Engineering Papers⌕ Search

SEARCH · Engineering Papers

Results for “SPECTROMETERS”

Search indexed NASA NTRS and DOE OSTI research on propulsion, heat transfer, battery materials and energy systems. Follow report and document links to the original sources.

Quote a phrase for an exact phrase match. Source license links do not imply unrestricted reuse.

At least 433 records · Page 24

Data-Driven Performance Optimization of Gamma Spectrometers With Many Channels

In gamma spectrometers with variable spectroscopic performance across many channels (e.g., many pixels or voxels), a tradeoff exists between including data from successively worse-performing readout channels and increasing efficiency. Brute-force calculation of the optimal set of included channels is exponentially infeasible as the number of channels grows, and approximate methods are required. In this work, we present a data-driven framework for attempting to find near-optimal sets of included detector channels. The framework leverages non-negative matrix factorization (NMF) to learn the behavior of gamma spectra across the detector and clusters similarly-performing detector channels together. Performance comparisons are then made between spectra with channel clusters removed, which is more feasible than brute force. The framework is general and can be applied to arbitrary, user-defined performance metrics depending on the application. We apply this framework to optimizing gamma spectra measured by H3D M400 CdZnTe (CZT) spectrometers, which exhibit variable performance across their crystal volumes. In particular, we show several examples optimizing various performance metrics for uranium and plutonium gamma spectra in non-destructive assay (NDA) for nuclear safeguards, and explore trends in performance versus parameters such as clustering algorithm type. We also compare the NMF + clustering pipeline to several non-machine-learning (ML) algorithms, including several greedy algorithms. Although, we find that the NMF + clustering pipeline tends to find the best-performing set of detector voxels, significantly improving over the unoptimized spectra, but that a greedy accumulation of spectra segmented by detector depth can, in some cases, give similar performance improvements in much less computation time.

Energy resolution↗

Absolute timing calibration of the Resolve microcalorimeter spectrometer on the X-ray Imaging and Spectroscopy Mission

The Resolve microcalorimeter spectrometer on the X-ray Imaging and Spectroscopy Mission (XRISM) is designed to have a good timing capability with the mission-level requirement of 1 ms as the absolute time tagging accuracy to suffice the needs for observatory science. In the ground calibration campaign, the absolute and relative timing offsets were measured using pulsed X-rays from the modulated X-ray sources. These offsets were used to determine calibration parameters, the Resolve timing coefficients, which are used in the offline correction of event times. In the orbit, reevaluation of the timing coefficients was carried out using the Crab pulsar, which was observed in two periods, one in the performance verification phase and the other in the guest observation phase. We report the absolute timing calibration of XRISM/Resolve using the ground and in-orbit data. Although the requirement is likely satisfied with the ground parameters, the timing coefficients have been refined using the in-orbit calibration to improve the timing accuracy. In addition, for the first time, we present the interpretation of the absolute timing offset originating from the analog and digital processing of X-ray events unique to a microcalorimeter spectrometer and present a complete view of the timing error of the Resolve instrument.

Astronomy and AstroPhysics↗

Energy gain scale calibration of the XRISM Resolve microcalorimeter spectrometer: ground calibration results and on-orbit comparison

The Resolve instrument aboard the X-ray Imaging and Spectroscopy Mission (XRISM) is a 36-pixel microcalorimeter spectrometer that provides nondispersive spectroscopy with ∼ 5 eV spectral resolution in the soft X-ray waveband. Resolve has a requirement to provide an absolute energy-scale calibration of ± 2 eV from 0.3 to 12 keV. We describe our ground calibration strategy and results of a subset of the ground calibration campaigns, including a discussion of improvements in the energy scale ground calibration compared with Hitomi’s. These improvements include calibration of the low-energy band below 4 keV with the instrument in the flight dewar and the dewar aperture door open, which was not performed for Hitomi, and thorough measurements over an extended high-energy waveband to 22 keV. We also developed an improved technique for gain calibration of “mid-res” secondary events, which have suppressed gain due to proximity to a preceding X-ray event (18 to 70 ms) on the same pixel. We provide a discussion of the on-orbit energy scale monitoring campaigns and an assessment of the Resolve energy scale uncertainties, a key parameter for astrophysics analysis. Energy-scale calibration approaches for future space-based instruments, including the X-ray Integral Field Unit on Athena and microcalorimeter spectrometers proposed or under discussion for future X-ray observatory concepts, have heritage in the calibration of XRISM. We briefly comment on lessons learned from Resolve calibration that are relevant for these future instruments.

