Engineering Papers⌕ Search

SEARCH · Engineering Papers

Results for “Test methods”

Search indexed NASA NTRS and DOE OSTI research on propulsion, heat transfer, battery materials and energy systems. Follow report and document links to the original sources.

Quote a phrase for an exact phrase match. Source license links do not imply unrestricted reuse.

At least 433 records · Page 24

Dynamic Holography Method for Nondestructive Testing of Optical Homogeneity of Transparent Media

The potential of the dynamic holography method for testing the phase optical homogeneity of media transparent in visible light has been considered. This method is based on imaging samples in the scheme of two-wave mixing of the second-harmonic radiation of a Nd:YAG laser and image amplification in a photorefractive barium-strontium niobate crystal. Examples of identifying phase inhomogeneities at a level of 10{sup -5} cm{sup -1} and less in crystals of different compositions are presented.

75 CONDENSED MATTER PHYSICS, SUPERCONDUCTIVITY AND↗

Investigating the Dynamic Compaction Behavior of Brittle Powders

The compression of porous materials to full density is a complex physical and mechanical process. Modeling efforts to capture the compaction behavior of distended solids (e.g., porous materials or powders) have produced a variety of compaction models, each functionalized to address specific compaction mechanisms. Of the available models, those suited for high-strain-rate deformation associated with shock loading have generally been developed for ductile materials. Compaction models for brittle materials have only been developed for quasistatic loading conditions. No predictive models currently exist that successfully capture the physical processes and mechanics for shock compaction of brittle distended materials, such as sand and oxide powders. The primary hindrance in producing a dynamic compaction model for brittle distended materials is the lack of availability of high-fidelity, high-precision shock compaction data for validation. The proposed work is aimed at alleviating this issue by developing a high-precision testing method in combination with high-fidelity analysis methods to accurately and precisely determine the shocked state of an ideal test material, ceria powder, under uniaxial strain dynamic compaction. The measured shock compaction data from these brittle powder experiments is then used in initial computations to design a cylindrically converging shock compaction experiment within situ time-resolved shocked density measurements, employing proton radiography. The preliminary experimental and computational results obtained from these uniaxial strain dynamic compaction and cylindrically converging shock compaction experiments are presented. An experimental and computational path forwards to predictive model development is then proposed.

36 MATERIALS SCIENCE↗

Response Time Analysis and Test of Protection System Instrument Channels for APR1400 and OPR1000

Safety limits are required to maintain the integrity of physical barriers designed to prevent the uncontrolled release of radioactive materials in nuclear power plants. The safety analysis establishes two critical constraints that include an analytical limit in terms of a measured or calculated variable, and a specific time after the analytical limit is reached to begin protective action. Keeping with the nuclear regulations and industry standards, satisfying these two requirements will ensure that the safety limit will not be exceeded during the design basis event, either an anticipated operational occurrence or a postulated accident. Various studies on the setpoint determination methodology for the safety-related instrumentation have been actively performed to ensure that the requirement of the analytical limit is satisfied. In particular, the protection setpoint methodology for the advanced power reactor 1400 (APP1400) and the optimized power reactor 1000 (OPR1000) has been recently developed to cover both the design basis event and the beyond design basis event. The developed setpoint methodology has also been quantitatively validated using specific computer programs and setpoint calculations. However, the safety of nuclear power plants cannot be fully guaranteed by satisfying the requirement of the analytical limit. In spite of the response time verification requirements of nuclear regulations and industry standards, it is hard to find the studies on the systematically integrated methodology regarding the response time evaluation. In cases of APR1400 and OPR1000, the response time analysis for the plant protection system is partially included in the setpoint calculation and the response time test is separately performed via the specific plant procedure. The test technique has a drawback which is the difficulty to demonstrate completeness of timing test. The analysis technique has also a demerit of resulting in extreme times that not actually possible. Thus, the establishment of the systematic response time evaluation methodology is needed to justify the conformance to the response time requirement used in the safety analysis. This paper proposes the response time evaluation methodology for APR1400 and OPR1000 using the combined analysis and test technique to confirm that the plant protection system can meet the analytical response time assumed in the safety analysis. In addition, the results of the quantitative evaluation performed for APR1400 and OPR1000 are presented in this paper. The proposed response time analysis technique consists of defining the response time requirement, determining the critical signal path for the trip parameter, allocating individual response time to each component on the signal path, and analyzing the total response time for the trip parameter, and demonstrates that the total analyzed response time does not exceed the response time requirement. The proposed response time test technique is composed of defining the response time requirement, determining the critical signal path for the trip parameter, determining the test method for each component on the signal path, performing the response time test, and demonstrates that the total test result does not exceed the response time requirement. The total response time should be tested in a single test that covers from the sensor to the final actuation device on the instrument channel. When the total channel is not tested in a single test, separate tests on groups of components or single components including the total instrument channel shall be combined to verify the total channel response. For APR1400 and OPR1000, the ramp test technique is used for the pressure and differential pressure transmitters and the step function testing technique is applied to the signal processing equipment and final actuation device. As a result, it can be demonstrated that the response time requirement is satisfied by the combined analysis and test technique. Therefore, the proposed methodology in this paper plays a crucial role in guaranteeing the safety of the nuclear power plants systematically satisfying one of two critical requirements from the safety analysis. (authors)

