Engineering Papers⌕ Search

SEARCH · Engineering Papers

Results for “Spectral control”

Search indexed NASA NTRS and DOE OSTI research on propulsion, heat transfer, battery materials and energy systems. Follow report and document links to the original sources.

Quote a phrase for an exact phrase match. Source license links do not imply unrestricted reuse.

At least 433 records · Page 24

Infrared spectrometer for Voyager

The Voyager IR investigation is described, which uses a Michelson interferometer in the 180-2500/cm range, and a single-channel radiometer for the visible and near-IR, sharing a 50-cm diameter telescope. Emphasis is placed on the differences between the Voyager and the previous designs, including reductions in the field of view and in the noise equivalent spectral radiance of the instrument. Attention is given to the optical layout, the electronics module, power supply placement, thermal control heaters and flash heaters, data reduction, and calibration. A sample spectrum of Jupiter is also discussed.

Hanel, R.↗

Two-beam interferometer for optical constants measurements at near-millimeter wavelengths

A simple and versatile instrument for the measurement of optical constants in the near millimeter spectral region is described. Studies of quasi-optical components used in this instrument for effective beam transmission and control are reported. These studies include transmission characteristics of dielectric waveguides and performance of a variable coupler based on frustrated total internal reflection. Operation of this instrument as a two-beam interferometer for determining the index of refraction or as a device to measure transmission for determining the absorption coefficient are described. Values measured with this instrument at 245 GHz, using an optically pumped molecular laser as the source, are reported for several low-loss materials. Appropriate corrections and error estimates are discussed. The potential for improvement and increased accuracies are discussed.

Jones, C. R.↗

Radiative processes

Solar radiation and the processes that control its deposition in the Earth atmosphere are considered. The published data obtained since 1978 define a reference solar spectral irradiance for use in atmospheric chemical and dynamical studies, while long term satellite measurements are now providing information on variations in the output of the Sun over a range of time scales. As concerns absorption of solar radiation in the atmosphere, new cross section data for molecular oxygen and ozone are now available. Line-by-line calculations used to predict infrared flux divergences, both as regards assumptions made in radiative transfer calculations and in the spectroscopic parameters used as inputs are examined. Also examined are the influence of radiative processes on planetary scale wave activity, photochemical acceleration of radiative damping, and the breakdown of local thermodynamic equilibrium at mesospheric altitudes.

Frederick, J. E.↗

CW dye laser technique for simultaneous, spatially-resolved measurements of temperature, pressure, and velocity of NO in an underexpanded free jet

Gas dynamic quantities within an underexpanded free jet were measured nonintrusively using a rapid-tuning, CW ring dye laser. A nitrogen jet was seeded with 0.5 percent NO in N2, and the conditions were controlled such that a barrel shock formed. The frequency-doubled output of the dye laser was used to spectrally resolve rotational lines in the NO gamma band near 225 nm. With the rapid-tuning capability, these rotational spectra were acquired at a repetition rate of 4 kHz. Spatial resolution was afforded by monitoring the induced fluorescence via a lens and photomultiplier tube. Modeling the spectrally-resolved features with Voigt profiles permitted simultaneous measurements of NO velocity, rotational temperature, and pressure. Expansion of the jet was assumed to be isentropic, and agreement between measured and expected values was typically better than 10 percent over most of the Mach-number range encountered. At high Mach numbers, the measured rotational temperatures systematically departed from the isentropic temperature distribution. Such a measured departure could be ascribed to the onset of a non-Boltzmann distribution of NO rotational states.

Di Rosa, M. D.↗

Theory and implementation of high-order adaptive hp methods for analysis of incompressible viscous flows

An account is given of 'smart' algorithms for CFD which change in structure and performance with during flow calculations to accommodate changing properties of the solution. Such algorithms prominently include adaptive FEM methods, which are designed to adjust mesh parameters for the control of numerical error; attention is presently given to those which change the mesh size h and the local spectral order p in order to achieve high accuracies with minimal numbers of degrees of freedom. These 'hp methods' produce exponentially convergent approximations through which flow features are resolved by automatically distributing element sizes and spectral orders. This leads to calculation of the local (elementwise) error in the approximation.

