A Comparison of Tandem Walk Performance Between Bed Rest Subjects and Astronauts

Astronauts experience a microgravity environment during spaceflight, which results in a central reinterpretation of both vestibular and body axial-loading information by the sensorimotor system. Subjects in bed rest studies lie at 6deg head-down in strict bed rest to simulate the fluid shift and gravity-unloading of the microgravity environment. However, bed rest subjects still sense gravity in the vestibular organs. Therefore, bed rest isolates the axial-unloading component, thus allowing for the direct study of its effects. The Tandem Walk is a standard sensorimotor test of dynamic postural stability. In a previous abstract, we compared performance on a Tandem Walk test between bed rest control subjects, and short- and long-duration astronauts both before and after flight/bed rest using a composite index of performance, called the Tandem Walk Parameter (TWP), that takes into account speed, accuracy, and balance control. This new study extends the previous data set to include bed rest subjects who performed exercise countermeasures. The purpose of this study was to compare performance during the Tandem Walk test between bed rest subjects (with and without exercise), short-duration (Space Shuttle) crewmembers, and long-duration International Space Station (ISS) crewmembers at various time points during their recovery from bed rest or spaceflight.

Miller, Chris↗

Lab-On-Chip Clinorotation System for Live-Cell Microscopy Under Simulated Microgravity

Cells in microgravity are subject to mechanical unloading and changes to the surrounding chemical environment. How these factors jointly influence cellular function is not well understood. We can investigate their role using ground-based analogues to spaceflight, where mechanical unloading is simulated through the time-averaged nullification of gravity. The prevailing method for cellular microgravity simulation is to use fluid-filled containers called clinostats. However, conventional clinostats are not designed for temporally tracking cell response, nor are they able to establish dynamic fluid environments. To address these needs, we developed a Clinorotation Time-lapse Microscopy (CTM) system that accommodates lab-on- chip cell culture devices for visualizing time-dependent alterations to cellular behavior. For the purpose of demonstrating CTM, we present preliminary results showing time-dependent differences in cell area between human mesenchymal stem cells (hMSCs) under modeled microgravity and normal gravity.

Yew, Alvin G.↗

10 GHz YBa2Cu3O7-delta Superconducting Ring Resonators on NdGaO3 Substrates

YBa2Cu3O7-delta thin films were formed on NdGaO3 substrates by laser ablation. Critical temperatures greater than 89 K and critical current densities exceeding 2 x 10(exp.6) A cm(exp.-2) at 77 K were obtained. The microwave performance of films patterned into microstrip ring resonators with gold ground planes was measured. An unloaded quality factor six times larger than a that of a gold resonator of identical geometry was achieved. The unloaded quality factor decreased below 70 K for both the superconducting and gold resonators due to increasing dielectric losses in the substrate. The temperature dependence of the loss tangent of NdGaO3 was extracted from the measurements.

To, H. Y.↗

Skeletal Micro-RNA Responses to Simulated Weightlessness

Astronauts lose bone structure during long-duration spaceflight. These changes are due, in part, to insufficient bone formation by the osteoblast cells. Little is known about the role that small (approximately 22 nucleotides), non-coding micro-RNAs (miRNAs) play in the osteoblast response to microgravity. We hypothesize that osteoblast-lineage cells alter their miRNA status during microgravity exposure, contributing to impaired bone formation during weightlessness. To simulate weightlessness, female mice (C57BL/6, Charles River, 10 weeks of age, n = 7) were hindlimb unloaded up to 12 days. Age-matched and normally ambulating mice served as controls (n=7). To assess the expression of miRNAs in skeletal tissue, the tibia was collected ex vivo and cleaned of soft-tissue and marrow. Total RNA was collected from tibial bone and relative abundance was measured for miRNAs of interest using quantitative real time PCR array looking at 372 unique and well-characterized mature miRNAs using the delta-delta Ct method. Transcripts of interest were normalized to an average of 6 reference RNAs. Preliminary results show that hindlimb unloading decreased the expression of 14 miRNAs to less than 0.5 times that of the control levels and increased the expression of 5 miRNAs relative to the control mice between 1.2-1.5-fold (p less than 0.05, respectively). Using the miRSystem we assessed overlapping target genes predicted to be regulated by multiple members of the 19 differentially expressed miRNAs as well as in silico predicted targets of our individual miRNAs. Our miRsystem results indicated that a number of our differentially expressed miRNAs were regulators of genes related to the Wnt-Beta Catenin pathway-a known regulator of bone health-and, interestingly, the estrogen-mediated cell-cycle regulation pathway, which may indicate that simulated weightlessness modulated systemic hormonal levels or hormonal transduction that additionally contributed to bone loss. We plan to follow up these findings by measuring gene expression of miRNA-regulated genes within these two pathways with the aim of furthering our understanding of the function of miRNAs in the skeletal response to spaceflight.

