Engineering Papers⌕ Search

SEARCH · Engineering Papers

Results for “Signal Detection”

Search indexed NASA NTRS and DOE OSTI research on propulsion, heat transfer, battery materials and energy systems. Follow report and document links to the original sources.

Quote a phrase for an exact phrase match. Source license links do not imply unrestricted reuse.

At least 433 records · Page 24

Investigation of a digitizer for the plastic scintillation detectors of time-of-flight mass measurements

A CAEN DT5742 digitizer has been investigated to process the fast signals from the photomultiplier tubes of the time-of-flight detectors for fast ion beams. A test setup consisting of two plastic scintillation detectors and a pulsed laser source provided signals which were recorded by the digitizer and systematically analyzed with different algorithms to derive the amplitude, rise time and arrival time of the detection signal. To obtain the best amplitude and time resolutions, various optimization techniques including peak fitting and signal smoothing, interpolation improvement, and time-walk correction by amplitude and rise time have been performed and compared in detail. Here we compared the time resolutions obtained by three digital algorithms of leading-edge, zero-crossing constant-fraction (ZC-CFD) and direct constant-fraction discriminations. Finally, we found that the best time-of-flight resolution between two PMTs can be achieved as 12 ps by the method using sample minimum for peak location and using the time-walk-resistant ZC-CFD with 4-point interpolation for timing.

46 INSTRUMENTATION RELATED TO NUCLEAR SCIENCE AND ↗

System for plotting subsoil structure and method therefor

Data for use in producing a tomograph of subsoil structure between boreholes is derived by pacing spaced geophones in one borehole, on the Earth surface if desired, and by producing a sequence of shots at spaced apart locations in the other borehole. The signals, detected by each of the geophones from the various shots, are processed either on a time of arrival basis, or on the basis of signal amplitude, to provide information of the characteristics of a large number of incremental areas between the boreholes. Such information is useable to produce a tomograph of the subsoil structure between the boreholes. By processing signals of relatively high frequencies, e.g., up to 100 Hz, and by closely spacing the geophones, a high resolution tomograph can be produced.

Narasimhan, K. Y.↗

Pulsed Multiple Reaction Monitoring Approach to Enhancing Sensitivity of a Tandem Quadrupole Mass Spectrometer

Liquid chromatography (LC)-triple quadrupole mass spectrometers operating in a Multiple Reaction Monitoring (MRM) mode are increasingly used for quantitative analysis of low abundance analytes in highly complex biochemical matrices. After development and selection of optimum MRM transition, sensitivity and data quality limitations are largely related to mass spectral peak interferences from sample or matrix constituents and statistical limitations at low number of ions reaching the detector. Herein, we report a new approach to enhancing MRM sensitivity by converting the continuous stream of ions from the ion source into a pulsed ion beam through the use of an Ion Funnel Trap (IFT). Evaluation of the pulsed MRM approach was performed with a tryptic digest of Shewanella oneidensis strain MR-1 spiked with several reference peptides. The sensitivity improvement observed with the IFT coupled to the triple quadrupole instrument is based on several unique features. First, ion accumulation in the radio frequency (RF) ion trap facilitates improved droplet desolvation, which is manifested in the reduced background ion noise at the detector. Second, signal amplitude for a given transition is enhanced because of an order-of-magnitude increase in the ion charge density per unit time compared to a continuous mode of operation. Third, signal detection at the full duty cycle is obtained, as the trap use eliminates dead times between transitions, which are inevitable with continuous ion streams. In comparison with the conventional approach, the pulsed MRM signals showed up to 5-fold enhanced peak amplitude and 2-3 fold reduced chemical background, resulting in an improvement in the limit of detection (LOD) by a factor of ~ 4 to ~ 8.

