Engineering Papers⌕ Search

SEARCH · Engineering Papers

Results for “SAMPLING DEVICE”

Search indexed NASA NTRS and DOE OSTI research on propulsion, heat transfer, battery materials and energy systems. Follow report and document links to the original sources.

Quote a phrase for an exact phrase match. Source license links do not imply unrestricted reuse.

At least 433 records · Page 24

In Situ Chemical Monitoring and Imaging of Contents within Microfluidic Devices Having a Porous Membrane Wall Using Liquid Microjunction Surface Sampling Probe Mass Spectrometry

The ability to observe dynamic chemical processes (e.g., signaling, transport, etc.) in vivo or in situ using nondestructive chemical imaging opens a new door to understanding the complex dynamics of developing biological systems. With the advent of “biology-on-a-chip” devices has come the ability to monitor dynamic chemical processes in a controlled environment, using these engineered habitats to capture key features of natural systems while allowing visual observation of system development. Having the capability to spatially and temporally map the chemical signals within these devices may yield new insights into the forces that drive biosystem development. Here, a porous membrane sealed microfluidic device was designed to allow normal microfluidic operation while enabling continuous, location specific sampling and chemical characterization by liquid microjunction surface sampling probe mass spectrometry (LMJ-SSP MS). LMJ-SSP was used to extract fluids with nL-to-μL/min flow rates directly from selected areas of the microfluidic device without negatively impacting the device function. These extracts were subsequently characterized using MS. This technique was used to acquire MS images of the entirety of several multi-input microfluidic devices having different degrees of fluid mixing. LMJ-SSP MS imaging visualized the spatial distribution of chemical components within the microfluidic channels and could visualize chemical reactions occurring in the device. These microfluidic devices with a porous membrane wall are wholly compatible with the construction of biology-on-a-chip devices. This ultimately would enable correlation of biosystem physical structure with an evolving chemical environment

47 OTHER INSTRUMENTATION↗

Energy Delivery Systems with Verifiable Trustworthiness (Final Report)

Energy Delivery Systems (EDS) must be verified to be free from intrusive and malicious software. One way of verifying this software is to perform device scans to detect malicious code. Because it is possible to have “fileless” malware that exists only in device (volatile) memory, offline scanning and even many forms of online scanning is insufficient for detection. This project (“Verify”) addresses this need by performing direct sampling of memory during device operation to detect unexpected or modified software while not interfering with device operation. The Verify project provides a proof-of-concept of detection by random sampling combined with remote software- and timing-based attestation methods for robust detection of in-memory threats. An external review of Verify was performed by our partner, General Electric (GE), and a summary of their findings is provided.

97 MATHEMATICS AND COMPUTING↗

Task-Specific Ionic Compounds for In-Field Sample Preparation Poster

In the event of a nuclear detonation, actinide and fission product-containing debris can be analyzed to provide information about the nature of the device. In-field sample dissolution prior to transport to a laboratory is critical for reducing the time between an event and delivery of information to decision makers. However, the best dissolution methods utilize liquid strong acid solutions, which are incompatible with field collection Standard Operating Procedure. What is required are solid materials that, when mixed with water in the field, can provide the strong digestion and dissolution properties of nitric and hydrofluoric acids. Fluorohydrogenate ionic liquids have shown a remarkable ability to dissolve a wide range of materials, from refractory actinide oxides to cementitious material such as calcium silicates. These strong dissolution properties are due to the neutral hydrofluoric acid that is bound to the anion component of the ionic liquid. Because these materials are liquids, they are also incompatible with Standard Operating Procedure. However, the physiochemical properties of ionic liquids, such as the melting point, can be readily tuned through minor modification of the molecular structure of the cations and anions. Thus, we hypothesize that by synthesizing modified cations, novel ionic compounds with melting points above ambient but with the same anion and bound hydrofluoric acid – and thus similar digestion and dissolution properties – as current fluorohydrogenate ionic liquids can be produced. These solid materials would be compatible with current Standard Operating Procedure, and would allow for rapid, in-field dissolution of samples, shortening the time to actionable information after an event.

