Engineering Papers⌕ Search

SEARCH · Engineering Papers

Results for “Reaction history”

Search indexed NASA NTRS and DOE OSTI research on propulsion, heat transfer, battery materials and energy systems. Follow report and document links to the original sources.

Quote a phrase for an exact phrase match. Source license links do not imply unrestricted reuse.

422 records · Page 24

Metasomatic Alteration of Type 3 Ordinary and Carbonaceous Chondrites

Metasomatism refers to the process during which a pre-existing rock undergoes compositional and mineralogical transformations associated with chemical reactions triggered by the reaction of fluids which invade the protolith. It changes chemical compositions of minerals, promotes their dissolution and precipitation of new minerals. In this paper, we review metasomatic alteration of type 3 ordinary (H, L, LL) and carbonaceous (CV, CO, CK) chondrites, including (i) secondary mineralization, (ii) physicochemical conditions, (iii) chronology ( 53 Mn- 53 Cr, 26 Al- 26 Mg, 129 I- 129 Xe) of metasomatic alteration, (iv) records of metasomatic alteration in H, O, N, C, S, and Cl isotopic systematics, (v) effects of metasomatic alteration on O- and Al-Mg-isotope systematics of primary minerals in chondrules and refractory inclusions, and (vi) sources of water ices in metasomatically altered CV, CO, and ordinary chondrites, and outline future studies.

129I-129Xe chronology↗

Simulation study of chemo-mechanical impacts of CO 2 injection in morrow b sandstone reservoir

Here, this study investigates the impacts of geomechanical and geochemical changes on carbon storage in a partially depleted oil reservoir, using results from four different coupled simulation models. Models were used to examine the relative importance of storage mechanisms, and how changing reservoir parameters might affect these mechanisms through time. The study uses data from a Morrowan sandstone reservoir in the Farnsworth Unit (FWU), Ochiltree County, Texas which is currently undergoing CO 2 enhanced oil recovery (EOR). Partially depleted oil reservoirs such as the FWU offer attractive carbon utilization and/or storage targets because of existing infrastructure and economic benefits from incremental oil recovery as well as tax credits. However, prediction of storage capacity or long-term fluid migration in these fields can be difficult because of the wide variation in formation fluids and operational histories that may have undergone. CO 2 injection can cause complex geomechanical and geochemical responses in a reservoir as a result of interplay between dynamic changes in pore pressure, reservoir temperature, fluid composition, and interactions between formation fluids, CO 2 , and reservoir rock. Thus, multiple coupled numerical simulation models must be developed and used to more precisely understand what CO 2 storage mechanisms are most significant, as well as the long-term fate of the stored CO 2 . Our study used results from hydrodynamic, coupled hydro-geomechanical, coupled hydro-geochemical, and coupled hydro-geomechanical-geochemical models to examine how changes in geomechanical and geochemical properties can impact the injectivity or storage capacity of CO 2 . Models simulated historical field operations and then forward-modeled a water-alternate-gas (WAG) operation for 20 years, followed by a 1000-year post-injection monitoring. The work demonstrates that in this specific reservoir, geomechanical impacts appear to be more significant than any geochemical processes, which showed minimal impact on reservoir properties. Furthermore, these simulation scenarios corroborated other studies showing more than 90% of CO 2 injected are being stored and will remain stored in the reservoir. The study was able to draw on a rich set of data from this currently operational project for the work. Because the Morrow is a widespread oil-bearing reservoir in the midcontinent of the United States and is fairly typical of many sandstone reservoirs elsewhere, the study has significance beyond the boundaries of our field area.

