Engineering Papers⌕ Search

SEARCH · Engineering Papers

Results for “Tank testing”

Search indexed NASA NTRS and DOE OSTI research on propulsion, heat transfer, battery materials and energy systems. Follow report and document links to the original sources.

Quote a phrase for an exact phrase match. Source license links do not imply unrestricted reuse.

At least 433 records · Page 24

Critical Experiments Targeting the Epithermal/Intermediate Cross Sections of Tantalum

Sandia National Laboratories (SNL) and Oak Ridge National Laboratory (ORNL) have collaborated to develop a capability to test the epithermal/intermediate cross sections of materials at the SNL critical experiments facility using the Seven Percent Critical Experiment (7uPCX) fuel. The Sandia Critical Experiments Program provides a specialized facility for performing water moderated and reflected critical experiments with UO 2 fuel rod arrays. The facility offers the ability to modify the core configuration and reactor tank to evaluate various reactor cores for pitch, moderator characteristics, and other criteria. A history of safe operations and flexibility in reactor core configuration has resulted in the completion of nine sets of critical benchmark experiments that have been documented in the International Criticality Safety Benchmark Evaluation Project (ICSBEP) Handbook. The experiment described here is expected to be evaluated for inclusion in the 2024 edition of the ICSBEP Handbook.

11 NUCLEAR FUEL CYCLE AND FUEL MATERIALS↗

Numerical predictions of cryogenic hydrogen vertical jets

Here, a comparison of Computational Fluid Dynamics (CFD) predictions with measurements is presented for cryo-compressed hydrogen vertical jets. The stagnation conditions of the experiments are characteristic of unintended leaks from pipe systems that connect cryogenic hydrogen storage tanks and could be encountered at a fuel cell refueling station. Jets with pressure up to 5 bar and temperatures just above the saturation liquid temperature were examined. Comparisons are made to the centerline mass fraction and temperature decay rates, the radial profiles of mass fraction and the contours of volume fraction. Two notional nozzle approaches are tested to model the under-expanded jet that was formed in the tests with pressures above 2 bar. In both approaches the mass and momentum balance from the throat to the notional nozzle are solved, while the temperature at the notional nozzle was assumed equal to the nozzle temperature in the first approach and was calculated by an energy balance in the second approach. The two approaches gave identical results. Satisfactory agreement with the measurements was found in terms of centerline mass fraction and temperature. However, for test with 3 and 4 bar release the concentration was overpredicted. Furthermore, a wider radial spread was observed in the predictions possibly revealing higher degree of diffusion using the k-ε turbulence model. An integral model for cryogenic jets was also developed and provided good results. Finally, a test simulation was performed with an ambient temperature jet and compared to the cold jet showing that warm jets decay faster than cold jets.

08 HYDROGEN↗

Marine energy supported multi-energy system planning and operation optimization for sustainable coastal community

The growing need for sustainable energy solutions in coastal areas necessitates the development of integrated systems that leverage abundant marine resources. In this study, a standalone Marine Energy Supported Multi-Energy System (MRE-MES) is designed for sustainable coastal community development, utilizing renewable marine resources, including offshore wind, wave, and solar energy, to address the energy needs of electricity, heat, freshwater, and hydrogen. The proposed MRE-MES incorporates a co-optimization model that simultaneously balances capacity planning and operational efficiency to minimize costs and environmental impacts. The system is tested under different renewable energy penetration levels and demand uncertainties, using a two-stage stochastic programming to account for variability in renewable resources and consumption needs. The experimental results indicate that in the optimal system capacity configuration, the percentage of total renewable energy generation is around 80 %, with or without capacity limitation constraints on PV, water tank, and hydrogen storage. Compared to the worst-case scenario in Monte Carlo experiments, two-stage stochastic optimization results in a more robust decision that effectively mitigates the risks posed by future uncertain demand conditions. In conclusion, the findings highlight the viability of marine energy for providing a resilient, comprehensive energy solution to coastal communities.

Capacity planning↗

Warrick Conductivity Level Controllers Series 3H

This is my internship poster. In the poster I talk about the level controllers that I wired together and installed to support electrolysis testing systems in efforts to make the systems more efficient and run based on the communication between devices to ensure a closed loop system that can run on its own in a safe and controlled manner. I included pictures of some of the wiring as well as the level sensor devices and relays. I also included pictures of the tanks that will be filled at different heights with deionized water based on where the level sensors are.

