Engineering Papers⌕ Search

SEARCH · Engineering Papers

Results for “Quantum sensor”

Search indexed NASA NTRS and DOE OSTI research on propulsion, heat transfer, battery materials and energy systems. Follow report and document links to the original sources.

Quote a phrase for an exact phrase match. Source license links do not imply unrestricted reuse.

At least 433 records · Page 24

Wide Dynamic Range, 10 kHz Framing Detector for 4D-STEM

Hybrid pixel array detectors (PADs) have expanded the fidelity, frame rate and dynamic range for diffractive imaging in electron microscopes. With their high detective quantum efficiencies (DQE), the noise performance limited is by counting statistics. Consequently, improving the precision and quality of high-speed images requires increasing the linear dynamic range and the maximum usable beam current. Here we describe a new prototype hybrid PAD, our next-generation electron microscope pixel array detector (NG-EMPAD) that expands both the framing speed and dynamic range of our earlier EMPAD design. Like the EMPAD, electrons are detected directly in a 500 μm thick silicon sensor bonded pixel-by-pixel to a custom signal processing integrated circuit (IC). Each pixel in the IC integrates charge carriers produced by the high-energy incident electrons. Here, in-pixel circuitry uses a combination of techniques to extend the dynamic range, including adaptive gain switching and the quantitative excess charge dumping similar to the EMPAD. In-pixel buffering of signals during readout allows acquiring a new image while reading out the previously collected image, yielding an image collection duty cycle of nearly 100%.

36 MATERIALS SCIENCE↗

Development of quantum dot materials for infrared cameras (Final CRADA Report)

The aim of this project was to develop scalable methods to produce infrared (IR) mercury telluride (HgTe) colloidal quantum dot (CQD) thin films and demonstrate their utility in a proof-of-concept monolithic SWIR focal plane array (FPA). These objectives were accomplished by scaling up the HgTe CQD synthesis, characterizing physical and electrical properties of HgTe CQDs, evaluating solution-processed coating methods for quality and efficiency, and developing a process flow to integrate HgTe CQDs with commercial-off-the-shelf silicon CMOS readout circuits by solution-processed coating to produce monolithic FPAs. The FPA is the image sensor in an infrared imaging system responsible for detecting and processing reflected or emitted light into an infrared image of the scene under observation. The quality of the image is determined by the sensitivity and resolution of the image sensor in the system. Higher resolution IR FPAs enable higher throughput in manufacturing quality assurance, wider field of view for autonomous navigation, and longer range surveillance for defense.

77 NANOSCIENCE AND NANOTECHNOLOGY↗

Signal formation and sharing in AC-LGADs using the ALTIROC 0 front-end chip

The development of detectors that provide high resolution in four dimensions has attracted wide-spread interest in the scientific community for applications in high-energy physics, nuclear physics, medical imaging, mass spectroscopy as well as quantum information. However, finding a technology capable of fulfilling such aspiration proved to be an arduous task. Among other silicon-based candidates, the Low-Gain Avalanche Diode (LGAD) has already shown excellent timing performances but proved to be unsuitable for fine pixelization. Therefore, the AC-coupled LGAD (AC-LGAD) approach was introduced to provide high resolution in both time and space, making it a promising candidate for future 4D detectors. However, appropriate readout electronics must be developed to match the sensor's fast-time and fine-pitch capabilities. This is currently a major technological challenge. Here, we test AC-LGAD prototypes read out by the fast-time ASIC ALTIROC 0, originally developed for the readout of DC-coupled LGADs for the ATLAS experiment at the High Luminosity-LHC. Signal generated by either betas from a 90 Sr source or a focused infra-red laser were analyzed. This paper details the first successful readout of an AC-LGAD sensor using a readout chip. This result will pave the way for the design and construction of a new generation of AC-LGAD-based 4D detectors.

