Engineering Papers⌕ Search

SEARCH · Engineering Papers

Results for “Spares”

Search indexed NASA NTRS and DOE OSTI research on propulsion, heat transfer, battery materials and energy systems. Follow report and document links to the original sources.

Quote a phrase for an exact phrase match. Source license links do not imply unrestricted reuse.

At least 433 records · Page 24

Feasibility of Helical Tomotherapy in Stereotactic Body Radiation Therapy for Centrally Located Early Stage Non-Small-Cell Lung Cancer or Lung Metastases

Purpose: To investigate the ability of helical tomotherapy (HT) to spare critical organs immediately adjacent to the tumor target in stereotactic body radiation therapy (SBRT) for centrally located lung lesions. Methods and Materials: HT SBRT plans for 10 patients with centrally located lesions or lesions immediately adjacent to a critical structure were generated. A total of 70 Gy in 10 fractions was prescribed to the planning target volume (PTV) to satisfy a target volume coverage of {>=}95% PTV receiving 70 Gy and an established set of dose constraints for the organs at risk (OARs). Quality assurance (QA) of the HT plans was performed with both ion chamber and film measurements. Results: The PTV coverage criteria was met with 95% of the PTV receiving 70.68 {+-} 0.33 Gy for all cases even though the OARs immediately adjacent to the PTV ranged from 0.38 to 0.85 cm away. The mean lung dose (MLD), and V{sub 20} were 7.15 {+-} 1.44 Gy, and 11.93 {+-} 3.24 % for the total lung, respectively. The dose parameters of MLD, V{sub 5}, V{sub 10}, and V{sub 20} for the contralateral lung were significantly lower than those for the ipsilateral lung (p < 0.05). An average dose fall off from the PTV periphery to the edge of the immediately adjacent OAR was 47.6% over an average distance of 4.87 mm. Comparison of calculated and measured doses with the ion chamber showed an average of 1.85% point dose error, whereas an average mean gamma and the area with a gamma larger than 1 of 0.20 and 0.94% were observed, respectively. Conclusion: HT allows the sparing of critical structures immediately adjacent to the tumor target, thus making SBRT for these centrally located lesions feasible.

62 RADIOLOGY AND NUCLEAR MEDICINE↗

Chemo-IMRT of Oropharyngeal Cancer Aiming to Reduce Dysphagia: Swallowing Organs Late Complication Probabilities and Dosimetric Correlates

Purpose: Assess dosimetric correlates of long-term dysphagia after chemo-intensity-modulated radiotherapy (IMRT) of oropharyngeal cancer (OPC) sparing parts of the swallowing organs. Patients and Methods: Prospective longitudinal study: weekly chemotherapy concurrent with IMRT for Stages III/IV OPC, aiming to reduce dysphagia by sparing noninvolved parts of swallowing-related organs: pharyngeal constrictors (PC), glottic and supraglottic larynx (GSL), and esophagus, as well as oral cavity and major salivary glands. Dysphagia outcomes included patient-reported Swallowing and Eating Domain scores, Observer-based (CTCAEv.2) dysphagia, and videofluoroscopy (VF), before and periodically after therapy through 2 years. Relationships between dosimetric factors and worsening (from baseline) of dysphagia through 2 years were assessed by linear mixed-effects model. Results: Seventy-three patients participated. Observer-based dysphagia was not modeled because at >6 months there were only four Grade {>=}2 cases (one of whom was feeding-tube dependent). PC, GSL, and esophagus mean doses, as well as their partial volume doses (V{sub D}s), were each significantly correlated with all dysphagia outcomes. However, the V{sub D}s for each organ intercorrelated and also highly correlated with the mean doses, leaving only mean doses significant. Mean doses to each of the parts of the PCs (superior, middle, and inferior) were also significantly correlated with all dysphagia measures, with superior PCs demonstrating highest correlations. For VF-based strictures, most significant predictor was esophageal mean doses (48{+-}17 Gy in patients with, vs 27{+-}12 in patients without strictures, p = 0.004). Normal tissue complication probabilities (NTCPs) increased moderately with mean doses without any threshold. For increased VF-based aspirations or worsened VF summary scores, toxic doses (TDs){sub 50} and TD{sub 25} were 63 Gy and 56 Gy for PC, and 56 Gy and 39 Gy for GSL, respectively. For both PC and GSL, patient-reported swallowing TDs were substantially higher than VF-based TDs. Conclusions: Swallowing organs mean doses correlated significantly with long-term worsening of swallowing. Different methods assessing dysphagia resulted in different NTCPs, and none demonstrated a threshold.

