Engineering Papers⌕ Search

SEARCH · Engineering Papers

Results for “S Parameters”

Search indexed NASA NTRS and DOE OSTI research on propulsion, heat transfer, battery materials and energy systems. Follow report and document links to the original sources.

Quote a phrase for an exact phrase match. Source license links do not imply unrestricted reuse.

At least 433 records · Page 24

Impact of baryonic processes on weak-lensing cosmology: Power spectrum, nonlocal statistics, and parameter bias

We study the impact of baryonic physics on cosmological parameter estimation with weak-lensing surveys. We run a set of cosmological hydrodynamics simulations with different galaxy formation models. We then perform ray-tracing simulations through the total matter density field to generate 100 independent convergence maps with a field of view of 25 deg{sup 2}, and we use them to examine the ability of the following three lensing statistics as cosmological probes: power spectrum (PS), peak counts, and Minkowski functionals (MFs). For the upcoming wide-field observations, such as the Subaru Hyper Suprime-Cam (HSC) survey with a sky coverage of 1400 deg{sup 2}, these three statistics provide tight constraints on the matter density, density fluctuation amplitude, and dark energy equation of state, but parameter bias is induced by baryonic processes such as gas cooling and stellar feedback. When we use PS, peak counts, and MFs, the magnitude of relative bias in the dark energy equation of state parameter w is at a level of, respectively, δw∼0.017, 0.061, and 0.0011. For the HSC survey, these values are smaller than the statistical errors estimated from Fisher analysis. The bias could be significant when the statistical errors become small in future observations with a much larger survey area. We find that the bias is induced in different directions in the parameter space depending on the statistics employed. While the two-point statistic, i.e., PS, yields robust results against baryonic effects, the overall constraining power is weak compared with peak counts and MFs. On the other hand, using one of peak counts or MFs, or combined analysis with multiple statistics, results in a biased parameter estimate. The bias can be as large as 1σ for the HSC survey and will be more significant for upcoming wider-area surveys. We suggest to use an optimized combination so that the baryonic effects on parameter estimation are mitigated. Such a “calibrated” combination can place stringent and robust constraints on cosmological parameters.

79 ASTRONOMY AND ASTROPHYSICS↗

Statistical coverage for supersymmetric parameter estimation: a case study with direct detection of dark matter

Models of weak-scale supersymmetry offer viable dark matter (DM) candidates. Their parameter spaces are however rather large and complex, such that pinning down the actual parameter values from experimental data can depend strongly on the employed statistical framework and scanning algorithm. In frequentist parameter estimation, a central requirement for properly constructed confidence intervals is that they cover true parameter values, preferably at exactly the stated confidence level when experiments are repeated infinitely many times. Since most widely-used scanning techniques are optimised for Bayesian statistics, one needs to assess their abilities in providing correct confidence intervals in terms of the statistical coverage. Here we investigate this for the Constrained Minimal Supersymmetric Standard Model (CMSSM) when only constrained by data from direct searches for dark matter. We construct confidence intervals from one-dimensional profile likelihoods and study the coverage by generating several pseudo-experiments for a few benchmark sets of pseudo-true parameters. We use nested sampling to scan the parameter space and evaluate the coverage for the benchmarks when either flat or logarithmic priors are imposed on gaugino and scalar mass parameters. The sampling algorithm has been used in the configuration usually adopted for exploration of the Bayesian posterior. We observe both under- and over-coverage, which in some cases vary quite dramatically when benchmarks or priors are modified. We show how most of the variation can be explained as the impact of explicit priors as well as sampling effects, where the latter are indirectly imposed by physicality conditions. For comparison, we also evaluate the coverage for Bayesian credible intervals, and observe significant under-coverage in those cases.

