Engineering Papers⌕ Search

SEARCH · Engineering Papers

Results for “RELEASE”

Search indexed NASA NTRS and DOE OSTI research on propulsion, heat transfer, battery materials and energy systems. Follow report and document links to the original sources.

Quote a phrase for an exact phrase match. Source license links do not imply unrestricted reuse.

At least 433 records · Page 24

Steady and transient fluid shear stress stimulate NO release in osteoblasts through distinct biochemical pathways

Fluid flow has been shown to be a potent stimulus in osteoblasts and osteocytes and may therefore play an important role in load-induced bone remodeling. The objective of this study was to investigate the characteristics of flow-activated pathways. Previously we reported that fluid flow stimulates rapid and continuous release of nitric oxide (NO) in primary rat calvarial osteoblasts. Here we demonstrate that flow-induced NO release is mediated by shear stress and that this response is distinctly biphasic. Transients in shear stress associated with the onset of flow stimulated a burst in NO production (8.2 nmol/mg of protein/h), while steady flow stimulated sustained NO production (2.2 nmol/mg of protein/h). Both G-protein inhibition and calcium chelation abolished the burst phase but had no effect on sustained production. Activation of G-proteins stimulated dose-dependent NO release in static cultures of both calvarial osteoblasts and UMR-106 osteoblast-like cells. Pertussis toxin had no effect on NO release. Calcium ionophore stimulated low levels of NO production within 15 minutes but had no effect on sustained production. Taken together, these data suggest that fluid shear stress stimulates NO release by two distinct pathways: a G-protein and calcium-dependent phase sensitive to flow transients, and a G-protein and calcium-independent pathway stimulated by sustained flow.

Non-NASA Center↗

Effects of methiothepin on changes in brain serotonin release induced by repeated administration of high doses of anorectic serotoninergic drugs

We previously observed, using in vivo microdialysis, that the potassium-evoked release of frontocortical serotonin (5-HT) is suppressed after rats receive high doses (30 mg/kg, i.p., daily for 3 days) of fluoxetine, a selective blocker of 5-HT reuptake. We now describe similar impairments in 5-HT release after repeated administration of two other 5-HT uptake blockers, zimelidine and sertraline (both at 20 mg/kg, i.p. for 3 days) as well as after dexfenfluramine (7.5 mg/kg, i.p. daily for 3 days), a drug which both releases 5-HT and blocks its reuptake. Doses of these indirect serotonin agonists were about 4-6 times the drug's ED50 in producing anorexia, a serotonin-related behavior. In addition, methiothepin (20 microM), a non-selective receptor antagonist, locally perfused through the dialysis probe 24 h after the last drug injection, enhanced K(+)-evoked release of 5-HT at serotoninergic nerve terminals markedly in control rats and slightly in rats treated with high doses of dexfenfluramine or fluoxetine. On the other hand, pretreatment with methiothepin (10 mg/kg, i.p.) one hour before each of the daily doses of fluoxetine or dexfenfluramine given for 3 days, totally prevented the decrease in basal and K(+)-evoked release of 5-HT. Finally, when methiothepin was injected systemically the day before the first of 3 daily injections of dexfenfluramine, it partially attenuated the long-term depletion of brain 5-HT and 5-HIAA levels induced by repeated administration of high doses of dexfenfluramine. These data suggest that drugs which bring about the prolonged blockade of 5-HT reuptake - such as dexfenfluramine and fluoxetine - can, by causing prolonged increases in intrasynaptic 5-HT levels as measured by in vivo microdialysis, produce receptor-mediated long-term changes in the processes controlling serotonin levels and dynamics.