62 RADIOLOGY AND NUCLEAR MEDICINE↗

Treatment Trends and Outcomes of Small-Cell Carcinoma of the Bladder

Purpose: Treatment for small-cell carcinoma of the bladder is largely guided by case reports, retrospective reviews, and small prospective trials. This study aimed to study outcomes using a large population-based database. Methods: The Surveillance, Epidemiology, and End Results-Medicare database (1991-2005) was used to analyze how different treatment combinations of specific bladder surgeries, chemotherapy, and radiation affected patient outcomes. Trends in the use of these combinations over time were also analyzed. Results: A total of 533 patients were retrieved from the database. A bladder-sparing approach involving transurethral resection of the bladder tumor (TURBT) combined with chemotherapy and radiation yielded no significant difference in overall survival compared with patients undergoing at least a cystectomy (of whom over 90% received radical cystectomy) with chemotherapy (p > 0.05). The analysis of treatment trends indicated that these two general strategies for cure combined to account for fewer than 20% of patients. A majority of patients (54%) received TURBT as their only surgical treatment, and a subset analysis of these patients indicated that chemotherapy played a role in all stages of disease (p < 0.05) whereas radiation improved overall survival in regional-stage disease (p < 0.05). Conclusion: Relatively few patients with small-cell carcinoma of the bladder receive potentially curative therapies. Chemotherapy should be a major component of treatment. Cystectomy and bladder-sparing approaches represent two viable strategies and deserve further investigation to identify the patients who may benefit from organ preservation or not. In addition, the role of radiation in regional-stage disease should be investigated further, because it positively affects survival after TURBT.

62 RADIOLOGY AND NUCLEAR MEDICINE↗

Improvement of Prostate Treatment by Anterior Proton Fields

Purpose: We performed a treatment planning study to demonstrate the potential dosimetric benefits of anterior-oriented fields for prostate irradiation by proton beam. A novel in vivo beam range control method shows millimeter accuracy, suggesting that such fields could be safely used to spare the rectum given the sharp distal penumbra of protons. Methods and Materials: Ten prostate patients treated with water-filled endorectal balloon were selected. Bilateral fields were planned following the conventional treatment protocol. Three anterior-oriented fields (0, +30, -30 Degree-Sign ) were planned, with the range compensators manually adjusted to improve rectal sparing. Dose distributions to the clinical target volume, rectum, anterior rectal wall (ARW), bladder, bladder wall (BW), and femoral heads were compared for: A) equally weighted bilateral fields, B) a single straight anterior field, and C) two equally weighted anterior-oblique fields. Results: The anterior-oriented fields required much less beam energy, {approx}10 cm water equivalent path length less than lateral fields. For ARW, the V{sub 95%} for Plans A, B, and C were 39%, 8%, and 6%, respectively; the corresponding V{sub 80%} were 59%, 27%, and 26%, respectively (p = 0.002 when Plan A was compared with B or C). Plan B irradiated a larger volume of BW than did Plan A by 3% at V{sub 95%}, 11% at V{sub 80%}, and 16% at V{sub 50%} (p = 0.002), whereas Plan C differs little from Plan A for BW at these dose levels. The femoral heads received {approx}40% of the prescription dose in Plan A, but negligible dose in Plans B and C. Conclusions: Compared to lateral fields, anterior-oriented fields can significantly reduce dose to the ARW, particularly at high dose levels. These fields alone, or in combination with lateral fields, allow for the possibility of either reducing treatment toxicity at current prescription doses or further dose escalation in the treatment of prostate cancer.

62 RADIOLOGY AND NUCLEAR MEDICINE↗

Dosimetric Study of Current Treatment Options for Radiotherapy in Retinoblastoma

Purpose: To determine the best treatment technique for patients with retinoblastoma requiring radiotherapy to the whole eye. Methods and Materials: Treatment plans for 3 patients with retinoblastoma were developed using 10 radiotherapy techniques including electron beams, photon beam wedge pair (WP), photon beam three-dimensional conformal radiotherapy (3D-CRT), fixed gantry intensity-modulated radiotherapy (IMRT), photon volumetric arc therapy (VMAT), fractionated stereotactic radiotherapy, and helical tomotherapy (HT). Dose-volume analyses were carried out for each technique. Results: All techniques provided similar target coverage; conformity was highest for VMAT, nine-field (9F) IMRT, and HT (conformity index [CI] = 1.3) and lowest for the WP and two electron techniques (CI = 1.8). The electron techniques had the highest planning target volume dose gradient (131% of maximum dose received [D{sub max}]), and the CRT techniques had the lowest (103% D{sub max}) gradient. The volume receiving at least 20 Gy (V{sub 20Gy}) for the ipsilateral bony orbit was lowest for the VMAT and HT techniques (56%) and highest for the CRT techniques (90%). Generally, the electron beam techniques were superior in terms of brain sparing and delivered approximately one-third of the integral dose of the photon techniques. Conclusions: Inverse planned image-guided radiotherapy delivered using HT or VMAT gives better conformity index, improved orbital bone and brain sparing, and a lower integral dose than other techniques.

