Engineering Papers⌕ Search

SEARCH · Engineering Papers

Results for “Radiation Detection”

Search indexed NASA NTRS and DOE OSTI research on propulsion, heat transfer, battery materials and energy systems. Follow report and document links to the original sources.

Quote a phrase for an exact phrase match. Source license links do not imply unrestricted reuse.

At least 433 records · Page 24

It’s Not What You Take Up, It’s What You Keep: How Discoveries from Diverse Disciplines Directed the Development of the FDG PET/CT Scan

Although imaging glucose metabolism with positron emission tomography combined with X-ray CT (FDG-PET/CT) has become a standard diagnostic modality for the discovery and surveillance of malignant tumors and inflammatory processes, its origins extend back to more than a century of notable discoveries in the fields of inorganic and organic chemistry, nuclear physics, mathematics, biochemistry, solute transport physiology, metabolism, and imaging, accomplished by pioneering and driven investigators, of whom at least ten were recipients of the Nobel Prize. These tangled and diverse roots eventually coalesced into the FDG-PET/CT method, that through its many favorable characteristics inherent in the isotope used ( 18 F), the accurate imaging derived from coincidence detection of positron annihilation radiation combined with computed tomography, and the metabolic trapping of 2-deoxy-2-[ 18 F] fluoro-d-glucose (FDG) in tissues, provides safety, sensitivity, and specificity for tumor and inflammation detection. Here, the authors hope that this article will increase the appreciation among its readers of the insight, creativity, persistence, and drive of the many investigators who made this technique possible. This article is followed by a review of the many applications of FDG-PET/CT to the gastrointestinal tract and hepatobiliary system (Mandelkern in Dig Dis Sci 2022)

2-DG↗

Variable energy X-ray fluorescence source

Here we detail the design of a variable energy, x-ray fluorescence source using a low activity (1.8×10 6 dpm) 99 Tc β source that irradiates thin foils. By rotating the source among foils of Ti, Zn, Nb, Ag, and Au, the device produces x rays between 4 and 70 keV at a rate near 1 Hz. When the source is placed in a storage position, the external radiation is non-detectable. The design of the shielding and rotation mechanism permits use in vacuum and at liquid nitrogen temperature. The design is intended for the study of the low energy response to radiation impinging upon Ge detector surfaces. The source will be useful for understanding the detector response in large-scale Ge arrays such as MAJORANA and LEGEND.

47 OTHER INSTRUMENTATION↗

A new water-based scintillator for efficient Cherenkov and scintillation separation

Neutrinos offer a unique window into the world around us, allowing us to probe otherwise unreachable regions like the interior of stars and the depths of the earth, as well as potentially offering a mechanism for monitoring nuclear activity. Both pure-water and organic liquid scintillators have been used as the detection medium of large-scale neutrino detectors. Organic liquid scintillators offer higher sensitivity at lower energies, which is desirable for many applications, but detection of the Cherenkov radiation required for directional sensitivity is very difficult. A possible solution is to use water-based liquid scintillators (WbLSs), where some fraction of the water is replaced with a micellar solution of the liquid scintillator. This can enhance the detection sensitivity beyond that of pure water, without significantly affecting the ability to leverage the topological Cherenkov signature. Very specific scintillation properties are required to achieve this goal: the scintillation decay time should be significantly slower than that of the Cherenkov emission, so timing-based discrimination of Cherenkov light from scintillation can be applied. At the same time, the light yield should be high enough to enhance the overall sensitivity of the detector, but without losing too much of the Cherenkov light. In this study, we report a new water-based liquid scintillation cocktail based on a 9-methylcarbazole fluorescent dye and a linear alkylbenzene solvent. Here, the proposed composition offers 13.8 ns scintillation decay time and 368 nm emission that matches the desired properties.