21 SPECIFIC NUCLEAR REACTORS AND ASSOCIATED PLANTS↗

Design of dehumidification test of HTR-PM - 18461

Moisture in the primary loop is harmful for the normal operation of the Modular High Temperature Gas-cooled Reactor (MHTGR). A dehumidification test to remove the moisture in the primary loop of the High Temperature Gas-cooled Reactor Pebble-bed Module (HTR-PM) reactor was proposed. This test consisted of two stages, stage A and stage B. The test process of stage A was divided into six steps including vacuuming, inflating, heating, dehumidifying, cooling and venting, while the test process of stage B only included the first five steps of stage A. Nitrogen and helium were respectively used as the dehumidification gas to carry away the moisture in the graphite in stage A and stage B, which were circulated and heated by the helium blower. What s more, preliminary calculations to heating and dehumidifying were implemented. Variations of water content of the graphite in the dehumidification process were obtained, and the times spent for different dehumidification targets were also worked out. It needs 19.5 days to remove 80% of the moisture in the graphite in stage A when the dehumidification temperature is 150 deg. C, and 14.3 days are needed to make water content in the graphite decrease from 20% to 5% in stage B. The results show that the test method proposed is feasible and effective, and offer references to the design, test and operation of the HTR-PM. (authors)

21 SPECIFIC NUCLEAR REACTORS AND ASSOCIATED PLANTS↗

Promoting the regulatory acceptance of combined ion and neutron irradiation for material degradation in nuclear reactors

The Advanced Materials and Manufacturing Technologies (AMMT) program within the Department of Energy (DOE) Office of Nuclear Energy has developed its current recommendation for promoting the use of combined ion irradiation and neutron irradiation for the accelerated qualification of materials to be deployed in nuclear reactors. This plan is intended to provide a collaborative path forward that can be adopted by academia, national laboratories, and industry, and has been developed with input from the regulatory research arm of the U.S. Nuclear Regulatory Commission (NRC). To deploy new materials or materials manufactured with new technologies, such as additive manufacturing, materials must be evaluated for reactor-induced degradation from the combination of harsh temperatures, corrosive environments, and radiation fields. However, rapid deployment of materials necessitates accelerated testing methods rather than relying on years of neutron irradiation in a material test reactor. Ion irradiation has demonstrated success in reproducing material microstructure and select property evolution resulting from neutron irradiation with three to four orders of magnitude reduction in time and cost, making it an ideal candidate for accelerated irradiation testing. This presentation provides context governing both the scientific and regulatory aspects of the proposed goal. The discussion is aimed at a broad audience including researchers from industry, national laboratories, and academia. The recommended path forward is presented as a conceptual framework of specific steps. In brief, the strategy entails developing an integrated ion and neutron irradiation test plan for the material property of interest based on the fundamental tenet of the linkage of microstructure and properties in materials. Physics-based modeling interprets ion irradiation data and predicts neutron irradiation microstructure and properties with uncertainty bounds. The first round of testing is sufficient for an initial licensing application using a risk-informed approach, while a minimum required neutron irradiation test plan reduces cost and time requirements. A surveillance program with witness specimens in-reactor provides additional data over time to improve model predictions to higher damage levels and further reduce uncertainty bounds, which can be used for license extensions or longer lifetimes in new license applications.

