Engineering Papers⌕ Search

SEARCH · Engineering Papers

Results for “SMART”

Search indexed NASA NTRS and DOE OSTI research on propulsion, heat transfer, battery materials and energy systems. Follow report and document links to the original sources.

Quote a phrase for an exact phrase match. Source license links do not imply unrestricted reuse.

At least 433 records · Page 24

Smartly Optimizing Crystallinity, Compatibility, and Morphology for Polymer Solar Cells by Small Molecule Acceptor with Unique 2D-EDOT Side Chain

A desired morphology is essential for achieving efficient polymer solar cells. Donors and acceptors with appropriate crystallization can lead to a suitable phase-separated morphology for effective photocurrent generation process. Inspired by the success of Y6 acceptors and the 2D side chain engineering on popular polymer donors and small molecule acceptors, the usage of unique 2D 3,4-ethylene dioxythiophene (EDOT) side chains on Y6 to regulate its crystallinity, compatibility, and thus the related blend morphology is explored. Here, in this study, two molecules of BTP-EDOT-4F and BTP-EDOT-4Cl with such unique 2D EDOT side chains are designed and synthesized. Due to the advantage of EDOT side chain, when these molecules are blended with PM6, the decent power conversion efficiencies (PCEs) of 16.78% and 15.87% are obtained. Furthermore, BTP-EDOT-4F is selected as the third component and added into PM6:L8-BO binary system to form ternary blends. The optimized crystallinity, compatibility, and morphology of such ternary blend are discovered in the presence of BTP-EDOT-4F, which enables efficient exciton dissociation and charge transport as well as decreased recombination, resulting in higher short circuit current density (J sc ) and fill factor. Finally, the outstanding PCE of 18.56% is achieved in ternary blends containing PM6, L8-BO, and BTP-EDOT-4F.

2D EDOT side chains↗

Single‐Domain Multiferroic Array‐Addressable Terfenol‐D (SMArT) Micromagnets for Programmable Single‐Cell Capture and Release

Abstract Programming magnetic fields with microscale control can enable automation at the scale of single cells ≈10 µm. Most magnetic materials provide a consistent magnetic field over time but the direction or field strength at the microscale is not easily modulated. However, magnetostrictive materials, when coupled with ferroelectric material (i.e., strain‐mediated multiferroics), can undergo magnetization reorientation due to voltage‐induced strain, promising refined control of magnetization at the micrometer‐scale. This work demonstrates the largest single‐domain microstructures (20 µm) of Terfenol‐D (Tb 0.3 Dy 0.7 Fe 1.92 ), a material that has the highest magnetostrictive strain of any known soft magnetoelastic material. These Terfenol‐D microstructures enable controlled localization of magnetic beads with sub‐micrometer precision. Magnetically labeled cells are captured by the field gradients generated from the single‐domain microstructures without an external magnetic field. The magnetic state on these microstructures is switched through voltage‐induced strain, as a result of the strain‐mediated converse magnetoelectric effect, to release individual cells using a multiferroic approach. These electronically addressable micromagnets pave the way for parallelized multiferroics‐based single‐cell sorting under digital control for biotechnology applications.

Khojah, Reem↗

Human‐Skin‐Inspired Adaptive Smart Textiles Capable of Amplified Latent Heat Transfer for Thermal Comfort

Thermally adaptive textiles (TATs) enable human subjects to attain thermal comfort without energy consumption, which can lead to enormous energy savings on heating, ventilation, and air conditioning (HVAC) in buildings. Herein, TAT structures which respond to the sweat and generate pores by opening an array of flap‐shaped pores patterned on the fabric surface are proposed. A moisture‐driven self‐actuator for flap opening by constructing a bilayer consisting of a hygroscopic layer using polyethylene glycol and cellulose acetate, and a hydrophobic polymer using a polyester type polymer, is used and successfully demonstrated an essentially instant 4 °C apparent temperature cooling performance within one minute of sweat–humidity‐initiated actuation while wearing TAT using a sweating skin simulated device.

