Engineering Papers⌕ Search

SEARCH · Engineering Papers

Results for “TEST METHOD”

Search indexed NASA NTRS and DOE OSTI research on propulsion, heat transfer, battery materials and energy systems. Follow report and document links to the original sources.

Quote a phrase for an exact phrase match. Source license links do not imply unrestricted reuse.

At least 433 records · Page 24

New model-independent method to test the curvature of the universe

We propose a new model-independent method to test the cosmic curvature by comparing the proper distance and transverse comoving distance. Using the measurements of the Hubble parameter H(z) and the angular diameter distance d {sub A}, the cosmic curvature parameter Ω{sub K} is constrained to be −0.09 ± 0.19, which is consistent with a flat universe. We also use a Monte Carlo simulation to test the validity and efficiency, and find that our method can give a reliable and efficient constraint on cosmic curvature. Compared with other model-independent methods testing the cosmic curvature, our method can avoid some drawbacks and give a better constraint.

79 ASTRONOMY AND ASTROPHYSICS↗

A Safe Response to Renewable Energy Hazards

The International Association of Fire Fighters (IAFF) and Underwriters Laboratories, LLC (UL) in conjunction with UL Solutions initiated a joint project in 2022 under an agreement with the United States Department of Energy-Office of Energy Efficiency and Renewable Energy (DOE-EERE). This project focused on two separate and important initiatives related to energy efficiency in residential buildings. Initiative 1: Fire Performance on Energy Efficient Exterior Walls. Initiative 2: Firefighting Tactics in Residential Properties with Building Energy Storage Systems (BESS). The project’s first initiative addresses concerns surrounding new technologies with enhanced, energy-efficient exterior walls installed on residential properties. The concerns of fire rapidly traveling vertically up the exterior of these walls were examined. This addressed a growing concern from the first responder community that many times, the fires on the exterior of residential buildings have already evolved into an attic fire by the time of arrival – making it problematic to address the fire scenario. The test plan for Initiative 1 incorporated a modified version of an American Society for Testing and Materials (ASTM) test method, ASTM E2707, Standard Test Method for Determining Fire Penetration of Exterior Wall Assemblies Using a Direct Flame Impingement Exposure, as the foundation of the research. The test method involved a wall structure intended to represent retrofit construction to evaluate how fire would spread vertically or laterally. The second aspect of the UL-IAFF Project focuses on the fire service response to Residential Battery Energy Storage System (RBESS) incidents. These simulation tests were constructed in the large-scale fire test facility at UL Solutions’ Northbrook, IL campus. A baseline test was conducted that involved a test structure with no batteries—shelving units populated with standardized commodities, representing a typical garage with cellulosic and plastic contents. Three additional tests have been conducted to generate data with the contribution of energy storage system (ESS) batteries to compare fire and explosion hazards against the baseline test. Through this work, fire service tactical considerations can be explored. From the data, the team can determine 1) the visual indicators of a residential fire that has involved an RBESS (or, potentially, other large batteries) and 2) the impact of fire service-initiated ventilation of the structure on the fire conditions and explosion risks.

32 ENERGY CONSERVATION, CONSUMPTION, AND UTILIZATI↗

Protostellar formation in rotating interstellar clouds. I - Numerical methods and tests

Attention is given to numerical methods and tests of a series of gravitational hydrodynamics computer codes constructed in order to numerically follow the dynamic collapse of spherically symmetric (1-D), axisymmetric (2-D), and non-axisymmetric (3-D) isothermal interstellar clouds. A spherical harmonic expansion is used to solve the Poisson equation for the gravitational potential. It is shown that the use of explicit donor-cell hydrodynamics on a moving spherical coordinate grid ensures mass and momentum conservation and allows the grid to follow the collapse of the fluid. Finally, the performance of the codes is examined.

Boss, A. P.↗

Acoustic Testing of Flight Hardware Using Loudspeakers: How Much do We Know About This Method of Testing?