11 NUCLEAR FUEL CYCLE AND FUEL MATERIALS↗

Wear of Spheroidal Graphite Cast Irons for Tractor Drive Train Components

The study was prompted by a desire to improve the wear resistance of power transmission components in rear axle drives on commercial farm tractors. Reciprocating wear tests were conducted under lubricated and non-lubricated conditions on three spheroidal cast irons which varied in strength and hardness (designated GGG450, GGG600, and GGG700). Hemispherically-tipped steel pins (designed 42CrMoS4/ 41CrS4) were used as the sliders. Except for the test duration, test procedures were similar to those described in ASTM Standard Test Method G133 for linearly-reciprocating sliding. Among the three cast irons tested, the harder and stronger the alloy, the lower was its wear rate. Wear factors were approximately four orders of magnitude lower for experiments lubricated in fresh, fully-formulated lubricating oil. There was a linear relationship between Brinell hardness of the alloys and the negative logarithm of the wear factors that were expressed in (mm3/N-m). Wear of lubricated test pins was not measurable due to the presence of deposits; however under non-lubricated sliding, the ratio of the wear of the flat specimen to that of the pin decreased as the hardness of the flat specimens approached that of the pin specimen.

24 POWER TRANSMISSION AND DISTRIBUTION↗

Incidental Testicular Irradiation From Prostate IMRT: It All Adds Up

Purpose: To identify the technical aspects of image-guided intensity-modulated radiation therapy (IMRT) for localized prostate cancer that could result in a clinically meaningful incidental dose to the testes. Methods and Materials: We examined three sources that contribute incidental dose to the testes, namely, from internal photon scattering from IMRT small field and large pelvic nodal fields with 6 or 15 MV, from neutrons when >10-MV photons are used, and from daily image-guided fiducial-based portal imaging. Using clinical data from 10 patients who received IMRT for prostate cancer, and thermo-luminescent dosimeter measurements in phantom, we estimated the dose to the testes from each of these sources. Results: A mean testicular dose of 172 and 220 cGy results from internal photon scatter for pelvic nodal fields and 68 and 93 cGy for prostate-only fields, for 6- and 15-MV energies, respectively. For 15-MV photon energies, the mean testicular dose from neutrons is 60 cGy for pelvic fields and 31 cGy for prostate-only fields. From daily portal MV image guidance, the testes-in-field mean dose is 350 cGy, whereas the testes-out-of-field scatter dose is 16 cGy. Dosimetric comparisons between IMRT using 6-MV and 15-MV photon energies are not significantly different. Worst-case scenarios can potentially deliver cumulative incidental mean testicular doses of 630 cGy, whereas best-case scenarios can deliver only 84 cGy. Conclusions: Incidental dose to the testes from prostate IMRT can be minimized by opting to restrict the use of elective pelvic nodal fields, by choosing photon energies <10 MV, and by using the smallest port sizes necessary for daily image guidance.