Kim, Gunwoo↗

A simulation‐based integrated virtual testbed for dynamic optimization in smart manufacturing systems

Abstract In a manufacturing system, production control‐related decision‐making activities occur at different levels. At the process level, one of the main control activities is to tune the parameters of individual manufacturing equipment. At the system level, the main activity is to coordinate production resources and to route parts to appropriate workstations based on their processing requirement, priority indices, and control policy. At the factory level, the goal is to plan and schedule the processing of parts at different operations for the entire system in order to optimize certain objectives. Note that the results of such activities at different levels are closely coupled and affect the overall performance of the manufacturing system as a whole. Therefore, it is important to systematically integrate these control and optimization activities into one unified platform to ensure the goal of each individual activity is aligned with the overall performance of the system. In this paper, we develop a simulation‐based virtual testbed that implements dynamic optimization, automatic information exchange, and decision‐making from the process‐level, system‐level, and factory‐level of a manufacturing system into an integrated computation environment. This is demonstrated by connecting a Python‐based numerical computation program, discrete‐event simulation software (Simul8), and an optimization solver (CPLEX) via a third‐party master program. The application of this simulation‐based virtual testbed is illustrated by a case study in a machining shop.

Sun, Yuting↗

Federated Learning with Frequency Estimation for Smart Meter Systems

Federated learning (FL) is a powerful framework that enables multiple distributed clients to collaborate without the need to transfer their data to a central server. However, FL does not inherently guarantee the level of privacy that clients often require. In our review of recent studies on privacy-enhancing techniques in FL, we found that frequency estimation (FE) methods remain underexplored. To address this gap, we developed and integrated FE techniques on the client side, further examining the effects of incorporating an adaptive range and a shuffled model. We also analyzed the impact of varying hyper-parameters on privacy preservation. Our results provide clear guidance on the algorithms and configurations that are most effective for enhancing privacy in FL, particularly when using long short-term memory (LSTM) architectures.

Kotevska, Olivera [ORNL] (ORCID:0000000316772243)↗

Deep Reinforcement Learning Based Smart Water Heater Control for Reducing Electricity Consumption and Carbon Emission

Water heating is the third largest electricity consumer in U.S. households, after space heating and cooling. Thus, water heaters represent a significant potential for reducing electricity consumption and associated CO2 emissions of residential buildings. To this end, this study proposes a model-free deep reinforcement learning (RL) approach that aims to minimize the electricity consumption and the CO2 emissions of a heat pump water heater without affecting user comfort. In this approach, a set of RL agents focusing on either electricity saving or emission reduction, with different look ahead periods, were trained using the deep Q-networks (DQN) algorithm and their performance was tested on different hot water usage and Marginal Operating Emissions Rate (MOER) profiles. The testing results showed that the RL agents that focus on electricity saving can save electricity in the range of 12–22% by operating the water heater with maximum heat pump efficiency and minimum electric element utilization. On the other hand, the RL agents that focus on emission reduction reduced emissions in the range of 18–37% by making use of the variable MOER values. These RL agents used the heat pump and/or an element when the MOER values are low due to the availability of renewable energy sources (e.g., solar and wind) and mostly avoided the periods of carbon-intensive periods. Overall, these results showed that the proposed RL approach can help minimize the electricity consumption and the CO2 emissions of a heat pump water heater without having any prior knowledge about the device.