Aluminum↗

Pre- and post-launch operation of the Resolve soft X-ray spectrometer onboard the XRISM satellite

Resolve is a high-resolution X-ray spectrometer onboard the X-Ray Imaging and Spectroscopy Mission (XRISM), launched on September 6 (UT), 2023. The Resolve has performed better than its required spectral resolution (7 eV at full width at half maximum at 6 keV), both on the ground and in orbit, and has been confirmed to have comparable performance to the soft X-ray spectrometer onboard the ASTRO-H (Hitomi) satellite. The focal plane is composed of an array of microcalorimeter detectors operated at 50 mK to achieve the required energy resolution, and the cooling system is designed to satisfy the lifetime requirement of over 3 years. The focal plane and cooling system are contained in a vacuum-insulated dewar. The cooling system is equipped with a two-stage adiabatic demagnetization refrigerator (ADR) that uses superfluid liquid helium (LHe) as its heat sink. The system includes a third ADR stage that can be used to provide the heat sink when the helium is exhausted. A Joule–Thomson cooler and several two-stage Stirling coolers are used to reduce the heat load on the LHe. During pre-launch operations, we carried out a superfluid LHe top-off operation. The resultant amount of LHe onboard Resolve was over 35 L before launch, which is sufficient to meet the lifetime requirement. During post-launch operation, the LHe vent valve was opened 5 min after launch during rocket acceleration, and the cryocoolers were turned on after several orbits, as planned, which established stable cooling within the dewar. Pre- and post-launch operations for the Resolve instrument were planned around multiple constraints from launch vehicle operations; all were successfully completed, and the launch requirements were fully met.

X-Ray Imaging and Spectroscopy Mission↗

High-precision monitoring of outgassing species in model extreme ultraviolet photoresists with a cavity ring-down spectrometer

Background Extreme ultraviolet (EUV) photoresists play a pivotal role in advancing nanopatterning technologies by balancing image quality and sensitivity. The outgassing behavior of photoresist thin films under EUV and deep ultraviolet (DUV) exposure reveals chemical details relevant to their performance. Aim Here, we focus on utilizing an analytical technique not previously used in photolithography, the tabletop cavity ring-down spectrometer, to investigate outgassing dynamics in EUV photoresists, enabling precise chemical identification and deeper insights into resist processing. Approach The spectrometer’s enhanced laser path length (∼ 20 km) and broadband absorption capabilities in the C–H overtone region allow for sensitive and temporally resolved detection of mixtures of outgassed species. Using a model resist comprising a polymer matrix with a photoacid generator and quencher, we analyzed the influence of time delays between exposure and post-exposure bake (PEB) as well as storage under varying environmental conditions. Results Suppression of isobutylene outgassing and thickness loss was observed with extended delays between exposure and PEB, potentially linked to water absorption and acid deactivation. The technique proved highly effective in distinguishing subtle chemical differences between processing stages. Conclusions Delay times and their environmental conditions, particularly humidity, reduce outgassing and thickness loss of photoresists during PEB, suggesting decreased acid-driven deprotection. This can potentially impact sensitivity, defectivity, and roughness of resist patterns, necessitating precise monitoring and control.

