Engineering Papers⌕ Search

SEARCH · Engineering Papers

Results for “Software estimation,”

Search indexed NASA NTRS and DOE OSTI research on propulsion, heat transfer, battery materials and energy systems. Follow report and document links to the original sources.

Quote a phrase for an exact phrase match. Source license links do not imply unrestricted reuse.

At least 433 records · Page 24

Software reliability perspectives

Software which is used in life critical functions must be known to be highly reliable before installation. This requires a strong testing program to estimate the reliability, since neither formal methods, software engineering nor fault tolerant methods can guarantee perfection. Prior to the final testing software goes through a debugging period and many models have been developed to try to estimate reliability from the debugging data. However, the existing models are poorly validated and often give poor performance. This paper emphasizes the fact that part of their failures can be attributed to the random nature of the debugging data given to these models as input, and it poses the problem of correcting this defect as an area of future research.

Wilson, Larry↗

PyDynamicWindow v1

This software is developed for researchers to evaluate the energy performance of of dynamic windows in the world-wide climate, and this first version focuses on thermochromic windows. We bring new indicators (necessity level and recommendation index) to the evaluation system for thermochromic windows. We estimate the majority users of this software tool will be non-commercial academic researchers. But commercial companies can also use it to optimize their products and estimate where their product has the most promising market.

Gao, Yuan↗

Calibration Software for Use with Jurassicprok

The Jurassicprok Interferometric Calibration Software (also called "Calibration Processor" or simply "CP") estimates the calibration parameters of an airborne synthetic-aperture-radar (SAR) system, the raw measurement data of which are processed by the Jurassicprok software described in the preceding article. Calibration parameters estimated by CP include time delays, baseline offsets, phase screens, and radiometric offsets. CP examines raw radar-pulse data, single-look complex image data, and digital elevation map data. For each type of data, CP compares the actual values with values expected on the basis of ground-truth data. CP then converts the differences between the actual and expected values into updates for the calibration parameters in an interferometric calibration file (ICF) and a radiometric calibration file (RCF) for the particular SAR system. The updated ICF and RCF are used as inputs to both Jurassicprok and to the companion Motion Measurement Processor software (described in the following article) for use in generating calibrated digital elevation maps.

Chapin, Elaine↗

Energy savings potential from improved building controls for the US commercial building sector

The U.S. Department of Energy’s (DOE’s) Building Technologies Office (BTO) sponsored a study to determine the potential national savings achievable in the commercial building sector through widespread deployment of best practice controls, elimination of system and component faults, and use of better sensing. Detailed characterization of potential savings was one source of input to set research, development, and deployment (RD&D) goals in the field of building sensors and controls. DOE’s building energy simulation software, EnergyPlus, was employed to estimate the potential savings from 34 measures in 9 building types and across 16 climates representing almost 57% of commercial building sector energy consumption. In addition to estimating savings from individual measures, three packages of measures were created to estimate savings from the packages. These packages represented an 1) efficient building, 2) typical building, and 3) inefficient building. To scale the results from individual measures or a package to the national scale, building weights by building type and climate locations from the Energy Information Administration’s 2012 Commercial Building Energy Consumption Survey (CBECS) were used. The results showed significant potential for energy savings across all building types and climates. The total site potential savings from individual measures by building type and climate location ranged between 0% and 25%. The total site potential savings by building type aggregated across all climates (using the CBECS building weights) for each measure varied between 0% and 16%. The total site potential savings aggregated across all building types and climates for each measure varied between 0% and 11%. Some individual measures had negative savings because correcting underlying operational problems (e.g., inadequate ventilation) resulted in increased energy consumption. When combined into packages, the overall national savings potential is estimated to be 29%; seven of the nine building types were in the range of 23 to 29% and two exceeded 40%. The total potential national site savings in for each building type ranged between 95x106 GJ (0.09 Quadrillion British thermal units [Quads]; Large Hotels) to 222x106 GJ (0.21 Quads; Large Office, Hospital Administrative areas, and College/University), resulting in total site savings of 1,393x106 GJ (1.32 Quads) when the three packages are applied to the U.S. commercial buildings stock. Using the source (or primary) energy conversion factors of 1.05 for natural gas and 3.14 for electricity resulted in an approximate potential primary energy savings of 2,912x106 GJ (2.76 Quads), which would be 15% of the sector’s 2015 use of approximately 18,991x106 GJ (18 Quads). Extrapolating the results for other building types not analyzed as part of this study, the primary energy savings could be in the range of 4,220x106 GJ to 5,275x106 GJ (4 to 5 Quads). If this savings potential is realized, it would be equivalent to not combusting 180 to 230 million tons of coal or reducing the energy impacts, at today’s energy intensities, of the per capita consumption of 12 to 15 million people in the U.S. To realize most of this potential savings, many gaps can be addressed through RD&D, as recommended in this paper.

