Engineering Papers⌕ Search

SEARCH · Engineering Papers

Results for “System Operator”

Search indexed NASA NTRS and DOE OSTI research on propulsion, heat transfer, battery materials and energy systems. Follow report and document links to the original sources.

Quote a phrase for an exact phrase match. Source license links do not imply unrestricted reuse.

At least 433 records · Page 24

Evaluating the Impacts of Real-Time Pricing on the Cost and Value of Wind Generation

One of the costs associated with integrating wind generation into a power system is the cost of redispatching the system in real-time due to day-ahead wind resource forecast errors. One possible way of reducing these redispatch costs is to introduce demand response in the form of real-time pricing (RTP), which could allow electricity demand to respond to actual real-time wind resource availability using price signals. A day-ahead unit commitment model with day-ahead wind forecasts and a real-time dispatch model with actual wind resource availability is used to estimate system operations in a high wind penetration scenario. System operations are compared to a perfect foresight benchmark, in which actual wind resource availability is known day-ahead. The results show that wind integration costs with fixed demands can be high, both due to real-time redispatch costs and lost load. It is demonstrated that introducing RTP can reduce redispatch costs and eliminate loss of load events. Finally, social surplus with wind generation and RTP is compared to a system with neither and the results demonstrate that introducing wind and RTP into a market can result in superadditive surplus gains.

17 WIND ENERGY↗

Clustering execution in a processing system to increase power savings

Embodiments relate to clustering execution in a processing system. An aspect includes accessing a control flow graph that defines a data dependency and an execution sequence of a plurality of tasks of an application that executes on a plurality of system components. The execution sequence of the tasks in the control flow graph is modified as a clustered control flow graph that clusters active and idle phases of a system component while maintaining the data dependency. The clustered control flow graph is sent to an operating system, where the operating system utilizes the clustered control flow graph for scheduling the tasks.

97 MATHEMATICS AND COMPUTING↗

Clustering execution in a processing system to increase power savings

Embodiments relate to clustering execution in a processing system. An aspect includes accessing a control flow graph that defines a data dependency and an execution sequence of a plurality of tasks of an application that executes on a plurality of system components. The execution sequence of the tasks in the control flow graph is modified as a clustered control flow graph that clusters active and idle phases of a system component while maintaining the data dependency. The clustered control flow graph is sent to an operating system, where the operating system utilizes the clustered control flow graph for scheduling the tasks.

97 MATHEMATICS AND COMPUTING↗

ADMS State of the Industry and Gap Analysis

An Advanced distribution management system (ADMS) is a platform for optimized distribution system operational management. This platform comprises of distribution management system (DMS) applications, supervisory control and data acquisition (SCADA), outage management system (OMS), and distributed energy resource management system (DERMS). One of the primary objectives of this work is to study and analyze several ADMS component and auxiliary systems. All the important component and auxiliary systems, SCADA, GISs, DMSs, AMRs/AMIs, OMSs, and DERMS, are discussed in this report. Their current generation technologies are analyzed, and their integration (or evolution) with an ADMS technology is discussed. An ADMS technology state of the art and gap analysis is also presented. There are two technical gaps observed. The integration challenge between the component operational systems is the single largest challenge for ADMS design and deployment. Another significant challenge noted is concerning essential ADMS applications, for instance, fault location, isolation, and service restoration (FLISR), volt-var optimization (VVO), etc. There are a relatively small number of ADMS application developers as ADMS software platform is not open source. There is another critical gap and while not being technical in nature (when compared the two above) is still important to consider. The data models currently residing in utility GIS systems are either incomplete or inaccurate or both. This data is essential for planning and operations because it is typically one of the primary sources from which power system model are created. To achieve the full potential of ADMS, the ability to execute acute Power Flow solution is an important pre-requisite. These critical gaps are hindering wider Utility adoption of an ADMS technology. The development of an open architecture platform can eliminate many of these barriers and also aid seamless integration of distribution Utility legacy systems with an ADMS.

24 POWER TRANSMISSION AND DISTRIBUTION↗

Energy Storage in South Asia: Understanding the Role of Grid-Connected Energy Storage in South Asia’s Power Sector Transformation

During the last decade, the cost of energy storage technologies, primarily lithium-ion battery energy storage systems (BESS), has declined rapidly and is projected to decline further over the next decade. This study provides a first-of-its-kind assessment of cost-effective opportunities for grid-scale energy storage deployment in South Asia both in the near term and the long term, including a detailed analysis of energy storage drivers, potential barriers, and the role of energy storage in system operations. We conduct scenarios-based capacity expansion modeling to assess when, where and how much energy storage can be cost-effectively deployed in India through 2050. The analysis relies on state-of-the-art modeling approaches to uncover and compare the value streams of battery storage with different durations as well as pumped storage hydropower. We also run hourly simulations of system operations in 2030 and 2050 to understand how energy storage will be utilized by system operators to help integrate RE and reduce operating costs. For Bangladesh, Bhutan, and Nepal, we use operational simulations to explore how increasing deployment of energy storage can help optimize the use of domestic resources and cross-border electricity trade.