Extreme ultraviolet photoresists↗

High precision monitoring of outgassing species in model EUV photoresists with a cavity ring-down spectrometer

Extreme ultraviolet (EUV) photoresists play a pivotal role in advancing nanopatterning technologies by balancing image quality and sensitivity. The outgassing behavior of photoresist thin films under EUV and deep ultraviolet (DUV) exposure reveals chemical details relevant to their performance. This study focuses on utilizing an analytical technique not previously used in photolithography, the tabletop cavity ring-down spectrometer, to investigate outgassing dynamics in EUV photoresists, enabling precise chemical identification and deeper insights into resist processing. The spectrometer’s enhanced laser path length (~20 km) and broadband absorption capabilities in the CH overtone region allow for sensitive and temporally resolved detection of outgassed species. Using a model resist comprising a polymer matrix with a photoacid generator and quencher, we analyzed the influence of time delays between exposure and Post-Exposure Bake (PEB) as well as storage under varying environmental conditions. Suppression of isobutylene outgassing and thickness loss was observed with extended delays between exposure and PEB, potentially linked to water absorption and acid deactivation. The technique proved highly effective in distinguishing subtle chemical differences between processing stages. Delay times and their environmental conditions, particularly humidity, reduce outgassing and thickness loss of photoresists during PEB, suggesting decreased acid-driven deprotection. This can potentially impact sensitivity, defectivity, and roughness of resist patterns, necessitating precise monitoring and control.

Lüttgenau, Bernhard↗

Alignment of the Alpha Magnetic Spectrometer (AMS) in space

Abstract The Alpha Magnetic Spectrometer (AMS) is a precision particle physics detector operating at an altitude of $$\sim 410$$ ∼ 410 km aboard the International Space Station. The AMS silicon tracker, together with the permanent magnet, measures the rigidity (momentum/charge) of cosmic rays in the range from $$\sim 0.5$$ ∼ 0.5 GV to several TV. In order to have accurate rigidity measurements, the positions of more than 2000 tracker modules have to be determined at the micron level by an alignment procedure. The tracker was first aligned using the 400 GeV/c proton test beam at CERN and then re-aligned using cosmic-ray events after being launched into space. A unique method to align the permanent magnetic spectrometer for a space experiment is presented. The developed underlying mathematical algorithm is discussed in detail.

47 OTHER INSTRUMENTATION↗

Sagittally focusing X-ray spectrometer in asymmetric Laue geometry

A sagittally focusing transmission-diffraction X-ray spectrometer is proposed. Sagittal focusing is achieved using an asymmetric Laue reflection. The shape of the crystal is constructed to achieve sagittal focusing of the X-ray spectrum into a line on a flat detector pointed at the crystal. Here, we show that the resulting X-ray flux (photons/area) delivered to the detector can be greater by more than two orders of magnitude compared to that of a sagittally flat Laue spectrometer.

Webster, Lucas G. [University of New Mexico, Albuq↗

Chirped-grating spectrometer-on-a-chip

We demonstrate an on-chip spectrometer readily integrable with CMOS electronics. The structure is comprised of a SiO 2 /Si 3 N 4 /SiO 2 waveguide atop a silicon substrate. A transversely chirped grating is fabricated, in a single-step optical lithography process, on a portion of the waveguide to provide angle and wavelength dependent coupling to the guided mode. The spectral and angular information is encoded in the spatial dependence of the grating period. A uniform pitch grating area, separated from the collection area by an unpatterned propagation region, provides the out-coupling to a CMOS detector array. A resolution of 0.3 nm at 633 nm with a spectral coverage tunable across the visible and NIR (to ∼ 1 µm limited by the Si photodetector) by changing the angle of incidence, is demonstrated without the need for any signal processing deconvolution. This on-chip spectrometer concept will cost effectively enable a broad range of applications that are beyond the reach of current integrated spectroscopic technologies.