46 INSTRUMENTATION RELATED TO NUCLEAR SCIENCE AND ↗

Optimization of X-ray event screening using ground and in-orbit data for the Resolve instrument onboard the XRISM satellite

The X-Ray Imaging and Spectroscopy Mission (XRISM) satellite was successfully launched and put into a low-Earth orbit on September 6, 2023 (UT). The Resolve instrument onboard XRISM hosts an X-ray microcalorimeter detector, which was designed to achieve a high-resolution ( ≤ 7 eV FWHM at 6 keV), high-throughput, and non-dispersive spectroscopy over a wide energy range. It also excels in a low background with a requirement of < 2 × 10 -3 s -1 keV -1 (0.3 to 12.0 keV), which is equivalent to only one background event per spectral bin per 100-ks exposure. Event screening to discriminate X-ray events from background is a key to meeting the requirement. We present the result of the Resolve event screening using data sets recorded on the ground and in orbit based on the heritage of the preceding X-ray microcalorimeter missions, in particular, the Soft X-ray Spectrometer onboard ASTRO-H. We optimize and evaluate 19 screening items of three types based on (1) the event pulse shape, (2) relative arrival times among multiple events, and (3) good time intervals. We show that the initial screening, which is applied for science data products in the performance verification phase, reduces the background rate to 1.8 × 10 -3 s -1 keV -1 meeting the requirement. We further evaluate the additional screening utilizing the correlation among some pulse shape properties of X-ray events and show that it further reduces the background rate, particularly in the < 2 keV band. Over 0.3 to 12 keV, the background rate becomes 1.0 × 10 -3 s -1 keV -1 .

47 OTHER INSTRUMENTATION↗

System and method for measuring fluid properties using magnetic field techniques via magnetic tracer

A method and apparatus for determining a property of a fluid in a vessel. The method uses magnetic tracer particles and an externally applied magnetic field which orients the particles. When the fluid moves, it changes the orientation of the tracer particles, thus changing the magnetic fields. These changes are detected by external magnetic field sensors. By using mathematical models, the property of the fluid in the vessel is determined from the detected magnetic field. In this manner, fluid vorticity, velocity, strain and stress may be estimated.

42 ENGINEERING↗

Solution-Deposited and Patternable Conductive Polymer Thin-Film Electrodes for Microbial Bioelectronics

Microbial bioelectronic devices integrate naturally occurring or synthetically engineered electroactive microbes with microelectronics. These devices have a broad range of potential applications, but engineering the biotic–abiotic interface for biocompatibility, adhesion, electron transfer, and maximum surface area remains a challenge. Prior approaches to interface modification lack simple processability, the ability to pattern the materials, and/or a significant enhancement in currents. We report a novel conductive polymer coating that significantly enhances current densities relative to unmodified electrodes in microbial bioelectronics is reported. The coating is based on a blend of poly(3,4-ethylenedioxythiophene)-poly(styrenesulfonate) (PEDOT:PSS) crosslinked with poly(2-hydroxyethylacrylate) (PHEA) along with a thin polydopamine (PDA) layer for adhesion to an underlying indium tin oxide (ITO) electrode. When used as an interface layer with the current-producing bacterium Shewanella oneidensis MR-1, this material produces a 178-fold increase in the current density compared to unmodified electrodes, a current gain that is higher than previously reported thin-film 2D coatings and 3D conductive polymer coatings. The chemistry, morphology, and electronic properties of the coatings are characterized and the implementation of these coated electrodes for use in microbial fuel cells, multiplexed bioelectronic devices, and organic electrochemical transistor based microbial sensors are demonstrated. It is envisioned that this simple coating will advance the development of microbial bioelectronic devices.

patterned bioelectronics↗

Electro-optical measurement of intense electric field on a high energy pulsed power accelerator

We describe a direct electro-optical approach to measuring a strong 118 MV/m narrow pulse width (~ 33 ns) electric field in the magnetically insulated transmission line (MITL) of a pulsed power accelerator. To date, this is the highest direct external electric field measured electro-optically in a pulsed power accelerator, and it is between two to three orders of magnitude higher than values reported in comparable high energy scientific experiments. The MITL electric field is one of the most important operating parameters in an accelerator and is critical to understanding the properties of the radiation output. However, accurately measuring these high fields using conventional pulsed power diagnostics is difficult due to the strength of interfering particles and fields. Our approach uses a free-space laser beam with a dielectric crystal sensor that is highly immune to electromagnetic interference and does not require an external calibration. Here we focus on device theory, operating parameters, laboratory and pulsed power accelerator experiments as well as challenges that were overcome in the measurement environment.