62 RADIOLOGY AND NUCLEAR MEDICINE↗

Individualized Nonadaptive and Online-Adaptive Intensity-Modulated Radiotherapy Treatment Strategies for Cervical Cancer Patients Based on Pretreatment Acquired Variable Bladder Filling Computed Tomography Scans

Purpose: To design and evaluate individualized nonadaptive and online-adaptive strategies based on a pretreatment established motion model for the highly deformable target volume in cervical cancer patients. Methods and Materials: For 14 patients, nine to ten variable bladder filling computed tomography (CT) scans were acquired at pretreatment and after 40 Gy. Individualized model-based internal target volumes (mbITVs) accounting for the cervix and uterus motion due to bladder volume changes were generated by using a motion-model constructed from two pretreatment CT scans (full and empty bladder). Two individualized strategies were designed: a nonadaptive strategy, using an mbITV accounting for the full-range of bladder volume changes throughout the treatment; and an online-adaptive strategy, using mbITVs of bladder volume subranges to construct a library of plans. The latter adapts the treatment online by selecting the plan-of-the-day from the library based on the measured bladder volume. The individualized strategies were evaluated by the seven to eight CT scans not used for mbITVs construction, and compared with a population-based approach. Geometric uniform margins around planning cervix-uterus and mbITVs were determined to ensure adequate coverage. For each strategy, the percentage of the cervix-uterus, bladder, and rectum volumes inside the planning target volume (PTV), and the clinical target volume (CTV)-to-PTV volume (volume difference between PTV and CTV) were calculated. Results: The margin for the population-based approach was 38 mm and for the individualized strategies was 7 to 10 mm. Compared with the population-based approach, the individualized nonadaptive strategy decreased the CTV-to-PTV volume by 48% {+-} 6% and the percentage of bladder and rectum inside the PTV by 5% to 45% and 26% to 74% (p < 0.001), respectively. Replacing the individualized nonadaptive strategy by an online-adaptive, two-plan library further decreased the percentage of bladder and rectum inside the PTV (0% to 10% and -1% to 9%; p < 0.004) and the CTV-to-PTV volume (4-96 ml). Conclusions: Compared with population-based margins, an individualized PTV results in better organ-at-risk sparing. Online-adaptive radiotherapy further improves organ-at-risk sparing.

62 RADIOLOGY AND NUCLEAR MEDICINE↗

Hippocampal Dosimetry Predicts Neurocognitive Function Impairment After Fractionated Stereotactic Radiotherapy for Benign or Low-Grade Adult Brain Tumors

Purpose: To prospectively evaluate the association between hippocampal dose and long-term neurocognitive function (NCF) impairment for benign or low-grade adult brain tumors treated with fractionated stereotactic radiotherapy (FSRT). Methods and Materials: Adult patients with benign or low-grade adult brain tumors were treated with FSRT per institutional practice. No attempt was made to spare the hippocampus. NCF testing was conducted at baseline and 18 months follow-up, on a prospective clinical trial. Regression-based standardized z scores were calculated by using similar healthy control individuals evaluated at the same test-retest interval. NCF impairment was defined as a z score {<=}-1.5. After delineation of the bilateral hippocampi according to the Radiation Therapy Oncology Group contouring atlas, dose-volume histograms were generated for the left and right hippocampi and for the composite pair. Biologically equivalent doses in 2-Gy fractions (EQD{sub 2}) assuming an {alpha}/{beta} ratio of 2 Gy were computed. Fisher's exact test and binary logistic regression were used for univariate and multivariate analyses, respectively. Dose-response data were fit to a nonlinear model. Results: Of 29 patients enrolled in this trial, 18 completed both baseline and 18-month NCF testing. An EQD{sub 2} to 40% of the bilateral hippocampi >7.3 Gy was associated with impairment in Wechsler Memory Scale-III Word List (WMS-WL) delayed recall (odds ratio [OR] 19.3; p = 0.043). The association between WMS-WL delayed recall and EQD{sub 2} to 100% of the bilateral hippocampi >0.0 Gy trended to significance (OR 14.8; p = 0.068). Conclusion: EQD{sub 2} to 40% of the bilateral hippocampi greater than 7.3 Gy is associated with long-term impairment in list-learning delayed recall after FSRT for benign or low-grade adult brain tumors. Given that modern intensity-modulated radiotherapy techniques can reduce the dose to the bilateral hippocampi below this dosimetric threshold, patients should be enrolled in ongoing prospective trials of hippocampal sparing during cranial irradiation to confirm these preliminary results.