Amasyali, Kadir↗

A Novel Simulation-Based Framework for Sensor Error Impact Analysis in Smart Building Systems: A Case Study for a Demand-Controlled Ventilation System

Sensors are one of the fundamental components for sensor-rich controls in buildings but are prone to different errors. Existing studies show that sensor errors hold a place among top-priority faults in building systems. Before we take countermeasures to mitigate the sensor errors, it is vital to prioritize key sensors and quantify the collective impacts of concurrent sensor errors. In response to this, a simulation-based methodology is introduced to conduct a comprehensive sensor error impact analysis in building systems, which adds a stochastic sensor prioritization through a sensitivity analysis on top of a commonly used deterministic sensor error quantification. The synergies of these two parts help better interpret the sensor error impacts on building energy consumption, ventilation performance, thermal comfort, etc. A sensor-rich CO2-based Demand-Controlled Ventilation system is used as a case study to demonstrate the viability of the methodology as a proof-of-the-concept. The results show that the energy savings potential and ventilation performance are mostly influenced by the accuracy of the AHU outdoor airflow sensors. The accuracy of zone level airflow sensors has a negligible impact on both energy savings and ventilation performance. The accuracy of zone CO2 sensors has more influence on the ventilation performance compared with the accuracy of zone airflow sensors. Compared with the baseline case with zero errors, the largest deviation percentages could reach 16.90% and 94.32%, respectively, in terms of the Heating, Ventilation, and Air-Conditioning (HVAC) annual energy consumption and the Outdoor Air Ratio (OAR) when multiple key sensors suffer from normal error intensities simultaneously.

32 ENERGY CONSERVATION, CONSUMPTION, AND UTILIZATI↗

Evaluation of smart charging for electric vehicle-to-building integration: A case study

Higher electric vehicle (EV) adoption will stress the importance of demand flexibility to achieve more economic, efficient, and reliable grid operation. Charging technologies will be paramount in shifting temporally to better fit the variable generation of wind and solar. As such, analysis is warranted on the benefits of EV charge scheduling with respect to installation cost, operation cost, difficulty of implementation, and grid flexibility. We tackle this by analyzing the cost savings of implementing an EV charge scheduling infrastructure to reduce demand charges and installation costs. In this paper, we analyze a case study for operation of 16 level 2 chargers and 1 fast charger for two different building types. We then evaluate various test phases for controlling building and charging loads using an adaptive charging network (ACN) algorithm to characterize the ACN’s potential to reduce overall project cost.

30 DIRECT ENERGY CONVERSION↗

Blockchain Smart Contract Reference Framework and Program Logic Architecture for Transactive Energy Systems

This paper proposes a reference framework for a transactive energy market based on blockchain. The framework was designed based on the engineering requirements of a distribution-scale market; including participant needs, expected market transactions, and the cybersecurity constructs required to support a fair, secure and efficient market operation. It leverages the existing blockchain primitives to provide clear value propositions to the transactive market, including identity management (access control), data security (integrity), resiliency (decentralization, scalability and performance). The validity of the proposed framework is demonstrated using a real-time 5-min double-auction market. The results highlight its benefits while providing strong validation of applicability to blockchain within transactive energy systems.

Gourisetti, Sri Nikhil Gupta↗

Online transfer learning strategy for enhancing the scalability and deployment of deep reinforcement learning control in smart buildings

In recent years, advanced control strategies based on Deep Reinforcement Learning (DRL) proved to be effective in optimizing the management of integrated energy systems in buildings, reducing energy costs and improving indoor comfort conditions when compared to traditional reactive controllers. However, the scalability and implementation of DRL controllers are still limited since they require a considerable amount of time before converging to a near-optimal solution. This issue is currently addressed in literature through the offline pre-training of the DRL agent. However this solution results in two main critical issues: (1) the need to develop a building surrogate model to perform the training task, and (2) the need to perform a fine-tuning process over several training episodes to obtain a near-optimal control policy. In this context, this paper introduces an Online Transfer Learning (OTL) strategy that exploits two knowledge-sharing techniques, weight-initialization and imitation learning, to transfer a DRL control policy from a source office building to various target buildings in a simulation environment coupling EnergyPlus and Python. A DRL controller based on discrete Soft Actor–Critic (SAC) is trained on the source building to manage the operation of a cooling system consisting of a chiller and a thermal storage. Several target buildings are defined to benchmark the performance of the OTL strategy with that of a Rule-Based Controller (RBC) and two DRL-based control strategies, deployed in offline and online fashion. The strategy adopted for OTL emulates the real world implementation with a simulation process by implementing the transferred DRL agent for a single episode in the target buildings. Target buildings have the same geometrical features and are served by the same energy system as the source building, but differ in terms of weather conditions, electricity price schedules, occupancy patterns, and building envelope efficiency levels. The results show that the OTL strategy can reduce the cumulated sum of temperature violations on average by 50% and 80% respectively when compared to RBC and online DRL while enhancing the energy system operation with electricity cost savings ranging between 20% and 40%. Furthermore, the OTL agent performs slightly worse than the offline DRL controller but it does not require any modeling effort and can be implemented directly on target buildings emulating a real-world implementation.

