At least 433 records · Page 24

A Scalable Solution for Grid Optimization and DER Integration (CRADA Final Report)

Utilidata Inc. is an energy software company that provides clean energy and digital solutions for utilities. This work was the result of Utilidata Inc. being awarded a New York State Energy Research and Development Agency award to integrate Utilidata volt-VAR optimization (VVO) software with smart inverters to explore enhanced voltage control. This project was conducted in partnership with Utilidata Inc., National Grid, the New York State Energy and Research Development Authority, and the National Renewable Energy Laboratory (NREL). As part of the project NREL conducted modeling and simulation analysis, developed cost-benefit analysis framework, and conducted laboratory testing to understand the potential for smart inverter integration to a centralized VVO control scheme. The remainder of the report provides an executive summary of the work, an introduction to the challenges, sections detailing specific aspects of the work, and the overall findings and conclusions.

14 SOLAR ENERGY↗

Smart Charging of Fleet and Personal Electric Vehicles through Joint Vehicle-to-Grid Optimization

As electric vehicle (EV) adoption accelerates, vehicle-to-grid (V2G) strategies offer advantages over unmanaged charging (V0G) by enhancing grid stability, reducing fleet operation costs, and supporting integration of variable generation resources. This research develops a day-ahead optimization framework linked with agent-based simulations to evaluate coordinated V2G participation by fleet and personal EVs under 5 energy-pricing settings in Austin, Texas. Three scenarios (V0G, fleet-only V2G, and joint-V2G) are examined, considering real-time price and grid profiles, health-damage costs, and operational constraints for both fleet and personal EVs. Results show how V2G scenarios shift fleet EV charging to mid-day while enabling strategic battery-discharge during evening peaks, mitigating grid stress and lowering EV energy costs. V2G delivers close to 80% energy-cost savings for a 2000-EV fleet in Austin on grid-stressed days, with 55% lower charging pollutant outputs. Joint-V2G amplifies system-level benefits by complementing fleet discharge, but smart-charging equipment costs can offset those benefits.

Electric vehicle↗

On the Use of Smart Meter Data to Estimate the Voltage Magnitude on the Primary Side of Distribution Service Transformers

This paper develops a novel method to estimate the voltage magnitude on the primary side of distribution service transformers. The proposed method relies exclusively on smart meters, and therefore it is fully data-driven. This is an important feature because electric utilities have detailed models of only the primary network - that is, the network between the distribution substation and the primary side of service transformers that are installed closer to end-customer sites. The network that connects the secondary side of service transformers to end-customer sites, referred to as the secondary network, is simply represented by a lumped load. For each secondary network, the proposed method uses data acquired from only 2 smart meters: the closest and the farthest-in the sense of electrical distance - from the service transformer. As a reference to this feature, the proposed method is named SM2Vp. To our knowledge, this is the first time a method is shown to provide actionable information for realtime operation and control of power distribution grids using only two smart meters per secondary network. This is important because utilities have experienced barriers in managing and using large data sets for real-time operation and control. SM2Vp is primarily intended to provide pseudo-measurements for distribution system state estimation, but it can also be used directly for voltage control schemes. The performance of SM2Vp is demonstrated by numerical simulations carried out on three secondary network synthetic models and by using field data provided by a utility partner serving customers in southwestern California. A maximum relative error of approximately 3.9% or less is observed for the primary voltage magnitude estimates in all numerical experiments.

distribution service transformer↗

On the Use of Smart Meter Data to Estimate the Voltage Magnitude on the Primary Side of Distribution Service Transformers: Preprint

This paper develops a novel method to estimate the voltage magnitude on the primary side of distribution service transformers. The proposed method relies exclusively on smart meters, and therefore it is fully data-driven. This is an important feature because electric utilities have detailed models of only the primary network--that is, the network between the distribution substation and the primary side of service transformers that are installed closer to end-customer sites. The network that connects the secondary side of service transformers to end-customer sites, referred to as the secondary network, is simply represented by a lumped load. For each secondary network, the proposed method uses data acquired from only 2 smart meters: the closest and the farthest--in the sense of electrical distance--from the service transformer. As a reference to this feature, the proposed method is named SM2Vp. To our knowledge, this is the first time a method is shown to provide actionable information for real-time operation and control of power distribution grids using only two smart meters per secondary network. This is important because utilities have experienced barriers in managing and using large data sets for real-time operation and control. SM2Vp is primarily intended to provide pseudo-measurements for distribution system state estimation, but it can also be used directly for voltage control schemes. The performance of SM2Vp is demonstrated by numerical simulations carried out on three secondary network synthetic models and by using field data provided by a utility partner serving customers in southwestern California. A maximum relative error of approximately 3.9% or less is observed for the primary voltage magnitude estimates in all numerical experiments.