Wolszczak, Weronika W. [Lawrence Berkeley National↗

Methods and systems for electromagnetic near-field coherent sensing

The present disclosure may be embodied as methods and/or systems for non-contact measuring of an on-body and/or inside-body motion of an individual. A sensing signal is provided within a near-field coupling range of a motion to be measured. In this way, a measurement signal may be generated as the sensing signal modulated by the motion. The sensing signal may be an ID-modulated signal. In some embodiments, the sensing signal is a backscattered RFID link provided a wireless tag. A downlink signal may be provided to power the wireless tag. The sensing signal may be a harmonic of the downlink signal. The measurement signal is detected. The motion is measured based on the measurement signal. The measurement signal may be detected as far-field radiation after transmission through a source of the motion. The measurement signal may be detected as reflected from a source of the motion as antenna reflection.

Hui, Xiaonan↗

A room-temperature polarization-sensitive CMOS terahertz camera based on quantum-dot-enhanced terahertz-to-visible photon upconversion

Detection of terahertz (THz) radiation has many potential applications, but presently available detectors are limited in many aspects of their performance, including sensitivity, speed, bandwidth and operating temperature. Most do not allow the characterization of THz polarization states. Recent observation of THz-driven luminescence in quantum dots offers a possible detection mechanism via field-driven interdot charge transfer. Here, we demonstrate a room-temperature complementary metal–oxide–semiconductor THz camera and polarimeter based on quantum-dot-enhanced THz-to-visible upconversion mechanism with optimized luminophore geometries and fabrication designs. Besides broadband and fast responses, the nanoslit-based sensor can detect THz pulses with peak fields as low as 10 kV cm–1. A related coaxial nanoaperture-type device shows a to-date-unexplored capability to simultaneously record the THz polarization state and field strength with similar sensitivity.

77 NANOSCIENCE AND NANOTECHNOLOGY↗

Ionizing Radiation Sensing with Functionalized and Copper-Coated SWCNT/PMMA Thin Film Nanocomposites

This paper studies the ionizing radiation effects on functionalized single-walled carbon nanotube (SWCNT)/poly(methyl methacrylate) (PMMA) thin-film nanocomposites [SWNT/PMMA]. The functionalized thin-film devices are made of ferrocene-doped SWCNTs, SWCNTs functionalized with carboxylic acid (COOH), and SWCNTs coated/ modified with copper. The nanocomposite was synthesized by the solution blending method and the resulting nanocomposite was spin-cast on interdigitated electrodes (IDEs). A 160 kV X-ray source was used to irradiate the thin film and changes in the electrical resistance of the nanocomposites due to X-rays were measured using a semiconductor device analyzer. Carboxylic acid functionalized and copper-coated SWCNT/PMMA nanocomposite showed a reduced response to X-rays compared to unfunctionalized SWCNT/PMMA nanocomposite. Ferrocene-doped SWCNT showed a higher sensitivity to X-rays at lower dose rates. This is in contrast to a previous study that showed that similar nanocomposites using functionalized multi-walled CNTs (MWCNTs) had demonstrated an improved response to X-rays ionizing radiation compared to unfunctionalized MWCNTs for all dose rates. Electrical measurements were also performed using the Arduino Nano microcontroller. The result showed that a relatively economical, lightweight-designed prototype radiation sensor based on SWCNT/PMMA thin-film devices could be produced by interfacing the devices with a modest microcontroller. This work also shows that by encapsulating the SWCNT/PMMA thin-film device in a plastic container, the effect of ambient humidity can be reduced and the device can still be used to detect X-ray radiation. This study further shows that the sensitivity of SWCNT to X-rays was dependent on both the functionalization of the SWCNT and the dose rate.