62 RADIOLOGY AND NUCLEAR MEDICINE↗

Status of Initial Assessment of Physical and Mechanical Properties of Graphite Grades for NGNP Appkications

Current candidate graphite grades for the core structures of NGNP include grades NBG-17, NBG-18, PCEA and IG-430. Both NBG-17 and NBG-18 are manufactured using pitch coke, and are vibrationally molded. These medium grain products are produced by SGL Carbon SAS (France). Tayo Tanso (Japan) produces IG-430 which is a petroleum coke, isostatically molded, nuclear grade graphite. And PCEA is a medium grain, extruded graphite produced by UCAR Carbon Co. (USA) from petroleum coke. An experimental program has been initiated to develop physical and mechanical properties data for these current candidate graphites. The results will be judged against the requirements for nuclear grade graphites set forth in ASTM standard D 7219-05 "Standard Specification for Isotropic and Near-isotropic Nuclear Graphites". Physical properties data including thermal conductivity and coefficient of thermal expansion, and mechanical properties data including tensile, compressive and flexural strengths will be obtained using the established test methods covered in D-7219 and ASTM C 781-02 "Standard Practice for Testing Graphite and Boronated Graphite Components for High-Temperature Gas-Cooled Nuclear Reactors". Various factors known to effect the properties of graphites will be investigated. These include specimen size, spatial location within a graphite billet, specimen orientation (ag and wg) within a billet, and billet-to-billet variations. The current status of the materials characterization program is reported herein. To date billets of the four graphite grades have been procured, and detailed cut up plans for obtaining the various specimens have been prepared. Particular attention has been given to the traceability of each specimen to its spatial location and orientation within a billet.

01 COAL, LIGNITE, AND PEAT↗

Extended Bandwidth Spread Spectrum Time Domain Reflectometry Cable Test for Thermal Aging, Low Resistance Fault, and Water Detection

In 2022, researchers at Pacific Northwest National Laboratory (PNNL) used the Accelerated and Real-Time Environmental Nodal Assessment (ARENA) cable and motor test bed to characterize spread spectrum time domain reflectometry (SSTDR) and compare the responses of an SSTDR instrument to those of a frequency domain reflectometry (FDR) instrument. Results showed both techniques could detect and locate cable anomalies such as phase-to-phase low resistance and shorts, thermal insulation damage, mechanical insulation damage, and the presence or absence of water in some conditions. The SSTDR tests used a commercial instrument provided by LiveWire Innovations Inc. This commercial instrument performed tests at 6, 12, 24, and 48 MHz bandwidth. The results of these tests were compared to FDR tests where bandwidths could be extended up to 1.3 GHz, although the best responses for cable tests were from 100 to 500 MHz. Lower bandwidth signals can propagate better along the cable while higher bandwidths have higher resolution for impedance change reflections allowing more precise indication of location and separation of anomalies. The 2022 research found that FDR responses were clearer than SSTDR and speculated that a higher bandwidth SSTDR could more successfully detect and locate cable anomalies. One advantage of the SSTDR system investigated was that it was designed for energized online use up to 1,000 volts, which may be a significant advantage for nuclear power plant use. The LiveWire SSTDR instrument is an established product in the rail and aircraft industry and updating the SSTDR hardware parameters is difficult to justify without more conclusive testing. Therefore, a software adjustable laboratory SSTDR instrument was developed by PNNL and was used to test extended bandwidth SSTDR cable tests. Within the ARENA test bed, 42 cable conditions were tested with the PNNL SSTDR, FDR, and the LiveWire SSTDR—each operating at four different bandwidths. Observations and conclusions regarding the relative performance of the three instruments over different bandwidths are note below. Responses of the PNNL SSTDR (at 50 MHz) and the LiveWire SSTDR (at 48 MHz) were similar. The PNNL SSTDR higher frequency bandwidths behaved as expected showing sharper peaks and higher noise. This validated the PNNL SSTDR as a reasonable implementation of the SSTDR technology. Lower bandwidth SSTDR responses (particularly 6 and 12 MHz) may have increased value for use within longer cables but were not particularly effective at identifying anomalous cable behavior in the 100 ft cables tested here. The higher bandwidths of the PNNL SSTDR (50, 100, 200, and 400 MHz) did not provide substantially clearer cable reflectometry responses, but having the higher frequency responses available did add to the cable test evaluation. Strong responses to shorts and low impedance faults between phases were particularly evident in the higher bandwidth PNNL SSTDR and the FDR data. Measurements were repeatable, with similar responses obtained from a thermally aged cable for tests taken a month apart. Signal noise was affected in the unshielded cable by the local in-tray cable arrangement including proximity to metal edges and rungs of the cable tray. Foam isolation of the cable from the tray metal reduced in both FDR and SSTDR responses. Cable condition monitoring in nuclear power plants will likely benefit from both more informative off-line testing methods and from the development of on-line methods for continuous monitoring of cables in use. The LWRS-funded ARENA test bed was a valuable resource for this development and direct comparison of nuclear electrical cable condition monitoring technologies. Test results are targeted to guide industry advancement of testing and monitoring tools for cable aging management.

