Engineering Papers⌕ Search

SEARCH · Engineering Papers

Results for “SYSTEM MONITORING”

Search indexed NASA NTRS and DOE OSTI research on propulsion, heat transfer, battery materials and energy systems. Follow report and document links to the original sources.

Quote a phrase for an exact phrase match. Source license links do not imply unrestricted reuse.

At least 433 records · Page 24

Possible impacts of molten salt reactors on the International Monitoring System

Molten salt reactors (MSRs) are gaining support as many countries look for ways to increase power generation and replace aging nuclear energy production facilities. MSRs have inherently safe designs, are scalable in size, can burn transuranic wastes from traditional solid fuel nuclear reactors, can store excess heat in thermal reservoirs for water desalination, and can be used to produce medical isotopes as part of the real-time liquid-fuel recycling process. The ability to remove 135 Xe in real time from the fuel improves the power production in an MSR because 135 Xe is the most significant neutron-absorbing isotope generated by nuclear fission. Xenon-135, and other radioactive gases, are removed by sparging the fuel with an inert gas while the liquid fuel is recirculated from the reactor inner core through the heat exchangers. Without effective abatement technologies, large amounts of radioactive gas could be released during the sparging process. This work examines the potential impact of radioxenon releases on samplers used by the International Monitoring System (IMS) to detect nuclear explosions. Here, atmospheric transport simulations from seven hypothetical MSRs on different continents were used to evaluate the holdup time needed before release of radioxenon so IMS samplers would register few detections. Abatement technologies that retain radioxenon isotopes for at least 120 d before their release will be needed to mitigate the impacts from a molten salt breeder reactor used to replace a nuclear power plant. A holdup time of about 150 d is needed to reduce emissions to the average level of current nuclear power plants.

98 NUCLEAR DISARMAMENT, SAFEGUARDS, AND PHYSICAL P↗

REAL TIME ULTRASONIC ALUMINUM SPOT WELD MONITORING SYSTEM

Aluminum alloys pose several properties that make them one of the most popular engineering materials: they have excellent corrosion resistance, and high weight-to-strength ratio. Resistance spot welding of aluminum alloys is widely used today but oxide film and aluminum thermal and electrical properties make spot welding a difficult task. Electrode degradation due to pitting, alloying and mushrooming decreases the weld quality and adjustment of parameters like current and force is required. To realize these adjustments and ensure weld quality, a tool to measure weld quality in real time is required. In this paper, a real time ultrasonic non-destructive evaluation system for aluminum spot welds is presented. The system is able to monitor nugget growth while the spot weld is being made. This is achieved by interpreting the echoes of an ultrasound transducer located in one of the welding electrodes. The transducer receives and transmits an ultrasound signal at different times during the welding cycle. Valuable information of the weld quality is embedded in this signal. The system is able to determine the weld nugget diameter by measuring the delays of the ultrasound signals received during the complete welding cycle. The article presents the system performance on aluminum alloy AA6022.

36 MATERIALS SCIENCE↗

Passive, Direct-Read Monitoring System for Selective Detection and Quantification of Hydrogen Chloride

Monitoring the exposure of an employee to hydrogen chloride or hydrochloric acid in the presence of other acids has been a challenge to the industrial hygiene community. The capability of a device to differentiate the levels of acid vapors would allow for more accurate determinations of exposure and therefore improved occupational health. In this work, a selective direct-read colorimetric badge system was validated for Short Term Exposure Limit (STEL) monitoring of hydrogen chloride. The passive colorimetric badge system consists of a direct reading badge and a color scale. The badge has a coated indicator layer with a diffusive resistance in the shape of an exclamation mark. An exclamation mark will appear if hydrogen chloride is present in the atmosphere at concentrations at or above 2.0 ppm. By using the color scale, the intensity of the color formed on the badge can be further quantified up to 25 ppm. The system was validated according to a protocol based on the NIOSH Protocol for the Evaluation of Passive Monitors. The badge was exposed to relative humidities ranging from 11% to 92%, temperatures ranging from 7 C to 400 C and air velocities ranging from 5 cm/sec to 170 cm/sec. All experiments were conducted in a laboratory vapor generation system. Hydrofluoric acid, nitric acid, sulfuric acid, chlorine, hydrogen sulfide and organic acids showed no effect on the performance of the hydrogen chloride monitoring system. The passive badge and color scale system exceeded the accuracy requirements as defined by NIOSH. At ambient conditions, the mean coefficient of variation was 10.86 and the mean bias was 1.3%. This data was presented previously at the American Industrial Hygiene Conference and Exposition in Toronto, Canada in June 1999.

