Engineering Papers⌕ Search

SEARCH · Engineering Papers

Results for “System control”

Search indexed NASA NTRS and DOE OSTI research on propulsion, heat transfer, battery materials and energy systems. Follow report and document links to the original sources.

Quote a phrase for an exact phrase match. Source license links do not imply unrestricted reuse.

At least 433 records · Page 24

Upgrade of hardware controls for the STAR experiment at RHIC

The STAR experiment has been delivering significant physics results for more than 20 years. Stable operation of the experiment was achieved by using a robust controls system based on the Experimental Physics and Industrial Control System (EPICS). Now an object-oriented approach with Python libraries, adapted for EPICS software, is going to replace the procedural-based EPICS C libraries previously used at STAR. Advantages of the new approach include stability of operation, code reduction and straightforward project documentation. The first two sections of this paper introduce the STAR experiment, give an overview of the EPICS architecture, and present the use of Python for controls software. Therefore, specific examples, as well as upgrades of user interfaces, are outlined in the following sections.

73 NUCLEAR PHYSICS AND RADIATION PHYSICS↗

Active Aerodynamic Load Control for Wind Turbines

The goal of this project was to develop and demonstrate an advanced dielectric barrier discharge (DBD) plasma actuator technology. We set out to demonstrate the efficacy and impact of the new actuator technology as a key component of an active load control system for wind turbines. A DBD plasma actuator consists of a thin layer of dielectric material separating a pair of offset electrodes. One of those electrodes is embedded between the dielectric layer and a non-conductive substrate, while the other is exposed to air. When driven by an appropriate high voltage waveform, the device ionizes the air near the surface of the dielectric and adjacent to the exposed electrode. Collisions between the ions in the plasma and neutral air molecules result in a wall-jet – a region of induced air velocity that can be used to modify the flow around a lifting body. Use of the device near the trailing edge of a wind turbine blade, designed in such a way as to amplify the effects of the flow-modifying device, can result in large changes to the global forces experienced by the blade. Because of the fast response time of the device, it can allow the turbine to react in real time to changes in the wind associated with turbulence, wind shear, gusts, and the like, when paired with appropriate sensors and control algorithms. The goal of this project was to increase the capacity of the device to induce velocity on its surface at the levels required by large, utility-scale wind turbines. The first technical goal was to increase the induced velocity from the current industry-best of about 4 m/s to 10 m/s by modifying the electrical waveform used to drive the device and by introducing a semi-conductive surface coating to control electrostatic charge build-up on the surface. The second goal was to use the device to modify the lift on a representative airfoil in a wind tunnel, demonstrating a reduction in lift coefficient of 0.2 or better. The third goal was to produce an actuator-induced velocity of 20 m/s. Alongside our partners at the University of Texas at Dallas, we also applied modern, advanced design methods to optimize the impact of the technology on the design of wind turbines. We also had planned to install a segmented, active load control system on a test turbine to demonstrate the ability to reduce unsteady aerodynamic forces on the turbine associated with changes in the wind. The highest induced velocity achieved during this research was 11 m/s. However, practical design constraints limited the change in lift coefficient to about 0.12 for a representative airfoil in the wind tunnel at a Reynolds number of 400,000. The primary conclusion is that the plasma actuator control authority remains insufficient for practical purposes when extrapolated to Reynolds numbers over 1 million. The potential impact of the active lift control concept was evaluated through detailed simulations for three wind turbine sizes: a 3.4MW onshore turbine, a 10MW offshore turbine, and a 15MW offshore turbine. A feedback control system was designed for each turbine within two scenarios: one where the active lift control is used as a retrofit capability on the baseline design, and the other where the designers were permitted to “upscale” the turbines in order increase annual energy production. The levelized cost of energy was then evaluated for the range of turbine sizes and design configuration. It was found that the LCOE reduction associated with active lift control fell in the range of 0.7% to 7.2%, with the highest reduction associated with upscaling the 3.4MW turbine.