37 INORGANIC, ORGANIC, PHYSICAL, AND ANALYTICAL CH↗

DETECTION OF FAST TRANSIENTS WITH RADIO INTERFEROMETRIC ARRAYS

Next-generation radio arrays, including the Square Kilometre Array (SKA) and its pathfinders, will open up new avenues for exciting transient science at radio wavelengths. Their innovative designs, comprising a large number of small elements, pose several challenges in digital processing and optimal observing strategies. The Giant Metre-wave Radio Telescope (GMRT) presents an excellent test-bed for developing and validating suitable observing modes and strategies for transient experiments with future arrays. Here we describe the first phase of the ongoing development of a transient detection system for GMRT that is planned to eventually function in a commensal mode with other observing programs. It capitalizes on the GMRT's interferometric and sub-array capabilities, and the versatility of a new software backend. We outline considerations in the plan and design of transient exploration programs with interferometric arrays, and describe a pilot survey that was undertaken to aid in the development of algorithms and associated analysis software. This survey was conducted at 325 and 610 MHz, and covered 360 deg{sup 2} of the sky with short dwell times. It provides large volumes of real data that can be used to test the efficacies of various algorithms and observing strategies applicable for transient detection. We present examples that illustrate the methodologies of detecting short-duration transients, including the use of sub-arrays for higher resilience to spurious events of terrestrial origin, localization of candidate events via imaging, and the use of a phased array for improved signal detection and confirmation. In addition to demonstrating applications of interferometric arrays for fast transient exploration, our efforts mark important steps in the roadmap toward SKA-era science.

46 INSTRUMENTATION RELATED TO NUCLEAR SCIENCE AND ↗

Sers Imaging of Nasopharyngeal Carcinoma Markers Using an Antibody-Conjugated Gold Nanoparticles Probe

Surface-enhanced Raman scattering (SERS) nanotags as an ultrasensitive nanoprobe is becoming popular for the detection of biomarkers. Herein, antibody-conjugated gold nanoparticles (AuNPs) were used to target LMP2A in an LMP2A-infected CNE2 cell line. SERS maps showed that the LMP2A was distributed around the cell, which was consistent with the results of immunofl uorescence staining in the previous report. This location could be due to the specific binding of the bioconjugated nanotags to the receptors on the cell surface. However, the CNE2 cell line without LMP2A-infected showed no detectable signal at 1044 cm{sup –1}. The results demonstrated the potential feasibility of AuNPs nanotags as highly sensitive probes conjugated at the subcellular level for detection and localization of cancer markers in nasopharyngeal carcinoma (NPC).

77 NANOSCIENCE AND NANOTECHNOLOGY↗

Apparatus and method for determining the mass density of a filament

A method and apparatus for determining the mass density of a moving filament is provided. The method includes the steps of providing a filament across two supports, tensioning the filament, inducing a vibration into the filament segment between the supports, reinforcing the vibration using an amplified feedback signal, detecting the vibrational frequency data, processing the data using a fast-fourier transform analysis, and then displaying the frequency. The use of the feedback signal results in a self-tuning resonant loop. Open loop versions may also be used. The apparatus includes a base supporting a fixed support and a transducer which in turn supports a moveable support. The transducer vibrates the moveable support transversely to the direction of travel of the filament, thereby inducing a transverse vibrational mode. The output of the transducer is amplified and used to drive a second amplifier to produce a self-tuning resonant loop. In the open loop version a signal generator is used to drive the transducer through a frequency range, during which the amplitude peak is identified.

Hinkley, Jeffrey A.↗

Apparatus and Method for Determining the Mass Density of a Filament

A method and apparatus for determining the mass density of a moving filament is provided. The method includes the steps of providing a filament across two supports, tensioning the filament. inducing a vibration into the filament segment between the supports, reinforcing the vibration using an amplified feedback signal, detecting the vibrational frequency data. processing the data using a fast-fourier transform analysis. and then displaying the frequency. The use of the feedback signal results in a self-tuning resonant loop. Open loop versions may also be used. The apparatus includes a base supporting a fixed support and a transducer which in turn supports a moveable support. The transducer vibrates the moveable support transversely to the direction of travel of the filament, thereby inducing a transverse vibrational mode. The output of the transducer is amplified and used to drive a second amplifier to produce a self-tuning resonant loop. In the open loop version a signal generator is used to drive the transducer through a frequency range, during which the amplitude peak is identified.

