Engineering Papers⌕ Search

SEARCH · Engineering Papers

Results for “QUARTZ”

Search indexed NASA NTRS and DOE OSTI research on propulsion, heat transfer, battery materials and energy systems. Follow report and document links to the original sources.

Quote a phrase for an exact phrase match. Source license links do not imply unrestricted reuse.

At least 433 records · Page 24

Vacuum Ultraviolet Radiation Desorption of Molecular Contaminants Deposited on Quartz Crystal Microbalances

Recent quartz crystal microbalance measurements made in the Marshall Space Flight Center, Photo-Deposition Facility, for several materials, recorded a significant loss of deposited contaminants when the deposition surface of the microbalance was illuminated by a deuterium lamp. These measurements differ from observations made by other investigators in which the rate of deposition increased significantly when the deposition surface was illuminated with vacuum ultraviolet radiation. These observations suggest that the accelerated deposition of molecular contaminants on optically sensitive surfaces is dependant upon the contaminant being deposited and must be addressed during the materials selection process by common material screening techniques.

Albyn, Keith↗

In-Flight Performance of the Cassini Hemispherical Quartz Resonator Gyro Inertial Reference Units

The Cassini-Huygens mission is a flagship class NASA/ESA mission to the planet Saturn. Launched in 1997, Cassini is still successfully operating after 16 years of flight and the telemetry from the attitude control hardware on Cassini has produced an immense dataset that allows the Cassini operations team to report on the long-term performance of several commercially available GNC hardware components in the space environment. This investigation summarizes the in-flight performance of the two inertial reference units aboard Cassini. Each of the two Cassini inertial reference units contains four hemispherical quartz resonator gyros. The Cassini operations team previously reported on the performance of the inertial reference units in 2007, and this paper provides an update with an additional 6 years of flight experience at Saturn.

guidance, navigation, and control (GNC)↗

Development of an Ablative 3D Quartz / Cyanate Ester Composite for the Orion Spacecraft Compression Pad

With the successful flight test of the Orion Multipurpose Crew Vehicle last December, NASA is well on its way to sending humans into deep space with the goal of putting astronauts on Mars in the 2030s. Orion will receive some upgrades for its next launch in 2018 including a newly developed 3D Quartz Cyanate Ester composite material for the compression pad. The compression pads are 10-inches in diameter and 3-inches thick. The pucks are at 4 locations in the heat shield that serve as a part of the mechanism for holding the Crew and Service modules together during most mission phases prior to separation followed by Earth re-entry. Thus the compression pad has structural, aerothermal and thermal protection requirements.This paper describes the approach used for developing the new 3D composite, including continuous 3D weaving on an automated loom followed by resin transfer molding. Mechanical, thermal and arc jet testing of the 3D composite are also described.

Feldman, Jay↗

Development of an Ablative 3D Quartz / Cyanate Ester Composite for the Orion Spacecraft Compression Pad

With the successful flight test of the Orion Multipurpose Crew Vehicle last December, NASA is well on its way to sending humans into deep space with the ultimate goal of putting astronauts on Mars in the 2030s. Orion will receive some upgrades for its next launch in 2018 including a newly developed 3D quartz / cyanate ester composite material for the compression pad. Multiple pad locations in the heat shield serve as a part of the mechanism for holding the Crew and Service Modules together during most mission phases prior to separation followed by Earth re-entry of the Crew Module. Thus the compression pad must survive structural and aerothermal loads, and protect the adjascent structure and heat shield materials from over-heating.This paper describes the approach used for developing the new 3D composite, including continuous 3D weaving on an automated loom followed by resin transfer molding. Mechanical, thermal, arc jet ,and stress relaxation testing of the 3D composite are also described.

Feldman, Jay D.↗

A Method for Incorporating Quartz Crystal Microbalance Thermo-Gravimetric Assessment Data in Contamination Modeling

The science objectives of increasingly ambitious space missions require meeting stringent contamination requirements. Contamination transport models are based on established principles such as Fick’s law for contamination diffusion within the source material, Arrhenius factors to account for temperature variations and free molecular transport for spacecraft operating in vacuum. In addition to the science principles, empirical data obtained from ASTM E1559 testing is used for engineering contamination modeling. The ASTM E1559 test provides outgassing rate data for materials at expected spacecraft temperatures during a mission. Multiple quartz crystal microbalances (QCMs) can be operated at different temperatures to measure the amount of contamination condensation that can occur on various spacecraft surfaces. At the conclusion of the ASTM E1559 test a thermo-gravimetric assessment (TGA) can be performed by heating the QCMs at a linear rate to obtain contamination desorption data. This TGA data provides a wealth of information that can be incorporated into contamination models. A method for applying this data is presented.

Anderson, John R↗

Low-cost scalable quartz crystal microbalance array for environmental sensing

Proliferation of environmental sensors for internet of things (IoT) applications has increased the need for low-cost platforms capable of accommodating multiple sensors. Quartz crystal microbalance (QCM) crystals coated with nanometer-thin sensor films are suitable for use in high-resolution (~1 ng) selective gas sensor applications. We demonstrate a scalable array for measuring frequency response of six QCM sensors controlled by low-cost Arduino microcontrollers and a USB multiplexer. Gas pulses and data acquisition were controlled by a LabVIEW user interface. We test the sensor array by measuring the frequency shift of crystals coated with different compositions of polymer composites based on poly(3,4-ethylenedioxythiophene):polystyrene sulfonate (PEDOT:PSS) while films are exposed to water vapor and oxygen inside a controlled environmental chamber. Our sensor array exhibits comparable performance to that of a commercial QCM system, while enabling high-throughput 6 QCM testing for under $1,000. We use deep neural network structures to process sensor response and demonstrate that the QCM array is suitable for gas sensing, environmental monitoring, and electronic-nose applications.

