Engineering Papers⌕ Search

SEARCH · Engineering Papers

Results for “SEM”

Search indexed NASA NTRS and DOE OSTI research on propulsion, heat transfer, battery materials and energy systems. Follow report and document links to the original sources.

Quote a phrase for an exact phrase match. Source license links do not imply unrestricted reuse.

At least 433 records · Page 24

SU-E-T-509: Inter-Observer and Inter-Modality Contouring Analysis for Organs at Risk for HDR Gynecological Brachytherapy

Purpose This study quantifies errors associated with MR-guided High Dose Rate (HDR) gynecological brachytherapy. Uncertainties in this treatment results from contouring, organ motion between imaging and treatment delivery, dose calculation, and dose delivery. We focus on interobserver and inter-modality variability in contouring and the motion of organs at risk (OARs) in the time span between the MR and CT scans (∼1 hour). We report the change in organ volume and position of center of mass (CM) between the two imaging modalities. Methods A total of 8 patients treated with MR-guided HDR brachytherapy were included in this study. Two observers contoured the bladder and rectum on both MR and CT scans. The change in OAR volume and CM position between the MR and CT imaging sessions on both image sets were calculated. Results The absolute mean bladder volume change between the two imaging modalities is 67.1cc. The absolute mean inter-observer difference in bladder volume is much lower at 15.5cc (MR) and 11.0cc (CT). This higher inter-modality volume difference suggests a real change in the bladder filling between the two imaging sessions. Change in Rectum volume inter-observer standard error of means (SEM) is 3.18cc (MR) and 3.09cc (CT), while the inter-modality SEM is 3.65cc (observer 1), and 2.75cc (observer 2). The SEM for rectum CM position in the superior-inferior direction was approximately three times higher than in other directions for both the inter—observer (0.77 cm, 0.92 cm for observers 1 and 2, respectively) and inter-modality (0.91 cm, 0.95 cm for MR and CT, respectively) variability. Conclusion Bladder contours display good consistency between different observers on both CT and MR images. For rectum contouring the highest inconsistency stems from the observers’ choice of the superior-inferior borders. A complete analysis of a larger patient cohort will enable us to separate the true organ motion from the inter-observer variability.

60 APPLIED LIFE SCIENCES↗

Magnetic-field-driven surface electromagnetic states in the graphene-antiferromagnetic photonic crystal system

The surface electromagnetic states (SEMSs) on graphene, which has a linear carrier dispersion law and is placed in an antiferromagnetic photonic crystal, are theoretically studied in the terahertz frequency range. The unit cell of such a crystal consists of layers of a nonmagnetic insulator and a uniaxial antiferromagnet, the easy axis of which is parallel to the crystal layers. A dc magnetic field is parallel to the easy axis of the antiferromagnet. An expression that relates the SEMS frequencies to the structure parameters is obtained. The problem of SEMS excitation by an external TE-polarized electromagnetic wave is solved, and the dependences of the transmission coefficient on the dc magnetic field and the carrier concentration are constructed. These dependences are shown to differ substantially from the case of a conventional two-dimensional electron gas with a quadratic electron dispersion law. Thus, the positions of the transmission coefficient peaks related to resonance SEMS excitation can be used to determine the character of carrier dispersion law in a two-dimensional electron gas.

75 CONDENSED MATTER PHYSICS, SUPERCONDUCTIVITY AND↗

AutoEMX v1.

The invention consists in the full automation of compositional analysis of inorganic powder samples by scanning electron microscopy (SEM) with energy-dispersive X-ray spectroscopy (EDS). The measurements and analysis are controlled via python-based software, Auto-SEMEDS. Auto-SEMEDS fully automates the SEM-EDS measurements, and analyses the collected data via the use of machine-learning (ML) algorithms, which have never been used before for such scope. Auto-SEMEDS enables the identification in fully-automated fashion of the individual material phases present in a powder sample. Similar technologies, such as commercial SEM-EDS software, can automatically classify particles based on their composition, but they have significant limitations. These solutions typically provide inaccurate composition measurements and struggle to identify single phases in lab samples, where phases are often closely intermixed. In contrast, Auto-SEMEDS achieves unprecedented accuracy in composition measurements of powder samples, and furthermore leverages machine learning algorithms to effectively discern intermixed phases. Notably, while previous studies have demonstrated accurate measurements on individual particles, Auto-SEMEDS stands out by successfully analyzing mixture of different phases, a capability that has not been reported in the literature until now.