Hinkley, Jeffrey A.↗

Conceptual Design Report for the I2 Instrumentation Experiment in ATRC

The US Department of Energy In-Pile Instrumentation (I2) program is tasked with developing advanced sensors for in-pile service as well as supporting the engineering required to implement existing nuclear sensor technologies in US high-power test reactors. The ATRC instrumentation test has been conceived to address both of these missions, specifically with respect to neutron flux measurements. Space has been allocated in the test for Self-Powered Neutron Detectors (SPNDs), fission chambers, and Micro-Pocket Fission Detectors (MPFDs). The real-time flux readings obtained from these instruments will be compared with time integrated data obtained from passive neutron dosimetry (i.e., “flux” wires). This work will be complementary to data obtained from the TREAT MIMIC-N experiment. This experiment is expected to support instrumentation efforts related to the proposed Medium-I loop and to instrumenting loop experiments conducted in the ATR center flux trap. While the MIMIC-N experiment was conducted in a dry environment, the ATRC I-19 experiment will be conducted in an aqueous environment, similar to the center flux trap loop experiments but will take place at ambient temperature and pressure, and at a much lower neutron flux. One of the challenges of the ATRC I-19 experiment will be low amplitude signals produced by the sensors in the low neutron fluxes of ATRC. However, related work conducted several years ago in ATRC was able to reliably detect signals using a similar instrument set.

46 INSTRUMENTATION RELATED TO NUCLEAR SCIENCE AND ↗

Verifying status of a termination end cap of a microinverter chain

A photovoltaic (PV) system includes a system control module that determines the presence of a microinverter chain termination end cap. The end cap includes an embedded circuit. The embedded circuit includes components having resistive, reactive, or impedance values. A signal source provides a signal through the microinverter chain. A parameter for a sensed signal detected by the system control module is used to determine the presence of the end cap using a change between the parameter for the sense signal and a reference parameter.

14 SOLAR ENERGY↗

Verifying status of a termination end cap of a microinverter chain

A photovoltaic (PV) system includes a system control module that determines the presence of a microinverter chain termination end cap. The end cap includes an embedded circuit. The embedded circuit includes components having resistive, reactive, or impedance values. A signal source provides a signal through the microinverter chain. A parameter for a sensed signal detected by the system control module is used to determine the presence of the end cap using a change between the parameter for the sense signal and a reference parameter.

Chapman, Patrick L.↗

Personnel Dose Assessment during Active Interrogation

A leading candidate in the detection of special nuclear material (SNM) is active interrogation (AI). Unlike passive interrogation, AI uses a source to enhance or create a detectable signal from SNM (usually fission), particularly in shielded scenarios or scenarios where the SNM has a low activity. The use of AI thus makes the detection of SNM easier or, in some scenarios, even enables previously impossible detection. During the development of AI sources, significant effort is put into determining the source strength required to detect SNM in specific scenarios. Usually during this process, but not always, an evaluation of personnel dose is also completed. In this instance personnel dose could involve any of the following: (1) personnel performing the AI; (2) unknown stowaways who are inside the object being interrogated; or (3) in clandestine interrogations, personnel who are known to be inside the object being interrogated but are unaware of the interrogation. In most instances, dose to anyone found smuggling SNM will be a secondary issue. However, for the organizations performing the AI, legal if not moral considerations should make dose to the personnel performing the AI, unknown stowaways, or innocent bystanders in clandestine interrogations a serious concern.