79 ASTRONOMY AND ASTROPHYSICS↗

New constraints on cosmological parameters and neutrino properties using the expansion rate of the Universe to z ∼ 1.75

We have assembled a compilation of observational Hubble parameter measurements estimated with the differential evolution of cosmic chronometers, in the redshift range 0 < z < 1.75. This sample has been used, in combination with CMB data and with the most recent estimate of the Hubble constant H{sub 0}, to derive new constraints on several cosmological parameters. The new Hubble parameter data are very useful to break some of the parameter degeneracies present in CMB-only analysis, and to constrain possible deviations from the standard (minimal) flat ΛCDM model. The H(z) data are especially valuable in constraining Ω{sub k} and Ω{sub DE} in models that allow a variation of those parameters, yielding constraints that are competitive with those obtained using Supernovae and/or baryon acoustic oscillations. We also find that our H(z) data are important to constrain parameters that do no affect directly the expansion history, by breaking or reducing degeneracies with other parameters. We find that N{sub rel} = 3.45±0.33 using WMAP 7-years data in combination with South Pole Telescope data and our H(z) determinations (N{sub rel} = 3.71±0.45 using Atacama Cosmology Telescope data instead of South Pole Telescope). We exclude N{sub rel} > 4 at 95% CL (74% CL) using the same datasets combinations. We also put competitive limits on the sum of neutrino masses, Σm{sub ν} < 0.24 eV at 68% confidence level. These results have been proven to be extremely robust to many possible systematic effects, such as the initial choice of stellar population synthesis model adopted to estimate H(z) and the progenitor-bias.

79 ASTRONOMY AND ASTROPHYSICS↗

Algorithm sensitivity analysis and parameter tuning for tissue image segmentation pipelines

Motivation: Sensitivity analysis and parameter tuning are important processes in large-scale image analysis. They are very costly because the image analysis workflows are required to be executed several times to systematically correlate output variations with parameter changes or to tune parameters. An integrated solution with minimum user interaction that uses effective methodologies and high performance computing is required to scale these studies to large imaging datasets and expensive analysis workflows. Results: The experiments with two segmentation workflows show that the proposed approach can (i) quickly identify and prune parameters that are non-influential; (ii) search a small fraction (about 100 points) of the parameter search space with billions to trillions of points and improve the quality of segmentation results (Dice and Jaccard metrics) by as much as 1.42 x compared to the results from the default parameters; (iii) attain good scalability on a high performance cluster with several effective optimizations. Conclusions: Our work demonstrates the feasibility of performing sensitivity analyses, parameter studies and auto-tuning with large datasets. The proposed framework can enable the quantification of error estimations and output variations in image segmentation pipelines.

Biochemistry & Molecular Biology↗

SDSS-IV MaStar: theoretical atmospheric parameters for the MaNGA stellar library

ABSTRACT We calculate the fundamental stellar parameters effective temperature, surface gravity, and iron abundance – Teff, log g, [Fe/H] – for the final release of the Mapping Nearby Galaxies at APO (MaNGA) Stellar Library (MaStar), containing 59 266 per-visit-spectra for 24 290 unique stars at intermediate resolution (R ∼ 1800) and high S/N (median = 96). We fit theoretical spectra from model atmospheres by both MARCS and BOSZ-ATLAS9 to the observed MaStar spectra, using the full spectral fitting code pPXF. We further employ a Bayesian approach, using a Markov Chain Monte Carlo (MCMC) technique to map the parameter space and obtain uncertainties. Originally in this paper, we cross match MaStar observations with Gaia photometry, which enable us to set reliable priors and identify outliers according to stellar evolution. In parallel to the parameter determination, we calculate corresponding stellar population models to test the reliability of the parameters for each stellar evolutionary phase. We further assess our procedure by determining parameters for standard stars such as the Sun and Vega and by comparing our parameters with those determined in the literature from high-resolution spectroscopy (APOGEE and SEGUE) and from lower resolution matching template (LAMOST). The comparisons, considering the different methodologies and S/N of the literature surveys, are favourable in all cases. Our final parameter catalogue for MaStar cover the following ranges: 2592 ≤ Teff ≤ 32 983 K; −0.7 ≤ log g ≤ 5.4 dex; −2.9 ≤ [Fe/H] ≤ 1.0 dex and will be available with the last SDSS-IV Data Release, in 2021 December.