Giunto, Andrea [Lawrence Berkeley National Laborat↗

Quantitating morphological changes in biological samples during scanning electron microscopy sample preparation with correlative super-resolution microscopy

Sample preparation is critical to biological electron microscopy (EM), and there have been continuous efforts on optimizing the procedures to best preserve structures of interest in the sample. However, a quantitative characterization of the morphological changes associated with each step in EM sample preparation is currently lacking. Using correlative EM and superresolution microscopy (SRM), we have examined the effects of different drying methods as well as osmium tetroxide (OsO 4 ) post-fixation on cell morphology during scanning electron microscopy (SEM) sample preparation. Here, SRM images of the sample acquired under hydrated conditions were used as a baseline for evaluating morphological changes as the sample went through SEM sample processing. We found that both chemical drying and critical point drying lead to a mild cellular boundary retraction of ~60 nm. Post-fixation by OsO 4 causes at least 40 nm additional boundary retraction. We also found that coating coverslips with adhesion molecules such as fibronectin prior to cell plating helps reduce cell distortion from OsO 4 post-fixation. These quantitative measurements offer useful information for identifying causes of cell distortions in SEM sample preparation and improving current procedures.

59 BASIC BIOLOGICAL SCIENCES↗

Core-flood Effluent and Shale Surface Chemistries in Predicting Interaction between Shale, Brine, and Reactive Fluid

We report field and laboratory observations to date indicate that the efficiency of hydraulic fracturing, as it relates to hydrocarbon recovery, depends significantly on geochemical alterations to rock surfaces that diminish accessibility by partial or total plugging of the pore and fracture networks. This is caused by mineral scale deposition such as coating of fracture surfaces with precipitates, particle migration, and/or crack closure due to dissolution under stress. In reactive flow-through experiments, mineral reactions in response to acidic fluid injection significantly reduced system porosity and core permeability. The present study focuses on changes to fluid chemistry and shale surfaces (inlet and fracture walls) resulting from shale-fluid interactions and integrating these findings for an improved estimate of transport-related consequences. The reacted shale surfaces were examined by spatially-resolved scanning electron microscopy - energy dispersive spectroscopy (SEM-EDS) analysis. Importantly, inductively coupled plasma - mass spectrometry/optical emission spectroscopy (ICP-MS/OES) was utilized to probe the chemical evolution of the core-flood effluents. The three study cores selected from the Marcellus formation represent different mineralogies and structural features. In flow-through experiments, lab-generated brine and HCl-based fracture fluid (pH=2) were injected sequentially under effective stress (up to 500 psi) at reservoir temperature (80°C). SEM-EDS results confirmed by the ICP concentration trends showed significant Fe hydroxide precipitates in clay- and pyrite-rich outcrop samples due to partial oxidation of Fe-bearing phases in the case of intrusion of low salinity water-based fluids. Porosity reduction in the MSEEL (Marcellus Shale Energy and Environmental Laboratory) carbonate-rich sample is related to compaction of cores under stress due to matrix softening with substantial dissolution, and pore-filling by hydroxides, as well as barite and salts. Despite the same fluid compositions and experimental conditions used for both MSEEL samples, barite precipitation was much more intense in the MSEEL clay-rich sample due to its greater sorption capacity and additional sulfate source as well as fissile nature with multiple lengthwise cracks. ICP tests revealed time-resolved concentration trends in produced brine and reactive fluids that in turn complemented the pre-/post-reaction SEM-EDS observations.

