Engineering Papers⌕ Search

SEARCH · Engineering Papers

Results for “Texas”

Search indexed NASA NTRS and DOE OSTI research on propulsion, heat transfer, battery materials and energy systems. Follow report and document links to the original sources.

Quote a phrase for an exact phrase match. Source license links do not imply unrestricted reuse.

At least 433 records · Page 24

Hydraulic Fractures in Core From Stimulated Reservoirs: Core Fracture Description of HFTS Slant Core, Midland Basin, West Texas

The geometry and extent of the hydraulic-fracture network produced during well stimulation are generally not well known. Indirect methods such as microseismic monitoring may provide information about the network, but they are not definitive. The Hydraulic Fracture Test Site (HFTS) project was designed to recover core from a stimulated volume, thus providing direct information about hydraulic fractures. Here we present methods and some results from a fracture description of the HFTS slant well cores. Methods: The 4-inch-diameter cores were contained within an aluminum tube and were examined prior to slabbing. We developed criteria for distinguishing between hydraulic, natural, drilling-induced, and core-handling fractures by examining the orientation and surface features of all fractures, making use of a CT scan of the core. Results: More than 700 fractures total were found in 600 ft of core, including hydraulic fractures, two sets of calcite-sealed natural fractures, and drilling-induced and core-handling fractures. Hydraulic fractures were found to be most abundant in the section of core closest to the stimulated wells. Significance: Benefits from an experiment of this type are: (1) Hydraulic fractures are observed directly, allowing fracture density and spatial distribution to be quantified. (2) Twist hackles on hydraulic-fracture surfaces may provide information about the direction of fracture propagation. (3) The degree to which natural, sealed fractures have been reactivated may be assessed. (4) Proppant distribution in the fractures can be examined. (5) Details of the observed hydraulic-fracture network can be used to verify, or provide input data for, models of hydraulic-fracture growth and proppant distribution. (6) Findings can provide ground truth for indirect diagnostic techniques such as microseismic monitoring. (7) Fractures in core and image log in the same well can be compared, and findings used to help calibrate other horizontal well image logs.

Gale, Julia↗

Surface Seismic Monitoring of Hydraulic Fracturing Test Site (HFTS) in the Midland Basin, Texas

Low-frequency seismic events of long duration were recorded by a surface array of 48, 3-component geophones during the fracture stimulation of two offset horizontal wells in the Middle Wolfcamp Formation (8000-8100 ft. below the geophone array) at the Hydraulic Fracturing Test Site (HFTS) in Reagan County, TX. Each recorded event was approximately 5-10 seconds long, with no clear first wave arrival; the seismic energy was largely visible on the vertical component suggesting that the events are dominated by P waves. A finite temporal moveout was observed across the seismic network in event arrival times indicating a causal relationship with the local source of deformation. The low-frequency seismic events observed in this study can be distinguished from the more commonly known microseismic events by their: 1) emergent waveform, 2) lack of clear P wave and S wave arrivals, 3) longer duration (few seconds), and 4) lower-frequency energy content (10-60 Hz). Previous researchers have observed similar low-frequency, long duration events in conjunction with the hydraulic fracturing of hydrocarbon reservoirs and have referred to them as long-period, long-duration (LPLD) events in the literature. LPLD events may be important to a comprehensive understanding of fracture stimulation because these events are thought to represent: 1) movement along pre-existing discontinuities such as bedding planes and fractures/faults, 2) deformation of ductile rocks with high clay content, and 3) the jerky tensile opening of hydraulic fractures. LPLD events resulting from slow shear-slip on faults and fractures of relatively larger dimension or rupture in the clay rich rock are collectively referred to as slow-slip seismicity, which was first observed in tectonic and volcanic settings, areas with high pore pressure like hydraulically fractured reservoirs. Because LPLDs are thought to represent deformation mechanisms not captured by microseismic analysis (which dominantly indicate shear failure of brittle rock), we believe that incorporating LPLD events into a new methodology for delimiting stimulated reservoir volume might improve predictions of well production.