37 INORGANIC, ORGANIC, PHYSICAL, AND ANALYTICAL CH↗

Comprehensive Single-Shot Proteomics with FAIMS on a Hybrid Orbitrap Mass Spectrometer

Liquid chromatography (LC) prefractionation is often implemented to increase proteomic coverage; however, while effective, this approach is laborious, requires considerable sample amount, and can be cumbersome. We describe how interfacing a recently described high-field asymmetric waveform ion mobility spectrometry (FAIMS) device between a nanoelectrospray ionization (nanoESI) emitter and an Orbitrap hybrid mass spectrometer (MS) enables the collection of single-shot proteomic data with comparable depth to that of conventional two-dimensional LC approaches. This next generation FAIMS device incorporates improved ion sampling at the ESI–FAIMS interface, increased electric field strength, and a helium-free ion transport gas. With fast internal compensation voltage (CV) stepping (25 ms/transition), multiple unique gas-phase fractions may be analyzed simultaneously over the course of an MS analysis. We have comprehensively demonstrated how this device performs for bottom-up proteomics experiments as well as characterized the effects of peptide charge state, mass loading, analysis time, and additional variables. We also offer recommendations for the number of CVs and which CVs to use for different lengths of experiments. Internal CV stepping experiments increase protein identifications from a single-shot experiment to >8000, from over 100 000 peptide identifications in as little as 5 h. In single-shot 4 h label-free quantitation (LFQ) experiments of a human cell line, we quantified 7818 proteins with FAIMS using intra-analysis CV switching compared to 6809 without FAIMS. Single-shot FAIMS results also compare favorably with LC fractionation experiments. Furthermore, a 6 h single-shot FAIMS experiment generates 8007 protein identifications, while four fractions analyzed for 1.5 h each produce 7776 protein identifications.

37 INORGANIC, ORGANIC, PHYSICAL, AND ANALYTICAL CH↗

SERPENT 2 and TRIPOLI-4 neutronics benchmarking of the Jules Horowitz reactor

Jules Horowitz Reactor (JHR) is a future center for nuclear material testing in Europe, currently under construction at CEA Cadarache in southern France. It has been modelled extensively with CEA's HORUS3D/N neutron calculation package, that includes a Monte-Carlo neutron transport code TRIPOLI-4. In order to support the future computational analyses on the reactor core physics, VTT's Monte Carlo neutronics code SERPENT 2 has been used to create an alternative model of the JHR, taking advantage of the pre-existing Constructive Solid Geometry (CSG) structures on which the TRIPOLI-4 model was built. This work describes a benchmark, in which two JHR core configurations were analyzed using both of these models. The first configuration is a fresh fuel core at the beginning of life, in which aluminum based dummy-devices are installed in the reactor test positions. The second configuration represents the end-of-cycle equilibrium core with a heterogeneous burnup distribution, in which CALIPSO devices containing cladding material samples are installed at the in-core experimental positions, while the reflector positions are occupied by DEN-REP devices containing UO{sub 2} fuel. Neutron flux spectra and heat deposition are the parameters of interest in this study, due to their high importance in creating the desired experimental irradiation environment. The impact of delayed gamma energy deposition will be studied in detail, since the two models account for it with different methods. This work aims to establish a SERPENT 2 model of JHR, understanding its differences and agreements with TRIPOLI-4, and discussing its potential future applications. (authors)

21 SPECIFIC NUCLEAR REACTORS AND ASSOCIATED PLANTS↗

Co-flow injection for serial crystallography at X-ray free-electron lasers

Serial femtosecond crystallography (SFX) is a powerful technique that exploits X-ray free-electron lasers to determine the structure of macromolecules at room temperature. Despite the impressive exposition of structural details with this novel crystallographic approach, the methods currently available to introduce crystals into the path of the X-ray beam sometimes exhibit serious drawbacks. Samples requiring liquid injection of crystal slurries consume large quantities of crystals (at times up to a gram of protein per data set), may not be compatible with vacuum configurations on beamlines or provide a high background due to additional sheathing liquids present during the injection. Proposed and characterized here is the use of an immiscible inert oil phase to supplement the flow of sample in a hybrid microfluidic 3D-printed co-flow device. Co-flow generation is reported with sample and oil phases flowing in parallel, resulting in stable injection conditions for two different resin materials experimentally. A numerical model is presented that adequately predicts these flow-rate conditions. The co-flow generating devices reduce crystal clogging effects, have the potential to conserve protein crystal samples up to 95% and will allow degradation-free light-induced time-resolved SFX.

3D printing↗

Detection of Delayed Neutrons from Fissionable Samples: Monte Carlo Modelling and Physical Assumptions for a Design of the DET-12 Device

An activation of fissionable materials with neutrons has been considered as a possible neutron diagnostic of D–D and D–T fusion plasma. Fission reaction caused by fusion neutrons leads up to emission of secondary neutrons: prompt and delayed. Physical assumptions have been outlined to design a new device (DET-12) for measurements of delayed neutrons emitted from samples of fissionable materials activated with neutrons at big fusion-plasma devices. The aim is to support a classic neutron activation method used as one of plasma diagnostics at tokamaks or stellarators. An interpretation of the time decay of delayed neutrons enables an assessment of the primary neutron flux which induced fission reaction. Monte Carlo calculations have been carried out in order to elaborate the method considered. Nuclides like: pure {sup 235}U, {sup 238}U and {sup 232}Th, have been selected as possible materials to be irradiated. Physical fundamentals of generation of the delayed neutrons are mentioned and a resulting concept of the DET-12 device, built in the Institute of Nuclear Physics, Poland, is presented. A general size and dimensions of particular constituent material layers, and a number and placement of neutron detectors are optimized by means of Monte Carlo modelling. Recommendations for a technical design of the measuring chamber were formulated. Detection efficiency of DET-12 has been also estimated.