37 INORGANIC, ORGANIC, PHYSICAL, AND ANALYTICAL CH↗

Noble gas ion beams in materials science for future applications and devices

Helium ion microscopy (HIM), enabled by a gas field ion source (GFIS), is an emerging imaging and nanofabrication technique compatible with many applications in materials science. The scanning electron microscope (SEM) has become ubiquitous in materials science for high-resolution imaging of materials. However, due to the fundamental limitation in focusing of electron beams, ion-beam microscopy is now being developed (e.g., at 20 kV the SEM beam diameter ranges from 0.5 to 1 nm, whereas the HIM offers 0.35 nm). The key technological advantage of the HIM is in its multipurpose design that excels in a variety of disciplines. The HIM offers higher resolution than the best available SEMs as well as the traditional gallium liquid-metal ion source (LMISs) focused ion beams (FIBs), and is capable of imaging untreated biological or other insulating samples with unprecedented resolution, depth of field, materials contrast, and image quality. GFIS FIBs also offer a direct path to defect engineering via ion implantation, three-dimensional direct write using gaseous and liquid precursors, and chemical-imaging options with secondary ion mass spectrometry. HIM covers a wide range of tasks that otherwise would require multiple tools or specialized sample preparation. In this paper, we describe the underlying technology, present materials, relevant applications, and offer an outlook for the potential of FIB technology in processing materials.

2D materials↗

Technetium Waste Form Development – Progress Report

The approach being followed to evaluate the use of an iron-based alloy waste form to immobilize the Tc-bearing waste streams generated during the aqueous and electrochemical processing of used fuel that is being studied in the DOE Advanced Fuel Cycle Initiative (AFCI) is presented in this report. The objective is to develop an alloy waste form that provides high waste loading within waste form processing limitations, meets waste form performance requirements for durability and the long-term retention of radionuclides, and can be produced with consistent physical, chemical, and radiological properties that meet regulatory acceptance requirements for disposal. Microanalysis using scanning electron microscopy (SEM) and transmission electron microscopy (TEM) was used to analyze non-radioactive Fe-Mo-Re samples. A sample was prepared for SEM; however, significant unforeseen instrument problems led to delays in conducting the detailed work. The TEM was not available for this particular sample and therefore only preliminary SEM work can be reported. The results are in agreement with previous studies [Ebert 2009]; however, a rhenium-rich region within the Re-Mo phase is clearly visible.

12 MANAGEMENT OF RADIOACTIVE AND NON-RADIOACTIVE W↗

Fabrication of Pd/Pd-Alloy Films by Surfactant Induced Electroless Plating for Hydrogen Separation from Advanced Coal Gasification Processes

Dense Pd, Pd-Cu and Pd-Ag composite membranes on microporous stainless steel substrate (MPSS) were fabricated by a novel electroless plating (EP) process. In the conventional Pd-EP process, the oxidation-reduction reactions between Pd-complex and hydrazine result in an evolution of NH 3 and N 2 gas bubbles. When adhered to the substrate surface and in the pores, these gas bubbles hinder uniform Pd-film deposition which results in dendrite growth leading to poor film formation. This problem was addressed by introducing cationic surfactant in the electroless plating process known as surfactant induced electroless plating (SIEP). The unique features of this innovation provide control of Pd-deposition rate, and Pd-grain size distribution. The surfactant molecules play an important role in the EP process by tailoring grain size and the process of agglomeration by removing tiny gas bubbles through adsorption at the gas-liquid interface. As a result surfactant can tailor a nanocrystalline Pd, Cu and Ag deposition in the film resulting in reduced membrane film thickness. Also, it produces a uniform, agglomerated film structure. The Pd-Cu and Pd-Ag membranes on MPSS support were fabricated by sequential deposition using SIEP method. The pre- and post-annealing characterizations of these membranes (Pd, Pd-Cu and Pd-Ag on MPSS substrate) were carried out by SEM, EDX, XRD, and AFM studies. The SEM images show significant improvement of the membrane surface morphology, in terms of metal grain structures and grain agglomeration compared to the membranes fabricated by conventional EP process. The SEM images and helium gas-tightness studies indicate that dense and thinner films of Pd, Pd-Cu and Pd-Ag membranes can be produced with shorter deposition time using surfactant. H 2 Flux through the membranes fabricated by SIEP shows large improvement compared to those by CEP with comparable permselectivity. Pd-MPSS composite membrane was subjected to test for long term performance and thermal cycling (573 - 723 - 573 K) at 15 psi pressure drop for 1200 hours. Pd membranes showed excellent hydrogen permeability and thermal stability during the operational period. Under thermal cycling (573 K - 873 K - 573 K), Pd-Cu-MPSS membrane was stable and retained hydrogen permeation characteristics for over three months of operation. From this limited study, we conclude that SIEP is viable method for fabrication of defect-free, robust Pd-alloy membranes for high-temperature H 2 -separation applications.

