Engineering Papers⌕ Search

SEARCH · Engineering Papers

Results for “RADIATION FALL OUT”

Search indexed NASA NTRS and DOE OSTI research on propulsion, heat transfer, battery materials and energy systems. Follow report and document links to the original sources.

Quote a phrase for an exact phrase match. Source license links do not imply unrestricted reuse.

At least 433 records · Page 24

Reaction-Induced Fracturing of Porous Carbonate Rocks during Volume-Increasing Replacement by Witherite

Volume-increasing replacement reactions can lead either to fracturing of the parent phase or to the formation of cohesive layers that passivate further reaction, but the factors that drive one outcome or the other are not understood. In this experimental study, we investigated the volume-increasing replacement of carbonate rocks (consisting of CaCO 3 and CaMg(CO 3 ) 2 ) of different porosity by witherite (BaCO 3 ). Samples were characterized using scanning electron microscopy, Raman spectroscopy, small-angle neutron/X-ray scattering, X-ray tomography, and scanning transmission electron microscopy. We observed the formation of a witherite reaction layer and witherite formation within pores and along grain boundaries. Despite this being a volume-increasing replacement reaction, newly formed witherite was porous, potentially allowing further replacement. Filled fractures were observed in the low-porosity carbonates, whereas witherite formed within pores in high-porosity carbonates. We conclude that fracturing of the parent phase versus passivation is contingent on the initial microstructure of the parent with an optimal degree of porosity required for fracturing.

Calcite↗

Emergent Relationships Among Sea Ice, Longwave Radiation, and the Beaufort High Circulation Exposed Through Parameter Uncertainty Analysis

Using a perturbed parameter ensemble of a coupled climate model, emerging relationships are identified between sea ice area, net surface longwave radiation, and the atmospheric circulation over the Beaufort gyre. There is a strong positive correlation between sea ice area and the net longwave radiation over the ocean-ice surface during the melting season and a negative correlation during the freezing season. The mechanisms responsible for the longwave radiation balance at the surface are mainly driven by sea ice variations in the freezing season and by clouds in the melting season. A strong positive (negative) correlation is also found between the fall (summer) total sea ice area in the Arctic and the sea level pressure over the Beaufort High region. It is argued that as sea ice coverage is lost, static stability losses are severe in fall, resulting in enhanced evaporation, vertical motions, and weakening of the general large-scale anticyclonic circulation of the Beaufort High.

54 ENVIRONMENTAL SCIENCES↗

The 0E2 benchmarks for PWR UO 2 decay heat: an analysis from the NEA WPNCS

This paper presents the work performed in the subgroup 16 of the Working Party for Nuclear Criticality Safety (WPNCS) of the OECD Nuclear Energy Agency. The main goal was to define two decay heat benchmarks for Spent Nuclear Fuel (one pincell and one assembly), perform calculations and compare and analyze the results in light of existing calorimetric measurements. The selected case is the PWR UO2 assembly 0E2, irradiated at the Ringhals-3 reactor and measured at the Clab facility in Sweden. In total, 21 institutes worldwide participated to the exercise, leading to 55 calculated results (named C). It was found that the measured decay heat values (E) can be satisfactorily reproduced with two-dimensional assembly calculations, leading to an average C/E value of 0.99, with an uncertainty (or one standard deviation) of ±0.01.

11 NUCLEAR FUEL CYCLE AND FUEL MATERIALS↗

Interplanetary radio storms. 2: Emission levels and solar wind speed in the range 0.05-0.8 AU

Storms of interplanetary type III radio bursts (IP storms) are commonly observed in the interplanetry medium by the ISEE-3 radio instrument. This instrument has the capability of accurately determining the arrival direction of the radio emission. At each observing frequency, the storm radio sources are tracked as they cross the line-of-sight to the Sun. Usng a simple model, the emission levels are determined at a number of radio frequencies for four separate storms. The IP storm radiation is found to occur in regions of enhanced density at levels of 0.05 to 0.8 AU. The density in these enhancements falls off faster than R(-2). The solar wind speed in the storm region is also measured. The analysis is consistent with steady conditions in the storm region during a few days around the central meridian passage of the storm. The comparison with average in situ density measurements compiled from the HELIOS 1-2 observations favors type III storm burst radio emission at the harmonic of the local plasma frequency.