70 PLASMA PHYSICS AND FUSION TECHNOLOGY↗

Recursive Gaussian Process over graphs for Integrating Multi-timescale Measurements in Low-Observable Distribution Systems

The transition to a smarter grid is empowered by enhanced sensor deployments and smart metering infrastructure in the distribution system. Measurements from these sensors and meters can be used for many applications, including distribution system state estimation (DSSE). However, these measurements are typically sampled at different rates and could be intermittent due to losses during the aggregation process. These multi timescale measurements should be reconciled in real-time to perform accurate grid monitoring. This paper tackles this problem by formulating a recursive multi-task Gaussian process (RGP-G) approach that sequentially aggregates sensor measurements. Specifically, we formulate a recursive multi-task GP with and without network connectivity information to reconcile the multi time-scale measurements in distribution systems. Here, the proposed framework is capable of aggregating the multi-time scale measurements batch-wise or in real-time. Following the aggregation of the multi time-scale measurements, the spatial states of the consistent time-series are estimated using matrix completion based DSSE approach. Simulation results on IEEE 37 and IEEE 123 bus test systems illustrate the efficiency of the proposed methods from the standpoint of both multi time-scale data aggregation and DSSE.

42 ENGINEERING↗

Bio-Based Phase Change Materials (PCMs) for Thermal Energy Storage (Final Scientific/Technical Report)

The goal of this project is to develop a novel bio-based phase change material (PCM) derived from squid ring teeth (SRT) proteins, and design a prototype heat exchanger based on these bio-based PCMs for energy storage and dynamic heat exchange for building thermal energy storage systems. The PCMs, derived from SRT proteins, will demonstrate room temperature energy storage capacities and switchable thermal conductivities that redefine the current state-of-the-art (SOA) for building thermal energy storage. Further, in a single material and with a single manufacturing processes, our proposed thermal battery will be developed with “on demand” thermal conductivity for rapid charging/discharging but superior insulation during energy storage periods. More specifically, our bio-based PCMs have demonstrated: 1) the potential for increased energy storage capacity (i.e., greater than paraffines at room temperature); 2) tunability in thermal conductivity with the largest thermal conductivity switching ratios for an intrinsic material reported to date, and 3) a 100% recyclable and biodegradable PCM with low volatility and toxicity and scalability in its manufacture for both residential and commercial applications. The already established ability for roll-to-roll processing of these non-toxic, non-flammable SRT composites along with their carbon-neutral manufacturing processes that has been pioneered by our team make this solution a disruptive and impactful technology to redefine the current SOA of energy storage technologies. The outcomes of this effort have been: 1) the identification of new bio-based PCM that establishes a new SOA for thermal conductivity and energy storage density at room temperature and 2) the development of a new experimental technique to measure the energy storage density via latent heat measurements during melting of thin films. This new technique can be applied to thin films (as thin as < 1 micrometer), and represents a novel approach for thin film energy storage density measurements. Dynamic thermal energy storage is the missing technology that will enable a grid- interactive efficient building (GEB). For a “smart” building capable of connecting with the power grid, the media must be inexpensive and possess thermal switching capabilities to control the time-dependent heat flow into (and out of) the PCM on demand. Unique to the material system in this program, programmable SRT-based PCM show improvements as compared to traditionally used PCMs, and thus its technical performance will represent a leap forward for the future GEB concept.