musculoskeletal system↗

Lab-On-Chip Clinorotation System for Live-Cell Microscopy Under Simulated Microgravity

Cells in microgravity are subject to mechanical unloading and changes to the surrounding chemical environment. How these factors jointly influence cellular function is not well understood. We can investigate their role using ground-based analogues to spaceflight, where mechanical unloading is simulated through the time-averaged nullification of gravity. The prevailing method for cellular microgravity simulation is to use fluid-filled containers called clinostats. However, conventional clinostats are not designed for temporally tracking cell response, nor are they able to establish dynamic fluid environments. To address these needs, we developed a Clinorotation Time-lapse Microscopy (CTM) system that accommodates lab-on- chip cell culture devices for visualizing time-dependent alterations to cellular behavior. For the purpose of demonstrating CTM, we present preliminary results showing time-dependent differences in cell area between human mesenchymal stem cells (hMSCs) under modeled microgravity and normal gravity.

Yew, Alvin G.↗

Regulation of Bone Formation During Disuse by miRNA

Astronauts lose bone structure during long-duration spaceflight. These changes are due, in part, to insufficient bone formation by the osteoblast cells. Little is known about the role that small (approximately 22 nucleotide), non-coding micro-RNAs (miRNAs) play in the osteoblast response to microgravity. We hypothesize that osteoblast-lineage cells alter their miRNA status during microgravity exposure, contributing to impaired bone formation during weightlessness. To simulate weightlessness, female mice (C57BL/6, Charles River, 10 weeks of age, n = 6) were hindlimb unloaded for 12 days. Age-matched and normally ambulating mice served as controls (n=6). To assess the expression of miRNAs in skeletal tissue, the right and left tibia of the mice were collected ex vivo and cleaned of soft-tissue and marrow. Total RNA was collected from tibial bone and relative abundance was measured for miRNAs of interest using quantitative real time PCR array looking at 372 unique and well-characterized mature miRNAs using the delta-delta Ct method. Transcripts of interest were normalized to an average of 6 reference RNAs. Preliminary results show that hindlimb unloading decreased the expression of 14 miRNAs to less than 1.4-2.9X control levels and increased the expression of 5 miRNAs relative to the control mice greater than 1-2-1.5X (p less than 0.05, respectively). Using the miRSystem we assessed overlapping target genes predicted to be regulated by multiple members of the 19 differentially expressed miRNAs as well as in silico predicted targets of our individual miRNAs. Our miRSystem results indicated that a number of our differentially expressed miRNAs were regulators of genes related to the Wnt-Beta Catenin pathway-a known regulator of bone health-and, interestingly, the estrogen-mediated cell-cycle regulation pathway, which may indicate that simulated weightlessness induced systemic hormonal changes that contributed to bone loss. We plan to follow up these findings by measuring gene expression of miRNA-regulated genes within these two pathways with the aim of furthering our understanding of the function of miRNAs in the skeletal response to spaceflight.

