Engineering Papers⌕ Search

SEARCH · Engineering Papers

Results for “Water System”

Search indexed NASA NTRS and DOE OSTI research on propulsion, heat transfer, battery materials and energy systems. Follow report and document links to the original sources.

Quote a phrase for an exact phrase match. Source license links do not imply unrestricted reuse.

At least 433 records · Page 24

Cost analysis of water recovery systems

A methodology was developed to predict the relevant contributions of the more intangible cost elements encountered in the development of flight-qualified hardware based on an extrapolation of past hardware development experience. Major items of costs within water recovery systems were identified and related to physical and/or performance criteria. Cost and performance data from Gemini, Skylab, and other aerospace and biotechnology programs were analyzed to identify major cost elements required to establish cost estimating relationships for advanced water recovery systems. The results of the study are expected to assist NASA in long-range planning and allocation of resources in a cost effective manner in support of earth orbital programs. This report deals with the cost analysis of the five leading water reclamation systems, namely: (1) RITE waste management-water system, (2) reverse osmosis system, (3) multifiltration system, (4) vapor compression system, and (5) closed air evaporation system with electrolytic pretreatment.

Yakut, M. M.↗

Gas and water recycling system for IOC vivarium experiments

Water and gas recycling units designed as one of the common experiment support system for the life science experiment facilities used in the Japanese Experiment Module are discussed. These units will save transportation and operation costs for the life science experiments in the space station. These units are also designed to have interfaces so simple that the connection to another life science experiment facilities such as the Research Animal Holding Facility developed by the Rockheed Missiles and Space Company can be easily done with small modification.

Nitta, K.↗

Experimental investigation of the small-scale prototype of the dew point water recovery system

The article presents experimental investigation of the Dew Point Water Recovery (DPWR) system designed for clean water recovery using the dew point cooling phenomenon. The technology is a novel distillation process which allows for highly efficient water recovery. It is a first distillation technology which allows for water distillation through direct contact with atmospheric air. The authors designed, built, and tested an original prototype of a laboratory-scale DPWR system to verify its basic operating principles and perform performance analysis. It was shown that on average 10 × 10 −6 m 3 of clean water could be recovered from each cubic meter of the supply air with an average GOR of 1.9. Although the operation of the DPWR system requires electricity to drive fans, pumps and other associated equipment, the actual driving force of the system is thermal energy. The average thermal energy demand of the DPWR system was 370 kWh/m 3 , and more than half of this energy was based on the thermodynamic potential of the supply air. Based on experimental data, the mathematical model of the DPWR system was verified and it was found that the average relative discrepancy in predicting air temperature did not exceed 8%, and in predicting air humidity: 5%. In conclusion, the conducted experiments confirmed that the proposed DPWR system is feasible and has the potential to fill the technological gap in terms of a low-energy and easily accessible water recovery method.

42 ENGINEERING↗

Water hyacinths for removal of cadmium and nickel from polluted waters

Removal of cadmium and nickel from static water systems utilizing water hyacinths (Eichhornia crassipes (Mart.) Solms) was investigated. This aquatic plant demonstrated the ability to rapidly remove heavy metals from aqueous systems by root absorption and concentration. Water hyacinths demonstrated the ability to absorb and concentrate up to 0.67 mg of cadmium and 0.50 mg of nickel per gram of dry plant material when exposed for a 24-hour period to waters polluted with from 0.578 to 2.00 ppm of these toxic metals. It is found that one hectare of water hyacinths has the potential of removing 300 g of cadmium or nickel from 240,000 liters of water polluted with these metals during a 24-hour period.

Wolverton, B. C.↗

Remote water-monitoring system

General-purpose, water-quality sampling process detects microorganisms and integrates sampling, sample preservation, and sample analysis. System overcomes difficulties in correlation of surface measurements with remote measurements and minimizes human error in handling of samples and instrumentation.