71 CLASSICAL AND QUANTUM MECHANICS, GENERAL PHYSIC↗

Gradient Field Detection Using Interference of Stimulated Microwave Optical Sidebands

Here, we demonstrate that stimulated microwave optical sideband generation using parametric frequency conversion can be utilized as a powerful technique for coherent state detection in atomic physics experiments. The technique has advantages over traditional absorption or polarization rotation-based measurements and enables the isolation of signal photons from probe photons. We outline a theoretical framework that accurately models sideband generation using a density matrix formalism. Using this technique, we demonstrate a novel intrinsic magnetic gradiometer that detects magnetic gradient fields between two spatially separated vapor cells by measuring the frequency of the beat note between sidebands generated within each cell. The sidebands are produced with high efficiency using parametric frequency conversion of a probe beam interacting with 87 Rb atoms in a coherent superposition of magnetically sensitive hyperfine ground states. Interference between the sidebands generates a low-frequency beat note whose frequency is determined by the magnetic field gradient between the two vapor cells. In contrast to traditional gradiometers the intermediate step of measuring the magnetic field experienced by the two vapor cells is unnecessary. We show that this technique can be readily implemented in a practical device by demonstrating a compact magnetic gradiometer sensor head with a sensitivity of 25 fT/cm/ √ Hz with a 4.4 cm baseline, while operating in a noisy laboratory environment unshielded from Earth’s field.

74 ATOMIC AND MOLECULAR PHYSICS↗

Magneto-Optical Sensing Beyond the Shot Noise Limit

Magneto-optical sensors including spin noise spectroscopies and magneto-optical Kerr effect microscopies are now ubiquitous tools for materials characterization that can provide new understanding of spin dynamics, hyperfine interactions, spin-orbit interactions, and charge-carrier g-factors. Both interferometric and intensity-difference measurements can provide photon-shot-noise-limited sensitivity, but further improvements in sensitivity with classical resources require either increased laser power that can induce unwanted heating and electronic perturbations or increased measurement times that can obscure out-of-equilibrium dynamics and slow experimental throughput. Proof-of-principle measurements have already demonstrated quantum enhanced spin noise measurements with a squeezed readout field that are likely to be critical to the nonperturbative characterization of spin excitations in quantum materials that emerge at low temperatures. Here, a truncated nonlinear interferometric readout for low-temperature magneto-optical Kerr effect and related magneto-optical microscopies that is accessible with today's quantum optical resources is proposed. 10 nrad/$\sqrt{Hz}$ sensitivity is achievable with optical power as small as 1 µW. As a result, measurements may be performed at temperatures as low as 83 mK in commercially available dilution refrigerators. This combination of high sensitivity and low operating temperature is impossible to achieve with any classical measurement. The quantum advantage for the proposed measurements persists even in the limit of large loss and small squeezing parameters.

71 CLASSICAL AND QUANTUM MECHANICS, GENERAL PHYSIC↗

Floquet Gauge Pumps as Sensors for Spectral Degeneracies Protected by Symmetry or Topology

We introduce the concept of a Floquet gauge pump whereby a dynamically engineered Floquet Hamiltonian is employed to reveal the inherent degeneracy of the ground state in interacting systems. We demonstrate this concept in a one-dimensional XY model with periodically driven couplings and transverse field. In the high-frequency limit, we obtain the Floquet Hamiltonian consisting of the static XY and dynamically generated Dzyaloshinsky-Moriya interaction (DMI) terms. The dynamically generated magnetization current depends on the phases of complex coupling terms, with the XY interaction as the real and DMI as the imaginary part. As these phases are cycled, the current reveals the ground-state degeneracies that distinguish the ordered and disordered phases. In conclusion, we discuss experimental requirements needed to realize the Floquet gauge pump in a synthetic quantum spin system of interacting trapped ions.