Fernandez, Nick↗

A Machine Learning Framework for Predicting Microphysical Properties of Ice Crystals From Cloud Particle Imagery

The microphysical properties of ice crystals are important because they significantly alter the radiative properties and spatiotemporal distributions of clouds, which in turn strongly affect Earth's climate. However, it is challenging to measure key properties of ice crystals, such as mass or morphological features. Here, we present a proof-of-concept framework for predicting three-dimensional (3D) microphysical properties of ice crystals from in situ two-dimensional (2D) imagery. First, we computationally generated synthetic ice crystals using 3D modeling software along with geometric parameters estimated from the 2021 Ice Cryo-Encapsulation Balloon (ICEBall) field campaign. Then, we used synthetic crystals to train machine learning (ML) models to predict effective density ($ρ_e$), effective surface area ($A_e$), and number of bullets ($N_b$) from synthetic rosette imagery. On unseen synthetic images, our ML models accurately predicted ice crystal properties. ResNet-18 performed best, achieving $R^2$ values of 0.99 and 0.98 for $ρ_e$ and $A_e$, respectively, and MAE of 0.10 for mathematical equation in single view tasks. Stereo view ResNet-18 further reduced RMSE by 40% for $ρ_e$ and $A_e$ and reduced MAE by 0.08 for $N_b$. This work provides a novel ML-driven framework for estimating ice microphysical properties from in situ imagery, which will allow for downstream constraints on microphysical parameterizations, such as the mass-size relationship.

Ko, J. [Columbia Univ., New York, NY (United State↗

Rneshaps

This software is used to combine output files US EPA CAp88-PC software (http://www.epa.gov/radiation/assessment/CAP88/aboutcap88.html) and estimate input parameters for CAP88-PC. Also includes features for tabular and graphical review of results.

MacQueen, D.H.↗

Moving Toward an Optimal and Automated Geospatial Network for CCUS Infrastructure

Modifications in the global climate are being driven by the anthropogenic release of greenhouse gases (GHG) including carbon dioxide (CO 2 ) (Middleton et al. 2014). CO 2 emissions have, for example, been directly linked to an increase in total global temperature (Seneviratne et al. 2016). Strategies that limit CO 2 emissions—like CO 2 capture, utilization, and storage (CCUS) technology—can greatly reduce emissions by capturing CO 2 before it is released to the atmosphere. However, to date CCUS technology has not been developed at a large commercial scale despite several promising high profile demonstration projects (Middleton et al. 2015). Current CCUS research has often focused on capturing CO 2 emissions from coal-fired power plants, but recent research at Los Alamos National Laboratory (LANL) suggests focusing CCUS CO 2 capture research upon industrial sources might better encourage CCUS deployment. To further promote industrial CCUS deployment, this project builds off current LANL research by continuing the development of a software tool called SimCCS, which estimates a regional system of transport to inject CO 2 into sedimentary basins. The goal of SimCCS, which was first developed by Middleton and Bielicki (2009), is to output an automated and optimal geospatial industrial CCUS pipeline that accounts for industrial source and sink locations by estimating a Delaunay triangle network which also minimizes topographic and social costs (Middleton and Bielicki 2009). Current development of SimCCS is focused on creating a new version that accounts for spatial arrangements that were not available in the previous version. This project specifically addresses the issue of non-unique Delaunay triangles by adding additional triangles to the network, which can affect how the CCUS network is calculated.