08 HYDROGEN↗

Optical characterization of the on-target OMEGA focal spot at high energy using the full-beam in-tank diagnostic

The full-beam in-tank (FBIT) diagnostic has been deployed to directly measure the target-plane beam fluence profile, when operated at high energy, of the OMEGA Laser System at the University of Rochester’s Laboratory for Laser Energetics. This article presents the results of early measurements taken with this diagnostic and discusses an improvement that has overcome performance limitations discovered during the initial testing. The diagnostic gives new insight into the ability of the OMEGA Laser System to provide uniform fluence profiles that are consistent across all 60 beams in the laser. Overall, the ultimate goal of the FBIT diagnostic is to allow accurate assessment of the fluence uniformity on a spherical target in 60-beam implosion experiments

47 OTHER INSTRUMENTATION↗

Spent Crystalline Silicotitanate Storage Study—Post AP-105DF Processing

A Tank-Side Cesium Removal (TSCR) system is under development by Washington River Protection Solutions to support initial production of immobilized low-activity waste (LAW) by feeding Hanford tank supernate from tank farms to the Hanford Waste Treatment and Immobilization Plant (WTP) LAW Facility. Tank waste supernate is filtered to remove suspended solids and then Cs is removed by processing it through crystalline silicotitanate (CST) ion exchange media manufactured by Honeywell UOP, LLC. The Cs-loaded CST columns will be stored indefinitely, with a goal of eventual CST removal and treatment. Thus, the spent CST needs to be recoverable after undetermined storage time. Previous testing with AP-105 simulant showed that rinsing the CST bed with 3 bed volumes (1.4 apparatus volumes [AVs]) of 0.1 M NaOH resulted in a dried bed that maintained flow characteristics indicative of ease of recovery. This study explored the intermediate conditions (between feed dried in place and the 1.4 AVs of 0.1 M NaOH rinse) to evaluate CST bed properties.

12 MANAGEMENT OF RADIOACTIVE AND NON-RADIOACTIVE W↗

Continued Investigations of Respirable Release Fractions for Stress Corrosion Crack-Like Geometries

The formation of a stress corrosion crack (SCC) in the canister wall of a dry cask storage system (DCSS) has been identified as a potential issue for the long-term storage of spent nuclear fuel. The presence of an SCC in a storage system could represent a through-wall flow path from the canister interior to the environment. Modern, vertical DCSSs are of particular interest due to the commercial practice of using relatively high backfill pressures (up to approximately 800 kPa) in the canister to enhance internal natural convection. This pressure differential offers a comparatively high driving potential for blowdown of any particulates that might be present in the canister. In this study, the rates of gas flow and aerosol transmission of a spent fuel surrogate through an engineered microchannel with dimensions representative of an SCC were evaluated experimentally using coupled mass flow and aerosol analyzers. The microchannel was formed by mating two gage blocks with a linearly tapering slot orifice nominally 13 μm (0.005 in.) tall on the upstream side and 25 μm (0.0010 in.) tall on the downstream side. The orifice is 12.7 mm (0.500 in.) wide by 8.89 mm (0.350 in.) long (flow length). Surrogate aerosols of cerium oxide, CeO 2 , were seeded and mixed with either helium or air inside a pressurized tank. The aerosol characteristics were measured immediately upstream and downstream of the simulated SCC at elevated and ambient pressures, respectively. These data sets are intended to demonstrate a new capability to characterize SCCs under well-controlled boundary conditions. Modeling efforts were also initiated that evaluate the depletion of aerosols in a commercial dry storage canister. These preliminary modeling and ongoing testing efforts are focused on understanding the evolution in both size and quantity of a hypothetical release of aerosolized spent fuel particles from failed fuel to the canister interior and ultimately through an SCC.