36 MATERIALS SCIENCE↗

Detection Limits and Near‐Field Ground Motions of Fast and Slow Earthquakes

Abstract We investigate theoretical limits to detection of fast and slow seismic events, and spatial variations of ground motion expected from M 6 earthquakes at short epicentral distances. The analyses are based on synthetic velocity seismograms calculated with the discrete wavenumber method assuming seismic velocities and attenuation properties of the crust in Southern California. The examined source properties include different magnitudes ( M −1.0 to M 6.0), static stress drops (0.1–10 MPa), and slow and fast ruptures (0.1–0.9 of shear wave velocity). For the M 6 events we also consider variations in rise times producing crack‐ and pulse‐type events and different rupture directivities. Slow events produce ground motion with considerably lower amplitude than corresponding regular fast earthquakes with the same magnitude, and hence are significantly more difficult to detect. The static stress drop and slip rise time also affect the maximum radiated seismic motion, and hence event detectability. Apart from geometrical factors, the saturation and depletion of seismic ground motion at short epicentral distances stem from radiation pattern, earthquake size (magnitude, stress drop), and rupture directivity. The rupture velocity, rise time, and directivity affect significantly the spatial pattern of the ground motions. The results can help optimizing detection of slow and fast small earthquakes and understand the spatial distribution of ground motion generated by large events.

58 GEOSCIENCES↗

Low temperature process for diode termination of fully depleted high resistivity silicon radiation detectors that can be used for shallow entrance windows and thinned sensors

Fabrication of vertical diodes for radiation sensing using a low temperature microwave anneal is provided. This kind of anneal allows the back side processing to be performed after the front side processing is done without damaging the front side structures. This enables a simplified fabrication of thinned detectors compared to a conventional silicon on insulator process. Another feature that this technology enables is a thin entrance window for a detector that also serves as the doped diode termination. Such thin entrance windows are especially suitable for detection of low energy radiation.

Kenney, Christopher J.↗

Project 8: Measuring the tritium beta-decay spectrum using Cyclotron Radiation Emission Spectroscopy

Abstract. The goal of the Project 8 experiment is to measure the absolute neutrino mass using tritium beta decays and a new spectroscopic technique, Cyclotron Radiation Emission Spectroscopy (CRES). The first phase of Project 8 demonstrated that CRES could be used to detect single-electron cyclotron radiation and perform precision electron spectroscopy. We are in Phase II of the experiment, performing a 100-day measurement of the endpoint of the tritium spectrum. We will demonstrate the ability to measure the last ~2 keV of the beta-decay spectrum and explore the background rate at energies just above the endpoint; CRES has the potential for extremely low backgrounds. In Phase III we will demonstrate the ability to scale up the volume of the experiment. In Phase IV we will switch the source from molecular tritium to atomic tritium, which will avoid systematic uncertainties from the final states of the molecule. I will present the current status of Project 8 Phase II and the plans for Phases III and IV.

Oblath, Noah↗

Investigations of radiation damaged arranged scintillating particle composites

Composites consisting of periodically arranged scintillating particles within an acrylic (poly methyl methacrylate) matrix are excellent templates for the gamma-insensitive detection of fast neutrons. In order to study the impact of radiation damage on acrylic-based scintillating particle composites, we exposed acrylic samples to different doses of fast neutrons up to 119.7 kGy and investigated the change in optical characteristics using optical absorption spectroscopy in the 200–800 nm wavelength range. The experimental results are compared to coupled MCNP6 and optical ray-tracing (FRED) simulations, and qualitative agreement is found. Neutron-induced radiation damage in the acrylic matrix manifests as a red-shift in the ultra-violet absorption edge of the acrylic and a corresponding decrease in the light propagation efficiency, which leads to detector performance degradation. We show for the first time that the effects of radiation damage can be mitigated by the use of wavelength-shifting coatings. We predict that composites with wavelength-shifting coatings can enable neutron detectors with high tolerance against neutron-induced radiation damage, a property that is particularly desired for neutron detection in high radiation environments.

36 MATERIALS SCIENCE↗

A detailed experimental and modeling comparison of molecular radiative heat loss in a spark-ignition engine