Bougeret, J. L.↗

Interplanetary radio storms. II - Emission levels and solar wind speed in the range 0.05-0.8 AU

Storms of interplanetary type III radio bursts (IP storms) are commonly observed in the interplanetary medium by the ISEE-3 radio instrument. This instrument has the capability of accurately determining the arrival direction of the radio emission. At each observing frequency, the storm radio sources are tracked as they cross the line-of-sight to the sun. Using a simple model, the emission levels are determined at a number of radio frequencies for four separate storms. The IP storm radiation is found to occur in regions of enhanced density at levels of 0.05 to 0.8 AU. The density in these enhancements falls off faster than R(-2). The solar wind speed in the storm region is also measured. The analysis is consistent with steady conditions in the storm region during a few days around the III storm burst radio emission at the harmonic of the local plasma frequency.

Bougeret, J.-L.↗

A computation of the stratospheric diabatic circulation using an accurate radiative transfer model

The global diabatic circulation is computed for the months of January, April, July and October over the altitude region 100 to 0.1 mb using an accurate troposphere-stratosphere radiative transfer model, SBUV and SME ozone data, and NMC temperatures. There is high correlation between the level of wave activity and the local departure of the atmosphere from radiative equilibrium. An excess in the globally averaged net stratospheric heating from 40 to 50 km is computed for all months, and a deficit from 50 to 60 km is computed during solstice. A 20 percent uniform reduction in ozone from 40 to 50 km, or a temperature perturbation with an increase of 5 K at 1 mb, will bring the atmosphere into global radiative equilibrium without significant impact on the diabatic circulation. In the transitional months of April and October, the net heating in the fall hemispheres are very similar, while substantial differences exist between the spring hemispheres.

Rosenfield, Joan E.↗

CIRCUMBINARY MAGNETOHYDRODYNAMIC ACCRETION INTO INSPIRALING BINARY BLACK HOLES

We have simulated the magnetohydrodynamic evolution of a circumbinary disk surrounding an equal-mass binary comprising two non-spinning black holes during the period in which the disk inflow time is comparable to the binary evolution time due to gravitational radiation. Both the changing spacetime and the binary orbital evolution are described by an innovative technique utilizing high-order post-Newtonian approximations. Prior to the beginning of the inspiral, the structure of the circumbinary disk is predicted well by extrapolation from Newtonian results: a gap of roughly two binary separation radii is cleared, and matter piles up at the outer edge of this gap as inflow is retarded by torques exerted by the binary; the accretion rate is roughly half its value at large radius. During inspiral, the inner edge of the disk initially moves inward in coordination with the shrinking binary, but-as the orbital evolution accelerates-the inward motion of the disk edge falls behind the rate of binary compression. In this stage, the binary torque falls substantially, but the accretion rate decreases by only 10%-20%. When the binary separation is tens of gravitational radii, the rest-mass efficiency of disk radiation is a few percent, suggesting that supermassive binary black holes could be very luminous at this stage of their evolution. Inner disk heating is modulated at a beat frequency comparable to the binary orbital frequency. However, a disk with sufficient surface density to be luminous may be optically thick, suppressing periodic modulation of the luminosity.

79 ASTRONOMY AND ASTROPHYSICS↗

A model for interphase chromosomes and evaluation of radiation-induced aberrations

We have developed a theoretical model for evaluating radiation-induced chromosomal exchanges by explicitly taking into account interphase (G(0)/G(1)) chromosome structure, nuclear organization of chromosomes, the production of double-strand breaks (DSBs), and the subsequent rejoinings in a faithful or unfaithful manner. Each of the 46 chromosomes for human lymphocytes (40 chromosomes for mouse lymphocytes) is modeled as a random polymer inside a spherical volume. The chromosome spheres are packed randomly inside a spherical nucleus with an allowed overlap controlled by a parameter Omega. The rejoining of DSBs is determined by a Monte Carlo procedure using a Gaussian proximity function with an interaction range parameter sigma. Values of Omega and sigma have been found which yield calculated results of interchromosomal aberration frequencies that agree with a wide range of experimental data. Our preferred solution is one with an interaction range of 0.5 microm coupled with a relatively small overlap parameter of 0.675 microm, which more or less confirms previous estimates. We have used our model with these parameter values and with resolution or detectability limits to calculate yields of translocations and dicentrics for human lymphocytes exposed to low-LET radiation that agree with experiments in the dose range 0.09 to 4 Gy. Five different experimental data sets have been compared with the theoretical results. Essentially all of the experimental data fall between theoretical curves corresponding to resolution limits of 1 Mbp and 20 Mbp, which may reflect the fact that different investigators use different limits for sensitivity or detectability. Translocation yields for mouse lymphocytes have also been calculated and are in good agreement with experimental data from 1 cGy to 10 cGy. There is also good agreement with recent data on complex aberrations. Our model is expected to be applicable to both low- and high-LET radiation, and we include a sample prediction of the yield of interchromosomal rejoining in the dose range 0.22 Gy to 2 Gy of 1000 MeV/nucleon iron particles. This dose range corresponds to average particle traversals per nucleus ranging from 1.0 to 9.12.

