Engineering Papers⌕ Search

SEARCH · Engineering Papers

Results for “RAD”

Search indexed NASA NTRS and DOE OSTI research on propulsion, heat transfer, battery materials and energy systems. Follow report and document links to the original sources.

Quote a phrase for an exact phrase match. Source license links do not imply unrestricted reuse.

At least 433 records · Page 24

First study of the CP-violating phase and decay-width difference in B s 0 → ψ ( 2 S ) φ decays

A time-dependent angular analysis of B s 0 → ψ ( 2 S ) φ decays is performed using data recorded by the LHCb experiment. The data set corresponds to an integrated luminosity of 3.0fb –1 collected during Run 1 of the LHC. The CP-violating phase and decay-width difference of the B$^{0}_{s}$ system are measured to be φ s =0.23$^{+0.29}_{–0.28}$ ± 0.02 rad and ΔΓ s =0.066$^{+0.041}_{–0.044}$ ± 0.007 ps –1 , respectively, where the first uncertainty is statistical and the second systematic. This is the first time that φ s and ΔΓ s have been measured in a decay containing the ψ(2S) resonance.

72 PHYSICS OF ELEMENTARY PARTICLES AND FIELDS↗

Identifying paleowater in California drinking water wells

Identification of paleowater in aquifers tapped for the public water supply is important both for sound water management, because paleowater is likely to be withdrawn unsustainably in high demand regions in the absence of large scale artificial recharge operations, and for contamination susceptibility assessment, because paleowater is typically isolated from contamination sources. In this study, paleowater, which herein includes pre-Holocene groundwater and also water that recharged well before the onset of significant human alteration of the hydrologic system in California, is identified using three key isotopic indicators of groundwater residence time: tritium ( 3 H), radiocarbon ( 14 C), and radiogenic helium-4 ( 4 He rad ). In this work, we compared results of these three tracers from a unique data set of more than 2000 wells that are predominantly long-screened drinking water production wells. Although considerable uncertainty is associated with calculated apparent ages for individual samples, non-parametric statistical tests indicate that the composite set of isotopic indicators support classification of samples into categories that allow identification of wells most likely to produce paleowater. Approximately 7% of the wells included in the study show strong evidence for producing paleowater, with screens extending greater than 146 m below ground surface, in which 3 H activity is less than 1 pCi/L, 14C activity is less than 40.9 pmC, and 4Herad concentration exceeds 7.4 × 10 –8 cm 3 STP/g water . An additional 22% of wells produce mixed-age water with a component of paleowater, with screens extending greater than 95 m below ground surface, in which 3 H is less than 5 pCi/L, and 14C activity is less than 95.91 pmC. Wells in desert basins of southeastern California and wells in the southwestern quadrant of the Central Valley are most likely to produce paleowater that is pre-Holocene in age. Very few wells in the northwestern portion of the state, the foothills and Sierra Nevada regions, and coastal basins with intensive artificial recharge activities are categorized as producing paleowater. Climate is the primary control on paleowater occurrence, with arid portions of the state that were wetter during the Pleistocene having the largest number of wells categorized as producing paleowater. Secondarily, paleowater is found at the end of very long flow paths in confined aquifers, e.g., in the center of the Northern Sacramento Valley. In contrast, paleowater may be masked in areas where unconfined or semi-confined conditions allow substantial mixing between modern recharge and paleowater. Modern, artificially recharged water has replaced very old groundwater on a large scale in urban coastal basins.