Nezhadbadeh, Shima↗

Spectrometer-free quantitative vapor sensing and classification via spatiotemporal imaging of porous silicon metasurfaces

Metasurfaces offer a compact platform for optical vapor sensing, but their practical deployment has been limited by weak evanescent light–matter interactions and reliance on spectrally resolved instrumentation. Here, we report porous silicon (pSi) metasurfaces for spectrometer-free quantitative detection of volatile organic compounds (VOCs) with strongly enhanced light–matter interaction. The engineered porosity increases sensitivity by >100× relative to non-porous dielectric metasurfaces, enabling limits of detection of 1.65 ppm for methanol and 9.1 ppm for ethanol across a broad dynamic range (<10 ppm to >103 ppm). Imaging-based readout provides a lightweight, spectrometer-free pathway for real-time quantitative sensing. Beyond quantitative detection, the mesoporous architecture introduces adsorption–desorption kinetics as an additional information channel. Analysis of the resulting spatiotemporal signatures enables kinetic fingerprinting without reliance on infrared spectral features or surface functionalization, and a lightweight machine-learning classifier differentiates acetone, methanol, ethanol, and isopropanol with 91.6% accuracy. These results establish porous metasurfaces as spatiotemporal sensing elements that couple quantitative vapor detection with kinetic fingerprinting through real-time dynamical responses, enabling low-cost, high-performance optical sensors.

Dash, Tomoshree [Clemson University]↗

Adaptive thermal stabilization of an integrated photonic spectrometer using parasitic interference fringes

Parasitic fringe drift from unwanted scatterings limits the long-term stability of waveguide-based optical spectrometers. Yet their spectral features provide relevant information that can be used to improve performance of the spectrometer. We show that fringe drift can be extracted and utilized to perform accurate thermal stabilization, especially in the case of integrated waveguide sensors. In this Letter, effective stabilization of a methane silicon photonic sensor is demonstrated, and significant reduction in fringe noise is clearly observed.

Teng, Chu C.↗

Ultra-High-Sensitivity Aerosol Spectrometer (UHSAS) Instrument Handbook

The Ultra-High-Sensitivity Aerosol Spectrometer (UHSAS) (Figure 1) is an optical-scattering, laser-based aerosol particle spectrometer system for sizing particles in the 60 to 1000 nanometer (nm) range [1–3]. The instrument counts particles in up to 100 user-specified sizing bins. The instrument’s laser illuminates particles, which scatter light. The system captures the peak light signals that are generated. These signals are used for particle sizing, since the amount of light scattered correlates strongly with particle size.

54 ENVIRONMENTAL SCIENCES↗

Portable Optical Particle Spectrometer aboard an Airborne Platform (POPS_AIR) Instrument Handbook

The U.S. Department of Energy Atmospheric Radiation Measurement (ARM) user facility portable optical particle spectrometer (POPS) is a lightweight particle spectrometer designed for aerosol particle size distribution measurement. Several POPS of different versions have been procured to serve as routine instruments for the ARM Aerial Facility (AAF) unmanned aerial systems (UAS) and tethered balloon system (TBS) deployment since 2018. POPS measures the aerosol particle size distribution approximately between 0.13 and 3 μm.

54 ENVIRONMENTAL SCIENCES↗

Systematic Study of Spectrometer-Induced Azimuthal Asymmetries for SpinQuest

SpinQuest is a transversely polarized Drell-Yan experiment at Fermilab that will measure the Sivers asymmetry for the light antiquarks in the nucleon, using polarized NH3 and ND3 targets and the SeaQuest (E906) spectrometer. Measuring a non-zero Sivers asymmetry would provide strong evidence for non-zero sea-quark orbital angular momentum. Due to the time-dependence of the spectrometer efficiency, and the fluctuations of the beam luminosity, a false azimuthal asymmetry can be introduced that could masquerade as a Sivers asymmetry. In this study, a systematic study of false azimuthal asymmetries using SeaQuest data is presented. This work is supported by the US Department of Energy, Office of Science, Medium Energy Nuclear Physics Program.