Kumar, Abhash↗

Fracture Description of the HFTS-2 Slant Core, Delaware Basin, West Texas

Previous work in the Midland Basin Hydraulic Fracture Test Site project (HFTS1) has shown the value of core recovered from a stimulated volume in providing information on the geometry and extent of hydraulic fractures. This project (HFTS2) is in the Wolfcamp Formation of the Delaware Basin. A slant core through the stimulated volume was acquired above and below a stimulated well and the results of the fracture description are presented here. Here, nine, 3-inch-diameter whole cores from the slant well were examined for fractures prior to slabbing, together with a CT scan of the core. We used criteria developed during the HFTS1 project to identify hydraulic, natural, drilling-induced and core-handling fractures. Material collected from a few fracture faces was cleaned, sieved, and examined under a microscope to look for proppant. A total of 1261 fractures, including 500 hydraulic fractures, were described in 948 feet of core. Hydraulic fractures are not evenly distributed through the cores; they tend to occur in clusters. Many are remarkably planar, smooth, and featureless, while others have twist hackles, steps, plumose, and kinks. Natural, subvertical fractures, mostly less than 1 mm in width, sealed with blocky calcite, are oriented NE-SW (Set 1) and WNW-ESE (Set 2). Two Set 1 fractures have drusy cement on parted faces and were possibly open prior to drilling. A few subvertical sealed fractures with different orientations are also present. Bed-parallel natural fractures, most having fibrous cement (beef), and some showing top-to-north bed-parallel shear are present. Faults with normal/oblique movement were found in one part of the core. Drilling induced and core-handling breaks were identified in all cores, and were also noted to have reactivated some natural fractures. The results from this work will allow hydraulic fracture distribution relative to the stimulated well to be assessed. The number of fractures is generally greater than the number of perforations, but these can be compared for different stages and perforation clusters. Surface features provide information about the direction of hydraulic fracture propagation and about segmentation and bifurcation that might increase the number of fracture strands. Reactivation of natural fractures, including bedding-parallel fractures, occurs although the mechanism of parting is mostly unknown. The wider HFTS2 project will make use of this fracture description to improve hydraulic fracture modeling (geomechanics and engineering), to help explain pressure depletion and fiber optics observations (reservoir depletion and frac geometry), to help verify indirect fracture diagnostic techniques such as microseismic monitoring (geophysics), and to help calibrate horizontal well image logs.

58 GEOSCIENCES↗

Microhole VSP - CO2 EOR - Wickett, Texas

This data archive is three vertical seismic profile (VSP) data sets recorded in 2007 and 2008 using microhole technology to monitor a CO2 EOR flood in a Wickett, TX oil field (known as North Ward/Estes field). Five microhole wells with permanent vertical component geophone sensors were used for monitoring.

CO2↗

Core Analysis E-Reports Produced for the Southwest Regional Partnership on Carbon Sequestration for Wells 13-10A, 13-14, and 32-8 of the Farnsworth Unit, Texas

The submission is three electronic reports (e-reports) produced by Terra Tek, a former Schlumberger company, for and under the oversight of the Southwest Regional Partnership on Carbon Sequestration (SWP). The SWP designed and implemented a coring and core analysis program in conjunction with the previous field operator Chaparral Energy, L.L.C. The main SWP contacts who oversaw the coring and core analysis program, including geologic core descriptions and sample selection for testing by the Terra Tek, are listed below in the Authors section. The three reports are for Wells 13-10A, 13-14, and 32-8 of the Farnsworth Unit, TX, a site of the SWP's CO2 storage and enhanced oil recovery project. The e-reports include many data types that are not listed in full detail here, but may include: geomechanical, geochemical, and petrophysical measurements; white light and UV core photos; spectral gamma logs on the core; and Heterogeneous Rock Analysis logs. Fracture core review reports are included for Wells 13-14 and 32-8. The three e-reports each have many subfolders with the various types of data in spreadsheets, pdfs, image files, or other formats. The main e-reports for each well are listed by the well name. The sub-folder “E-Report” for each well has a Report.html file, which, when opened, will have hyperlinks to the various data sets and information. The files in the zipped folder will need to be extracted for the Report.html files to work properly. These authors thank Joseph Hall, a geologist formerly of Chaparral Energy, L.L.C., for assistance in designing the coring program, his geologic expertise of the Farnsworth Unit, and his assistance with characterizing the core. Christopher Gillespie, of Terra Tek at the time, managed the myriad geomechanical, geochemical, and petrophysical measurements provided by Terra Tek for this project. The core from which the samples were collected for this project are housed at the Subsurface Data and Core Libraries of the New Mexico Bureau of Geology and Mineral Resources, Socorro, New Mexico, USA. Funding for this project is provided by the U.S. Department of Energy's (DOE) National Energy Technology Laboratory (NETL) through the Southwest Regional Partnership on Carbon Sequestration (SWP) under Award No. DE-FC26-05NT42591. Sandia National Laboratories is a multimission laboratory managed and operated by National Technology & Engineering Solutions of Sandia, LLC, a wholly owned subsidiary of Honeywell International Inc., for the U.S. Department of Energy’s National Nuclear Security Administration under contract DE-NA0003525. These e-reports describe objective technical results and analysis. Any subjective views or opinions that might be expressed in the reports do not necessarily represent the views of the US Department of Energy or the United States Government.