08 HYDROGEN↗

Solid Phase Characterization of Tank 241-C-108 Residual Waste Solids Samples

This report presents the results for solid phase characterization (SPC) of solid samples removed from tank 241-C-108 (C-108) on August 12-13,2012, using the off-riser sampler. Samples were received at the 222-S Laboratory on August 13 and were described and photographed. The SPC analyses that were performed include scanning electron microscopy (SEM) using the ASPEX(R)l scanning electron microscope, X-ray diffraction (XRD) using the Rigaku(R) 2 MiniFlex X-ray diffractometer, and polarized light microscopy (PLM) using the Nikon(R) 3 Eclipse Pol optical microscope. The SEM is equipped with an energy dispersive X-ray spectrometer (EDS) to provide chemical information. Gary A. Cooke conducted the SEM analysis, John A. Pestovich performed the XRD analysis, and Dr. Heinz J. Huber performed the PLM examination. The results of these analyses are presented here.

12 MANAGEMENT OF RADIOACTIVE AND NON-RADIOACTIVE W↗

Mirror monochromator

In this SBIR project, Electron Optica, Inc. (EOI) is developing a mirror electron monochromator (MirrorChrom) attachment to new and retrofitted electron microscopes (EMs) for improving the energy resolution of the EM from the characteristic range of 0.2-0.5 eV to the range of 10-50 meV. This improvement will enhance the characterization of materials by imaging and spectroscopy. In particular, the monochromator will refine the energy spectra characterizing materials, as obtained from transmission EMs [TEMs] fitted with electron spectrometers, and it will increase the spatial resolution of the images of materials taken with scanning EMs (SEMs) operated at low voltages. EOI’s MirrorChrom technology utilizes a magnetic prism to simultaneously deflect the electron beam off the axis of the microscope column by 90° and disperse the electrons in proportional to their energies into a module with an electron mirror and a knife-edge. The knife-edge cuts off the tails of the energy distribution to reduce the energy spread of the electrons that are reflected, and subsequently deflected, back into the microscope column. The knife-edge is less prone to contamination, and thereby charging, than the conventional slits used in existing monochromators, which improves the reliability and stability of the module. The overall design of the MirrorChrom exploits the symmetry inherent in reversing the electron trajectory in order to maintain the beam brightness – a parameter that impacts how well the electron beam can be focused downstream onto a sample. During phase I, EOI drafted a set of candidate monochromator architectures and evaluated the trade-offs between energy resolution and beam current to achieve the optimum design for three particular applications with market potential: increasing the spatial resolution of low voltage SEMs, increasing the energy resolution of low voltage TEMs (beam energy of 5-20 keV), and increasing the energy resolution of conventional TEMs (beam energy of 80-120 keV). Specialized software packages that have been developed by MEBS, Ltd. were used to calculate the electron optical properties of the key monochromator components: namely, the magnetic prism, the electron mirror, and the electron lenses. In the final step, these results were folded into a model describing the key electron-optical parameters of the complete monochromator. The simulations reveal that the mirror monochromator can reduce the energy spread of a Schottky electron source, an established electron emitter used widely in EMs, to 10 meV for practical beam current values and that further reduction of the energy spread down to 3 meV is possible for low current applications with a Cold Field Emitter (an electron source with 10x the brightness of a Schottky source). MirrorChroms can be designed and built to attach to different types of TEMs and SEMs, thus making them suitable for enhancing the study of the structure, composition, and bonding states of new materials at the nanoscale to advance material science research in the field of nanotechnology as well as biomedical research.