11 NUCLEAR FUEL CYCLE AND FUEL MATERIALS↗

FY2020 Rotating Bed Reactor for Iodine Removal from WTP Melter Effluent to Support DFLAW Start-Up

In Performance Assessment (PA) of the Hanford Integrated Disposal Facility (IDF), 129 I is a significant contributor to the risk. The 2017 IDF PA accounted for 0.22% of the total 129 I inventory in Hanford tank waste as residing in the solidified liquid waste from the Effluent Treatment Facility (ETF). However, recent estimates suggest that higher percentages of the iodine processed at the Hanford Waste Treatment and Immobilization Plant (WTP) may be present in the liquid waste routed to the Liquid Effluent Retention Facility (LERF) for eventual treatment at the ETF. In addition, a recent integrated melter test performed at the Vitreous State Laboratory (VSL) at The Catholic University of America (CUA) showed the possibility that a significant fraction (>50%) of the total iodine in the melter feed could be present in the aqueous waste stream destined for the ETF. This stream represents a combination of the Effluent Management Facility (EMF) evaporator overhead condensate and the liquid waste from the WTP off-gas caustic scrubber. Higher levels of 129 I in this stream could affect the LERF and ETF Hazard Categorizations as well as the acceptability of the solidified ETF liquid secondary waste brine for disposal at the IDF. Accordingly, there is a need to investigate and develop potential methods and processes to mitigate this risk. Washington River Protection Solutions, LLC (WRPS) tasked Atkins and VSL to perform development and testing work to evaluate potential methods for removal of iodine species from the waste stream routed to the LERF. In particular, the testing investigated the use of an Atkins-SpinIonic™ Rotating Bed Reactor (RBR) system as a potential alternative to conventional column-based ion exchange or absorption processes. The present report provides results obtained from testing with an RBR system for the removal of iodine from simulants of the projected WTP waste stream that discharges to the LERF.

12 MANAGEMENT OF RADIOACTIVE AND NON-RADIOACTIVE W↗

Design new epoxy nanocomposite coatings based on metal vanadium oxy-phosphate M 0.5 VOPO 4 for anti-corrosion applications

Epoxy nanocomposite coatings are an essential way to protect petroleum storage tanks from corrosion. For this purpose, the new nanocomposite epoxy coatings (P-M/epoxy composites) have been successfully designed. The P-M/epoxy composites are based on the metal vanadium oxy-phosphate M 0.5 VOPO 4 (where M = Mg, Ni, and Zn). The function of P-M/epoxy composites as anti-corrosion coatings was explored using electrochemical and mechanical tests. Using electrochemical impedance spectroscopy (EIS), it has been noticed that the pore resistance and polarization resistance of the P-M/epoxy composites remain higher as compared to the neat epoxy. The P-M/epoxy composites have the greatest impact on the cathodic dis-bonded area and water absorption. Besides, P-M/epoxy composites exhibit a very high order of mechanical properties. Further, Mg 0.5 VOPO 4 has the greatest effect on the anti-corrosion properties of epoxy coating followed by Zn 0.5 VOPO 4 and Ni 0.5 VOPO 4 . All these properties lead to developing effective anti-corrosion coatings. Thus, the net result from this research work is highly promising and provides a potential for future works on the anti-corrosion coating.

37 INORGANIC, ORGANIC, PHYSICAL, AND ANALYTICAL CH↗

Experimental Investigation of the Heat Transfer between Finned Tubes and a Bubbling Fluidized Bed with Horizontal Sand Mass Flow

The sandTES technology utilizes a fluidized bed counter current heat exchanger for thermal energy storage applications. Its main feature is an imposed horizontal flow of sand (SiO2) particles fluidized by a vertical air flow across a heat exchanger consisting of several horizontal rows of tubes. Past international research on heat transfer in dense fluidized beds has focused on stationary (stirred tank) systems, and there is little to no information available on the impact of longitudinal or helical fins. Previous pilot plant scale experiments at TU Wien led to the conclusion that the currently available correlations for predicting the heat transfer coefficient between the tube surface and the surrounding fluidized bed are insufficient for the horizontal sand flow imposed by the sandTES technology. Therefore, several smaller test rigs were designed in this study to investigate the influence of different tube arrangements and flow conditions on the external convective heat transfer coefficient and possible improvements by using finned tubes. It could be shown that helically finned tubes in a transversal arrangement, where the horizontal sand flow is perpendicular to the tube axes, allows an increase in the heat transfer coefficient per tube length (i.e., the virtual heat transfer coefficient) by a factor of 3.5 to about 1250 W/m2K at ambient temperature. Based on the literature, this heat transfer coefficient is expected to increase at higher temperatures. The new design criteria allow the design of compact, low-cost heat exchangers for thermal energy storage applications, in particular electro-thermal energy storage.