Radiative heat transfer has been chiefly considered negligible in internal combustion engines, except for Diesel engines where soot radiation was recognized as a significant radiative transfer source. Only more recently, detailed simulations have shown that molecular radiation can be substantial as well. In extension to this, molecular radiative heat transfer can reach detectable levels of about 5–10% of the total heat transfer in spark-ignited engines. The broadband radiative nature of the significant emitting molecules, carbon dioxide and water, makes it necessary to address whether radiative trapping plays a substantial role in either total heat loss or energy redistribution within the cylinder. An experimental setup that allows measurements of the infrared emissions at a 2-crank-angle-degree resolution was developed to determine the importance of radiative trapping by carbon dioxide and water. Measurements were conducted in the well-characterized and documented TCC-III engine at the University of Michigan. The engine operated on a stoichiometric propane/air mixture at a speed of 1,300 RPM. Large Eddy Simulations with added line-by-line photon Monte-Carlo simulations of the molecular radiation were an integral part of this study to plan and devise the measurements. Post-processing of the simulation data included an accurate representation of the experimental volume from where infrared signals are collected. Additionally, the experimental data were used for validation of the photon Monte-Carlo simulations. Joint analysis of experimental and simulated spectra allowed quantifying the significance of radiative trapping. Results show the significant role of radiative trapping when predicting radiative heat transfer in the TCC-III engine.

42 ENGINEERING↗

Narrowing lab–to–market gaps: Device innovations in fuel generation, solar–cell, and photodetection

Academic translational research efforts to industry are often an underlying sought–after goal among various researchers. Through the interchanges of research endeavors between academia–industry, great innovations can/has been achieved that cater to the real–world application by bridging “industrially relevant” problem solving with pursuing fundamental studies. It is pertinent that most of the studies from university–level research works may not translate into demonstrable market products due to various reasons. Funding support, individual researcher goals, socioeconomic factors, and most importantly the technical know–how of generating revenue strategies for startups, are a few of the factors that have slowed the pace of collaborative efforts. However, we believe that the most crucial component is the identification of the critical parameters that solve long–standing problems that hinder the scale–up of the lab scale research into marketable products considering the techno–economic analysis. Here, to illustrate this, we take the three most relevant examples of devices for fuel generation, devices to utilize solar radiation, and devices for detection and other related applications. In this perspective, we provide an in–depth case study of each of these critical parameters to comment on the direction of research avenues that can serve as step–stones for the commercialization of university–level lab research studies.

42 ENGINEERING↗

Inline gamma-spectrometry of fission product elements after rapid high-pressure ion chromatographic separation

Analysis of irradiated material shortly after irradiation can be non-trivial due to highly radioactive activation and fission isotopes increasing dead time in gamma-ray detection systems, often requiring a “cooling-period” between receipt of a sample and the subsequent analysis. A direct separation–detection method has been developed combining ion chromatography and inductively coupled mass spectrometry for rapid, low-level analysis of fission products; it cannot, however, detect certain short-lived species below the detection limit of the system. In this paper we report the implementation of an inline gamma-ray detector, which was added post-separation, pre-analysis, to test the quality and utility of elementally-isolated gamma-ray spectroscopy.

Inline gamma-ray detection↗

Extracting the electronic structure of light elements in bulk materials through a Compton scattering method in the readily accessible hard x-ray regime

Here, our Compton profile measurements of Ti and TiH 2 using readily available hard X-ray radiation at 27.5 keV, detected by both a Hitachi Vortex silicon-drift detector and a high-resolution superconducting transition-edge sensor array, are found to be in excellent accord with state-of-the-art density functional theory based calculations. The spherically averaged difference between the Compton profiles of TiH 2 and Ti is well described by an inverted parabola, supporting an itinerant behavior of the electron gas screening the protons in the Ti matrix. Our experimental approach, validated by two different detectors, extends the applicability of Compton scattering technique to the readily accessible hard x-ray regime (below 30 keV). Our study suggests possibilities for experiments at low-flux bending magnet synchrotron beamlines and paves the way for the development of tabletop Compton experiments with x-ray tubes.