NASA Discipline Regulatory Physiology↗

Influence of Finite Element Software on Energy Release Rates Computed Using the Virtual Crack Closure Technique

Strain energy release rates were computed along straight delamination fronts of Double Cantilever Beam, End-Notched Flexure and Single Leg Bending specimens using the Virtual Crack Closure Technique (VCCT). Th e results were based on finite element analyses using ABAQUS# and ANSYS# and were calculated from the finite element results using the same post-processing routine to assure a consistent procedure. Mixed-mode strain energy release rates obtained from post-processing finite elem ent results were in good agreement for all element types used and all specimens modeled. Compared to previous studies, the models made of s olid twenty-node hexahedral elements and solid eight-node incompatible mode elements yielded excellent results. For both codes, models made of standard brick elements and elements with reduced integration did not correctly capture the distribution of the energy release rate acr oss the width of the specimens for the models chosen. The results suggested that element types with similar formulation yield matching results independent of the finite element software used. For comparison, m ixed-mode strain energy release rates were also calculated within ABAQUS#/Standard using the VCCT for ABAQUS# add on. For all specimens mod eled, mixed-mode strain energy release rates obtained from ABAQUS# finite element results using post-processing were almost identical to re sults calculated using the VCCT for ABAQUS# add on.

Krueger, Ronald↗

Strategies to Mitigate Ammonia Release on the International Space Station

International Space Station (ISS) is crucial to its continuous operation. Off-nominal situations can arise from virtually any aspect of ISS operations. One situation of particular concern is the inadvertent release of a chemical into the ISS atmosphere. In sufficient quantities, a chemical release can render the ISS uninhabitable regardless of the chemical s toxicity as a result of its effect on the hardware used to maintain the environment. This is certainly true with system chemicals which are integral components to the function and purpose of the system. Safeguards, such as design for minimum risk, multiple containment, hazard assessments, rigorous safety reviews, and others, are in place to minimize the probability of a chemical release to the ISS environment thereby allowing the benefits of system chemicals to outweigh the risks associated with them. The thermal control system is an example of such a system. Heat generated within the ISS is transferred from the internal thermal control system (ITCS) to the external thermal control system (ETCS) via two, single-barrier interface heat exchangers (IFHX). The ITCS and ETCS are closed-loop systems which utilize water and anhydrous ammonia, respectively, as heat-transfer fluids. There is approximately 1200 lbs. (208 gallons) of anhydrous ammonia in the ETCS circulating through the two heat exchangers, transferring heat from the ITCS water lines. At the amounts present in the ETCS, anhydrous ammonia is one system chemical that can easily overwhelm the station atmosphere scrubbing capabilities and render the ISS uninhabitable in the event of a catastrophic rupture. Although safeguards have certainly minimized the risk of an ammonia release into the Station atmosphere, credible release scenarios and controls to manage these scenarios are examined.

Macatangay, Ariel V.↗

Self-locking double retention redundant pull pin release

A double-retention redundant pull pin release system is disclosed. The system responds to a single pull during an intentional release operation. A spiral-threaded main pin is seated in a mating bore in a housing, which main pin has a flange fastened thereon at the part of the main pin which is exterior to the housing. Accidental release tends to rotate the main pin. A secondary pin passes through a slightly oversized opening in the flange and is seated in a second bore in the housing. The pins counteract against one another to prevent accidental release. A frictional lock is shared between the main and secondary pins to enhance further locking of the system. The secondary pin, in response to a first pull, is fully retracted from its bore and flange hole. Thereafter the pull causes the main pin to rotate free of the housing to release, for example, a parachute mechanism.

Killgrove, Thomas O.↗

Effect of Orion Post-Touchdown Parachute Release Time on Vehicle Rollover

The effects that the Orion parachutes have on the vehicle response once the vehicle lands on the ground are examined in this report. A concern with the Orion landing is that structural accelerations will cause vehicle and/or crew injuries or that the vehicle may roll over. The parachute effects are thought to have the potential of pulling the vehicle over during conditions such as higher winds or in some cases stabilizing the vehicle by preventing its motions after touchdown. A collection of representative landing conditions is used to assess the post-touchdown parachute release effect, and it was determined that, in general, there is no significant advantage or disadvantage to releasing the parachutes past the time when the vehicle touches ground. For landing conditions when there is a high horizontal wind, retaining the parachutes has a detrimental effect on vehicle rollover because the drag force on the parachutes pulls the vehicle over. Under this condition, some form of automated parachute release should be a requirement given that an attached parachute may cause the vehicle to roll over. An automated system would ensure that the release occur within 0.50 sec of touchdown (time when parachute regains tension), which is not enough time for a crew-operated manual release.