32 ENERGY CONSERVATION, CONSUMPTION, AND UTILIZATI↗

Visibility-enhanced model-free deep reinforcement learning algorithm for voltage control in realistic distribution systems using smart inverters

Increasing integration of distributed solar photovoltaic (PV) into distribution networks could result in adverse effects on grid operation. Traditional model-based control algorithms require accurate model information that is difficult to acquire and thus are challenging to implement in practice. Here, this paper proposes a surrogate model-enabled grid visibility scheme to empower deep reinforcement learning (DRL) approach for distribution network voltage regulation using PV inverters with minimal system knowledge. In contrast to existing DRL methods, this paper presents and corroborates the adverse impact of missing load information on DRL performance and, based on this finding, proposes a surrogate model methodology to impute load information utilizing observable data. Additionally, a multi-fidelity neural network is utilized to construct the DRL training environment, chosen for its efficient data utilization and enhanced robustness to data uncertainty. The feasibility and effectiveness of the proposed algorithm are assessed by considering DRL testing across varying degrees of observable load information and diverse training environments on a realistic power system.

14 SOLAR ENERGY↗

Smart detection of indoor occupant thermal state via infrared thermography, computer vision, and machine learning

The ability to measure occupants’ thermal state in real time will enable major advances in the control of air conditioning systems. This study proposes predicting occupant thermal state by a combination of infrared thermography, computer vision, and machine learning. The approach (1) uses cheek, nose, and hand temperatures because they are least subject to blockage by hair, glasses, and clothing; (2) measures the distribution of skin temperatures within geometrically defined sub-areas of the face and hand; and (3) uses temperature differences within and between these areas to eliminate the effects of calibration drift that are unavoidable in thermal infrared (TIR) cameras. Two series of tests were conducted, respectively in an outdoor carport and an indoor environmental chamber, collecting a total of 48,422 sets of cheek, nose, and hand skin temperatures using a TIR camera and computer-vision technology, coupled with 715 subjective responses of thermal sensations. To predict occupant thermal state, Random Forest classification models were built using either absolute skin temperatures (the maximum and median temperatures of cheek and hand segments, and the temperature of the central spot on the nose), or intra- and inter-segment temperature differences of cheeks, hands, and nose. These measurements were found to accurately predict occupant thermal state. Using the maximum and median temperatures for cheek and nose, or for cheek and hand, predicts thermal state with an accuracy of 92–96%. In conclusion, using only the intra- and inter-segment temperature differences from cheek and nose is 83% accurate; adding the hand temperature differences increases the accuracy to 96%.

32 ENERGY CONSERVATION, CONSUMPTION, AND UTILIZATI↗

Effect of chloride ingress on self-healing recovery of smart cementitious composite incorporating crystalline admixture and MgO expansive agent