Chapman, K. B.↗

Prototype development and test results of a continuous ambient air monitoring system for hydrazine at the 10 ppb level

A Hydrazine Vapor Area Monitor (HVAM) system is currently being field tested as a detector for the presence of hydrazine in ambient air. The MDA/Polymetron Hydrazine Analyzer has been incorporated within the HVAM system as the core detector. This analyzer is a three-electrode liquid analyzer typically used in boiler feed water applications. The HVAM system incorporates a dual-phase sample collection/transport method which simultaneously pulls ambient air samples containing hydrazine and a very dilute sulfuric acid solution (0.0001 M) down a length of 1/4 inch outside diameter (OD) tubing from a remote site to the analyzer. The hydrazine-laden dilute acid stream is separated from the air and the pH is adjusted by addition of a dilute caustic solution to a pH greater than 10.2 prior to analysis. Both the dilute acid and caustic used by the HVAM are continuously generated during system operation on an "as needed" basis by mixing a metered amount of concentrated acid/base with dilution water. All of the waste water generated by the analyzer is purified for reuse by Barnstead ion-exchange cartridges so that the entire system minimizes the generation of waste materials. The pumping of all liquid streams and mixing of the caustic solution and dilution water with the incoming sample are done by a single pump motor fitted with the appropriate mix of peristaltic pump heads. The signal to noise (S/N) ratio of the analyzer has been enhanced by adding a stirrer in the MDA liquid cell to provide mixing normally generated by the high liquid flow rate designed by the manufacturer. An onboard microprocessor continuously monitors liquid levels, sample vacuum, and liquid leak sensors, as well as handles communications and other system functions (such as shut down should system malfunctions or errors occur). The overall system response of the HVAM can be automatically checked at regular intervals by measuring the analyzer response to a metered amount of calibration standard injected into the dilute acid stream. The HVAM system provides two measurement ranges (threshold limit value (TLV): 10 to 1000 parts per billion (ppb)/LEAK: 100 ppb to 10 parts per million (ppm)). The LEAK range is created by dilution of the sulfuric acid/hydrazine liquid sample with pure water. This dual range capability permits the analyzer to quantify ambient air samples whose hydrazine concentrations range from 10 ppb to as high as 10 ppm. The laboratory and field prototypes have demonstrated total system response times on the order of 10 to 12 minutes for samples ranging from 10 to 900 ppb in the lLV mode and is greater than 2 minutes for samples ranging from 100 to 1300 ppb in the LEAK mode. Service intervals of over 3 months have been demonstrated for continuous 24 hour/day, 7 day/week usage. The HVAM is made up of a purged cabinet that contains power supplies, RS422 signal transmission capabilities, a UPS, an on-site warning system, and a Line Replaceable Unit (LRU). The LRU includes all of the liquid flow system, the analyzer, the control/data system microprocessor and assorted flow and liquid-level sensors. The LRU is mounted on a track slide system so it can be serviced inplace or totally removed and quickly exchanged with another calibrated unit, thus minimizing analyzer downtime. Once an LRU is removed from an analyzer enclosure, it can be brought to a laboratory facility for complete calibration and periodic maintenance.

Meneghelli, Barry↗

Physics Simulation Software for Autonomous Propellant Loading and Gas House Autonomous System Monitoring

1. Kennedy Space Center (KSC) is developing a mobile launching system with autonomous propellant loading capabilities for liquid-fueled rockets. An autonomous system will be responsible for monitoring and controlling the storage, loading and transferring of cryogenic propellants. The Physics Simulation Software will reproduce the sensor data seen during the delivery of cryogenic fluids including valve positions, pressures, temperatures and flow rates. The simulator will provide insight into the functionality of the propellant systems and demonstrate the effects of potential faults. This will provide verification of the communications protocols and the autonomous system control. 2. The High Pressure Gas Facility (HPGF) stores and distributes hydrogen, nitrogen, helium and high pressure air. The hydrogen and nitrogen are stored in cryogenic liquid state. The cryogenic fluids pose several hazards to operators and the storage and transfer equipment. Constant monitoring of pressures, temperatures and flow rates are required in order to maintain the safety of personnel and equipment during the handling and storage of these commodities. The Gas House Autonomous System Monitoring software will be responsible for constantly observing and recording sensor data, identifying and predicting faults and relaying hazard and operational information to the operators.

