Engineering Papers⌕ Search

SEARCH · Engineering Papers

Results for “SIGNAL NOISE”

Search indexed NASA NTRS and DOE OSTI research on propulsion, heat transfer, battery materials and energy systems. Follow report and document links to the original sources.

Quote a phrase for an exact phrase match. Source license links do not imply unrestricted reuse.

At least 433 records · Page 24

Electron energy loss spectroscopy database synthesis and automation of core-loss edge recognition by deep-learning neural networks

Abstract The ionization edges encoded in the electron energy loss spectroscopy (EELS) spectra enable advanced material analysis including composition analyses and elemental quantifications. The development of the parallel EELS instrument and fast, sensitive detectors have greatly improved the acquisition speed of EELS spectra. However, the traditional way of core-loss edge recognition is experience based and human labor dependent, which limits the processing speed. So far, the low signal–noise ratio and the low jump ratio of the core-loss edges on the raw EELS spectra have been challenging for the automation of edge recognition. In this work, a convolutional-bidirectional long short-term memory neural network (CNN-BiLSTM) is proposed to automate the detection and elemental identification of core-loss edges from raw spectra. An EELS spectral database is synthesized by using our forward model to assist in the training and validation of the neural network. To make the synthesized spectra resemble the real spectra, we collected a large library of experimentally acquired EELS core edges. In synthesize the training library, the edges are modeled by fitting the multi-Gaussian model to the real edges from experiments, and the noise and instrumental imperfectness are simulated and added. The well-trained CNN-BiLSTM network is tested against both the simulated spectra and real spectra collected from experiments. The high accuracy of the network, 94.9%, proves that, without complicated preprocessing of the raw spectra, the proposed CNN-BiLSTM network achieves the automation of core-loss edge recognition for EELS spectra with high accuracy.

36 MATERIALS SCIENCE↗

Injection locking and coupling dynamics in superconducting nanowire-based cryogenic oscillators

Oscillators designed to function at cryogenic temperatures play a critical role in superconducting electronics and quantum computing by providing stable, low-noise signals with minimal energy loss. Here, in this work, we present a comprehensive numerical study of injection locking and mutual coupling dynamics in superconducting nanowire (ScNW)-based cryogenic oscillators. Using the design space of a standalone ScNW-based oscillator, we investigate two critical mechanisms that govern frequency synchronization and signal coordination in cryogenic computing architectures: (1) injection locking induced by an external AC signal with a frequency near the oscillator's natural frequency, and (2) the mutual coupling dynamics between two ScNW oscillators under varying coupling strengths. We identify key design parameters—such as shunt resistance, nanowire inductance, and coupling strength—that govern the locking range. Additionally, we examine how the amplitude of the injected signal affects the amplitude of the locked oscillation, offering valuable insights for power-aware oscillator synchronization. Furthermore, we analyze mutual synchronization between coupled ScNW oscillators using capacitive and resistive coupling elements. Our results reveal that the phase difference between oscillators can be controlled by tuning the coupling strength, enabling programmable phase-encoded information processing. These findings could enable building ScNW-based oscillatory neural networks, synchronized cryogenic logic blocks, and on-chip cryogenic resonator arrays.

Artificial neural networks↗

METALLICITY GRADIENTS AND GAS FLOWS IN GALAXY PAIRS

We present the first systematic investigation into the metallicity gradients in galaxy close pairs. We determine the metallicity gradients for eight galaxies in close pairs using H II region metallicities obtained with high signal-to-noise multi-slit observations with the Keck LRIS Spectrograph. We show that the metallicity gradients in close pairs are significantly shallower than gradients in isolated spiral galaxies such as the Milky Way, M83, and M101. These observations provide the first solid evidence that metallicity gradients in interacting galaxies are systematically different from metallicity gradients in isolated spiral galaxies. Our results suggest that there is a strong relationship between metallicity gradients and the gas dynamics in galaxy interactions and mergers.

