1 pA. The analytical model was verified with particle tracing simulations of a complete focused ion beam setup. A genetic algorithm was used to find the optimum acceleration electric field as a function of the current. At low currents, the result agrees well with the analytical model, while at higher currents, the spot sizes found are even lower due to effects that are not taken into account in the analytical model.

43 PARTICLE ACCELERATORS↗

Examination of clonal evolution in chronic lymphocytic leukemia

Chronic lymphocytic leukemia (CLL) is one of the most frequent lymphoproliferative diseases. CLL is characterized by unusual heterogeneity, which probably reflects its biological and genetic lack of homogeneity. Clonal chromosome aberrations belong to the most important prognostic and predictive factors in CLL. This research was aimed at observing clonal evolution in CLL at the chromosomal level, and assessing its clinical significance in relation to selected prognostic factors. The study involved 72 untreated patients with CLL. The preliminary investigations using cytogenetic banding analysis (CBA) and FISH were performed at the time of diagnosis, and again after about 24 months to observe clonal changes (clonal evolution). In addition, other parameters were evaluated, i.e., the expression of ZAP-70 kinase, CD38 antigen, and the mutation statuses of IGVH and NOTCH1 genes. Classic prognostic factors, i.e., categorized ZAP70 and CD38 expressions as well as mutations in IGVH and NOTCH1 genes did not influence the course of clonal evolution in the examined group of patients. Clonal evolution was detected in 45.8% of patients by means of CBA, and in 19.4% patients with FISH. Analysis of chromosomal aberrations in the examined group of patients showed that the incidence of 17p deletions and translocations in karyotypes has a negative impact on overall survival. CE was found to be a risk factor for the occurrence of disease progression (OR = 2.22). Our observations indicate that combined CBA and FISH are the most optimal techniques for monitoring clonal evolution in the course of CLL.

62 RADIOLOGY AND NUCLEAR MEDICINE↗

Cytogenetic Low-Dose Hyperradiosensitivity Is Observed in Human Peripheral Blood Lymphocytes

Purpose: The shape of the ionizing radiation response curve at very low doses has been the subject of considerable debate. Linear-no-threshold (LNT) models are widely used to estimate risks associated with low-dose exposures. However, the low-dose hyperradiosensitivity (HRS) phenomenon, in which cells are especially sensitive at low doses but then show increased radioresistance at higher doses, provides evidence of nonlinearity in the low-dose region. HRS is more prominent in the G2 phase of the cell cycle than in the G0/G1 or S phases. Here we provide the first cytogenetic mechanistic evidence of low-dose HRS in human peripheral blood lymphocytes using structural chromosomal aberrations. Methods and Materials: Human peripheral blood lymphocytes from 2 normal healthy female donors were acutely exposed to cobalt 60 γ rays in either G0 or G2 using closely spaced doses ranging from 0 to 1.5 Gy. Structural chromosomal aberrations were enumerated, and the slopes of the regression lines at low doses (0-0.4 Gy) were compared with doses of 0.5 Gy and above. Results: HRS was clearly evident in both donors for cells irradiated in G2. No HRS was observed in cells irradiated in G0. The radiation effect per unit dose was 2.5- to 3.5-fold higher for doses ≤0.4 Gy than for doses >0.5 Gy. Conclusions: These data provide the first cytogenetic evidence for the existence of HRS in human cells irradiated in G2 and suggest that LNT models may not always be optimal for making radiation risk assessments at low doses.