62 RADIOLOGY AND NUCLEAR MEDICINE↗

Volumetric Modulation Arc Radiotherapy With Flattening Filter-Free Beams Compared With Static Gantry IMRT and 3D Conformal Radiotherapy for Advanced Esophageal Cancer: A Feasibility Study

Purpose: A feasibility study was performed to evaluate RapidArc (RA), and the potential benefit of flattening filter-free beams, on advanced esophageal cancer against intensity-modulated radiotherapy (IMRT) and three-dimensional conformal radiotherapy (3D-CRT). Methods and Materials: The plans for 3D-CRT and IMRT with three to seven and five to seven fixed beams were compared against double-modulated arcs with avoidance sectors to spare the lungs for 10 patients. All plans were optimized for 6-MV photon beams. The RA plans were studied for conventional and flattening filter-free (FFF) beams. The objectives for the planning target volume were the volume receiving {>=}95% or at most 107% of the prescribed dose of <1% with a dose prescription of 59.4 Gy. For the organs at risk, the lung volume (minus the planning target volume) receiving {>=}5 Gy was <60%, that receiving 20 Gy was <20%-30%, and the mean lung dose was <15.0 Gy. The heart volume receiving 45 Gy was <20%, volume receiving 30 Gy was <50%. The spinal dose received by 1% was <45 Gy. The technical delivery parameters for RA were assessed to compare the normal and FFF beam characteristics. Results: RA and IMRT provided equivalent coverage and homogeneity, slightly superior to 3D-CRT. The conformity index was 1.2 {+-} 0.1 for RA and IMRT and 1.5 {+-} 0.2 for 3D-CRT. The mean lung dose was 12.2 {+-} 4.5 for IMRT, 11.3 {+-} 4.6 for RA, and 10.8 {+-} 4.4 for RA with FFF beams, 18.2 {+-} 8.5 for 3D-CRT. The percentage of volume receiving {>=}20 Gy ranged from 23.6% {+-} 9.1% to 21.1% {+-} 9.7% for IMRT and RA (FFF beams) and 39.2% {+-} 17.0% for 3D-CRT. The heart and spine objectives were met by all techniques. The monitor units for IMRT and RA were 457 {+-} 139, 322 {+-} 20, and 387 {+-} 40, respectively. RA with FFF beams showed, compared with RA with normal beams, a {approx}20% increase in monitor units per Gray, a 90% increase in the average dose rate, and 20% reduction in beam on time (owing to different gantry speeds). Conclusion: RA demonstrated, compared with conventional IMRT, a similar target coverage and some better dose sparing to the organs at risk; the advantage against conventional 3D-CRT was more evident. RA with FFF beams resulted in minor improvements in plan quality but with the potential for additional useful reduction in the treatment time.

62 RADIOLOGY AND NUCLEAR MEDICINE↗

Kilovoltage Rotational External Beam Radiotherapy on a Breast Computed Tomography Platform: A Feasibility Study

Purpose: To demonstrate the feasibility of a dedicated breast computed tomography (bCT) platform to deliver rotational kilovoltage (kV) external beam radiotherapy (RT) for partial breast irradiation, whole breast irradiation, and dose painting. Methods and Materials: Rotational kV-external beam RT using the geometry of a prototype bCT platform was evaluated using a Monte Carlo simulator. A point source emitting 178 keV photons (approximating a 320-kVp spectrum with 4-mm copper filtration) was rotated around a 14-cm voxelized polyethylene disk (0.1 cm tall) or cylinder (9 cm tall) to simulate primary and primary plus scattered photon interactions, respectively. Simulations were also performed using voxelized bCT patient images. Beam collimation was varied in the x-y plane (1-14 cm) and in the z-direction (0.1-10 cm). Dose painting for multiple foci, line, and ring distributions was demonstrated using multiple rotations with varying beam collimation. Simulations using the scanner's native hardware (120 kVp filtered by 0.2-mm copper) were validated experimentally. Results: As the x-y collimator was narrowed, the two-dimensional dose profiles shifted from a cupped profile with a high edge dose to an increasingly peaked central dose distribution with a sharp dose falloff. Using a 1-cm beam, the cylinder edge dose was <7% of the dose deposition at the cylinder center. Simulations using 120-kVp X-rays showed distributions similar to the experimental measurements. A homogeneous dose distribution (<2.5% dose fluctuation) with a 20% decrease in dose deposition at the cylinder edge (i.e., skin sparing) was demonstrated by weighted summation of four dose profiles using different collimation widths. Simulations using patient bCT images demonstrated the potential for treatment planning and image-guided RT. Conclusions: Rotational kV-external beam RT for partial breast irradiation, dose painting, and whole breast irradiation with skin sparing is feasible on a bCT platform with the potential for high-resolution image-guided RT.