79 ASTRONOMY AND ASTROPHYSICS↗

A new method for in situ structural investigations of nano-sized amorphous and crystalline materials using mixed-flow reactors

Structural investigations of amorphous and nanocrystalline phases forming in solution are historically challenging. Few methods are capable of in situ atomic structural analysis and rigorous control of the system. A mixed-flow reactor (MFR) is used for total X-ray scattering experiments to examine the short- and long-range structure of phases in situ with pair distribution function (PDF) analysis. The adaptable experimental setup enables data collection for a range of different system chemistries, initial supersaturations and residence times. The age of the sample during analysis is controlled by adjusting the flow rate. Faster rates allow for younger samples to be examined, but if flow is too fast not enough data are acquired to average out excess signal noise. Slower flow rates form older samples, but at very slow speeds particles settle and block flow, clogging the system. Proper background collection and subtraction is critical for data optimization. Overall, this MFR method is an ideal scheme for analyzing the in situ structures of phases that form during crystal growth in solution. As a proof of concept, high-resolution total X-ray scattering data of amorphous and crystalline calcium phosphates and amorphous calcium carbonate were collected for PDF analysis.

36 MATERIALS SCIENCE↗

Adversarial Attacks on Deep Neural Network-based Power System Event Classification Models

Online event classification is essential to strengthening the reliability of the power transmission system. Recently, deep learning based methods have achieved great success in numerous domains such as computer vision and natural language processing. Researchers began to adopt deep learning based methods to solve the power system event identification problem and achieved effective results. However, these previous works do not consider that deep learning models are vulnerable to adversarial attacks, potentially influencing real-world applications' reliability. In this paper, we adopt several adversarial attack mechanisms by adding tailored noise signal to the input Phasor Measurement Units (PMU) time series and make the deep learning model misclassify the power system event. This numerical study discloses that current state-of-the-art deep learning based power system event classifiers are extremely vulnerable to adversarial attacks, which may jeopardize the reliability of the power transmission system.

24 POWER TRANSMISSION AND DISTRIBUTION↗

A Coherence Method for Detecting and Analyzing Oscillations

In this paper, a coherence method is proposed to detect and analyze forced oscillations from phasor measurement unit data. The calculation of coherence spectrum is reviewed, and forced oscillations are related to the peaks in the coherence spectrum. Using simulation and field measurement data, the proposed coherence method’s performance is compared with the power spectral density method. When applied to detect and analyze forced oscillations under low signal noise ratio conditions, the proposed coherence method shows better performance.

coherence↗

Adaptive Circuit Learning for Quantum Metrology

Quantum sensing is an important application of emerging quantum technologies. We explore whether a hybrid system of quantum sensors and quantum circuits can surpass the classical limit of sensing. In particular, we use optimization techniques to search for encoder and decoder circuits that scalably improve sensitivity under given application and noise characteristics. Furthermore, our approach uses a variational algorithm that can learn a quantum sensing circuit based on platform-specific control capacity, noise, and signal distribution. The quantum circuit is composed of an encoder which prepares the optimal sensing state and a decoder which gives an output distribution containing information of the signal. We optimize the full circuit to maximize the Signal-to-Noise Ratio (SNR). Furthermore, this learning algorithm can be run on real hardware scalably by using the "parameter-shift" rule which enables gradient evaluation on noisy quantum circuits, avoiding the exponential cost of quantum system simulation. We demonstrate up to 13.12x SNR improvement over existing fixed protocol (GHZ), and 3.19x Classical Fisher Information (CFI) improvement over the classical limit on 15 qubits using IBM quantum computer. More notably, our algorithm overcomes the decreasing performance of existing entanglement-based protocols with increased system sizes.

42 ENGINEERING↗

Evaluation of Impedance Measurement Using Spread Spectrum Time Domain Reflectometry

We evaluate the feasibility of spectral time domain reflectometry (STDR) and spread spectrum time domain reflectometry (SSTDR) as a new modality for impedance measurement to test energized/noisy systems over a very broad frequency spectrum (near dc to gigahertz) as well as multiple channels in parallel. We simulate how the S/SSTDR signal parameters (signal-to-noise ratio (SNR) frequency and length of the pseudo-noise (PN) signals) affect the accuracy and usable frequency band for reflection coefficient and impedance measurement. An initial measurement validation is included. Here, we conclude with a recommendation of what will be required for a viable multichannel impedance (and reflection, transmission coefficient) measurement system for either energized or nonenergized systems, in noisy environments, that can test multiple channels simultaneously.