Anazagasty, Cristain↗

Liquid-Phase Quartz Crystal Microbalance for Photovoltaics Research (Presentation)

The construction of a new QCM-based flow reactor has been completed. Initial results include: (1) stable oscillation achieved with crystals sputter coated at 200 C with 500 nm ZnO; (2) sub-Hz noise level means << monolayer sensitivity; (3) Operation at elevated temperature possible after installation of membrane contactors; (4) determination of ZnO etch rates using dilute ethanolic NH{sub 4}Cl; (5) demonstration of use of an etchant as a probe of oxide-molecule interactions; (6) and use in flow rate-dependent CdS chemical deposition.

14 SOLAR ENERGY↗

Quartz-based flat-crystal resonant inelastic x-ray scattering spectrometer with sub-10 meV energy resolution

Continued improvement of the energy resolution of resonant inelastic x-ray scattering (RIXS) spectrometers is crucial for fulfilling the potential of this technique in the study of electron dynamics in materials of fundamental and technological importance. In particular, RIXS is the only alternative tool to inelastic neutron scattering capable of providing fully momentum resolved information on dynamic spin structures of magnetic materials, but is limited to systems whose magnetic excitation energy scales are comparable to the energy resolution. The state-of-the-art spherical diced crystal analyzer optics provides energy resolution as good as 25 meV but has already reached its theoretical limit. For this study, we demonstrate a novel sub-10 meV RIXS spectrometer based on flat-crystal optics at the Ir-L3 absorption edge (11.215 keV) that achieves an analyzer energy resolution of 3.9 meV, very close to the theoretical value of 3.7 meV. In addition, the new spectrometer allows efficient polarization analysis without loss of energy resolution. The performance of the instrument is emonstrated using longitudinal acoustical and optical phonons in diamond, and magnon in Sr 3 Ir 2 O 7 . The novel sub-10 meV RIXS spectrometer thus provides a window into magnetic materials with small energy scales.

36 MATERIALS SCIENCE↗

Development of a quartz tuning-fork-based force sensor for measurements in the tens of nanoNewton force range during nanomanipulation experiments

Understanding the mechanical properties of nanoscale systems requires new experimental and theoretical tools. In particular, force sensors compatible with nanomechanical testing experiments and with sensitivity in the nN range are required. Here, we report the development and testing of a tuning-fork-based force sensor for in situ nanomanipulation experiments inside a scanning electron microscope. The sensor uses a very simple design for the electronics and it allows the direct and quantitative force measurement in the 1–100 nN force range. The sensor response is initially calibrated against a nN range force standard, as, for example, a calibrated Atomic Force Microscopy cantilever; subsequently, applied force values can be directly derived using only the electric signals generated by the tuning fork. Using a homemade nanomanipulator, the quantitative force sensor has been used to analyze the mechanical deformation of multi-walled carbon nanotube bundles, where we analyzed forces in the 5–40 nN range, measured with an error bar of a few nN.

46 INSTRUMENTATION RELATED TO NUCLEAR SCIENCE AND ↗

Structure and vibrations of different charge Ge impurity in α-quartz

Atomic structure and localized vibrations of α‐SiO{sub 2}:Ge are studied using computer modeling techniques. The simulation was carried out by the lattice dynamics calculation of the local density of vibrational states. Local structures parameters are calculated, localized symmetrized vibrations frequency caused by Ge impurity in different charge states are defined. The movements of atoms located near Ge impurity are analyzed and their contribution into localized vibrations of different type is evaluated.

75 CONDENSED MATTER PHYSICS, SUPERCONDUCTIVITY AND↗

Thermodynamic parameters for mixtures of quartz under shock wave loading in views of the equilibrium model

The numerical results of modeling of shock wave loading of mixtures with the SiO{sub 2} component are presented. The TEC (thermodynamic equilibrium component) model is employed to describe the behavior of solid and porous multicomponent mixtures and alloys under shock wave loading. State equations of a Mie–Grüneisen type are used to describe the behavior of condensed phases, taking into account the temperature dependence of the Grüneisen coefficient, gas in pores is one of the components of the environment. The model is based on the assumption that all components of the mixture under shock-wave loading are in thermodynamic equilibrium. The calculation results are compared with the experimental data derived by various authors. The behavior of the mixture containing components with a phase transition under high dynamic loads is described.

36 MATERIALS SCIENCE↗

Performance comparison of Rayleigh and STW modes on quartz crystal for strain sensor application

In this study, we compare two kinds of strain sensors based on Rayleigh wave and surface transverse wave (STW) modes, respectively. First, we perform a strain-and-stress analysis using the finite element method, and we consider the contribution to a surface acoustic wave (SAW) velocity shift. Prior to fabrication, we use a coupling-of-modes model to simulate and optimize two-port SAW resonators for both modes. We use a network analyzer to measure and characterize the two devices. Further, we perform an experiment using a strain-testing system with a tapered cross-section cantilever beam. The experimental results show that the ratio of the frequency shift to the strain for the Rayleigh wave mode is −1.124 ppm/με in the parallel direction and 0.109 ppm/με in the perpendicular direction, while the corresponding values for the STW mode are 0.680 ppm/με and 0.189 ppm/με, respectively.

71 CLASSICAL AND QUANTUM MECHANICS, GENERAL PHYSIC↗