Grana, D. C.↗

Building America Case Study: Control Retrofits for Multifamily Domestic Hot Water Recirculation Systems, Brooklyn, New York

Domestic hot water (DHW) heating is the second largest energy end use in U.S. buildings, exceeded only by space conditioning. Recirculation systems consisting of a pump and piping loop(s) are commonly used in multifamily buildings to reduce wait time for hot water at faucets; however, constant pumping increases energy consumption by exposing supply and return line piping to continuous heat loss, even during periods when there is no demand for hot water. In this study, ARIES installed and tested two types of recirculation controls in a pair of buildings in order to evaluate their energy savings potential. Demand control, temperature modulation controls, and the simultaneous operation of both were compared to the baseline case of constant recirculation. Additionally, interactive effects between DHW control fuel reductions and space conditioning (heating and cooling) were estimated in order to make more realistic predictions of the payback and financial viability of retrofitting DHW systems with these controls. Results showed that DHW fuel consumption reduced by 7% after implementing the demand control technique, 2% after implementing temperature modulation, and 15% after implementing demand control and temperature modulation techniques simultaneously; recirculation pump runtime was reduced to 14 minutes or less per day. With space heating and cooling interactions included, the estimated annual cost savings were 8%, 1%, and 14% for the respective control techniques. Possible complications in the installation, commissioning and operation of the controls were identified and solutions offered.

ARIES↗

Building America Case Study: Control Retrofits for Multifamily Domestic Hot Water Recirculation Systems, Brooklyn, New York

Domestic hot water (DHW) heating is the second largest energy end use in U.S. buildings, exceeded only by space conditioning. Recirculation systems consisting of a pump and piping loop(s) are commonly used in multifamily buildings to reduce wait time for hot water at faucets; however, constant pumping increases energy consumption by exposing supply and return line piping to continuous heat loss, even during periods when there is no demand for hot water. In this study, ARIES installed and tested two types of recirculation controls in a pair of buildings in order to evaluate their energy savings potential. Demand control, temperature modulation controls, and the simultaneous operation of both were compared to the baseline case of constant recirculation. Additionally, interactive effects between DHW control fuel reductions and space conditioning (heating and cooling) were estimated in order to make more realistic predictions of the payback and financial viability of retrofitting DHW systems with these controls. Results showed that DHW fuel consumption reduced by 7 percent after implementing the demand control technique, 2 percent after implementing temperature modulation, and 15 percent after implementing demand control and temperature modulation techniques simultaneously; recirculation pump runtime was reduced to 14 minutes or less per day. With space heating and cooling interactions included, the estimated annual cost savings were 8 percent, 1 percent, and 14 percent for the respective control techniques. Possible complications in the installation, commissioning and operation of the controls were identified and solutions offered.

32 ENERGY CONSERVATION, CONSUMPTION, AND UTILIZATI↗

Water Cleaning System for the Exhaust Pipe of HLW Glass Melter (LFCM) - 17180

Vitrification technology has been generally applied to stabilize High-Level Radioactive Waste (HLW) generated from spent fuel reprocessing. In Japan, Joule Heated Liquid Fed Ceramic Melter (LFCM) system is selected for HLW vitrification and the recent active test has been successfully demonstrated its stable operation. The higher reliability of off-gas treatment system (OGTS) which consists of wet scrubber, absorbers and filters connected to the LFCM is also important to ensure long term system operation. The OGTS removes radioactive gases, mists and dust generated by LFCM and maintains radioactive containments by keeping negative pressure inside. In the past active and inactive tests, it was observed that differential pressure in the exhaust pipe attached to LFCM gradually increased during continuous operation and some deposits were observed inside the off-gas pipe. So the cleaning operation needs to be improved and more frequent in order to avoid the exhaust pipe clogging. Therefore we investigated several cleaning systems and operational methods for the exhaust pipe of LFCM. As a result, we have successfully developed the modified water cleaning system. In this presentation we will introduce our water cleaning system. In addition, we will present the result of inactive mock-up tests for the visualization of this water cleaning system. (authors)