Oden, J. T.↗

Tailoring Thin Film-Lacquer Coatings for Space Applications

Thin film coatings have the capability of obtaining a wide range of thermal radiative properties, but the development of thin film coatings can sometimes be difficult and costly when trying to achieve highly specular surfaces. Given any space mission's then-nal control requirements, there is often a need for a variation of solar absorptance (alpha(sub s)), emittance (epsilon) and/or highly specular surfaces. The utilization of thin film coatings is one process of choice for meeting challenging thermal control requirements because of its ability to provide a wide variety of alpha(sub s)/epsilon ratios. Thin film coatings' radiative properties can be tailored to meet specific thermal control requirements through the use of different metals and the variation of dielectric layer thickness. Surface coatings can be spectrally selective to enhance radiative coupling and decoupling. The application of lacquer to a surface can also provide suitable specularity for thin film application without the cost and difficulty associated with polishing.

Peters, Wanda C.↗

Tailoring Thin Film-Lacquer Coatings for Space Application

Thin film coatings have the capability of obtaining a wide range of thermal radiative properties, but the development of thin film coatings can sometimes be difficult and costly when trying to achieve highly specular surfaces. Given any space mission's thermal control requirements, there is often a need for a variation of solar absorptance (Alpha(s)), emittance (epsilon) and/or highly specular surfaces. The utilization of thin film coatings is one process of choice for meeting challenging thermal control requirements because of its ability to provide a wide variety of Alpha(s)/epsilon ratios. Thin film coatings' radiative properties can be tailored to meet specific thermal control requirements through the use of different metals and the variation of dielectric layer thickness. Surface coatings can be spectrally selective to enhance radiative coupling and decoupling. The application of lacquer to a surface can also provide suitable specularity for thin film application without the cost and difficulty associated with polishing.

Peters, Wanda C.↗

Emission Line Spectra from Low-Density Laboratory Plasmas

Using spectroscopic equipment optimized for laboratory astrophysics, we are performing systematic measurements of the line emission from astrophysically relevant ions in the wavelength band between 1 and 400 Angstroms important to X-ray missions such as Chandra, XMM, Astro-E, and EUVE. Obtained in a controlled laboratory setting at electron densities similar to those found in stellar coronae, the data are used to test spectral modeling codes for accuracy and completeness. Our effort includes the compilation of the iron L-shell emission lines from 6-18 Angstroms and the iron M-shell emission lines from 50-200 Angstroms. Many lines have been identified for the first time, and the fluxes from lines missing in the spectral modeling codes are assessed. Our measurements also assess the accuracy of line excitation calculations, including direct electron-impact excitation, dielectronic recombination, and resonance excitation. These measurements yield a calibration of specific diagnostic line ratios. Examples of our current measurements are given.

Beiersdorfer, P.↗

On-Orbit Calibration Assessment of NOAA-21 VIIRS Thermal Emissive Bands and Implications for JPSS-4 VIIRS

The Visible Infrared Imaging Radiometer Suite (VIIRS) instrument onboard the NOAA-21 (N21) satellite has been successfully operating for over three years collecting valuable scientific measurements. A large suite of weather forecasting models and scientific research applications are supported with the VIIRS measurements from N21 combined with those acquired from the VIIRS instrument onboard the S-NPP and NOAA-20 spacecraft. Among the 22 VIIRS spectral bands, there are seven thermal emissive bands (TEB) covering the 3.7 to 12.2 µm spectral range at two different spatial resolutions. The VIIRS TEB detectors are calibrated onboard using a blackbody at a controlled temperature and a space view for background signal measurement. In this paper, we discuss the on-orbit performance of the N21 VIIRS TEB using various parameters such as the detector gain, noise, and offset. This on-orbit assessment provides critical insights into instrument behavior and calibration performance that will inform pre-launch testing and post-launch validation strategies for the upcoming JPSS-4 VIIRS mission scheduled for launch in 2027. The methodologies and lessons learned from characterizing the N21 TEB performance will enable more efficient and comprehensive radiometric assessment of the next VIIRS instrument. Specific focus is placed on identifying performance trends and anomaly signatures observed during the N21 commissioning phase that can enhance the JPSS4 instrument checkout procedures and accelerate the transition to routine on-orbit operations. The established performance baselines and uncertainty estimates will serve as an acceptance criterion for the JPSS-4 commissioning activities, ensuring mission readiness and data continuity for operational users.