54 ENVIRONMENTAL SCIENCES↗

A review of criticality dosimetry at the Y-12 National Security Complex and practical importance of dose accuracy in emergency response

A nuclear criticality results in the emission of both neutron and gamma radiation and can produce doses to personnel near the event that exceed 0.1 Gy (10 rad). The primary purpose of nuclear accident dosimetry is to rapidly identify affected personnel in need of prompt medical treatment and to reassure personnel who have been only minimally exposed. While accurate dosimetry is desired, it must be recognized that dose determinations made from whole-body dosimeters or simple triage methods are very rough estimates and contain significant uncertainties. Even when accounting for factors like varying neutron energy spectra, mean photon energies, body orientation within the radiation field, and transient effects on dosimeter response, etc., the end value is a dosimetric quantity defined for very specific radiological conditions and determined within a simple phantom usually at a single depth. Of more importance is the biological response to the radiation, which will vary by person and can be affected by the individual’s radiation sensitivity, age, gender, mass, and underlying health conditions. The overall biological, person-specific response to a given dose cannot be precisely determined except by patient symptom observation and individual biological dosimetry (e.g. chromosome analysis, lymphocyte ratios, etc.). This work describes and discusses the criticality accident dosimetry program at the Y-12 National Security Complex, a United States Department of Energy National Nuclear Security Administration facility. In conclusion, the primary goals of the Y-12 accident dosimetry program are, among others, the rapid identification of significantly exposed persons, prompt routing of exposed workers for medical evaluation and treatment, and the ultimate processing of dosimeters to assign doses to personnel.

61 RADIATION PROTECTION AND DOSIMETRY↗

Layered shielding design for an active neutron interrogation system

The use of source and detector shields in active neutron interrogation can improve detector signal. In simulations, a shielded detector with a source rotated π/3 rad relative to the opening decreased neutron flux roughly three orders of magnitude. Several realistic source and detector shield configurations were simulated. A layered design reduced neutron and secondary photon flux in the detector by approximately one order of magnitude for a deuterium–tritium source. The shield arrangement can be adapted for a portable, modular design.

46 INSTRUMENTATION RELATED TO NUCLEAR SCIENCE AND ↗

Early treatment of chlorine-induced airway hyperresponsiveness and inflammation with corticosteroids

Chlorine (Cl{sub 2}) is an industrial gas that is highly toxic and irritating when inhaled causing tissue damage and an acute inflammatory response in the airways followed by a long-term airway dysfunction. The aim of this study was to evaluate whether early anti-inflammatory treatment can protect against the delayed symptoms in Cl{sub 2}-exposed mice. BALB/c mice were exposed by nose-only inhalation using 200 ppm Cl{sub 2} during 15 min. Assessment of airway hyperresponsiveness (AHR), inflammatory cell counts in bronchoalveolar lavage, occurrence of lung edema and lung fibrosis were analyzed 24 h or 14 days post-exposure. A single dose of the corticosteroid dexamethasone (10 or 100 mg/kg) was administered intraperitoneally 1, 3, 6, or 12 h following Cl{sub 2} exposure. High-dose of dexamethasone reduced the acute inflammation if administered within 6 h after exposure but treated animals still displayed a significant lung injury. The effect of dexamethasone administered within 1 h was dose-dependent; high-dose significantly reduced acute airway inflammation (100 mg/kg) but not treatment with the relatively low-dose (10 mg/kg). Both doses reduced AHR 14 days later, while lung fibrosis measured as collagen deposition was not significantly reduced. The results point out that the acute inflammation in the lungs due to Cl{sub 2} exposure only partly is associated with the long-term AHR. We hypothesize that additional pathogenic mechanisms apart from the inflammatory reactions contribute to the development of long-term airway dysfunction. By using this mouse model, we have validated early administration of corticosteroids in terms of efficacy to prevent acute lung injury and delayed symptoms induced by Cl{sub 2} exposure. - Highlights: • Inhalation of Cl{sub 2} may lead to a long-standing airway hyperresponsiveness. • The symptoms in Cl{sub 2}-exposed mice are similar to those described for RADS in humans. • Corticosteroids prevent delayed symptoms such as AHR in Cl{sub 2}-induced lung injury. • Early medical intervention of corticosteroids is of importance. • Treatment with corticosteroids alone is insufficient to counteract acute lung injury.

