Engineering Papers⌕ Search

SEARCH · Engineering Papers

Results for “Statistical Algorithms”

Search indexed NASA NTRS and DOE OSTI research on propulsion, heat transfer, battery materials and energy systems. Follow report and document links to the original sources.

Quote a phrase for an exact phrase match. Source license links do not imply unrestricted reuse.

At least 433 records · Page 24

CT reconstruction techniques for improved accuracy of lung CT airway measurement

Purpose: To determine the impact of constrained reconstruction techniques on quantitative CT (qCT) of the lung parenchyma and airways for low x-ray radiation dose. Methods: Measurement of small airways with qCT remains a challenge, especially for low x-ray dose protocols. Images of the COPDGene quality assurance phantom (CTP698, The Phantom Laboratory, Salem, NY) were obtained using a GE discovery CT750 HD scanner for helical scans at x-ray radiation dose-equivalents ranging from 1 to 4.12 mSv (12–100 mA s current–time product). Other parameters were 40 mm collimation, 0.984 pitch, 0.5 s rotation, and 0.625 mm thickness. The phantom was sandwiched between 7.5 cm thick water attenuating phantoms for a total length of 20 cm to better simulate the scatter conditions of patient scans. Image data sets were reconstructed using STANDARD (STD), DETAIL, BONE, and EDGE algorithms for filtered back projection (FBP), 100% adaptive statistical iterative reconstruction (ASIR), and Veo reconstructions. Reduced (half) display field of view (DFOV) was used to increase sampling across airway phantom structures. Inner diameter (ID), wall area percent (WA%), and wall thickness (WT) measurements of eight airway mimicking tubes in the phantom, including a 2.5 mm ID (42.6 WA%, 0.4 mm WT), 3 mm ID (49.0 WA%, 0.6 mm WT), and 6 mm ID (49.0 WA%, 1.2 mm WT) were performed with Airway Inspector (Surgical Planning Laboratory, Brigham and Women’s Hospital, Boston, MA) using the phase congruency edge detection method. The average of individual measures at five central slices of the phantom was taken to reduce measurement error. Results: WA% measures were greatly overestimated while IDs were underestimated for the smaller airways, especially for reconstructions at full DFOV (36 cm) using the STD kernel, due to poor sampling and spatial resolution (0.7 mm pixel size). Despite low radiation dose, the ID of the 6 mm ID airway was consistently measured accurately for all methods other than STD FBP. Veo reconstructions showed slight improvement over STD FBP reconstructions (4%–9% increase in accuracy). The most improved ID and WA% measures were for the smaller airways, especially for low dose scans reconstructed at half DFOV (18 cm) with the EDGE algorithm in combination with 100% ASIR to mitigate noise. Using the BONE + ASIR at half BONE technique, measures improved by a factor of 2 over STD FBP even at a quarter of the x-ray dose. Conclusions: The flexibility of ASIR in combination with higher frequency algorithms, such as BONE, provided the greatest accuracy for conventional and low x-ray dose relative to FBP. Veo provided more modest improvement in qCT measures, likely due to its compatibility only with the smoother STD kernel.

46 INSTRUMENTATION RELATED TO NUCLEAR SCIENCE AND ↗

Understanding performance variability in standard and pipelined parallel Krylov solvers

In this work, we collect data from runs of Krylov subspace methods and pipelined Krylov algorithms in an effort to understand and model the impact of machine noise and other sources of variability on performance. We find large variability of Krylov iterations between compute nodes for standard methods that is reduced in pipelined algorithms, directly supporting conjecture, as well as large variation between statistical distributions of runtimes across iterations. Based on these results, we improve upon a previously introduced nondeterministic performance model by allowing iterations to fluctuate over time. We present our data from runs of various Krylov algorithms across multiple platforms as well as our updated non-stationary model that provides good agreement with observations. We also suggest how it can be used as a predictive tool.