46 INSTRUMENTATION RELATED TO NUCLEAR SCIENCE AND ↗

Documentation of operational protocol for the use of MAMA software

Image analysis of Scanning Electron Microscope (SEM) micrographs is a complex process that can vary significantly between analysts. The factors causing the variation are numerous, and the purpose of Task 2b is to develop and test a set of protocols designed to minimize variation in image analysis between different analysts and laboratories, specifically using the MAMA software package, Version 2.1. The protocols were designed to be “minimally invasive”, so that expert SEM operators will not be overly constrained in the way they analyze particle samples. The protocols will be tested using a round-robin approach where results from expert SEM users at Los Alamos National Laboratory, Lawrence Livermore National Laboratory, Pacific Northwest National Laboratory, Savannah River National Laboratory, and the National Institute of Standards and Testing will be compared. The variation of the results will be used to quantify uncertainty in the particle image analysis process. The round-robin exercise will proceed with 3 levels of rigor, each with their own set of protocols, as described below in Tasks 2b.1, 2b.2, and 2b.3. The uncertainty will be developed using NIST standard reference material SRM 1984 “Thermal Spray Powder – Particle Size Distribution, Tungsten Carbide/Cobalt (Acicular)” [Reference 1]. Full details are available in the Certificate of Analysis, posted on the NIST website (http://www.nist.gov/srm/).

97 MATHEMATICS AND COMPUTING↗

Dealloying, Microstructure and the Corrosion/Protection of Cast Magnesium Alloys

The purpose of this project was to develop a greater understanding of micro-galvanic corrosion effects in cast magnesium alloys using both experimental and computational methods. Experimental accomplishments have been made in the following areas of interest: characterization, aqueous free-corrosion, atmospheric corrosion, ionic liquid dissolution, rate kinetics of oxide dissolution, and coating investigation. Commercial alloys (AZ91D, AM60, and AZ31B), binary-phase alloys (αMg-2at.%Al, αMg-5at.%Al, and Mg-8at.%Al), and component phases (Mg, Al, β-Mg, β-1%Zn, MnAl3) were obtained and characterized using energy dispersive spectroscopy (EDS), X-ray diffraction (XRD), and scanning electron microscopy (SEM). Full immersion in aqueous chloride was used to characterize the corrosion behavior of alloys. Rotating disc electrodes (RDEs) were used to observe accelerated long-term corrosion behavior. Al surface redistribution for freely corroded samples was analyzed using SEM, EDS, and lithium underpotential deposition (Li UPD). Atmospheric corrosion was observed using contact angle evolution, overnight pH monitoring, and surface pH evolution studies. Ionic liquid corrosion characterization was performed using linear sweep voltammetry and potentiostatic dissolution in 150° choline chloride-urea (cc-urea). Two surface coatings were investigated: (1) Li-carbonate and (2) cc-urea. Li-carbonate coatings were characterized using X-ray photoelectron spectroscopy (XPS), SEM, and aqueous free corrosion potential monitoring. Hydrophobic cc-urea coatings were characterized using contact angle measurements and electrochemical impedance spectroscopy. Oxide dissolution rate kinetics were studied using inductively coupled plasma mass spectroscopy (ICP-MS). Computational accomplishments have been made through the development of Kinetic Monte Carlo (KMC) simulations which model time- and composition-dependent effects on the microstructure due to spatial redistribution of alloying elements during corrosion.