Amit Angal↗

Improved Methodology for Surface and Atmospheric Soundings, Error Estimates, and Quality Control Procedures: the AIRS Science Team Version-6 Retrieval Algorithm

The AIRS Science Team Version-6 AIRS/AMSU retrieval algorithm is now operational at the Goddard DISC. AIRS Version-6 level-2 products are generated near real-time at the Goddard DISC and all level-2 and level-3 products are available starting from September 2002. This paper describes some of the significant improvements in retrieval methodology contained in the Version-6 retrieval algorithm compared to that previously used in Version-5. In particular, the AIRS Science Team made major improvements with regard to the algorithms used to 1) derive surface skin temperature and surface spectral emissivity; 2) generate the initial state used to start the cloud clearing and retrieval procedures; and 3) derive error estimates and use them for Quality Control. Significant improvements have also been made in the generation of cloud parameters. In addition to the basic AIRS/AMSU mode, Version-6 also operates in an AIRS Only (AO) mode which produces results almost as good as those of the full AIRS/AMSU mode. This paper also demonstrates the improvements of some AIRS Version-6 and Version-6 AO products compared to those obtained using Version-5.

Quality Control↗

Controlled experiments in cosmological gravitational clustering

A systematic study is conducted of gravitational instability in 3D on the basis of power-law initial spectra with and without spectral cutoff, emphasizing nonlinear effects and measures of nonlinearity; effects due to short and long waves in the initial conditions are separated. The existence of second-general pancakes is confirmed, and it is noted that while these are inhomogeneous, they generate a visually strong signal of filamentarity. An explicit comparison of smoothed initial conditions with smoothed envelope models also reconfirms the need to smooth over a scale larger than any nonlinearity, in order to extrapolate directly by linear theory from Gaussian initial conditions.

Melott, Adrian L.↗

Characteristics of the optical radiation from Kaufman thrusters

The optical radiation from plasma discharges of electron-bombardment mercury-ion thrusters was investigated. Spectrographic measurements indicated that the discharge was composed primarily of mercury atoms and singly charged ions. Excitation spectra of doubly charged mercury ions was measured to obtain the fraction of such ions in the discharge. Accomplishments of spectroscopic measurements of a hollow cathode thruster included the identification of two diagnostic lines in the mercury spectrum and the interpretation of the spectral amplitudes in terms of a superposition of primary and Maxwellian electron distributions. Potential application of optical techniques to thruster control applications was also suggested by the measurements.

Milder, N. L.↗

Mechanism of colour discrimination by a bacterial sensory rhodopsin

A photosensitive protein resembling the visual pigments of invertebrates enables phototactic archaebacteria to distinguish color. This protein exists in two spectrally-distinct forms, one of which is a transient photoproduct of the other and each of which undergoes photochemical reactions controlling the cell's swimming behaviour. Activation of a single pigment molecule in the cell is sufficient to signal the flagellar motor. This signal-transduction mechanism makes evident a color-sensing capability inherent in the retinal/protein chromophore.

Spudich, J. L.↗

AVIRIS foreoptics, fiber optics and on-board calibrator

The foreoptics, fiber optic system and calibration source of the Airborne Visible/Infrared Imaging Spectrometer (AVIRIS) are described. The foreoptics, based on a modified Kennedy scanner, is coupled by optical fibers to the four spectrometers. The optical fibers allow convenient positioning of the spectrometers in the limited space and enable simple compensation of the scanner's thermal defocus (at the -23 C operating temp) by active control of the fiber focal plane position. A challenging requirement for the fiber optic system was the transmission to the spectral range 1.85 to 2.45 microns at .45 numerical aperture. This was solved with custom fluoride glass fibers from Verre Fluore. The onboard calibration source is also coupled to the spectrometers by the fibers and provides two radiometric levels and a reference spectrum to check the spectrometers' alignment. Results of the performance of the assembled subsystems are presented.

