Localizing intracavitary brachytherapy applicators from cone-beam CT x-ray projections via a novel iterative forward projection matching algorithm

Purpose: To present a novel method for reconstructing the 3D pose (position and orientation) of radio-opaque applicators of known but arbitrary shape from a small set of 2D x-ray projections in support of intraoperative brachytherapy planning. Methods: The generalized iterative forward projection matching (gIFPM) algorithm finds the six degree-of-freedom pose of an arbitrary rigid object by minimizing the sum-of-squared-intensity differences (SSQD) between the computed and experimentally acquired autosegmented projection of the objects. Starting with an initial estimate of the object's pose, gIFPM iteratively refines the pose parameters (3D position and three Euler angles) until the SSQD converges. The object, here specialized to a Fletcher-Weeks intracavitary brachytherapy (ICB) applicator, is represented by a fine mesh of discrete points derived from complex combinatorial geometric models of the actual applicators. Three pairs of computed and measured projection images with known imaging geometry are used. Projection images of an intrauterine tandem and colpostats were acquired from an ACUITY cone-beam CT digital simulator. An image postprocessing step was performed to create blurred binary applicators only images. To quantify gIFPM accuracy, the reconstructed 3D pose of the applicator model was forward projected and overlaid with the measured images and empirically calculated the nearest-neighbor applicator positional difference for each image pair. Results: In the numerical simulations, the tandem and colpostats positions (x,y,z) and orientations ({alpha},{beta},{gamma}) were estimated with accuracies of 0.6 mm and 2 deg., respectively. For experimentally acquired images of actual applicators, the residual 2D registration error was less than 1.8 mm for each image pair, corresponding to about 1 mm positioning accuracy at isocenter, with a total computation time of less than 1.5 min on a 1 GHz processor. Conclusions: This work describes a novel, accurate, fast, and completely automatic method to localize radio-opaque applicators of arbitrary shape from measured 2D x-ray projections. The results demonstrate {approx}1 mm accuracy while compared against the measured applicator projections. No lateral film is needed. By localizing the applicator internal structure as well as radioactive sources, the effect of intra-applicator and interapplicator attenuation can be included in the resultant dose calculations. Further validation tests using clinically acquired tandem and colpostats images will be performed for the accurate and robust applicator/sources localization in ICB patients.

60 APPLIED LIFE SCIENCES↗

Cobalt-60 tomotherapy: Clinical treatment planning and phantom dose delivery studies

Purpose: Investigations have shown that a Cobalt-60 (Co-60) radioactive source has the potential to play a role in intensity modulated radiation therapy (IMRT). In this paper, Co-60 tomotherapy's conformal dose delivery potential is evaluated by delivering conformal dose plans on a cylindrical homogeneous phantom containing clinical structures similar to those found in a typical head and neck (H and N) cancer. Also, the clinical potential of Co-60 tomotherapy is investigated by generating 2D clinical treatment plans for H and N and prostate anatomical regions. These plans are compared with the 6 MV based treatment plans for modalities such as linear accelerator-based tomotherapy and broad beam IMRT, and 15 MV based 3D conformal radiation therapy (3DCRT).Methods: For experimental validation studies, clinical and nonclinical conformal dose patterns were delivered on circular, homogeneous phantoms containing GafChromic film. For clinical planning study, dose calculations were performed with the EGSnrc Monte Carlo program, where a Theratronics 780C Co-60 unit and a 6 MV linear accelerator were modeled with a MIMiC binary multileaf collimator. An inhouse inverse treatment planning system was used to optimize tomotherapy plans using the same optimization parameters for both Co-60 and 6 MV beams. The IMRT and 3DCRT plans for the clinical cases were generated entirely in the Eclipse treatment planning system based on inhouse IMRT and 3DCRT site specific protocols.Results: The doses delivered to the homogeneous phantoms agreed with the calculations, indicating that it is possible to deliver highly conformal doses with the Co-60 unit. The dose distributions for Co-60 tomotherapy clinical plans for both clinical cases were similar to those obtained with 6 MV based tomotherapy and IMRT, and much more conformal compared to 3DCRT plans. The dose area histograms showed that the Co-60 plans achieve the dose objectives for the targets and organs at risk.Conclusions: These results confirm that Co-60 tomotherapy is capable of providing state-of-the-art conformal dose delivery and could be used for the treatment of targets in both small and larger separation anatomical regions.