60 APPLIED LIFE SCIENCES↗

Enhanced susceptibility of ovaries from obese mice to 7,12-dimethylbenz[a]anthracene-induced DNA damage

7,12-Dimethylbenz[a]anthracene (DMBA) depletes ovarian follicles and induces DNA damage in extra-ovarian tissues, thus, we investigated ovarian DMBA-induced DNA damage. Additionally, since obesity is associated with increased offspring birth defect incidence, we hypothesized that a DMBA-induced DNA damage response (DDR) is compromised in ovaries from obese females. Wild type (lean) non agouti (a/a) and KK.Cg-Ay/J heterozygote (obese) mice were dosed with sesame oil or DMBA (1 mg/kg; intraperitoneal injection) at 18 weeks of age, for 14 days. Total ovarian RNA and protein were isolated and abundance of Ataxia telangiectasia mutated (Atm), X-ray repair complementing defective repair in Chinese hamster cells 6 (Xrcc6), breast cancer type 1 (Brca1), Rad 51 homolog (Rad51), poly [ADP-ribose] polymerase 1 (Parp1) and protein kinase, DNA-activated, catalytic polypeptide (Prkdc) were quantified by RT-PCR or Western blot. Phosphorylated histone H2AX (γH2AX) level was determined by Western blotting. Obesity decreased (P < 0.05) basal protein abundance of PRKDC and BRCA1 proteins but increased (P < 0.05) γH2AX and PARP1 proteins. Ovarian ATM, XRCC6, PRKDC, RAD51 and PARP1 proteins were increased (P < 0.05) by DMBA exposure in lean mice. A blunted DMBA-induced increase (P < 0.05) in XRCC6, PRKDC, RAD51 and BRCA1 was observed in ovaries from obese mice, relative to lean counterparts. Taken together, DMBA exposure induced γH2AX as well as the ovarian DDR, supporting that DMBA causes ovarian DNA damage. Additionally, ovarian DDR was partially attenuated in obese females raising concern that obesity may be an additive factor during chemical-induced ovotoxicity. - Highlights: • DMBA induces markers of ovarian DNA damage. • Obesity induces low level ovarian DNA damage. • DMBA-induced DNA repair response is altered by obesity.

60 APPLIED LIFE SCIENCES↗

Femtosecond mega-electron-volt electron microdiffraction

To understand and control the basic functions of physical, chemical and biological processes from micron to nano-meter scale, an instrument capable of visualizing transient structural changes of inhomogeneous materials with atomic spatial and temporal resolutions, is required. One such technique is femtosecond electron microdiffraction, in which a short electron pulse with femtosecond-scale duration is focused into a micron-scale spot and used to obtain diffraction images to resolve ultrafast structural dynamics over a localized crystalline domain. In this letter, we report the experimental demonstration of time-resolved mega-electron-volt electron microdiffraction which achieves a 5 μm root-mean-square (rms) beam size on the sample and a 110 fs rms temporal resolution. Using pulses of 10k electrons at 4.2 MeV energy with a normalized emittance 3 nm-rad, we obtained high quality diffraction from a single 10 μm paraffin ( C 44 H 90 ) crystal. The phonon softening mode in optical-pumped polycrystalline Bi was also time-resolved, demonstrating the temporal resolution limits of the instrument. In conclusion, this new characterization capability will open many research opportunities in material and biological sciences.