25 ENERGY STORAGE↗

Hybrid Modeling of Three-Phase Grid-Supporting Inverters for Dynamic Studies

Grid technologies connected by power electronic converter (PEC) interfaces continually implement grid support functions mandated by grid codes and standards. The transition to converter-based generation demands precise PEC models to assess system dynamics, which have been previously overlooked in conventional power systems. This study proposes a hybrid method for analyzing grid-connected three-phase PEC dynamics with the IEEE standard 1547-2018 Volt-VAr mode that combines physics and data-driven techniques. The physics model reflects the PEC’s internal behavior, whereas the data-driven modeling technique evaluates the grid-supporting capabilities of the smart PEC. The system identification approach is used to generate dynamic PEC models based on changing grid voltage and measured current injected into the grid by the PEC. In the Volt-VAr support mode, a detailed topological model including switches is utilized to compare the goodness-of-fit of the extracted hybrid dynamic model. The results demonstrate that the hybrid PEC model in the Volt-VAr mode accurately matches the dynamics with the topological model.

Subedi, Sunil↗

Smart Meter Pinging and Reading Through AMI Two-Way Communication Networks to Monitor Grid Edge Devices and DERs

Today’s power distribution system is changing to a power-electronics-enabled distribution system, especially with the increasing penetration of distributed energy resources (DERs). To monitor and manage those electronic devices and DERs at the grid edge, the advanced metering infrastructure (AMI) with two-way communications presents great potential. At present, extensive research explores the upstream communication from smart meters to electric utilities (e.g., meter reading) but few examine the downstream communication from the utilities to smart meters (e.g., meter pinging). This article discusses the AMI two-way communication and its recent industrial practice in the U.S., especially for applying the smart meter pinging functionality to monitor grid-edge devices and DERs. This paper then develops the two-way communication model and the network calculus method to quantify the impact of the two-way communication on the AMI network. In the end, the proposed method is validated with ns-3 simulation using the modified 13-node test feeder and real-world feeder systems.

24 POWER TRANSMISSION AND DISTRIBUTION↗

WHISPER: Wireless Home Identification and Sensing Platform for Energy Reduction

Many regions of the world benefit from heating, ventilating, and air-conditioning (HVAC) systems to provide productive, comfortable, and healthy indoor environments, which are enabled by automatic building controls. Due to climate change, population growth, and industrialization, HVAC use is globally on the rise. Unfortunately, these systems often operate in a continuous fashion without regard to actual human presence, leading to unnecessary energy consumption. As a result, the heating, ventilation, and cooling of unoccupied building spaces makes a substantial contribution to the harmful environmental impacts associated with carbon-based electric power generation, which is important to remedy. For our modern electric power system, transitioning to low-carbon renewable energy is facilitated by integration with distributed energy resources. Automatic engagement between the grid and consumers will be necessary to enable a clean yet stable electric grid, when integrating these variable and uncertain renewable energy sources. We present the WHISPER (Wireless Home Identification and Sensing Platform for Energy Reduction) system to address the energy and power demand triggered by human presence in homes. The presented system includes a maintenance-free and privacy-preserving human occupancy detection system wherein a local wireless network of battery-free environmental, acoustic energy, and image sensors are deployed to monitor homes, record empirical data for a range of monitored modalities, and transmit it to a base station. Several machine learning algorithms are implemented at the base station to infer human presence based on the received data, harnessing a hierarchical sensor fusion algorithm. Results from the prototype system demonstrate an accuracy in human presence detection in excess of 95%; ongoing commercialization efforts suggest approximately 99% accuracy. Using machine learning, WHISPER enables various applications based on its binary occupancy prediction, allowing situation-specific controls targeted at both personalized smart home and electric grid modernization opportunities.

32 ENERGY CONSERVATION, CONSUMPTION, AND UTILIZATI↗

Stochastic Microgrid Scheduling With Chance‐Constrained Resilience Consideration

Traditionally, it is assumed that microgrids transition seamlessly from grid‐connected operation to islanded mode in the event of sudden main grid outages. In reality, the islanding process, especially unintentional islanding, is rarely seamless. Instead, it is subject to voltage and frequency fluctuations caused by the instantaneous disconnection of the point of common coupling (PCC) switch, variations in loads and renewable generation output and even the protection tripping of distributed energy resources (DERs). To mitigate these fluctuations and facilitate a smooth islanding process, we propose a stochastic microgrid scheduling model that incorporates chance‐constrained resilience measures. Specifically, the resilience measure is defined as the probability of successful islanding (PSI), that is, the probability that a microgrid can mitigate the generation‐demand imbalance caused by the disconnection of the PCC switch, variations in load and renewable generation and DER tripping. This measure is modelled using chance constraints. Unlike existing reliability and resilience indices, which typically neglect the possibility of microgrid/DER failure under extreme events and assume their survival while primarily focussing on reducing impact duration or magnitude, the proposed PSI‐based framework explicitly addresses microgrid and DER survival during the islanding transition. The formulated nonlinear chance constraints are approximated using a multiinterval approach and equivalently represented as a mixed‐integer linear programming (MILP) formulation. Case study results validate the proposed method, showing that the PSI estimation error is reduced to less than 8%, compared to approximately 28% with existing methods. Various sensitivity analyses on the DER tripping rate and PSI settings were performed to validate the robustness of the proposed method. In particular, the necessity of accounting for DER tripping in the PSI calculation was demonstrated.