21 SPECIFIC NUCLEAR REACTORS AND ASSOCIATED PLANTS↗

Personnel Qualification and Certification Program in Pressure Decay Leak Testing on the RT-100 Type (B) Cask - 17229

The requirements for qualifications and certification of leak test personnel on Type (B) shipping casks have been more clearly defined with the recent release of ANSI N14.5-2014, Leak Tests on Radioactive Packages for Shipment. The latest version creates a standardized approach for qualifying and certifying personnel to conduct pre-shipment leakage tests on Type (B) packages. The U.S Nuclear Regulatory Commission (NRC) is currently updating the Regulatory Guide R.G 7.4, Leakage Tests on Packages for shipment of Radioactive Material, to endorse ANSI N14.5-2014. According to ANSI N14.5-2014, leakage testing shall be performed in accordance with written procedures by qualified and certified personnel in accordance with the requirements of ASNT SNT-TC-1A-2006, Recommended Practice for Personnel Qualification and Certification in Nondestructive Testing. This is a significant modification to the old standard, ANSI N14.5-1997, which simply states that pressure leak testing shall be conducted by trained and certified personnel without reference to any specific certification standards or regulations. SNT-TC-1A published by the American Society for Nondestructive Testing (ASNT) has several advantages to employers; namely, it allows for a Limited NDT Level II certification program. Limited certifications are especially valuable for personnel who possess limited experience and wish to become a certified Limited NDT Level II in a specific technique on a specific cask using a specific procedure and equipment. Robatel Technologies recently developed a comprehensive qualification and training program based on the recommendations of SNT-TC-1A for Exelon Corporation to certify their employees to a Limited NDT Level II in Pressure Decay Leak Testing on the RT-100 Cask. The project scope included the development of a training and qualification program (Written practice), writing a pressure decay leak test procedure, the design of a pressure decay leak test manifold, and the delivery of classroom training. The written practice outlines the requirements to ensure that personnel participating in the program have the necessary qualification, experience, and training to become certified in the leak test method. The program will give Exelon the liberty to conduct their own leak testing on the RT- 100 without the need to rely on outside resources for leak testing. When fully implemented, the program is expected to improve productivity and eliminate schedule delays, along with substantial economic benefits. Following the appropriate standards and industry best practices, the project was successfully completed and scheduled to be fully implemented by Exelon's Nuclear Stations by the end of 2016. (authors)