36 MATERIALS SCIENCE↗

Pointing stabilization of a 1 Hz high-power laser via machine learning

Abstract High-power lasers are vital for particle acceleration, imaging, fusion and materials processing, requiring precise control and high-energy delivery. Laser plasma accelerators (LPAs) demand laser positional stability at focus to ensure consistent electron beams in applications such as X-ray free-electron lasers and high-energy colliders. Achieving this stability is especially challenging for the low-repetition-rate lasers in current LPAs. We present a machine learning method that predicts and corrects laser pointing instabilities in real-time using a high-frequency pilot beam. By preemptively adjusting a correction mirror, this approach overcomes traditional feedback limits. Demonstrated on the BELLA petawatt laser operating at the terawatt level (30 mJ amplification), our method achieved root mean square pointing stabilization of 0.34 and 0.59 $\unicode{x3bc} \mathrm{rad}$ in the x and y directions, reducing jitter by 65% and 47%, respectively. This is the first successful application of predictive control for shot-to-shot stabilization in low-repetition-rate laser systems, paving the way for full-energy petawatt lasers and transformative advances across science, industry and security.

Amodio, Alessio↗

Online, real-time analysis of highly complex processing streams: Quantification of analytes in Hanford tank sample

Processing of hazardous materials is a crucial example of where on-line monitoring can significantly reduce operation risk, cost, and time. This is particularly true in the case of the Hanford site, where nuclear materials from the cold war era are being processed for environmental cleanup efforts. In exceedingly complex streams such as those at Hanford, on-line and real-time monitoring can be a challenge due to complexity of signals. Further obstacles are imposed by the caustic nature of processing streams as well as the radiation damage inflicted on instruments and probes. On-line monitoring based on Raman spectroscopy enables the detection of many Hanford tank species of interest, and was demonstrated here on nine chemical species that comprise the majority of tank waste by volume, including Al(OH)4-, C2O42-, CO32-, CrO42-, NO32-, NO3-, OH-, PO43-, SO42-. Real-time analysis of Raman signal allows for immediate quantification of target analytes and was successfully accomplished through the use of chemometric models. Furthermore, irradiation tests reveal Raman monitoring systems can effectively continue to operate even after receiving 1·107 Rad of gamma dose. The on-line, real-time monitoring system developed here was successfully used to simultaneously quantify nine target analytes in a real samples collected from Hanford tank AP-105.

Lines, Amanda M.↗

Molecular and Dissociative Adsorption of Water on (TiO 2 ) n Clusters, n = 1–4

In the low energy structures of the (TiO 2 ) n (H 2 O) m (n ≤ 4, m ≤ 2n) and (TiO 2 ) 8 (H 2 O) m (m = 3, 7, 8) clusters were predicted using a global geometry optimization approach, with a number of new lowest energy isomers being found. Water can molecularly or dissociatively adsorb on pure and hydrated TiO 2 clusters. Dissociative adsorption is the dominant reaction for the first two H 2 O adsorption reactions for n = 1, 2, and 4, for the first three H 2 O adsorption reactions for n = 3, and for the first four H 2 O adsorption reactions for n = 8. As more H 2 O’s are added to the hydrated (TiO 2 )n cluster, dissociative adsorption becomes less exothermic as all the Ti centers become 4-coordinate. Furthermore two types of bonds can be formed between the molecularly adsorbed water and TiO 2 clusters: a Lewis acid–base Ti–O(H 2 ) bond or an O···H hydrogen bond. The coupled cluster CCSD(T) results show that at 0 K the H 2 O adsorption energy at a 4-coordinate Ti center is ~15 kcal/mol for the Lewis acid–base molecular adsorption and ~7 kcal/mol for the H-bond molecular adsorption, in comparison to that of 8–10 kcal/mol for the dissociative adsorption. The cluster size and geometry independent dehydration reaction energy, ED, for the general reaction 2(-TiOH) → -TiOTi– + H 2 O at 4-coordinate Ti centers was estimated from the aggregation reaction of nTi(OH) 4 to form the monocyclic ring cluster (TiO 3 H 2 ) n + nH 2 O. E D is estimated to be -8 kcal/mol, showing that intramolecular and intermolecular dehydration reactions are intrinsically thermodynamically allowed for the hydrated (TiO 2 ) n clusters with all of the Ti centers 4-coordinate, which can be hindered by cluster geometry changes caused by such processes. Finally by bending force constants for the TiOTi and OTiO bonds are determined to be 7.4 and 56.0 kcal/(mol·rad 2 ). Infrared vibrational spectra were calculated using density functional theory, and the new bands appearing upon water adsorption were assigned.