54 ENVIRONMENTAL SCIENCES↗

Fast BLT Code

This note discusses numerical algorithmic software design considerations and performance estimates for a fast BLT coupling code [1] written in c++. The aim of this code is to conduct faster parameter studies over line orientations. The original matlab code was written by Mike Rivera. Art Barnes ported this code to julia. I rewrote portions of the code for speed improvement, mainly to eliminate some redundant computation when calculating many line orientations. But this code is still far from optimal.

97 MATHEMATICS AND COMPUTING↗

Analysis of ISOCS Measurements to Establish Methodology Uncertainty

Qualification measurements were performed at the US Department of Energy’s (DOE’s) Oak Ridge National Laboratory (ORNL) on a variety of measurement standards. These measurements will be used to qualify the In-Situ Object Counting System (ISOCS) measurement method with a high-purity germanium (HPGe) detector for use at ORNL. Measured items include uranium isotopic standards, filter papers coated with uranium oxide (U 3 O 8 ), U 3 O 8 line sources, and a uranium tetrafluoride (UF 4 ) source. The 235 U mass was estimated using the ISOCS calibration software for each source and compared with the declared isotope mass value.

46 INSTRUMENTATION RELATED TO NUCLEAR SCIENCE AND ↗

Human Dosimetry and Preliminary Tumor Distribution of (superscript)18F-Fluoropaclitaxel in Healthy Volunteers and Newly Diagnosed Breast Cancer Patients Using PET/CT

{sup 18}F-fluoropaclitaxel is a radiolabeled form of paclitaxel, a widely used chemotherapy agent. Preclinical data suggest that {sup 18}F-fluoropaclitaxel may be a reasonable surrogate for measuring the uptake of paclitaxel. As a substrate of P-glycoprotein, a drug efflux pump associated with multidrug resistance, {sup 18}F-fluoropaclitaxel may also be useful in identifying multidrug resistance and predicting tumor response for drugs other than paclitaxel. After informed consent was obtained, 3 healthy volunteers and 3 patients with untreated breast cancer (neoadjuvant chemotherapy candidates, tumor size > 2 cm) received an intravenous infusion of {sup 18}F-fluoropaclitaxel and then underwent PET/CT. Healthy volunteers underwent serial whole-body imaging over an approximately 3-h interval, and organ {sup 18}F residence times were determined from the time-activity curves uncorrected for decay to determine dosimetry. Radiation dose estimates were calculated using OLINDA/EXM software. For breast cancer patients, dynamic imaging of the primary tumor was performed for 60 min, followed by static whole-body scans at 1 and 2 h after injection. Dosimetry calculations showed that the gallbladder received the highest dose (229.50 {mu}Gy/MBq [0.849 rad/mCi]), followed by the small and large intestines (161.26 {mu}Gy/MBq [0.597 rad/mCi] and 184.59 {mu}Gy/MBq [0.683 rad/mCi]). The resultant effective dose was 28.79 {mu}Gy/MBq (0.107 rem/mCi). At approximately 1 h after injection, an average of 42% of the decay-corrected activity was in the gastrointestinal system, with a mean of 0.01% in the tumor. All 3 breast cancer patients showed retention of {sup 18}F-fluoropaclitaxel and ultimately demonstrated a complete pathologic response (no invasive cancer in the breast or axillary nodes) to chemotherapy that included a taxane (either paclitaxel or docetaxel) at surgical resection. The tumor-to-background ratio increased with time to a maximum of 7.7 at 20 min. This study demonstrates the feasibility of using {sup 18}F-fluoropaclitaxel PET/CT tumor imaging and provides radiation dosimetry measurements in humans. Although further study is needed, it is hoped that the measured intratumoral {sup 18}F-fluoropaclitaxel distribution can serve as a surrogate for paclitaxel, and potentially other chemotherapeutic agent retention, in solid tumors.