62 RADIOLOGY AND NUCLEAR MEDICINE↗

Postoperative Radiotherapy for Prostate Cancer: A Comparison of Four Consensus Guidelines and Dosimetric Evaluation of 3D-CRT Versus Tomotherapy IMRT

Purpose: Despite the benefits of adjuvant radiotherapy after radical prostatectomy, approximately one-half of patients relapse. Four consensus guidelines have been published (European Organization for Research and Treatment of Cancer, Faculty of Radiation Oncology Genito-Urinary Group, Princess Margaret Hospital, Radiation Therapy Oncology Group) with the aim of standardizing the clinical target volume (CTV) delineation and improve outcomes. To date, no attempt has been made to compare these guidelines in terms of treatment volumes or organ at risk (OAR) irradiation. The extent to which the guideline-derived plans meet the dosimetric constraints of present trials or of the Quantitative Analysis of Normal Tissue Effects in the Clinic (QUANTEC) trial is also unknown. Our study also explored the dosimetric benefits of intensity-modulated radiotherapy (IMRT). Methods and Materials: A total of 20 patients treated with postoperative RT were included. The three-dimensional conformal radiotherapy (3D-CRT) plans were applied to cover the guideline-generated planning target volumes (66 Gy in 33 fractions). Dose-volume histograms (DVHs) were analyzed for CTV/planning target volume coverage and to evaluate OAR irradiation. The OAR DVHs were compared with the constraints proposed in the QUANTEC and Radiotherapy and Androgen Deprivation In Combination After Local Surgery (RADICALS) trials. 3D-CRT plans were compared with the tomotherapy plans for the Radiation Therapy Oncology Group planning target volume to evaluate the advantages of IMRT. Results: The CTV differed significantly between guidelines (p < 0.001). The European Organization for Research and Treatment of Cancer-CTVs were significantly smaller than the other CTVs (p < 0.001). Differences in prostate bed coverage superiorly accounted for the major volumetric differences between the guidelines. Using 3D-CRT, the DVHs rarely met the QUANTEC or RADICALS rectal constraints, independent of the guideline used. The RADICALS bladder constraints were met most often by the European Organization for Research and Treatment of Cancer consensus guideline (14 of 20). The tomotherapy IMRT plans resulted in significant OAR sparing compared with the 3D-CRT plans; however, the RADICALS and QUANTEC criteria were still missed in a large percentage of cases. Conclusion: Treatment volumes using the current consensus guidelines differ significantly. For the four CTV guidelines, the rectal and bladder DVH constraints proposed in the QUANTEC and RADICALS trials are rarely met with 3D-CRT. IMRT results in significant OAR sparing; however, the RADICALS dose constraints are still missed for a large percentage of cases. The rectal and bladder constraints of RADICALS should be modified to avoid a reduction in the CTVs.

62 RADIOLOGY AND NUCLEAR MEDICINE↗

Prospective Assessment of Optimal Individual Position (Prone Versus Supine) for Breast Radiotherapy: Volumetric and Dosimetric Correlations in 100 Patients

Purpose: Damage to heart and lung from breast radiotherapy is associated with increased cardiovascular mortality and lung cancer development. We conducted a prospective study to evaluate which position is best to spare lung and heart from radiotherapy exposure. Methods and Materials: One hundred consecutive Stage 0-IIA breast cancer patients consented to participate in a research trial that required two computed tomography simulation scans for planning both supine and prone positions. The optimal position was defined as that which best covered the contoured breast and tumor bed while it minimized critical organ irradiation, as quantified by the in-field heart and lung volume. The trial was designed to plan the first 100 patients in each position to study correlations between in-field volumes of organs at risk and dose. Results: Fifty-three left and 47 right breast cancer patients were consecutively accrued to the trial. In all patients, the prone position was optimal for sparing lung volume compared to the supine setup (mean lung volume reduction was 93.5 cc for right and 103.6 cc for left breast cancer patients). In 46/53 (87%) left breast cancer patients best treated prone, in-field heart volume was reduced by a mean of 12 cc and by 1.8 cc for the other 7/53 (13%) patients best treated supine. As predicted, supine-prone differences in in-field volume and mean dose of heart and lung were highly correlated (Spearman's correlation coefficient for left breast cancer patients was 0.90 for heart and 0.94 for lung and 0.92 for right breast cancer patients for lung). Conclusions: Prone setup reduced the amount of irradiated lung in all patients and reduced the amount of heart volume irradiated in 87% of left breast cancer patients. In-field organ volume is a valid surrogate for predicting dose; the trial continued to the planned target of 400.