25 ENERGY STORAGE↗

Biocatalytic Yarn for Peroxide Decomposition with Controlled Liquid Transport

In this study, a robust biocatalytic yarn with controllable liquid transport properties is created by coating thin layers of chitosan containing catalase onto a cellulosic yarn. The resulting material integrates enzyme catalytic functionality with protective coating properties of chitosan and structural functionality of the textile. Mild immobilization conditions and good affinity between the two polysaccharides minimize enzyme inactivation during the preparation steps and prevent enzyme from leaching during peroxide decomposition testing and washing, providing a novel and versatile enzyme immobilization strategy. The catalytic efficiency of enzymes in a reaction containing solid, liquid, and gas phases is facilitated when dissolved enzyme substrate is transported by liquid flowing through the coated textile structure. The flow-through configuration decomposes at least two times more peroxide in a twenty-times smaller reaction zone volume compared to a stirred tank configuration. Liquid transport through the yarn and liquid spatial distribution within the yarn are investigated by in situ neutron radiography and neutron computed tomography, revealing a constrained wicking mechanism that benefits biocatalytic yarn performance. This new class of sustainable and flexible biocatalytic textile matrices has beneficial multifunctional properties, not previously described, that are applicable for numerous small- and large-scale applications including controlled flow reactors and reactive filtration.

36 MATERIALS SCIENCE↗

Assessment of the Effectiveness of Three Aftermarket Gasoline Fuel Stabilizers in Preventing Gum Formation and Loss of Oxidation Stability

We note that fuel stabilizers have long been marketed to consumers to prevent oxidation and gum formation. In the past, gasoline storage for long periods of time was commonly limited to off-road equipment that was used infrequently. Cars and trucks that were driven regularly consumed the fuel in their tanks rapidly enough to avoid excessive fuel aging. However, plug-in hybrid electric vehicles (PHEVs) may be operated frequently without engine operation, raising the possibility that fuel may be stored in the tank for longer periods of time. Studies of the oxidation of gasoline have provided scientific understanding of the process, but there is little if any scientifically backed information aimed at aiding consumers in assessing the need to use an aftermarket fuel stabilizer if they anticipate lengthy periods of fuel storage in their fuel tank. This study was conceived to address this information gap by evaluating three aftermarket stabilizer products alongside baseline gasoline using sealed samples over a period of 12 months of aging. The aging was carried out under ambient temperature conditions with an additional series of samples kept in refrigerated storage. Analyses of vapor pressure, copper strip corrosion, oxidation stability, existent gums, and potential gums were carried out using standard ASTM tests to evaluate the samples as aging progressed. The results show that baseline gasoline remained compliant with relevant specifications to at least 12 months of aging without the use of aftermarket stabilizer additives. Use of two of the aftermarket additives increased the oxidation stability of the baseline gasoline, but this added stability was not necessary to comply with gasoline specifications.

42 ENGINEERING↗

Analysis of DWPF Sludge Batch 6 (Macrobatch 7): Pour Stream Glass Samples

The Defense Waste Processing Facility (DWPF) began processing Sludge Batch 6 (SB6), also referred to as Macrobatch 7 (MB7), in June 2010. SB6 is a blend of the heel of Tank 40 from Sludge Batch 5 (SB5), H-Canyon Np transfers and SB6 that was transferred to Tank 40 from Tank 51.1 SB6 was processed using Frit 418. Sludge is received into the DWPF Chemical Processing Cell (CPC) and is processed through the Sludge Receipt and Adjustment Tank (SRAT) and Slurry Mix Evaporator Tank (SME). The treated sludge slurry is then transferred to the Melter Feed Tank (MFT) and fed to the melter. During processing of each sludge batch, the DWPF is required to take at least one glass sample to meet the objectives of the Glass Product Control Program (GPCP) and to complete the necessary Production Records so that the final glass product may be disposed of at a Federal Repository. The DWPF requested various analyses of radioactive glass samples obtained from the melter pour stream during processing of SB6 as well as reduction/oxidation (REDOX) analysis of MFT samples to determine the impact of Argon bubbling. Sample analysis followed the Task Technical and Quality Assurance Plan (TTQAP) and an Analytical Study Plan (ASP). Four Pour Stream (PS) glass samples and two MFT slurry samples were delivered to the Savannah River National Laboratory (SRNL) from the DWPF. Table 1-1 lists the sample information for each pour stream glass sample. SB6 PS3 (S03472) was selected as the official pour stream sample for SB6 and full analysis was requested. This report details the visual observations of the as-received SB6 PS No.3 glass sample as well as results for the chemical composition, Product Consistency Test (PCT), radionuclide content, noble metals, and glass density. REDOX results will be provided for all four pour stream samples and vitrified samples of MFT-558 and MFT-568A. Where appropriate, data from other pour stream samples will be provided.