97 MATHEMATICS AND COMPUTING↗

Trajectory Optimization via Unsupervised Probabilistic Learning On Manifolds

This report investigates the use of unsupervised probabilistic learning techniques for the analysis of hypersonic trajectories. The algorithm first extracts the intrinsic structure in the data via a diffusion map approach. Using the diffusion coordinates on the graph of training samples, the probabilistic framework augments the original data with samples that are statistically consistent with the original set. The augmented samples are then used to construct conditional statistics that are ultimately assembled in a path-planing algorithm. In this framework the controls are determined stage by stage during the flight to adapt to changing mission objectives in real-time. A 3DOF model was employed to generate optimal hypersonic trajectories that comprise the training datasets. The diffusion map algorithm identfied that data resides on manifolds of much lower dimensionality compared to the high-dimensional state space that describes each trajectory. In addition to the path-planing worflow we also propose an algorithm that utilizes the diffusion map coordinates along the manifold to label and possibly remove outlier samples from the training data. This algorithm can be used to both identify edge cases for further analysis as well as to remove them from the training set to create a more robust set of samples to be used for the path-planing process.

42 ENGINEERING↗

Trajectory design via unsupervised probabilistic learning on optimal manifolds

Abstract This article illustrates the use of unsupervised probabilistic learning techniques for the analysis of planetary reentry trajectories. A three-degree-of-freedom model was employed to generate optimal trajectories that comprise the training datasets. The algorithm first extracts the intrinsic structure in the data via a diffusion map approach. We find that data resides on manifolds of much lower dimensionality compared to the high-dimensional state space that describes each trajectory. Using the diffusion coordinates on the graph of training samples, the probabilistic framework subsequently augments the original data with samples that are statistically consistent with the original set. The augmented samples are then used to construct conditional statistics that are ultimately assembled in a path planning algorithm. In this framework, the controls are determined stage by stage during the flight to adapt to changing mission objectives in real-time.

42 ENGINEERING↗

Noise spatial nonuniformity and the impact of statistical image reconstruction in CT myocardial perfusion imaging

Purpose: To achieve high temporal resolution in CT myocardial perfusion imaging (MPI), images are often reconstructed using filtered backprojection (FBP) algorithms from data acquired within a short-scan angular range. However, the variation in the central angle from one time frame to the next in gated short scans has been shown to create detrimental partial scan artifacts when performing quantitative MPI measurements. This study has two main purposes. (1) To demonstrate the existence of a distinct detrimental effect in short-scan FBP, i.e., the introduction of a nonuniform spatial image noise distribution; this nonuniformity can lead to unexpectedly high image noise and streaking artifacts, which may affect CT MPI quantification. (2) To demonstrate that statistical image reconstruction (SIR) algorithms can be a potential solution to address the nonuniform spatial noise distribution problem and can also lead to radiation dose reduction in the context of CT MPI. Methods: Projection datasets from a numerically simulated perfusion phantom and an in vivo animal myocardial perfusion CT scan were used in this study. In the numerical phantom, multiple realizations of Poisson noise were added to projection data at each time frame to investigate the spatial distribution of noise. Images from all datasets were reconstructed using both FBP and SIR reconstruction algorithms. To quantify the spatial distribution of noise, the mean and standard deviation were measured in several regions of interest (ROIs) and analyzed across time frames. In the in vivo study, two low-dose scans at tube currents of 25 and 50 mA were reconstructed using FBP and SIR. Quantitative perfusion metrics, namely, the normalized upslope (NUS), myocardial blood volume (MBV), and first moment transit time (FMT), were measured for two ROIs and compared to reference values obtained from a high-dose scan performed at 500 mA. Results: Images reconstructed using FBP showed a highly nonuniform spatial distribution of noise. This spatial nonuniformity led to large fluctuations in the temporal direction. In the numerical phantom study, the level of noise was shown to vary by as much as 87% within a given image, and as much as 110% between different time frames for a ROI far from isocenter. The spatially nonuniform noise pattern was shown to correlate with the source trajectory and the object structure. In contrast, images reconstructed using SIR showed a highly uniform spatial distribution of noise, leading to smaller unexpected noise fluctuations in the temporal direction when a short scan angular range was used. In the numerical phantom study, the noise varied by less than 37% within a given image, and by less than 20% between different time frames. Also, the noise standard deviation in SIR images was on average half of that of FBP images. In the in vivo studies, the deviation observed between quantitative perfusion metrics measured from low-dose scans and high-dose scans was mitigated when SIR was used instead of FBP to reconstruct images. Conclusions: (1) Images reconstructed using FBP suffered from nonuniform spatial noise levels. This nonuniformity is another manifestation of the detrimental effects caused by short-scan reconstruction in CT MPI. (2) Images reconstructed using SIR had a much lower and more uniform noise level and thus can be used as a potential solution to address the FBP nonuniformity. (3) Given the improvement in the accuracy of the perfusion metrics when using SIR, it may be desirable to use a statistical reconstruction framework to perform low-dose dynamic CT MPI.