bone↗

Femoral Head Bone Loss Following Short and Long-Duration Spaceflight

Exposure to mechanical unloading during spaceflight is known to have significant effects on the musculoskeletal system. Our ongoing studies with the mouse bone model have identified the failure of normal stem cell-based tissue regeneration, in addition to tissue degeneration, as a significant concern for long-duration spaceflight, especially in the mesenchymal and hematopoietic tissue lineages. The 30-day BionM1 and the 37-day Rodent Research 1 (RR1) missions enabled the possibility of studying these effects in long-duration microgravity experiments. We hypothesized that the inhibition of stem cell-based tissue regeneration in short-duration spaceflight would continue during long-duration spaceflight and furthermore would result in significant tissue alterations. MicroCT analysis of BionM1 femurs revealed 31 decrease in bone volume ratio, a 14 decrease in trabecular thickness, and a 20 decrease in trabecular number in the femoral head of space-flown mice. Furthermore, high-resolution MicroCT and immunohistochemical analysis of spaceflight tissues revealed a severe disruption of the epiphyseal boundary, resulting in endochondral ossification of the femoral head and perforation of articular cartilage by bone. This suggests that spaceflight in microgravity may cause rapid induction of an aging-like phenotype with signs of osteoarthritic disease in the hip joint. However, mice from RR1 exhibited significant bone loss in the femoral head but did not exhibit the severe aging and disease-like phenotype observed during BionM1. This may be due to increased physical activity in the RH hardware. Immunohistochemical analysis of the epiphyseal plate and investigation of cellular proliferation and differentiation pathways within the marrow compartment and whole bone tissue is currently being conducted to determine alterations in stem cell-based tissue regeneration between these experiments. Our results show that the observed inhibition of stem cell-based tissue regeneration persists during long-duration spaceflight. Furthermore, spaceflight femurs from BionM1 indicate onset of an accelerated aging-like phenotype with signs of osteoarthritic disease shown by disruption of the epiphyseal boundary and endochondral ossification. These effects are likely caused by a failure of stem cells to regenerate degraded tissues and may have significant implications for bone and cartilage health following extensive periods of mechanical unloading during long-duration spaceflight.

stem cells↗

Change in Mouse Bone Turnover in Response to Microgravity on RR-1

Mechanical unloading during spaceflight is known to adversely affect mammalian physiology. Our previous studies using the Animal Enclosure Module on short duration Shuttle missions enabled us to identify a deficit in stem cell based-tissue regeneration as being a significant concern for long-duration spaceflight. Specifically, we found that mechanical unloading in microgravity resulted in inhibition of differentiation of mesenchymal and hematopoietic stem cells in the bone marrow compartment. Also, we observed overexpression of a cell cycle arrest molecule, CDKN1ap21, in osteoprecursor cells on the bone surface, chondroprogenitors in the articular cartilage, and in myofibers attached to bone tissue. Specifically in bone tissue during both short (15-day) and long (30-day) microgravity experiments, we observed significant loss of bone tissue and structure in both the pelvis and the femur. After 15-days of microgravity on STS-131, pelvic ischium displayed a 6.23 decrease in bone fraction (p0.005) and 11.91 decrease in bone thickness (p0.002). Furthermore, during long-duration spaceflight we observed onset of an accelerated aging-like phenotype and osteoarthritic disease state indicating that stem cells within the bone tissue fail to repair and regenerate tissues in a normal manner, leading to drastic tissue alterations in response to microgravity. The Rodent Research Hardware System provides the capability to investigate these effects during long-duration experiments on the International Space Station. During the Rodent Research-1 mission 10 16-week-old female C57Bl6J mice were exposed to 37-days of microgravity. All flight animals were euthanized and frozen on orbit for future dissection. Ground (n10) and vivarium controls (n10) were housed and processed to match the flight animal timeline. During this study we collected pelvis, femur, and tibia from all animal groups to test the hypothesis that stem cell-based tissue regeneration is significantly altered after 37-days of spaceflight. To do this, we will analyze differences in bone morphometric parameters using MicroCT. The pelvis, femur, and tibia are key in supporting and distributing weight under normal conditions. Therefore, we expect to see altered remodeling in flight animals in response to microgravity with respect to ground controls. In combination with histomorphometry, these results will help elucidate the complex mechanisms underlying bone tissue maintenance and stem cell regeneration.