17 WIND ENERGY↗

Characterisations of the HinOTORI telescope with a three-color imager at Ali Observatory in Western Tibet

HinOTORI is a new telescope supported by an international collaboration project between China and Japan. It is a 50 centimeter telescope equipped with simultaneous three-color imagers (u',R C , and I C bands). It is located at Ali Observatory at an altitude of 5100m. Thanks to the high altitude and extreme dryness, Ali site is one of the most suitable sites for optical astrometry. HinOTORI telescope aims at detecting optical transients such as the counterparts of gravitational wave (GW) sources, supernovae, gamma-ray bursts (GRB) and so on. This paper describes the site information, design of simultaneous three-color optical layout, system instruments and whole control system. We also report some telescope characterisations for three bands (u'/R C /I C ) respectively, such as Hartmann constant (0.49"/0.56"/0.60"), best focus position (3.922/3.920/3.903 mm), PSF FWHM size (3.755/3.328/3.167pixels), total transmittance and limiting magnitude (15.69/17.57/17.05mag, 10 σ 30 seconds exposure time). With different airmass observation data, the atmospheric extinction coefficients of three bands (0.366/0.061/0.026) were also derived.

47 OTHER INSTRUMENTATION↗

Cyber-Physical Resiliency for Wind Power Generation

During the next three years, wind power generation is expected to add more generation capacity to the national electrical grid than any other energy sector. With new wind turbine designs rated power over 10 MW and wind farms reaching over 1 GW capacities, the consequences of cyber-attacks on wind power generation are becoming increasingly more critical. Moreover, the known vulnerabilities of wind turbine control systems and the potential damaging effects of intrusions, motivate an urgent protection improvement for the wind power generation sector. This program has developed a variety of new adaptive defense technologies that enable wind power generation systems to survive sophisticated cyberattacks by enhancing the control systems capabilities of detection, localization, and accommodation. The introduction of these technologies in the on-shore and the emerging off-shore market will result in a significantly more reliable and secure wind power infrastructure.

17 WIND ENERGY↗

Ultrasonic sensors and methods of using the ultrasonic sensors

An ultrasonic sensor comprises a transducer in operable communication with a power source, a waveguide comprising a metal and at least one of a fissile material or a fertile material in operable communication with the transducer and configured to propagate and reflect acoustic waves generated by the transducer, the transducer configured to convert reflected acoustic waves to an electric signal, a thermally insulative material proximate the waveguide, and a control system in operable communication with the transducer, the control system configured to determine at least a temperature of the waveguide based on the reflected acoustic waves. Related methods are also disclosed.

Woolstenhulme, Nicolas E.↗

Space Nuclear Power Autonomous Control Algorithm and Control Element Test Bed

Nuclear thermal rockets are currently NASA’s preferred option for use in a manned mission to Mars in the 2040s. The communication delay between an Earth ground station and a spacecraft heading toward Mars can be up to 20 min. Therefore, controlling the nuclear rocket engine would require either a full-time reactor operator on the mission or an autonomous control system for the reactor. The latter idea of making space nuclear reactors fully autonomous has drawn more interest from stakeholders, but such an autonomous control system must be rigorously tested and validated before it is certified for human use. The cost of a full ground test for a space nuclear reactor is tremendous, so a nonnuclear mock reactor test bed was created to test and validate control elements and control algorithms for space nuclear reactors. The test bed consists of control element hardware that inputs physical measurement data into a reactor emulator to produce the reactor’s performance under steady-state, transient, and fault conditions. The control element hardware consists of six full-sized control drums equipped with servo drives and motors and is instrumented with optical encoders, resolvers, and torque sensors for drum movement characterization. In addition to the drums, a two-phase flow loop was designed and built to mimic the valves and turbomachinery associated with the propellant flow through a nuclear thermal rocket engine; components such as pressure sensors, flow meters, thermocouples, and tachometers are instrumented throughout the loop to characterize the fluid flow, valve, and turbomachinery behavior of the system. The data from the physical hardware (e.g., drum position, propellant flow rates) are input to a nuclear reactor simulator to determine the actual nuclear reactor parameters, and the data are sent back to a control algorithm to complete the control loop. The ability to conduct numerous tests of the control systems and autonomous algorithms can help validate the instrumentation and control aspects for a space nuclear reactor for every possible fault situation.