Loudspeakers have been used for acoustic qualification of spacecrafts, reflectors, solar panels, and other acoustically responsive structures for more than a decade. Even though a lot of hardware has been acoustic tested using this method, the nature of the acoustic field generated by controlling an ensemble of speakers with and without the hardware in the test volume has not been thoroughly investigated. Limited measurements from some of the recent speaker tests used to qualify flight hardware have indicated significant spatial variation of the acoustic field within the test volume. Also structural responses have been reported to differ when similar tests were performed using reverberant chambers. Unlike the reverberant chamber acoustic test, for which the acoustic field in most chambers is known to be diffuse except below several tens of Hz where acoustic standing waves and large spatial variations exist, the characteristics of the acoustic field within the speaker test volume has not been quantified. It has only been recently that a detailed acoustic field characterization of speaker testing has been made at Jet Propulsion Laboratory (JPL) with involvement of various organizations. To address the impact of non-uniform acoustic field on structures, a series of acoustic tests were performed using a flat panel and a 3-ft cylinder exposed to the field controlled by speakers and repeated in a reverberant chamber. The analysis of the data from this exercise reveals that there are significant differences both in the acoustic field and in the structural responses. In this paper the differences between the two methods are reviewed in some detail and the over- or under-testing of articles that could pose un-anticipated structural and flight qualification issues are discussed. A framework for discussing the validity of the speaker acoustic testing method with the current control system and a path forward for improving it will be provided.

Acoustics↗

In-Situ Ice Adhesion Testing using the Deformed Skin Adhesion Test

There exists a plethora of ice adhesion testing methods such as centrifuge-based methods, push/pull methods, and lap joint shear tests. However, these methods often cannot be done in-situ during an icing spray and require researcher handling/preparation prior to testing. Additionally, many of these methods test ice accretions that are not representative of the ice shapes that grow on airframes which can have unintended consequences such as edge or corner stress concentrations. In order to mitigate the issues present with other ice adhesion tests a novel, hands-free, in-situ test method imbedded into the leading edge of the airfoil has been developed and tested in the NASA Glenn Research Center Icing Research Tunnel. The mechanics of the new test method are discussed with finite element simulations being used to highlight the fundamental mechanics of this test method. The testing procedures used during the experimental test campaign are discussed along with the icing cloud test matrix. Analysis of the force-displacement results highlights the repeatability of the test method with regards to both sample behavior across several days of testing and different ice shapes. The results from first run of the day showed a significant discrepancy from subsequent runs and differential image analysis was used to determine differences in the interfacial bonding states between runs.

Ice Adhesion↗

In-Situ Ice Adhesion Testing using the Deformed Skin Adhesion Test

There exists a plethora of ice adhesion testing methods such as centrifuge-based methods, push/pull methods, and lap joint shear tests. However, these methods often cannot be done in-situ during an icing spray and require researcher handling/preparation prior to testing. Additionally, many of these methods test ice accretions that are not representative of the ice shapes that grow on airframes which can have unintended consequences such as edge or corner stress concentrations. In order to mitigate the issues present with other ice adhesion tests a novel, hands-free, in-situ test method imbedded into the leading edge of the airfoil has been developed and tested in the NASA Glenn Research Center Icing Research Tunnel. The mechanics of the new test method are discussed with finite element simulations being used to highlight the fundamental mechanics of this test method. The testing procedures used during the experimental test campaign are discussed along with the icing cloud test matrix. Analysis of the force-displacement results highlights the repeatability of the test method with regards to both sample behavior across several days of testing and different ice shapes. The results from first run of the day showed a significant discrepancy from subsequent runs and differential image analysis was used to determine differences in the interfacial bonding states between runs.

Ice Adhesion↗

Method of Test for Evaluating Building Performance Simulation Software

ANSI/ASHRAE Standard 140 Method of Test for Evaluating Building Performance Simulation Software specifies the method to test the core competency of building performance simulation (BPS) software, a broad class of software which includes building energy modeling (BEM) software. Standard 140 has been widely used by BEM software vendors to help diagnose and compare the results from the program with other modeling programs. The Standard is also referenced by codes, standards, government programs, and other incentive programs as a part of minimum requirements for qualifying BEM software. The explanatory information, summary tables and figures in this 140 User’s Manual (referred to as “this Manual”) are provided to help users in implementing various suites of tests specified in Standard 140-2023 (referred to in this manual as “Standard 140” or “the Standard”).