61 RADIATION PROTECTION AND DOSIMETRY↗

SU-E-J-93: Parametrisation of Dose to the Mucosa of the Anterior Rectal Wall in Transrectal Ultrasound Guided High-Dose-Rate Brachytherapy of the Prostate

Purpose: In high-dose-rate (HDR) brachytherapy of the prostate, radiation is delivered from a number of radioactive sources which are inserted via catheter into the target volume. The rectal mucosa also receives dose during the treatment, which may lead to late toxicity effects. To allow possible links between rectal dose and toxicity to be investigated, suitable methods of parametrising the rectal dose are needed. Methods: During treatment of a series of 95 patients, anatomy and catheter locations were monitored by transrectal ultrasound, and target volume positions were contoured on the ultrasound scan by the therapist. The anterior rectal mucosal wall was identified by contouring the transrectal ultrasound balloon within the ultrasound scan. Source positions and dwell times, along with the dose delivered to the patient were computed using the Oncentra Prostate treatment planning system (TPS). Data for the series of patients were exported from the TPS in Dicom format, and a series of parametrisation methods were developed in a Matlab environment to assess the rectal dose. Results: Contours of the anterior rectal mucosa were voxelised within Matlab to allow the dose to the rectal mucosa to be analysed directly from the 3D dose grid. Dose parametrisations based on dose-surface (DSH) and dose-line (DLH) histograms were obtained. Both lateral and longitudinal extents of the mucosal dose were parametrised using dose-line histograms in the relevant directions. Conclusion: We have developed a series of dose parametrisations for quantifying the dose to the rectal mucosa during HDR prostate brachytherapy which are suitable for future studies investigating potential associations between mucosal dose and late toxicity effects. The geometry of the transrectal probe standardises the rectal anatomy, making this treatment technique particularly suited to studies of this nature.

60 APPLIED LIFE SCIENCES↗

SU-E-T-338: Ultrastable PRNA 3WJ Nanoparticles as Potential I-125 and C-131 Carriers for Targeted Radiation Therapy

Purpose: To study the feasibility of using the pRNA 3WJ nanoparticles to carry I-125 or Cs-131 to target and treat cancer. As the first step, we investigated the stabilities of pRNA 3WJ nanoparticles that are essential for cancer targeting and treatment in this study. Methods: The thermodynamic stability of assembled RNA 3WJ nanoparticles was studied using the TGGE system. The nanoparticles were irradiated with I-125 or Cs-131 radioactive sources that were immersed in the RNA nanoparticle/DNA structure sample liquid contained in a small vial. The irradiation of the RNA samples was performed for different time periods and doses. The purpose was to distinguish the effects of radiation on DNA and RNA structures. Unradiated samples were used as control. Results: RNA nanoparticles were formed by mixing three pieces of oligos, 3WJa, 3WJb, and 3WJc at 1:1:1 molar ratio. Figure 4 demonstrates that 2′-F modified 3WJ nanoparticles remained stable at temperatures as high as 66.8 ± 2°C, and exhibited melting temperatures of 71 ± 2°C. The radiation stability test was performed with I- 125 and Cs-131 irradiation. Several DNA structures including plasmids were included as control. The first test introduced I-125 and a low dose of 1 Gy to both RNA and DNA samples, but no change was observed. When the dose was increased to 30 Gy, DNA was damaged while RNA remained unchanged. Three tests were also conducted with Cs-131 with 7 Gy, 21 Gy, 30 Gy, and 89 Gy, and the results were similar to those with I-125. Conclusion: pRNA 3WJ nanoparticles are able to form efficiently by onepot self-assembly. They remained stable at high temperatures and high therapeutic doses over a long time. These unique features suggest that RNA 3WJ nanoparticles have the potential to be used for targeted radiation therapy for cancer treatment.