79 ASTRONOMY AND ASTROPHYSICS↗

Parameter inference with non-linear galaxy clustering: accounting for theoretical uncertainties

ABSTRACT We implement euclidemulator (version 1), an emulator for the non-linear correction of the matter power spectrum, into the Markov chain Monte Carlo forecasting code montepython. We compare the performance of halofit, hmcode, and euclidemulator1, both at the level of power spectrum prediction and at the level of posterior probability distributions of the cosmological parameters, for different cosmological models and different galaxy power spectrum wavenumber cut-offs. We confirm that the choice of the power spectrum predictor has a non-negligible effect on the computed sensitivities when doing cosmological parameter forecasting, even for a conservative wavenumber cut-off of $0.2\, h\, {\rm Mpc}^{-1}$. We find that euclidemulator1 is on average up to 17 per cent more sensitive to the cosmological parameters than the other two codes, with the most significant improvements being for the Hubble parameter of up to 42 per cent and the equation of state of dark energy of up to 26 per cent, depending on the case. In addition, we point out that the choice of the power spectrum predictor contributes to the risk of computing a significantly biased mean cosmology when doing parameter estimations. For the four tested scenarios we find biases, averaged over the cosmological parameters, of between 0.5σ and 2σ (from below 1σ up to 6σ for individual parameters). This paper provides a proof of concept that this risk can be mitigated by taking a well-tailored theoretical uncertainty into account as this allows to reduce the bias by a factor of 2 to 5, depending on the case under consideration, while keeping posterior credibility contours small: the standard deviations are amplified by a factor of ≤1.4 in all cases.

Astronomy & Astrophysics↗

Parameter uncertainty analysis of a biokinetic model of caesium

Parameter uncertainties for the biokinetic model of caesium (Cs) developed by Leggett et al. were inventoried and evaluated. The methods of parameter uncertainty analysis were used to assess the uncertainties of model predictions with the assumptions of model parameter uncertainties and distributions. Furthermore, the importance of individual model parameters was assessed by means of sensitivity analysis. The calculated uncertainties of model predictions were compared with human data of Cs measured in blood and in the whole body. It was found that propagating the derived uncertainties in model parameter values reproduced the range of bioassay data observed in human subjects at different times after intake. The maximum ranges, expressed as uncertainty factors (UFs) (defined as a square root of ratio between 97.5th and 2.5th percentiles) of blood clearance, whole-body retention and urinary excretion of Cs predicted at earlier time after intake were, respectively: 1.5, 1.0 and 2.5 at the first day; 1.8, 1.1 and 2.4 at Day 10 and 1.8, 2.0 and 1.8 at Day 100; for the late times (1000 d) after intake, the UFs were increased to 43, 24 and 31, respectively. The model parameters of transfer rates between kidneys and blood, muscle and blood and the rate of transfer from kidneys to urinary bladder content are most influential to the blood clearance and to the whole-body retention of Cs. For the urinary excretion, the parameters of transfer rates from urinary bladder content to urine and from kidneys to urinary bladder content impact mostly. The implication and effect on the estimated equivalent and effective doses of the larger uncertainty of 43 in whole-body retention in the later time, say, after Day 500 will be explored in a successive work in the framework of EURADOS.