62 RADIOLOGY AND NUCLEAR MEDICINE↗

A Dosimetric Comparison of Tomotherapy and Volumetric Modulated Arc Therapy in the Treatment of High-Risk Prostate Cancer With Pelvic Nodal Radiation Therapy

Purpose: To compare the dosimetric results of volumetric modulated arc therapy (VMAT) and helical tomotherapy (HT) in the treatment of high-risk prostate cancer with pelvic nodal radiation therapy. Methods and Materials: Plans were generated for 10 consecutive patients treated for high-risk prostate cancer with prophylactic whole pelvic radiation therapy (WPRT) using VMAT and HT. After WPRT, a sequential boost was delivered to the prostate. Plan quality was assessed according to the criteria of the International Commission on Radiation Units and Measurements 83 report: the near-minimal (D98%), near-maximal (D2%), and median (D50%) doses; the homogeneity index (HI); and the Dice similarity coefficient (DSC). Beam-on time, integral dose, and several organs at risk (OAR) dosimetric indexes were also compared. Results: For WPRT, HT was able to provide a higher D98% than VMAT (44.3 {+-} 0.3 Gy and 43.9 {+-} 0.5 Gy, respectively; P=.032) and a lower D2% than VMAT (47.3 {+-} 0.3 Gy and 49.1 {+-} 0.7 Gy, respectively; P=.005), leading to a better HI. The DSC was better for WPRT with HT (0.89 {+-} 0.009) than with VMAT (0.80 {+-} 0.02; P=.002). The dosimetric indexes for the prostate boost did not differ significantly. VMAT provided better rectum wall sparing at higher doses (V70, V75, D2%). Conversely, HT provided better bladder wall sparing (V50, V60, V70), except at lower doses (V20). The beam-on times for WPRT and prostate boost were shorter with VMAT than with HT (3.1 {+-} 0.1 vs 7.4 {+-} 0.6 min, respectively; P=.002, and 1.5 {+-} 0.05 vs 3.7 {+-} 0.3 min, respectively; P=.002). The integral dose was slightly lower for VMAT. Conclusion: VMAT and HT provided very similar and highly conformal plans that complied well with OAR dose-volume constraints. Although some dosimetric differences were statistically significant, they remained small. HT provided a more homogeneous dose distribution, whereas VMAT enabled a shorter delivery time.

62 RADIOLOGY AND NUCLEAR MEDICINE↗

Toward Fully Automated Multicriterial Plan Generation: A Prospective Clinical Study

Purpose: To prospectively compare plans generated with iCycle, an in-house-developed algorithm for fully automated multicriterial intensity modulated radiation therapy (IMRT) beam profile and beam orientation optimization, with plans manually generated by dosimetrists using the clinical treatment planning system. Methods and Materials: For 20 randomly selected head-and-neck cancer patients with various tumor locations (of whom 13 received sequential boost treatments), we offered the treating physician the choice between an automatically generated iCycle plan and a manually optimized plan using standard clinical procedures. Although iCycle used a fixed “wish list” with hard constraints and prioritized objectives, the dosimetrists manually selected the beam configuration and fine tuned the constraints and objectives for each IMRT plan. Dosimetrists were not informed in advance whether a competing iCycle plan was made. The 2 plans were simultaneously presented to the physician, who then selected the plan to be used for treatment. For the patient group, differences in planning target volume coverage and sparing of critical tissues were quantified. Results: In 32 of 33 plan comparisons, the physician selected the iCycle plan for treatment. This highly consistent preference for the automatically generated plans was mainly caused by the improved sparing for the large majority of critical structures. With iCycle, the normal tissue complication probabilities for the parotid and submandibular glands were reduced by 2.4% ± 4.9% (maximum, 18.5%, P=.001) and 6.5% ± 8.3% (maximum, 27%, P=.005), respectively. The reduction in the mean oral cavity dose was 2.8 ± 2.8 Gy (maximum, 8.1 Gy, P=.005). For the swallowing muscles, the esophagus and larynx, the mean dose reduction was 3.3 ± 1.1 Gy (maximum, 9.2 Gy, P<.001). For 15 of the 20 patients, target coverage was also improved. Conclusions: In 97% of cases, automatically generated plans were selected for treatment because of the superior quality. Apart from the improved plan quality, automatic plan generation is economically attractive because of the reduced workload.

62 RADIOLOGY AND NUCLEAR MEDICINE↗

Toxicities Affecting Quality of Life After Chemo-IMRT of Oropharyngeal Cancer: Prospective Study of Patient-Reported, Observer-Rated, and Objective Outcomes