14 SOLAR ENERGY↗

A modular architecture for multi-channel external cavity quantum cascade laser-based chemical sensors: a systems approach

A multi-channel laser-based chemical sensor platform is presented, in which a modular architecture allows the exchange of complete sensor channels without disruption to overall operation. Each sensor channel contains custom optical and electronics packages, which can be selected to access laser wavelengths, interaction path lengths and modulation techniques optimal for a given application or mission. Although intended primarily to accommodate mid-infrared (MIR) external cavity quantum cascade lasers (ECQCLs)and astigmatic Herriott cells, channels using visible or near infrared (NIR) lasers or other gas cell architectures can also be used, making this a truly versatile platform. Analog and digital resources have been carefully chosen to facilitate small footprint, rapid spectral scanning, ow-noise signal recovery, failsafe autonomous operation, and in-situ chemometric data analysis, storage and transmission. Results from the demonstration of a two-channel version of this platform are also presented.

99 GENERAL AND MISCELLANEOUS↗

TU-F-CAMPUS-I-05: Semi-Automated, Open Source MRI Quality Assurance and Quality Control Program for Multi-Unit Institution

Purpose: Phantom measurements allow for the performance of magnetic resonance (MR) systems to be evaluated. Association of Physicists in Medicine (AAPM) Report No. 100 Acceptance Testing and Quality Assurance Procedures for MR Imaging Facilities, American College of Radiology (ACR) MR Accreditation Program MR phantom testing, and ACR MRI quality control (QC) program documents help to outline specific tests for establishing system performance baselines as well as system stability over time. Analyzing and processing tests from multiple systems can be time-consuming for medical physicists. Besides determining whether tests are within predetermined limits or criteria, monitoring longitudinal trends can also help prevent costly downtime of systems during clinical operation. In this work, a semi-automated QC program was developed to analyze and record measurements in a database that allowed for easy access to historical data. Methods: Image analysis was performed on 27 different MR systems of 1.5T and 3.0T field strengths from GE and Siemens manufacturers. Recommended measurements involved the ACR MRI Accreditation Phantom, spherical homogenous phantoms, and a phantom with an uniform hole pattern. Measurements assessed geometric accuracy and linearity, position accuracy, image uniformity, signal, noise, ghosting, transmit gain, center frequency, and magnetic field drift. The program was designed with open source tools, employing Linux, Apache, MySQL database and Python programming language for the front and backend. Results: Processing time for each image is <2 seconds. Figures are produced to show regions of interests (ROIs) for analysis. Historical data can be reviewed to compare previous year data and to inspect for trends. Conclusion: A MRI quality assurance and QC program is necessary for maintaining high quality, ACR MRI Accredited MR programs. A reviewable database of phantom measurements assists medical physicists with processing and monitoring of large datasets. Longitudinal data can reveal trends that although are within passing criteria indicate underlying system issues.

60 APPLIED LIFE SCIENCES↗

WE-AB-207A-02: John’s Equation Based Consistency Condition and Incomplete Projection Restoration Upon Circular Orbit CBCT

Purpose: In transmitted X-ray tomography imaging, projections are sometimes incomplete due to a variety of reasons, such as geometry inaccuracy, defective detector cells, etc. To address this issue, we have derived a direct consistency condition based on John’s Equation, and proposed a method to effectively restore incomplete projections based on this consistency condition. Methods: Through parameter substitutions, we have derived a direct consistency condition equation from John’s equation, in which the left side is only projection derivative of view and the right side is projection derivative of other geometrical parameters. Based on this consistency condition, a projection restoration method is proposed, which includes five steps: 1) Forward projecting reconstructed image and using linear interpolation to estimate the incomplete projections as the initial result; 2) Performing Fourier transform on the projections; 3) Restoring the incomplete frequency data using the consistency condition equation; 4) Performing inverse Fourier transform; 5) Repeat step 2)∼4) until our criteria is met to terminate the iteration. Results: A beam-blocking-based scatter correction case and a bad-pixel correction case were used to demonstrate the efficacy and robustness of our restoration method. The mean absolute error (MAE), signal noise ratio (SNR) and mean square error (MSE) were employed as our evaluation metrics of the reconstructed images. For the scatter correction case, the MAE is reduced from 63.3% to 71.7% with 4 iterations. Compared with the existing Patch’s method, the MAE of our method is further reduced by 8.72%. For the bad-pixel case, the SNR of the reconstructed image by our method is increased from 13.49% to 21.48%, with the MSE being decreased by 45.95%, compared with linear interpolation method. Conclusion: Our studies have demonstrated that our restoration method based on the new consistency condition could effectively restore the incomplete projections, especially for their high frequency component.