Lawrence, Charles↗

Kepler Data Release 3 Notes

This describes the collection of data and the processing done on it so when researchers around the world get the Kepler data sets (which are a set of pixels from the telescope of a particular target (star, galaxy or whatever) over a 3 month period) they can adjust their algorithms fro things that were done (like subtracting all of one particular wavelength for example). This is used to calibrate their own algorithms so that they know what it is they are starting with. It is posted so that whoever is accessing the publicly available data (not all of it is made public) can understand it .. (most of the Kepler data is under restriction for 1 - 4 years and is not available, but the handbook is for everyone (public and restricted) The Data Analysis Working Group have released long and short cadence materials, including FFls and Dropped Targets for the Public. The Kepler Science Office considers Data Release 3 to provide "browse quality" data. These notes have been prepared to give Kepler users of the Multimission Archive at STScl (MAST) a summary of how the data were collected and prepared, and how well the data processing pipeline is functioning on flight data. They will be updated for each release of data to the public archive and placed on MAST along with other Kepler documentation, at http:// archive.stsci.edu/kepler/documents.html .Data release 3 is meant to give users the opportunity to examine the data for possibly interesting science and to involve the users in improving the pipeline for future data releases. To perform the latter service, users are encouraged to notice and document artifacts, either in the raw or processed data, and report them to the Science Office.

Cleve, Jeffrey E.↗

Kepler Data Release 4 Notes

The Data Analysis Working Group have released long and short cadence materials, including FFIs and Dropped Targets for the Public. The Kepler Science Office considers Data Release 4 to provide "browse quality" data. These notes have been prepared to give Kepler users of the Multimission Archive at STScl (MAST) a summary of how the data were collected and prepared, and how well the data processing pipeline is functioning on flight data. They will be updated for each release of data to the public archive and placed on MAST along with other Kepler documentation, at http://archive.stsci.edu/kepler/documents.html. Data release 3 is meant to give users the opportunity to examine the data for possibly interesting science and to involve the users in improving the pipeline for future data releases. To perform the latter service, users are encouraged to notice and document artifacts, either in the raw or processed data, and report them to the Science Office.

Van Cleve, Jeffrey↗

Application of a Smart Parachute Release Algorithm to the CPAS Test Architecture

One of the primary test vehicles for the Capsule Parachute Assembly System (CPAS) is the Parachute Test Vehicle (PTV), a capsule shaped structure similar to the Orion design but truncated to fit in the cargo area of a C-17 aircraft. The PTV has a full Orion-like parachute compartment and similar aerodynamics; however, because of the single point attachment of the CPAS parachutes and the lack of Orion-like Reaction Control System (RCS), the PTV has the potential to reach significant body rates. High body rates at the time of the Drogue release may cause the PTV to flip while the parachutes deploy, which may result in the severing of the Pilot or Main risers. In order to prevent high rates at the time of Drogue release, a "smart release" algorithm was implemented in the PTV avionics system. This algorithm, which was developed for the Orion Flight system, triggers the Drogue parachute release when the body rates are near a minimum. This paper discusses the development and testing of the smart release algorithm; its implementation in the PTV avionics and the pretest simulation; and the results of its use on two CPAS tests.