62 RADIOLOGY AND NUCLEAR MEDICINE↗

The small-voxel tracking algorithm for simulating chemical reactions among diffusing molecules

Simulating the evolution of a chemically reacting system using the bimolecular propensity function, as is done by the stochastic simulation algorithm and its reaction-diffusion extension, entails making statistically inspired guesses as to where the reactant molecules are at any given time. Those guesses will be physically justified if the system is dilute and well-mixed in the reactant molecules. Otherwise, an accurate simulation will require the extra effort and expense of keeping track of the positions of the reactant molecules as the system evolves. One molecule-tracking algorithm that pays careful attention to the physics of molecular diffusion is the enhanced Green's function reaction dynamics (eGFRD) of Takahashi, Tănase-Nicola, and ten Wolde [Proc. Natl. Acad. Sci. U.S.A. 107, 2473 (2010)]. We introduce here a molecule-tracking algorithm that has the same theoretical underpinnings and strategic aims as eGFRD, but a different implementation procedure. Called the small-voxel tracking algorithm (SVTA), it combines the well known voxel-hopping method for simulating molecular diffusion with a novel procedure for rectifying the unphysical predictions of the diffusion equation on the small spatiotemporal scale of molecular collisions. Indications are that the SVTA might be more computationally efficient than eGFRD for the problematic class of non-dilute systems. A widely applicable, user-friendly software implementation of the SVTA has yet to be developed, but we exhibit some simple examples which show that the algorithm is computationally feasible and gives plausible results.

97 MATHEMATICS AND COMPUTING↗

SU-D-201-06: Random Walk Algorithm Seed Localization Parameters in Lung Positron Emission Tomography (PET) Images

Purpose: The objective of this study was to find the best seed localization parameters in random walk algorithm application to lung tumor delineation in Positron Emission Tomography (PET) images. Methods: PET images suffer from statistical noise and therefore tumor delineation in these images is a challenging task. Random walk algorithm, a graph based image segmentation technique, has reliable image noise robustness. Also its fast computation and fast editing characteristics make it powerful for clinical purposes. We implemented the random walk algorithm using MATLAB codes. The validation and verification of the algorithm have been done by 4D-NCAT phantom with spherical lung lesions in different diameters from 20 to 90 mm (with incremental steps of 10 mm) and different tumor to background ratios of 4:1 and 8:1. STIR (Software for Tomographic Image Reconstruction) has been applied to reconstruct the phantom PET images with different pixel sizes of 2×2×2 and 4×4×4 mm{sup 3}. For seed localization, we selected pixels with different maximum Standardized Uptake Value (SUVmax) percentages, at least (70%, 80%, 90% and 100%) SUVmax for foreground seeds and up to (20% to 55%, 5% increment) SUVmax for background seeds. Also, for investigation of algorithm performance on clinical data, 19 patients with lung tumor were studied. The resulted contours from algorithm have been compared with nuclear medicine expert manual contouring as ground truth. Results: Phantom and clinical lesion segmentation have shown that the best segmentation results obtained by selecting the pixels with at least 70% SUVmax as foreground seeds and pixels up to 30% SUVmax as background seeds respectively. The mean Dice Similarity Coefficient of 94% ± 5% (83% ± 6%) and mean Hausdorff Distance of 1 (2) pixels have been obtained for phantom (clinical) study. Conclusion: The accurate results of random walk algorithm in PET image segmentation assure its application for radiation treatment planning and diagnosis.