74 ATOMIC AND MOLECULAR PHYSICS↗

Ultra-compact Imaging Technology (CRADA Final Report)

As part of the Cyclotron Road program, Synopic (formerly FlatCam LLC) sought to investigate the benefits of its depth-sensitive imaging techniques. The basic principle involved using a thin mask specially designed to encode light reaching a sensor, in conjunction with optimized computational algorithms, in such a manner that allowed for both miniaturization of imaging systems and improved computation toward high resolution, three-dimensional imaging. By thoroughly exploring the resolution, mask/optical design, and algorithmic capabilities of our depth sensitive technology, we expand the potential applications for (but not limited to) medical, consumer and industrial purposes. The project aimed to develop new imaging systems by building on previous work and using 1) materials capable of modulating and 2) sensors capable of measuring visible and longer wavelengths. Preliminary research was conducted to design, fabricate and characterize imaging systems with the goal of improving resolution, enhancing single capture, three-dimensional imaging, and extending depth of field of captured images. The primary goal was to determine whether adapting the depth-sensitive imaging system is feasible, and early results are promising.

71 CLASSICAL AND QUANTUM MECHANICS, GENERAL PHYSIC↗

Direct experimental constraints on the spatial extent of a neutrino wavepacket

Despite their high relative abundance in our Universe, neutrinos are the least understood fundamental particles of nature. In fact, the quantum properties of neutrinos emitted in experimentally relevant sources are theoretically contested and the spatial extent of the neutrino wavepacket is only loosely constrained by reactor neutrino oscillation data with a spread of 13 orders of magnitude. Here we present a method to directly access this quantity by precisely measuring the energy width of the recoil daughter nucleus emitted in the radioactive decay of beryllium-7. The final state in the decay process contains a recoiling lithium-7 nucleus, which is entangled with an electron neutrino at creation. The lithium-7 energy spectrum is measured to high precision by directly embedding beryllium-7 radioisotopes into a high-resolution superconducting tunnel junction that is operated as a cryogenic sensor. Under this approach, we set a lower limit on the Heisenberg spatial uncertainty of the recoil daughter of 6.2 pm, which implies that the final-state system is localized at a scale more than a thousand times larger than the nucleus itself. From this measurement, the first, to our knowledge, direct lower limit on the spatial extent of a neutrino wavepacket is extracted. These results may have implications in several areas including the theoretical understanding of neutrino properties, the nature of localization in weak nuclear decays and the interpretation of neutrino physics data.

71 CLASSICAL AND QUANTUM MECHANICS, GENERAL PHYSIC↗

NanoMechanics: Elasticity and Friction in Nano‐Objects

A large scientific and technological effort is underway to investigate the properties of two‐dimensional (2D) materials to become building blocks in integrated nano‐electronic and photonic circuits, composites, coatings, energy harvesting nano‐ systems, nano‐sensors, and nano‐electro‐mechanical systems (NEMS).While several experiments and calculations have revealed exciting novel phenomena in these nanostructures, many scientific and technological questions remain open. In particular, understanding and controlling the structure and mechanical properties of 2D materials at the interface with a solid surface is of key importance to enable the aforementioned nanotechnologies, as well as to fulfill the potential of strain engineering to tailor their properties. The vision of this DoE research program was to investigate novel mechanical properties and phenomena in 1D and 2D materials with the overarching goal of defining a new basic understanding of mechanical behavior in nano and quantum systems. The group of the PI has developed in the last years several studies on the mechanical properties of Carbon nanotubes and oxide nanobelts, more recently the PI has focused her attention on the properties of two‐dimensional materials, such as graphene and MoS 2 , which are a few‐atomic‐layer thick films and hold a great potential for technological and energy applications. The most studied 2D material is graphene, existing as a single layer of graphite or a few‐layer thick epitaxial graphene film. Graphene possesses a large in‐plane Young’s modulus as well as high intrinsic carrier mobility, and high in‐plane thermal conductivity. Besides graphene, also 2D films of graphene oxide (GO), hexagonal Boron Nitride (h‐BN), and transition metal dichalcogenides such as MoS 2 exhibit unique and excellent properties and hold great promise for nanotechnology applications. This research program was aimed at developing a new basic understanding of the mechanical properties of 1D and 2D materials at the interface with solid substrates, with a focus on the role of defects, materials structure, and substrate interaction. Ultimately, we aimed at developing the basic knowledge and experimental tools for manipulating 1D and 2D materials’ structure, stacking, substrate interaction, defects, and number of layers to realize an entirely new class of ultra‐hard, ultra‐thin, and ultra‐light active materials with ad‐ hoc mechanical properties for a variety of applications.

