Engineering Papers⌕ Search

SEARCH · Engineering Papers

Results for “SCINTILLATION COUNTER”

Search indexed NASA NTRS and DOE OSTI research on propulsion, heat transfer, battery materials and energy systems. Follow report and document links to the original sources.

Quote a phrase for an exact phrase match. Source license links do not imply unrestricted reuse.

At least 433 records · Page 24

950 keV X-Band Linac For Material Recognition Using Two-Fold Scintillator Detector As A Concept Of Dual-Energy X-Ray System

One of the advantages of applying X-band linear accelerator (Linac) is the compact size of the whole system. That shows us the possibility of on-site system such as the custom inspection system in an airport. As X-ray source, we have developed X-band Linac and achieved maximum X-ray energy 950 keV using the low power magnetron (250 kW) in 2 {mu}s pulse length. The whole size of the Linac system is 1x1x1 m{sup 3}. That is realized by introducing X-band system. In addition, we have designed two-fold scintillator detector in dual energy X-ray concept. Monte carlo N-particle transport (MCNP) code was used to make up sensor part of the design with two scintillators, CsI and CdWO4. The custom inspection system is composed of two equipments: 950 keV X-band Linac and two-fold scintillator and they are operated simulating real situation such as baggage check in an airport. We will show you the results of experiment which was performed with metal samples: iron and lead as targets in several conditions.

43 PARTICLE ACCELERATORS↗

X-Ray Measurements Of A Thermo Scientific P385 DD Neutron Generator

Idaho National Laboratory is experimenting with electrical neutron generators, as potential replacements for californium-252 radioisotopic neutron sources in its PINS prompt gamma-ray neutron activation analysis (PGNAA) system for the identification of military chemical warfare agents and explosives. In addition to neutron output, we have recently measured the x-ray output of the Thermo Scientific P385 deuterium-deuterium neutron generator. X rays are a normal byproduct from neutron generators, but depending on their intensity and energy, x rays can interfere with gamma rays from the object under test, increase gamma-spectrometer dead time, and reduce PGNAA system throughput. The P385 x-ray energy spectrum was measured with a high-purity germanium (HPGe) detector, and a broad peak is evident at about 70 keV. To identify the source of the x rays within the neutron generator assembly, it was scanned by collimated scintillation detectors along its long axis. At the strongest x-ray emission points, the generator also was rotated 60 deg. between measurements. The scans show the primary source of x-ray emission from the P385 neutron generator is an area 60 mm from the neutron production target, in the vicinity of the ion source. Rotation of the neutron generator did not significantly alter the x-ray count rate, and its x-ray emission appears to be axially symmetric. A thin lead shield, 3.2 mm (1/8 inch) thick, reduced the 70-keV generator x rays to negligible levels.

46 INSTRUMENTATION RELATED TO NUCLEAR SCIENCE AND ↗

Multi-Channel Integrated Circuits For Use In Research With Radioactive Ion Beams

The Integrated Circuits Design Research Laboratory at Southern Illinois University Edwardsville (SIUE) has been collaborating over the past several years with the Nuclear Reactions Group at Washington University (WU) on the development of a family of custom, multi-channel Integrated Circuits (ICs). To date, the collaboration has successfully produced two micro-chips. The first was an analog shaped and peak sensing chip known as HINP16C (Heavy Ion Nuclear Physics--16 Channel). The second chip, christened PSD8C (Pulse Shape Discrimination--8 Channel), was designed to logically complement (in terms of detector types) the HINP16C chip. The HINP16C chip, for use with solid-state detectors, produces sparsified analog pulse trains for both linear (pulse height) and timing (relative to an external reference) signals. A shaper and peak detector are implemented in the linear branch, and a pseudo Constant-Fraction Discriminator (CFD) and Time-to-Voltage Converter (TVC) are implemented in the logic/timing branch. The internal and external gain options make the chip suitable for use in a wide variety of applications. PSD8C greatly simplifies the pulse-processing electronics needed for large arrays of scintillation detectors. As the PSD8C employs user-controlled, multi-region charge integration, particle identification is inherent in the design. Each of the three pulse-height sub-channels consists of a gated integrator with eight programmable charging rates and an externally programmable gate generator that defines the start (with 4 time ranges) and the width (with 4 time ranges) of the gate, relative to an external discriminator signal. Moreover, each channel on the chip also contains a TVC. This paper describes the design, capabilities, and features of the HINP16C and PSD8C ICs along with a description of how the chips are being used. It also discusses modifications and enhancements which have been made to both chips and their associated prototypical systems in order to improve ease of use and increase performance.

