Engineering Papers⌕ Search

SEARCH · Engineering Papers

Results for “Trace gas analysis”

Search indexed NASA NTRS and DOE OSTI research on propulsion, heat transfer, battery materials and energy systems. Follow report and document links to the original sources.

Quote a phrase for an exact phrase match. Source license links do not imply unrestricted reuse.

421 records · Page 24

Beagle 2: The Next Exobiology Mission to Mars

Beagle 2 is a 60 kg probe (with a 30 kg lander) developed in the United Kingdom for inclusion on the European Space Agency's 2003 Mars Express. Beagle 2 will deliver to the Martian surface a payload which consists of a high percentage of science instruments to landed spacecraft mass. Beagle 2 will be launched in June, 2003 with Mars Express on a Soyuz-Fregat rocket from the Baikonur Cosmodrome in Kazakhstan. Beagle 2 will land on Mars on December 26, 2003 in the Isidis Planitia basin (approximately 10 degrees N and 275 degrees W), a large sedimentary basin that overlies the boundary between ancient highlands and northern plains. Isidis Planitia, the third largest basin on Mars, which is possibly filled with sediment deposited at the bottom of long-standing lakes or seas, offers an ideal environment for preserving traces of life. Beagle 2 was developed to search for organic material and other volatiles on and below the surface of Mars in addition to the study of the inorganic chemistry and mineralogy. Beagle 2 will utilize a mechanical mole and grinder to obtain samples from below the surface, under rocks and inside rocks. A pair of stereo cameras will image the landing site along with a microscope for examination of surface and rock samples. Analyses will include both rock and soil samples at various wavelengths, X-ray spectrometer and Mossbauer spectrometer as well as a search for organics and other light element species (e.g. carbonates and water) and measurement of their isotopic compositions. Beagle 2 has as its focus the goal of establishing whether evidence for life existed in the past on Mars at the Isidis Planitia site or at least establishing if the conditions were ever suitable. Carbonates and organic components were first recognized as existing on Mars when they were found in the Martian meteorite Nakhla. Romanek et al showed the carbonates in ALH84001 were formed at low temperatures. McKay et al noted possible evidence of early life on Mars within the ALH84001 meteorite. Thomas-Keprta et al showed the magnetite biomarkers in ALH84001's carbonates are indistinguishable from those formed by magnetotactic bacteria found on Earth. Gibson et al showed there was significant evidence for liquid water and biogenic products present on Mars across a 3.9 billion year period. A mechanical arm (PAW) operates from the lander and is used for science operations along with sample acquisition. Instruments attached to the PAW include: stereo cameras, Mossbauer instrument, X-ray fluorescence instrument, microscope, environmental sensors, rock corer/grinder, a spoon, mirror, brushes, a mole attachment for acquisition of subsurface to depths of 1 to 2 meters and an illumination device. Each camera has 14 filters which have been optimized for mineralogy composition, dust and water vapor detection. The microscope's camera is designed for viewing the size and shape of dust particles, rock surfaces, microfossils, and characteristics of the samples prior to introduction into the gas analysis package (GAP). The camera has a resolution of 4 microns/pixel, features four color capability (red, green, blue and UV (ultraviolet) fluoresence), a depth of focus of 40 micrometers and translation stage of +3 millimeters. The heart of the Beagle 2's life detection package is the gas analysis package (GAP), which consists of a mass spectrometer with collectors at fixed masses for precise isotopic ratio measurements and voltage scanning for spectral analysis. Primary aim of the GAP is to search for the presence of bulk constituents, individual species, and isotopic fractionations for both extinct and extent life along with studying the low-temperature geochemistry of the hydrogen, carbon, nitrogen and oxygen components on Mars from both the surface and atmosphere. GAP is a magnetic sector mass spectrometer with the range of 1 to 140 amu which can be operated in both the static and dynamic modes. A triple Faraday collector array will be used for C, N and O ratios along with a double Faraday array for H/D. Pulse counting electron multiplier will be utilized for noble gases and selected organics. Anticipated detection limits are at the picomole level for operation in the static mode of operation and high precision isotopic measurements will be made in the dynamic mode. Sample processing and preparation system consists of reaction vessels along with references. Sample ovens capable of being heated are attached to the manifold for sample combustion. Surface, subsurface materials and interior rock specimens will be combusted in pure oxygen gas at various temperature intervals to release organic matter and volatiles. Combustion process will permit detection of all forms and all atoms of carbon present in the samples. A chemical processing system is capable of a variety of conversion reactions. Gases are manipulated either by cryogenic or chemical reactions and passed through the gas handling portion of the vacuum system. There are two modes of operation: quantitative analysis and precise isotopic measurements. Additional information is contained in the original extended abstract.