bone↗

Changes in Mouse Bone Turnover in Response to Microgravity

Mechanical unloading during spaceflight is known to adversely affect mammalian physiology. Our previous studies using the Animal Enclosure Module on short duration Shuttle missions enabled us to identify a deficit in stem cell based-tissue regeneration as being a significant concern for long-duration spaceflight. Specifically, we found that mechanical unloading in microgravity resulted in inhibition of differentiation of mesenchymal and hematopoietic stem cells in the bone marrow compartment. Also, we observed overexpression of a cell cycle arrest molecule, CDKN1a/p21, in osteoprecursor cells on the bone surface, chondroprogenitors in the articular cartilage, and in myofibers attached to bone tissue. Specifically in bone tissue during both short (15-day) and long (30-day) microgravity experiments, we observed significant loss of bone tissue and structure in both the pelvis and the femur. After 15-days of microgravity on STS-131, pelvic ischium displayed a 6.23% decrease in bone fraction (p=0.005) and 11.91% decrease in bone thickness (p=0.002). Furthermore, during long-duration spaceflight we observed onset of an accelerated aging-like phenotype and osteoarthritic disease state indicating that stem cells within the bone tissue fail to repair and regenerate tissues in a normal manner, leading to drastic tissue alterations in response to microgravity. The Rodent Research Hardware System provides the capability to investigate these effects during long-duration experiments on the International Space Station. During the Rodent Research-1 mission 10 16-week-old female C57Bl/6J mice were exposed to 37-days of microgravity. All flight animals were euthanized and frozen on orbit for future dissection. Ground (n=10) and vivarium controls (n=10) were housed and processed to match the flight animal timeline. During this study we collected pelvis, femur, and tibia from all animal groups to test the hypothesis that stem cell-based tissue regeneration is significantly altered after 37-days of spaceflight. To do this, we will analyze differences in bone morphometric parameters using MicroCT. The pelvis, femur, and tibia are key in supporting and distributing weight under normal conditions. Therefore, we expect to see altered remodeling in flight animals in response to microgravity with respect to ground controls. In combination with histomorphometry, these results will help elucidate the complex mechanisms underlying bone tissue maintenance and stem cell regeneration.

microgravity↗

Femoral Head Bone Loss Following Short and Long-Duration Spaceflight

Exposure to mechanical unloading during spaceflight is known to have significant effects on the musculoskeletal system. Our ongoing studies with the mouse bone model have identified the failure of normal stem cell-based tissue regeneration, in addition to tissue degeneration, as a significant concern for long-duration spaceflight, especially in the mesenchymal and hematopoietic tissue lineages. The 30-day BionM1 and the 37-day Rodent Research 1 (RR1) missions enabled the possibility of studying these effects in long-duration microgravity experiments. We hypothesized that the inhibition of stem cell-based tissue regeneration in short-duration spaceflight would continue during long-duration spaceflight and furthermore would result in significant tissue alterations. MicroCT analysis of BionM1 femurs revealed 31% decrease in bone volume ratio, a 14% decrease in trabecular thickness, and a 20% decrease in trabecular number in the femoral head of space-flown mice. Furthermore, high-resolution MicroCT and immunohistochemical analysis of spaceflight tissues revealed a severe disruption of the epiphyseal boundary, resulting in endochondral ossification of the femoral head and perforation of articular cartilage by bone. This suggests that spaceflight in microgravity may cause rapid induction of an aging-like phenotype with signs of osteoarthritic disease in the hip joint. However, mice from RR1 exhibited significant bone loss in the femoral head but did not exhibit the severe aging and disease-like phenotype observed during BionM1.This may be due to increased physical activity in the RH hardware. Immunohistochemical analysis of the epiphyseal plate and investigation of cellular proliferation and differentiation pathways within the marrow compartment and whole bone tissue is currently being conducted to determine alterations in stem cell-based tissue regeneration between these experiments. Our results show that the observed inhibition of stem cell-based tissue regeneration persists during long-duration spaceflight. Furthermore, spaceflight femurs from BionM1 indicate onset of an accelerated aging-like phenotype with signs of osteoarthritic disease shown by disruption of the epiphyseal boundary and endochondral ossification. These effects are likely caused by a failure of stem cells to regenerate degraded tissues and may have significant implications for bone and cartilage health following extensive periods of mechanical unloading during long-duration spaceflight.

microgravity↗

Simulated Space Radiation and Weightlessness: Vascular-Bone Coupling Mechanisms to Preserve Skeletal Health

We examined experimentally the effects of radiation and/or simulated weightlessness by hindlimb unloading on bone and blood vessel function either after a short period or at a later time after transient exposures in adult male, C57Bl6J mice. In sum, recent findings from our studies show that in the short term, ionizing radiation and simulate weightlessness cause greater deficits in blood vessels when combined compared to either challenge alone. In the long term, heavy ion radiation, but not unloading, can lead to persistent, adverse consequences for bone and vessel function, possibly due to oxidative stress-related pathways.