Bledsoe, Kristin↗

NEQAIRv14.0 Release Notes: Nonequilibrium and Equilibrium Radiative Transport Spectra Program

NEQAIR v14.0 is the first parallelized version of NEQAIR. Starting from the last version of the code that went through the internal software release process at NASA Ames (NEQAIR 2008), there have been significant updates to the physics in the code and the computational efficiency. NEQAIR v14.0 supersedes NEQAIR v13.2, v13.1 and the suite of NEQAIR2009 versions. These updates have predominantly been performed by Brett Cruden and Aaron Brandis from ERC Inc at NASA Ames Research Center in 2013 and 2014. A new naming convention is being adopted with this current release. The current and future versions of the code will be named NEQAIR vY.X. The Y will refer to a major release increment. Minor revisions and update releases will involve incrementing X. This is to keep NEQAIR more in line with common software release practices. NEQAIR v14.0 is a standalone software tool for line-by-line spectral computation of radiative intensities and/or radiative heat flux, with one-dimensional transport of radiation. In order to accomplish this, NEQAIR v14.0, as in previous versions, requires the specification of distances (in cm), temperatures (in K) and number densities (in parts/cc) of constituent species along lines of sight. Therefore, it is assumed that flow quantities have been extracted from flow fields computed using other tools, such as CFD codes like DPLR or LAURA, and that lines of sight have been constructed and written out in the format required by NEQAIR v14.0. There are two principal modes for running NEQAIR v14.0. In the first mode NEQAIR v14.0 is used as a tool for creating synthetic spectra of any desired resolution (including convolution with a specified instrument/slit function). The first mode is typically exercised in simulating/interpreting spectroscopic measurements of different sources (e.g. shock tube data, plasma torches, etc.). In the second mode, NEQAIR v14.0 is used as a radiative heat flux prediction tool for flight projects. Correspondingly, NEQAIR has also been used to simulate the radiance measured on previous flight missions. This report summarizes the database updates, corrections that have been made to the code, changes to input files, parallelization, the current usage recommendations, including test cases, and an indication of the performance enhancements achieved.

Radiation Solver↗

The Gaia Catalogue Second Data Release and Its Implications to Optical Observations of Man-Made Earth Orbiting Objects

The Gaia catalogue second data release and its implications to optical observations of man-made Earth orbiting objects. Abstract and not the Final Paper is attached. The Gaia spacecraft was launched in December 2013 by the European Space Agency to produce a three-dimensional, dynamic map of objects within the Milky Way. Gaia's first year of data was released in September 2016. Common sources from the first data release have been combined with the Tycho-2 catalogue to provide a 5 parameter astrometric solution for approximately 2 million stars. The second Gaia data release is scheduled to come out in April 2018 and is expected to provide astrometry and photometry for more than 1 billion stars, a subset of which with a the full 6 parameter astrometric solution (adding radial velocity) and positional accuracy better than 0.002 arcsec (2 mas). In addition to precise astrometry, a unique opportunity exists with the Gaia catalogue in its production of accurate, broadband photometry using the Gaia G filter. In the past, clear filters have been used by various groups to maximize likelihood of detection of dim man-made objects but these data were very difficult to calibrate. With the second release of the Gaia catalogue, a ground based system utilizing the G band filter will have access to 1.5 billion all-sky calibration sources down to an accuracy of 0.02 magnitudes or better. In this talk, we will discuss the advantages and practicalities of implementing the Gaia filters and catalogue into data pipelines designed for optical observations of man-made objects.

Frith, James M.↗

A COMPREHENSIVE ANALYSIS OF CHLORINE TRANSPORT AND FATE FOLLOWING A LARGE ENVIRONMENTAL RELEASE

A train derailment occurred in Graniteville, South Carolina during the early morning of January 6, 2005, and resulted in the release of a large amount of cryogenic pressurized liquid chlorine to the environment in a short time period. A comprehensive evaluation of the transport and fate of the released chlorine was performed, accounting for dilution, diffusion, transport and deposition into the local environment. This involved the characterization of a three-phased chlorine release, a detailed determination of local atmospheric mechanisms acting on the released chlorine, the establishment of atmospheric-hydrological physical exchange mechanisms, and aquatic dilution and mixing. This presentation will provide an overview of the models used in determining the total air-to-water mass transfer estimated to have occurred as a result of the roughly 60 tons of chlorine released into the atmosphere from the train derailment. The assumptions used in the modeling effort will be addressed, along with a comparison with available observational data to validate the model results. Overall, model-estimated chlorine concentrations in the airborne plume compare well with human and animal exposure data collected in the days after the derailment.