60 APPLIED LIFE SCIENCES↗

Poster — Thur Eve — 40: Automated Quality Assurance for Remote-Afterloading High Dose Rate Brachytherapy

High dose rate (HDR) remote afterloading brachytherapy involves sending a small, high-activity radioactive source attached to a cable to different positions within a hollow applicator implanted in the patient. It is critical that the source position within the applicator and the dwell time of the source are accurate. Daily quality assurance (QA) tests of the positional and dwell time accuracy are essential to ensure that the accuracy of the remote afterloader is not compromised prior to patient treatment. Our centre has developed an automated, video-based QA system for HDR brachytherapy that is dramatically superior to existing diode or film QA solutions in terms of cost, objectivity, positional accuracy, with additional functionalities such as being able to determine source dwell time and transit time of the source. In our system, a video is taken of the brachytherapy source as it is sent out through a position check ruler, with the source visible through a clear window. Using a proprietary image analysis algorithm, the source position is determined with respect to time as it moves to different positions along the check ruler. The total material cost of the video-based system was under $20, consisting of a commercial webcam and adjustable stand. The accuracy of the position measurement is ±0.2 mm, and the time resolution is 30 msec. Additionally, our system is capable of robustly verifying the source transit time and velocity (a test required by the AAPM and CPQR recommendations), which is currently difficult to perform accurately.

07 ISOTOPE AND RADIATION SOURCES↗

MO-B-BRC-03: CT-Based Prostate HDR

Brachytherapy has proven to be an effective treatment option for prostate cancer. Initially, prostate brachytherapy was delivered through permanently implanted low dose rate (LDR) radioactive sources; however, high dose rate (HDR) temporary brachytherapy for prostate cancer is gaining popularity. Needle insertion during prostate brachytherapy is most commonly performed under ultrasound (U/S) guidance; however, treatment planning may be performed utilizing several imaging modalities either in an intra- or post-operative setting. During intra-operative prostate HDR, the needles are imaged during implantation, and planning may be performed in real time. At present, the most common imaging modality utilized for intra-operative prostate HDR is U/S. Alternatively, in the post-operative setting, following needle implantation, patients may be simulated with computed tomography (CT) or magnetic resonance imaging (MRI). Each imaging modality and workflow provides its share of benefits and limitations. Prostate HDR has been adopted in a number of cancer centers across the nation. In this educational session, we will explore the role of U/S, CT, and MRI in HDR prostate brachytherapy. Example workflows and operational details will be shared, and we will discuss how to establish a prostate HDR program in a clinical setting. Learning Objectives: Review prostate HDR techniques based on the imaging modality Discuss the challenges and pitfalls introduced by the three imagebased options for prostate HDR brachytherapy Review the QA process and learn about the development of clinical workflows for these imaging options at different institutions.

60 APPLIED LIFE SCIENCES↗

MO-B-BRC-04: MRI-Based Prostate HDR

Brachytherapy has proven to be an effective treatment option for prostate cancer. Initially, prostate brachytherapy was delivered through permanently implanted low dose rate (LDR) radioactive sources; however, high dose rate (HDR) temporary brachytherapy for prostate cancer is gaining popularity. Needle insertion during prostate brachytherapy is most commonly performed under ultrasound (U/S) guidance; however, treatment planning may be performed utilizing several imaging modalities either in an intra- or post-operative setting. During intra-operative prostate HDR, the needles are imaged during implantation, and planning may be performed in real time. At present, the most common imaging modality utilized for intra-operative prostate HDR is U/S. Alternatively, in the post-operative setting, following needle implantation, patients may be simulated with computed tomography (CT) or magnetic resonance imaging (MRI). Each imaging modality and workflow provides its share of benefits and limitations. Prostate HDR has been adopted in a number of cancer centers across the nation. In this educational session, we will explore the role of U/S, CT, and MRI in HDR prostate brachytherapy. Example workflows and operational details will be shared, and we will discuss how to establish a prostate HDR program in a clinical setting. Learning Objectives: Review prostate HDR techniques based on the imaging modality Discuss the challenges and pitfalls introduced by the three imagebased options for prostate HDR brachytherapy Review the QA process and learn about the development of clinical workflows for these imaging options at different institutions.

60 APPLIED LIFE SCIENCES↗

MO-B-BRC-00: Prostate HDR Treatment Planning - Considering Different Imaging Modalities