61 RADIATION PROTECTION AND DOSIMETRY↗

Evaluating the Limits of QAOA Parameter Transfer at High-Rounds on Sparse Ising Models With Geometrically Local Cubic Terms

The emergent practical applicability of the Quantum Approximate Optimization Algorithm (QAOA) for approximate combinatorial optimization is a subject of considerable interest. One of the primary limitations of QAOA is the task of finding a set of good parameters, which is usually done using a variational optimization loop. Parameter transfer, or parameter concentration, is a phenomenon where QAOA angles trained on problem instances that are self-similar tend to perform well for other problem instances from that similar class. This suggests a potentially highly efficient and scalable non-variational learning method for QAOA angle finding. In this work, we systematically study QAOA parameter transferability from small problem sizes (16 and 27 decision variables) onto large problem instances (up to 156 qubits) for heavy-hex graph Ising models with geometrically local higher order terms using the Julia based QAOA simulation tool \texttt{JuliQAOA} to perform classical angle finding for up to $49$ QAOA layers ($p$). Parameter transfer of the fixed angles is validated using a combination of full statevector, Projected Entangled Pair States (PEPS), Matrix Product State (MPS), and LOWESA numerical simulations. We find that the QAOA parameter transfer from single instances applied to other (unseen) problem instances does not in general provide monotonically improving performance as a function of $p$ - there are many cases where the performance temporarily decreases as a function of $p$ - but despite this the transferred angles have a general trend of improved expectation value as the QAOA depth increases, in many cases converging close to the true ground-state energy of the $100+$ qubit instances. We also sample the hardware-compatible Ising models using the ensemble of transfer-learned QAOA parameters on several superconducting qubit IBM Quantum processors with 127, 133, and 156 qubits. We find continuous solution quality improvement of the hardware-compatible QAOA circuits run on the IBM NISQ processors up to $p=5$ on \texttt{ibm\_fez}, up to $p=9$ on \texttt{ibm\_torino}, and up to $p=10$ on \texttt{ibm\_pittsburgh}.

71 CLASSICAL AND QUANTUM MECHANICS, GENERAL PHYSIC↗

Two-particle Bose-Einstein correlations and their Lévy parameters in PbPb collisions at s N N = 5.02 TeV

Two-particle Bose–Einstein momentum correlation functions are studied for charged-hadron pairs in lead-lead collisions at a center-of-mass energy per nucleon pair of s NN = 5.02 TeV . The data sample, containing 4.27 × 10 9 minimum bias events corresponding to an integrated luminosity of 0.607 nb − 1 , was collected by the CMS experiment in 2018. The experimental results are discussed in terms of a Lévy-type source distribution. The parameters of this distribution are extracted as functions of particle pair average transverse mass and collision centrality. These parameters include the Lévy index or shape parameter α , the Lévy scale parameter R , and the correlation strength parameter λ . The source shape, characterized by α , is found to be neither Cauchy nor Gaussian, implying the need for a full Lévy analysis. Similarly to what was previously found for systems characterized by Gaussian source radii, a hydrodynamical scaling is observed for the Lévy R parameter. The λ parameter is studied in terms of the core-halo model. ©2024 CERN, for the CMS Collaboration 2024 CERN

72 PHYSICS OF ELEMENTARY PARTICLES AND FIELDS↗

Online Support Vector Regression with Varying Parameters for Time-Dependent Data

Support vector regression (SVR) is a machine learning technique that continues to receive interest in several domains including manufacturing, engineering, and medicine. In order to extend its application to problems in which datasets arrive constantly and in which batch processing of the datasets is infeasible or expensive, an accurate online support vector regression (AOSVR) technique was proposed. The AOSVR technique efficiently updates a trained SVR function whenever a sample is added to or removed from the training set without retraining the entire training data. However, the AOSVR technique assumes that the new samples and the training samples are of the same characteristics; hence, the same value of SVR parameters is used for training and prediction. This assumption is not applicable to data samples that are inherently noisy and non-stationary such as sensor data. As a result, we propose Accurate On-line Support Vector Regression with Varying Parameters (AOSVR-VP) that uses varying SVR parameters rather than fixed SVR parameters, and hence accounts for the variability that may exist in the samples. To accomplish this objective, we also propose a generalized weight function to automatically update the weights of SVR parameters in on-line monitoring applications. The proposed function allows for lower and upper bounds for SVR parameters. We tested our proposed approach and compared results with the conventional AOSVR approach using two benchmark time series data and sensor data from nuclear power plant. The results show that using varying SVR parameters is more applicable to time dependent data.

