Engineering Papers⌕ Search

SEARCH · Engineering Papers

Results for “SPE”

Search indexed NASA NTRS and DOE OSTI research on propulsion, heat transfer, battery materials and energy systems. Follow report and document links to the original sources.

Quote a phrase for an exact phrase match. Source license links do not imply unrestricted reuse.

At least 433 records · Page 24

Role of salt concentration in blend polymer for energy storage conversion devices

Solid Polymer Electrolytes (SPE) are materials of considerable interest worldwide, which serves dual purpose of electrolyte and separator between electrode compartments in renewable energy conversion/storage devices such as; high energy density batteries, electrochromic display devices, and supercapacitors. Polymer blend electrolytes are prepared for various concentration of salt (Ö/Li) with the constant ratio (0.5 gm) of each PEO and PAN polymers (blend polymer) using solution casting technique. Solid polymeric ionic conductor as a separator is the ultimate substitute to eliminate the drawback related to liquid and gel polymer ionic conductors. In the present work, solid polymer electrolyte film consisting of PEO, PAN and LiPF{sub 6} are examined for various concentration of lithium salt by keeping PEO/PAN blend ratio as a constant with a view to optimize the dominant salt concentration which could give the maximum conductivity at ambient temperature.

75 CONDENSED MATTER PHYSICS, SUPERCONDUCTIVITY AND↗

Ion beam irradiation as a tool to improve the ionic conductivity in solid polymer electrolyte systems

Solid polymer electrolytes (SPEs) have potential applications in solid state electronic and energy devices. The optimum conductivity of SPEs required for such applications is about 10{sup −1} – 10{sup −3} Scm{sup −1}, which is hard to achieve in these systems. It is observed that ionic conductivity of SPEs continuously increase with increasing concentration of inorganic salt in the host polymer. However, there is a critical concentration of the salt beyond which the conductivity of SPEs decreases due to the formation of ion pairs. In the present study, solid polymer thin films based on poly (ethylene oxide) (PEO) complexed with NaBr salt with different concentrations have been prepared and the concentration at which ion pair formation occurs in PEO{sub x}NaBr is identified. The microstructure of the SPE with highest ionic conductivity is modified by irradiating it with low energy O{sup +1} ion (100 keV) of different fluencies. It is observed that the ionic conductivity of irradiated SPEs increases by one order in magnitude. The increase in ionic conductivity may be attributed to the enhanced segmental motion of the polymer chains due to radiation induced micro structural modification.

75 CONDENSED MATTER PHYSICS, SUPERCONDUCTIVITY AND↗

Enhancement in ionic conductivity on solid polymer electrolytes containing large conducting species

Solid Polymer Electrolytes (SPEs) lack better conducting properties at ambient temperatures. Various methods to enhance their ionic conductivity like irradiation with swift heavy ions, γ-rays, swift electrons and quenching at low temperature etc., have been explored in the literature. Among these, one of the oldest methods is incorporation of different conducting species into the polymer matrix and/or addition of nano-sized inert particles into SPEs. Various new salts like LiBr, Mg(ClO{sub 4}){sub 2}, NH{sub 4}I etc., have already been tried in the past with some success. Also various nanoparticles like Al{sub 2}O{sub 3}, TiO{sub 2} etc., have been tried in the past. In this article, we have investigated an SPE containing Rubidium as a conducting species. Rubidium has a larger ionic size compared to lithium and sodium ions which have been investigated in the recent past. In the present article, we have investigated the conductivity of large sized conducting species and shown the enhancement in the ionic conductivity by addition of nano-sized inert particles.