54 ENVIRONMENTAL SCIENCES↗

Inhibited Release of Mobile Contaminants from Hanford Tank Residual Waste

Investigations of contaminant release from Hanford Site tank residual waste have indicated that in some cases certain contaminants of interest (Tc and Cr) exhibit inhibited release. The percentage of Tc that dissolved from residual waste from tanks 241-C-103, 241-C-106, 241-C-202, and 241-C-203 ranged from approximately 6% to 10%. The percent leachable Cr from residual waste from tanks C-103, C 202, and C-203 ranged from approximately 1.1% to 44%. Solid phase characterization results indicate that the recalcitrant forms of these contaminants are associated with iron oxides. X-ray absorption near edge structure analysis of Tc and Cr in residual waste indicates that these contaminants occur in Fe oxide particles as their lower, less soluble oxidation states [Tc(IV) and Cr(III)]. The form of these contaminants is likely as oxides or hydroxides incorporated within the structure of the Fe oxide. Leaching behavior of U from tank residual waste was studied using deionized water, and CaCO3 and Ca(OH)2 saturated solutions as leachants. The release behavior of U from tank residual waste is complex. Initial U concentrations in water and CaCO3 leachants are high due to residual amounts of the highly soluble U mineral cejkaite. As leaching and dilution occur NaUO2PO4 {center_dot} xH2O, Na2U2O7(am) and schoepite (or a similar phase) become the solubility controlling phases for U. In the case of the Ca(OH)2 leachant, U release from tank residual waste is dramatically reduced. Thermodynamic modeling indicates that the solubility of CaUO4(c) controls release of U from residual waste in the Ca(OH)2 leachants. It is assumed the solubility controlling phase is actually a hydrated version of CaUO4 with a variable water content ranging from CaUO4 to CaUO4 {center_dot} (H2O). The critically reviewed value for CaUO4(c) (log KSP0 = 15.94) produced good agreement with our experimental data for the Ca(OH)2 leachates.

12 MANAGEMENT OF RADIOACTIVE AND NON-RADIOACTIVE W↗

Method of forming through substrate vias (TSVs) and singulating and releasing die having the TSVs from a mechanical support substrate

Accessing a workpiece object in semiconductor processing is disclosed. The workpiece object includes a mechanical support substrate, a release layer over the mechanical support substrate, and an integrated circuit substrate coupled over the release layer. The integrated circuit substrate includes a device layer having semiconductor devices. The method also includes etching through-substrate via (TSV) openings through the integrated circuit substrate that have buried ends at or within the release layer including using the release layer as an etch stop. TSVs are formed by introducing one or more conductive materials into the TSV openings. A die singulation trench is etched at least substantially through the integrated circuit substrate around a perimeter of an integrated circuit die. The integrated circuit die is at least substantially released from the mechanical support substrate.

36 MATERIALS SCIENCE↗

Upflow bioreactor with septum and pressure release mechanism

An upflow bioreactor includes a vessel having an inlet and an outlet configured for upflow operation. A septum is positioned within the vessel and defines a lower chamber and an upper chamber. The septum includes an aperture that provides fluid communication between the upper chamber and lower chamber. The bioreactor also includes means for releasing pressure buildup in the lower chamber. In one configuration, the septum includes a releasable portion having an open position and a closed position. The releasable portion is configured to move to the open position in response to pressure buildup in the lower chamber. In the open position fluid communication between the lower chamber and the upper chamber is increased. Alternatively the lower chamber can include a pressure release line that is selectively actuated by pressure buildup. The pressure release mechanism can prevent the bioreactor from plugging and/or prevent catastrophic damage to the bioreactor caused by high pressures.