29 ENERGY PLANNING, POLICY, AND ECONOMY↗

SmartApps: Middle-ware for Adaptive Applications on Reconfigurable Platforms

There are several reasons why the performance of current distributed and heterogeneous systems is often disappointing. For example, the characteristics of the application may be input sensitive and evolve during execution causing dramatic changes in memory reference patterns, resource requirements, or degree of concurrency between different phases of the computation. Or, the system may change dynamically with nodes failing or appearing, some network links severed and other links established with different latencies and bandwidths. Another important reason for poor performance is the fairly compartmentalized approach to optimization: applications, compilers, operating systems and hardware configurations are designed and optimized in isolation and without the knowledge of instance specific information and needs of a running application. There is too little information flow across these boundaries and no global optimization is even attempted. For example, most operating systems services like paging, virtual-to-physical page mapping, I/O, or data layout in disks, provide little or no application customization. Similarly, the off-the-shelf hardware used by most commercial systems is optimized to give best average-case performance. To address this problem, we have proposed application-centric computing, or Smart Applications (SAS). In the SAS executable, the compiler embeds most run-time system services, and a performance-optimizing feedback loop that monitors the application's performance and adaptively reconfigures the application and the OS/system platform. At run-time, after incorporating the code's input and determining the system's resources and state, the SAS performs an *instance* specific optimization, which is more tractable than a global generic optimization between application, OS and system. The overriding philosophy of SAS is ``measure, compare, and adapt if beneficial.'' That is, the application will continually monitor its performance and the available resources to determine if, and by how much, performance could be improved if the application was restructured. Then, if the potential performance benefit outweighs the projected overhead costs, the application will restructure itself and the underlying system accordingly. The SAS framework includes performance monitoring and modeling components and mechanisms for performing the actual restructuring at various levels including: (i) algorithmic adaptation, (ii) run-time software optimization (e.g., input sensitivity analysis, etc.), (iii) tuning reconfigurable OS services (scheduling policy, page size, etc), and (iv) system configuration (e.g., selecting which, and how many, computational resources to use). SmartApps is being developed in the STAPL infrastructure. STAPL (the Standard Template Adaptive Parallel Library) is a framework for developing highly-optimizable, adaptable, and portable parallel and distributed applications. It consists of a relatively new and still evolving collection of generic parallel algorithms and distributed containers and a run-time system (RTS) through which the application and compiler interact with the OS and hardware.

97 MATHEMATICS AND COMPUTING↗

Los Angeles Air Force Base Vehicle-to-Grid Demonstration (Final Project Report)

Electrification of non-tactical vehicle fleets represents a key efficiency and energy security objective for the United States Department of Defense. To achieve electrification, the department targeted vehicle-to-grid services as a way to decrease the overall cost of operating the vehicle fleet and achieve rough parity with traditional internal combustion engine vehicle fleets. This report describes efforts to aggregate a fleet of bi-directional electric vehicles and charging stations to provide regulation up and regulation down in the California Independent System Operator ancillary services market. A 29-vehicle electric vehicle demonstration fleet, consisting of mixed purpose and duty vehicles such as sedans, pickups, vans, and medium-duty trucks, was deployed at the Los Angeles Air Force base. The fleet provided frequency regulation to the California Independent System Operator’s wholesale electricity market to determine the capability of recouping some of the additional costs of procuring electric vehicles and their supporting infrastructure. Lawrence Berkeley National Laboratory, with its partner Kisensum, LLC, developed the fleet scheduling, optimization, and control software to allow the vehicle fleet at the air force base to participate in the ancillary services markets. This report focuses on the control software and market interactions, the significant challenges faced and solutions devised to address them, and examines the potential of using the electric vehicle fleet as an energy storage resource for the base buildings, an application known as vehicle-tobuilding, in providing demand response and emergency backup power. The report discusses key findings related to providing frequency regulation to the California Independent System Operator market, electric vehicle fleet performance, compatibility of varying resource parameters of vehicle fleet aggregation, the need for automated methods for communicating hour-ahead energy bidding, challenges related to battery capacity and charge/discharge rates, and monthly settlement revenue.