07 ISOTOPE AND RADIATION SOURCES↗

Conservative Estimation of Tail Probabilities from Limited Sample Data

Several sparse-sample uncertainty quantification (UQ) methods are compared for conservative but not overly conservative estimation of small tail probabilities involving responses that lay beyond specified thresholds in the tails of probability distributions. Sixteen very differently shaped distributions (or probability density functions, PDFs) and tail probability magnitudes ranging from 10 -5 to 10 -1 are considered in order for the study to be relevant to a wide range of risk analysis and quantification of margins and uncertainty (QMU) problems. The emphasis of the study is on limited data regimes ranging from N = 2 to 20 samples, reflective of most experimental and some expensive computational situations. Relatively simple sparse-sample UQ methods tested for this regime involve statistical tolerance interval "Equivalent Normal and related "Ensemble of Normals" and "Superdistribution (SD) approaches. (The independently derived SD is effectively equivalent to the Bayesian posterior predictive distribution given the assumptions of the derivation.) The performance of the methods was generally improved for N ≥ 5 samples with a generalized Jackknife resampling technique, which determines a tail probability estimate by averaging estimates from smaller sub-samples. Several quantitative metrics for method conservatism and accuracy of tail probability estimation are used to assess and rank the methods' performance over many random trials for each test PDF and probability magnitude. A variant of Bootstrap resampling was also tried, but did not significantly improve tail probability estimates in most cases. Detailed results are presented from over 100-million tests over the above factors that provide useful granular information on which methods or combination of methods perform best in various areas of the factor space.

97 MATHEMATICS AND COMPUTING↗

Gate frequency sweep: An effective method to evaluate the dynamic performance of AlGaN/GaN power heterojunction field effect transistors

With this paper we propose a test method for evaluating the dynamic performance of GaN-based transistors, namely, gate-frequency sweep measurements: the effectiveness of the method is verified by characterizing the dynamic performance of Gate Injection Transistors. We demonstrate that this method can provide an effective description of the impact of traps on the transient performance of Heterojunction Field Effect Transistors, and information on the properties (activation energy and cross section) of the related defects. Moreover, we discuss the relation between the results obtained by gate-frequency sweep measurements and those collected by conventional drain current transients and double pulse characterization.

75 CONDENSED MATTER PHYSICS, SUPERCONDUCTIVITY AND↗

An alternative calibration method for counting P-32 reactor monitors

Radioactivation of sulfur is a common technique used to measure fast neutron fluences in test and research reactors. Elemental sulfur can be pressed into pellets and used as monitors. The {sup 32}S(n, p) {sup 32}P reaction has a practical threshold of about 3 MeV and its cross section and associated uncertainties are well characterized [1]. The product {sup 32P} emits a beta particle with a maximum energy of 1710 keV [2]. This energetic beta particle allows pellets to be counted intact. ASTM Standard Test Method for Measuring Reaction Rates and Fast-Neutron Fluences by Radioactivation of Sulfur-32 (E265) [3] details a method of calibration for counting systems and subsequent analysis of results. This method requires irradiation of sulfur monitors in a fast-neutron field whose spectrum and intensity are well known. The resultant decay-corrected count rate is then correlated to the known fast neutron fluence. The Radiation Metrology Laboratory (RML) at Sandia has traditionally performed calibration irradiations of sulfur pellets using the {sup 252}Cf spontaneous fission neutron source at the National Inst. of Standards and Technology (NIST) [4] as a transfer standard. However, decay has reduced the intensity of NIST's source; thus lowering the practical upper limits of available fluence. As of May 2010, neutron emission rates have decayed to approximately 3 e8 n/s. In practice, this degradation of capabilities precludes calibrations at the highest fluence levels produced at test reactors and limits the useful range of count rates that can be measured. Furthermore, the reduced availability of replacement {sup 252}Cf threatens the long-term viability of the NIST {sup 252}Cf facility for sulfur pellet calibrations. In lieu of correlating count rate to neutron fluence in a reference field the total quantity of {sup 32}P produced in a pellet can be determined by absolute counting methods. This offers an attractive alternative to extended {sup 252}Cf exposures because it can be performed regardless of the characterization of the exposure environment. Count rates produced by sulfur pellets are correlated to the measured quantity of separated {sup 32}P. A posteriori spectral and cross section determination can be used to correlate the quantity of phosphorus back to a neutron fluence in a reference field. This paper outlines a method for the setup, calibration, and use of the detector systems, {sup 32}P sample preparation, and analysis of the beta spectrum. An uncertainty analysis and comparison to ASTM E265 is also included. (authors)