microgravity↗

The Effects of Propellant Slosh Dynamics on the Solar Dynamics Observatory

The Solar Dynamics Observatory (SDO) mission, which is part of the Living With a Star program, was successfully launched and deployed from its Atlas V launch vehicle on February 11, 2010. SDO is an Explorer-class mission now operating in a geosynchronous orbit (GEO). The basic mission is to observe the Sun for a very high percentage of the 5-year mission (10-year goal) with long stretches of uninterrupted observations and with constant, high-data-rate transmission to a dedicated ground station located in White Sands, New Mexico. A significant portion of SDO's launch mass was propellant, contained in two large tanks. To ensure performance with this level of propellant, a slosh analysis was performed. This paper provides an overview of the SDO slosh analysis, the on-orbit experience, and the lessons learned. SDO is a three-axis controlled, single fault tolerant spacecraft. The attitude sensor complement includes sixteen coarse Sun sensors, a digital Sun sensor, three two-axis inertial reference units, two star trackers, and four guide telescopes. Attitude actuation is performed either using four reaction wheels or eight thrusters, depending on the control mode, along with single main engine which nominally provides velocity-change thrust. The attitude control software has five nominal control modes: three wheel-based modes and two thruster-based modes. A wheel-based Safehold running in the Attitude Control Electronics (ACE) box improves the robustness of the system as a whole. All six modes are designed on the same basic proportional-integral-derivative attitude error structure, with more robust modes setting their integral gains to zero. To achieve and maintain a geosynchronous orbit for a 2974-kilogram spacecraft in a cost effective manner, the SDO team designed a high-efficiency propulsive system. This bi-propellant design includes a 100-pound-force main engine and eight 5-pound-force attitude control thrusters. The main engine provides high specific impulse for the maneuvers to attain GEO, while the smaller Attitude Control System (ACS) thrusters manage the disturbance torques of the larger main engine and provide the capability for much smaller orbit adjustment burns. SDO's large solar profile produces a large solar torque disturbance and momentum buildup. This buildup drives the frequency of momentum unloads via ACS thrusters. SDO requires 1409 kilograms (which is approximately half the launch mass) of propellant to achieve and maintain the GEO orbit while performing the momentum unloads for 10 years.

Mason, Paul↗

Aging and Spaceflight: Catalase Targeted to Mitochondria Alters Skeletal Structure and Responses to Musculoskeletal Disuse

Microgravity and ionizing radiation in the spaceflight environment pose multiple challenges to homeostasis and may contribute to cellular stress. Effects may include increased generation of reactive oxygen species (ROS), DNA damage and repair error, cell cycle arrest, cell senescence or death. Our central hypothesis is that prolonged exposure to the spaceflight environment leads to excess production of ROS and oxidative damage, culminating in accelerated tissue degeneration which resembles aging. The main goal of this project is to determine the importance of cellular redox defense for physiological adaptations and tissue degeneration in the space environment. To accomplish this, we will use both wildtype (WT) mice and a well-established, genetically-engineered animal model (mCAT mice) which displays extended lifespan (Schriner et al. 2005). The animal model selected to test these ideas is engineered to quench ROS in mitochondria by targeted over-expression of the human catalase gene to the mitochondrial matrix. We showed previously that mCAT mice express the catalase transgene in skeletal tissues, bone forming osteoblasts, and bone resorbing osteoclasts. In addition, mCAT mice also display increased catalase activity in bone. Our findings revealed that exposure of adult, male, C57Bl/6J mice to simulated spaceflight (hindlimb unloading and gamma radiation) led to an increase in markers of oxidative damage (malondialdehyde, 4-hydroxynonenol) in skeletal tissue of WT mice but not mCAT mice. To extend our hypothesis to other, spaceflight-relevant tissues, we are performing a ground-based study simulating 30 days of spaceflight by hindlimb unloading to determine potential protective effects of mitochondrial catalase activity on aging of multiple tissues (cardiovascular, nervous and skeletal).

transgenic mice↗

Zoledronate Prevents Simulated Weightlessness-Induced Bone Loss in the Cancellous Compartment While Blunting the Efficacy of a Mechanical Loading Countermeasure