18F-Fluoropaclitaxel (FPAC)↗

Level B/C software ground navigation program. Delta-T processor

The Delta-T Processor (DTP) computes the instantaneous downtrack error in a specified orbiter onboard navigation state vector recovered via downlink telemetry. The downtrack error, expressed in units of time, is computed based on current incoming Earth based range and Doppler navigation tracking data and the ground selected onboard navigation state vector. The computed time difference when used to modify the timetag of the vector used for onboard navigation reduces the instantaneous downtrack error in this vector to within the threshold of the DTP, the input data, and the onboard software. This threshold is currently estimated to be approximately 2 to 4 nautical miles. The DTP is not restricted to using only onboard vectors. Any vector, either input via the manual entry device or accessible via the vector administration table, may be used. The DTP does not require that both data types be available.

Source record↗

An experimental evaluation of software redundancy as a strategy for improving reliability

The strategy of using multiple versions of independently developed software as a means to tolerate residual software design faults is suggested by the success of hardware redundancy for tolerating hardware failures. Although, as generally accepted, the independence of hardware failures resulting from physical wearout can lead to substantial increases in reliability for redundant hardware structures, a similar conclusion is not immediate for software. The degree to which design faults are manifested as independent failures determines the effectiveness of redundancy as a method for improving software reliability. Interest in multi-version software centers on whether it provides an adequate measure of increased reliability to warrant its use in critical applications. The effectiveness of multi-version software is studied by comparing estimates of the failure probabilities of these systems with the failure probabilities of single versions. The estimates are obtained under a model of dependent failures and compared with estimates obtained when failures are assumed to be independent. The experimental results are based on twenty versions of an aerospace application developed and certified by sixty programmers from four universities. Descriptions of the application, development and certification processes, and operational evaluation are given together with an analysis of the twenty versions.

Eckhardt, Dave E., Jr.↗

Advanced transport operating system software upgrade: Flight management/flight controls software description

The Flight Management/Flight Controls (FM/FC) software for the Norden 2 (PDP-11/70M) computer installed on the NASA 737 aircraft is described. The software computes the navigation position estimates, guidance commands, those commands to be issued to the control surfaces to direct the aircraft in flight based on the modes selected on the Advanced Guidance Control System (AGSC) mode panel, and the flight path selected via the Navigation Control/Display Unit (NCDU).

Clinedinst, Winston C.↗

Power system state estimation for a spacecraft power system

An application of the maximum likelihood state estimator to a space-based power system is presented. The state estimator uses current and voltage measurements to generate estimates of node voltages for an electrical power distribution system for the Space Shuttle. Preliminary results on the effect of noisy measurements on estimated parameters are reported. The software used in generating these results is part of an overall package being developed at Louisiana Tech University. Intended applications of this package include the analysis of power systems and real-time parallel processing on the Space Shuttle.

Berry, F. C.↗

An experimental evaluation of software redundancy as a strategy for improving reliability

The strategy of using multiple versions of independently developed software as a means to tolerate residual software design faults is suggested by the success of hardware redundancy for tolerating hardware failires. Although, as generally accepted, the independence of hardware failures resulting from physical wearout can lead to substantial increases in reliability for redundant hardware structures, a similar conclusion is not immediate for software. The degree to which design faults are manifested as independent failures determines the effectiveness of redundancy as a method for improving software reliability. Interest in multi-version software centers on whether it provides an adequate measure of increased reliability to warrant its use in critical applications. The effectiveness of multi-version software is studied by comparing estimates of the failure probabilities of these systems with the failure probabilities of single versions. The estimates are obtained under a model of dependent failures and compared with the estimates obtained when failures are assumed to be independent. The experimental results are based on twenty versions of an aerospace application developed and certified by sixty programmers from four universities. Descriptions of the application, development and certifications processes, and operational evaluation are given together with an analysis of the twenty versions.