70 PLASMA PHYSICS AND FUSION TECHNOLOGY↗

MultiPEM Toolbox: User Manual [Rev. 2]

This document explains use of the Multi-Phenomenology Explosion Monitoring (Multi PEM) Toolbox, a collection of R scripts for estimating the unknown device parameters of a new event with uncertainty quantification. The methodology and application used for illustration in this user manual are fully documented in a Los Alamos National Laboratory technical report hereafter designated “WPA” for reference. Additional details on the application are found in a recent journal article. Two assessment types are available: rapid and complete. Rapid assessments are conducted in two stages, as described in Section 2. In the first stage, calibration data are used to estimate forward and error model parameters (WPA, §5.1) and (if relevant) errors-in-variables yield values for calibration sources (WPA, §3, Equation (3)). In the second stage, new event data are used to estimate the unknown new event device parameters (WPA, §5.2) with uncertainty quantification. Two options for treating the inferred first stage parameters in second stage Bayesian analysis are available: fixing them at their maximum likelihood estimate (default), or multiple imputation. Multiple imputation involves utilizing several posterior samples (imputations) of the first stage parameters as fixed values in the second stage posterior sampling of the new event device parameters. Second stage sampling is conducted across imputations in parallel to improve computational efficiency. This method produces improved uncertainty quantification of the new event device parameters compared with the default treatment of the first stage parameters, at the expense of additional computation. Complete assessments are conducted in a single stage, as described in Section 3. Calibration and (if relevant) new event data are used simultaneously to estimate all forward model, error model, and (if relevant) new event device parameters with uncertainty quantification on the latter. As the name suggests, rapid assessments generally run substantially faster than complete assessments (even with multiple imputation), because the results of first stage analysis can be stored and incorporated into estimating a relatively low-dimensional space of new event device parameters whenever relevant new event data becomes available. On the other hand, complete assessments must be run on the full set of model and device parameters with calibration and new event data every time the latter becomes available.

97 MATHEMATICS AND COMPUTING↗

Composition and method for capture and degradation of PFAS

Materials for binding per- and polyfluoroalkyl substances (PFAS) are disclosed. A fluidic device comprising the materials for detection and quantification of PFAS in a sample is disclosed. The fluidic device may be configured for multiplexed analyses. Also disclosed are methods for sorbing and remediating PFAS in a sample. The sample may be groundwater containing, or suspected of containing, one or more PFAS.

Motkuri, Radha K.↗

Fluidic impedance platform for in-situ detection and quantification of PFAS in groundwater

Materials for binding per- and polyfluoroalkyl substances (PFAS) are disclosed. A fluidic device comprising the materials for detection and quantification of PFAS in a sample is disclosed. The fluidic device may be configured for multiplexed analyses. Also disclosed are methods for sorbing and remediating PFAS in a sample. The sample may be groundwater containing, or suspected of containing, one or more PFAS.

Chatterjee, Sayandev↗

Remote vacuum or pressure sealing device and method for critical isolated systems

A remote vacuum or pressure sealing apparatus and method for making a radiation tolerant, remotely prepared seal that maintains a vacuum or pressure tight seal throughout a wide temperature range. The remote sealing apparatus includes a fixed threaded sealing surface on an isolated system, a gasket, and an insert consisting of a plug with a protruding sample holder. An insert coupling device, provided for inserting samples within the isolated system, includes a threaded fastener for cooperating with the fixed threaded sealing surface on the isolated system. The insert coupling device includes a locating pin for azimuthal orientation, coupling pins, a tooted coaxial socket wrench, and an insert coupling actuator for actuating the coupling pins. The remote aspect of the sealing apparatus maintains the isolation of the system from the user's environment, safely preserving the user and the system from detrimental effect from each respectively.

47 OTHER INSTRUMENTATION↗

Cloud condensation nucleus counter by impactor sampling technique

Unlike typical CCN counters, this device counts the numbers of water droplets condensed on aerosol particles sampled on a microcover glass at various different relative humidities. The relative humidities ranged from 75 percent to a calculated value of 110 percent. A schematic of the apparatus is shown. The individual CCN can be identified in an optical micrograph and scanning electron micrograph and may be inspected for their chemical composition later.