12 MANAGEMENT OF RADIOACTIVE AND NON-RADIOACTIVE W↗

Smart Composite Pressure Vessels (SCPV) with Integrated Health Monitoring

The U.S. Department of Energy (DOE) is promoting and developing more energy efficient and environmentally friendly technologies that will enable America to use less petroleum. Hydrogen fuel cells – which directly convert the chemical energy in hydrogen to electricity with only water and heat as byproducts – are a very attractive solution that can enable this to happen. To date, DOE's efforts have culminated in commercial demonstration of on-board vehicular hydrogen storage systems that can allow for a driving range of greater than 300 miles. This requires storing 5 Kgs of hydrogen onboard a light vehicle. In order to store this quantity of hydrogen, the hydrogen gas needs to be stored in a composite overwrapped pressure vessel (COPV) at a very high internal pressure. The objective of the program was to demonstrate continuous and predictable health-monitoring of composite pressure vessels. A higher confidence in the operational safety of the vessels will lead to reduced burst factor of safety imposed by regulatory standards and hence will help reduce the structural wall thickness that drives the cost of the vessel. Highly optimized Type III (metal lined) and Type IV (polymer lined) COPVs that are manufactured using filament winding process have been designed and qualified for the above mentioned application. However, the main structural component of the COPVs is carbon fiber and the high cost of carbon fiber composite in a pressure vessel is a primary challenge in reducing the cost of gaseous hydrogen storage. Continuous and remote monitoring of structural health of the COPVs as well as optimization of the strength translation of carbon fibers have the potential to allow for reduced factor of safety, thereby reduced amount of carbon and associated cost of the vessel. In the current program, the project team including Steelhead Composites (SHC), University of Tennessee, Knoxville (UTK), Teijin Carbon America, Oak Ridge National Laboratory (ORNL) and LUNA designed, fabricated, and tested smart composite pressure vessels with integrated sensors. Iterative loops of design and testing using coupons, subscale STEB vessels and full size vessels proved that a new generation of high performance carbon fiber can be used for efficient design of Type 3 vessels for H2 storage. Novel analysis techniques were developed to predict the initiation and propagation of interlaminar damage inside the composite shell due to impact damage, a real threat in practical operation. Such an analysis scheme is typically not used in tank design but is an essential tool for health monitoring of composite vessels. Remote sensing of the key signatures of the tank’s operating parameters such as pressure, acceleration and humidity was demonstrated using a unique device that can wirelessly transmit and stream the data to a remote server. Fiber optic sensors were successfully integrated during fabrication of the tanks. These sensors provide a wealth of information regarding the structural health of the vessel when it is subsequently pressurized or subjected to impact damage. Excellent correlation was demonstrated between the fiber optic sensor and mechanical strain gage data, and between the measurements and analytical predictions.

08 HYDROGEN↗

Progress Report on Model Development for Aerosol Transport through Divergent Cracks Paths

This report summarizes the progress in developing a phenomenological model of aerosol transport, deposition, and plugging through microchannels. The purpose of this effort is to introduce to a user community—involving researchers, regulators, and industry—a generic, reliable numerical model for the prediction of aerosol transport while accounting for potential deposition and plugging of the leak paths to model spent nuclear fuel (SNF) release from postulated Stress Corrosion Cracks in canisters under storage or transportation. Current work focuses on expanding the model to predict aerosol (and gas) flow through complex microchannel (nozzle) geometries in addition to the rectangular and cylindrical geometries, as we approach more realistic Stress Corrosion Crack conditions. In this regard, a divergent nozzle geometry, used at Sandia National Laboratories (SNL) for testing aerosol release and retention (Durbin et al. 2021), was added to the model. The model was then validated with blowdown data for the particular microchannel, from experiments conducted at SNL. The report also presents preliminary non-benchmarked aerosol penetration fraction and mass flow rate for a monodisperse 10-micron (AED) particle concentration of 1.7e-08 kg/m 3 being released through the divergent microchannel geometry from the SNL’s aerosol experimental tank setup.Future work will involve validating the aerosol model and updating the model’s Graphical User Interface (GUI) to include the divergent nozzle geometry. This is expected to help stakeholders perform quick and easy first principles calculations without needing to understand the underlying MATLAB script.