32 ENERGY CONSERVATION, CONSUMPTION, AND UTILIZATI↗

A Case Study of Luminaire-Level Lighting Control: Lighting the Northwest Energy Efficiency Alliance (NEEA) Office in Portland, OR

What happens when advanced lighting and control systems are installed in the real world? Are the advantages and energy savings realized? By observing the design, installation, commissioning, and ongoing use of connected lighting systems in real-world settings, it is possible to identify the strengths, challenges, and points of human-technology interaction that may be new or unfamiliar to those responsible for implementing or maintaining the lighting system. Ultimately, understanding and experiencing each stakeholder’s interaction with the technology can allow the research team to synthesize feedback for manufacturers, improve industry understanding of the technology, and increase adoption. The Northwest Energy Efficiency Alliance (NEEA) office in Portland, OR, is a single-floor installation that puts tunable-white, interoperability, and luminaire-level advanced control capabilities to the test. Compared to simpler, “out-of-the-box” systems that minimize field-adjustable settings, the system utilized in this space allowed for granular field adjustments which required the system specifier, client, and programming agent to make additional decisions regarding system operation while the system was being programmed. This report communicates the observational findings from the installation, programming, and ongoing operation of an advanced office LLLC system.

32 ENERGY CONSERVATION, CONSUMPTION, AND UTILIZATI↗

Implications of Power Plant Idling and Cycling on Water Use Intensity

Survey data from the Energy Information Administration (EIA) was combined with data from the Environmental Protection Agency (EPA) to explore ways in which operations might impact water use intensity (both withdrawals and consumption) at thermoelectric power plants. Two disparities in cooling and power systems operations were identified here that could impact water use intensity: 1) Idling Gap—where cooling systems continue to operate when their boilers and generators are completely idled; and 2) Cycling Gap—where cooling systems operate at full capacity, while their associated boiler and generator systems cycle over a range of loads. Analysis of the EIA and EPA data indicated that cooling systems operated on average 13% more than their corresponding power system (Idling Gap), while power systems operated on average 30% below full load when the boiler was reported as operating (Cycling Gap). Regression analysis was then performed to explore whether the degree of power plant idling/cycling could be related to the physical characteristics of the plant, its environment or time of year. While results suggested that individual power plants’ operations were unique, weak trends consistently pointed to a plant’s place on the dispatch curve as influencing patterns of cooling system, boiler, and generator operation. This insight better positions us to interpret reported power plant water use data as well as improve future water use projections.

54 ENVIRONMENTAL SCIENCES↗

Wavelet Denoising of Mobile Radiation Data

The FY08 phase of this project investigated the merits of video fusion as a method for mitigating the false alarms encountered by vehicle borne detection systems in an effort to realize performance gains associated with wavelet denoising. The fusion strategy exploited the significant correlations which exist between data obtained from radiation detectors and video systems with coincident fields of view. The additional information provided by optical systems can greatly increase the capabilities of these detection systems by reducing the burden of false alarms and through the generation of actionable information. The investigation into the use of wavelet analysis techniques as a means of filtering the gross-counts signal obtained from moving radiation detectors showed promise for vehicle borne systems. However, the applicability of these techniques to man-portable systems is limited due to minimal gains in performance over the rapid feedback available to system operators under walking conditions. Furthermore, the fusion of video holds significant promise for systems operating from vehicles or systems organized into stationary arrays; however, the added complexity and hardware required by this technique renders it infeasible for man-portable systems.

07 ISOTOPE AND RADIATION SOURCES↗

A new solid state extractor pulser for the FNAL magnetron ion source

A new solid state extractor pulser has been installed on the Fermi National Accelerator Laboratory (FNAL) magnetron ion source, replacing a vacuum tube style pulser that was used for over 40 years. The required ion source extraction voltage is 35 kV for injection into the radio frequency quadrupole. At this voltage, the old pulser had a rise time of over 150 μs due to the current limit of the vacuum tube. The new solid state pulsers are capable of 50 kV, 100 A peak current pulses and have a rise time of 9 μs when installed in the operational system. This paper will discuss the pulser design and operational experience to date.