07 ISOTOPE AND RADIATION SOURCES↗

Novel scanning electron microscope bulge test technique integrated with loading function

Membranes and film-on-substrate structures are critical elements for some devices in electronics industry and for Micro Electro Mechanical Systems devices. These structures are normally at the scale of micrometer or even nanometer. Thus, the measurement for the mechanical property of these membranes poses a challenge over the conventional measurements at macro-scales. In this study, a novel bulge test method is presented for the evaluation of mechanical property of micro thin membranes. Three aspects are discussed in the study: (a) A novel bulge test with a Scanning Electron Microscope system realizing the function of loading and measuring simultaneously; (b) a simplified Digital Image Correlation method for a height measurement; and (c) an imaging distortion correction by the introduction of a scanning Moiré method. Combined with the above techniques, biaxial modulus as well as Young's modulus of the polyimide film can be determined. Besides, a standard tensile test is conducted as an auxiliary experiment to validate the feasibility of the proposed method.

46 INSTRUMENTATION RELATED TO NUCLEAR SCIENCE AND ↗

Nondestructive Examination Guidance for Dry Storage Casks

In this report, an assessment of NDE methods is performed for components of NUHOMS 80 and 102 dry storage system components in an effort to assist NRC staff with review of license renewal applications. The report considers concrete components associated with the horizontal storage modules (HSMs) as well as metal components in the HSMs. In addition, the report considers the dry shielded canister (DSC). Scope is limited to NDE methods that are considered most likely to be proposed by licensees. The document, ACI 349.3R, Evaluation of Existing Nuclear Safety-Related Concrete Structures, is used as the basis for the majority of the NDE methods summarized for inspecting HSM concrete components. Two other documents, ACI 228.2R, Nondestructive Test Methods for Evaluation of Concrete in Structures, and ORNL/TM-2007/191, Inspection of Nuclear Power Plant Structure--Overview of Methods and Related Application, supplement the list with additional technologies that are considered applicable. For the canister, the ASME B&PV Code is used as the basis for NDE methods considered, along with currently funded efforts through industry (Electric Power Research Institute [EPRI]) and the U.S. Department of Energy (DOE) to develop inspection technologies for canisters. The report provides a description of HSM and DSC components with a focus on those aspects of design considered relevant to inspection. This is followed by a brief description of other concrete structural components such as bridge decks, dams, and reactor containment structures in an effort to facilitate comparison between these structures and HSM concrete components and infer which NDE methods may work best for certain HSM concrete components based on experience with these other structures. Brief overviews of the NDE methods are provided with a focus on issues and influencing factors that may impact implementation or performance. An analysis is performed to determine which NDE methods are most applicable to specific components.

11 NUCLEAR FUEL CYCLE AND FUEL MATERIALS↗

High-Temperature Tensile and Creep Test Results on Thin Wall Tube Specimens of ODS Alloys 14YWT and OFRAC

High-temperature tensile and strain rate jump (SRJ) creep tests were conducted on axial specimens fabricated from thin wall tubes of the oxide dispersion strengthened (ODS) alloys 14YWT and OFRAC. The dimensions of the 14YWT thin wall tube was 10.7 mm OD, 0.5 mm WT and 0.92 m and of the OFRAC thin wall tube was 8.5 mm OD + 0.5 mm WT and 1.78 m in length. The axial specimens fabricated from the thin wall tubes were based on a dual-gauge design with gauge dimensions of 4 mm long and 2 mm wide. The tensile tests were conducted in air at 800ºC, 900ºC and 1,000ºC and the SRJ creep tests were conducted in air at 800ºC. Two axial specimens were used in each tensile and SRJ creep tests. The results of the tensile tests showed much lower yield stress (YS) compared to ultimate tensile strength (UTS) indicative of large work hardening properties. The results showed the UTS of OFRAC was higher than that of 14YWT by ~35 MPa at 800ºC. At 900ºC, the UTS of OFRAC and 14YWT was similar at 900ºC and at 1000ºC, the UTS of 14YWT was higher than that of OFRAC by ~10 MPa. The ductility properties of OFRAC were greater than that of 14YWT with higher values of uniform elongation (UE) and total elongation (TE) at all tensile test temperatures. The creep properties of 14YWT and OFRAC were evaluated by the strain rate jump test method at 800ºC. The stress exponent (n) for creep was obtained from the SRJ test data by plotting the values of the log strain rate against the log stress, which is measured from the stress-strain curve generated during the SRJ test. The results showed the highest stress exponents of n = 19.8 and n = 35.0 were measured from the two SRJ tests on 14YWT. The stress exponent measured from one successful SRJ test on OFRAC was n = 13.3, which was lower than that of 14YWT. Nevertheless, these high values of stress exponent are consistent with ODS ferritic alloys such as 14YWT and OFRAC since they indicate dislocation-particle interactions are the dominant creep mechanism for specific ranges of temperature and stress. The results obtained from the tensile and SRJ creep tests conducted on axial specimens in this study indicate that 14YWT and OFRAC retain high strengths at temperatures up to 1,000ºC and good creep performance at 800ºC.