77 NANOSCIENCE AND NANOTECHNOLOGY↗

Tomography of atomic number and density of materials using dual-energy imaging and the Alvarez and Macovski attenuation model

Dual-energy computed tomography and the Alvarez and Macovski [Phys. Med. Biol. 21, 733 (1976)] transmitted intensity (AMTI) model were used in this study to estimate the maps of density (ρ) and atomic number (Z) of mineralogical samples. In this method, the attenuation coefficients are represented [Alvarez and Macovski, Phys. Med. Biol. 21, 733 (1976)] in the form of the two most important interactions of X-rays with atoms that is, photoelectric absorption (PE) and Compton scattering (CS). This enables material discrimination as PE and CS are, respectively, dependent on the atomic number (Z) and density (ρ) of materials [Alvarez and Macovski, Phys. Med. Biol. 21, 733 (1976)]. Dual-energy imaging is able to identify sample materials even if the materials have similar attenuation coefficients at single-energy spectrum. We use the full model rather than applying one of several applied simplified forms [Alvarez and Macovski, Phys. Med. Biol. 21, 733 (1976); Siddiqui et al., SPE Annual Technical Conference and Exhibition (Society of Petroleum Engineers, 2004); Derzhi, U.S. patent application 13/527,660 (2012); Heismann et al., J. Appl. Phys. 94, 2073–2079 (2003); Park and Kim, J. Korean Phys. Soc. 59, 2709 (2011); Abudurexiti et al., Radiol. Phys. Technol. 3, 127–135 (2010); and Kaewkhao et al., J. Quant. Spectrosc. Radiat. Transfer 109, 1260–1265 (2008)]. This paper describes the tomographic reconstruction of ρ and Z maps of mineralogical samples using the AMTI model. The full model requires precise knowledge of the X-ray energy spectra and calibration of PE and CS constants and exponents of atomic number and energy that were estimated based on fits to simulations and calibration measurements. The estimated ρ and Z images of the samples used in this paper yield average relative errors of 2.62% and 1.19% and maximum relative errors of 2.64% and 7.85%, respectively. Furthermore, we demonstrate that the method accounts for the beam hardening effect in density (ρ) and atomic number (Z) reconstructions to a significant extent.

71 CLASSICAL AND QUANTUM MECHANICS, GENERAL PHYSIC↗

Selective enrichment of phenols from coal liquefaction oil by solid phase extraction method

This study focuses on the solid phase extraction method for the enrichment and separation of phenol from coal liquefaction oil. The phenols' separation efficiency was compared on different solid phase extraction (SPE) cartridges, and the effect of solvents with different polarity and solubility parameter on amino-bonded silica was compared for selection of optimal elution solution. The result showed that amino-bonded silica has the highest selectivity and best extraction capability due to two factors, weak anion exchange adsorption and polar attraction adsorption.

01 COAL, LIGNITE, AND PEAT↗

Advances in the Large Area Picosecond Photo-Detector (LAPPD TM ): 8" × 8" MCP-PMT with Capacitively Coupled Readout

Abstract We present advances made in the Large Area Picosecond Photodetector (LAPPD), an 8" × 8" microchannel plate photomultiplier tube (MCP-PMT), since pilot production was initiated at Incom, Inc. in 2018. The Gen-I LAPPD utilizes a stripline anode for direct charge readout. The novel Gen-II LAPPD employs an internal resistive thin-film which capacitively couples to a customizable external signal readout board, streamlining production and increasing customer flexibility. The Gen-II LAPPD, with an active area of 373 cm 2 , is capable of high single photoelectron (PE) gain of ∼10 7 , low dark rates (∼1 kHz/cm 2 ), single PE (SPE) timing resolution of ∼65 ps, and 𝒪(mm) position resolution. Coupled with a UV-grade fused silica window, the LAPPD features a high quantum efficiency (QE) bialkali photocathode of >30% at 365 nm with spectral response down to ∼165 nm. The LAPPD is an excellent candidate for electromagnetic calorimeter (ECAL) timing layers, photon-based neutrino detectors, high energy collider experiments, medical imaging systems, and nuclear non-proliferation applications.

Instruments & Instrumentation↗

Stochastic pump effect and geometric phases in dissipative and stochastic systems

The success of Berry phases in quantum mechanics stimulated the study of similar phenomena in other areas of physics, including the theory of living cell locomotion and motion of patterns in nonlinear media. More recently, geometric phases have been applied to systems operating in a strongly stochastic environment, such as molecular motors. We discuss such geometric effects in purely classical dissipative stochastic systems and their role in the theory of the stochastic pump effect (SPE).