Chrisp, Michael P.↗

Detailed design of a Ride Quality Augmentation System for commuter aircraft

The design of a Ride Quality Augmentation System (RQAS) for commuter aircraft is documented. The RQAS is designed for a Cessna 402B, an 8 passenger prop twin representative to this class of aircraft. The purpose of the RQAS is the reduction of vertical and lateral accelerations of the aircraft due to atmospheric turbulence by the application of active control. The detailed design of the hardware (the aircraft modifications, the Ride Quality Instrumentation System (RQIS), and the required computer software) is examined. The aircraft modifications, consisting of the dedicated control surfaces and the hydraulic actuation system, were designed at Cessna Aircraft by Kansas University-Flight Research Laboratory. The instrumentation system, which consist of the sensor package, the flight computer, a Data Acquisition System, and the pilot and test engineer control panels, was designed by NASA-Langley. The overall system design and the design of the software, both for flight control algorithms and ground system checkout are detailed. The system performance is predicted from linear simulation results and from power spectral densities of the aircraft response to a Dryden gust. The results indicate that both accelerations are possible.

Suikat, Reiner↗

AVIRIS foreoptics, fiber optics and on-board calibrator

The foreoptics, fiber optic system and calibration source of the Airborne Visible/Infrared Imaging Spectrometer (AVIRIS) are described. The foreoptics, based on a modified Kennedy scanner, is coupled by optical fibers to the four spectrometers. The optical fibers allow convenient positioning of the spectrometers in the limited space and enable simple compensation of the scanner's thermal defocus (at the -23 C operating temp) by active control of the fiber focal plane position. A challenging requirement for the fiber optic system was the transmission to the spectral range 1.85 to 2.45 microns at .45 numerical aperture. This was solved with custom fluoride glass fibers from Verre Fluore. The onboard calibration source is also coupled to the spectrometers by the fibers and provides two radiometric levels and a reference spectrum to check the spectrometers' alignment. Results of the performance of the assembled subsystems are presented.

Chrisp, M. P.↗

Acousto-optic tunable filter multispectral imaging system

This paper discusses recent activities of Jet Propulsion Laboratory in the development of a new type of remote sensing multispectral imaging instruments using acousto-optic tunable filter (AOTF) as programmable bandpass filter. This remote sensor provides real-time operation; observational flexibility; measurements of spectral, spatial, and polarization information using a single instrument; and compact, solid state structure without moving parts. Two microcomputer-controlled AOTF imaging spectrometer breadboard systems were designed and built. One operates in the wavelength range of 0.48-0.76 micron and the other in the range of 1.2-2.5 micron. Experiments were performed using these two systems to observe geological and botanical objects in laboratory and outdoor environment. Results have demonstrated the feasibility of using the AOTF multispectral imaging system as a real-time versatile remote sensor with operational flexibility for future Army tactical applications.

Cheng, Li-Jen↗

Circadian Behavioral Study: LED vs Cool White Fluorescent - 0.1, 1, 10, 40, 80 lux

Currently, the light source most commonly used in animal habitat lighting is cool white fluorescent (CWF) light. It was the objective of this study to evaluate a novel LED light source for use in animal habitat lighting by comparing its effectiveness to CWF light in producing and maintaining a normal circadian entrainment. The LED and CWF lights had similar spectral power distributions. Sprague-Dawley rats (175-350 g) were kept individually in metabolic cages, under a strict lighting control: 4 days of acclimation at 12:12 LD, 14 days of 12:12 LD, 14 days of 24:0 LD (free-run), and finally 12:12 LD. Food and water were provided ad libitum. Three behavioral parameters were monitored continuously: gross locomotor activity, drinking, and feeding. Combined mean free run periods (tau) were (mean +/- SEM): 24.6 +/- 0.1 and 24.7 +/- 0.2 at 0.1 lux, 25.5 +/- 0.1 and 25.7 +/- 0.1 at 1.0 lux, 25.3 +/- 0.2 and 25.4 +/- 0.2 at 10 lux, 25.8 +/- 0.1 and 25.9 +/- 0.1 at 40 lux, and 25.9 +/- 0.1 and 25.9 +/- 0.1 at 80 lux, CWF and LED respectively. ANOVA found a significant effect (p < 0.05) due to light level, but no difference in tau between rats exposed to constant CWF light and rats exposed to constant LED light. This study has shown that LED light can produce the same entrainment pattern as a conventional CWT light at similar intensities (0.1, 1, 10, 40, and 80 lux). LED light sources may be a suitable replacement for conventional light sources used in animal habitat lighting while providing many mechanical and economical advantages.

Holley, Daniel C.↗