12 MANAGEMENT OF RADIOACTIVE AND NON-RADIOACTIVE W↗

Silver Ion Biocide Delivery System for Water Disinfection

U.S. space exploration missions have long considered returning to the Moon and exploration of Mars that challenge life support systems. For these long duration missions, there is interest in replacing the iodine water treatment system with ionic silver, a proven biocide. For long duration exploration missions, it is imperative that an effective biocide be used that prevents microbial growth, biofilm formation, and microbially induced corrosion in the water storage and distribution systems while minimizing logistical supply requirements associated with the biocide delivery system. Two biocide delivery systems have been developed that electrochemically produce silver ions for disinfecting water throughout the water storage and distribution system. One system uses a newly developed hybrid micro-filtration and ion-exchange membrane to produce an abundance of silver ions at the 1000 ppb level upstream in the water distribution system to prevent biofilm growth. This is followed by a downstream collection module that electrochemically removes these silver ions before the water is discharged. Another approach uses a membraneless reactor to produce a 1000 ppb silver ion concentration level that also has a mechanically driven electrode cleaning mechanism that removes oxide films ensuring long life operation. By maintaining a sufficiently high level of silver ions throughout the water storage and distribution system, biofilm formation is suppressed. This approach overcomes present concerns where spurious silver deposition occurs on the container and flow line surfaces thus lowering the silver ion concentration to unsatisfactory disinfection levels.

Slote, Benjamin M.↗

Methods identifying cost reduction potential for water electrolysis systems

The electrochemical reduction of water to form hydrogen is an emerging alternative for energy storage, where hydrogen can be used as a transportation fuel, combusted to generate electricity, utilized in a fuel cell, or used as a feedstock for chemical synthesis. Techno-economic analysis (TEA) is a valuable tool for understanding how to inform research directions that could make hydrogen from electrolysis cost competitive with that produced by conventional means like steam methane reforming. The current state of knowledge on TEA of electrolysis systems suggests cost reductions are likely to result from advances in system design and materials, scale-up of manufacturing processes, and learning by doing effects as electrolysis deployment increases. Future directions and opportunities for TEA of electrolysis systems include dispatchable operation in wholesale power markets, optimization of capital cost and system durability, and analysis of pathways for hydrogen to support economy-wide decarbonization.

08 HYDROGEN↗

Urine pretreatment for waste water processing systems

Recovery of high quality water from urine is an essential part of life support on a Space Station to avoid costly launch and resupply penalties. Water can be effectively recovered from urine by distillation following pretreatment by a chemical agent to inhibit microorganism contamination and fix volatile ammonia constituents. This paper presents the results of laboratory investigations of several pretreatment chemicals which were tested at several concentration levels in combination with sulfuric acid in urine. The optimum pretreatment formulation was then evaluated with urine in the Hamilton Standard Thermoelectric Integrated Membrane Evaporation Subsystem (TIMES). Over 2600 hours of test time was accumulated. Results of these laboratory and system tests are presented in this paper.

Winkler, H. E.↗

Model-Based Extracted Water Desalination System for Carbon Sequestration

Over the last 1.5 years, GE Global Research and Pennsylvania State University defined a model-based, scalable, and multi-stage extracted water desalination system that yields clean water, concentrated brine, and, optionally, salt. The team explored saline brines that ranged across the expected range for extracted water for carbon sequestration reservoirs (40,000 up to 220,000 ppm total dissolved solids, TDS). In addition, the validated the system performance at pilot scale with field-sourced water using GE’s pre-pilot and lab facilities. This project encompassed four principal tasks, in addition to Project Management and Planning: 1) identify a deep saline formation carbon sequestration site and a partner that are suitable for supplying extracted water; 2) conduct a techno-economic assessment and down-selection of pre-treatment and desalination technologies to identify a cost-effective system for extracted water recovery; 3) validate the downselected processes at the lab/pre-pilot scale; and 4) define the scope of the pilot desalination project. Highlights from each task are described below: Deep saline formation characterization The deep saline formations associated with the five DOE NETL 1260 Phase 1 projects were characterized with respect to their mineralogy and formation water composition. Sources of high TDS feed water other than extracted water were explored for high TDS desalination applications, including unconventional oil and gas and seawater reverse osmosis concentrate. Technoeconomic analysis of desalination technologies Techno-economic evaluations of alternate brine concentration technologies, including humidification-dehumidification (HDH), membrane distillation (MD), forward osmosis (FO), turboexpander-freeze, solvent extraction and high pressure reverse osmosis (HPRO), were conducted. These technologies were evaluated against conventional falling film-mechanical vapor recompression (FF-MVR) as a baseline desalination process. Furthermore, a quality function deployment (QFD) method was used to compare alternate high TDS desalination technologies to FF-MVR. High pressure reverse osmosis was found to a be a promising alternative desalination technology. A deep-dive technoeconomic analysis of HPRO was performed, including Capex and Opex estimates, for seawater RO (SWRO). Additionally, two additional cases were explored: 1) a comparison of a SWRO plus HPRO system to the option of doubling the size of a standard seawater RO system to achieve the same total pure water recovery rate; and 2) a flue gas desulfurization wastewater treatment zero-liquid discharge (ZLD) application, where preconcentration with RO (SWRO or SWRO + HPRO) before evaporation and crystallization was compared to FF-MVR and crystallization technologies without RO preconcentration. Pre-pilot process validation Pre-pilot-scale tests were conducted using field production water to validate key process steps for extracted water pretreatment. Approximately 5,000 gallons of field produced water was processed through, microfiltration, ultrafiltration, and steam regenerable sorbent operations. Smaller quantities were processed through microclarification. In addition, analytical methods (purge-and-trap gas chromatography and Hach TOC analytical methods) were validated. Lab-scale HPRO elements were constructed and tested at high pressures, to identify and mitigate technical risks of the technology. Lastly, improvements in RO membrane materials were identified as the necessary next step to achieve further improvement in element performance at high pressure. Scope of Field Pilot A field pilot for extracted water pretreatment was designed.