47 OTHER INSTRUMENTATION↗

Determination of the Quantity of I-135 Released from the AGR Experiment Series

A series of three Advanced Gas Reactor (AGR) experiments have been conducted in the Advanced Test Reactor (ATR) at Idaho National Laboratory (INL). From 2006 through 2014, these experiments supported the development and qualification of the new U.S. tri structural isotropic (TRISO) particle fuel for Very High Temperature Reactors (VHTR). Each AGR experiment consisted of multiple fueled capsules, each plumbed for independent temperature control using a mix of helium and neon gases. The gas leaving a capsule was routed to individual Fission Product Monitor (FPM) detectors. For intact fuel particles, the TRISO particle coatings provide a substantial barrier to fission product release. However, particles with failed coatings, whether because of a minute percentage of initially defective particles, those which fail during irradiation, or those designed to fail (DTF) particles, can release fission products to the flowing gas stream. Because reactive fission product elements like iodine and cesium quickly deposit on cooler capsule components and piping structures as the effluent gas leaves the reactor core, only the noble fission gas isotopes of Kr and Xe tend to reach FPM detectors. The FPM system utilizes High Purity Germanium (HPGe) detectors coupled with a thallium activated sodium iodide NaI(Tl) scintillator. The germanium detector provides individual isotopic information, while the NaI(Tl) scintillator is used as a gross count rate meter. During irradiation, the 135mXe concentration reaching the FPM detectors is from both direct fission and by decay of the accumulated 135I. About ~2.5 hours after irradiation (ten 15.3 minute 135mXe half lives) the directly produced 135mXe has decayed and only the longer lived 135I remains as a source. Decay systematics dictate that 135mXe will be in secular equilibrium with its 135I parent, such that it’s production rate very nearly equals the decay rate of the parent, and its concentration in the flowing gas stream will appear to decay with the parent half life. This equilibrium condition enables the determination of the amount of 135I released from the fuel particles by measurement of the 135mXe at the FPM following reactor shutdown. In this paper, the 135I released will be reported and compared to similar releases for noble gases as well as the unexpected finding of 131I deposition from intentional impure gas injection into capsule 11 of experiment AGR 3/4.

AGR↗

Nitride-based controlled-release fertilizers and process for making same

A controlled-release solid nitride fertilizer from fly ash and a method for making are described. The fertilizer includes a nitrogen source including at least one solid nitride combined with at least one precipitation-inhibiting agent and with at least one moisture-retention agent, all compressed together to form a porous release structure that in contact with water releases ammonium ions as a nitrogen nutrient at a substantially uniform release rate over a selected release period and thereby maximizes nitrogen-use efficiency by plants.

Amonette, James E.↗

Modeling Pre-Spark Heat Release and Low Temperature Chemistry of Iso-Octane in a Boosted Spark-Ignition Engine

Recent trends among automotive manufacturers towards downsized, boosted engines make it imperative to understand specific fuel chemistry interactions encountered in this new operating regime. At these elevated pressure conditions a phenomenon called pre-spark heat release (PSHR) has recently been discovered, characterized by kinetically controlled heat release before spark, leading to changes in end-gas thermodynamic state and composition. These reactions typically occur in the end-gas during normal operation, but are obscured by the deflagration heat release, and therefore cannot be easily studied. A 2-zone spark-ignition engine model was utilized to determine whether chemical kinetic mechanisms predict this phenomenon, and whether they accurately capture end-gas thermodynamic history. Experimental engine data at a range of boosted operating conditions demonstrating PSHR were compared with simulations using mechanisms representing the latest developments in gasoline kinetic modeling. The results demonstrated significant discrepancies between mechanisms, and between experimental and simulated results in terms of low-temperature heat release magnitude and end-gas thermodynamic state. That none of the un-tuned mechanisms matched the experimental results highlights shortcomings in low-temperature reaction pathways, and indicate the necessity of simultaneously matching first-stage ignition delay and heat release magnitude, in addition to second-stage ignition delay, in order to accurately predict end-gas thermodynamics and knock.

Delvescovo, Dan↗