Ohtake, T.↗

Rapid thermal processing by stamping

A rapid thermal processing device and methods are provided for thermal processing of samples such as semiconductor wafers. The device has components including a stamp (35) having a stamping surface and a heater or cooler (40) to bring it to a selected processing temperature, a sample holder (20) for holding a sample (10) in position for intimate contact with the stamping surface; and positioning components (25) for moving the stamping surface and the stamp (35) in and away from intimate, substantially non-pressured contact. Methods for using and making such devices are also provided. These devices and methods allow inexpensive, efficient, easily controllable thermal processing.

42 ENGINEERING↗

A capillary-based microfluidic device enables primary high-throughput room-temperature crystallographic screening

A novel capillary-based microfluidic strategy to accelerate the process of small-molecule-compound screening by room-temperature X-ray crystallography using protein crystals is reported. The ultra-thin microfluidic devices are composed of a UV-curable polymer, patterned by cleanroom photolithography, and have nine capillary channels per chip. The chip was designed for ease of sample manipulation, sample stability and minimal X-ray background. 3D-printed frames and cassettes conforming to SBS standards are used to house the capillary chips, providing additional mechanical stability and compatibility with automated liquid- and sample-handling robotics. These devices enable an innovative in situ crystal-soaking screening workflow, akin to high-throughput compound screening, such that quantitative electron density maps sufficient to determine weak binding events are efficiently obtained. This work paves the way for adopting a room-temperature microfluidics-based sample delivery method at synchrotron sources to facilitate high-throughput protein-crystallography-based screening of compounds at high concentration with the aim of discovering novel binding events in an automated manner.

37 INORGANIC, ORGANIC, PHYSICAL, AND ANALYTICAL CH↗

SpinDX Case Study

SpinDX, often referred to as a "lab-on-a-disk" is a portable, medical diagnostic platform that uses a disposable, centrifugal disk with microfluidic flow paths to manipulate a biological sample. This allows multiple tests to be carried out on a single sample with no preparation required. The device operates by distributing drops of raw, unprocessed samples into different channels that function as dozens of tiny test tubes. When the disc spins, the samples interact with test reagents inside the channels. If there is a chemical interaction between the sample and the reagent, the tip of the channel will produce a fluorescent glow indicating that there is an infectious agent present. The data is then transferred to a software interface that displays the test results.

47 OTHER INSTRUMENTATION↗

Site-specific plan-view (S)TEM sample preparation from thin films using a dual-beam FIB-SEM

To fully evaluate the atomic structure, and associated properties of materials using transmission electron microscopy, examination of samples from three non-collinear orientations is needed. This is particularly challenging for thin films and nanoscale devices built on substrates due to limitations with plan-view sample preparation. In this work, a new method for preparation of high-quality, site-specific, plan-view TEM samples from thin-films grown on substrates, is presented and discussed. Here, it is based on using a dual-beam focused ion beam scanning electron microscope (FIB-SEM) system. To demonstrate the method, the samples were prepared from thin films of perovskite oxide BaSnO 3 grown on a SrTiO 3 substrate and metal oxide IrO 2 on a TiO 2 substrate, ranging from 20–80 nm in thicknesses using molecular beam epitaxy. While the method is optimized for the thin films, it can be extended to other site-specific plan-view samples and devices build on wafers. Aberration-corrected STEM was used to evaluate the quality of the samples and their applicability for atomic-resolution imaging and analysis.

BaSnO3↗

Microtrap assembly for greenhouse gas and air pollution monitoring

A microtrap assembly includes a carbon nanotube sorbent. The microtrap assembly may be employed as a preconcentrator operable to deliver a sample to an analytical device to measure the concentrations of greenhouse gases. A system includes a microtrap having a carbon nanotube sorbent for measuring the concentrations of greenhouse gases in a sample.

54 ENVIRONMENTAL SCIENCES↗

Absence of evidence for chiral Majorana modes in quantum anomalous Hall-superconductor devices

A quantum anomalous Hall (QAH) insulator coupled to an s-wave superconductor is predicted to harbor chiral Majorana modes. A recent experiment interprets the half-quantized two-terminal conductance plateau as evidence for these modes in a millimeter-size QAH-niobium hybrid device. However, non-Majorana mechanisms can also generate similar signatures, especially in disordered samples. Here, we studied similar hybrid devices with a well-controlled and transparent interface between the superconductor and the QAH insulator. When the devices are in the QAH state with well-aligned magnetization, the two-terminal conductance is always half-quantized. Our experiment provides a comprehensive understanding of the superconducting proximity effect observed in QAH-superconductor hybrid devices and shows that the half-quantized conductance plateau is unlikely to be induced by chiral Majorana fermions in samples with a highly transparent interface.

Science & Technology - Other Topics↗