20 FOSSIL-FUELED POWER PLANTS↗

The Influential Role of Sociocultural Feedbacks on Community-Managed Irrigation System Behaviors During times of Water Stress

Sociohydrological studies use interdisciplinary approaches to explore the complex interactions between physical and social water systems and increase our understanding of emergent and paradoxical system behaviors. The dynamics of community values and social cohesion, however, have received little attention in modeling studies due to quantification challenges. Social structures associated with community-managed irrigation systems around the world, in particular, reflect these communities' experiences with a multitude of natural and social shocks. Using the Valdez acequia (a communally-managed irrigation community in northern New Mexico) as a simulation case study, we evaluate the impact of that community's social structure in governing its responses to water availability stresses posed by climate change. Specifically, a system dynamics model (developed using insights from community stakeholders and multiple disciplines that captures biophysical, socioeconomic, and sociocultural dynamics of acequia systems) was used to generate counterfactual trajectories to explore how the community would behave with streamflow conditions expected under climate change. We found that earlier peak flows, combined with adaptive measures of shifting crop selection, allowed for greater production of higher value crops and fewer people leaving the acequia. The economic benefits were lost, however, if downstream water pressures increased. Even with significant reductions in agricultural profitability, feedbacks associated with community cohesion buffered the community's population and land parcel sizes from more detrimental impacts, indicating the community's resilience under natural and social stresses. In conclusion, continued exploration of social structures is warranted to better understand these systems' responses to stress and identify possible leverage points for strengthening community resilience.

54 ENVIRONMENTAL SCIENCES↗

The Spacecraft Water Impurity Monitor, a Framework for the Next Generation Complete Water Analysis System for Crewed Vehicles Beyond the ISS

The Spacecraft Water Impurity Monitor (SWIM) is a joint collaboration to develop an instrument platform that will perform in-flight measurements and deliver a more complete picture of water quality to decision makers. Eventually, missions to the moon, Mars, and beyond will be equipped with analytical capabilities equaling those found in terrestrial labs. Based on what we know about current and future spacecraft environments, SWIM will seek to provide enhanced analytical capability that enables NASA to confidently send astronauts on distant missions without the possibility of returned water samples. This paper discusses the challenges presented by exploration requirements and the research and development progress toward the goal of a total water analysis system. For organic analysis, one of the analysis technologies that the SWIM team have been developing is a liquid-injection gas chromatograph mass spectrometer system; these systems are the workhorses of analytical chemistry laboratories world-wide. For inorganic analysis, the team is exploring a number of technologies ranging from traditional liquid chromatography technologies (e.g. ion chromatography, capillary electrophoresis) to flight-heritage technology such as ion-specific electrodes.

water monitoring↗

WaterTAP: Tool for analysis of water treatment systems

This presentation describes the Water treatment Technoeconomic Assessment Platform (WaterTAP), an open-source software tool to analyze water treatment trains. The presentation was provided to the NAWI Alliance Fall Meeting on November 29th 2023 and it includes an overview of the tool and a couple of analyses demonstrating its capabilities. The analyses include a technoeconomic assessment of a novel membrane-based technology called low salt rejection reverse osmosis and a brackish water desalination train with pretreatment.

Dudchenko, Alexander↗