Brachytherapy has proven to be an effective treatment option for prostate cancer. Initially, prostate brachytherapy was delivered through permanently implanted low dose rate (LDR) radioactive sources; however, high dose rate (HDR) temporary brachytherapy for prostate cancer is gaining popularity. Needle insertion during prostate brachytherapy is most commonly performed under ultrasound (U/S) guidance; however, treatment planning may be performed utilizing several imaging modalities either in an intra- or post-operative setting. During intra-operative prostate HDR, the needles are imaged during implantation, and planning may be performed in real time. At present, the most common imaging modality utilized for intra-operative prostate HDR is U/S. Alternatively, in the post-operative setting, following needle implantation, patients may be simulated with computed tomography (CT) or magnetic resonance imaging (MRI). Each imaging modality and workflow provides its share of benefits and limitations. Prostate HDR has been adopted in a number of cancer centers across the nation. In this educational session, we will explore the role of U/S, CT, and MRI in HDR prostate brachytherapy. Example workflows and operational details will be shared, and we will discuss how to establish a prostate HDR program in a clinical setting. Learning Objectives: Review prostate HDR techniques based on the imaging modality Discuss the challenges and pitfalls introduced by the three imagebased options for prostate HDR brachytherapy Review the QA process and learn about the development of clinical workflows for these imaging options at different institutions.

60 APPLIED LIFE SCIENCES↗

MO-B-BRC-01: Introduction [Brachytherapy ]

Brachytherapy has proven to be an effective treatment option for prostate cancer. Initially, prostate brachytherapy was delivered through permanently implanted low dose rate (LDR) radioactive sources; however, high dose rate (HDR) temporary brachytherapy for prostate cancer is gaining popularity. Needle insertion during prostate brachytherapy is most commonly performed under ultrasound (U/S) guidance; however, treatment planning may be performed utilizing several imaging modalities either in an intra- or post-operative setting. During intra-operative prostate HDR, the needles are imaged during implantation, and planning may be performed in real time. At present, the most common imaging modality utilized for intra-operative prostate HDR is U/S. Alternatively, in the post-operative setting, following needle implantation, patients may be simulated with computed tomography (CT) or magnetic resonance imaging (MRI). Each imaging modality and workflow provides its share of benefits and limitations. Prostate HDR has been adopted in a number of cancer centers across the nation. In this educational session, we will explore the role of U/S, CT, and MRI in HDR prostate brachytherapy. Example workflows and operational details will be shared, and we will discuss how to establish a prostate HDR program in a clinical setting. Learning Objectives: Review prostate HDR techniques based on the imaging modality Discuss the challenges and pitfalls introduced by the three imagebased options for prostate HDR brachytherapy Review the QA process and learn about the development of clinical workflows for these imaging options at different institutions.

60 APPLIED LIFE SCIENCES↗

MO-B-BRC-02: Ultrasound Based Prostate HDR

Brachytherapy has proven to be an effective treatment option for prostate cancer. Initially, prostate brachytherapy was delivered through permanently implanted low dose rate (LDR) radioactive sources; however, high dose rate (HDR) temporary brachytherapy for prostate cancer is gaining popularity. Needle insertion during prostate brachytherapy is most commonly performed under ultrasound (U/S) guidance; however, treatment planning may be performed utilizing several imaging modalities either in an intra- or post-operative setting. During intra-operative prostate HDR, the needles are imaged during implantation, and planning may be performed in real time. At present, the most common imaging modality utilized for intra-operative prostate HDR is U/S. Alternatively, in the post-operative setting, following needle implantation, patients may be simulated with computed tomography (CT) or magnetic resonance imaging (MRI). Each imaging modality and workflow provides its share of benefits and limitations. Prostate HDR has been adopted in a number of cancer centers across the nation. In this educational session, we will explore the role of U/S, CT, and MRI in HDR prostate brachytherapy. Example workflows and operational details will be shared, and we will discuss how to establish a prostate HDR program in a clinical setting. Learning Objectives: Review prostate HDR techniques based on the imaging modality Discuss the challenges and pitfalls introduced by the three imagebased options for prostate HDR brachytherapy Review the QA process and learn about the development of clinical workflows for these imaging options at different institutions.

60 APPLIED LIFE SCIENCES↗

Sci-Sat AM: Radiation Dosimetry and Practical Therapy Solutions - 11: Commissioning of a system for the measurement of electron stopping powers