74 ATOMIC AND MOLECULAR PHYSICS↗

Superradiance and Directional Exciton Migration in Metal–Organic Frameworks

Crystalline metal–organic frameworks (MOFs) are promising synthetic analogues of photosynthetic light-harvesting complexes (LHCs). The precise assembly of linkers (organic chromophores) around the topology-defined pores offers the evolution of unique photophysical behaviors that are reminiscence of LHCs. These include MOF excited states with photoabsorbed energy that is spatially dispersed over multiple linkers defining the molecular excitons. The multilinker molecular excitons display superradiance–a hallmark of coupled oscillators seen in LHCs–with radiative rate constant (k rad ) exceeding that of a single linker. Our theoretical model and experimental results on three zirconium MOFs, namely, PCN-222(Zn), NU-1000, and SIU-100, with similar topology but varying linkers suggest that the size of such molecular excitons depends on the electronic symmetry of the linker. This multilinker exciton model effectively predicts the energy transfer rate constant; corresponding single-step exciton hopping time, ranging from a few picoseconds in SIU-100 and NU-1000 to a few hundreds of picoseconds in PCN-222(Zn), matches well with the experimental data. The model also predicts the anisotropy of exciton displacement with preferential migration along the crystallographic c-axis. Overall, these findings establish various missing links defining the exciton size and dynamics in MOF-assembled linkers. Furthermore, the understandings will provide design principles, especially, positioning the catalysts or electrode relative to the linker orientation for low-density solar energy conversion systems.

37 INORGANIC, ORGANIC, PHYSICAL, AND ANALYTICAL CH↗

Gigahertz-frequency acousto-optic phase modulation of visible light in a CMOS-fabricated photonic circuit

Optical phase modulators operating at visible wavelengths are essential components for photonic technologies such as those for quantum control, communications, and laser ranging. However, they remain challenging to implement in scalable, integrated platforms capable of handling high optical powers. Here we present a visible-light, gigahertz-frequency acousto-optic phase modulator, fabricated on a 200-mm wafer in a volume CMOS foundry, that supports greater than 500 mW of optical power at 730 nm. The device combines a piezoelectric transducer and a photonic waveguide within a single, wavelength-scale structure that confines both a propagating optical mode and an electrically excitable breathing-mode mechanical resonance. By tuning the device’s geometry to optimize the optomechanical interaction, we achieve modulation depths up to 4.85 rad with 80 mW of applied microwave power at 2.31 GHz in a 2-mm-long device. This corresponds to resonant modulation figures of merit of V π = 1.32V and V π ⋅ L = 0.26V cm. To our knowledge, this is the lowest V π ever demonstrated in any acousto-optic phase modulator and represents a 15-fold reduction in V π and a 100-fold reduction in required microwave power relative to state-of-the-art modulators with high visible-wavelength power handling commonly employed in quantum control systems.