97 MATHEMATICS AND COMPUTING↗

Quantitative Method Development and Validation of Naloxone and 6α‐naloxol from Male African Green Monkey Plasma.

Theopioid epidemic is a rapidly growing crisis around the world. Current models forpharmacokinetic assessment of countermeasures use African green monkeys (AGM). Arapid, sensitive and selective method was developed and validated usingLC‐MS/MS for the determination of naloxone and 6α‐naloxol in AGM plasma. Samplepreparation involved a simple solid phase extraction (SPE) using ahydrophilic‐lipophilic‐balanced reversed‐phase cartridge. Separation of naloxoneand 6α‐naloxol was achieved on a Halo C18, 2.1 × 50 mm, 2.7μ analytical columnusing an Agilent 1290 Infinity HPLC. A solvent system of methanol‐water‐formicacid was used for the elution of analytes. The analytes were detected and monitoredby a SCIEX QTRAP 6500 + triple quadrupole tandem mass spectrometer operatedin electrospray ionization (ESI) positive mode and multiple reaction monitoring(MRM). Molecular ion transitions for naloxone, 6α‐naloxol and naloxone‐D5 were 328.0/212.0,330.0/185.0, and 333.1/212.0 m/z, respectively. The method was validated usingcalibration and recovery assays with spiked samples. Linear calibration curveswere generated over the range of 1.5–100 ng/ml with values for the coefficientof determination (R 2 ) of >0.9950. The values for both inter‐dayand intra‐day precision and accuracy were well within the generally acceptedcriteria for analytical methods (≤15%). This method was subsequentlyused to measure plasma concentrations of naloxone and 6α‐naloxol in male AGMs administerednaloxone subcutaneously and intravenously. The developed method demonstratedexcellent recovery, repeatability, accuracy and sensitivity. Support or Funding Information DISCLAIMERS. The views expressed in this abstractare those of the authors (s) and do not reflect the official policy of theDepartment of Army, Department of Defense, or U. S. Government. This researchwas supported by the Defense Threat Reduction Agency – Joint Science andTechnology office, Medical S&T Division. Thisproject was supported in part by an appointment to the Research ParticipationProgram for the U.S. Army Medical Research and Materiel Command administratedby the Oak Ridge Institute for Science and Education through an agreementbetween the U.S. Army Medical Research and Materiel Command. This abstract is from the Experimental Biology 2018 Meeting. There is no full text article associated with this abstract published in The FASEB Journal .

Bandaru, Veera Venkata Ratnam↗

One-neutron transfer study of Xe 137 and systematics of 13 / 2 1 + and 13 / 2 2 + levels in N = 83 nuclei

Excited states in 137 Xe have been studied by using the near-barrier single-neutron transfer reactions 13 C( 136 Xe, 12 C ) 137 Xe and 9 Be( 136 Xe, 8 Be ) 137 Xe in inverse kinematics.Particle- and particle- coincidence measurements have been performed with the Phoswich Wall and Digital Gammasphere detector arrays. Evidence is found for a 13/2 + 2 level (E = 3137 keV) and for additional high-lying 3/2 – and 5/2 – states. The results are discussed in the framework of realistic shell-model calculations. These calculations are also extended to the 13/2 + 1 and 13/2 + 2 levels in the N = 83 isotonic chain. Furthermore, they indicate that there is a need for a value of the neutron 0i 13/2 single-particle energy (E SPE = 2366 keV) lower than the one proposed in the literature. It is also demonstrated that the population patterns of the j = l ± 1/2 single-particle states in 137 Xe are different for the two targets used in these measurements and the implications of this effect are addressed.