62 RADIOLOGY AND NUCLEAR MEDICINE↗

Detection and Automated Scoring of Dicentric Chromosomes in Nonstimulated Lymphocyte Prematurely Condensed Chromosomes After Telomere and Centromere Staining

Purpose: To combine telomere and centromere (TC) staining of premature chromosome condensation (PCC) fusions to identify dicentrics, centric rings, and acentric chromosomes, making possible the realization of a dose–response curve and automation of the process. Methods and Materials: Blood samples from healthy donors were exposed to {sup 60}Co irradiation at varying doses up to 8 Gy, followed by a repair period of 8 hours. Premature chromosome condensation fusions were carried out, and TC staining using peptide nucleic acid probes was performed. Chromosomal aberration (CA) scoring was carried out manually and automatically using PCC-TCScore software, developed in our laboratory. Results: We successfully optimized the hybridization conditions and image capture parameters, to increase the sensitivity and effectiveness of CA scoring. Dicentrics, centric rings, and acentric chromosomes were rapidly and accurately detected, leading to a linear-quadratic dose–response curve by manual scoring at up to 8 Gy. Using PCC-TCScore software for automatic scoring, we were able to detect 95% of dicentrics and centric rings. Conclusion: The introduction of TC staining to the PCC fusion technique has made possible the rapid scoring of unstable CAs, including dicentrics, with a level of accuracy and ease not previously possible. This new approach can be used for biological dosimetry in radiation emergency medicine, where the rapid and accurate detection of dicentrics is a high priority using automated scoring. Because there is no culture time, this new approach can also be used for the follow-up of patients treated by genotoxic therapy, creating the possibility to perform the estimation of induced chromosomal aberrations immediately after the blood draw.

62 RADIOLOGY AND NUCLEAR MEDICINE↗

Breaking the Crowther limit: Combining depth-sectioning and tilt tomography for high-resolution, wide-field 3D reconstructions

To date, high-resolution (<1 nm) imaging of extended objects in three-dimensions (3D) has not been possible. A restriction known as the Crowther criterion forces a tradeoff between object size and resolution for 3D reconstructions by tomography. Further, the sub-Angstrom resolution of aberration-corrected electron microscopes is accompanied by a greatly diminished depth of field, causing regions of larger specimens (>6 nm) to appear blurred or missing. We demonstrate a three-dimensional imaging method that overcomes both these limits by combining through-focal depth sectioning and traditional tilt-series tomography to reconstruct extended objects, with high-resolution, in all three dimensions. The large convergence angle in aberration corrected instruments now becomes a benefit and not a hindrance to higher quality reconstructions. A through-focal reconstruction over a 390 nm 3D carbon support containing over 100 dealloyed and nanoporous PtCu catalyst particles revealed with sub-nanometer detail the extensive and connected interior pore structure that is created by the dealloying instability.

3D imaging↗

A short story of imaging and spectroscopy of two-dimensional materials by scanning transmission electron microscopy

Here we present a short historical account of when single adatom impurities where first identified in two-dimensional materials by scanning transmission electron microscopy (STEM). We also present a study of the graphene low-loss (below 50 eV) response as a function of number of layers using electron energy-loss spectroscopy (EELS). The study shows that as few as three layers of graphene behave as bulk graphite for losses above 10 eV We also show examples of how point and extended defects can easily be resolved and structural dynamics can be readily capture by using aberration-corrected STEM imaging. Lastly, we show that the new generation of monochromators has opened up possibilities to explore new physics with an electron microscope. All these capabilities were enabled by the development of spherical aberration correctors and monochromators, where Ondrej Krivanek has played a key role.

2D materials↗

A novel electron mirror pulse compressor

An electron mirror-based pulse compressor design has been developed for improving the temporal resolution of dynamic/ultrafast transmission electron microscopes and ultrafast electron diffraction cameras. The improvement will enable electron microscopes and diffraction cameras to better resolve the dynamics of reactions in the areas of solid state physics, chemistry, and biology. The design utilizes a combination of mirror optics and a magnetic beam separator, which exploits the symmetry inherent in reversing the electron trajectory in the mirror in order to compress the pulse. This system can also simultaneously correct the spherical and chromatic aberration of the objective lens for improved spatial resolution. For pulsed experiments with a practical bunch charge, the correction of the chromatic aberration coefficient counters the spread in the electron energies induced by the space charge of the pulse to make possible the probing of the sample with high spatial resolution. The pulse compressor can accommodate pulses with a range of electron densities and energy spreads. Additionally, it is designed to fit into both ultrafast electron diffraction cameras and dynamic/ultrafast transmission electron microscopes. Consequently, this instrument is suitable for enhancing the study of the structure, composition, and bonding states of new materials at ultrafast time scales.