21 SPECIFIC NUCLEAR REACTORS AND ASSOCIATED PLANTS↗

A consistent approach for the development of a comprehensive data base of time-dependent parameters for concrete engineered barriers

This paper presents a consistent approach for the development of a comprehensive data base of time-dependent hydraulic and transport parameters for concrete engineered barriers of the future Dessel near surface repository for low level waste. The parameter derivation is based on integration of selected data obtained through an extensive literature review, data from experimental studies on cementitious materials specific for the Dessel repository and numerical modelling using physically-based models of water and mass transport. Best estimate parameter values for assessment calculations are derived, together with source and expert range and their probability density function wherever the data was sufficient. We further discuss a numerical method for up-scaling laboratory derived parameter values to the repository scale; the resulting large-scale effective parameters are commensurate with numerical grids used in models for radionuclide migration. To accommodate different levels of conservatism in the various assessment calculations defined by ONDRAF/NIRAS, several sets of parameter values have been derived based on assumptions that introduce different degrees of conservatism. For pertinent parameters, the time evolution of such properties due to the long-term concrete degradation is also addressed. The implementation of the consistent approach is demonstrated by considering the pore water diffusion coefficient as an example. (authors)

12 MANAGEMENT OF RADIOACTIVE AND NON-RADIOACTIVE W↗

The diagnostic capability of x-ray scattering parameters for the characterization of breast cancer

Purpose: The evaluation of the diagnostic capability of easy to measure x-ray scattering profile characterization parameters for the detection of breast cancer in excised samples. The selected parameters are the full width at half maximum (FWHM) and area under the x-ray scattering profile of breast tissue in addition to the ratio of scattering intensities (I{sub 2}/I{sub 1}%) at 1.6 nm{sup -1} to that at 1.1 nm{sup -1} (corresponding to scattering from soft and adipose tissues, respectively). Methods: A histopathologist is asked to classify 36 excised breast tissue samples into healthy or malignant. A conventional x-ray diffractometer is used to acquire the scattering profiles of the investigated samples. The values of three profile characterization parameters are calculated and the diagnostic capability of each is evaluated by determining the optimal cutoffs of scatter diagrams, calculating the diagnostic indices, and plotting the receiver operating characteristic (ROC) curves. Results: At the calculated optimal cutoff for each of the examined parameters, the sensitivity ranged from 78% (for area under curve) up to 94% (for FWHM), the specificity ranged from 94%[for I{sub 2}/I{sub 1}% and area under curve] up to 100% (for FWHM), and the diagnostic accuracy ranged from 86% (for area under curve) up to 97% (for FWHM). The area under the ROC curves is greater than 0.95 for all of the investigated parameters, reflecting a highly accurate diagnostic performance. Conclusions: The discussed tests offered a means to quantitatively evaluate the performance of the suggested breast tissue x-ray scattering characterization parameters. The performance results are promising, indicating that the evaluated parameters would be considered a tool for fast, on spot probing of breast cancer in excised tissue samples.