60 APPLIED LIFE SCIENCES↗

Stochastic solution of population balance equations for reactor networks

This work presents a sequential modular approach to solve a generic network of reactors with a population balance model using a stochastic numerical method. Full-coupling to the gas-phase is achieved through operator-splitting. The convergence of the stochastic particle algorithm in test networks is evaluated as a function of network size, recycle fraction and numerical parameters. These test cases are used to identify methods through which systematic and statistical error may be reduced, including by use of stochastic weighted algorithms. The optimal algorithm was subsequently used to solve a one-dimensional example of silicon nanoparticle synthesis using a multivariate particle model. This example demonstrated the power of stochastic methods in resolving particle structure by investigating the transient and spatial evolution of primary polydispersity, degree of sintering and TEM-style images. Highlights: •An algorithm is presented to solve reactor networks with a population balance model. •A stochastic method is used to solve the population balance equations. •The convergence and efficiency of the reported algorithms are evaluated. •The algorithm is applied to simulate silicon nanoparticle synthesis in a 1D reactor. •Particle structure is reported as a function of reactor length and time.

71 CLASSICAL AND QUANTUM MECHANICS, GENERAL PHYSIC↗

NGC 6811: AN INTERMEDIATE-AGE CLUSTER IN THE KEPLER FIELD

NGC 6811 is one of the four open clusters located in the Kepler spacecraft field of view. We obtained UBVRI photometry of the cluster on six nights (four of them photometric) with the 1.08 m Hall and 1.83 m Perkins telescopes at Lowell Observatory. The mean photometric precision ranges from better than 0.01 mag in the V, B - V, V - R, and V - I indices among stars brighter than magnitude 15 to about 0.05 mag for U - B at magnitude 18. We followed a Bayesian statistical approach using the Markov Chain Monte Carlo algorithm to determine the cluster reddening, distance, age, and iron content from a maximum-likelihood fit to stellar isochrones. Using the Yale-Yonsei isochrones, we derived E(B - V) 0.066 {+-} 0.025, (m - M){sub V} = 10.13 {+-} 0.19, age = 1.06 {+-} 0.19 Gyr, and Z = 0.012 {+-} 0.004 ([Fe/H] = -0.18); with the Padova isochrones, we found E(B - V) = 0.081 {+-} 0.015, (m - M){sub V} = 10.31 {+-} 0.11, age = 0.94 {+-} 0.08 Gyr, and Z = 0.012 {+-} 0.002 ([Fe/H] = -0.20). The uncertainties include possible errors in the photometric zero points of {+-}0.01 mag, but do not include uncertainties in the models. Taking into account the differences between the two sets of models, we find the best estimate for the cluster parameters to be E(B - V) = 0.074 {+-} 0.024, (m - M){sub V} = 10.22 {+-} 0.18, age = 1.00 {+-} 0.17 Gyr, and Z = 0.012 {+-} 0.004 ([Fe/H] = -0.19).