Regalado Reyes, Bjorn Constant↗

Measurement of the Tracer Gradient and Sampling System Bias of the Hot Fuel Examination Facility Stack Air Monitoring System

This report describes tracer gas uniformity and bias measurements made in the exhaust air discharge of the Hot Fuel Examination Facility at Idaho National Laboratory. The measurements were a follow-up on earlier measurements which indicated a lack of mixing of the two ventilation streams being discharged via a common stack. The lack of mixing is detrimental to the accuracy of air emission measurements. The lack of mixing was confirmed in these new measurements. The air sampling probe was found to be out of alignment and that was corrected. The suspected sampling bias in the air sample stream was disproved.

21 SPECIFIC NUCLEAR REACTORS AND ASSOCIATED PLANTS↗

A three-axis angular monitoring system for the magnetic field satellite /MAGSAT/ mission

An electro-optical attitude transfer system was developed to monitor the angular orientation of magnetometers deployed at the end of a 20-foot boom extending outboard from the Magsat spacecraft. One autocollimator monitors pitch and yaw attitude, cooperating with a plane mirror at the end of the boom; a second monitors roll (twist) from an offset look-angle, using one dihedral reflector at the boom end and a second on the spacecraft. RMS errors due to all causes including linearity, G-forces, cross-coupling and translation are estimated to be 3.9 arcsec over + or - 180 arcsec excursion in pitch and yaw, and 5.3 to 7.5 arcsec over + or - 300 arcsec roll. Design and fabrication problems relative to the remote dihedral refector proved to be the most challenging, and solutions to these problems will be described.

Collyer, P. W.↗

TECHNOLOGY GOALS FOR A NEXT GENERATION RADIOXENON MONITORING SYSTEM

The Swedish Automated/Unattended Noble Gas Analyzer (SAUNA) is a nuclear explosion monitoring technology that was developed to provide continuous field measurement of radioxenon gas escaping from an underground nuclear detonation. This capability is a key to the verification of the Comprehensive nuclear Test Ban Treaty (CTBT). While the SAUNA technology has demonstrated success in the field, a decade of operation primarily in the International Noble Gas Experiment (INGE) has yielded areas for improvement in operations and verification. These opportunities include measurement sensitivity, sample throughput time, system uptime, and data availability. Increasing measurement sensitivity allows for finer discrimination between manmade radioxenon signals (from sources such as medical isotope production facilities) and radioxenon signals that result from fission in a nuclear weapon. Measurement sensitivity can be increased with techniques such as halving the sample processing time or increasing the quantity of xenon extracted from the atmosphere. Additionally, improvements in gas processing technology and control system software can improve the uptime and data availability. This paper will discuss the technical requirements as well as the system and operational specifications which we expect to be the groundwork for the next-generation of radioxenon monitoring systems.

Ely, James H.↗

Monitoring System for Storm Readiness and Recovery of Test Facilities: Integrated System Health Management (ISHM) Approach

Severe weather events are likely occurrences on the Mississippi Gulf Coast. It is important to rapidly diagnose and mitigate the effects of storms on Stennis Space Center's rocket engine test complex to avoid delays to critical test article programs, reduce costs, and maintain safety. An Integrated Systems Health Management (ISHM) approach and technologies are employed to integrate environmental (weather) monitoring, structural modeling, and the suite of available facility instrumentation to provide information for readiness before storms, rapid initial damage assessment to guide mitigation planning, and then support on-going assurance as repairs are effected and finally support recertification. The system is denominated Katrina Storm Monitoring System (KStorMS). Integrated Systems Health Management (ISHM) describes a comprehensive set of capabilities that provide insight into the behavior the health of a system. Knowing the status of a system allows decision makers to effectively plan and execute their mission. For example, early insight into component degradation and impending failures provides more time to develop work around strategies and more effectively plan for maintenance. Failures of system elements generally occur over time. Information extracted from sensor data, combined with system-wide knowledge bases and methods for information extraction and fusion, inference, and decision making, can be used to detect incipient failures. If failures do occur, it is critical to detect and isolate them, and suggest an appropriate course of action. ISHM enables determining the condition (health) of every element in a complex system-of-systems or SoS (detect anomalies, diagnose causes, predict future anomalies), and provide data, information, and knowledge (DIaK) to control systems for safe and effective operation. ISHM capability is achieved by using a wide range of technologies that enable anomaly detection, diagnostics, prognostics, and advise for control: (1) anomaly detection algorithms and strategies, (2) fusion of DIaK for anomaly detection (model-based, numerical, statistical, empirical, expert-based, qualitative, etc.), (3) diagnostics/prognostics strategies and methods, (4) user interface, (5) advanced control strategies, (6) integration architectures/frameworks, (7) embedding of intelligence. Many of these technologies are mature, and they are being used in the KStorMS. The paper will describe the design, implementation, and operation of the KStorMS; and discuss further evolution to support other needs such as condition-based maintenance (CBM).