58 GEOSCIENCES↗

Structural Interconversion between Agglomerated Palladium Domains and Mononuclear Pd(II) Cations in Chabazite Zeolites

Palladium-exchanged zeolites are candidate materials for passive NO x adsorption in automotive exhaust aftertreatment, where mononuclear Pd cations behave as precursors to the purported NO x adsorption sites. Yet, the structures of zeolite lattice binding sites capable of stabilizing mononuclear Pd 2+ ions, and the mechanisms that interconvert agglomerated PdO and Pd domains into mononuclear Pd 2+ ions during Pd redispersion treatments, remain incompletely understood. In this work, we use a suite of spectroscopic methods and quantitative site titration techniques to characterize mononuclear and agglomerated Pd species on zeolites with varying material properties and treatment history. Aqueous-phase methods to introduce Pd onto NH 4 -form zeolites initially form mononuclear [Pd(NH 3 ) 4 ] 2+ complexes, but subsequent thermal treatments (573–723 K; air) lead to in situ formation of H 2 that first reduces Pd 2+ to metallic Pd domains, which are then oxidized by air to PdO domains. Progressive treatment of Pd-zeolites in air to higher temperatures (723–1023 K) converts larger fractions of agglomerated PdO to mononuclear Pd 2+ , as quantified by H 2 temperature programmed reduction, because higher temperature treatments facilitate Pd redispersion toward deeper locations within chabazite (CHA) crystallites, which is corroborated by complementary titrimetric and spectroscopic data. Pd-CHA zeolites synthesized with similar bulk Pd and framework Al content, but varying framework Al arrangement, provide evidence that six-membered rings (6-MR) hosting paired Al sites (Al–O–(Si–O) x –Al, x = 1, 2) stabilize Pd 2+ ions and that otherwise isolated Al sites can stabilize [PdOH] + species, identifiable by an IR OH stretch at 3660 cm –1 . These findings clarify the underlying chemical processes and gas environments that cause Pd agglomeration in zeolites and their subsequent redispersion to mononuclear Pd 2+ ions, which prefer binding at 6-MR paired Al sites in CHA, and indicate that higher temperature air treatments lead to more uniform Pd spatial distributions throughout zeolite crystallites.

36 MATERIALS SCIENCE↗

Improving Efficacy and Safety of Pharmacological Treatment Through Precision Health and Pharmacogenomics