97 MATHEMATICS AND COMPUTING↗

Repeatability and Reproducibility of Compression Strength Measurements Conducted According to ASTM E9

Ten commercial laboratories participated in an interlaboratory study to establish the repeatability and reproducibility of compression strength tests conducted according to ASTM International Standard Test Method E9. The test employed a cylindrical aluminum AA2024-T351 test specimen. Participants measured elastic modulus and 0.2 % offset yield strength, YS(0.2 % offset), using an extensometer attached to the specimen. The repeatability and reproducibility of the yield strength measurement, expressed as coefficient of variations were cv(sub r)= 0.011 and cv(sub R)= 0.020 The reproducibility of the test across the laboratories was among the best that has been reported for uniaxial tests. The reported data indicated that using diametrically opposed extensometers, instead of a single extensometer doubled the precision of the test method. Laboratories that did not lubricate the ends of the specimen measured yield stresses and elastic moduli that were smaller than those measured in laboratories that lubricated the specimen ends. A finite element analysis of the test specimen deformation for frictionless and perfect friction could not explain the discrepancy, however. The modulus measured from stress-strain data were reanalyzed using a technique that finds the optimal fit range, and applies several quality checks to the data. The error in modulus measurements from stress-strain curves generally increased as the fit range decreased to less than 40 % of the stress range.

Luecke, William E.↗

Environmental Stress Testing of the Single Sample Cylinder: A Proven Consensus Standard for Internal Gas Analysis (IGA) or Residual Gas Analysis (RGA)

In August 2008, Schuessler Consulting was contracted by NASA GSFC in support of the NASA Electronic Parts and Packaging (NEPP) program to perform two separate studies on moisture laden air in a stainless steel cylinder that had been designed to become a consensus standard for Test Method 1018. This Test Method was originally released for hybrids under Mil. Std. 883 but was quickly utilized on other microelectronic devices under the auspice of Mil. Std. 750. The cylinder had subsequently been fabricated for the 750 community. It was back-filled with moist air and subsequently analyzed over a period of time under a previous NASA contract. It had been shown that moisture in the 4000 - 5000 ppm range could be analyzed rather precisely with a mass spectrometer, commonly referred to as a Residual Gas Analyzer (RGA). The scope of this study was to ascertain if the composition and precision varied as a function of thermal shock at sub-zero temperatures and whether there was consensus when the standard was submitted to other RGA units. It was demonstrated and published that the consensus standard would yield precise RGA data for moisture within +/- 1% when optimized for a given RGA unit. It has been subsequently shown in this study at Oneida Research Services, that sub-zero storage did not affect that precision when a well-defined protocol for the analysis was followed. The consensus standard was taken to a second facility for analysis where it was found that moisture adsorption on the transfer lines caused precision to drop to +/- 12%. The Single Sample Cylinder (SSC) is a one liter stainless steel cylinder with associated sampling valves and has considerable weight and volume. But this considerable size allows for approximately 300 gas samples of the same composition to be delivered to any RGA unit. Lastly, a smaller cylinder, approximately 75 cc, of a second consensus standard was fabricated and tested with a different mix of fixed gases where moisture was kept in the 100 ppm range. This second standard has the potential of providing 30 gaseous samples and can be readily shipped to any analytical facility that desires to generate comparison RGA data. A series of comparison residual gas analyses was performed at the Honeywell Federal Manufacturing & Technologies facility in the National Nuclear Facility Administration s plant in Kansas City to complete this project. It was shown that improvements in the precision of a given RGA unit can be done by controlling the cycle time for each analysis and increasing analysis temperatures to minimize moisture adsorption. It was also found that a "one time event" in the subzero storage of the large SSC did not effect the units ability to continuously supply precise samples of the same chemistry, however the "event" caused a permanent +8% shift in the reported value of the moisture content. Lastly, a set of SSC RGA results was plotted on a common graph with DSCC "correlation study" RGA data. The result demonstrates the ability of the SSC to remove many of the individual variances that single, individual samples introduce. The consensus standards are now in storage at Oneida Research Services, one of the DSCC certified houses that does RGA to Military Standards, where they await future studies. The analytical data and the operational parameters of the instruments used are provided in the following discussion. Limitations and suggested means for improvement of both precision and accuracy are provided.

Schuessler, Philipp WH↗

Method development for thermal analyses testing on Reillex HPQ resin using the advanced reactive system screening tool (ARSST)