73 NUCLEAR PHYSICS AND RADIATION PHYSICS↗

Time-Resolved Line Shapes of Single Quantum Emitters via Machine Learned Photon Correlations

Solid-state single-photon emitters (SPEs) are quantum light sources that combine atomlike optical properties with solid-state integration and fabrication capabilities. SPEs are hindered by spectral diffusion, where the emitter’s surrounding environment induces random energy fluctuations. Timescales of spectral diffusion span nanoseconds to minutes and require probing single emitters to remove ensemble averaging. Photon correlation Fourier spectroscopy (PCFS) can be used to measure time-resolved single emitter line shapes, but is hindered by poor signal-to-noise ratio in the measured correlation functions at early times due to low photon counts. Here, we develop a framework to simulate PCFS correlation functions directly from diffusing spectra that match well with experimental data for single colloidal quantum dots. We use these simulated datasets to train a deep ensemble autoencoder machine learning model that outputs accurate, noiseless, and probabilistic reconstructions of the noisy correlations. Using this model, we obtain reconstructed time-resolved single dot emission line shapes at timescales as low as 10 ns, which are otherwise completely obscured by noise. This enables PCFS to extract optical coherence times on the same timescales as Hong-Ou-Mandel two-photon interference, but with the advantage of providing spectral information in addition to estimates of photon indistinguishability. Further, our machine learning approach is broadly applicable to different photon correlation spectroscopy techniques and SPE systems, offering an enhanced tool for probing single emitter line shapes on previously inaccessible timescales.

74 ATOMIC AND MOLECULAR PHYSICS↗

Enhancement of satellite precipitation estimation via unsupervised dimensionality reduction

A methodology to enhance Satellite Precipitation Estimation (SPE) using unsupervised dimensionality reduction (UDR) techniques is developed. This enhanced technique is an extension to the Precipitation Estimation from Remotely Sensed Imagery using an Artificial Neural Network (PERSIANN) and Cloud Classification System (CCS) method (PERSIANN-CCS) enriched using wavelet features combined with dimensionality reduction. Cloud-top brightness temperature measurements from Geostationary Operational Environmental Satellite (GOES-12) are used for precipitation estimation at 4 km 4 km spatial resolutions every 30 min. The study area in the continental United States covers parts of Louisiana, Arkansas, Kansas, Tennessee, Mississippi, and Alabama. Based on quantitative measures, root mean square error (RMSE) and Heidke skill score (HSS), the results show that the UDR techniques can improve the precipitation estimation accuracy. In addition, ICA is shown to have better performance than other UDR techniques; and in some cases, it achieves 10% improvement in the HSS.

Mahrooghy, Majid↗

Material Model Parameters Optimization in Liquid Mercury Target Dynamics Simulation With Machine Learning Surrogates

A pulsed spallation target is subjected to very short (∼0.7μs) but intense loads (23.3 kJ) from repeated proton pulses, which knock away neutrons from the mercury atoms’ nuclei for a wide range application in physics, engineering, medicine, petroleum exploration, biology, chemistry, etc. The effect of this pulsed loading on the stainless-steel target module which contains the flowing mercury target material is difficult to predict not only due to its short but intense explosive-like physical reaction, but also the nonlinear material behavior of the liquid mercury in the structure. Injecting small helium bubbles in the mercury has been an efficient method of mitigating the pressure wave at high power level stage. However, prediction of the resultant loading on the target is more difficult when helium gas is intentionally injected into the mercury. A 2-phase material model that incorporates the Rayleigh-Plesset (R-P) model is expected to address this complex multi-physics dynamics problem by including the bubble dynamics in the liquid mercury. A parameter sensitivity study was firstly employed to understand their impact on the simulation strains. The investigated parameters included E, μ, γ, σ, n, VFgas, and gas cumulative volume curve control parameters a and b. Verification and validation results from sparse polynomial expansions (SPE) method and directional Gaussian smoothing (DGS) optimization show that the surrogate model had training error of ∼7% and validation error of ∼15%, indicating that machine learning methods and surrogate models can help optimize the uncertain parameters in the complex 2-phase material model. This approach is expected to fill the knowledge gap between unknown liquid-gas mixture material model and measured vessel strain responses.