60 APPLIED LIFE SCIENCES↗

Toward a better understanding of the gamma index: Investigation of parameters with a surface-based distance method

Purpose: The purpose of this work was to clarify the interactions between the parameters used in the {gamma} index with the surface-based distance method, which itself can be viewed as a generalized version of the {gamma} index. The examined parameters included the distance to agreement (DTA)/dose difference (DD) criteria, the percentage used as a passing criterion, and the passing percentage for given DTA/DD criteria. The specific aims of our work were (1) to understand the relationships between the parameters used in the {gamma} index, (2) to determine the detection limit, or the minimum detectable error, of the {gamma} index with a given set of parameters, and (3) to establish a procedure to determine parameters that are consistent with the capacity of an IMRT QA system. Methods: The surface-based distance technique with dose gradient factor was derived, and then the relationship between surface-based distance and {gamma} index was established. The dose gradient factor for plans and measurements of 10 IMRT patients, 10 spine stereotactic radiosurgery (SRS) patients, and 3 Radiological Physics Center (RPC) head and neck phantom were calculated and evaluated. The detection limits of the surface-based distance and {gamma} index methods were examined by introducing known shifts to the 10 IMRT plans. Results: The means of the dose gradient factors were 0.434 mm/% and 0.956 mm/% for the SRS and IMRT plans, respectively. Key quantities (including the mean and 90th and 99th percentiles of the distance distribution) of the surface-based distance distribution between two dose distributions were linearly proportional to the actual shifts. However, the passing percentage of the {gamma} index for a given set of DTA/DD criteria was not associated with the actual shift. For IMRT, using the standard quality assurance criteria of 3 mm/3% DTA/DD and a 90% passing rate, we found that the detection limit of the {gamma} index in terms of global shift was 4.07 mm/4.07 % without noise. Conclusions: Surface-based distance is a direct measure of the difference between two dose distributions and can be used to evaluate or determine parameters for use in calculating the {gamma} index. The dose gradient factor represents the weighting between spatial and dose shift and should be determined before DTA/DD criteria are set. The authors also present a procedure to determine {gamma} index parameters from measurements.

61 RADIATION PROTECTION AND DOSIMETRY↗

A multicriteria framework with voxel-dependent parameters for radiotherapy treatment plan optimization

Purpose: To establish a new mathematical framework for radiotherapy treatment optimization with voxel-dependent optimization parameters. Methods: In the treatment plan optimization problem for radiotherapy, a clinically acceptable plan is usually generated by an optimization process with weighting factors or reference doses adjusted for a set of the objective functions associated to the organs. Recent discoveries indicate that adjusting parameters associated with each voxel may lead to better plan quality. However, it is still unclear regarding the mathematical reasons behind it. Furthermore, questions about the objective function selection and parameter adjustment to assure Pareto optimality as well as the relationship between the optimal solutions obtained from the organ-based and voxel-based models remain unanswered. To answer these questions, the authors establish in this work a new mathematical framework equipped with two theorems. Results: The new framework clarifies the different consequences of adjusting organ-dependent and voxel-dependent parameters for the treatment plan optimization of radiation therapy, as well as the impact of using different objective functions on plan qualities and Pareto surfaces. The main discoveries are threefold: (1) While in the organ-based model the selection of the objective function has an impact on the quality of the optimized plans, this is no longer an issue for the voxel-based model since the Pareto surface is independent of the objective function selection and the entire Pareto surface could be generated as long as the objective function satisfies certain mathematical conditions; (2) All Pareto solutions generated by the organ-based model with different objective functions are parts of a unique Pareto surface generated by the voxel-based model with any appropriate objective function; (3) A much larger Pareto surface is explored by adjusting voxel-dependent parameters than by adjusting organ-dependent parameters, possibly allowing for the generation of plans with better trade-offs among different clinical objectives. Conclusions: The authors have developed a mathematical framework for radiotherapy treatment optimization using voxel-based parameters. The authors can improve the plan quality by adjusting voxel-based weighting factors and exploring the unique and large Pareto surface which include all the Pareto surfaces that can be generated by organ-based model using different objective functions.