47 OTHER INSTRUMENTATION↗

Atomic to Nanoscale Investigation of Functionalities of an Al2O3 Coating Layer on a Cathode for Enhanced Battery Performance

Surface coating has been identified as an effective approach for enhancing the capacity retention of layered structure cathode. However, the underlying operating mechanism of such a thin coating layer, in terms of surface chemical functionality and capacity retention, remains unclear. In this work, we use aberration-corrected scanning transmission electron microscopy and high-efficiency spectroscopy to probe the delicate functioning mechanism of an Al2O3 coating layer on a Li1.2Ni0.2Mn0.6O2 cathode. We discovered that in terms of surface chemical function, the Al2O3 coating suppresses the side reaction between the cathode and the electrolyte during battery cycling. At the same time, the Al2O3 coating layer also eliminates the chemical reduction of Mn from the cathode particle surface, therefore preventing the dissolution of the reduced Mn into the electrolyte. In terms of structural stability, we found that the Al2O3 coating layer can mitigate the layer to spinel phase transformation, which otherwise will be initiated from the particle surface and propagate toward the interior of the particle with the progression of battery cycling. The atomic to nanoscale effects of the coating layer observed here provide insight into the optimized design of a coating layer on a cathode to enhance the battery properties.

Yan, Pengfei↗

Optical designs of reflection and refraction collection optics for a JT-60SA core Thomson scattering system

Collection optics for core measurements in a JT-60SA Thomson scattering system were designed. The collection optics will be installed in a limited space and have a wide field of view and wide wavelength range. Two types of the optics are therefore suggested: refraction and reflection types. The reflection system, with a large primary mirror, avoids large chromatic aberrations. Because the size limit of the primary mirror and vignetting due to the secondary mirror affect the total collection throughput, conditions that provide the high throughput are found through an optimization. A refraction system with four lenses forming an Ernostar system is also employed. The use of high-refractive-index glass materials enhances the freedom of the lens curvatures, resulting in suppression of the spherical and coma aberration. Moreover, sufficient throughput can be achieved, even with smaller lenses than that of a previous design given in [H. Tojo, T. Hatae, T. Sakuma, T. Hamano, K. Itami, Y. Aida, S. Suitoh, and D. Fujie, Rev. Sci. Instrum. 81, 10D539 (2010)]. The optical resolutions of the reflection and refraction systems are both sufficient for understanding the spatial structures in plasma. In particular, the spot sizes at the image of the optics are evaluated as ∼0.3 mm and ∼0.4 mm, respectively. The throughput for the two systems, including the pupil size and transmissivity, are also compared. The results show that good measurement accuracy (<10%) even at high electron temperatures (<30 keV) can be expected in the refraction system.

46 INSTRUMENTATION RELATED TO NUCLEAR SCIENCE AND ↗

Direct observation of the structural and electronic changes of Li{sub 2}MnO{sub 3} during electron irradiation

This study focuses on the effects of electron beam induced irradiation to the layered oxide Li{sub 2}MnO{sub 3}. Aberration-corrected scanning transmission electron microscopy and electron energy loss spectroscopy are used to characterize structural and electronic transitions in the material during irradiation, with a focus on changes in Mn valence and O content. This truly in situ irradiation allows for specific particle tracking, dose quantification, and real-time observation, while demonstrating many parallels to the oxide's structure evolution observed during electrochemical cycling. Furthermore, it is demonstrated that typical imaging conditions are not severe enough to induce damage to the pristine oxide.