79 ASTRONOMY AND ASTROPHYSICS↗

Cancer risk at low doses of ionizing radiation: artificial neural networks inference from atomic bomb survivors

Cancer risk at low doses of ionizing radiation remains poorly defined because of ambiguity in the quantitative link to doses below 0.2 Sv in atomic bomb survivors in Hiroshima and Nagasaki arising from limitations in the statistical power and information available on overall radiation dose. To deal with these difficulties, a novel nonparametric statistics based on the ‘integrate-and-fire’ algorithm of artificial neural networks was developed and tested in cancer databases established by the Radiation Effects Research Foundation. The analysis revealed unique features at low doses that could not be accounted for by nominal exposure dose, including (i) the presence of a threshold that varied with organ, gender and age at exposure, and (ii) a small but significant bumping increase in cancer risk at low doses in Nagasaki that probably reflects internal exposure to 239 Pu. The threshold was distinct from the canonical definition of zero effect in that it was manifested as negative excess relative risk, or suppression of background cancer rates. Such a unique tissue response at low doses of radiation exposure has been implicated in the context of the molecular basis of radiation–environment interplay in favor of recently emerging experimental evidence on DNA double-strand break repair pathway choice and its epigenetic memory by histone marking.

59 BASIC BIOLOGICAL SCIENCES↗

Simulations and Experimental Verifications of an Algorithm for Radiation Source Mapping and Navigational Path Generation

Accurate and efficient mapping and localization of both ionizing and non-ionizing radiation sources are important across many different fields. As such, a versatile mapping and navigational path generation algorithm, which can be applied to any point source measurements that follow an inverse-square characteristic, was developed using non-linear least squares methods. Forty thousand simulations were performed on the algorithm, which located sources successfully in a 10 m × 10 m × 10 m three-dimensional space with a success rate of over 80% across different noise functions, given a proportional constant of 10 to 1,000. The algorithm was also verified experimentally with small-scale radioactive decontamination of a 70 cm × 70 cm surface and localization of a lost Wi-Fi router in a 70 m × 70 m open field. One hundred twenty-one measurements were taken from each experiment, which were then fed into the algorithm for navigation. For the radioactive 137Cs source, the estimated locations were within 7 cm × 7 cm of the answer in 79.3% of the scenarios, while the Wi-Fi router was located to within 7 m × 7 m in 57.9% of the tests. In general, the method requires much less information and data than a geographically comprehensive survey and thus shows a lot of potential for practical applications, such as lost source retrieval with unmanned aerial vehicles, small-scale decontamination, mapping undocumented Wi-Fi routers or radio towers, and radiation simulation with radio signals. Here, the different failure modes, desirable features, and potential improvements were also identified but remain as future work.

46 INSTRUMENTATION RELATED TO NUCLEAR SCIENCE AND ↗

Projection algorithm for state preparation on quantum computers

We present an efficient method to prepare states of a many-body system on quantum hardware, first isolating individual quantum numbers and then using time evolution to isolate the energy. Our method in its simplest form requires only one additional auxiliary qubit. The total time evolved for an accurate solution is proportional to the ratio of the spectrum range of the trial state to the gap to the lowest excited state, a substantial improvement over other projection algorithms, and the accuracy increases exponentially with the time evolved. Isolating the quantum numbers is efficient because of the known eigenvalues and increases the gap thus shortening the propagation time required. The success rate of the algorithm, or the probability of producing the desired state, is a simple function of measurement times and phases and is dominated by the square overlap of the original state to the desired state. We present examples from the nuclear shell model and the Heisenberg model. In conclusion, we compare this algorithm to previous algorithms for short evolution times and discuss potential further improvements.

73 NUCLEAR PHYSICS AND RADIATION PHYSICS↗

Estimation of Tropical Cyclone Intensity in the North Atlantic and Northeastern Pacific Basins Using TRMM Satellite Passive Microwave Observations