Astronauts using high-force resistance training while weightless show a high-turnover remodeling state within the skeletal system, with resorption and formation biomarkers being elevated. One countermeasure for the skeletal health of astronauts includes an antiresorptive of the bisphosphonate (BP) drug class. We asked, does the combination of an anti-resorptive and high-force exercise during weightlessness have negative effects on bone remodeling and strength? In this study, we developed an integrated model to mimic the mechanical strain of exercise via cyclical loading (CL) in mice treated with the BP Zoledronate (ZOL) combined with hind limb unloading (HU) to simulate weightlessness. We hypothesized that ZOL prevents structural degradation from simulated weightlessness and that CL and ZOL interact to render CL less effective. Thirty-two C57BL/6 mice (male, 16 weeks old, n=8/group) were exposed to 3 weeks of either HU or normal ambulation (NA). Cohorts of mice received one subcutaneous injection of ZOL (45μg/kg), or saline vehicle (VEH), prior to the start of HU. The right tibia was axially compressed in vivo 60x/day to 9N (+1200μstrain on the periosteal surface) and repeated 3x/week during HU. Left tibiae served as a within subject, non-compressed control. Ex vivo μCT was performed on all subjects to determine cancellous and cortical architectural parameters. Static and dynamic histomorphometry were carried out for the left and right tibiae to determine osteoclast- and osteoblast relevant surfaces. Further, micro damage was assessed in select groups by basic-fuchsin staining to test whether CL had an effect. For all assays, a multivariate (2x2x2) ANCOVA model was used to account for body weight changes. Additionally, for the tibiae, we incorporated a random effect for the subject (hence, a mixed model) to account for observations of both left and right tibiae within each subject. P < 0.05 was considered significant. In the cancellous compartment of the proximal tibial metaphysis, we observed a main effect from each independent variable, as determined by structural and histomorphometric assays. Specifically, as expected, ZOL showed an increase in the cancellous bone volume to total volume fraction (BV/TV, +32%) and trabecular number (+18%) compared to the VEH. As expected, ZOL decreased osteoclast surface (OC/BS) by -45% compared to VEH. Surprisingly, ZOL reduced mineralizing surface (MS/BS) and bone formation rate (BFR), indicators of osteoblast activity, by -40% and -54%, respectively, compared to VEH. Altogether, ZOL-treated mice displayed a low turnover state of remodeling in the metaphysis. In the context of skeletal aging, we speculate that ZOL prevented age-related cancellous strut loss during the experiment. As a main effect, as expected, HU decreased BV/TV by - 31% via reductions in both trabecular thickness (-11%) and number (-22%) compared to NA controls. Additionally, HU decreased MS/BS by -38% and bone formation rate (BFR) by -50% compared to NA controls. Altogether, these data are consistent with structural degradation resulting from imbalanced remodeling that favors resorption. As a main effect, CL increased BV/TV by +15% via increased trabecular thickness (+12%) compared to the noncompressed limb. As expected, CL increased MS/BS (+20%) and BFR (+24%), indicating osteoblast mineralization contributed to bone gains. These data show that CL provided an anabolic stimulus to the cancellous tissue. We observed unique interactions in ZOL*CL and HU*CL. First, ZOL prevented CL-induced increases in BV/TV and trabecular number, as compared to VEH. In the context of skeletal aging, these data suggest no added benefit from CL in the ZOL-treated mice. Interestingly, no microdamage was observed in mice that were unloaded and treated with ZOL (independent of CL). Secondly, HU prevented CL-induced increases in BFR, as compared to NA controls. These data suggest that either exercise is less effective or the kinetics of formation are slower during simulated weightlessness. Osteoclast surface was unchanged by either treatment. Thus, in contrast to exercising astronauts, these data do not suggest a high-turnover state in the metaphysis. To assess mechanical properties as a function of HU or ZOL, we tested the left femur in three-point bending ex vivo. As expected, HU decreased stiffness (-30%) compared to NA, and ZOL increased stiffness compared to VEH (+28%). Interestingly, HU increased the post-yield displacement, related to collagenous tensile loading, compared to NA (+20%). ZOL increased yield force (+11%) and ultimate force (+17%), which seems to explain the significant effect of ZOL increasing total energy (work-to-fracture, +15%), while not affecting the post yield displacement. Taken together, ZOL did not have detrimental affect on mechanical properties. Our integrated model simulates the combination of weightlessness, exercise-induced mechanical strain, and anti-resorptive treatment that astronauts experience during space missions. We conclude that Zoledronate was an effective countermeasure against weightlessness-induced bone loss, though zoledronate, as well as weightlessness, rendered exercise-related mechanical loading less effective.