36 MATERIALS SCIENCE↗

Theory of topological exciton insulators and condensates in flat Chern bands

Excitons are the neutral quasiparticles that form when Coulomb interactions create bound states between electrons and holes. Due to their bosonic nature, excitons are expected to condense and exhibit superfluidity at sufficiently low temperatures. In interacting Chern insulators, excitons may inherit the nontrivial topology and quantum geometry from the underlying electron wavefunctions. We theoretically investigate the excitonic bound states and superfluidity in flat-band insulators pumped with light. We find that the exciton wavefunctions exhibit vortex structures in momentum space, with the total vorticity being equal to the difference of Chern numbers between the conduction and valence bands. Moreover, both the exciton binding energy and the exciton superfluid density are proportional to the Brillouin-zone average of the quantum metric and the Coulomb potential energy per unit cell. Spontaneous emission of circularly polarized light from radiative decay is a detectable signature of the exciton vorticity. We propose that the vorticity can also be experimentally measured via the nonlinear anomalous Hall effect, whereas the exciton superfluidity can be detected by voltage-drop quantization through a combination of quantum geometry and Aharonov–Casher effect. Topological excitons and their superfluid phase could be realized in flat bands of twisted Van der Waals heterostructures.

Science & Technology - Other Topics↗

Drone Video Platform—Collision Avoidance, Situational Awareness, and Communications

Small unmanned aerial systems are ideal for delivering sensors into areas that are inaccessible or too dangerous for human entry or manned aircraft over-flights. The systems can fly low and slow for enhanced sensitivity and in tight spaces where ordinary aircraft could never fit. We have configured and flown sensor payloads for radiation, chemical, and optical detection on small fixed-wing and rotary-wing aircraft. All the sensor packages provide telemetry, GPS coordinates, LIDAR distance ranging, and absolute time of day to microsecond accuracy. Payload weights range from less than 1 kg up to 5.5 kg. Currently, communications are over 2.4 GHz and 915 MHz radios, as well as over 4G LTE cellular data links. Real-time data feeds from the sensor payloads to web browser clients anywhere in the world are possible via a virtual EC2 server on the Amazon AWS cloud. In FY 2019, the Nevada National Security Site teamed with Virginia Tech, H3D Corp., and Unmanned Systems, Inc. to accomplish the four flight missions described in this report. A large part of this year’s mission goals were to demonstrate the ability to fly beyond visual line of sight (BVLOS).

46 INSTRUMENTATION RELATED TO NUCLEAR SCIENCE AND ↗

An Overview of Emerging Nuclear Sensor Technologies: Challenges, Advancements and Applications

Nuclear sensors are essential for detecting and measuring nuclear radiation in various applications, including nuclear power plants, medical imaging, and environmental monitoring. Traditional nuclear sensors have served these fields for decades, but recent advancements in emerging sensor technologies offer novel improvements in accuracy, sensitivity, and reliability. This review presents an up-to-date overview of recent progress in the advancements of nuclear sensor technologies, their diverse applications, challenges in implementation, and opportunities for future research.

46 INSTRUMENTATION RELATED TO NUCLEAR SCIENCE AND ↗

Powerful Radio Sources in the Southern Sky. II. A Swift X-Ray Perspective

We recently constructed the G4Jy-3CRE, a catalog of extragalactic radio sources based on the GLEAM 4-Jy (G4Jy) sample, with the aim of increasing the number of powerful radio galaxies and quasars with similar selection criteria to those of the revised release of the Third Cambridge Catalog (3CR). The G4Jy-3CRE consists of a total of 264 radio sources mainly visible from the Southern Hemisphere. Here, we present an initial X-ray analysis of 89 G4Jy-3CRE radio sources with archival X-ray observations from the Neil Gehrels Swift Observatory. We reduced a total of 624 Swift observations, for about 0.9 Ms of integrated exposure time. We found X-ray counterparts for 59 radio sources belonging to the G4Jy-3CRE, nine of them showing extended X-ray emission. The remaining 30 sources do not show any X-ray emission associated with their radio cores. Our analysis demonstrates that X-ray snapshot observations, even if lacking uniform exposure times, as those carried out with Swift, allow us to (i) verify and/or refine the host galaxy identification; (ii) discover the extended X-ray emission around radio galaxies of the intracluster medium when harbored in galaxy clusters, as the case of G4Jy 1518 and G4Jy 1664; and (iii) detect X-ray radiation arising from their radio lobes, as for G4Jy 1863.

79 ASTRONOMY AND ASTROPHYSICS↗