Reillex™ HPQ resin was developed by Los Alamos Laboratory and Reilly Industries Inc. in an effort to increase safety and process efficiency during the recovery and purification of plutonium. Ionac™ A-641, another strong base macroporous anion exchange resin used in the nuclear industry, was known to undergo a runaway reaction in hot nitric acid solutions. Because of this, an extensive amount of thermal analyses testing on the Reillex™ HPQ resin in SRNL was performed in 1999-2001 prior to use. A report on the thermal stability qualification of the Reillex™ HPQ resin in 8M (35%) and 12M (53%) HNO 3 was reported in 2000. In 2001, the reactivity of Reillex™ HPQ resin in 14.4M (64%) HNO 3 was evaluated. In January of 2001, thermal stability scoping tests were performed on irradiated Reillex™ HPQ resin in 14.4M (64%) HNO 3 (as a worst case scenario) and the results sent to Fauske and Associates to calculate a rupture disk size for the HB-Line resin column. A technical report by Fauske and Associates was issued in February 2001 recommending a 2.0” vent line with a rupture disk set pressure of 60 psig. This calculation was based on ARSST thermal analyses scoping tests at SRNL in which 4 grams of dried resin and 6.0 grams of 64% nitric acid in a 10 gram test cell, produced a maximum pressure rate (dP/dt) of 720 psi/min (12 psi/sec) and a maximum temperature of 250 °C. In 2015, a new batch of Reillex™ HPQ resin was manufactured by Vertellus Industries. A test sample of the resin was sent to SRNL to perform acceptance and qualification thermal stability testing using the ARSST. During these tests, method development was performed to ensure that a representative resin to acid ratios were used while running the tests in the ARSST. Fauske and Associates recommended to either use a full test cell representative of the HB-Line column or a 10 gram sample in the test cell that was representative of the ratios of resin to nitric acid in the actual HB-Line column. An observation was made during method development testing that the 4 grams of resin to 6 grams of 64% acid ratio used in 2001 to determine the rupture disk size did not entirely wet the resin and was not representative of the actual HB-Line column. The results of this study raised questions as to whether the ratio of 4 grams of resin to 6 grams of 64% nitric acid recommended by Fauske and Associates in 2001 was the correct ratio.

36 MATERIALS SCIENCE↗

Advanced Capabilities for Wind Tunnel Testing in the 21st Century

Wind tunnel testing methods and test technologies for the 21st century using advanced capabilities are presented. These capabilities are necessary to capture more accurate and high quality test results by eliminating the uncertainties in testing and to facilitate verification of computational tools for design. This paper discusses near term developments underway in ground testing capabilities, which will enhance the quality of information of both the test article and airstream flow details. Also discussed is a selection of new capability investments that have been made to accommodate such developments. Examples include advanced experimental methods for measuring the test gas itself; using efficient experiment methodologies, including quality assurance strategies within the test; and increasing test result information density by using extensive optical visualization together with computed flow field results. These points could be made for both major investments in existing tunnel capabilities or for entirely new capabilities.

Kegelman, Jerome T.↗

A low cost method of testing compression-after-impact strength of composite laminates

A method was devised to test the compression strength of composite laminate specimens that are much thinner and wider than other tests require. The specimen can be up to 7.62 cm (3 in) wide and as thin as 1.02 mm (.04 in). The best features of the Illinois Institute of Technology Research Institute (IITRI) fixture are combined with an antibuckling jig developed and used at the University of Dayton Research Institute to obtain a method of compression testing thin, wide test coupons on any 20 kip (or larger) loading frame. Up to 83 pct. less composite material is needed for the test coupons compared to the most commonly used compression-after-impact (CAI) tests, which calls for 48 ply thick (approx. 6.12 mm) test coupons. Another advantage of the new method is that composite coupons of the exact lay-up and thickness of production parts can be tested for CAI strength, thus yielding more meaningful results. This new method was used to compression test 8 and 16 ply laminates of T300/934 carbon/epoxy. These results were compared to those obtained using ASTM standard D 3410-87 (Celanese compression test). CAI testing was performed on IM6/3501-6, IM7/SP500 and IM7/F3900. The new test method and associated fixture work well and is a valuable asset to MSFC's damage tolerance program.

Nettles, Alan T.↗

Comparative Study of Impedance Eduction Methods: DLR Tests and Methodology - Part 1

The absorption efficiency of acoustic liners used in aircraft engines is characterized by the acoustic impedance. World wide, many grazing ow test rigs and eduction methods are available that provide values for that impedance. However, a direct comparison and assessment of the data of the di erent rigs and methods is often not possible because test objects and test conditions are quite di erent. Only a few papers provide a direct comparison. Therefore, this paper together with a companion paper, present data measured with a reference test object under similar conditions in the DLR and NASA grazing ow test rigs. Additionally, by applying the in-house methods Liner Impedance Non-Uniform ow Solving algorithm (LINUS, DLR) and Convected Helmhholtz Equation approach (CHE, NASA) on the data sets, similarities and differences due to underlying theory are identi ed and discussed.