46 INSTRUMENTATION RELATED TO NUCLEAR SCIENCE AND ↗

Short-Term Load Forecasting Error Distributions and Implications for Renewable Integration Studies: Preprint

Load forecasting in the day-ahead timescale is a critical aspect of power system operations that is used in the unit commitment process. It is also an important factor in renewable energy integration studies, where the combination of load and wind or solar forecasting techniques create the net load uncertainty that must be managed by the economic dispatch process or with suitable reserves. An understanding of that load forecasting errors that may be expected in this process can lead to better decisions about the amount of reserves necessary to compensate errors. In this work, we performed a statistical analysis of the day-ahead (and two-day-ahead) load forecasting errors observed in two independent system operators for a one-year period. Comparisons were made with the normal distribution commonly assumed in power system operation simulations used for renewable power integration studies. Further analysis identified time periods when the load is more likely to be under- or overforecast.

17 WIND ENERGY↗

Transmission Operator Workflows for Real-Time Reliability Studies: A Review of Control Room Practices and Naturalistic Decision Making

This report provides an overview of real-time reliability study tools and their use by power system operators in the control room environment. After introducing some of the nuances of the control room environment and the differences in perspectives between power system engineers and operators, the roles and responsibilities of key entities involved in RTCA workflows are introduced. These are specifically the transmission system operator (TOP) and reliability coordinator (RC), which are required to run tools such as real-time contingency analysis (RTCA) as part of a real-time reliability assessment every 30 minutes, as dictated by a series of standards issued by the North American Electric Reliability Corporation (NERC). The process by which power systems operators operate the grid is discussed in terms of naturalistic decision making (NDM) and the recognition-primed decision-making (RPD) model. This cognitive model describe how experts working in high-risk, high-stress environments make safety-critical decisions under uncertainty and time pressure. For power system operators, the mental simulations involved in the traditional RPD model are supplemented by physics-based simulations using numerical tools, such as RTCA, to improve situational awareness and effectiveness of control actions. Next, a generic workflow is introduced to describe operator decision making for running RTCA tools and responding to system violations on a pre-contingent basis. The types of analysis performed and control actions chosen by power system operators are described in detail. The overall high-level workflow is then expanded in subsequent sections, with special attention given to high-voltage violations, low-voltage violations, and thermal overloads. Each type of violation is described in detail, with explanations of common causes, impacts on equipment and customers, and mitigation strategies. An additional workflow diagram is provided for each type of violation.

24 POWER TRANSMISSION AND DISTRIBUTION↗

Alliance Project: Secure Control Systems for the Energy Sector

The Alliance Project addresses Area of Interest 4: Secure Remote Access for the Energy Sector, by combining physical and cyber access under one cybersecurity access system. The Alliance Project built on the successful completion of the Lemnos and Padlock Project (DOE-Funded Project started in 2007 and 2010) and researched and developed a solution for an Ethernet Security Gateway with the functionality required to integrate the physical access control cyber system and interface with legacy and new proximity card readers used for physical access requests. This project focused on securing and enhancing the cyber system the physical access control system operates on. The team tested and demonstrated the system solution on the SEL campus. Currently the physical access cyber system is completely separate from the cyber access control cyber system. With a single system industry benefits include: (1) Single system to learn and teach employees; (2) Single system that collects and alerts on logs and events simplifying incident response plans and NERC CIP compliance; (3) Unifies trust management to a single system reducing the potential errors in privilege escalation or revocation; (4) Provides a stronger cybersecurity platform the physical access control system operates on. Today they are mostly plain text protocols and little cyber awareness; (5) Integration of physical access awareness allows the cyber system to react and adjust. In some cases, the cyber access can be enhanced with authorized physical access and other cases the cyber access can be more restricted with unauthorized physical access; and (6) Enables the utility to establish as large or as small a physical access control system as they require. One example would be when a utility shares a substation with a neighbor utility and can’t rely on the substation door for the physical access control. The Alliance technology enables them to lock equipment racks simply with no scalability issues because it stands on the cyber security infrastructure which is already highly scalable.

24 POWER TRANSMISSION AND DISTRIBUTION↗

Implementation and Operation of Power Flow Control Solutions for Transmission Systems