Purpose: To test the hypothesis that intensity modulated radiation therapy (IMRT) aiming to spare the salivary glands and swallowing structures would reduce or eliminate the effects of xerostomia and dysphagia on quality of life (QOL). Methods and Materials: In this prospective, longitudinal study, 72 patients with stage III-IV oropharyngeal cancer were treated uniformly with definitive chemo-IMRT sparing the salivary glands and swallowing structures. Overall QOL was assessed by summary scores of the Head Neck QOL (HNQOL) and University of Washington QOL (UWQOL) questionnaires, as well as the HNQOL “Overall Bother” question. Quality of life, observer-rated toxicities (Common Toxicity Criteria Adverse Effects scale, version 2), and objective evaluations (videofluoroscopy assessing dysphagia and saliva flow rates assessing xerostomia) were recorded from before therapy through 2 years after therapy. Correlations between toxicities/objective evaluations and overall QOL were assessed using longitudinal repeated measures of analysis and Pearson correlations. Results: All observer-rated toxicities and QOL scores worsened 1-3 months after therapy and improved through 12 months, with minor further improvements through 24 months. At 12 months, dysphagia grades 0-1, 2, and 3, were observed in 95%, 4%, and 1% of patients, respectively. Using all posttherapy observations, observer-rated dysphagia was highly correlated with all overall QOL measures (P<.0001), whereas xerostomia and mucosal and voice toxicities were significantly correlated with some, but not all, overall QOL measures, with lower correlation coefficients than dysphagia. Late overall QOL (≥6 or ≥12 months after therapy) was primarily associated with observer-rated dysphagia, and to a lesser extent with xerostomia. Videofluoroscopy scores, but not salivary flows, were significantly correlated with some of the overall QOL measures. Conclusion: After chemo-IMRT, although late dysphagia was on average mild, it was still the major correlate of QOL. Further efforts to reduce swallowing dysfunction are likely to yield additional gains in QOL.

62 RADIOLOGY AND NUCLEAR MEDICINE↗

Longitudinal Investigation of Adaptive Functioning Following Conformal Irradiation for Pediatric Craniopharyngioma and Low-Grade Glioma

Purpose: Children treated for brain tumors with conformal radiation therapy experience preserved cognitive outcomes. Early evidence suggests that adaptive functions or independent-living skills may be spared. This longitudinal investigation prospectively examined intellectual and adaptive functioning during the first 5 years following irradiation for childhood craniopharyngioma and low-grade glioma (LGG). The effect of visual impairment on adaptive outcomes was investigated. Methods and Materials: Children with craniopharyngioma (n=62) and LGG (n=77) were treated using conformal or intensity modulated radiation therapy. The median age was 8.05 years (3.21-17.64 years) and 8.09 years (2.20-19.27 years), respectively. Serial cognitive evaluations including measures of intelligence quotient (IQ) and the Vineland Adaptive Behavior Scales (VABS) were conducted at preirradiation baseline, 6 months after treatment, and annually through 5 years. Five hundred eighty-eight evaluations were completed during the follow-up period. Results: Baseline assessment revealed no deficits in IQ and VABS indices for children with craniopharyngioma, with significant (P<.05) longitudinal decline in VABS Communication and Socialization indices. Clinical factors associated with more rapid decline included females and preirradiation chemotherapy (interferon). The only change in VABS Daily Living Skills correlated with IQ change (r=0.34; P=.01) in children with craniopharyngioma. Children with LGG performed below population norms (P<.05) at baseline on VABS Communication, Daily Living Indices, and the Adaptive Behavior Composite, with significant (P<.05) longitudinal decline limited to VABS Communication. Older age at irradiation was a protective factor against longitudinal decline. Severe visual impairment did not independently correlate with poorer adaptive outcomes for either tumor group. Conclusions: There was relative sparing of postirradiation functional outcomes over time in this sample. Baseline differences in functional abilities before the initiation of irradiation suggested that other factors influence functional outcomes above and beyond the effects of irradiation.

62 RADIOLOGY AND NUCLEAR MEDICINE↗

Protons in Head-and-Neck Cancer: Bridging the Gap of Evidence

Purpose: To use Normal Tissue Complication Probability (NTCP) models and comparative planning studies to explore the (cost-)effectiveness of swallowing sparing intensity modulated proton radiotherapy (IMPT) compared with swallowing sparing intensity modulated radiotherapy with photons (IMRT) in head and neck cancer (HNC). Methods and Materials: A Markov model was constructed to examine and compare the costs and quality-adjusted life years (QALYs) of the following strategies: (1) IMPT for all patients; (2) IMRT for all patients; and (3) IMPT if efficient. The assumption of equal survival for IMPT and IMRT in the base case analysis was relaxed in a sensitivity analysis. Results: Intensity modulated proton radiation therapy and IMRT for all patients yielded 6.620 and 6.520 QALYs and cost €50,989 and €41,038, respectively. Intensity modulated proton radiation therapy if efficient yielded 6.563 QALYs and cost €43,650. The incremental cost-effectiveness ratio of IMPT if efficient versus IMRT for all patients was €60,278 per QALY gained. In the sensitivity analysis, IMRT was more effective (0.967 QALYs) and less expensive (€8218) and thus dominated IMPT for all patients. Conclusions: Cost-effectiveness analysis based on normal tissue complication probability models and planning studies proved feasible and informative and enables the analysis of individualized strategies. The increased effectiveness of IMPT does not seem to outweigh the higher costs for all head-and-neck cancer patients. However, when assuming equal survival among both modalities, there seems to be value in identifying those patients for whom IMPT is cost-effective.