62 RADIOLOGY AND NUCLEAR MEDICINE↗

TU-C-12A-11: Comparisons Between Cu-ATSM PET and DCE-CT Kinetic Parameters in Canine Sinonasal Tumors

Purpose: Regions of poor perfusion within tumors may be associated with higher hypoxic levels. This study aimed to test this hypothesis by comparing measurements of hypoxia from Cu-ATSM PET to vasculature kinetic parameters from DCE-CT kinetic analysis. Methods: Ten canine patients with sinonasal tumors received one Cu-ATSM PET/CT scan and three DCE-CT scans prior to treatment. Cu-ATSM PET/CT and DCE-CT scans were registered and resampled to matching voxel dimensions. Kinetic analysis was performed on DCE-CT scans and for each patient, the resulting kinetic parameter values from the three DCE-CT scans were averaged together. Cu-ATSM SUVs were spatially correlated (r{sub spatial}) on a voxel-to-voxel basis against the following DCE-CT kinetic parameters: transit time (t{sub 1}), blood flow (F), vasculature fraction (v{sub 1}), and permeability (PS). In addition, whole-tumor comparisons were performed by correlating (r{sub ROI}) the mean Cu-ATSM SUV (SUV{sub mean}) with median kinetic parameter values. Results: The spatial correlations (r{sub spatial}) were poor and ranged from -0.04 to 0.21 for all kinetic parameters. These low spatial correlations may be due to high variability in the DCE-CT kinetic parameter voxel values between scans. In our hypothesis, t{sub 1} was expected to have a positive correlation, while F was expected to have a negative correlation to hypoxia. However, in wholetumor analysis the opposite was found for both t{sub 1} (r{sub ROI} = -0.25) and F (r{sub ROI} = 0.56). PS and v{sub 1} may depict angiogenic responses to hypoxia and found positive correlations to Cu-ATSM SUV for PS (r{sub ROI} = 0.41), and v{sub 1} (r{sub ROI} = 0.57). Conclusion: Low spatial correlations were found between Cu-ATSM uptake and DCE-CT vasculature parameters, implying that poor perfusion is not associated with higher hypoxic regions. Across patients, the most hypoxic tumors tended to have higher blood flow values, which is contrary to our initial hypothesis. Funding: R01 CA136927.

60 APPLIED LIFE SCIENCES↗

SU-F-P-64: The Impact of Plan Complexity Parameters On the Plan Quality and Deliverability of Volumetric Modulated Arc Therapy with Canonical Correlation Analysis

Purpose: To evaluate the impact of complexity indices on the plan quality and deliverability of volumetric modulated arc therapy (VMAT), and to determine the most significant parameters in the generation of an ideal VMAT plan. Methods: A multi-dimensional exploratory statistical method, canonical correlation analysis (CCA) was adopted to study the correlations between VMAT parameters of complexity, quality and deliverability, as well as their contribution weights with 32 two-arc VMAT nasopharyngeal cancer (NPC) patients and 31 one-arc VMAT prostate cancer patients. Results: The MU per arc (MU/Arc) and MU per control point (MU/CP) of NPC were 337.8±25.2 and 3.7±0.3, respectively, which were significantly lower than those of prostate cancer patients (MU/Arc : 506.9±95.4, MU/CP : 5.6±1.1). The plan complexity indices indicated that two-arc VMAT plans were more complex than one-arc VMAT plans. Plan quality comparison confirmed that one-arc VMAT plans had a high quality than two-arc VMAT plans. CCA results implied that plan complexity parameters were highly correlated with plan quality with the first two canonical correlations of 0.96, 0.88 (both p<0.001) and significantly correlated with deliverability with the first canonical correlation of 0.79 (p<0.001), plan quality and deliverability was also correlated with the first canonical correlation of 0.71 (p=0.02). Complexity parameters of MU/CP, segment area (SA) per CP, percent of MU/CP less 3 and planning target volume (PTV) were weighted heavily in correlation with plan quality and deliveability . Similar results obtained from individual NPC and prostate CCA analysis. Conclusion: Relationship between complexity, quality, and deliverability parameters were investigated with CCA. MU, SA related parameters and PTV volume were found to have strong effect on the plan quality and deliverability. The presented correlation among different quantified parameters could be used to improve the plan quality and the efficiency of the radiotherapy process when creating a complex VMAT plan.