Highlights: • Crack closure under wet/dry cycles in chloride solution is higher than the one in distilled water. • Element analysis shows that calcium is vital for crack healing either in water or chloride solution. • AFm is consumed by chloride ion to form Fs, and Fs were decomposed to AH{sub 3} by carbonation. • Soluble reactive silica reacts with calcium hydrate to form C-S-H gel to heal concrete cracks. • Expansion of magnesium hydroxide facilitates crack self-healing by interconnected network. In this study, the effect of chloride environment containing various concentrations of chloride ion (Cl{sup −}) on self-healing performance of pre-cracked cementitious composite containing crystalline admixture (CA) and MgO expansive agent (MEA) was investigated under wet-dry cycles in chloride solutions. The results revealed that the Cl{sup −} changed the mineralogy of self-healing products, and consequently, affected the crack closure ratio and mechanical strength recovery. When self-healing occurred in distilled water, a large amount of ettringite (AFt) were detected, whereas in Cl{sup −} solution, monosulfate (AFm) was consumed by Cl{sup −} to form Friedel's salt (Fs), and then the Fs was decomposed to Al(OH){sub 3}(AH{sub 3}) due to carbonation. During the multiphase conversion process, hydroxide (OH{sup −}) was released into crack solution, therefore the dissolved carbon dioxide (CO{sub 2}) concentration was increased. The carbonation of the crystals formed in cracks was accelerated with the volume expansion, which achieved rapid crack sealing but contributed little to the mechanical performance recovery.

36 MATERIALS SCIENCE↗

Autogenous formation and smart behaviors of nitrite- and nitrate-intercalated layered double hydroxides (LDHs) in Portland cement-metakaolin-dolomite blends

In this work, the influence of sodium nitrite (NaNO{sub 2}) and sodium nitrate (NaNO{sub 3}) corrosion inhibitors on the composition, structure, and chloride binding behaviors of layered double hydroxides (LDHs) formed in ternary ordinary Portland cement-metakaolin-dolomite (OPC-MK-DM) systems is studied. The results show that the nitrite and nitrate anions are preferably intercalated in the CaAl LDHs (AFm phases), but not in the MgAl LDHs (hydrotalcite-type phases) due to its limited formation in these ternary cementitious systems cured at ambient temperature. The autogenously formed nitrate- and nitrite-AFm phases are decomposed upon chloride exposure accompanied by Friedel's salts formation, potentially releasing corrosion inhibitive ions to the pore solution in a progressive manner. The NaNO{sub 2} and NaNO{sub 3} incorporation in ternary OPC-MK-DM binders marginally lowers chloride binding capacity but reduces its penetration resistance mainly due to pore coarsening. Nevertheless, a strong linear correlation can be established between the water-soluble and total chloride contents in ternary OPC-MK-DM systems, regardless of OPC replacement level and corrosion inhibitor incorporation.

36 MATERIALS SCIENCE↗

Smart material based multilayered microbeam structures for spatial self-deployment and reconfiguration: A residual stress approach

Alleviation of the potentially damaging effects induced by residual stresses was comprehensively investigated in previous research. Here, this paper, however, presents a spatially self-deployable and reconfigurable multilayered microbeam which takes advantage of residual stresses and shape memory effects. Reconfigurable mechanism of a typical four-layered microbeam composed of Pt\Ni 50 Ti 50 \Ni 50 Ti 50 \Pt is introduced, followed by analytical modeling of the maximum distance of the self-deployed gap as functions of variable structural and material parameters, including compressive residual stress in Pt layers and tensile residual stress in Ni 50 Ti 50 layers. Analytical solutions given by the static model agree well with the results obtained via finite element models (FEMs). Fabrication, characterization, and in-situ experiments were carried out to validate the feasibility of deployment of the as-released four-layered microbeam. The maximum distance of the gap was measured to be 41.39 μm at 20 °C, which could be increased to 51.73 μm thanks to controllable reconfiguration driven by shape memory effects. Theoretical analysis of such self-deployment and reconfiguration suggested a tensile residual stress increase by 52 MPa in Ni 50 Ti 50 layers. The multilayered microbeam structure with capabilities of self-deployment and reconfiguration offers great potential for various emerging applications, such as micro robotics, medical drug delivery devices, and intelligent chip scale spacecraft.

36 MATERIALS SCIENCE↗