36 MATERIALS SCIENCE↗

Improved Characterization and Modeling of Tight Oil Formations for CO 2 Enhanced Oil Recovery Potential and Storage Capacity Estimation

Tight oil formations such as those in the Bakken petroleum system are known to hold hundreds of billions of barrels of oil in place; however, the primary recovery factor for these plays is typically less than 10%. Tight oil formations, including the Bakken Formation, therefore, may be attractive candidates for enhanced oil recovery (EOR) using CO 2 . Multiphase fluid behavior and flow in fluid-rich shales can vary substantially depending on the size of pore throats, and properties such as fluid viscosity and density are much different in nanoscale pores than in macroscale pores. Thus it is critical to understand the nature and distribution of nano-, micro-, and macroscale pores and fracture networks. To address these issues, the Energy & Environmental Research Center (EERC) has been conducting a research program entitled “Improved Characterization and Modeling of Tight Oil Formations for CO 2 Enhanced Oil Recovery Potential and Storage Capacity Estimation.” The objectives of the project are 1) the use of advanced characterization methods to better understand and quantify the petrophysical and geomechanical factors that control CO 2 and oil mobility within tight oil formation samples, 2) the determination of CO 2 permeation and oil extraction rates in tight reservoir rocks and organic-rich shales of the Bakken, and 3) the integration of the laboratory-based CO 2 permeation and oil extraction data and the characterization data into geologic models and dynamic simulations to develop predictions of CO 2 storage resource and EOR in the Bakken tight oil formation. A combination of standard and advanced petrophysical characterization techniques were applied to characterize samples of Bakken Formation tight reservoir rock and shales from multiple wells. Techniques included advanced computer tomography (CT) imaging, scanning electron microscopy (SEM) techniques, whole-core and micro x-ray CT imaging, field emission (FE) SEM, and focused ion beam (FIB) SEM. Selected samples were also analyzed for geomechanical properties. X-ray CT imaging yielded information on the occurrence of fractures, bedding planes, fossils, and bioturbation in core, as well as data on bulk density and photoelectric factor logs, which were used to interpret porosity, organic content, and mineralogy. FESEM was used for characterization of nano- and microscale features, including nanoscale pore visualization and micropore and pore throat mineralogy. FIBSEM yielded micro- to nanoscale visualization of fracture networks, porosity and pore-size distribution, connected versus isolated porosity, and distribution of organics. Results from the characterization activities provide insight on nanoscale fracture properties, pore throat mineralogy and connectivity, rock matrix characteristics, mineralogy, and organic content. Laboratory experiments demonstrated that CO 2 can permeate the tight matrix of Bakken shale and nonshale reservoir samples and mobilize oil from those samples. Geologic models were created at scales ranging from the core plug to the reservoir, and dynamic simulations were conducted. The data from the characterization and laboratory-based activities were integrated into modeling research activities to determine the fundamental mechanisms controlling fluid transport in the Bakken, which support EOR scheme design and estimation of CO 2 storage potential in tight oil formations. Simulation results suggest a CO 2 storage resource estimate range of 169 million to 1.5 billion tonnes for the Bakken in North Dakota, possibly resulting in 1.8 billion to 16 billion barrels of incremental oil.

04 OIL SHALES AND TAR SANDS↗

Analysis of Defects in Metal Additive Manufacturing with Augmented Data Generation

Laser powder bed fusion (LPBF) is a method of additive manufacturing (AM) that selectively melts and fuses together microscopic metallic powder. LPBF offers the benefit of producing custom structures out of high strength metals that can be difficult to fabricate with conventional methods. The challenge of LPBF is that 3D printed structures often have internal pores due to process flaws. Pulsed thermal tomography (PTT) is a method for reconstructing the depth profile of materials, allowing the visualization internal voids in solids. In prior work, we developed a convolutional neural network (CNN) which, having been trained on simulated 2D PTT images of subsurface elliptical defects, was able to classify the semi-major radii, semi-minor radii, and angular orientation of the best-fit ellipses in previously unseen PTT images. The unseen PTT images contained subsurface irregular defect shapes imported from scanning electron microscopy (SEM) images of metallic LPBF-printed specimens. Training the CNN on irregular defect shapes instead of on elliptical shapes would make the resulting classifications more descriptive of actual defect shapes. However, this requires a much higher volume of SEM images of material defects, which are difficult to obtain because of random occurrence of defects in LPBF. To address this challenge, we developed a generative adversarial network (GAN) to augment the existing dataset of SEM defect images. The GAN model is demonstrated to create novel yet realistic defect shapes that can be used as input for simulated PTT images to train CNN.