Figueroa, Fernando↗

Production Application Performance Data Streaming for System Monitoring

In this article, we present an approach to streaming collection of application performance data. Practical application performance tuning and troubleshooting in production high-performance computing (HPC) environments requires an understanding of how applications interact with the platform, including (but not limited to) parallel programming libraries such as Message Passing Interface (MPI). Several profiling and tracing tools exist that collect heavy runtime data traces either in memory (released only at application exit) or on a file system (imposing an I/O load that may interfere with the performance being measured). Although these approaches are beneficial in development stages and post-run analysis, a systemwide and low-overhead method is required to monitor deployed applications continuously. This method must be able to collect information at both the application and system levels to yield a complete performance picture. In our approach, an application profiler collects application event counters. A sampler uses an efficient inter-process communication method to periodically extract the application counters and stream them into an infrastructure for performance data collection. We implement a tool-set based on our approach and integrate it with the Lightweight Distributed Metric Service (LDMS) system, a monitoring system used on large-scale computational platforms. LDMS provides the infrastructure to create and gather streams of performance data in a low overhead manner. We demonstrate our approach using applications implemented with MPI, as it is one of the most common standards for the development of large-scale scientific applications. We utilize our tool-set to study the impact of our approach on an open source HPC application, Nalu. Our tool-set enables us to efficiently identify patterns in the behavior of the application without source-level knowledge. We leverage LDMS to collect system-level performance data and explore the correlation between the system and application events. Finally, we demonstrate how our tool-set can help detect anomalies with a low latency. We run tests on two different architectures: a system enabled with Intel Xeon Phi and another system equipped with Intel Xeon processor. Our overhead study shows our method imposes at most 0.5% CPU usage overhead on the application in realistic deployment scenarios.

59 BASIC BIOLOGICAL SCIENCES↗

TV fatigue crack monitoring system

An apparatus is disclosed for monitoring the development and growth of fatigue cracks in a test specimen subjected to a pulsating tensile load. A plurality of television cameras photograph a test specimen which is illuminated at the point of maximum tensile stress. The television cameras have a modified vidicon tube which has an increased persistence time thereby eliminating flicker in the displayed images.

Exton, R. J.↗

Indicators and Monitoring Systems for Urban Climate Resiliency

Cities in the USA and around the world have begun to take an active role in responding to climate change. A central requirement for effective urban climate strategies is the capacity to understand and measure how the climate is changing, the physical, environmental, and social impacts of the changes, and whether adaptation and resiliency policies and programs put in place in response are working. The objective of this paper is to review and assess how urban climate change and resiliency efforts can be measured and to define what might serve as meaningful indicator and monitoring protocols. The New York City Panel on Climate Change (NPCC) is used as a case study along with a reviews of the emerging literature of urban climate change indicators to analyze the requirements and processes needed for a successful urban climate resiliency indicator and monitoring (I and M) system. In the paper, the basic requirements of a proposed Urban Climate Resilience Indicators and Monitoring System are presented. A specific illustration of an I and M system for tracking the urban heat island highlights challenges as well as potential solutions embedded within such systems. Discussions how these protocols can be translated to other locales and settings, as well as the relationship to the US National Climate Assessment indicator process, are presented.