75 CONDENSED MATTER PHYSICS, SUPERCONDUCTIVITY AND↗

Hyperspectral radiance mapping and chromatic correction for temperature measurement in laser-heated diamond anvil cells

In laser-heated diamond anvil cell (DAC) experiments, the effective heated region typically decreases in size with increasing pressure, leading to steeper thermal gradients. Under these conditions, chromatic aberration in the optical path from sample to detector can significantly create bias in spectro-radiometric temperature measurement. We present a radiance-mapping approach using a hyperspectral camera that records 25 spectral channels spanning 605–875 nm at each pixel in a single exposure, providing spatially and spectrally resolved radiance in each frame. This enables chromatic effects to be recorded and corrected in data processing. We developed a procedure for hyperspectral mapping, involving per-camera calibration, crosstalk removal, measured spectral throughput functions, and optional sub-pixel co-registration to minimize chromatic distortion. The calibrated radiance maps are then used to derive temperature maps of the laser-heated hotspots. For smaller heating spots, the radiance mapping approach reveals chromatic shifts that conventional spectro-radiometric methods cannot quantify. Ambient-pressure heating experiments confirm accurate temperature retrieval. At high pressure, application of the hyperspectral system to a platinum-heating experiment at 12 GPa demonstrates stable temperature reconstruction under steep thermal gradients. Beyond mitigating chromatic aberrations, the ability to diagnose optical artifacts separately from emissivity variations during controlled test experiments or in situ suggests a path toward more rigorous spectral emissivity analysis and improved modeling of thermal transport in laser-heated DAC experiments.

47 OTHER INSTRUMENTATION↗

Ultra-high resolution electron microscopy

The last two decades have seen dramatic advances in the resolution of the electron microscope brought about by the successful correction of lens aberrations that previously limited resolution for most of its history. Here we briefly review these advances, the achievement of sub-Ångstrom resolution and the ability to identify individual atoms, their bonding configurations and even their dynamics and diffusion pathways. We then present a review of the basic physics of electron scattering, lens aberrations and their correction, and an approximate imaging theory for thin crystals which provides physical insight into the various different imaging modes. Then we proceed to describe a more exact imaging theory starting from Yoshioka’s formulation and covering full image simulation methods using Bloch waves, the multislice formulation and the frozen phonon/quantum excitation of phonons models. Delocalization of inelastic scattering has become an important limiting factor at atomic resolution. We therefore discuss this issue extensively, showing how the full-width-half-maximum is the appropriate measure for predicting image contrast, but the diameter containing 50% of the excitation is an important measure of the range of the interaction. These two measures can differ by a factor of 5, are not a simple function of binding energy, and full image simulations are required to match to experiment. The Z-dependence of annular dark field images is also discussed extensively, both for single atoms and for crystals, and we show that temporal incoherence must be included accurately if atomic species are to be identified through matching experimental intensities to simulations. Finally we mention a few promising directions for future investigation.

71 CLASSICAL AND QUANTUM MECHANICS, GENERAL PHYSIC↗

Ion-Optical System of an Ion Source with Energy Focusing in the Formed Beam

Ways to reduce ion beam intensity losses in a mass spectrometric ion source, which are caused by chromatic aberration of its immersion ion-optical system, are considered. These losses are rather significant in forming a beam from ions with a large energy spread. The reduction of aberration losses is especially important when ion sources are used jointly with mass analyzers with energy focusing. It is shown that these losses can be reduced significantly by using a new type of ion-optical system of the ion source, which includes achromatic elements. A special method for calculating such elements is given. Computer simulations have shown high efficiency of such elements in the ion-optical path of ion sources of mass spectrometers.

71 CLASSICAL AND QUANTUM MECHANICS, GENERAL PHYSIC↗

Radiation-induced genomic instability: radiation quality and dose response

Genomic instability is a term used to describe a phenomenon that results in the accumulation of multiple changes required to convert a stable genome of a normal cell to an unstable genome characteristic of a tumor. There has been considerable recent debate concerning the importance of genomic instability in human cancer and its temporal occurrence in the carcinogenic process. Radiation is capable of inducing genomic instability in mammalian cells and instability is thought to be the driving force responsible for radiation carcinogenesis. Genomic instability is characterized by a large collection of diverse endpoints that include large-scale chromosomal rearrangements and aberrations, amplification of genetic material, aneuploidy, micronucleus formation, microsatellite instability, and gene mutation. The capacity of radiation to induce genomic instability depends to a large extent on radiation quality or linear energy transfer (LET) and dose. There appears to be a low dose threshold effect with low LET, beyond which no additional genomic instability is induced. Low doses of both high and low LET radiation are capable of inducing this phenomenon. This report reviews data concerning dose rate effects of high and low LET radiation and their capacity to induce genomic instability assayed by chromosomal aberrations, delayed lethal mutations, micronuclei and apoptosis.