Gibson, Everett K., Jr.↗

The Search for Chiral Asymmetry as a Potential Biosignature in Samples from Mars

The search for evidence of extraterrestrial life in our solar system has been guided by our under-standing of terrestrial biology and its associated biosignatures. The observed homochirality in all life on Earth, that is, the predominance of “left-handed” or L-amino acids and “right-handed” or D-sugars, is a unique property of life that is crucial for molecular recognition, enzymatic function, information storage and structure, and is thought to be a prerequisite for the origin or early evolution of life. Therefore, the detection of L- or D-excesses of chiral amino acids or sugars could be a powerful indicator of extant or extinct life on Mars or other habitable environments in our solar system. However, studies of primitive meteorites have revealed that they contain extraterrestrial amino acids and sugar acids with large enantiomeric excesses (60% and higher) that resulted from non-biological processes [1], complicating the use of chiral asymmetry by itself as a definitive biosignature. The exploration of habitable environments on Mars, including an assessment of the preservation potential for complex organics of either abiotic or biological origin, is an objective of both current and future Mars missions. Now with the unambiguous detection of indigenous organic matter in sedimentary rocks by the Sample Analysis at Mars (SAM) instrument suite on Mars [2-5], NASA’s Curiosity rover has found evidence of the preservation of potential chemical biosignatures in the martian near surface. Although amino acids have not yet been identified by in situ measurements on Mars [5], indigenous achiral amino acids have been identified in one martian meteorite [6]. It is expected that amino acid racemization would be very slow and any chiral or isotopic signatures from an extinct martian biota could be preserved for billions of years, given the extremely cold and dry surface conditions [7]. The ESA/Roscosmos ExoMars mission scheduled for launch next year includes the Rosalind Franklin rover designed to acquire samples from a depth of ~2 m and deliver them to a suite of instruments, including the Mars Organic Molecule Analyzer (MOMA). The MOMA instrument contains a wet chemistry experiment designed specifically for the detection of amino acids and measurement of their enantiomeric compositions [8]. The complexity and limited duration of spaceflight operations, and the known analytical challenges associated with in situ extraction and characterization of trace reduced organic com-pounds in ancient rocks, make it challenging to determine the origins of martian organic matter found to date. Coordinated state-of-the-art laboratory measurements of returned samples from Mars that include spatially resolved chemical, mineralogical, bulk and molecule-specific isotopic, and enantiomeric measurements will be required to firmly establish whether the complex organic matter detected on Mars derives from bio-tic or abiotic processes. Ultimately, Mars Sample Return of rock cores collected by NASA’s Perseverance rover may be our best chance of identifying chemical biosignatures, including any chiral amino acid asymmetry resulting from a past or present martian biota, if one ever existed on Mars. Here we review our current knowledge of the distributions, and enantiomeric and isotopic com-positions of amino acids found in meteorites compared to terrestrial biochemistry. We also propose a set of measurement criteria that should be used to help establish the sources of any amino acids detected in samples returned from Mars using state-of-the-art gas and liquid chromatography mass spectrometry techniques [1].

D P Glavin↗

Airborne flux measurements of ammonia over the Southern Great Plains using chemical ionization mass spectrometry