Purpose: To develop the techniques required to experimentally determine electron stopping powers for application in primary standards and dosimetry protocols. Method and Materials: A large-volume HPGe detector system (>80% efficiency) was commissioned for the measurement of high energy (5–35 MeV) electron beams. As a proof of principle the system was used with a Y-90/Sr-90 radioactive source. Thin plates of absorbing material (< 0.1 gcm-2) were then placed between the source and detector and the emerging electron spectrum was acquired. The full experimental geometry was modelled using the EGSnrc package to validate the detector design, optimize the experimental setup and compare measured and calculated spectra. Results: The biggest challenge using a beta source was to identify a robust spectral parameter to determine for each measurement. An end-point-fitting routine was used to determine the maximum energy, Emax, of the beta spectrum for each absorber thickness t. The parameter dEmax/dt is related to the electron stopping power and the same routine was applied to both measured and simulated spectra. Although the standard uncertainty in dEmax/dt was of the order of 5 %, by taking the ratio of measured and Monte Carlo values for dEmax/dt the uncertainty of the fitting routine was eliminated and the uncertainty was reduced to less than 2 %. The agreement between measurement and simulation was within this uncertainty estimate. Conclusion: The investigation confirmed the experimental approach and demonstrated that EGSnrc could accurately determine correction factors that will be required for the final measurement setup in a linac beam.

61 RADIATION PROTECTION AND DOSIMETRY↗

First operation of undoped CsI directly coupled with SiPMs at 77 K

Abstract The light yield of a small undoped cesium iodide (CsI) crystal directly coupled with two silicon photomultipliers (SiPMs) at about 77 Kelvin was measured to be $$43.0 \pm 1.1$$ 43.0 ± 1.1 photoelectrons (PE) per keV electron-equivalent (keV $$_\text {ee}$$ ee ) using X and $$\gamma $$ γ -ray peaks from an $$^{241}$$ 241 Am radioactive source from 18 to 60 keV. The high light yield together with some other technical advantages illustrate the great potential of this novel combination for neutrino and low-mass dark matter detection, particularly at accelerator-based neutrino sources, where random background can be highly suppressed by requiring coincident triggers between SiPMs and beam pulse timing signals. Some potential drawbacks of using cryogenic SiPMs instead of photomultiplier tubes (PMTs) were identified, such as worse energy resolution and optical cross-talks between SiPMs. Their influence to rare-event detection was discussed and possible solutions were provided.

71 CLASSICAL AND QUANTUM MECHANICS, GENERAL PHYSIC↗

Overview of Accelerator Applications for Security and Defense

Particle accelerators play a key role in a broad set of defense and security applications including war-fighter and asset protection, cargo inspection, nonproliferation, materials characterization and stockpile stewardship. Accelerators can replace the high activity radioactive sources that pose a security threat for developing a radiological dispersal device and be used to produce isotopes for medical, industrial, and re-search purposes. Lastly, we present an overview of current and emerging accelerator technologies relevant to addressing the needs of defense and security.

43 PARTICLE ACCELERATORS↗

Radsource Mr: Mixed Reality Planning Tool For Radioactive Recovery

The RadSource MR system leverages Meta Quest 3's advanced mixed reality capabilities to create a comprehensive spatial planning platform for end-of-life sealed radioactive source recovery operations. The application utilizes the Quest 3's high-resolution passthrough cameras and spatial mapping algorithms to generate accurate 3D environmental models. Core technical components include: (1) Real-time spatial measurement algorithms calculating distances, angles, slopes, and surface areas with sub-centimeter accuracy; (2) Virtual object placement system allowing users to position digital representations of recovery equipment (trailers, containment vessels, protective barriers) within the real environment; (3) Voice recording and annotation system for hands-free documentation in protective equipment; (4) 3D mesh capture and storage capabilities for post-operation analysis and regulatory documentation. (5) Procedure documentation is available for viewing in Mixed Reality, providing an innovative and convenient way to access the information during pre-visit and inspection activities. (6) Support for screen capture for the view for real world and virtual objects together to use it later for planning. The system integrates computer vision techniques for environmental understanding, spatial mathematics for precise measurements, and human-computer interaction principles optimized for hazardous environment operations. Data persistence allows teams to save and share planning sessions across multiple stakeholders while maintaining operational security requirements.