Here, a statistical passive microwave intensity estimation (PMW-IE) algorithm for estimating the intensity of tropical cyclones (TCs) in the North Atlantic and northeastern and central Pacific basins is developed and tested. The algorithm is derived from Tropical Rainfall Measuring Mission (TRMM) Microwave Imager (TMI) 85-GHz brightness temperatures and near-surface rain-rate retrievals to provide objective estimates of current maximum sustained surface winds (Vmax) and 6-h future Vmax of TCs. The full record of TRMM data (1998–2013) including 2326 TMI overpasses of 503 TCs is separated into dependent samples (1998–2010) for model development and independent samples (2011–13) for model verification. The best track intensities are used as dependent variables in a stepwise multiple-regression approach. Separately for each basin, three regression models are derived using selected 1) 85-GHz-only variables, 2) rain-rate-only variables, and 3) combined 85-GHz and rain variables. The algorithms are assessed using independent samples and those with contemporaneous aircraft-reconnaissance measurements. Rain-only and combined models perform better than the 85-GHz-only model. Lower errors are found for estimating the 6-h future Vmax than estimating the current Vmax using all three models. This implies that it is optimal to use passive-microwave-retrieved rain variables observed a few hours earlier to estimate TC intensity. The MAE (RMSE) of 6-h future Vmax is 9 (12) kt (1 kt ≈ 0.51 m s -1 ) when testing the combined models with ATL and EPA independent samples. Aircraft-reconnaissance-based independent samples yields a MAE of 9.6 kt and RMSE of 12.6 kt for estimating 6-h future Vmax.

58 GEOSCIENCES↗

FLC Nomination: Stephen R. Lee

STEM Mentorship Award: Given to an individual who may or may not be a direct employee of a government laboratory or facility in the Mid Continent Region, but has demonstrated exceptional character, mentorship, and creativity in the areas of science and math or by promoting the development of young people in grades K-12 or higher in technical career fields. Contributions must be unique and show measurable benefit to the laboratory, school system/students and must have occurred within the past three calendar years. Stephen R. Lee is the division leader of the Computer, Computational, and Statistical Sciences Division (CCS) at Los Alamos National Laboratory (LANL or the Laboratory). He holds a Bachelor of Science in Physics from New Mexico State University and a Master of Science in Physics from Kansas State University and began his 27-year career at the Laboratory in 1986. As division leader of CCS, Stephen is responsible for the management and oversight of CCS and all of its activities, as well as approximately 200 technical staff engaged in computer and computational, and statistical sciences. His experience and interests include computational algorithm development for largescale parallel computing (peta-scale and beyond), predictive simulations for nuclear weapons, simulation capabilities for non-nuclear weapons applications such as bioscience, homeland defense, nanotechnology, advanced computational platform research and development.

97 MATHEMATICS AND COMPUTING↗

Numerical Analysis of Fixed Point Algorithms in the Presence of Hardware Faults

The exponential growth of computational power of the extreme scale machines over the past few decades has led to a corresponding decrease in reliability and a sharp increase of the frequency of hardware faults. Our research focuses on the mathematical challenges presented by the silent hardware faults. i.e., faults that can perturb the result of computations in an inconspicuous way. Using the approach of selective reliability we present an analytic fault mode that can be used to study the resilience properties of a numerical algorithm. We apply our approach to the classical fixed point iteration and demonstrate that in the presence of hardware faults, the classical method fails to converge in expectation. We preset a modified resilient algorithm that detects and rejects faults resulting in error with large magnitude, while small faults are negated by the natural self-correcting properties of the algorithm. We show that our method is convergent (in first and second statistical moments) even in the presence of silent hardware faults.

algorithmic resilience↗

Detection, Classification and Estimation of Radioactive Contraband from Uncertain Low-Count Measurements

In this final report we discuss the development of the Statistical Radiation Detection System (SRaDS), the next-generation radiation detection software system capable of extracting all available physics information, photon-by-photon, employing Bayesian model-based sequential statistical processing techniques and capable of making a decision when statistically justified. It is a system of computational algorithms consisting of a simple photoelectron processor for the basic system with a combined photoelectron/downscatter processor for the advanced system. Both algorithms have been demonstrated on laboratory data and are available for integration into standard radiation detectors and acquisition systems as well as specialized embedded processing hardware for real-time operations. This report incorporates the basic research performed leading to the development of SRaDS in the form of attached publications discussing the theory, development and validation of the processor and subsequent designs for this powerful solution to the detection problem plaguing the radiation area for a long time.

46 INSTRUMENTATION RELATED TO NUCLEAR SCIENCE AND ↗