46 INSTRUMENTATION RELATED TO NUCLEAR SCIENCE AND ↗

Early Oscillation Detection Technique for Hybrid DC/DC Converters

Oscillation or instability is a situation that must be avoided for reliable hybrid DC/DC converters. A real-time electronics measurement technique was developed to detect catastrophic oscillations at early stages for hybrid DC/DC converters. It is capable of identifying low-level oscillation and determining the degree of the oscillation at a unique frequency for every individual model of the converters without disturbing their normal operations. This technique is specially developed for space-used hybrid DC/DC converters, but it is also suitable for most of commercial and military switching-mode power supplies. This is a weak-electronic-signal detection technique to detect hybrid DC/DC converter oscillation presented as a specific noise signal at power input pins. It is based on principles of feedback control loop oscillation and RF signal modulations, and is realized by using signal power spectral analysis. On the power spectrum, a channel power amplitude at characteristic frequency (CPcf) and a channel power amplitude at switching frequency (CPsw) are chosen as oscillation level indicators. If the converter is stable, the CPcf is a very small pulse and the CPsw is a larger, clear, single pulse. At early stage of oscillation, the CPcf increases to a certain level and the CPsw shows a small pair of sideband pulses around it. If the converter oscillates, the CPcf reaches to a higher level and the CPsw shows more high-level sideband pulses. A comprehensive stability index (CSI) is adopted as a quantitative measure to accurately assign a degree of stability to a specific DC/DC converter. The CSI is a ratio of normal and abnormal power spectral density, and can be calculated using specified and measured CPcf and CPsw data. The novel and unique feature of this technique is the use of power channel amplitudes at characteristic frequency and switching frequency to evaluate stability and identify oscillations at an early stage without interfering with a DC/DC converter s normal operation. This technique eliminates the probing problem of a gain/phase margin method by connecting the power input to a spectral analyzer. Therefore, it is able to evaluate stability for all kinds of hybrid DC/DC converters with or without remote sense pins, and is suitable for real-time and in-circuit testing. This frequency-domain technique is more sensitive to detect oscillation at early stage than the time-domain method using an oscilloscope.

Wang, Bright L.↗

Spatio-Temporal Signal Twice-Whitening Algorithms on the hx3100 Ultra-Low Power Multicore Processor

While modern signal detection theory fully accounts for spatially distributed sensors, exploiting these techniques for real-time sensing using large, underwater acoustic arrays requires advances in the spatio-temporal signal processing algorithms. In particular, the computational complexity of many spatio-temporal processing techniques is so large that conventional computer processors lack sufficient throughput to provide real-time processing of large spatio-temporal data sets. These limits are exacerbated when constraints, such as power consumption or footprint, reduce the available computational resources. In this report, we demonstrate an implementation of a signal twice-whitening algorithm that is better suited for processing spatio-temporal data in real time. We emphasize these advances by implementing data whitening on the Coherent Logix hx3100 processor, a programmable multicore processor intended for low-power and high-throughput signal processing. These results serve as an example of how the novel capabilities available from emerging multicore processor platforms can provide real-time, software-defined processing of large data sets acquired by spatially distributed sensing.

99 GENERAL AND MISCELLANEOUS↗

Ultrafast x-ray and electron scattering of free molecules: A comparative evaluation

Resolving gas phase molecular motions with simultaneous spatial and temporal resolution is rapidly coming within the reach of x-ray Free Electron Lasers (XFELs) and Mega-electron-Volt (MeV) electron beams. These two methods enable scattering experiments that have yielded fascinating new results, and while both are important methods for determining transient molecular structures in photochemical reactions, it is important to understand their relative merits. In the present study, we evaluate the respective scattering cross sections of the two methods and simulate their ability to determine excited state molecular structures in light of currently existing XFEL and MeV source parameters. Using the example of optically excited N-methyl morpholine and simulating the scattering patterns with shot noise, we find that the currently achievable signals are superior with x-ray scattering for equal samples and on a per-shot basis and that x-ray scattering requires fewer detected signal counts for an equal fidelity structure determination. Importantly, within the independent atom model, excellent structure determinations can be achieved for scattering vectors only to about 5 Å−1, leaving larger scattering vector ranges for investigating vibrational motions and wavepackets. Electron scattering has a comparatively higher sensitivity toward hydrogen atoms, which may point to applications where electron scattering is inherently the preferred choice, provided that excellent signals can be achieved at large scattering angles that are currently difficult to access.