Eckhardt, Dave E.↗

DORIS Satellite Phase Center Determination and Consequences on the Derived Scale of the Terrestrial Reference Frame

This slide presentation reports on the analysis of several years of Delft Object-oriented Radar Interferometric Software (Doris) data undertaken to estimate daily determination of satellite antenna phase center corrections. This was done on a satellite by satellite basis. For each DORIS satellite, we considered long-term time series of such individual estimations, looking for possible biases, discontinuities, trends or annual signals. The analysis compared DORIS to GPS estimates for common satellites (Jason and TOPEX/Poseidon).

terrestrial reference frame scale↗

NASA Tech Briefs, October 2007

Topics covered include; Wirelessly Interrogated Position or Displacement Sensors; Ka-Band Radar Terminal Descent Sensor; Metal/Metal Oxide Differential Electrode pH Sensors; Improved Sensing Coils for SQUIDs; Inductive Linear-Position Sensor/Limit-Sensor Units; Hilbert-Curve Fractal Antenna With Radiation- Pattern Diversity; Single-Camera Panoramic-Imaging Systems; Interface Electronic Circuitry for an Electronic Tongue; Inexpensive Clock for Displaying Planetary or Sidereal Time; Efficient Switching Arrangement for (N + 1)/N Redundancy; Lightweight Reflectarray Antenna for 7.115 and 32 GHz; Opto-Electronic Oscillator Using Suppressed Phase Modulation; Alternative Controller for a Fiber-Optic Switch; Strong, Lightweight, Porous Materials; Nanowicks; Lightweight Thermal Protection System for Atmospheric Entry; Rapid and Quiet Drill; Hydrogen Peroxide Concentrator; MMIC Amplifiers for 90 to 130 GHz; Robot Would Climb Steep Terrain; Measuring Dynamic Transfer Functions of Cavitating Pumps; Advanced Resistive Exercise Device; Rapid Engineering of Three-Dimensional, Multicellular Tissues With Polymeric Scaffolds; Resonant Tunneling Spin Pump; Enhancing Spin Filters by Use of Bulk Inversion Asymmetry; Optical Magnetometer Incorporating Photonic Crystals; WGM-Resonator/Tapered-Waveguide White-Light Sensor Optics; Raman-Suppressing Coupling for Optical Parametric Oscillator; CO2-Reduction Primary Cell for Use on Venus; Cold Atom Source Containing Multiple Magneto- Optical Traps; POD Model Reconstruction for Gray-Box Fault Detection; System for Estimating Horizontal Velocity During Descent; Software Framework for Peer Data-Management Services; Autogen Version 2.0; Tracking-Data-Conversion Tool; NASA Enterprise Visual Analysis; Advanced Reference Counting Pointers for Better Performance; C Namelist Facility; and Efficient Mosaicking of Spitzer Space Telescope Images.

Source record↗

Autonomous Aerobraking: A Design, Development, and Feasibility Study

Aerobraking has been used four times to decrease the apoapsis of a spacecraft in a captured orbit around a planetary body with a significant atmosphere utilizing atmospheric drag to decelerate the spacecraft. While aerobraking requires minimum fuel, the long time required for aerobraking requires both a large operations staff, and large Deep Space Network resources. A study to automate aerobraking has been sponsored by the NASA Engineering and Safety Center to determine initial feasibility of equipping a spacecraft with the onboard capability for autonomous aerobraking, thus saving millions of dollars incurred by a large aerobraking operations workforce and continuous DSN coverage. This paper describes the need for autonomous aerobraking, the development of the Autonomous Aerobraking Development Software that includes an ephemeris estimator, an atmospheric density estimator, and maneuver calculation, and the plan forward for continuation of this study.

Prince, Jill L. H.↗