INTRODUCTION: Future spaceflight will require increased crew medical autonomy as exploration class missions expand in duration and distance from Earth, especially for Mars missions. As mission duration increases, it will be essential to have appropriate amounts of effective medication to ensure the maintenance of crew health and performance. Conversely, mass and volume constraints will become more severe as future spaceflight expands beyond low Earth orbit, where resupply is difficult or becomes impossible. These constraints thus convey an urgency to tailor medications for individual crewmembers and further examine appropriate dosing regimens. BACKGROUND: Precision Health is an exciting area of medicine focused on maintaining an individual’s health and performance through in-depth understanding of an individual’s unique clinical and environmental history, genetic makeup, and molecular profiles. This approach can be adapted to better predict, monitor, and address physiological responses to the spaceflight environment. A subset of this field is pharmacogenomics (PGX), the study of how the expressed genome impacts drug responses with the goal of prescribing the right dose of the right drug at the right time. Specifically, PGX testing provides valuable information on an individual’s precise allelic variations to guide physicians in making informed decisions on drug choice and dosing to avoid adverse events and maximize efficacy. The study goal was to identify which current space pharmacy drugs could be evaluated using PGX testing and to understand the potential impact on the health and wellness of the astronaut population. Additionally, we sought to evaluate clinically available FDA-approved PGX testing solutions to better understand its applicability. METHODS: A complete list of drugs on the ISS was analyzed for risk and likelihood of drug failure and PGX actionability. This analysis encompassed both astronauts’ personal medications, including supplements and over the counter drugs (n=151) contained in the ISS medical accessory kit (IMAK), and ISS MedKit formulary medications (n=95). Duplicate medications and different formulations were removed, which resulted in a total of 157 drugs used in the subsequent analysis. A 5x5 risk assessment table was produced by examining the likelihood of drug failure compared to the consequence of drug failure (LxC). Likelihood of individual drug failure was defined by whether existing processes are sufficient to prevent ineffective treatment or impactful side effect events, as ranked from 1 (very low, can easily be prevented) to 5 (very high, cannot be prevented) during a Mars mission. In contrast, the consequence of drug failure was defined by impact to safety, schedule, cost, or technical criteria and ranked from 1 (very low) to 5 (very high). An assessment of PGX reference laboratories is currently underway to evaluate sample requirements, benefit analysis (cost vs. utility of allele variant analysis), relevance to inflight medication usage, quality of reporting in enabling clinical application, and ease of integration into electronic medical records. RESULTS: Risk assessments (LxC 5x5 table) indicated 128 medications were in the green zone where risk is acceptable, with the remaining 29 of the medications in the yellow or red zone driven predominantly due to drug failure or safety concerns. We found that current PGX testing results could impact 21% of the total medications in the ISS MedKit and IMAK; of these, 9 medications currently have direct clinically actionable guidance available. Results of the clinical PGX solution evaluations as related to these medications will be presented. CONCLUSION: PGX testing has demonstrated clear benefits in terrestrial medicine and clinical environments for the selection of proper medications, avoiding adverse drug reactions, and maximizing drug efficacy. We propose that similar benefits would be bestowed on the astronaut and commercial spaceflight passenger population by performing preemptive preflight PGX testing to reduce risk of mission failure due to ineffective or toxic medications, improve drug efficacy, and further open the door to countermeasure research. For example, PGX results could allow tailoring of specific medications at optimal doses more precisely to each individual astronaut, particularly in areas of space motion sickness, sleep aids, and analgesics. An additional benefit is that PGX results could provide information for better planning of the components of a space pharmacy for deep space missions to be more effective and efficient in the utilization of limited pharmaceutical resources. Finally, while PGX testing of the astronaut corps is not currently conducted, this approach could provide immediate impact in support of mission success by reducing risks, optimizing astronaut performance, and providing valuable insights into long-term astronaut health. Such advancements in clinical decision making are important next steps in building dynamic individual risk profiles for astronauts, increasing selection of the best treatment choice, and providing tailored countermeasures for individual crewmembers.

Pharmacogenomics↗

Designing Peptide Fossils That Model the Evolution of the Bacterial Ferredoxin Fold

Electron transfer coupled to redox chemistry is at the heart of metabolism. The proteins responsible for moving electrons (protein electron carriers) must have emerged at the origin of life. The small iron–sulfur-binding bacterial ferredoxins were likely among these first proteins. Embedded within the ferredoxin sequence and structure is a symmetry that points to an ancient gene duplication event. Little is understood about the nature of ferredoxins prior to this duplication event or what environmental factors may have driven the selection for more complex forms. The deep-time molecular history of ferredoxins goes back billions of years and cannot be reconstructed by phylogenetic analyses based on amino acid sequences. Here, we use structure-guided protein design to model a fossil half-ferredoxin stage in the evolution of this fold, the semidoxins, and their symmetric full-length counterparts, the symdoxins. Semidoxin designs homodimerize, exhibiting structural, thermodynamic, and electrochemical behaviors in most cases identical to cognate symdoxins. However, the semi- and symdoxin fossil stages behave differently when incorporated into an in vivo electron transfer complementation assay. Both can support bacterial growth dependent on protein expression. Growth rates of bacteria expressing the semidoxins are much more sensitive to oxygen than those of bacteria expressing symdoxins. Motivated by the in vivo functionality of designed semidoxins, we identified putative naturally occurring semidoxins in extant anaerobic microorganisms. This is consistent with the observed in vivo oxygen sensitivity of the semidoxin designs. One natural semidoxin is shown to be folded and redox active. However, it exists as a mixture of monomers and dimers, suggesting a potential connection between semidoxins and even simpler single iron–sulfur cluster-binding peptides.