New York City Panel on Climate Change↗

Prognostic Health Monitoring System: Component Selection Based on Risk Criteria and Economic Benefit Assessment

Prognostic health monitoring (PHM) is a proactive approach to monitor the ability of structures, systems, and components (SSCs) to withstand structural, thermal, and chemical loadings over the SSCs planned service lifespans. The current efforts to extend the operational license lifetime of the aging fleet of U.S. nuclear power plants from 40 to 60 years and beyond can benefit from a systematic application of PHM technology. Implementing a PHM system would strengthen the safety of nuclear power plants, reduce plant outage time, and reduce operation and maintenance costs. However, a nuclear power plant has thousands of SSCs, so implementing a PHM system that covers all SSCs requires careful planning and prioritization. This paper therefore focuses on a component selection that is based on the analysis of a component's failure probability, risk, and cost. Ultimately, the decision on component selection depend on the overall economical benefits arising from safety and operational considerations associated with implementing the PHM system.

22 GENERAL STUDIES OF NUCLEAR REACTORS↗

A Scalable Online Monitoring System Based on Elasticsearch for Distributed Data Acquisition in Cms

The part of the CMS Data Acquisition (DAQ) system responsible for data readout and event building is a complex network of interdependent distributed applications. To ensure successful data taking, these programs have to be constantly monitored in order to facilitate the timeliness of necessary corrections in case of any deviation from specified behaviour. A large number of diverse monitoring data samples are periodically collected from multiple sources across the network. Monitoring data are kept in memory for online operations and optionally stored on disk for post-mortem analysis. We present a generic, reusable solution based on an open source NoSQL database, Elasticsearch, which is fully compatible and non-intrusive with respect to the existing system. The motivation is to benefit from an off the-shelf software to facilitate the development, maintenance and support efforts. Elasticsearch provides failover and data redundancy capabilities as well as a programming language independent JSON-over-HTTP interface. The possibility of horizontal scaling matches the requirements of a DAQ monitoring system. The data load from all sources is balanced by redistribution over an Elasticsearch cluster that can be hosted on a computer cloud. In order to achieve the necessary robustness and to validate the scalability of the approach the above monitoring solution currently runs in parallel with an existing in-house developed DAQ monitoring system.

46 INSTRUMENTATION RELATED TO NUCLEAR SCIENCE AND ↗

Multi-level Simulation of a Real Time Vibration Monitoring System Component

This paper describes the development of a custom built Digital Signal Processing (DSP) printed circuit board designed to implement the Advanced Real Time Vibration Monitoring Subsystem proposed by MSFC Transportation Directorate in 2000 for the Space Shuttle Main Engine Advanced Health Management System (AHMS). This Real Time Vibration Monitoring System (RTVMS) is being developed for ground use as part of the AHMS Health Management Computer-Integrated Rack Assembly (HMC-IRA). The HMC-IRA RTVMS design contains five DSPs which are highly interconnected through individual communication ports, shared memory, and a unique communication router that allows all the DSPs to receive digitized data from two multi-channel analog boards simultaneously. This paper will briefly cover the overall board design but will focus primarily on the state-of-the-art simulation environment within which this board was developed. This 16-layer board with over 1800 components and an additional mezzanine card has been an extremely challenging design. Utilization of a Mentor Graphics simulation environment provided the unique board and system level simulation capability to ascertain any timing or functional concerns before production. By combining VHDL, Synopsys Software and Hardware Models, and the Mentor Design Capture Environment, multiple simulations were developed to verify the RTVMS design. This multi-level simulation allowed the designers to achieve complete operability without error the first time the RTVMS printed circuit board was powered. The HMCIRA design has completed all engineering unit testing and the deliverable unit is currently under development.

Roberston, Bryan↗

Advanced Fiber-optic Monitoring System for Space-flight Applications

Researchers at Luna Innovations Inc. and the National Aeronautic and Space Administration s Marshall Space Flight Center (NASA MSFC) have developed an integrated fiber-optic sensor system for real-time monitoring of chemical contaminants and whole-cell bacterial pathogens in water. The system integrates interferometric and evanescent-wave optical fiber-based sensing methodologies with atomic force microscopy (AFM) and long-period grating (LPG) technology to provide versatile measurement capability for both micro- and nano-scale analytes. Sensors can be multiplexed in an array format and embedded in a totally self-contained laboratory card for use with an automated microfluidics platform.

Hull, M. S.↗