74 ATOMIC AND MOLECULAR PHYSICS↗

High-resolution absolute frequency referenced fiber optic sensor for quasi-static strain sensing

We present a quasi-static fiber optic strain sensing system capable of resolving signals below nanostrain from 20 mHz. A telecom-grade distributed feedback CW diode laser is locked to a fiber Fabry-Perot sensor, transferring the detected signals onto the laser. An H{sup 13}C{sup 14}N absorption line is then used as a frequency reference to extract accurate low-frequency strain signals from the locked system.

71 CLASSICAL AND QUANTUM MECHANICS, GENERAL PHYSIC↗

SNM Radiation Signature Classification Using Different Semi-Supervised Machine Learning Models

The timely detection of special nuclear material (SNM) transfers between nuclear facilities is an important monitoring objective in nuclear nonproliferation. Persistent monitoring enabled by successful detection and characterization of radiological material movements could greatly enhance the nuclear nonproliferation mission in a range of applications. Supervised machine learning can be used to signal detections when material is present if a model is trained on sufficient volumes of labeled measurements. However, the nuclear monitoring data needed to train robust machine learning models can be costly to label since radiation spectra may require strict scrutiny for characterization. Therefore, this work investigates the application of semi-supervised learning to utilize both labeled and unlabeled data. As a demonstration experiment, radiation measurements from sodium iodide (NaI) detectors are provided by the Multi-Informatics for Nuclear Operating Scenarios (MINOS) venture at Oak Ridge National Laboratory (ORNL) as sample data. Anomalous measurements are identified using a method of statistical hypothesis testing. After background estimation, an energy-dependent spectroscopic analysis is used to characterize an anomaly based on its radiation signatures. In the absence of ground-truth information, a labeling heuristic provides data necessary for training and testing machine learning models. Supervised logistic regression serves as a baseline to compare three semi-supervised machine learning models: co-training, label propagation, and a convolutional neural network (CNN). In each case, the semi-supervised models outperform logistic regression, suggesting that unlabeled data can be valuable when training and demonstrating value in semi-supervised nonproliferation implementations.

98 NUCLEAR DISARMAMENT, SAFEGUARDS, AND PHYSICAL P↗

Goldstone field test activities: Target search

In March of this year prototype SETI equipment was installed at DSS13, the 26 meter research and development antenna at NASA's Goldstone complex of satellite tracking dishes. The SETI equipment will remain at this site at least through the end of the summer so that the hardware and software developed for signal detection and recognition can be fully tested in a dynamic observatory environment. The field tests are expected to help understand which strategies for observing and which signal recognition algorithms perform best in the presence of strong man-made interfering signals (RFI) and natural astronomical sources.

Tarter, J.↗

Micro-Bunched Beam Production at FAST for Narrow Band THz Generation Using a Slit-Mask

We discuss simulations and experiments on creating micro-bunch beams for generating narrow band THz radiation at the Fermilab Accelerator Science and Technology (FAST) facility. The low-energy electron beamline at FAST consists of a photoinjector-based RF gun, two Lband superconducting accelerating cavities, a chicane, and a beam dump. The electron bunches are lengthened with cavity phases set off-crest for better longitudinal separation and then micro-bunched with a slit-mask installed in the chicane. We carried out the experiments with 30 MeV electron beams and detected signals of the micro-bunching using a skew quadrupole magnet in the chicane. In this paper, the details of micro-bunch beam production, the detection of micro-bunching and comparison with simulations are described.

Hyun, J.↗