Freedman, Jacob M. [Univ. of Arizona, Tucson, AZ (↗

Developing radiation tolerant polymer nanocomposites using C 60 as an additive

In nuclear facilities utilizing plutonium, polymeric materials are subjected to long-term, close-contact, and continuous α radiation exposure, which can lead to compounding material degradation and eventual failure. Herein we model the attenuation of α particles by linear-low-density polyethylene (LLDPE), polyvinyl alcohol (PVA) thin films, and C 60 using Monte Carlo N-Particle Extended (MCNPX) software. The degradation of these materials was investigated experimentally by irradiating them with a beam of α particles of 5.8 MeV energy at a tandem Van de Graaff accelerator delivering a dose rate of 2.95 × 10 6 rad s –1 over a 7.1 mm 2 sample area. Our development of a method to test α particle-induced material degradation using a tandem accelerator is significant as degradation from naturally occurring α sources (i.e. Pu, Am) occurs too slowly for these sources to be used in practical experiments. Our results show that PVA nanocomposites containing 5 wt% C 60 were found to withstand about 7 times the α dose of undoped PVA films before a puncture in the film was detected. When these films were adhered to a LLDPE sheet the dual layer polymer was capable of withstanding about 13 times the dose of LLDPE and nearly twice the dose of the doped PVA thin film alone. Doping polymers with C 60 is an attractive way to generate more durable, radiation tolerant materials without increasing the thickness of the material which would lead to greater waste for disposal. Furthermore, the results herein help to resolve a prevalent technical challenge faced in nuclear facilities that utilize polymeric materials for nuclear processing and disposal.

36 MATERIALS SCIENCE↗

Comparative analysis of atmospheric parameters from high-resolution spectroscopic sky surveys: APOGEE, GALAH, Gaia -ESO

SDSS-IV APOGEE-2, GALAH, and Gaia-ESO are high-resolution, ground-based, multi-object spectroscopic surveys providing fundamental stellar atmospheric parameters and multiple elemental abundance ratios for hundreds of thousands of stars of the Milky Way. Data from these and other surveys contribute to investigations of the history and evolution of the Galaxy. We undertake a comparison between the most recent data releases of these surveys to investigate the accuracy and precision of derived parameters by placing the abundances on an absolute scale. We also discuss the correlations in parameter and abundance differences as a function of main parameters. Uncovering the variants provides a basis to continue the efforts of future sky surveys. Quality samples from the APOGEE-GALAH (15 537 stars), APOGEE-GES (804 stars), and GALAH-GES (441 stars) overlapping catalogs were collected. We investigated the mean variants between the surveys, and linear trends were also investigated. We compared the slope of correlations and mean differences with the reported uncertainties. The average and scatter of v rad , T eff , log g, [M/H], and v micro , along with numerous species of elemental abundances in the combined catalogs, show that in general there is a good agreement between the surveys. We find large radial velocity scatters ranging from 1.3 km s -1 to 4.4 km s -1 when comparing the three surveys. We observe some weak trends (e.g., in ΔT eff vs. Δlog g for the APOGEE-GES stars) and a clear correlation in the v micro - Δv micro planes in the APOGEE-GALAH common sample. For [α/H], [Ti/H] (APOGEE-GALAH giants), and [Al/H] (APOGEE-GALAH dwarfs) potential strong correlations are discovered as a function of the differences in the main atmospheric parameters, and we also find weak trends for other elements. In general we find good agreement between the three surveys within their respective uncertainties. However, there are certain regimes in which strong variants exist, which we discuss. There are still offsets larger than 0.1 dex in the absolute abundance scales.

79 ASTRONOMY AND ASTROPHYSICS↗

First polarization study of the M87 jet and active galactic nuclei at submillimeter wavelengths with ALMA

We investigated the polarization and Faraday properties of Messier 87 (M87) and seven other radio-loud active galactic nuclei (AGNs) at λ0.87 mm (345 GHz) using the Atacama Large Millimeter/submillimeter Array (ALMA). Our goal was to characterize the linear polarization (LP) fractions, measure Faraday rotation measures (RMs), and examine the magnetic field structures in the emission regions of these AGNs. We conducted full-polarization observations as part of the ALMA Band 7 very long baseline interferometry (VLBI) commissioning during the April 2021 Event Horizon Telescope (EHT) campaign. We analyzed the LP fractions and RMs to assess the nature of Faraday screens and magnetic fields in the submillimeter emission regions. We find LP fractions between 1% and 17% and RMs exceeding 10 5 rad m −2 , which are 1–2 orders of magnitude higher than typically observed at longer wavelengths (λ>3 mm). This suggests denser Faraday screens or stronger magnetic fields. Additionally, we present the first submillimeter polarized images of the M87 jet and the observed AGNs, revealing RM gradients and sign reversals in the M87 jet indicative of a kiloparsec-scale helical magnetic field structure. Our results provide essential constraints for calibrating, analyzing, and interpreting VLBI data from the EHT at 345 GHz, representing a critical step toward submillimeter VLBI imaging.