Non-NASA Center↗

MicroMAPS CO Measurements over North America and Europe during Summer-Fall 2004

The MicroMAPS instrument is a nadir-viewing, gas filter-correlated radiometer which operating in the 4.67 micrometer fundamental band of carbon monoxide. Originally designed and built for a space mission, this CO remote sensor is being flown in support of satellite validation and science instrument demonstrations for potential UAV applications. The MicroMAPS instrument system, as flown on Proteus, was designed by a senior student design project in the Aerospace Engineering Department, Virginia Tech, in Blacksburg, VA. and then revised by Systems Engineers at NASA Langley. The final instrument system was integrated and tested at NASA LaRC, in partnership with Scaled Composites and Virginia Space Grant Consortium (VSGC). VSGC supervised the fabrication of the nacelle that houses the instrument system on the right rear tail boom of Proteus. Full system integration and flight testing was performed at Scaled Composites, in Mojave, in June 2004. Its successful performance enabled participation in four international science missions on Proteus: in 2004, INTEX -NA over eastern North America in July, ADRIEX over the Mediterranean region and EAQUATE over the United Kingdom region in September,and TWP-ICE over Darwin, Australia and the surrounding oceans in Jan-Feb 2006. These flights resulted in nearly 300 hours of data. In parallel with the engineering developments, theoretical radiative transfer models were developed specifically for the MicroMAPS instrument system at the University of Virginia, Mechanical Engineering Department by a combined undergraduate and graduate student team. With technical support from Resonance Ltd. in June 2005, the MicroMAPS instrument was calibrated for the conditions under which the Summer-Fall 2004 flights occurred. The analyses of the calibration data, combined with the theoretical radiative transfer models, provide the first data reduction for the science flights reported here. These early results and comparisons with profile data from the NASA DC-8, the coincident AIRS CO retrievals, and selected CO measurements from the MOZAIC program will be presented.

Connors, Vickie S.↗

Workshop introduction

The Department of Energy's National Nuclear Security Administration's Global Threat Reduction Initiative (GTRI) has three subprograms that directly reduce the nuclear/radiological threat; Convert (Highly Enriched Uranium), Protect (Facilities), and Remove (Materials). The primary mission of the Off-Site Source Recovery Project (OSRP) falls under the 'Remove' subset. The purpose of this workshop is to provide a venue for joint-technical collaboration between the OSRP and the Nuclear Radiation Safety Service (NRSS). Eisenhower's Atoms for Peace initiative and the Soviet equivalent both promoted the spread of the paradoxical (peaceful and harmful) properties of the atom. The focus of nonproliferation efforts has been rightly dedicated to fissile materials and the threat they pose. Continued emphasis on radioactive materials must also be encouraged. An unquantifiable threat still exists in the prolific quantity of sealed radioactive sources (sources) spread worldwide. It does not appear that the momentum of the evolution in the numerous beneficial applications of radioactive sources will subside in the near future. Numerous expert studies have demonstrated the potentially devastating economic and psychological impacts of terrorist use of a radiological dispersal or emitting device. The development of such a weapon, from the acquisition of the material to the technical knowledge needed to develop and use it, is straightforward. There are many documented accounts worldwide of accidental and purposeful diversions of radioactive materials from regulatory control. The burden of securing sealed sources often falls upon the source owner, who may not have a disposal pathway once the source reaches the end of its useful life. This disposal problem is exacerbated by some source owners not having the resources to safely and compliantly store them. US Nuclear Regulatory Commission (NRC) data suggests that, in the US alone, there are tens of thousands of high-activity (IAEA Category I and II) sources in thousands of devices; and there are many more tens of thousands of smaller sources scattered among thousands of other NRC licensees. As a result of the ubiquitous nature and undeterminable number of current and legacy sources, even in developed countries they can be abandoned, disposed of in a haphazard manner, lost, stolen, and/or otherwise fallout of regulatory control. Supply and demand of sources, being market based, is more or less fluid. Normative security of radioactive sources exists, but varies in each country, and is loosely implemented through non-legally binding recommendations and standards provided by International Atomic Energy Agency technical documents and cooperation and through bilateral efforts such as this workshop where we share best-practices with one another. Much of the reason for the difficulty in securing sealed sources rests in the enormous need for their beneficial applications in the medical, industrial, and agricultural sectors. Alternative technologies to replace high-risk sources continue to be explored, but very few of these alternative solutions have reached the development stage for common usage and distribution. The beneficial uses of sources must be allowed to continue; however, to minimize the potential for their misuse, current controls and regulating mechanisms must be constantly evaluated to ensure the benefits gained outweigh potential risks. From a global perspective, an evaluation and modification of requirements over the entire life cycle of sources from their manufacture to their final disposition is required. The proper removal and disposal of vulnerable disused or orphan sources is essential to maintaining a safe operating environment. One of our goals in this workshop is to share our methodologies for recovering sources and learn how they differ or are similar to the challenges faced in recovering, storing, and disposing of sources in the Republic of Georgia . The suggestions we will make are flexible in allowing for the imperfect situations and capabilities we have all encountered in source recovery efforts. We have designed a table-top exercise specifically to address your concerns about the prevention and mitigation of contaminated facilities, soil, containers, and sources. Our discussion begins with an overview and video of the OSRP along with a brief on our projects ongoing international cooperation and activities. A presentation will be given by the NRSS illustrating the successes and challenges of source management in Georgia. A brief overview will be given of selected significant cases of the intentional misuse of sources. This will be followed by two comprehensive discussions focusing on the decontamination from the facility perspective down to the issues of container and source leakage. The second day will begin with the abovementioned table-top exercise on contamination control. On the third day, a second presentation from the NRSS will open up the session.