62 RADIOLOGY AND NUCLEAR MEDICINE↗

Hippocampal Dosimetry Predicts Neurocognitive Function Impairment After Fractionated Stereotactic Radiotherapy for Benign or Low-Grade Adult Brain Tumors

Purpose: To prospectively evaluate the association between hippocampal dose and long-term neurocognitive function (NCF) impairment for benign or low-grade adult brain tumors treated with fractionated stereotactic radiotherapy (FSRT). Methods and Materials: Adult patients with benign or low-grade adult brain tumors were treated with FSRT per institutional practice. No attempt was made to spare the hippocampus. NCF testing was conducted at baseline and 18 months follow-up, on a prospective clinical trial. Regression-based standardized z scores were calculated by using similar healthy control individuals evaluated at the same test-retest interval. NCF impairment was defined as a z score {<=}-1.5. After delineation of the bilateral hippocampi according to the Radiation Therapy Oncology Group contouring atlas, dose-volume histograms were generated for the left and right hippocampi and for the composite pair. Biologically equivalent doses in 2-Gy fractions (EQD{sub 2}) assuming an {alpha}/{beta} ratio of 2 Gy were computed. Fisher's exact test and binary logistic regression were used for univariate and multivariate analyses, respectively. Dose-response data were fit to a nonlinear model. Results: Of 29 patients enrolled in this trial, 18 completed both baseline and 18-month NCF testing. An EQD{sub 2} to 40% of the bilateral hippocampi >7.3 Gy was associated with impairment in Wechsler Memory Scale-III Word List (WMS-WL) delayed recall (odds ratio [OR] 19.3; p = 0.043). The association between WMS-WL delayed recall and EQD{sub 2} to 100% of the bilateral hippocampi >0.0 Gy trended to significance (OR 14.8; p = 0.068). Conclusion: EQD{sub 2} to 40% of the bilateral hippocampi greater than 7.3 Gy is associated with long-term impairment in list-learning delayed recall after FSRT for benign or low-grade adult brain tumors. Given that modern intensity-modulated radiotherapy techniques can reduce the dose to the bilateral hippocampi below this dosimetric threshold, patients should be enrolled in ongoing prospective trials of hippocampal sparing during cranial irradiation to confirm these preliminary results.

62 RADIOLOGY AND NUCLEAR MEDICINE↗

4π Noncoplanar Stereotactic Body Radiation Therapy for Centrally Located or Larger Lung Tumors

Purpose: To investigate the dosimetric improvements in stereotactic body radiation therapy for patients with larger or central lung tumors using a highly noncoplanar 4π planning system. Methods and Materials: This study involved 12 patients with centrally located or larger lung tumors previously treated with 7- to 9-field static beam intensity modulated radiation therapy to 50 Gy. They were replanned using volumetric modulated arc therapy and 4π plans, in which a column generation method was used to optimize the beam orientation and the fluence map. Maximum doses to the heart, esophagus, trachea/bronchus, and spinal cord, as well as the 50% isodose volume, the lung volumes receiving 20, 10, and 5 Gy were minimized and compared against the clinical plans. A dose escalation study was performed to determine whether a higher prescription dose to the tumor would be achievable using 4π without violating dose limits set by the clinical plans. The deliverability of 4π plans was preliminarily tested. Results: Using 4π plans, the maximum heart, esophagus, trachea, bronchus and spinal cord doses were reduced by 32%, 72%, 37%, 44%, and 53% (P≤.001), respectively, and R{sub 50} was reduced by more than 50%. Lung V{sub 20}, V{sub 10}, and V{sub 5} were reduced by 64%, 53%, and 32% (P≤.001), respectively. The improved sparing of organs at risk was achieved while also improving planning target volume (PTV) coverage. The minimal PTV doses were increased by the 4π plans by 12% (P=.002). Consequently, escalated PTV doses of 68 to 70 Gy were achieved in all patients. Conclusions: We have shown that there is a large potential for plan quality improvement and dose escalation for patients with larger or centrally located lung tumors using noncoplanar beams with sufficient quality and quantity. Compared against the clinical volumetric modulated arc therapy and static intensity modulated radiation therapy plans, the 4π plans yielded significantly and consistently improved tumor coverage and critical organ sparing. Given the known challenges in central structure dose constraints in stereotactic body radiation therapy to the lung, 4π planning may increase efficacy and reduce toxicity.

62 RADIOLOGY AND NUCLEAR MEDICINE↗