60 APPLIED LIFE SCIENCES↗

SU-F-R-32: Evaluation of MRI Acquisition Parameter Variations On Texture Feature Extraction Using ACR Phantom

Purpose: To investigate the sensitivity of classic texture features to variations of MRI acquisition parameters. Methods: This study was performed on American College of Radiology (ACR) MRI Accreditation Program Phantom. MR imaging was acquired on a GE 750 3T scanner with XRM explain gradient, employing a T1-weighted images (TR/TE=500/20ms) with the following parameters as the reference standard: number of signal average (NEX) = 1, matrix size = 256×256, flip angle = 90°, slice thickness = 5mm. The effect of the acquisition parameters on texture features with and without non-uniformity correction were investigated respectively, while all the other parameters were kept as reference standard. Protocol parameters were set as follows: (a). NEX = 0.5, 2 and 4; (b).Phase encoding steps = 128, 160 and 192; (c). Matrix size = 128×128, 192×192 and 512×512. 32 classic texture features were generated using the classic gray level run length matrix (GLRLM) and gray level co-occurrence matrix (GLCOM) from each image data set. Normalized range ((maximum-minimum)/mean) was calculated to determine variation among the scans with different protocol parameters. Results: For different NEX, 31 out of 32 texture features’ range are within 10%. For different phase encoding steps, 31 out of 32 texture features’ range are within 10%. For different acquisition matrix size without non-uniformity correction, 14 out of 32 texture features’ range are within 10%; for different acquisition matrix size with non-uniformity correction, 16 out of 32 texture features’ range are within 10%. Conclusion: Initial results indicated that those texture features that range within 10% are less sensitive to variations in T1-weighted MRI acquisition parameters. This might suggest that certain texture features might be more reliable to be used as potential biomarkers in MR quantitative image analysis.

60 APPLIED LIFE SCIENCES↗

Data-Driven and Precursor-Group Uncertainty Propagation of Lattice Kinetic Parameters in UAM Benchmark

A new data-driven sampling-based framework was developed for uncertainty quantification (UQ) of the homogenized kinetic parameters calculated by lattice physics codes such as TRITON and Polaris. In this study, extension of the database for the delayed neutron data (DND) is performed by exploring more delayed neutron experiments and adding additional isotopes/actinides to the data libraries. Afterwards, the framework is utilized to obtain a deeper knowledge of the kinetic parameters’ sensitivity and uncertainty. The kinetic parameters include precursor-group-wise delayed neutron fraction (DNF) and decay constant. Input uncertainties include nuclear data (i.e., cross-sections) and DND (i.e., precursor group parameters and fractional delayed neutron yield). It is found that kinetic parameters, especially DNFs, have large uncertainties. The DNF uncertainty is driven by the cross-section uncertainties for LWR designs, while decay constant uncertainty is dominated by the DND uncertainties. The usage of correlated U-235 thermal DND in the UQ process significantly reduces the DND uncertainty contribution on the kinetic parameters. Large void fraction and presence of neutron absorber (e.g., control rod) increase the DNF uncertainty due to the hardening of neutron spectrum. High correlation between the DNF groups ( β 1 , . . , β 6 ) is observed, while the decay constant groups ( λ 1 , . . , λ 6 ) show weak correlation to each other and also to DNF groups. The DNF uncertainties of the dominant precursor group 4 for PWR, BWR, and VVER are about 7.5%, 9.4%, and 7.6%, respectively. The DNF uncertainty grows to larger values after fuel burnup. Kinetic parameters’ values and uncertainties provided here can be efficiently used in subsequent core calculations, point reactor kinetics, and other applications.

21 SPECIFIC NUCLEAR REACTORS AND ASSOCIATED PLANTS↗