Lin, Lianshan↗

Doping of IV-VI semiconductors and the energy spectrum of holes with resonance states taken into account

Kinetic phenomena in the Pb{sub 0.5}Sn{sub 0.5}Te solid solution have been studied in wide ranges of concentrations and temperatures in the case of two types of acceptor doping: with overstoichiometric tellurium and with a combination of equal amounts of Na and Te atoms; in the latter case, two additives amounting to 1.0 and 1.5 at % of each element have been used. Hole densities attained in this case significantly exceeded the largest values corresponding to the Pb{sub 0.5}Sn{sub 0.5} Te:Te samples. For both types of acceptors, the hole concentration in the solid solution is found to be a factor of 2 higher than in PbTe with the same level of doping. The specific features of behavior of the Hall coefficient, thermopower, and electrical conductivity are interpreted in the context of a model of a single-valence-band spe ctrum with a wide band of resonant levels. The mechanism of formation of resonant levels in PbTe and Pb{sub 0.5}Sn{sub 0.5} Te solid solutions is discussed.

36 MATERIALS SCIENCE↗

Coupling Front-End Separations, Ion Mobility Spectrometry, and Mass Spectrometry For Enhanced Multidimensional Biological and Environmental Analyses

Ion mobility spectrometry (IMS) is a widely used analytical technique for rapid molecular separations in the gas phase. IMS alone is useful, but its coupling with mass spectrometry (MS) and front-end separations has been extremely beneficial for increasing measurement sensitivity, peak capacity of complex mixtures, and the scope of molecular information in biological and environmental sample analyses. Multiple studies in disease screening and environmental evaluations have even shown these IMS-based multidimensional separations extract information not possible with each technique individually. This review highlights 3-dimensional separations using IMS-MS in conjunction with a range of front-end techniques, such as gas chromatography (GC), supercritical fluid chromatography (SFC), liquid chromatography (LC), solid phase extractions (SPE), capillary electrophoresis (CE), field asymmetric ion mobility spectrometry (FAIMS), and microfluidic devices. The origination, current state, various applications, and future capabilities for these multidimensional approaches are described to provide insight into the utility and potential of each technique.

Environmental Molecular Sciences Laboratory↗

Gamma-ray Exportable Adjustable Spectrum Evolution

An initial number of fissions on a fissile/fissionable material, defined by ENDF library availability, is used to produce an initial inventory of fission products (FPs). The FPs are decayed using full, analytical solutions to the Bateman equations to calculate the FP inventory at a user-specified time. The radiation detector, a high-purity germanium (HPGe) detector, has been modeled using every gamma-ray in the ENDF/TENDL libraries individually, and the modeled response can be multiplied by the activity of each fission product to determine a full, energy dependent detector response, including dead time. The detector response can be output as a PeakEasy (.spe) file, or as a text file. Since each radioisotope's inventory is known, the proportion to the total may be shown for each isotope, as well as many radionuclides in a user-specified energy window. Full execution and display of results takes 1-3 seconds, depending on the complexity of the input parameters.

Holschuh, ThomasV [Idaho National Laboratory (INL)↗

Single-Photon Generation: Materials, Techniques, and the Rydberg Exciton Frontier

Due to their quantum nature, single-photon emitters (SPE) generate individual photons in bursts or streams. They are paramount in emerging quantum technologies such as quantum key distribution, quantum repeaters, and measurement-based quantum computing. Many such systems have been reported in the last three decades, from rubidium atoms coupled to cavities to semiconductor quantum dots and color centers implanted in waveguides. This review article highlights different solid-state and atomic systems with on-demand and controlled single-photon generation. We discuss and compare the performance metrics, such as purity and indistinguishability, for these sources and evaluate their potential for different applications. Finally, a new potential single-photon source, based on the Rydberg exciton in solid-state metal oxide thin films, is introduced, where we discuss its promising features and unique advantages in fabricating quantum chips for quantum photonic applications.