bone↗

Bone and Cartilage Degeneration in Mice Following Long-Duration Spaceflight: The Role of Bone Marrow Stem Cells

The detrimental effects of mechanical unloading in microgravity, including the musculo-skeletal system, are well documented. However, the effects of mechanical unloading on joint health and the interaction between bone and cartilage specifically, are less well known. Our ongoing studies with the mouse bone model have identified the failure of normal stem cell-based tissue regeneration, in addition to tissue degeneration, as a significant concern for long-duration spaceflight, especially in the mesenchymal and hematopoietic tissue lineages. Furthermore, we have identified the cell cycle arrest molecule, CDKN1ap21, as specifically up-regulated during spaceflight exposure and localized to osteoprecursors on the bone surface and chondroprogenitors in articular cartilage that are both required for normal tissue regeneration. The 30-day BionM1 and 37-day Rodent Research 1 (RR1) missions enabled the possibility of studying these effects in long-duration microgravity experiments. We hypothesized that the inhibition of stem cell-based tissue regeneration in short-duration spaceflight would continue during long-duration spaceflight resulting in significant tissue alterations and we specifically studied the hip joint (pelvis and proximal femur) to elucidate these effects. To test this hypothesis we analyzed bone and bone marrow stem cells using techniques including high-resolution Microcomputed Tomography (MicroCT), in-vivo differentiation and migration assays, and whole transcriptome expression profiling. We found that exposure to spaceflight for 30 days results in a significant decrease in bone volume fraction (-31), trabecular thickness (-14) and trabecular number (-20). Similar decrements in bone volume fraction (-27), trabecular number (-13) and trabecular thickness (-17) were found in female mice exposed to 37 days spaceflight. Furthermore, high-resolution MicroCT and immunohistochemical analysis of spaceflight tissues revealed a severe disruption of the epiphyseal boundary, resulting in endochondral ossification of the femoral head and perforation of articular cartilage by bone. This suggests that spaceflight in microgravity may cause rapid induction of an aging-like phenotype with signs of osteoarthritic disease in the hip joint. Microarray analysis also revealed that the top pathways altered during spaceflight include activation of matrix metalloproteinases, oxidative stress signaling and inflammation in both whole bone tissue and isolated bone marrow stem cells. In conclusion, the observed inhibition of stem cell-based tissue regeneration persists during long-duration spaceflight. Furthermore, spaceflight mice exhibit disruption of the epiphyseal boundary and endochondral ossification of the femoral head, and an inhibition of stem cell based tissue regeneration, which, taken together, may indicate onset of an accelerated aging phenotype with signs of osteoarthritic disease.

Cartilage↗

Restore-L Satellite Servicing Internship Final Report

An experiment was conducted to determine whether a sample of shorter flexible metal hoses could sustain tensile loads of up to 200 lbf and continue to meet the minimum mission requirements. The purpose of this experiment was to determine if tension loads during the processing of the hoses compromise performance. With this information, it will be decided whether the flight flex-hose manufacturer should proceed with the testing of the full-scale flex-hoses. To reduce the time and funding required for this test, a test fixture was designed and assembled in the Engineering Development & Operations (EDO) test facility. In this test fixture, two Engineering Development Unit (EDU) flex-hoses were loaded with free floating weights up to 350 lbf. A load of 200 lbf equates to the maximum expected loading with a margin of safety, thus all data recorded after 200 lbf was purely for reference. Measurements were taken using a tape measure and a custom datum measurement system to record the loaded and unloaded length of each flex-hose at various loads. Any permanent stretching beyond a 1/8th of an inch was indicative of inelastic yielding. The loading of each flex-hose was done with an initial weight 80 lbf and was increased to 100 lbf. Additional loading up to 350 lbf was done by 50 lbf increments thereafter. During the performance of the test, slippage occurred in the mounting of the flex-hoses in the test fixture. The first slippage occurred during the testing of the first flex-hose due to the collar of the flex-hose slipping within the collet of the top Kellem. As a result, the first flex-hose test was terminated early to modify the fixture. Due to the flex-hose not inelastically yielding, the test was repeated on the first flex hose. This test resulted in another instance of slippage in the upper collar of the Kellem due to tape interfering with the securing of a collet around the collar of the flex-hose. The test was then continued with one more slippage of the flex-hose within the collet of the bottom Kellem. Preventive measures were taken for future slippage, and the second hose remained secure during testing.Once the tests were concluded, the elongation of each hose was analyzed for inelastic yielding. Both flex-hoses stretched a measurable and repeatable amount under loading, however, this stretching was recovered once each hose was unloaded. As a result, both EDU flex-hoses did not experience any inelastic yielding during the tension testing. Once received, one additional flex-hose will be tested for yielding, but at the time of this paper, the recommendation is to proceed with testing of the full-scale flex-hoses at the flex-hose manufacturer.