36 MATERIALS SCIENCE↗

Pulsed Thermal Tomography Nondestructive Examination of Additively Manufactured Reactor Materials and Components (Final Technical Report)

Metal Additive Manufacturing (AM) is a promising method for cost-efficient fabrication of complex shape structures for applications in harsh environment, such as in a nuclear reactor. However, internal defects (pores) occur in high-strength AM alloys, which are manufactured with Laser Powder Bed Fusion (LPBF) AM method. Pulsed Infrared Thermography (PIT) is an efficient nondestructive evaluation (NDE) method to examine actual structures, because this method offers one-sided non-contact measurements, and fast processing of large sample areas. However, imaging of material defects, particularly defects with sizes at microscopic level, is challenging. In this report, we benchmark the performance of several Unsupervised Learning (UL) algorithms designed to enhance imaging of microscopic defects in metals with PIT. UL aims to learn the latent principal patterns (dictionaries) in PIT data to detect defects with minimal human supervision. Performance of Independent Component Analysis (ICA), Sparse Coding (SC), Principal Component Analysis (PCA) and Exploratory Factor Analysis (EFA) was compared using F-score, UL model training time and defects reconstruction time. We obtained the average F-score of 0.75, and a highest F-score of 0.89 for the EFA algorithm. Overall, EFA outperforms other UL algorithms considered in this study. In another approach, we investigate Thermal Tomography (TT), which is a computational method for reconstruction of depth profile of internal material defects from PIT nondestructive evaluation (NDE). TT algorithm obtains depth reconstructions of thermal effusivity, which has been shown to provide visualization of subsurface internals defects in metals. In many applications, one needs to determine the defect shape and orientation from reconstructed effusivity images. Interpretation of TT images is non-trivial because of blurring, which increases with depth due to heat diffusion-based nature of image formation. We have developed a deep learning convolutional neural network (CNN) to classify size and orientation of subsurface material defects in TT images. CNN was trained with TT images produced with computer simulations of 2D metallic structures (thin plates) containing elliptical subsurface voids. Performance of CNN was investigated using test TT images developed with computer simulations of plates containing elliptical defects, and defects with shape imported from scanning electron microscopy (SEM) images. CNN demonstrated the ability to classify radii and angular orientation of elliptical defects in previously unseen test TT images. We have also demonstrated that CNN trained on TT images of elliptical defects is capable of classifying shape and orientation of irregular defects. Training the CNN on irregular defect shapes instead of on elliptical shapes would make the resulting classifications more descriptive of actual defect shapes. However, this requires a much higher volume of SEM images of material defects, which are difficult to obtain because of random occurrence of defects in LPBF. To address this challenge, we developed a generative adversarial network (GAN) to augment the existing dataset of SEM defect images. The GAN model is demonstrated to create novel yet realistic defect shapes that can be used as input for simulated PTT images to train CNN. We also investigate several approaches based on Gaussian Random Circle and Bezier Curves for constructing parametric models of irregular-shape defects.

36 MATERIALS SCIENCE↗

Multidimensional Diagnostics of the Interface Evolutions in Solid-State Lithium Batteries