Ammonia (NH 3 ) is an abundant trace gas in the atmosphere and an important player in atmospheric chemistry, aerosol formation and the atmosphere-surface exchange of nitrogen. It is recognized as a major source of aerosol pollution, and it may limit the formation of cloud nuclei in remote or cold parts of the atmosphere. For soil and plants, NH 3 -mediated nitrogen can act as a harmful pollutant or as a desirable nutrient, mostly in natural and agricultural settings, respectively. Agriculture is also the main source of atmospheric NH 3 via volatilization from fertilizers and manure processing in livestock farming. The accurate determination of NH 3 emission rates remains a challenge, partly due to the propensity of NH 3 to interact with instrument surfaces leading to high detection limits and slow response times. In this paper, we present a new method for quantifying ambient NH 3 , using chemical ionization mass spectrometry (CIMS) with deuterated benzene cations as reagents. The setup aimed at limiting sample-surface interactions and achieved a 1-σ precision of 10–20 pptv and an immediate 1/e response rate < 0.4 s, which compares favorably to the existing state of the art. The sensitivity exhibited an inverse humidity dependence, in particular in relatively dry conditions. Background of up to 10 % of the total signal required consideration as well, as it responded on the order of a few minutes. To showcase the method’s capabilities, we quantified NH3 mixing ratios from measurements obtained during deployment on a Gulfstream I aircraft during the HI-SCALE (Holistic Interactions of Shallow Clouds, Aerosols and Land Ecosystems) field campaign in rural Oklahoma during May 2016. Typical mixing ratios were 1–10 parts per billion by volume (ppbv) for the boundary layer and 0.1–1 ppbv in the lower free troposphere. Sharp plumes of up to 10s of ppbv of NH3 were encountered as well. We identified two of their sources as a large fertilizer plant and a cattle farm, and our mixing ratio measurements yielded upper bounds of 350 ± 50 and 0.6 kg NH 3 h –1 for their respective momentary source rates. The fast response of the CIMS also allowed us to derive vertical NH 3 fluxes within the turbulent boundary layer via eddy covariance, for which we chiefly used the continuous wavelet transform technique. As expected for a region dominated by agriculture, we observed predominantly upward fluxes, implying net NH 3 emissions from surface. The corresponding analysis focused on the most suitable flight, which contained two straight-and-level legs at ~300 m above ground. We derived NH 3 fluxes between –4 and 18 mol km –2 h –1 for these legs, at an effective spatial resolution of 1–2 km. The analysis demonstrated how flux measurements benefit from suitably arranged flight tracks with sufficiently long straight-and-level legs, and explores the detrimental effect of measurement discontinuities. Following flux footprint estimations, comparison to the NH 3 area emissions inventory provided by the US Environmental Protection Agency indicated overall agreement, but also the absence of some sources, for instance the identified cattle farm. Our study concludes that high-precision CIMS measurements are a powerful tool for in-situ measurements of ambient NH 3 mixing ratios, and even allow for the airborne mapping of the air-surface exchange of NH 3 .

54 ENVIRONMENTAL SCIENCES↗

Simulation of Radon-222 with the GEOS-Chem Global Model: Emissions, Seasonality, and Convective Transport

Radon-222 (Rn-222) is a short-lived radioactive gas naturally emitted from land surfaces and has long been used to assess convective transport in atmospheric models. In this study, we simulate Rn-222 using the GEOS-Chem chemical transport model to improve our understanding of Rn-222 emissions and surface concentration seasonality and characterize convective transport associated with two Goddard Earth Observing System (GEOS) meteorological products, the Modern-Era Retrospective analysis for Research and Applications (MERRA) and GEOS Forward Processing (GEOS-FP). We evaluate four global Rn-222 emission scenarios by comparing model results with observations at 51 surface sites. The default emission scenario in GEOS-Chem yields a moderate agreement with surface observations globally (68.9 % of data within a factor of 2) and a large underestimate of winter surface Rn-222 concentrations at Northern Hemisphere midlatitudes and high latitudes due to an oversimplified formulation of Rn-222 emission fluxes (1 atom cm−2 s−1 over land with a reduction by a factor of 3 under freezing conditions). We compose a new global Rn-222 emission scenario based on Zhang et al. (2011) and demonstrate its potential to improve simulated surface Rn-222 concentrations and seasonality. The regional components of this scenario include spatially and temporally varying emission fluxes derived from previous measurements of soil radium content and soil exhalation models, which are key factors in determining Rn-222 emission flux rates. However, large model underestimates of surface Rn-222 concentrations still exist in Asia, suggesting unusually high regional Rn-222 emissions. We therefore propose a conservative upscaling factor of 1.2 for Rn-222 emission fluxes in China, which was also constrained by observed deposition fluxes of 210Pb (a progeny of Rn-222). With this modification, the model shows better agreement with observations in Europe and North America (> 80 % of data within a factor of 2) and reasonable agreement in Asia (close to 70 %). Further constraints on Rn-222 emissions would require additional concentration and emission flux observations in the central United States, Canada, Africa, and Asia. We also compare and assess convective transport in model simulations driven by MERRA and GEOS-FP using observed Rn-222 vertical profiles in northern midlatitude summer and from three short-term airborne campaigns. While simulations with both GEOS products are able to capture the observed vertical gradient of Rn-222 concentrations in the lower troposphere (0–4 km), neither correctly represents the level of convective detrainment, resulting in biases in the middle and upper troposphere. Compared with GEOS-FP, MERRA leads to stronger convective transport of Rn-222, which is partially compensated for by its weaker large-scale vertical advection, resulting in similar global vertical distributions of Rn-222 concentrations between the two simulations. This has important implications for using chemical transport models to interpret the transport of other trace species when these GEOS products are used as driving meteorology.