Dziekan, Joseph↗

Simulated Space Radiation and Weightlessness: Vascular-Bone Coupling Mechanisms to Preserve Skeletal Health

We examined experimentally the effects of radiation andor simulated weightlessness by hindlimb unloading on bone and blood vessel function either after a short period or at a later time after transient exposures in adult male, C57Bl6J mice. In sum, recent findings from our studies show that in the short term, ionizing radiation and simulate weightlessness cause greater deficits in blood vessels when combined compared to either challenge alone. In the long term, heavy ion radiation, but not unloading, can lead to persistent, adverse consequences for bone and vessel function, possibly due to oxidative stress-related pathways.

Microgravity↗

Functional Task Tests in Partial Gravity During Parabolic Flight

BACKGROUND Critical mission tasks that are required by crews immediately after landing on a planetary surface are seat egress, jump, and walk. To be able to define an effective and comprehensive countermeasure strategy for preserving crew performance during exploration-class missions, there is a need to understand how these functional tasks are actually performed in partial gravity such as on the Moon or Mars. We propose to study the performance in the execution of these tasks during the partial gravity and hypergravity phases of parabolic flight. These tasks will be completed using the same equipment and procedures as the Standard Measures Sensorimotor protocol, which is performed by astronauts returning from spaceflight and by ground-based subjects after prolonged axial body unloading during bed rest. HYPOTHESIS We hypothesize that partial gravity during parabolic flight will cause acute changes in vestibular, proprioceptive, and sensorimotor functions, and these changes will impact the performance of mission critical tasks such as standing, walking, and jumping. The largest changes in performance are expected at the lowest gravity level (0.25g) because subjects will no longer be able to use the gravitational reference for the perception of vertical. Ultimately, this information could be used to assess performance risks and inform the design of countermeasures for NASA exploration-class human missions. METHODS Twelve subjects will be tested during three flights of 30 parabolas, including 10 parabolas at 0.25g, 10 parabolas at 0.5g and 10 parabolas at 0.75g. Subject also will perform tests in 1g between parabolas and in hypergravity (1.8g) during the pull-out phases. Subjects will perform the same tasks as those tested on astronauts returning from spaceflight: sit-to-stand and obstacle walk, tandem walk, jump down, and recovery from fall. Measurements will include: (a) the time for the subject to complete the test (sit-to-stand and obstacle walk, recovery from fall); (b) the time elapsed between the start of motion and the stabilization of upright posture (recovery from fall, jump down); (c) the mean sway speed during quiet standing (recovery from fall, jump down); (d) changes in heart rate and blood pressure (recovery from fall); (e) the percentage of correct steps and torso acceleration (tandem walk); and (f) the severity of motion sickness symptoms. RELEVANCE Although gravitational dose-response curves have been obtained for some biochemical systems in animals, these dose-responses are unknown for most human physiologic systems. Our study will compare the outcomes of 5 functional task tests in 0.25g, 0.5g, 0.75g, 1g, and 1.8g with those previously obtained in ground-based subjects after prolonged axial body unloading and in astronauts immediately after spaceflight. This comparison will help understanding the true extent of functional task performance deficits in partial gravity. The dose-response relationship between gravity level and task performance decrement also will help determining the gravity threshold for these functional tasks. ACKNOWLEDGEMENT This work is supported by the NASA’s Human Research Program Human Health Countermeasures Element

Gilles Clement↗