59 BASIC BIOLOGICAL SCIENCES↗

Variational Monte Carlo calculations of n + H 3 scattering

A paramount goal in nuclear physics is to unify ab initio treatments of bound and unbound states. The position-space quantum Monte Carlo (QMC) methods have a long history of successful bound-state calculations in light systems but have seen minimal implementation in unbound systems. Here, we introduce a numerical method to improve the efficiency and accuracy of unbound-state calculations in QMC. As an initial application, we compute scattering observables for the smallest system available to probe three-body forces, the neutron-triton system, using variational Monte Carlo (VMC) wave functions. The method involves inferring long-range amplitudes in the wave function from integrals over the short-range region where all the particles interact. This approach using integral relations is well established in the literature; here, we develop it for the QMC framework. We validate our approach with a consistency check between short-range spectroscopic overlap functions computed from direct evaluation and from the integral relations; scattering amplitudes are long-range asymptotics of those overlaps. Comparison against published benchmark calculations using the same potential demonstrates that when applied to the current VMC wave functions, the integral method produces more accurate scattering observables than direct evaluation from the same variational wave function. However, it still differs noticeably from the exact results. Using additional interactions, we then present phase shifts and mixing parameters for the n + 3 H system. In particular, we present one of the first applications of the Norfolk family of local coordinate-space chiral potentials in unbound systems of A > 2. The Norfolk results accurately describe s-wave scattering but predict p-wave cross sections too large. Compared with previous QMC scattering calculations, the integral method avoids difficulties associated with the precise computation of energy differences and with convergence outside the interaction region, which is particularly severe in the variational calculation. Application of the integral method here paves the way for its use in Green's function Monte Carlo (GFMC) calculations. In GFMC, the wave functions are more accurate, but the high-precision convergence of their tails is slow, and there are additional difficulties in reading out amplitudes. Here, the integral methods will address both of those remaining problems.

73 NUCLEAR PHYSICS AND RADIATION PHYSICS↗

Qualitative Headspace GCMS Analysis of Lunar Regolith and Volatile Simulant Mixtures