60 APPLIED LIFE SCIENCES↗

Low-background EN-detector for the investigation of the neutron component of EASs

Thermal neutrons are detected using a scintillator compound based on ZnS(Ag) with B{sub 2}O{sub 3} added to it. The pulse height generated by single charged particles in a scintillator of small thickness (50 mg/cm{sup 2}) is not larger than that of a noise signal due to a low sensitivity to single charged particles. As a result, the detector satisfies the requirements of a low-background one in the context of cosmic-ray experiments. The detector is to be used for neutron detection in extensive air showers.

46 INSTRUMENTATION RELATED TO NUCLEAR SCIENCE AND ↗

Active–Source Seismic Tomography at the Brady Geothermal Field, Nevada, with Dense Nodal and Fiber–Optic Seismic Arrays

We deployed a dense seismic array to image the shallow structure in the injection area of the Brady Hot Springs geothermal power plant in western Nevada. The array was composed of 238 three-component, 5 Hz nodal instruments, 8700 m of distributed acoustic sensing (DAS) fiber-optic cable (FOC) installed horizontally in surface trenches, and 400 m of FOC installed vertically in a borehole. The geophone array had about 60 m instrument spacing in the target zone, whereas DAS channel separations were about 1 m with an averaging (gauge) length of 10 m. The acquisition systems provided 15 days of continuous records, including active-source and ambient noise signals. A large vibroseis truck was operated at 196 locations, exciting a swept-frequency signal from 5 to 80 Hz over 20 s using three vibration modes (vertical, longitudinal, and transverse), with three sweeps per mode at each site. Sweeps were repeated up to four times at each site during four different stages of power plant operation: normal operation, shutdown, high and oscillatory injection and production, and normal operation. After removal of the sweep signal from the raw data, the first P-wave arrivals were automatically picked using a combination of methods. Here, the travel times were then used to invert for the 3D P-wave velocity structure. Models with 100 m horizontal and 20–50 m vertical node spacing were obtained, covering an area 2000 m by 1300 m, with acceptable resolution extending to about 250 m below surface. The travel-time data were fit to a root mean square (rms) misfit of 31 ms, close to our estimated picking uncertainty. Lateral boundaries between high and low velocity zones agree relatively well with the location of local faults from previous studies, and low near-surface velocities are associated with faults and fumarole locations. A sharp increase in velocity from < 1500 to > 2000 m/s at approximately 50 m below the ground surface in many parts of the study area may indicate a shallower water table than expected for the region.