46 INSTRUMENTATION RELATED TO NUCLEAR SCIENCE AND ↗

A compact digital time differential perturbed angular correlation-spectrometer using field programmable gate arrays and various timestamp algorithms

A user-friendly fully digital time differential perturbed angular correlation (TDPAC)-spectrometer with six detectors and fast digitizers using field programmable gate arrays (FPGA) is described and performance data are given. The new spectrometer has an online data analysis feature, a compact size, and a time resolution such as conventional analog spectrometers. Its calculation intensive part was implemented inside the digitizer. This gives the possibility to change parameters (energy windows, constant fraction trigger delay) and see their influence immediately in the {gamma}-{gamma} correlation diagrams. Tests were performed which showed that the time resolution using a {sup 60}Co source with energy window set at 1.17 MeV and 1.33 MeV is 265 ps with LaBr{sub 3}(Ce) scintillators and 254 ps with BaF{sub 2} scintillators. A true constant fraction algorithm turned out to be slightly better than the constant fraction of amplitude method. The spectrometer performance was tested with a TDPAC measurement using a {sup 44}Ti in rutile source and a positron lifetime measurement using {sup 22}Na. The maximum possible data rate of the spectrometer is 1.1 x 10{sup 6} {gamma} quanta per detector and second.

46 INSTRUMENTATION RELATED TO NUCLEAR SCIENCE AND ↗

A transport-based model of material trends in nonproportionality of scintillators

Electron-hole pairs created by the passage of a high-energy electron in a scintillator radiation detector find themselves in a very high radial concentration gradient of the primary electron track. Since nonlinear quenching that is generally regarded to be at the root of nonproportional response depends on the fourth or sixth power of the track radius in a cylindrical track model, radial diffusion of charge carriers and excitons on the {approx}10 picosecond duration typical of nonlinear quenching can compete with and thereby modify that quenching. We use a numerical model of transport and nonlinear quenching to examine trends affecting local light yield versus excitation density as a function of charge carrier and exciton diffusion coefficients. Four trends are found: (1) nonlinear quenching associated with the universal 'roll-off' of local light yield versus dE/dx is a function of the lesser of mobilities {mu}{sub e} and {mu}{sub h} or of D{sub EXC} as appropriate, spanning a broad range of scintillators and semiconductor detectors; (2) when {mu}{sub e{approx_equal}{mu}h}, excitons dominate free carriers in transport, the corresponding reduction of scattering by charged defects and optical phonons increases diffusion out of the track in competition with nonlinear quenching, and a rise in proportionality is expected; (3) when {mu}{sub h} << {mu}{sub e} as in halide scintillators with hole self-trapping, the branching between free carriers and excitons varies strongly along the track, leading to a 'hump' in local light yield versus dE/dx; (4) anisotropic mobility can promote charge separation along orthogonal axes and leads to a characteristic shift of the 'hump' in halide local light yield. Trends 1 and 2 have been combined in a quantitative model of nonlinear local light yield which is predictive of empirical nonproportionality for a wide range of oxide and semiconductor radiation detector materials where band mass or mobility data are the determinative material parameters.

75 CONDENSED MATTER PHYSICS, SUPERCONDUCTIVITY AND↗

Commissioning of Angle Dispersive X-ray Diffraction Beamline on Indus-2

An Angle dispersive x-ray diffraction (ADXRD) beamline on bending magnet source of Indus-2 synchrotron (2.5 GeV, 300 mA) has been commissioned, for the study of single and polycrystalline samples. The beamline optics is based on vertically focusing Pt-coated pre and post mirrors and sagittal focusing Si (311) based double crystal monochromator. Experimental station consists of a six circle diffractometer equipped with scintillation detector and an image plate area detector for powder diffraction. XRD experiments have been performed to study single crystal and polycrystalline samples.