Khadka, Rajiv [Idaho National Laboratory (INL), Id↗

Sensitivity analysis of small modular reactor mPower with ATHLET

Small modular reactor (SMR) possesses the characteristics of less radioactive source term, simpler structure, modular design and features like passive safety as well as low risk of proliferation. Developed and designed by Babcock and Wilcox, the mPower reactor is one of pronouncing small modular reactors that adopts the integrated design of the pressurized water reactor, steam generator and a built-in internal control rod drive mechanism. In this paper, the code ATHLET (Analysis of fossil-hydraulics of Leaks and Transients) is used to model the mPower reactor. At the same time, the sensitivity analysis of the core structure and geometric parameters of the pipeline loop, as well as the steady-state simulation and post-exothermic simulation are carried out depending on the given scenarios. In addition, the sensitivity analysis of pressure, temperature and mass flow in the secondary loop is performed. The results of this study will mitigate some of the frequent misunderstanding in the field and will help to better understand the design of SMR and provide basic research data for further research. However, there are limitations in the current research. Considering that the mPower is still in the conceptual design, the established model is only based on the limited public data while detailed parameters are still in myth, which leads to certain level of uncertainties in the calculation. Besides, the research is mainly on the influence of sensitivity analysis under steady state conditions. (authors)

21 SPECIFIC NUCLEAR REACTORS AND ASSOCIATED PLANTS↗

Transformational challenge reactor design characteristics

The Transformational Challenge Reactor (TCR) program was conceived with the goal to reduce costs and time frames associated with advanced reactor deployment by leveraging developments in advanced manufacturing, advanced materials, data science, and rapid prototyping and testing. The final deliverable of the TCR program was to be an operational test of a novel reactor design. The TCR core design incorporates a dense tri-structural-isotropic/SiC fuel form and volumetrically efficient yttrium hydride moderator, both of which were manufactured and characterized under the TCR program. The TCR is a 3 MW{sub th} He-cooled experimental nuclear reactor designed to reach a total integrated burnup of less than 24 effective full-power hours to keep the radioactive source term to a very low level. TCR design process revealed a positive moderator coefficient; however, the negative doppler coefficients for the fuel and thermal expansion of fuel, moderator, and core support plate yield an overall negative reactivity coefficient. Calculated fuel element temperatures and stresses are well within safety margins. The maximum hypothetical accident (i.e., de-pressurized loss of forced cooling) yields only a modest increase in reactor temperatures that are all within safety margins. This paper summarizes the high-level TCR design characteristics, which were derived from neutronics, thermohydraulics, thermomechanics, and safety analyses.

21 SPECIFIC NUCLEAR REACTORS AND ASSOCIATED PLANTS↗

Atmospheric effects on the laser-driven avalanche-based remote detection of radiation

Here, the effect of realistic atmospheric conditions on mid-IR (λ = 3.9 µm) and long-wave-IR (λ = 10 µm) laser-induced avalanche breakdown for the remote detection of radioactive material is examined experimentally and with propagation simulations. Our short-range in-lab mid-IR laser experiments show a correlation between increasing turbulence level and a reduced number of breakdown sites associated with a reduction in the portion of the focal volume above the breakdown threshold. Simulations of propagation through turbulence are in excellent agreement with these measurements and provide code validation. We then simulate propagation through realistic atmospheric turbulence over a long range (0.1–1 km) in the long-wave-IR regime (λ = 10 µm). The avalanche threshold focal volume is found to be robust even in the presence of strong turbulence, only dropping by ~50% over a propagation length of ~0.6 km. We also experimentally assess the impact of aerosols on avalanche-based detection, finding that, while background counts increase, a useful signal is extractable even at aerosol concentrations 10 5 times greater than what is typically observed in atmospheric conditions. Our results show promise for the long-range detection of radioactive sources under realistic atmospheric conditions.

54 ENVIRONMENTAL SCIENCES↗

Measurement of ultralow radiation-induced charge densities using picosecond mid-IR laser-induced breakdown

We demonstrate that avalanche ionization breakdown of air with picosecond mid-infrared (mid-IR) laser pulses is an exceptionally sensitive and quantitative probe of extremely low concentrations of charged species. By exponentially increasing the electron density in the vicinity of a single seed atom or molecule to detectable levels, mid-IR electron avalanche is an analogue of single photon detection in photomultiplier tubes and can be useful in a range of applications. We apply the technique to meter-scale standoff detection of a radioactive source, sensitive to extremely low concentrations of radiation-induced negative ions down to ~ 10 3 cm - 3 , limited only by background. By imaging the location of spatially isolated avalanche breakdown sites, we directly measure these low densities and benchmark the performance of standoff detection diagnostics. We discuss implementation of this radiation detection scheme at ranges of 10–100 m and adapting the avalanche probe to detection of other low-density plasmas.

71 CLASSICAL AND QUANTUM MECHANICS, GENERAL PHYSIC↗