15 GEOTHERMAL ENERGY↗

Preliminary Phase Field Computational Model Development

This interim report presents progress towards the development of meso-scale models of magnetic behavior that incorporate microstructural information. Modeling magnetic signatures in irradiated materials with complex microstructures (such as structural steels) is a significant challenge. The complexity is addressed incrementally, using the monocrystalline Fe (i.e., ferrite) film as model systems to develop and validate initial models, followed by polycrystalline Fe films, and by more complicated and representative alloys. In addition, the modeling incrementally addresses inclusion of other major phases (e.g., martensite, austenite), minor magnetic phases (e.g., carbides, FeCr precipitates), and minor nonmagnetic phases (e.g., Cu precipitates, voids). The focus of the magnetic modeling is on phase-field models. The models are based on the numerical solution to the Landau-Lifshitz-Gilbert equation. From the computational standpoint, phase-field modeling allows the simulation of large enough systems that relevant defect structures and their effects on functional properties like magnetism can be simulated. To date, two phase-field models have been generated in support of this work. First, a bulk iron model with periodic boundary conditions was generated as a proof-of-concept to investigate major loop effects of single versus polycrystalline bulk iron and effects of single non-magnetic defects. More recently, to support the experimental program herein using iron thin films, a new model was generated that uses finite boundary conditions representing surfaces and edges. This model has provided key insights into the domain structures observed in magnetic force microscopy (MFM) measurements. Simulation results for single crystal thin-film iron indicate the feasibility of the model for determining magnetic domain wall thickness and mobility in an externally applied field. Because the phase-field model dimensions are limited relative to the size of most specimens used in experiments, special experimental methods were devised to create similar boundary conditions in the iron films. Preliminary MFM studies conducted on single and polycrystalline iron films with small sub-areas created with focused ion beam have correlated quite well qualitatively with phase-field simulations. However, phase-field model dimensions are still small relative to experiments thus far. We are in the process of increasing the size of the models and decreasing specimen size so both have identical dimensions. Ongoing research is focused on validation of the phase-field model. Validation is being accomplished through comparison with experimentally obtained MFM images (in progress), and planned measurements of major hysteresis loops and first order reversal curves. Extrapolation of simulation sizes to represent a more stochastic bulk-like system will require sampling of various simulations (i.e., with single non-magnetic defect, single magnetic defect, single grain boundary, single dislocation, etc.) with distributions of input parameters. These outputs can then be compared to laboratory magnetic measurements and ultimately to simulate magnetic Barkhausen noise signals.

36 MATERIALS SCIENCE↗

NToF QCD 2ω FIDU Injection

During a National Ignition Facility (NIF) implosion, neutrons are released due to the fusion reactions between deuterium and tritium (DT) as well as between two deuterons (DD). The Neutron Time-of-Flight (NToF) diagnostic measures the arrival time and quantity of the neutrons that interact with the diagnostic’s Quartz Cherenkov Emitter. The neutron energy spectrum collected along multiple lines-of-sight (LOS) provides insight on the amount of energy absorbed and the bulk velocity of the hot spot of the implosion. The fiducial signal (FIDU) is used to determine the time the lasers are fired. This is used to determine the zero time for calculations of the neutron time of flight. Currently, the FIDU starts as an optical signal, is converted to an electrical signal, and then passes through a splitter. The electrical FIDU signal is then combined with the detector signal and read by the digitizer to be plotted on the same time scale. With the existing design, the Quartz Cherenkov Detector (QCD) is able to identify when the gamma rays reach the detector, but still relies on the FIDU input to the ADQ7 digitizer to determine the time the lasers are fired. The current FIDU signal limits the precision of the overall NToF measurement due to poor quality of signal. The QCD and FIDU signals coming together at the ADQ7 causes signals reflections, and the electrical splitters cause signal noise.

43 PARTICLE ACCELERATORS↗

Advanced Downhole Acoustic Sensing for Wellbore Integrity (Final Report)

Borehole cement is used across the range of energy technologies to stabilize casing, to serve as a barrier to behind-casing fluid movement. Cement debonding and other flaws, both at cement interfaces and within the cement itself, can create leakage pathways that can threaten safety to personnel, and wellbore performance, with economic and regulatory consequences. A primary method to assess cement health and wellbore integrity is via acoustic methods. This project was designed with three aims: demonstrate a significant improvement in the interpretation of cement acoustic behavior, both during curing, and in interpreting effects of flaws and evolving interfaces; develop sensor technologies to improve signal-noise ratios and cement acoustic responses; and lastly, provide a borehole demonstration of at least one of these technologies. We have accomplished the first two objectives, and the third, delayed by pandemic health concerns, is proceeding as of this writing via a technology partner with the University of Texas Advanced Energy Consortium.