Bo Zhang↗

Trend Detection of Atmospheric Time Series: Incorporating Appropriate Uncertainty Estimates and Handling Extreme Events

This paper is aimed at atmospheric scientists without formal training in statistical theory. Its goal is to, 1) provide a critical review of the rationale for trend analysis of the time series typically encountered in the field of atmospheric chemistry; 2) describe a range of trend-detection methods; and 3) demonstrate effective means of conveying the results to a general audience. Trend detections in atmospheric chemical composition data are often challenged by a variety of sources of uncertainty, which often behave differently to other environmental phenomena such as temperature, precipitation rate, or stream flow, and may require specific methods depending on the science questions to be addressed. Some sources of uncertainty can be explicitly included in the model specification, such as autocorrelation and seasonality, but some inherent uncertainties are difficult to quantify, such as data heterogeneity and measurement uncertainty due to the combined effect of short- and long-term natural variability, instrumental stability, and aggregation of data from sparse sampling frequency. Failure to account for these uncertainties might result in an inappropriate inference of the trends and their estimation errors. On the other hand, the variation in extreme events might be interesting for different scientific questions, for example, the frequency of extremely high surface ozone events and their relevance to human health. In this study we aim to, 1) review trend detection methods for addressing different levels of data complexity in different chemical species; 2) demonstrate that the incorporation of scientifically interpretable covariates can outperform pure numerical curve fitting techniques in terms of uncertainty reduction and improved predictability; 3) illustrate the study of trends based on extreme quantiles that can provide insight beyond standard mean or median based trend estimates; and 4) present an advanced method of quantifying regional trends based on the inter-site correlations of multi-site data. All demonstrations are based on time series of observed trace gases relevant to atmospheric chemistry, but the methods can be applied to other environmental data sets.

Trace gas↗

Qualitative Headspace GCMS Analysis of Lunar Regolith and Volatile Simulant Mixtures