Review↗

Estimate of true incomplete exchanges using fluorescence in situ hybridization with telomere probes

PURPOSE: To study the frequency of true incomplete exchanges in radiation-induced chromosome aberrations. MATERIALS AND METHODS: Human lymphocytes were exposed to 2 Gy and 5 Gy of gamma-rays. Chromosome aberrations were studied using the fluorescence in situ hybridization (FISH) technique with whole chromosome-specific probes, together with human telomere probes. Chromosomes 2 and 4 were chosen in the present study. RESULTS: The percentage of incomplete exchanges was 27% when telomere signals were not considered. After excluding false incomplete exchanges identified by the telomere signals, the percentage of incomplete exchanges decreased to 11%. Since telomere signals appear on about 82% of the telomeres, the percentage of true incomplete exchanges should be even lower and was estimated to be 3%. This percentage was similar for chromosomes 2 and 4 and for doses of both 2 Gy and 5 Gy. CONCLUSIONS: The percentage of true incomplete exchanges is significantly lower in gamma-irradiated human lymphocytes than the frequencies reported in the literature.

NASA Discipline Radiation Health↗

Biodosimetry results from space flight Mir-18

Astronauts are classified as radiation workers due to the presence of ionizing radiation in space. For the assessment of health risks, physical dosimetry has been indispensable. However, the change of the location of dosimeters on the crew members, the variation in dose rate with location inside the spacecraft and the unknown biological effects of microgravity can introduce significant uncertainties in estimating exposure. To circumvent such uncertainty, a study on the cytogenetic effects of space radiation in human lymphocytes was proposed and conducted for Mir-18, a 115-day mission. This study used fluorescence in situ hybridization (FISH) with whole-chromosome painting probes to score chromosomal exchanges and the Giemsa staining method to determine the frequency of dicentrics. The growth kinetics of cells and sister chromatid exchanges (SCEs) were examined to ensure that chromosomal aberrations were scored in the first mitosis and were induced primarily by space radiation. Our results showed that the frequency of chromosomal aberrations increased significantly in postflight samples compared to samples drawn prior to flight, and that the frequency of SCEs was similar for both pre- and postflight samples. Based on a dose-response curve for preflight samples exposed to gamma rays, the absorbed dose received by crew members during the mission was estimated to be about 14.75 cSv. Because the absorbed dose measured by physical dosimeters is 5.2 cGy for the entire mission, the RBE is about 2.8.

NASA Discipline Radiation Health↗

Centric rings, acentric rings and excess acentric fragments based on a random-walk interphase chromosome model

Excess acentric fragments, consisting of acentric rings and acentric linear fragments, are among the most frequent kinds of chromosome-type aberrations produced by radiation. The frequency of acentric rings cannot be obtained directly by experiment but is estimated here from the ratio of acentric to centric rings, evaluated using a random-walk model for the organization of chromatin during interphase and an assumption that the probability of an exchange formation is proportional to the rate of collision between two DSB. This ratio is calculated to be 2.5 in low-LET irradiated human fibroblasts, significantly greater than the ratio if proximity effects are not considered. The calculated frequency of acentric rings is insufficient to account for all the observed excess acentric fragments. Assuming that the rest of the excess acentric fragments are due to incomplete exchanges, all possible recombinations between two DSB that result in acentric rings and acentric linear fragments have been identified. From the chromosome aberration data, the incompleteness parameter has been estimated. Intra-arm chromosome exchanges, either complete or incomplete, were estimated to account for more than 50% of the excess acentric fragments in human fibroblasts.

NASA Center JSC↗