43 PARTICLE ACCELERATORS↗

New observations in the MiniBooNE experiment

The MiniBooNE neutrino oscillation search experiment at Fermilab has recently reported results from a search for microe oscillations, using a data sample corresponding to 5.66 x 1020 protons on target in anti-neutrino mode. The experiment is now se nsitive to the excess of microe events observed by Los Alamos Liquid Scintillator Neutrino Detector (LSND). MiniBooNE data are consistent with microe oscillations in the m2 range of 0.1 to 1.0 eV2 and with the evidence for antineutrino oscillations from L SND.

72 PHYSICS OF ELEMENTARY PARTICLES AND FIELDS↗

Physics Potential of a 2540 Km Baseline Superbeam Experiment

We study the physics potential of a neutrino superbeam experiment with a 2540 km baseline. We assume a neutrino beam similar to the NuMI beam in the medium energy configuration. We consider a 100 kton totally active scintillator detector at a 7 mr off-axis location. We find that such a configuration has an outstanding hierarchy discriminating capability. In conjunction with the data from the present reactor neutrino experiments, it can determine the neutrino mass hierarchy at the 3{sigma} level in less than 5 years, if sin{sup 2}2{theta}{sub 13}{>=}0.01, running in the neutrino mode alone. As a stand alone experiment, with a 5 year neutrino run and a 5 year anti-neutrino run, it can determine non-zero {theta}{sub 13} at the 3{sigma} level if sin{sup 2} 2{theta}{sub 13}{>=}7x10{sup -3} and hierarchy at the 3{sigma} level if sin{sup 2}2{theta}{sub 13}{>=}8x10{sup -3}. This data can also distinguish {delta}{sub CP} = {pi}/2 from the CP conserving values of 0 and {pi}, for sin{sup 2}2{theta}{sub 13}{>=}0.02.

72 PHYSICS OF ELEMENTARY PARTICLES AND FIELDS↗

Status of RENO Experiment

The RENO (Reactor Experiment for Neutrino Oscillation) experiment is under construction to measure the smallest neutrino mixing angle {theta}{sub 13} using anti-neutrinos emitted from the Yonggwang nuclear power plant in Korea. The experiment is planning to start data-taking in early 2011 with two identical 16-ton Gadolinium loaded liquid scintillator detectors located near and far from the center of the reactor array. The estimated systematic uncertainty associated with the measurement is less than 0.6%. Based on three years of data, the expected statistical error is about 0.3% and it would be sensitive to measure the neutrino mixing angle in the range, sin{sup 2}(2{theta}{sub 13})> 0.02. In this talk, the overview and status of RENO experiment are described.

46 INSTRUMENTATION RELATED TO NUCLEAR SCIENCE AND ↗

Reconstruction of GeV Neutrino Events in LENA

LENA (Low Energy Neutrino Astronomy) is a proposed next generation liquid-scintillator detector with about 50 kt target mass. Besides the detection of solar neutrinos, geoneutrinos, supernova neutrinos and the search for the proton decay, LENA could also be used as the far detector of a next generation neutrino beam. The present contribution outlines the status of the Monte Carlo studies towards the reconstruction of GeV neutrinos in LENA. Both the tracking capabilities at a few hundred MeV, most interesting for a beta beam, and above 1 GeV for a superbeam experiment are presented.

72 PHYSICS OF ELEMENTARY PARTICLES AND FIELDS↗

Muon density enhancement with a tapered capillary method

The focusing effect of a muon beam with a tapered capillary method has been investigated in a range from 4.2 MeV to 9.2 MeV (i.e. from 30 MeV/c to 45 MeV/c in momentum). We injected the muon beam into a pair of narrowing (tapered) plates and tubes made of glass, copper and gold-coated copper, and measured the energy distribution of the muon leaving from the outlet. The plates were tilted from an inlet of 40 mm to an outlet of 20 mm. The density enhancement was more prominent with the plates made of heavier elements. The largest beam density enhancement at 10 mm downstream of the outlet was 1.3 with the gold-coated copper narrowing plates. The enhancement was composed of muons scattered with a small angle. Their energy was slightly less than that of the initial beam. This effect did not depend on the surface roughness. The result strongly suggests a simple and effective way to increase the muon beam density for a small target.