45 MILITARY TECHNOLOGY, WEAPONRY, AND NATIONAL DEF↗

Observations of Subvisible Cirrus Clouds and Gravity Waves at the Tropical Tropopause

Thin, subvisible cirrus (SVC) clouds at the tropical tropopause have been observed by a number of methods in a variety of observational programs, including in situ sampling and aircraft and space-based lidar. Modeling studies suggest that these clouds play an important role in dehydrating tropospheric air as it enters the stratosphere. This is because particles large enough to have significant fall speeds can form under the conditions of slow cooling that are implied by the large horizontal extent of the SVC sheets. The IR radiation that these clouds absorb, and the upward vertical motion this implies, also makes them candidates for a tropical troposphere-to-stratosphere mass transfer mechanism. They may also play a role in the earth's radiation budget. These sheets were observed on five flights during the Tropical Ozone Transport Experiment (TOTE) by the NASA Langley DIAL lidar aboard NASA's DC-8 research aircraft operating during December 1995 and February 1996 south of Hawaii. The relationship of the SVC's observed during TOTE to convection was not a simple one. One class of SVC's are within 1000 km of the persistent strong convection near 15S (the SPCZ). Trajectory analyses indicated that the SVC air masses have in fact passed through the SPCZ within a few days of observation. These clouds are very close to the tropopause, with maximum potential temperatures not much higher than 370K, consistent with in situ water and total water measurements near the tropopause made during the Stratosphere Troposphere Exchange Project in January 1987 at Darwin, Australia. A second class of SVC's are not immediately downstream of convection. These clouds tend to be higher, reaching potential temperatures of 390K or more. Trajectory analyses indicate that the air in these SVC's originates either in the equatorial western Pacific or along the subtropical jet. In any case, the warm temperatures the SVC air masses encounter just prior to the observation time along the back trajectory imply that the clouds cannot be residual particles from cirrus blowoff, but must form locally as the air move upward and equatorward south of Hawaii. Since all the parcels have encountered colder temperatures than those at the time of observation early in their history, subsynoptic scale temperatures colder than the analysis temperatures appear to be required to explain the formation of ice particles. In fact, the sloping shapes of the SVC's do suggest that they are gravity or inertia-gravity waves. In situ meteorological measurements made by the ER-2 within a day of the DC-8 remote lidar observations show a gravity wave structure near the equator with an estimated period of about 30 hours. This is sufficiently long to allow large particles to form and fall out (thus allowing dehydration). Other ER-2 flights south of Hawaii at other times of year show gravity and inertia-gravity waves with a poleward wavenumber component and significant (5 degrees peak to peak) temperature perturbation.