Wilson, Brandon↗

Multi-Task Reinforcement Learning for Distribution System Voltage Control With Topology Changes

This letter proposes a multi-task deep reinforcement learning (DRL) approach for distribution system voltage regulation considering topology changes via PV smart inverter control. The key idea is to encode the topology as an additional state for the DRL and leverage the multi-task learning scheme for joint learning of all task control policies. Unlike other DRL-based methods, our approach is robust to different topologies. Comparison results on the modified IEEE 123-node system demonstrate the enhanced robustness of the proposed method.

24 POWER TRANSMISSION AND DISTRIBUTION↗

The dynamic synthesis time-lag control for the 1.3 GHz LCLS-II Cryomodule test at Fermilab

The 1.3GHz LCLS-II Cryomodule (CM) has 8 cavities and each cavity has 9 RF cells and 80W heater. The 1.3GHz LCLS-II CM is 12.2-meter-long and contains a total 241.3 liters (equivalent liquid) of liquid helium, which is filling up by the 4KW@2.0K cryogenic plant at the Fermilab Cryomodule Test Facility (CMTF). The dynamic synthesis 2K cryogenic control system is built to control the long time-lag, unstable CM cryogenic system, under different modes operations. A report on the results obtained from the dynamic synthesis long time-lag control in the CMTF 1.3GHz CM test will be presented.

43 PARTICLE ACCELERATORS↗

OT Emulation Data Broker

The OT Emulation Data Broker system allows Simulink models to be connected to an emulated control system network. The package includes a Simulink S-Function that allows communication to the data broker via inter process communication; a data broker, which orchestrates communication between the emulated control system network and the simulation; an endpoint, which facilitates communication between the data broker and PLC's on the control network using ModBus/TCP; and an example PLC structured text files that work with OpenPLC, an open source emulated PLC. Sandia National Laboratories is a multimission laboratory managed and operated by National Technology & Engineering Solutions of Sandia, LLC, a wholly owned subsidiary of Honeywell International Inc., for the U.S. Department of Energy’s National Nuclear Security Administration under contract DE-NA0003525. SAND2021-11479 O

Hahn, Andrew↗

OT Emulation Data Broker v.2.0

SAND2021-11479 O The OT Emulation Data Broker system allows Simulink models to be connected to an emulated control system network. The package includes a Simulink S-Function that allows communication to the data broker via inter process communication; a data broker, which orchestrates communication between the emulated control system network and the simulation; an endpoint, which facilitates communication between the data broker and PLC's on the control network using ModBus/TCP; and an example PLC structured text files that work with OpenPLC, an open source emulated PLC. Sandia National Laboratories is a multimission laboratory managed and operated by National Technology & Engineering Solutions of Sandia, LLC, a wholly owned subsidiary of Honeywell International Inc., for the U.S. Department of Energy’s National Nuclear Security Administration under contract DE-NA0003525.

Hahn, Andrew↗

Integrated Framework of Vehicle Dynamics, Instabilities, Energy Models, and Sparse Flow Smoothing Controllers

This work presents an integrated framework of: vehicle dynamics models, with a particular attention to instabilities and traffic waves; vehicle energy models, with particular attention to accurate energy values for strongly unsteady driving profiles; and sparse Lagrangian controls via automated vehicles, with a focus on controls that can be executed via existing technology such as adaptive cruise control systems. This framework serves as a key building block in developing control strategies for human-in-the-loop traffic flow smoothing on real highways. In this contribution, we outline the fundamental merits of integrating vehicle dynamics and energy modeling into a single framework, and we demonstrate the energy impact of sparse flow smoothing controllers via simulation results.

Lee, Jonathan W.↗

System and method for occupancy-driven register airflow control

An HVAC register airflow control system and an air flow control method are provided. A housing of the system is in fluid communication with an air source for supplying an airflow. The housing includes an air outlet to the enclosed space. A detection sensor detects occupancy information of the enclosed space. A controller generates a control signal based on the occupancy information and controls the shape change of a damper made of a shape memory material. The damper is controlled to switch between a first operative configuration for preventing the airflow from entering the enclosed space and a second operative configured for permitting the airflow to enter the enclosed space.