Caprock↗

Solar Resource Measurements in El Paso, Texas (Equipment CRADA Only) (CRADA Final Report)

Site-specific, long-term, continuous, and high-resolution measurements of solar irradiance are important for developing renewable resource data. These data are used for several research and development activities consistent with the NREL mission: establish a national 30-year climatological database of measured solar irradiances; provide high quality ground-truth data for satellite remote sensing validation; support development of radiative transfer models for estimating solar irradiance from available meteorological observations; provide solar resource information needed for technology deployment and operations.

14 SOLAR ENERGY↗

Pecan Street Smart Grid Extension Service at the University of Texas

Through funding from the Department of Energy’s Electricity Delivery and Reliability Office, Pecan Street Inc., in partnership with Austin Energy and Oncor, developed and tested third- party data access platforms and services for Green Button offerings and for other home energy use data providers. As more utilities seek to offer Green Button-compliant data to their customers, the question continually arises of how this data can be used to help customers better manage their energy use.

24 POWER TRANSMISSION AND DISTRIBUTION↗

HVAC Design Strategy for a Hot-Humid Production Builder, Houston, Texas (Fact Sheet)

BSC worked directly with the David Weekley Homes - Houston division to redesign three floor plans in order to locate the HVAC system in conditioned space. The purpose of this project is to develop a cost effective design for moving the HVAC system into conditioned space. In addition, BSC conducted energy analysis to calculate the most economical strategy for increasing the energy performance of future production houses. This is in preparation for the upcoming code changes in 2015. The builder wishes to develop an upgrade package that will allow for a seamless transition to the new code mandate. The following research questions were addressed by this research project: 1. What is the most cost effective, best performing and most easily replicable method of locating ducts inside conditioned space for a hot-humid production home builder that constructs one and two story single family detached residences? 2. What is a cost effective and practical method of achieving 50% source energy savings vs. the 2006 International Energy Conservation Code for a hot-humid production builder? 3. How accurate are the pre-construction whole house cost estimates compared to confirmed post construction actual cost? BSC and the builder developed a duct design strategy that employs a system of dropped ceilings and attic coffers for moving the ductwork from the vented attic to conditioned space. The furnace has been moved to either a mechanical closet in the conditioned living space or a coffered space in the attic.

32 ENERGY CONSERVATION, CONSUMPTION, AND UTILIZATI↗

City of San Antonio, Texas Better Buildings Program

The San Antonio Better Buildings Program is a unified single-point-of-service energy efficiency delivery mechanism targeting residential, commercial, institutional, industrial and public buildings. This comprehensive and replicable energy efficiency program is designed to be an effective demand side management initiative to provide a seamless process for program participants to have turn-key access to expert analysis, support and incentives to improve the performance of their in-place energy using systems, while reducing electrical energy use and demand.

32 ENERGY CONSERVATION, CONSUMPTION, AND UTILIZATI↗

Solar Resource Measurements in Canyon, Texas - Equipment Only Loan: Cooperative Research and Development Final Report, CRADA Number CRD-07-233

Site-specific, long-term, continuous, and high-resolution measurements of solar irradiance are important for developing renewable resource data. These data are used for several research and development activities consistent with the NREL mission: establish a national 30-year climatological database of measured solar irradiances; provide high-quality ground-truth data for satellite remote sensing validation; support development of radiative transfer models for estimating solar irradiance from available meteorological observations; and provide solar resource information needed for technology deployment and operations. Data acquired under this agreement will be available to the public through NREL's Measurement & Instrumentation Data Center (MIDC) or the Renewable Resource Data Center (RReDC). The MIDC offers a variety of standard data display, access, and analysis tools designed to address the needs of a wide user audience (e.g., industry, academia, and government interests).

14 SOLAR ENERGY↗