36 MATERIALS SCIENCE↗

Evaluation of a laboratory-developed multiplex real-time PCR assay for diagnosis of syphilis, herpes and chancroid genital ulcers in four public health laboratories in the USA

Objective To evaluate the field performance of a multiplex PCR (M-PCR) assay for detection of herpes simplex virus (HSV)-1 and HSV-2, Treponema pallidum ( T. pallidum ) and Haemophilus ducreyi ( H. ducreyi ) in genital ulcer disease (GUD) specimens. Methods GUD M-PCR was performed on 186 remnant specimens, previously collected for HSV testing, by four public health laboratories (PHLs) and the Laboratory Reference and Research Branch (LRRB) at the Centers for Disease Control and Prevention. The results from the PHLs were compared with those of LRRB, which served as the reference testing method, and percentage agreement was calculated. Results HSV was detected in 31 of 52 (59.6%), 20 of 40 (50%), 43 of 44 (97.7%) and 19 of 50 (38.0%) specimens from PHL1, PHL2, PHL3 and PHL4, respectively. There were seven discrepant results for HSV, and the overall percent agreement between the PHLs and the LRRB was 94%–100%, with a kappa value of 0.922, which demonstrates high agreement. T. pallidum was identified in 7 of 51 (13.7%) specimens from PHL1 with 94.1% agreement and in 2 of 40 (5.0%) specimens from PHL2 with 100% agreement. The LRRB identified three additional T. pallidum -positive specimens from PHL1. The kappa value (0.849) for T. pallidum testing suggests good agreement. Consistent with the LRRB results, no T. pallidum was detected in specimens from PHL3 and PHL4, and H. ducreyi was not detected at any of the study sites. Conclusions The GUD M-PCR assay performed well in four independent PHLs and 12 suspected syphilis cases were identified in this study. The M-PCR assay could provide improved diagnostic options for GUD infections in state and local PHLs.

Infectious Diseases↗

Simulation supported POD: Methodology and HFET validation case

Structure reliability guaranty requires prior evaluation of non destructive testing methods. The concept of Probability of Detection (POD) is generally used to quantitatively assess performances and reliability of testing operations. Such probabilistic approaches take into account the uncertainties that appear during inspections and that are responsible for the output variability. POD curve determination is based on costly and time consuming experimental campaigns. Increasing demand of NDT configurations requiring POD evaluation makes cost reduction of POD campaigns a major issue. A new trend is to apply simulation in the context of probabilistic approaches in order to replace some of the experimental data required to determine the POD with simulation results. This paper presents results of simulation based POD curves of a high frequency eddy current inspection procedure obtained with the new POD module of CIVA. The methodology used for describing uncertainties on the input simulation parameters is described and comparisons with experimental results are presented and discussed.

21 SPECIFIC NUCLEAR REACTORS AND ASSOCIATED PLANTS↗