Introduction: Future Artemis missions aim to return the volatile-bearing samples collected near lunar polar craters. We, as advanced curation scientists, are responsible for developing techniques and methodologies for preserving the integrity of returned samples and the science value those samples contain. The extent to which that preservation is possible, and the trade-offs preservation requires (e.g. monetary costs, sample volume limitations) all must be considered. Even less-than pristine volatile-bearing samples will be of tremendous value to the scientific community seeking to unravel the history of lunar surface volatiles and, more broadly, volatiles in the solar system. A sample collected on the lunar surface will experience at least five distinctive periods during which any changes here referred to as “alteration” will certainly occur at some scale: collection on the lunar surface; transportation back to Earth; long-term storage; curatorial processing; and allocation/distribution. The Planetary Exploration and Astromaterials Research Lab (PEARL) seeks to understand temperature and pressure effects on returned volatile samples by working with high-fidelity volatile-containing regolith simulants, setting the foundation for the future of cold curation. This abstract is focused on gas-surface interactions between LCROSS volatiles and readily available lunar regolith simulants. Experiments involved analyzing differences in headspace gas composition for various combinations of volatile and regolith simulants using gas chromatography/mass spectrometry (GC/MS). Experimental Procedure: The volatile simulants were chosen based on the molecules detected during the LCROSS mission.1 Stock solutions of condensed lunar volatile analytes were: methanol, 7 N ammonia in methanol, and 0.4% hydrogen sulfide in water. The regolith simulants used were primarily JSC-1A and NU-LHT-4M. Additional regolith simulant control studies were conducted with <150 μm sieved sand and KBr. A nested vial sample preparation approach separated the liquid stock solutions from the regolith, eliminating potential matrix effects between liquid and solid phases. Fifteen microliter aliquots of liquid volatile simulants were added to a 2 mL liquid GC vial and capped in atmosphere. An 18G needle punctured the 2 mL GC vial immediately before being transferred and sealed in a 20 mL GC vial containing 0-0.3 g of regolith simulant, see Figure 1. Separating the analytes ensures any changes observed in the total headspace gases is a result of gas-surface and/or gas-gas interactions. Equipment and Method: Initial GC/MS method development for the separation and identification of relevant headspace gases can be found in Amick, et al. 2023.2 The only hardware change is a different column: a TG-1701MS 30 m × 0.25 mm × 1.00 μm column. The vials were sampled at 10°C, room temperature (~25°C) and 50°C. Low temperature samples were kept in a chilled autosampler stage for at least 1 hour prior to sampling. High temperature samples were agitated at 50°C for 5 minutes immediately prior to injection onto the column. Headspace chromatograms were collected for each combination of temperature, regolith, and volatile simulant, including controls without one or both types of analytes, in triplicate. The chromatogram elution window for each analyte or significant atmospheric gas was identified using the peak mass spectrum cross-referenced with Figure 1.Picture of the nested vial set-up. a NIST MS library search. Each analyte peak was integrated after filtering the mass spectrum trace for the parent or most unique mass-to-charge ratio. For example, the mass-to-charge ratio used to identify, filter for, and integrate the carbon dioxide peak was centered around 44 m/z. Results: Figure 2 shows the integrated peak area for hydrogen sulfide in all combinations of regolith simulants, temperatures, and the addition of ammonia in methanol solution. Multiple repeat experiments with H2S and regolith simulants have confirmed hydrogen sulfide is removed from the headspace within 1 hour when exposed to JSC-1A, NU-LHT-4M and sand (not pictured). The consumption of H2S by lunar regolith simulants at different temperatures indicates surface chemistry will be an integral component in sample integrity and preservation. It is important to note that while the effect of surface chemistry on gaseous hydrogen sulfide is intriguing, further investigation into more chemically accurate regolith simulants is necessary and ongoing. The sulfur in hydrogen sulfide is in its most reduced state while off-the-shelf, terrestrially sourced JSC-1A and NU-LHT-4M are more oxidized than most lunar materials,3which likely leads to different oxidation-reduction reactions than would be expected in lunar regolith. Figure 3 shows the integrated peak area of carbon dioxide for each sample combination that contained ammonia in methanol solution. The addition of ammonia to the GC vials results in a consistent and reproducible decrease in carbon dioxide gas, even at 50°C. The effect became more pronounced when JSC-1A or NU-LHT-4M were present. This set of experiments demonstrated that the sample composition will affect the chemical and physical state of each component present. Future spectroscopic and microscopy experiments will be geared towards identifying the cause for the CO2(g) concentration decrease and the consumption of hydrogen sulfide. As cold and volatile curation scientists, this information provides necessary insight on how to appropriately handle and analyze volatile bearing returned samples, as well as predict the effect chemical composition has on the various sample phases we will analyze upon return to Earth. Unlike traditional curation of geologic materials, the molecules in a sample cannot be identified or processed using the naked eye or even an optical microscope. Volatile curation will require a combination of analytical techniques, including but not limited to highly sensitive gas and solid/condensed phase spectroscopy. This set of experiments has demonstrated the need for more detailed studies of volatile mixtures with mineralogically and geochemically analogous lunar regolith simulants to prepare for the curation of volatile-rich lunar samples from the south polar region of the Moon. References: [1] Colaprete, A., et al. (2010) Science, 330, (463-468). [2] Amick, C. L., et al.(2023) Houston, Texas, [3] Heiken, G. H., et al.(1991) (778-778)

Cecilia L Amick↗

GC/MS Method Development for Separating Lunar Volatile Ice Simulant Headspace Gases