Introduction: Future Artemis missions aim to return the volatile-bearing samples collected near lunar polar craters. We, as advanced curation scientists, are responsible for developing techniques and methodologies for preserving the integrity of returned samples and the science value those samples contain. The extent to which that preservation is possible, and the trade-offs preservation requires (e.g. monetary costs, sample volume limitations) all must be considered. Even less-than pristine volatile-bearing samples will be of tremendous value to the scientific community seeking to unravel the history of lunar surface volatiles and, more broadly, volatiles in the solar system. A sample collected on the lunar surface will experience at least five distinctive periods during which any changes here referred to as “alteration” will certainly occur at some scale: collection on the lunar surface; transportation back to Earth; long-term storage; curatorial processing; and allocation/distribution. The Planetary Exploration and Astromaterials Research Lab (PEARL) seeks to understand temperature and pressure effects on returned volatile samples by working with high-fidelity volatile-containing regolith simulants, setting the foundation for the future of cold curation. This abstract is focused on gas-surface interactions between LCROSS volatiles and readily available lunar regolith simulants. Experiments involved analyzing differences in headspace gas composition for various combinations of volatile and regolith simulants using gas chromatography/mass spectrometry (GC/MS). Experimental Procedure: The volatile simulants were chosen based on the molecules detected during the LCROSS mission.1 Stock solutions of condensed lunar volatile analytes were: methanol, 7 N ammonia in methanol, and 0.4% hydrogen sulfide in water. The regolith simulants used were primarily JSC-1A and NU-LHT-4M. Additional regolith simulant control studies were conducted with <150 μm sieved sand and KBr. A nested vial sample preparation approach separated the liquid stock solutions from the regolith, eliminating potential matrix effects between liquid and solid phases. Fifteen microliter aliquots of liquid volatile simulants were added to a 2 mL liquid GC vial and capped in atmosphere. An 18G needle punctured the 2 mL GC vial immediately before being transferred and sealed in a 20 mL GC vial containing 0-0.3 g of regolith simulant, see Figure 1. Separating the analytes ensures any changes observed in the total headspace gases is a result of gas-surface and/or gas-gas interactions. Equipment and Method: Initial GC/MS method development for the separation and identification of relevant headspace gases can be found in Amick, et al. 2023.2 The only hardware change is a different column: a TG-1701MS 30 m × 0.25 mm × 1.00 μm column. The vials were sampled at 10°C, room temperature (~25°C) and 50°C. Low temperature samples were kept in a chilled autosampler stage for at least 1 hour prior to sampling. High temperature samples were agitated at 50°C for 5 minutes immediately prior to injection onto the column. Headspace chromatograms were collected for each combination of temperature, regolith, and volatile simulant, including controls without one or both types of analytes, in triplicate. The chromatogram elution window for each analyte or significant atmospheric gas was identified using the peak mass spectrum cross-referenced with Figure 1.Picture of the nested vial set-up. a NIST MS library search. Each analyte peak was integrated after filtering the mass spectrum trace for the parent or most unique mass-to-charge ratio. For example, the mass-to-charge ratio used to identify, filter for, and integrate the carbon dioxide peak was centered around 44 m/z. Results: Figure 2 shows the integrated peak area for hydrogen sulfide in all combinations of regolith simulants, temperatures, and the addition of ammonia in methanol solution. Multiple repeat experiments with H2S and regolith simulants have confirmed hydrogen sulfide is removed from the headspace within 1 hour when exposed to JSC-1A, NU-LHT-4M and sand (not pictured). The consumption of H2S by lunar regolith simulants at different temperatures indicates surface chemistry will be an integral component in sample integrity and preservation. It is important to note that while the effect of surface chemistry on gaseous hydrogen sulfide is intriguing, further investigation into more chemically accurate regolith simulants is necessary and ongoing. The sulfur in hydrogen sulfide is in its most reduced state while off-the-shelf, terrestrially sourced JSC-1A and NU-LHT-4M are more oxidized than most lunar materials,3which likely leads to different oxidation-reduction reactions than would be expected in lunar regolith. Figure 3 shows the integrated peak area of carbon dioxide for each sample combination that contained ammonia in methanol solution. The addition of ammonia to the GC vials results in a consistent and reproducible decrease in carbon dioxide gas, even at 50°C. The effect became more pronounced when JSC-1A or NU-LHT-4M were present. This set of experiments demonstrated that the sample composition will affect the chemical and physical state of each component present. Future spectroscopic and microscopy experiments will be geared towards identifying the cause for the CO2(g) concentration decrease and the consumption of hydrogen sulfide. As cold and volatile curation scientists, this information provides necessary insight on how to appropriately handle and analyze volatile bearing returned samples, as well as predict the effect chemical composition has on the various sample phases we will analyze upon return to Earth. Unlike traditional curation of geologic materials, the molecules in a sample cannot be identified or processed using the naked eye or even an optical microscope. Volatile curation will require a combination of analytical techniques, including but not limited to highly sensitive gas and solid/condensed phase spectroscopy. This set of experiments has demonstrated the need for more detailed studies of volatile mixtures with mineralogically and geochemically analogous lunar regolith simulants to prepare for the curation of volatile-rich lunar samples from the south polar region of the Moon. References: [1] Colaprete, A., et al. (2010) Science, 330, (463-468). [2] Amick, C. L., et al.(2023) Houston, Texas, [3] Heiken, G. H., et al.(1991) (778-778)

Cecilia L Amick↗