Busse-Gerstengarbe, Stefan↗

Environmentally safe aviation fuels

In response to the Air Force directive to remove Ozone Depleting Chemicals (ODC's) from military specifications and Defense Logistics Agency's Hazardous Waste Minimization Program, we are faced with how to ensure a quality aviation fuel without using such chemicals. Many of these chemicals are found throughout the fuel and fuel related military specifications and are part of test methods that help qualify the properties and quality of the fuels before they are procured. Many years ago there was a directive for military specifications to use commercially standard test methods in order to provide standard testing in private industry and government. As a result the test methods used in military specifications are governed by the American Society of Testing and Materials (ASTM). The Air Force has been very proactive in the removal or replacement of the ODC's and hazardous materials in these test methods. For example, ASTM D3703 (Standard Test Method for Peroxide Number of Aviation Turbine Fuels), requires the use of Freon 113, a known ODC. A new rapid, portable hydroperoxide test for jet fuels similar to ASTM D3703 that does not require the use of ODC's has been developed. This test has proved, in limited testing, to be a viable substitute method for ASTM D3703. The Air Force is currently conducting a round robin to allow the method to be accepted by ASTM and therefore replace the current method. This paper will describe the Air Force's initiatives to remove ODC's and hazardous materials from the fuel and fuel related military specifications that the Air Force Wright Laboratory.

Liberio, Patricia D.↗

Assessment of Literature Related to Combustion Appliance Venting Systems

In many residential building retrofit programs, air tightening to increase energy efficiency is constrained by concerns about related impacts on the safety of naturally vented combustion appliances. Tighter housing units more readily depressurize when exhaust equipment is operated, making combustion appliances more prone to backdraft or spillage. Several test methods purportedly assess the potential for depressurization-induced backdrafting and spillage, but these tests are not robustly reliable and repeatable predictors of venting performance, in part because they do not fully capture weather effects on venting performance. The purpose of this literature review is to investigate combustion safety diagnostics in existing codes, standards, and guidelines related to combustion appliances. This review summarizes existing combustion safety test methods, evaluations of these test methods, and also discusses research related to wind effects and the simulation of vent system performance. Current codes and standards related to combustion appliance installation provide little information on assessing backdrafting or spillage potential. A substantial amount of research has been conducted to assess combustion appliance backdrafting and spillage test methods, but primarily focuses on comparing short-term (stress) induced tests and monitoring results. Monitoring, typically performed over one week, indicated that combinations of environmental and house operation characteristics most conducive to combustion spillage were rare. Research, to an extent, has assessed existing combustion safety diagnostics for house depressurization, but the objectives of the diagnostics, both stress and monitoring, are not clearly defined. More research is also needed to quantify the frequency of test “failure” occurrence throughout the building stock and assess the statistical effects of weather (especially wind) on house depressurization and in turn on combustion appliance venting. Incorporating weather variations and house ventilation system characteristics in existing simulation software may assist such analyses and with developing a more reliable diagnostic for use on-site.

29 ENERGY PLANNING, POLICY, AND ECONOMY↗

Crack-Growth Resistance of in Situ-Toughened Silicon Nitride

The fracture toughness of a commercial, hot-pressed, in situ-toughened silicon nitride with an elongated grain structure is determined by four different testing methods. The fracture toughness is found to be 5.76 +/- 0.27, 8.48 +/- 0.50, 10.16 +/- 0.66, and 10.68 +/- 0.39 MPa x m(exp 1/2), respectively, by indentation crack size measurement, indentation strength, single-edge-precracked-beam, and chevron-notched-beam methods. The discrepancy in fracture toughness between the testing methods is related to R-curve behavior, as measured using the indentation strength technique. These results indicate that there is no unique fracture toughness value and that a fracture toughness testing method with appropriate qualifiers is needed for rising R-curve materials. Therefore, care should be taken in interpreting and utilizing fracture toughness values evaluated from different testing methods if a material exhibits a rising R-curve. Complete characterization of the R-curve may be a prerequisite.

Salem, Jonathan A.↗

An Accelerated Method for Testing Soldering Tendency of Core Pins

An accelerated method for testing die soldering has been developed. High intensity ultrasonic vibrations has been used to simulate the die casting conditions such as high pressure and high impingement speed of molten metal on the pin. Soldering tendency of steels and coated pins has been examined. The results indicate that in the low carbon steel/Al system, the onset of soldering is 60 times faster with ultrasonic vibration than that without ultrasonic vibration. In the H13/A380 system, the onset of soldering reaction is accelerated to 30-60 times. Coating significantly reduces the soldering tendency of the core pins.

36 MATERIALS SCIENCE↗