chance constrained optimization↗

Distribution Transformer Health Monitoring using Smart Meter Data

The distribution electric grid has become a highly complex and intelligent network with changing load and customer types. This has generated unprecedented challenges and opportunities for utility companies–opportunities especially in the area of asset health/performance management. Moreover, several utilities are increasingly moving from the traditional reactive and time-based asset monitoring approach to a more proactive condition based method. However, this needs to be done in a low-cost and efficient manner. Here, this paper explores how existing sensor infrastructure such as smart meters can be utilized to provide utility operators with more visibility into the health and operation of their assets. The paper focuses primarily on service transformers.

24 POWER TRANSMISSION AND DISTRIBUTION↗

Cognitive IoT and Edge Computing for Intrusion Detection with Federated TinyML

Internet of Things (IoT) and Edge Computing (EC) are rapidly becoming an integral part of the modern society. By 2030, there is estimated to be over 40 billion active and connected IoT devices [1]. This rapid progress also comes with a significant implication on cybersecurity. Back-end infrastructure and systems have a much broader attack than they did previously due to vulnerable IoT/EC devices being connected to wireless networks. This expanding attack surface is a growing concern because IoT/EC are increasingly being used in critical systems such as power grids, health care, and smart homes. To effectively address a problem of this scale, cognitive cyber methods—which can autonomously detect and react to cyber attacks as they develop—are needed. To address this, we bring Artificial Intelligence (AI) and Machine Learning (ML) to IoT/EC devices, using tinyML to monitor voluminous IoT data against cyber threats, and using Federated Learning (FL) to share local detection knowledge across the system while preserving privacy. We propose a novel three-layer architecture: (1) an IoT layer for tinyML-based inference, (2) an edge layer for ML model training, and (3) a cloud layer for FL operations. Using the publicly available 11-class N-BaIoT dataset [2], we demonstrate that this architecture mitigates resource constraints at the IoT layer while improving detection accuracy over standard two-layer designs. An outlier-resistant scaler, feature reduction, and quantization enable the tinyML model to maintain detection accuracy with a reduced model size. Additionally, federated learning that only utilizes the intersection (across heterogenous devices) of the reduced feature set achieves superior detection accuracy compared to locally trained models.

Li, Mingyan [ORNL] (ORCID:0009000569532640)↗

Enabling Extreme Fast Charging with Energy Storage Final Report

The objective of this project was to develop and demonstrate an extreme fast charging (XFC) station with three 350 kW charging ports that operate at a combined power exceeding 1 MW and mitigate the grid impact by employing smart charging algorithms, using an energy storage system, and connecting directly to a medium-voltage (15 kV-class three-phase) distribution feeder. This final report describes the team's achievements in all aspects of the technology development.

24 POWER TRANSMISSION AND DISTRIBUTION↗

A Multi-Objective Approach for Optimizing Edge-Based Resource Allocation Using TOPSIS