11 NUCLEAR FUEL CYCLE AND FUEL MATERIALS↗

Basic Design Layout of a Modular Pumped Hydro Teaching Unit

This work was originally completed in July 2015 as a proposal to Santa Fe Community College (SFCC) for their engineering program and a follow up to a feasibility study completed for the Community College the year earlier as indicated below. The work was ahead of its time and funding was hard to obtain to implement a project. This work is now being formally released for distribution to a wider audience based on the evolving circumstances in greater society that now favor this approach with funding more readily available. Due to the distribution outside of SFCC, specific architectural drawing sets of the pertinent buildings called out in the design have been removed. No changes to the design have been made. The design layout utilizing a building is not meant to limit the implementation of the design. The elevation difference required may be obtained with a building, a small hill, jacking up the upper tank, or similar means. The design presented is a basic design, identifying major components and how they are connected together. The user may change components under their own liability. All local applicable codes and standards must be followed when building an actual unit, under the authority of a responsible engineer or owner. Appropriate measures must be followed to protect people from hazards such as electricity, water pressure, and general construction. A leak test to verify water tightness of the system should be conducted prior to any operations. The vision of this design is to allow a class of 10 to 15 students to construct the assembly within a month or so time period, and then learn to operate the assembly at their school location under the guidance of their instructor. This will allow the students to learn about the practical concept of storing electricity with water, and gain a hands on experience of the real world challenges faced with full Modular Pumped Hydro Projects.

13 HYDRO ENERGY↗

MSTL Re-Start Phase 1.5 Project Final Report

This document provides an overview of re-start efforts at Sandia National Laboratories (SNL), National Solar Thermal Test Facility (NSTTF), for the SNL Molten Salt Test Loop (MSTL). MSTL is one of the world’s only industrial-scale molten salt test systems, capable of testing commercial-scale thermal hydraulic equipment at an industrial scale, required for confident bankability of products. This work was facilitated as part of the Phase 1 re-start effort for facilitating forensics assessments to inform final refurbishments and upgrades costs and schedule information for revitalizing MSTL for use during a separate Phase 2 effort. This work was facilitated to further de-risk a Phase 2 effort pertaining to the tank and the pump, which were considered during Phase 1 to be high-risk items for a successful re-start. Impact from a successful re-start will allow SNL and other industrial molten salt systems companies, such as those in the Market Utilization Report provided in the Phase 1 submission package. An objective of this document is to also ensure longevity of utilization of MSTL after re start.

14 SOLAR ENERGY↗

Cesium Removal and Hydraulic Performance Comparisons of CST Ion Exchange Media Batches in Support of the Tank Closure Cesium Removal Project - 20522

Three batches of Crystalline Silicotitanate (CST) ion exchange media have been evaluated for cesium removal efficiency from a Savannah River Site (SRS) High Level Waste (HLW) supernate simulant in support of the Tank Closure Cesium Removal (TCCR) Project, which involves at-tank column waste treatment. Results will be utilized to select the CST media batch to be added to the next TCCR unit columns. Two of the CST media samples were recent production batches and the third was an archived batch studied extensively at SRS nearly two decades ago. The archived CST batch had a significantly smaller average particle diameter than more recent batches. Small-scale (∼23 mL), side-by-side column tests were conducted at 35 deg. C with each of the CST batches using the same simulant at flow rates near 1.2 mL/min (3.0-3.4 CST bed volumes/hr). The cesium ion exchange column performance results were lower than expected for all three CST batches, but the data indicated that 30% more simulant volume and 40% more equivalent CST bed volumes of solution can be processed with the older CST batch prior to reaching the 50% cesium breakthrough point than can be processed with the newer CST batches. Hydraulic evaluations of the CST columns were also conducted in simulant at 24 deg. C to determine the impact of the different particle size distributions and associated bed porosities on frictional pressure drop under dynamic flow conditions. Higher differential pressure drops were observed with the archived CST batch relative to recent production batches, due to the smaller particle size distribution and the packing characteristics of the archived batch. (authors)

12 MANAGEMENT OF RADIOACTIVE AND NON-RADIOACTIVE W↗