Pfister, Leonhard↗

WE-A-BRC-00: The Quality Gap

Quality and safety in healthcare are inextricably linked. There are compelling data that link poor quality radiation therapy to inferior patient survival. Radiation Oncology clinical trial protocol deviations often involve incorrect target volume delineation or dosing, akin to radiotherapy incidents which also often involve partial geometric miss or improper radiation dosing. When patients with radiation protocol variations are compared to those without significant protocol variations, clinical outcome is negatively impacted. Traditionally, quality assurance in radiation oncology has been driven largely by new technological advances, and safety improvement has been driven by reactive responses to past system failures and prescriptive mandates recommended by professional organizations and promulgated by regulators. Prescriptive approaches to quality and safety alone often do not address the huge variety of process and technique used in radiation oncology. Risk-based assessments of radiotherapy processes provide a mechanism to enhance quality and safety, both for new and for established techniques. It is imperative that we explore such a paradigm shift at this time, when expectations from patients as well as providers are rising while available resources are falling. There is much we can learn from our past experiences to be applied towards the new risk-based assessments. Learning Objectives: Understand the impact of clinical and technical quality on outcomes Understand the importance of quality care in radiation oncology Learn to assess the impact of quality on clinical outcomes D. Followill, NIH Grant CA180803.

60 APPLIED LIFE SCIENCES↗

WE-A-BRC-01: Introduction to the Certificate Course

Quality and safety in healthcare are inextricably linked. There are compelling data that link poor quality radiation therapy to inferior patient survival. Radiation Oncology clinical trial protocol deviations often involve incorrect target volume delineation or dosing, akin to radiotherapy incidents which also often involve partial geometric miss or improper radiation dosing. When patients with radiation protocol variations are compared to those without significant protocol variations, clinical outcome is negatively impacted. Traditionally, quality assurance in radiation oncology has been driven largely by new technological advances, and safety improvement has been driven by reactive responses to past system failures and prescriptive mandates recommended by professional organizations and promulgated by regulators. Prescriptive approaches to quality and safety alone often do not address the huge variety of process and technique used in radiation oncology. Risk-based assessments of radiotherapy processes provide a mechanism to enhance quality and safety, both for new and for established techniques. It is imperative that we explore such a paradigm shift at this time, when expectations from patients as well as providers are rising while available resources are falling. There is much we can learn from our past experiences to be applied towards the new risk-based assessments. Learning Objectives: Understand the impact of clinical and technical quality on outcomes Understand the importance of quality care in radiation oncology Learn to assess the impact of quality on clinical outcomes D. Followill, NIH Grant CA180803.

60 APPLIED LIFE SCIENCES↗

WE-A-BRC-02: Lessons Learned: Clinical Trials and Operations

Quality and safety in healthcare are inextricably linked. There are compelling data that link poor quality radiation therapy to inferior patient survival. Radiation Oncology clinical trial protocol deviations often involve incorrect target volume delineation or dosing, akin to radiotherapy incidents which also often involve partial geometric miss or improper radiation dosing. When patients with radiation protocol variations are compared to those without significant protocol variations, clinical outcome is negatively impacted. Traditionally, quality assurance in radiation oncology has been driven largely by new technological advances, and safety improvement has been driven by reactive responses to past system failures and prescriptive mandates recommended by professional organizations and promulgated by regulators. Prescriptive approaches to quality and safety alone often do not address the huge variety of process and technique used in radiation oncology. Risk-based assessments of radiotherapy processes provide a mechanism to enhance quality and safety, both for new and for established techniques. It is imperative that we explore such a paradigm shift at this time, when expectations from patients as well as providers are rising while available resources are falling. There is much we can learn from our past experiences to be applied towards the new risk-based assessments. Learning Objectives: Understand the impact of clinical and technical quality on outcomes Understand the importance of quality care in radiation oncology Learn to assess the impact of quality on clinical outcomes D. Followill, NIH Grant CA180803.