72 PHYSICS OF ELEMENTARY PARTICLES AND FIELDS↗

Ice Nucleation Spectrometer (INS) Instrument Handbook

The Ice Nucleation Spectrometer (INS) is an offline analytical measurement system used to process filter samples for freezing temperature spectra of immersion-mode ice nucleating particle (INP) number concentrations. It is almost identical to the CSU Ice Spectrometer (IS) design. While basic immersion freezing methods have been applied for decades, recent intercomparison studies (DeMott et al. 2017, 2018b) with other methods for sampling ambient INPs support the method’s utility. Use of the INS with filters produces spectra spanning wide dynamic ranges of temperature and, hence, INP concentration (e.g., six orders of magnitude). The INS is supported with well-established experimental protocols and has been applied in many diverse scenarios.

54 ENVIRONMENTAL SCIENCES↗

SOFIA: Spectrometer Optimized for Facility Integrated Applications

Los Alamos National Laboratory researchers developed the Spectrometer Optimized for Facility Integrated Applications (SOFIA) for new capabilities in non-destructive nuclear material analysis, nuclear data measurements, and actinide science. SOFIA is the first ultra-high resolution gamma spectrometer technology based on low-temperature microcalorimeter designs. By precisely measuring the gamma rays passively emitted from radioactive and nuclear materials, SOFIA provides rapid, completely nondestructive analysis to improve the economics and timeliness of nuclear material analysis by reducing reliance on costly sampling and destructive analysis. By developing the first compact instrument based on ultrahigh resolution microcalorimeter gamma spectroscopy, the researchers intended to bring this technology into practical use in nuclear facilities and analytical laboratories.

46 INSTRUMENTATION RELATED TO NUCLEAR SCIENCE AND ↗

CERBERUS: A Multi-Purpose Spectrometer and Alignment Station at SNS

In order to maximally utilize the existing beam ports at the Spallation Neutron Source, development and installation of a new neutron instrument is proposed at beam port 16a within building 8700 at Oakridge National Laboratory. Said instrument will provide nominally equal neutron beam access for three main science purposes; (1) as an alignment station for proposed single-crystal spectrometer samples to be run across the facility, (2) as a Near-Infrared (>100meV) filter analyzer spectrometer, nearly identical to that which was previously housed at the Lujan Center in Los Alamos, and (3) as a high-throughput nuclear cross-section measurement station. These three experimental applications would require no substantial technical developments, are complimentary in their technical requirements, and provide a worth-while capability that is infinitely beyond the current use of the 16a beam port at the First Target Station within the SNS complex. All three methods would enhance the facility’s science contributions, while accommodating two niche experiment methods that may not be strong enough to stand on their own.

46 INSTRUMENTATION RELATED TO NUCLEAR SCIENCE AND ↗

Rapid Fabrication of High Frame Rate Multichannel FTIR Spectrometers

Spectrally resolved signals in the short- to mid-wave infrared (SWIR/MWIR) bands at high-temporal resolution are critical for many national security remote sensing missions. Currently available off the shelf technology can achieve either high temporal resolution or high spectral resolution, but rugged instruments that can achieve both simultaneously remain mostly in the realm of one-off R&D projects. This report documents efforts to demonstrate a new technique for designing and building high resolution, high framerate multichannel FTIR (MC-FTIR) spectrometers that operate in the SWIR/MWIR bands. The core optical element in a MC-FTIR spectrometer is an array of statically-tuned lamellar grating interferometers (LGI). In the original MC-FTIR work these arrays were fabricated using a synchrotron x-ray lithography method. We proposed to instead fabricate these LGI arrays using multiphoton lithography (MPL), a 3D printing technique that can fabricate meso-scale structures with sub-micron precision. Although we were able to fabricate LGI arrays of sufficient size using MPL, the realized optical surfaces had unsuitably high optical form errors, precluding their use in a fieldable instrument. Further advancement in MPL technology may eventually enable fabrication of interferometer-grade LGI arrays.

46 INSTRUMENTATION RELATED TO NUCLEAR SCIENCE AND ↗