All-solid-state lithium metal batteries hold tremendous potential as next-generation energy storage solutions. However, their performance is hindered by complex chemo-mechanical instabilities at the interface, which encompass electrolyte decomposition, loss of contact due to volume changes, and the growth of lithium filaments. Given the complexity of these failure mechanisms, it is imperative to employ multidimensional diagnostics that leverage a combination of tools capable of quantifying formed voids and filaments, identifying the chemical and mechanical properties of lithium dendrites and electrolyte decomposition products, as well as monitoring the evolution of these processes in situ. The primary objective of this project is to develop a comprehensive characterization platform for solid-state battery interfaces, integrating FIB-SEM tomography, ToF-SIMS, in-SEM nanoindentation, and in-SIMS AFM-based stiffness mapping to enable structural, chemical, and mechanical analyses. The project team has accomplished significant milestones, including: 1) The successful development of a characterization platform that combines FIB-SEM, ToF-SIMS, nanoindentation, and AFM. 2) The creation of solid-state cells at various scales. 3) Real-time visualization of the plating and stripping of lithium. 4) Operando analysis of the chemical composition and evolution of electrolyte decomposition products, encompassing intermediate and metastable species, at both the cathode and anode interfaces. 5) In situ analysis of mechanical properties coupled with chemical mapping. 6) The implementation of the multiscale characterization technique has yielded valuable insights into cell failure mechanisms and has led to the development of a solid-state lithium cell that exhibits exceptional durability, surpassing 2500 cycles. This project has resulted in 10 publications, 1 invention disclosure, 8 manuscripts under review or in preparation.

25 ENERGY STORAGE↗

Preserving Superconvergence of Spectral Elements for Curved Domains via $h$ and $p$-Geometric Refinement

Spectral element methods (SEM), extensions of finite element methods (FEM), have emerged as significant techniques for solving partial differential equations in physics and engineering. SEM can potentially deliver superior accuracy due to the potential superconvergence in nodal solutions for well-shaped tensor-product elements. However, the accuracy of SEM often degrades in complex geometries due to geometric inaccuracies near curved boundaries and the loss of superconvergence with simplicial or non-tensor-product elements. To overcome the first issue, we propose using h- and p-geometric refinement, which refines the mesh near high-curvature regions and increases the degree of geometric basis functions, respectively. We show that when using mixed-element meshes with tensor-product elements in the interior of the domain, curvature-based geometric refinement near boundaries can improve the accuracy of the interior elements by reducing pollution errors and preserving the superconvergence in nodal solutions. To address the second issue, we introduce a post-processing technique using the adaptive extended stencil finite element method (AES-FEM) to recover the accuracy near the curved boundaries. The combination of curvature-based geometric refinement and accurate post-processing offers an effective and easier-to-implement alternative to methods reliant on exact geometries. We demonstrate our techniques by solving the convection-diffusion equation in 2D and show up to two orders of magnitude of improvement in the solution accuracy, even when the elements are poorly shaped near boundaries.

97 MATHEMATICS AND COMPUTING↗

Preserving Superconvergence of Spectral Elements for Curved Domains

Spectral element methods (SEM), extensions of finite element methods (FEM), have emerged as significant techniques for solving partial differential equations in physics and engineering. SEM can potentially deliver superior accuracy due to the potential superconvergence in nodal solutions for well-shaped tensor-product elements. However, the accuracy of SEM often degrades in complex geometries due to geometric inaccuracies near curved boundaries and the loss of superconvergence with simplicial or non-tensor-product elements. To overcome the first issue, we propose using geometric refinement, which both refines the mesh near high-curvature regions and increases the degree of geometric basis functions. We show that when using mixed-element meshes with tensor-product elements in the interior of the domain, curvature-based geometric refinement near boundaries can improve the accuracy of the interior elements by reducing pollution errors and preserving the superconvergence in nodal solutions. To address the second issue, we introduce ApSEM, a post-processing technique using the adaptive extended stencil finite element method (AES-FEM) to recover the accuracy near the curved boundaries. The combination of curvature-based geometric refinement and accurate post-processing offers an effective and easier-to-implement alternative to methods reliant on exact geometries. We demonstrate our techniques by solving the convection-diffusion equation in 2D and 3D and show up to two orders of magnitude of improvement in the solution accuracy, even when the elements are poorly shaped near boundaries. We also show the efficiency of ApSEM as it can recover superconvergence in nodal solutions without drastically increasing the computational cost.

97 MATHEMATICS AND COMPUTING↗