46 INSTRUMENTATION RELATED TO NUCLEAR SCIENCE AND ↗

Resonance Structure with Polarization Experiments at MAMI

The Mainz Microtron MAMI is an ideal facility to study the hadron structure with the electromagnetic probe. With the new accelerator stage, the Harmonic Double-Sided Microtron (HDSM), which is in operation since 2007, high-intensity polarized electron and photon beams with energies up to 1.6 GeV are delivered to the experiments. Polarized proton, deuteron, {sup 3}He targets, and recoil proton polarimeters are available to allow a broad range of polarization observables for low-mass nucleon resonances to be measured. In this talk, an overview over selected recent double polarization experiments at MAMI is given.

72 PHYSICS OF ELEMENTARY PARTICLES AND FIELDS↗

Near Detectors for a Neutrino Factory

The baseline design for a Neutrino Factory includes the need for one or more near detectors.The near detectors must be designed to carry out measurements essential to the sensitivity of the oscillation-physics program. In addition, the intense neutrino beam delivered by the Neutrino Factory makes it possible to carry out a unique neutrino-physics program at the near detectors. This program includes fundamental electroweak and QCD physics. The near detector must also be capable of searching for new physics, for example by detecting tau-leptons which are particularly sensitive probes of non-standard interactions at source and at detection. This paper is extracted from the Near Detector chapter of the Neutrino Factory Interim Design Report.

46 INSTRUMENTATION RELATED TO NUCLEAR SCIENCE AND ↗

Measurement of Geo-neutrinos with KamLAND

Radioactive isotopes inside the Earth produce geo-neutrinos through beta decays. Geo-neutrinos could be direct probes to investigate the interior of the Earth as a supplement to the current geophysical survey that mainly relies on an indirect seismic approach. After the Kamioka liquid scintillator antineutrino detector (KamLAND) reported the first indication of geo-neutrinos in 2005, we have accumulated data for a total of 2,135 days of live-time and achieved a lower background level by purifying liquid scintillator. The number of obtained geo-neutrino events is 106{sub -28}{sup +29} corresponding to an electron antineutrino flux of 4.3{sub -1.1}{sup +1.2}x10{sup 6} cm{sup -2} s{sup -1} from {sup 238}U and {sup 232}Th series at the Earth's surface. The null hypothesis for the existence of geo-neutrinos is excluded at the 99.997% confidence level. We combined this precise result with that of the Borexino experiment to obtain 20.0{sub -8.6}{sup +8.8} TW as a contribution of {sup 238}U and {sup 232}Th to the Earth heat flow.

46 INSTRUMENTATION RELATED TO NUCLEAR SCIENCE AND ↗

Modeling of a Low-Background Spectroscopic Position-Sensitive Neutron Detector

A new low-background spectroscopic direction-sensitive neutron detector that would allow one to reduce the neutron background component in passive and active neutron detection techniques is proposed. The detector is based on thermal neutron detectors surrounded by a fast neutron scintillation detector, which serves at the same time as a neutron moderator. Direction sensitivity is achieved by coincidence/anticoincidence analysis between different parts of the scintillator. Results of mathematical modeling of several detector configurations are presented.

46 INSTRUMENTATION RELATED TO NUCLEAR SCIENCE AND ↗

Active Inspection of Nuclear Materials Using {sup 4}He Scintillation Detectors

The detection of fissionable materials by neutron and high-energy photon active interrogation methods is explored using {sup 4}He scintillation detectors to search for prompt and delayed neutron signature. The low electron density of {sup 4}He in addition to its pulse shape discrimination capability allows strong rejection of gamma radiation. For the detection of the prompt neutron signatures, this capability is important as the signal produced by induced fission is accompanied by intense gamma radiation. The nanosecond time resolution of {sup 4}He scintillation detectors can be used for time-of-flight measurements aimed at determining the energy of the emitted neutrons. For delayed neutron detection, the insensitivity to the low energy neutrons present from non-signal reactions is inherent. Unlike detectors requiring a moderator, this technology can easily be collimated to reduce sensitivity to neutrons from outside the field of interest. The performance of the detectors for these applications is studied using GEANT4 computer modeling, based on measured detector parameters. A comparison is made with technologies typically used for these applications, i.e. heavily shielded organic scintillators for prompt neutron detection and Cd-lined {sup 3}He neutron detectors for the detection of delayed neutrons.

46 INSTRUMENTATION RELATED TO NUCLEAR SCIENCE AND ↗