Power-flow controls (PFCs) technologies provide a suite of alternatives to more-efficiently direct the flow of power on the grid, improving flexibility and enabling the grid to be more responsive and resilient. PFCs can be used in many cases to mitigate overloads and consequently defer the installation of grid-expansion projects. They can also be suitable options in situations where new transmission lines cannot be built because of environmental constraints, land use, or other types of restrictions. Other uses include mitigation of loop or unintended flows, forcing of contractual or scheduled flows, reduction of congestion, and mitigation solutions during large maintenance or construction projects. While many studies have demonstrated the potential economic benefits of PFC for different types of applications, the implementation implications of using multiple PFCs for system operation and reliability have not been analyzed in detail. The lack of information and practical experience on these aspects hinders adoption of this technology. One use case would be that multiple PFCs are required to coordinate congestion management. In such cases, multiple PFCs are deployed in a meshed power system to control power flows across a wide area. The challenges are associated with PFC interaction—namely, the self and mutual power-flow sensitivity of each PFC, which must be accounted for in the calculation of the respective operating setpoints. This report analyzes implementation and operation that must be considered in evaluating transmission solutions using PFCs. The report first analyzes attributes with which PFC-based solutions should comply, based on the objective and characteristics of each particular use case. It then describes different approaches for coordinated control of multiple PFC devices for different applications, including options to avoid adverse interactions and reduce risks due to inappropriate coordination. Control and operation are illustrated through case studies performed on both generic and actual power system models. This report provides insights for transmission planners and operation engineers about the implementation of PFC-based transmission solutions; consequently, it will help them make informed decisions about the adoption of the technology.

24 POWER TRANSMISSION AND DISTRIBUTION↗

A Framework for Adaptable Operating and Runtime Systems

The emergence of new classes of HPC systems where performance improvement is enabled by Moore’s Law for technology is manifest through multi-core-based architectures including specialized GPU structures. Operating systems were originally designed for control of uniprocessor systems. By the 1980s multiprogramming, virtual memory, and network interconnection were integral services incorporated as part of most modern computers. HPC operating systems were primarily derivatives of the Unix model with Linux dominating the Top-500 list. The use of Linux for commodity clusters was first pioneered by the NASA Beowulf Project. However, the rapid increase in number of cores to achieve performance gain through technology advances has exposed the limitations of POSIX general-purpose operating systems in scaling and efficiency. This project was undertaken through the leadership of Sandia National Laboratories and in partnership of the University of New Mexico to investigate the alternative of composable lightweight kernels on scalable HPC architectures to achieve superior performance for a wide range of applications. The use of composable operating systems is intended to provide a minimalist set of services specifically required by a given application to preclude overheads and operational uncertainties (“OS noise”) that have been demonstrated to degrade efficiency and operational consistency. This project was undertaken as an exploration to investigate possible strategies and methods for composable lightweight kernel operating systems towards support for extreme scale systems.

97 MATHEMATICS AND COMPUTING↗

Baseline and Target Values for PV Forecasts: Toward Improved Solar Power Forecasting

Accurate solar power forecasting allows utilities to get the most out of the solar resources on their systems. To truly measure the improvements that any new solar forecasting methods can provide, it is important to first develop (or determine) baseline and target solar forecasting at different spatial and temporal scales. This paper aims to develop baseline and target values for solar forecasting metrics. These were informed by close collaboration with utility and independent system operator partners. The baseline values are established based on state-of-the-art numerical weather prediction models and persistence models. The target values are determined based on the reduction in the amount of reserves that must be held to accommodate the uncertainty of solar power output.

14 SOLAR ENERGY↗

Reviewing Consensus HFE Standards for NRC Use: A Case Study using the IEEE Standard for Computerized Operating Procedure Systems

The U.S. Nuclear Regulatory Commission’s (NRC’s) endorsement of consensus standards provides a cost-effective means of enhancing the staff’s ability to review state-of-the-art designs. Although the NRC endorsed consensus standards in many technical disciplines, it yet has to do so in human factors engineering (HFE). The purpose of our study was to develop a standardized methodology whereby to evaluate a consensus HFE standard to determine its appropriateness to, and adequacy for using in licensing reviews. The high-level objective of the methodology is to ensure that the guidance meets the NRC’s requirements on scientific- and engineering-rigor that they use in developing their own guidance. We propose four criteria for endorsing a consensus standard: (1) It should meet an existing need for NRC’s licensing and safety reviews; (2) it should be based on sound HFE principles; (3) it should be thoroughly peer-reviewed; and, (4) it should address human performance issues identified in the literature. Our methodology offers a means to assess these four criteria. We used it to evaluate an Institute of Electrical and Electronics Engineers’ (IEEE) draft standard on computerized operating procedure systems. We concluded that the IEEE standard generally met the established criteria, although several areas were identified that needed further clarification. Our evaluation methodology particularly was useful for identifying issues to be resolved, and for providing a basis for judging whether the staff should consider endorsing the standard. The methodology also helped recognize criteria in the proposed standard that may benefit from additional scrutiny by the staff. The evaluation methodology developed is applicable generally to reviewing other HFE standards that the NRC is considering for use or endorsement.

22 GENERAL STUDIES OF NUCLEAR REACTORS↗