2D Materials↗

Deep Learning Approach for High-accuracy Electron Counting of Monolithic Active Pixel Sensor-type Direct Electron Detectors at Increased Electron Dose

Abstract Electron counting can be performed algorithmically for monolithic active pixel sensor direct electron detectors to eliminate readout noise and Landau noise arising from the variability in the amount of deposited energy for each electron. Errors in existing counting algorithms include mistakenly counting a multielectron strike as a single electron event, and inaccurately locating the incident position of the electron due to lateral spread of deposited energy and dark noise. Here, we report a supervised deep learning (DL) approach based on Faster region-based convolutional neural network (R-CNN) to recognize single electron events at varying electron doses and voltages. The DL approach shows high accuracy according to the near-ideal modulation transfer function (MTF) and detector quantum efficiency for sparse images. It predicts, on average, 0.47 pixel deviation from the incident positions for 200 kV electrons versus 0.59 pixel using the conventional counting method. The DL approach also shows better robustness against coincidence loss as the electron dose increases, maintaining the MTF at half Nyquist frequency above 0.83 as the electron density increases to 0.06 e−/pixel. Thus, the DL model extends the advantages of counting analysis to higher dose rates than conventional methods.

Materials Science↗

Inverse Methods - Users Manual 5.8

The inverse methods team provides a set of tools for solving inverse problems in structural dynamics and thermal physics, and also sensor placement optimization via Optimal Experimental Design (OED). These methods are used for designing experiments, model calibration, and verification/validation analysis of weapons systems. This document provides a user’s guide to the input for the three apps that are supported for these methods. Details of input specifications, output options, and optimization parameters are included.

71 CLASSICAL AND QUANTUM MECHANICS, GENERAL PHYSIC↗

Listening for new physics with quantum acoustics

We present a novel application of a qubit-coupled phonon detector to search for new physics, e.g., ultralight dark matter (DM) and high-frequency gravitational waves. The detector, motivated by recent advances in quantum acoustics, is composed of superconducting transmon qubits coupled to high-overtone bulk acoustic resonators (ℎ⁡BARs) and operates in the GHz−10 GHz frequency range. New physics can excite 𝒪⁡(10 μ⁢eV) phonons within the ℎ⁡BAR, which are then converted to qubit excitations via a transducer. We detail the design, operation, backgrounds, and expected sensitivity of a prototype detector, as well as a next-generation detector optimized for new physics signals. We find that a future detector can complement current haloscope experiments in the search for both dark photon DM and high-frequency gravitational waves. Lastly, we comment on such a detector’s ability to operate as a 𝒪⁡(10 μ⁢eV) athermal phonon sensor for sub-GeV DM detection.

46 INSTRUMENTATION RELATED TO NUCLEAR SCIENCE AND ↗

Surface Pressure Fluctuations Induced by a Hypersonic Turbulent Boundary Layer on a Sharp Cone at Angle of Attack

High-fidelity simulations are performed to characterize the turbulence-induced wall pressure fluctuations on a sharp cone at a 5.5° angle-of-attack in a Mach 8 flow. Wall-resolved large-eddy simulation (LES) and wall-modeled large-eddy simulation (WMLES) results are compared to measurements at several locations on the cone body, where comparisons with high-frequency PCB sensors are good, while comparison with low-frequency kulite sensors varies depending on the location. For a given streamwise location, simulation results show significant azimuthal variation in the wall pressure fluctuation statistics. Comparisons between LES and WMLES results indicate that WMLES can accurately reproduce the low-frequency component of the autospectra quite well, while slight sensitivity is apparent in the coherence. A grid sensitivity study for WMLES further demonstrated sensitivity in the wall pressure fluctuation coherence, but not in the autospectra.

71 CLASSICAL AND QUANTUM MECHANICS, GENERAL PHYSIC↗