Wang, Ya↗

Virtual to Physical: Reinforcement Learning to Optimize SNS Particle Accelerator Controls

Complex accelerators must have control systems that can handle dynamic nonlinear environments. This makes traditional control methods unsuitable as they can struggle to adapt to these uncertainties. This provides an ideal environment for reinforcement learning algorithms as they are adaptable and generalizable. We present a reinforcement learning pipeline that can effectively handle the dynamics of a complex accelerator. We test and prove our pipelines capabilities on multiple environments including the Spallation Neutron Source (SNS) and the Beam Test Facility (BTF) at Oakridge National Lab (ORNL). Due to the limited time available to train an online algorithm like reinforcement learning on a real accelerator, we utilize a virtual twin accelerator (VIRAC) developed by ORNL to pretrain the policy and show its ability to converge in the virtual environment. We then test the adaptability of the pretrained RL model by applying it on the real accelerator and comparing the results. Utilizing our Scientific Optimization and Controls Toolkit (SOCT) and open-source standards such as Gymnasium we create and solve for a MEBT orbit correction problem in the SNS and an emittance maximization problem in the BTF. We show how Twin Delayed Deep Deterministic Policy Gradient (TD3) can solve this optimization environment in the virtual accelerator and transfer this policy onto the real accelerator for inference and model retraining. We show how reinforcement learning can be utilized as a control system for complex accelerators and provide a model pipeline for how an implementation performs and can be adapted to new accelerator control problems.

Kasparian, Armen [Thomas Jefferson National Accele↗

ARCADE Technical Pathway and Industry Impact

The Advanced Reactor Cyber Analysis and Development Environment (ARCADE) simplifies the evaluation and assessment of robustness factor and cyber resilience that support secure-by-design for advanced reactor nuclear power plants. In this manner, ARCADE supports risk-informed performance based (RIPB) evaluations of cybersecurity through its integration of plant physics with high-fidelity emulations of control systems. This cross domain approach enables comprehensive analysis of control system sensitivities, cyber-attack scenarios, and their consequences. ARCADE has been custom developed to meet the demands identified in Tier 1 of the Tiered Cyber Analysis (TCA) as outlined in NRC Draft Regulation Guide (RG) 5.96, which provides a RIPB cybersecurity approach for new reactors.

97 MATHEMATICS AND COMPUTING↗

Cooling charge determination for a local thermal management system

A system and method for estimating the state of charge, i.e., the amount of cooling remaining, in a latent heat thermal storage module of a local environmental control system. The local environmental control system stores cooling energy at night by freezing a latent heat phase change material (PCM), and then releasing the stored cooling energy by removing heat from room air flowing through the PCM during the day. Differential temperature sensors are used measure the air temperature drop across the latent thermals storage unit and the fan voltage, which is directly related to fan air flow rate, is sampled. A controller is programmed to determine the charging state from these measurements.

Khalifa, H. Ezzat↗

Boron injection system for controlling a nuclear reaction by delivering boron into a containment vessel

A nuclear power system includes a reactor vessel that includes a reactor core mounted within a volume of the reactor vessel. The reactor core includes one or more nuclear fuel assemblies configured to generate a nuclear fission reaction. The nuclear power system further includes a containment vessel sized to enclose the reactor vessel such that an open volume is defined between the containment vessel and the reactor vessel. A boron injection system is positioned in the open volume of the containment vessel and includes an amount of boron sufficient to stop the nuclear fission reaction or maintain the nuclear fission reaction at a sub-critical state. The boron injection system is positioned to deliver the amount of boron into the open volume.

Linik, Larry↗

Analysis of Line Distance Elements for Various Ibr Controllers and System Conditions

The large-scale penetration of inverter-based resources in power systems has challenged protection engineers because of the different fault behaviors these sources provide compared to conventional generation systems. The main challenges include a low level of fault current magnitude, unpredictable angles of sequence currents, and lack of inertia that can lead to maloperation of conventional phasor-based protection elements. This paper presents a sensitivity analysis of transmission line distance protection elements during phase-to-ground and phase-to-phase faults for different inverter controllers and power system conditions. It also summarizes which line protection elements remain secure near IBR terminations and identifies the ones affected by the inverter-based response. The paper concludes by highlighting that regulating negative-sequence current injection during the fault aids correct protection decisions, but does not address the entire challenge. Finally, alternative protection elements to those affected by the inverter fault response are discussed.

24 POWER TRANSMISSION AND DISTRIBUTION↗