60 APPLIED LIFE SCIENCES↗

WE-A-BRC-03: Lessons Learned: IROC Audits

Quality and safety in healthcare are inextricably linked. There are compelling data that link poor quality radiation therapy to inferior patient survival. Radiation Oncology clinical trial protocol deviations often involve incorrect target volume delineation or dosing, akin to radiotherapy incidents which also often involve partial geometric miss or improper radiation dosing. When patients with radiation protocol variations are compared to those without significant protocol variations, clinical outcome is negatively impacted. Traditionally, quality assurance in radiation oncology has been driven largely by new technological advances, and safety improvement has been driven by reactive responses to past system failures and prescriptive mandates recommended by professional organizations and promulgated by regulators. Prescriptive approaches to quality and safety alone often do not address the huge variety of process and technique used in radiation oncology. Risk-based assessments of radiotherapy processes provide a mechanism to enhance quality and safety, both for new and for established techniques. It is imperative that we explore such a paradigm shift at this time, when expectations from patients as well as providers are rising while available resources are falling. There is much we can learn from our past experiences to be applied towards the new risk-based assessments. Learning Objectives: Understand the impact of clinical and technical quality on outcomes Understand the importance of quality care in radiation oncology Learn to assess the impact of quality on clinical outcomes D. Followill, NIH Grant CA180803.

60 APPLIED LIFE SCIENCES↗

HDG-1 Fiber Bragg grating data analysis

The main goal of the High dose graphite 1 Advanced test reactor experiment was to study nuclear grade graphite at high fluences. Additional supplementary optical fiber instrumentation was added to this long duration experiment for instrumentation development purposes. The supplementary instrumentation consisted of two pure silica core, fluorine doped cladding optical fibers each etched with 9 fiber Bragg gratings, one fiber being heat treated for 9 hours at 750 C and 16 hours at 750 C, the other being heat treated for 24 hours at 550 C and 48 hours at 650 C. Fiber Bragg gratings are known to have issues of measurement drift when in high temperature and high radiation environments like what is encountered in the Advanced test reactor. At the culmination of this experiment, the optical fibers saw ~1.3E21 n/cm2 total fluence, which is at the highest fluences that fiber Bragg gratings have been studied to date. Reported here is the analysis of this data including radiation induced shift and changes in sensitivity.

46 - INSTRUMENTATION RELATED TO NUCLEAR SCIENCE AN↗

Radiation-Induced Damage of Silicon-Carbide Diodes by High-Energy Particles

The radiation hardness of three types of commercial Schottky rectifier diodes based on silicon carbide (4H-SiC, base layer doping level (3–7) × 10{sup 15} cm{sup –3}) under electron (0.9 or 3.5 MeV electrons) and proton irradiation (15 MeV protons) is studied. The forward and reverse current–voltage characteristics of the diodes are monitored. In the initial state, the diodes have a breakdown voltage of 1–2 kV and an almost ideal forward current–voltage characteristic. It is found that the series resistance of the diodes is the most sensitive to radiation and governs the radiation hardness. This resistance grows by nearly 10 orders of magnitude and reaches a value of 10{sup 9} Ω at high doses. The threshold doses of electron irradiation fall within the range D{sub th} ≈ (0.5–2) × 10{sup 16} cm{sup –2} and depend on the electron energy and doping level of the base layer, and those of proton irradiation, D{sub th} ≈ 5 × 10{sup 13} cm{sup –2}.

75 CONDENSED MATTER PHYSICS, SUPERCONDUCTIVITY AND↗

Estimation of the Mass Absorption Cross Section of the Organic Carbon Component of Aerosols in the Mexico City Metropolitan Area

Data taken from the MCMA-2003 and the 2006 MILAGRO field campaigns are used to examine the absorption of solar radiation by the organic component of aerosols. Using irradiance data from an Multi-Filter Rotating Shadowband Radiometer (MFRSR) and an actinic flux spectroradiometer, we find aerosol single scattering albedo, ω - 0,λ, as a function of wavelength, λ. We find that in near-UV spectral range (defined here as 250 nm to 400 nm) ω - 0,λ is much lower compared to ω - 0,λ at 500 nm suggesting enhanced absorption in the near-UV range. Absorption by elemental carbon, dust, or gas cannot account for this enhanced absorption leaving only the organic part of the aerosol to account for it. We use data from a surface deployed Aerodyne Aerosol Mass Spectrometer (AMS) along with the inferred ω - 0,λ to estimate the Mass Absorption Cross-section (MAC) for the organic carbon. We find that the MAC is about 10.5 m2/g at 300 nm and falls close to zero at about 500 nm; values that are roughly consistent with other estimates of organic carbon MAC. These MAC values can be considered as “radiatively correct” because when used in radiative transfer calculations the calculated irradiances match the measured irradiances at the wavelengths considered here. The uncertainties of individual estimates are quite large, ±30% at 300 nm for the random error, and even larger for a worst-case estimate of the systematic error, ±80%. The error represents the unusual circumstance where no error cancellation is permitted, and is unlikely ever to be realized.

54 ENVIRONMENTAL SCIENCES↗