79 ASTRONOMY AND ASTROPHYSICS↗

Photoelectron angular distributions from autoionizing 4s{sup 1}4p{sup 6}6p{sup 1} states in atomic krypton probed with femtosecond time resolution

Photoelectron angular distributions (PADs) are obtained for a pair of 4s{sup 1}4p{sup 6}6p{sup 1} (a singlet and a triplet) autoionizing states in atomic krypton. A high-order harmonic pulse is used to excite the pair of states and a time-delayed 801 nm ionization pulse probes the PADs to the final 4s{sup 1}4p{sup 6} continuum with femtosecond time resolution. The ejected electrons are detected with velocity map imaging to retrieve the time-resolved photoelectron spectrum and PADs. The PAD for the triplet state is inherently separable by virtue of its longer autoionization lifetime. Measuring the total signal over time allows for the PADs to be extracted for both the singlet state and the triplet state. Anisotropy parameters for the triplet state are measured to be {beta}{sub 2}= 0.55 {+-} 0.17 and {beta}{sub 4}=-0.01 {+-} 0.10, while the singlet state yields {beta}{sub 2}= 2.19 {+-} 0.18 and {beta}{sub 4}= 1.84 {+-} 0.14. For the singlet state, the ratio of radial transition dipole matrix elements, X, of outgoing S to D partial waves and total phase shift difference between these waves, {Delta}, are determined to be X= 0.56 {+-} 0.08 and {Delta}= 2.19 {+-} 0.11 rad. The continuum quantum defect difference between the S and D electron partial waves is determined to be -0.15 {+-} 0.03 for the singlet state. Based on previous analyses, the triplet state is expected to have anisotropy parameters independent of electron kinetic energy and equal to {beta}{sub 2}= 5/7 and {beta}{sub 4}=-12/7. Deviations from the predicted values are thought to be a result of state mixing by spin-orbit and configuration interactions in the intermediate and final states; theoretical calculations are required to quantify these effects.

74 ATOMIC AND MOLECULAR PHYSICS↗

Observation of impurity free monoenergetic proton beams from the interaction of a CO{sub 2} laser with a gaseous target

A monoenergetic proton beam is observed from the interaction of a short-pulse infrared ({lambda} = 10.6 {mu}m) laser at intensity I = 6 x 10{sup 15} W cm{sup -2} with a gas jet target. The proton beam is found to have narrow energy spread ({approx} 4% ), high spectral brightness ({approx} 10{sup 12} protons/MeV/sr), low normalized emittance ({epsilon}{sub n{approx_equal}} 8 nm rad), and high contrast (> 200 x over noise). The narrow energy spread and low levels of impurity makes this method an interesting route for high-repetition rate high quality proton beam production.

73 NUCLEAR PHYSICS AND RADIATION PHYSICS↗

A novel high resolution ion wide angle spectrometer

A novel ion wide angle spectrometer (iWASP) has been developed, which is capable of measuring angularly resolved energy distributions of protons and a second ion species, such as carbon C{sup 6+}, simultaneously. The energy resolution for protons and carbon ions is better than 10% at {approx}50 MeV/nucleon and thus suitable for the study of novel laser-ion acceleration schemes aiming for ultrahigh particle energies. A wedged magnet design enables an acceptance angle of 30 deg. ({approx}524 mrad) and high angular accuracy in the {mu}rad range. First, results obtained at the LANL Trident laser facility are presented demonstrating high energy and angular resolution of this novel iWASP.

46 INSTRUMENTATION RELATED TO NUCLEAR SCIENCE AND ↗