71 CLASSICAL AND QUANTUM MECHANICS, GENERAL PHYSIC↗

NASA’s first ground-based Galactic Cosmic Ray Simulator: Enabling a new era in space radiobiology research

With exciting new NASA plans for a sustainable return to the moon, astronauts will once again leave Earth’s protective magnetosphere only to endure higher levels of radiation from galactic cosmic radiation (GCR) and the possibility of a large solar particle event (SPE). Gateway, lunar landers, and surface habitats will be designed to protect crew against SPEs with vehicle optimization, storm shelter concepts, and/or active dosimetry; however, the ever penetrating GCR will continue to pose the most significant health risks especially as lunar missions increase in duration and as NASA sets its aspirations on Mars. The primary risks of concern include carcinogenesis, central nervous system (CNS) effects resulting in potential in-mission cognitive or behavioral impairment and/or late neurological disorders, degenerative tissue effects including circulatory and heart disease, as well as potential immune system decrements impacting multiple aspects of crew health. Characterization and mitigation of these risks requires a significant reduction in the large biological uncertainties of chronic (low-dose rate) heavy-ion exposures and the validation of countermeasures in a relevant space environment. Historically, most research on understanding space radiation-induced health risks has been performed using acute exposures of monoenergetic single-ion beams. However, the space radiation environment consists of a wide variety of ion species over a broad energy range. Using the fast beam switching and controls systems technology recently developed at the NASA Space Radiation Laboratory (NSRL) at Brookhaven National Laboratory, a new era in radiobiological research is possible. NASA has developed the “GCR Simulator” to generate a spectrum of ion beams that approximates the primary and secondary GCR field experienced at human organ locations within a deep-space vehicle. The majority of the dose is delivered from protons (approximately 65%–75%) and helium ions (approximately 10%–20%) with heavier ions (Z ≥ 3) contributing the remainder. The GCR simulator exposes state-of-the art cellular and animal model systems to 33 sequential beams including 4 proton energies plus degrader, 4 helium energies plus degrader, and the 5 heavy ions of C, O, Si, Ti, and Fe. A polyethylene degrader system is used with the 100 MeV/n H and He beams to provide a nearly continuous distribution of low-energy particles. A 500 mGy exposure, delivering doses from each of the 33 beams, requires approximately 75 minutes. To more closely simulate the low-dose rates found in space, sequential field exposures can be divided into daily fractions over 2 to 6 weeks, with individual beam fractions as low as 0.1 to 0.2 mGy. In the large beam configuration (60 × 60 cm 2 ), 54 special housing cages can accommodate 2 to 3 mice each for an approximately 75 min duration or 15 individually housed rats. On June 15, 2018, the NSRL made a significant achievement by completing the first operational run using the new GCR simulator. This paper discusses NASA’s innovative technology solution for a ground-based GCR simulator at the NSRL to accelerate our understanding and mitigation of health risks faced by astronauts. Ultimately, the GCR simulator will require validation across multiple radiogenic risks, endpoints, doses, and dose rates.

59 BASIC BIOLOGICAL SCIENCES↗

Low-dimensional solid-state single-photon emitters

Solid-state single-photon emitters (SPEs) are attracting significant attention as fundamental components in quantum computing, communication, and sensing. Low-dimensional materials-based SPEs (LD-SPEs) have drawn particular interest due to their high photon extraction efficiency, ease of integration with photonic circuits, and strong coupling with external fields. The accessible surfaces of LD materials allow for deterministic control over quantum light emission, while enhanced quantum confinement and light–matter interactions improve photon emissive properties. This perspective examines recent progress in LD-SPEs across four key materials: zero-dimensional (0D) semiconductor quantum dots, one-dimensional (1D) nanotubes, two-dimensional (2D) materials, including hexagonal boron nitride (hBN) and transition metal dichalcogenides (TMDCs). We explore their structural and photophysical properties, along with techniques such as spectral tuning and cavity coupling, which enhance SPE performance. Finally, we address future challenges and suggest strategies for optimizing LD-SPEs for practical quantum applications.

42 ENGINEERING↗