Existing approaches for allocating resources on edge environments are inefficient and lack the support of heterogeneous edge devices, which in turn fail to optimize the dependency on cloud infrastructures or datacenters. To this extent, we propose in this paper OpERA, a multi-layered edge-based resource allocation optimization framework that supports heterogeneous and seamless execution of offloadable tasks across edge, fog, and cloud computing layers and architectures. By capturing offloadable task requirements, OpERA is capable of identifying suitable resources within nearby edge or fog layers, thus optimizing the execution process. Throughout the paper, we present results which show the effectiveness of our proposed optimization strategy in terms of reducing costs, minimizing energy consumption, and promoting other residual gains in terms of processing computations, network bandwidth, and task execution time. We also demonstrate that by optimizing resource allocation in computation offloading, it is then possible to increase the likelihood of successful task offloading, particularly for computationally intensive tasks that are becoming integral as part of many IoT applications such robotic surgery, autonomous driving, smart city monitoring device grids, and deep learning tasks. The evaluation of our OpERA optimization algorithm reveals that the TOPSIS MCDM technique effectively identifies optimal compute resources for processing offloadable tasks, with a 96% success rate. Moreover, the results from our experiments with a diverse range of use cases show that our OpERA optimization strategy can effectively reduce energy consumption by up to 88%, and operational costs by 76%, by identifying relevant compute resources.

97 MATHEMATICS AND COMPUTING↗

Discovering the Most Severe K-Point Failure Based on Reinforcement Learning: Preprint

Smart devices are essential to ensure the stability of the power grid and resilience to intermittent energy production. However, smart devices can also be the target of cyber adversaries that may exploit false data injection attacks (FDIAs) to induce unstable grid conditions. A practical consideration of FDIA mitigation approaches is addressed here: given a finite available budget, for which smart device should cyber-threat mitigation be deployed first? In this work, this question is answered by identifying the so-called most-sensitive devices, i.e., the devices that, if compromised, can let an adversary induce the most serious grid instabilities. The method proposed utilizes an adversarial reinforcement learning (RL) framework to identify the k-mostsensitive smart devices (here, smart inverters). The adversarial agent can tamper with the compromised inverters' active and reactive operating power setup points, with the goal of maximizing voltage deviations. Numerical results show that the proposed RL method finds the optimal attack scenarios for 1-point failure and the near-optimal solution for the 2-point case. Additionally, the proposed RL method achieves an 8.8 speed-up ratio in running time compared to the brute force method for the 2-point case.

97 MATHEMATICS AND COMPUTING↗

Simplified Transactive Distribution Grids for Bulk Power System Mechanism Development

As distributed energy resources and smart devices become omnipresent in the electrical power grid, transactive energy control mechanisms are evolving. From real-time to day-ahead markets, these transactive energy algorithms involve more and more agents, whose behavior is going to affect the transmission and generation network. In order to study the interaction between the wholesale and retail energy markets, extensive co-simulations are performed. To be able to redesign, evaluate, and verify new control algorithms, the simulations need to provide results in a fast and reliable manner. This work has built and tested a transactive distribution grid model, the DSO-Stub, meant to offer a configurable distribution retail market while ensuring the computational burden is not significantly increased.

Transactive Energy, , Distribution System Operator↗

Autonomous Restoration of Networked Microgrids Using Communication-Free Smart Sensing and Protection Units

Here this paper presents autonomous restoration of networked microgrids using distributed energy resources (DERs), inverter-based resources (IBRs) in general, and controllable assets of intelligence without communication to achieve a extremely resilient power system restoration. The main innovation of this work lies in use of real-time smart sensing and decision making that enable autonomous recombination of islanded microgrids, which are individually black-started by local grid-forming (GFM) inverter units. The smart circuit breakers (SCBs) designed and demonstrated here play critical roles in the restoration process to achieve autonomy; the autonomous restoration scheme is not pre-engineered and may be subject to encounter overloading, live or downed segments as the boundary of the microgrids dynamically expands without prior knowledge and only with local measurement. We demonstrate autonomous microgrid restoration both in simulation of a modified IEEE 13-bus system, and in a hardware testbed comprising 24 GFM-IBRs and 6-SCBs, depicting several scenarios to evaluate their functionalities and interoperability. This work validates high potential of extremely resilient microgrid using novel approaches for inverter-based bottom-up system restoration in a communication-free paradigm.

24 POWER TRANSMISSION AND DISTRIBUTION↗

Architecture of a Residential Solid State Power Substation (SSPS) Node

High integration rates of new loads and distributed generation at the edge of the grid are posing new challenges. However, existing smart power electronic systems are not designed to coordinate and maximize grid support or provide multiple grid services simultaneously. This work presents the application of a solid-state power substation (SSPS) to residential systems to increase this coordination and reduce future challenges. The proposed residential SSPS is validated in simulation including power electronic converter models, feeder models, and optimization.