Various investigators propose the lunar surface contains widely distributed volatiles, especially water- like species, i.e. OH and H2O. Surface volatiles are theorized to exist as a hydrated regolith layer, concentrated in extremely cold polar permanently shadowed regions (PSR), and/or solar wind implantation reservoirs in lunar glasses. The proposed sources of lunar surface volatiles range from cometary impacts, solar wind, or a supply present during moon formation. Future Artemis missions aim to collect and return the samples containing volatiles collected near lunar polar craters or PSRs. We, as advanced curation scientists, are responsible for developing techniques and methodologies for preserving returned sample integrity as much as possible. Pristine volatile-bearing samples are invaluable to the scientific community seeking to unravel the history of the solar system. Realistically, a sample will experience alteration during collection, transportation back to earth, and storage. The Planetary Exploration and Astromaterials Research Lab (PEARL) seeks to understand temperature and pressure effects on high-fidelity volatile-containing regolith simulants, the foundation for the future of cold curation. This abstract outlines the separation, identification, and quantification of headspace gases over volatile ice feed stock material using gas chromatography/mass spectrometry (GC/MS). Preliminary objectives concentrated on sample handling, reproducibility, and understanding the elution characteristics for each analyte. Initial GC/MS method development experiments utilized diluted static headspace sample preparation. Diluted samples were used because sampling headspace gases directly from a vial containing liquid analyte resulted in overloading of the column and detector. Overloading is evident based on chromatogram peak shapes and instrument contamination, or carry over, between experiments. A mixture of three alcohols were used for a majority of the sample handling and reproducibility studies. Reproducibility was tested via multiple users, calibration curves, and check standards. Stock solutions of condensed lunar volatile analytes included methanol, ammonia in methanol, hydrogen sulfide in water, and an equal volume mixture of methanol, ethanol, and isopropanol. Current samples use room air as the headspace sample matrix, however future experiments will incorporate an inert purge gas, such as argon or nitrogen. Three mL of each analyte solution were capped in separate 20 mL crimp top GC vials. Dilutions were carried out by removing an aliquot of headspace gases with a calibrated 1 mL gastight syringe and immediately transferring to a 20 mL capped crimp top vial. The GC/MS is a Thermo Fisher Trace 1310/ISQ 7000 with a TriPlus RSH autosampler and split/splitless injector module. The experiments outlined in this abstract use the following hardware: a 2.5 mL gastight headspace syringe tool, 1 mm ID x 78.5 mm length ultra-inert straight injection liner, and a TG-BondQ 30 m × 0.32 mm × 10 μm column. Various parameters, such as hardware selection and the temperature, pressure, and split ratio set points, continue to evolve as the overall experiment is refined. Diluted headspace chromatograms were collected for the individual stock solutions. Retention times, peak shapes, and mass spectra were evaluated and added to the data processing method for each molecule of interest. Figure 1 shows the total ion chromatograms for the three major lunar volatile simulant stock solutions: methanol, 7 N ammonia in methanol, and 0.4% hydrogen sulfide in water. Tailing peak shapes for ammonia (2.98 min rt) and water (4.06 min rt) indicate the molecules are not properly eluting from the selected column with the current separation method. Additionally, hydrogen sulfide and ammonia have overlapping peak windows, which could impact quantification. Ongoing experiments aim to address the peak shape and overlapping via the separation method and hardware selection. Sample preparation reproducibility experiments used stock solution containing equal volumes of a non- interactive mixture of methanol, ethanol, and isopropanol. Mass spectrum ion traces were used to identify and quantify all three alcohols. Peaks were automatically detected, identified, and integrated through the mass spectra detection and processing parameters. Calibration response curves and check standards were used to evaluate the validity of the sample preparation procedure. Figure 2 shows the methanol chromatogram peak area versus total headspace dilution volume transferred from the alcohol mixture vial. The calibration response curves and check standards validate sample preparation procedure. Continuing data analysis efforts are working towards correlating the peak area and instrument response factor to the headspace analyte concentration and condensed phase composition. Static headspace gas chromatography theory relies on Dalton’s law, Raoult’s law, Henry’s Law, and the Kolb and Ettre equation to associate peak area to the analyte composition in a non-ideal solution. Equation 1 is a simplified expression derived from the aforementioned theories. Future experiments involve liquid injections of the individual stock solutions, liquid and headspace analysis of various stock solution combinations, and the addition of regolith simulants to the mixtures. Temperature is another variable expected to affect reaction rates and will be explored.

Cecilia L. Amick↗