15 GEOTHERMAL ENERGY↗

Hunting Sub-GeV Dark Matter with Diamonds and Magnetic Microcalorimeters Principle

This project is to study feasibility of a new concept for the sub-GeV dark matter (DM) detection using diamond crystals and magnetic microcalorimeters (MMCs). Diamond crystals are made of low mass carbon constituent that maximize kinetic energy of nuclear recoils from sub-GeV DM scattering due to their relatively similar masses. MMC is employed as a sensitive phonon sensor to measure athermal phonons that are produced by DM scattering in diamond crystals with 100 ns timing resolution and ~10 eV energy resolution. MMC’s fast timing resolution allows high precision phonon pulse shape analysis to separate out unwanted background or noise signals in the low energy region at E < 1 keV. Especially, the low energy excess (LEE) problems have been reported in the dark matter detection community and the proposed diamond-MMC detector might be able to provide important information to understand the origins of LEE signals in DM detectors. In this project a diamond-MMC detector has been built for proof-of-concept experiments and athermal phonon collection efficiencies have been investigated for single crystal and poly-crystal chemical-vapour-diamonds (SC and PC CVDs) as well as reference sapphire crystals are tested in the same geometries to quatify athermal phonon propagation and their collection to the MMC phonon sensors. Athermal phonon collection efficiencies and their lifetime in the diamond and sapphire crystals are successfully measured in the same geometry and experimental setup for comparison. SC CVD crystals exhibit poorer performance than the sapphire reference crystals in athermal phonon collection, while the PC CVD crystal exhibit better result than the sapphire. PC CVD with MMC phonon sensors would be feasible for sub GeV DM detection.

72 PHYSICS OF ELEMENTARY PARTICLES AND FIELDS↗

Conversion of METL Diagnostic Flowmeters to Permanent Magnet Based Electromagnetic Flowmeters

The Mechanisms Engineering Test Loop (METL) uses three flowmeters to monitor sodium circulation through the main loop, the Cold Trap leg, and the Plugging Meter leg. When constructed, the Cold Trap flowmeter (CTFM) and Plugging Meter flowmeter (PMFM) were equipped with permanent magnets and Hall Sensors. By October of 2019, during normal operations, both the CTFM and PMFM failed, producing either erroneous or zero signals. Repairs to the flowmeters were attempted in January of 2020 but failed to resolve the issues. Therefore, starting in March of 2021, a plan was developed to convert the installed flowmeters to more robust permanent magnet based electromagnetic flowmeters (EMFMs). The Cold Trap EMFM (CT EMFM) and Plugging Meter EMFM (PM EMFM) were fully installed by August of 2021. Initial testing and commissioning were completed in November of 2021. Finally, the first calibration runs were finished in March of 2022. This report discusses the design, conversion, and calibration of the as-built CTFM and PMFM to robust permanent magnet based EMFMs. During the design phase, theoretical models were used to estimate the signal output and required magnet sizes. Then, the CTFM and PMFM were disassembled and converted to EMFMs. After commissioning, the CT EMFM and PM EMFM were calibrated using a ‘Time Transfer Procedure’ carried out with METL Expansion Vessels and Test Vessel Two. The accuracy of the calibration was estimated through an uncertainty analysis. Finally, the report describes some lessons learned for future flowmeter conversions and follow-up work. In total, both METL EMFM’s met the desired performance targets. Testing data showed that the METL EMFMs provide a output signal of roughly 2 mV at 1 GPM and 250 °C. During calibration, flowrates between 0.7 GPM and 2.4 GPM were achieved. In this flow range, calibration coefficients of 0.485 and 0.935 were measured as with errors ranging from 15-5% and 16-5% for the CT EMFM and PM EMFM, respectively. Above 1.5 GPM, the error was assumed to be about 5% for both METL EMFMs. Several points will be considered for future follow-up work on the METL EMFM’s. First, the signal noise issues in the PM EMFM will be addressed. It is likely the source of the noise is due to some stray EMF from a heater. Secondly, the NdFeB magnets will be replaced with a grade that has a Curie temperature above 80 °C. For example, a few grades of NeFeB magnets have Curie temperatures which exceed 150 °C and some SmCo magnets have Curie temperatures as high as 500 °C. Third, more calibration runs will be completed in the range of 0.5-2.5 GPM. This will further improve the accuracy of the calibration coefficient. Fourth, calibration runs will be completed up to 5 GPM. This requires a larger pressure relief valve to be installed on the Expansion Vessel and Test Vessel 2, as well as a revised calibration procedure. Lastly, calibration runs will be completed to account for cold spots in the system, which reduced the inlet temperature of the METL EMFMs. Overall, these points will improve the calibration coefficients derived in this work and also improve the performance of the METL EMFMs.

42 ENGINEERING↗